G3CN Solid State Relays PCB-mounting SSR for FA Equipment Requiring High Reliability • 3 to 28 VDC input and 75 to 264 VAC output. • Wide I/O voltage range: 3 to 28 VDC input and 3 to 52.8 VDC output. • Two load currents available: 2 A and 3 A • Flat and vertical models available for a variety of applications. • Lineup includes models with UL and CSA certification (model numbers ending in “-US”). RoHS Compliant Refer to "Solid State Relays Common Precautions". ■List of Models Isolation Zero cross function Indicator Rated output load Rated input voltage Model 2 A at 100 to 240 VAC Photocoupler Yes G3CN-202P1 4 to 24 VDC Phototriac No No 3 A at 100 to 240 VAC G3CN-203P1 5 VDC 12 VDC 24 VDC *2 2 A at 4 to 48 VDC − Photocoupler 10 pcs *1 G3CN-203P 3 A at 100 to 240 VAC 2 A at 100 to 240 VAC Minimum packing unit G3CN-202P 4 to 24 VDC 3 A at 4 to 48 VDC 20 pcs 10 pcs *1 20 pcs G3CN-202PL 10 pcs G3CN-202PL1 *1 20 pcs G3CN-203PL 10 pcs G3CN-203PL1 *1 20 pcs G3CN-DX02P 10 pcs G3CN-DX02P1 *1 20 pcs G3CN-DX03P 10 pcs G3CN-DX03P1 *1 20 pcs G 3 C N *1. These are vertical types. *2 When ordering, specify the input voltage. ■Ratings Input Item Voltage level Must operate voltage Must release voltage Rated voltage Operating voltage 4 to 24 VDC 3 to 28 VDC 1.5 kΩ +20%/−10% 3 VDC max. G3CN-202PL(1) G3CN-203PL(1) 5 VDC 12 VDC 24 VDC 4 to 6 VDC 9.6 to 14.4 VDC 19.2 to 28.8 VDC 390 Ω ±20% 900 Ω ±20% 2 kΩ ±20% 4 VDC max. 9.6 VDC max. 19.2 VDC max. G3CN-DX02P(1) G3CN-DX03P(1) 4 to 24 VDC 3 to 28 VDC 1.5 kΩ +20%/−10% 3 VDC max. Model G3CN-202P(1) G3CN-203P(1) Input impedance Output Item Model G3CN-202P(1) G3CN-202PL(1) G3CN-203P(1) G3CN-203PL(1) G3CN-DX02P(1) G3CN-DX03P(1) Rated load voltage 100 to 240 VAC 4 to 48 VDC Applicable load Load voltage range Load current Inrush current 0.1 to 2 A * 30 A (60 Hz, 1 cycle) 0.1 to 3 A * 45 A (60 Hz, 1 cycle) 0.1 to 2 A * 0.1 to 3 A * 12 A (10 ms) 18 A (10 ms) 1 VDC min. Note. The input impedance values are the maximum values of applied voltage. (measured at 28 VDC for 4 to 24 VDC models) 75 to 264 VAC 3 to 52.8 VDC * The load current varies depending on the ambient temperature. Refer to Load Current vs. Ambient Temperature under Engineering Data. ■Characteristics Model Operate time Release time Output ON voltage drop Item Leakage current Insulation resistance Dielectric strength Vibration resistance Shock resistance Ambient Operating temperature Ambient Operating humidity Storage Temperature Weight G3CN-202P(1), G3CN-203P(1) G3CN-202PL(1), G3CN-203PL(1) G3CN-DX02P(1), G3CN-DX03P(1) 1/2 of load power source cycle + 1 ms max. 1 ms max. 0.5 ms max. 1/2 of load power source cycle + 1 ms max. 1/2 of load power source cycle + 1 ms max. 2 ms max. 1.6 V (RMS) max. 1.5 V max. 5 mA max. (at 100 VAC) 2.5 mA max. (at 100 VAC) 5 mA max. (at 50 VDC) 10 mA max. (at 200 VAC) 5 mA max. (at 200 VAC) 100 MΩ min. (at 500 VDC) 2,500 VAC, 50/60 Hz for 1 min between input and output 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) 1,000 m/s2 −30°C to 80°C (with no icing nor condensation) 45% to 85%RH −30°C to 100°C (with no icing nor condensation) Approx. 25 g 1 G3CN Solid State Relays ■Engineering Data ● One Cycle Surge Current: Non-repetitive Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.) 2-A Load Model G3CN-202P(1), G3CN-202PL(1) 2 1.5 G3CN-DX02P(1) Inrush current (A. Peak) Inrush current (A. Peak) Load current (A) ● Load Current vs. Ambient Temperature Characteristics G3CN-202P(1), G3CN-202PL(1), G3CN-DX02P(1) 30 20 30 28 26 24 22 20 18 16 14 1 12 10 10 8 0.5 6 4 0 20 0 40 60 80 100 Ambient temperature (°C) 30 50 100 200 2 0 10 500 1,000 5,000 Energized time (ms) 3-A Load Model G3CN-203P(1), G3CN-203PL(1) 5 Inrush current (A. Peak) G 3 C N Load current (A) G3CN-203P(1), G3CN-203PL(1), G3CN-DX03P(1) 10 4 3 30 50 70100 200 300 500 1,000 2,000 Energized time (ms) G3CN-DX03P(1) Inrush current (A. Peak) 0 −30 −20 50 40 30 30 28 26 24 22 20 18 16 14 2 12 20 10 8 1 6 10 4 0 −30 −20 0 20 2 0 10 0 40 60 80 100 Ambient temperature (°C) 10 30 50 100 200 500 1,000 5,000 Energized time (ms) 30 50 70100 200 300 500 1,000 2,000 Energized time (ms) ■Dimensions (Unit: mm) ●Flat Model G3CN-20@P G3CN-20@PL G3CN-DX0@P 33 max. Terminal Arrangement/ Internal Connections (BOTTOM VIEW) Mounting Holes Tolerance: ±0.1 mm unless specified (BOTTOM VIEW) 25 max. Four 1.2-dia. holes 25 Two, 4 dia. + 10 14.5 max. 1.5 max. 12.5 Input voltage 1 3 20 max. − Pattern 0.4 0.7 Load (+) INPUT Load power supply LOAD − (−) 4 (+) (−) 4 Pattern Two, 2-dia. 25±0.5 3 3 + Note. The plus and minus symbols shown in the parentheses are for DC loads. 0.7 10±0.5 12.5±0.5 ●Vertical Model G3CN-20@P1 G3CN-20@PL1 G3CN-DX0@P1 33 max. Mounting Holes Tolerance: ±0.1 mm unless specified (BOTTOM VIEW) 14 max. − Four 1.2-dia. holes Two, 2-dia. Terminal Arrangement/ Internal Connections (BOTTOM VIEW) Input voltage + Load power supply (−) (+) 3 Load 3 26.5 max. 32 max. 1.5 max. Pattern Pattern 5 5±0.5 (17.5) 0.7 0.4 5±0.5 3±1 27.5±0.5 ■Precautions ● Please refer to “Solid State Relays Common Precautions” for correct use. 2 4 1 (17.5) 27.5 5 − 3 + INPUT (−) 21 (+) LOAD Note. The plus and minus symbols shown in the parentheses are for DC loads. G3CN Solid State Relays G 3 C N • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation Electronic and Mechanical Components Company Contact: www.omron.com/ecb Cat. No. K063-E1-06 1014(0207)(O) 3