ETC G3CN-DX02P-US

Solid-state Relay
G3CN
PCB-mounting SSR for FA Equipment
Requiring High Reliability
Wide I/O voltage range: 3 to 28 VDC input and 75 to
264 VAC output or 3 to 28 VDC input and 3 to
52.8 VDC output.
Two load currents available: 2 A and 3 A
Flat and vertical models available for a variety of
applications.
Approved by UL and CSA.
RC
Ordering Information
Isolation
Photocoupler
Zero cross
function
Yes
Indicator
No
Rated output voltage
(Applicable output load)
2 A at 100 to 240 VAC
(2 A at 75 to 264 VAC)
Rated input voltage
4 to 24 VDC
Model
G3CN-202P-US
G3CN-202P1-US*
3 A at 100 to 240 VAC
(3 A at 75 to 264 VAC)
G3CN-203P-US
G3CN-203P1-US*
Phototriac
No
2 A at 100 to 240 VAC
(2 A at 75 to 264 VAC)
5, 12, 24 VDC**
G3CN-202PL-US
G3CN-202PL1-US*
3 A at 100 to 240 VAC
(3 A at 75 to 264 VAC)
G3CN-203PL-US
G3CN-203PL1-US*
Photocoupler
---
2 A at 4 to 48 VDC
(2 A at 3 to 52.8 VDC)
4 to 24 VDC
G3CN-DX02P-US
G3CN-DX02P1-US*
3 A at 4 to 48 VDC
(3 A at 3 to 52.8 VDC)
G3CN-DX03P-US
G3CN-DX03P1-US*
*Vertical models.
**When ordering, specify the input voltage
171
G3CN
G3CN
Specifications
Ratings
Input
Model
Rated voltage
Operating voltage
Impedance
Voltage level
Must operate
voltage
G3CN-202P(1)-US
G3CN-203P(1)-US
4 to 24 VDC
3 to 28 VDC
1.5 kΩ +20%/–10%
3 VDC max.
G3CN-202PL(1)-US
G3C
0
( ) US
G3CN 203PL(1) US
G3CN-203PL(1)-US
5 VDC
4 to 6 VDC
390 Ω±20%
4 VDC max.
12 VDC
9.6 to 14.4 VDC
900 Ω±20%
9.6 VDC max.
24 VDC
19.2 to 28.8 VDC
2 kΩ±20%
19.2 VDC max.
4 to 24 VDC
3 to 28 VDC
1.5 kΩ +20%/–10%
3 VDC max.
G3CN-DX02P(1)-US
G3CN-DX03P(1)-US
Note:
Must release
voltage
1 VDC min.
The input impedance is measured at the maximum value of the operating voltage. For example, with the model rated at 4 to 24 VDC, the
input impedance is measured at 28 VDC.
Output
Model
Applicable load
Rated load voltage
Load volage range
Load current
Inrush current
Without heat sink
G3CN-202P(1)-US
G3CN-202PL(1)-US
100 to 240 VAC
75 to 264 VAC
G3CN-203P(1)-US
G3CN-203PL(1)-US
G3CN-DX02P(1)-US
4 to 48 VDC
3 to 52.8 VDC
G3CN-DX03P(1)-US
0.1 to 2 A
30 A (60 Hz, 1 cycle)
0.1 to 3 A
45 A (60 Hz, 1 cycle)
0.1 to 2 A
12 A (10 ms)
0.1 to 3 A
18 A (10 ms)
Characteristics
Item
G3CN-202P(1)/203P(1)-US
G3CN-202PL(1)/203PL(1)-US
G3CN-DX02P(1)/03P(1)-US
Operate time
1/2 of load power source cycle +
1 ms max.
1 ms max.
0.5 ms max.
Release time
1/2 of load power source cycle +
1 ms max.
1/2 of load power source cycle
+ 1 ms max.
2 ms max.
Output ON voltage drop
1.6 V (RMS) max.
Leakage current
5 mA max. (at 100 VAC)
10 mA max. (at 200 VAC)
Insulation resistance
100 MΩ min. (at 500 VDC)
Dielectric strength
2,500 VAC, 50/60 Hz for 1 min
Vibration resistance
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
Malfunction: 1,000 m/s2
Ambient temperature
Operating: –30°C to 80°C (with no icing nor condensation)
Storage: –30°C to 100°C (with no icing nor condensation)
Ambient humidity
Operating: 45% to 85%
Approved standards
UL508, UL114 File No.E64562, CSA C22.2 (No.0, No.14) File No. LR35535
Weight
Approx. 25 g
172
1.5 V max.
2.5 mA max. (at 100 VAC)
5 mA max. (at 200 VAC)
5 mA max. (at 50 VDC)
G3CN
G3CN
Engineering Data
Load Current vs. Ambient Temperature Characteristics
G3CN-203P(1)/-203PL(1)/-DX03P(1)-US
Load current (A)
Load current (A)
G3CN-202P(1)/-202PL(1)/-DX02P(1)-US
Ambient temperature (°C)
Ambient temperature (°C)
Inrush Current Resistivity
Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.)
G3CN-DX02P(1)-US
Inrush current (A. Peak)
Inrush current (A. Peak)
G3CN-202P(1)/-202PL(1)-US
Energizing time (ms)
G3CN-DX03P(1)-US
Inrush current (A. Peak)
Inrush current (A. Peak)
G3CN-203P(1)/-203PL(1)-US
Energizing time (ms)
Energizing time (ms)
Energizing time (ms)
173
G3CN
G3CN
Dimensions
Note:
All units are in millimeters unless otherwise indicated.
Flat Model
33 max.
G3CN-20jP/-20jPL/-DX0jP
Terminal Arrangement/
Mounting Holes
(Bottom View)
25 max.
Four 1.2-dia.
holes
Two, 4 dia.
holes
25
12.5
10
14.5
20 max. max.
1.5 max.
Two, 2-dia.
holes
0.4
25±0.5
0.7
Terminal Arrangement/
Internal Connections
(Bottom View)
0.7
10±0.5
12.5±0.5
+
Input
voltage
3
1
+
(+)
Input
–
Load
(+)
Load power
supply
–
(–)
4
2
Note:
Vertical Model
Load
(–)
Values in parentheses apply
to the DC-load versions.
G3CN-20jP1/-20jPL1/-DX0jP1
33 max.
Terminal Arrangement/
Mounting Holes
(Bottom View)
14 max.
Two, 2-dia.
holes
Four 1.2-dia.
holes
Pattern
Pattern
5
26.5 max.
32 max.
1.5 max.
5±0.5
(17.5)
27.5
Terminal Arrangement/
Internal Connections
(Bottom View)
(17.5)
27.5±0.5
0.7
5±0.5
Input voltage
0.4
3±1
–
(–)
(+)
Load
3
–
2 1
+
Input
Note:
Load power supply
+
4
174
5
(–)
(+)
Load
Values in parentheses apply
to the DC-load versions.
G3CN
G3CN
Precautions
Refer to pages 11 to 19 for general precautions.
Connection
Protective Component
With the SSR for DC switching, the load can be connected to either
positive or negative output terminal of the SSR.
Since the SSR does not incorporate an overvoltage absorption
component, be sure to connect an overvoltage absorption component when using the SSR under an inductive load.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. K063-E1-2A
175