SynapSense® Wireless Mesh ThermaNode™ S P E C I F I C AT I O N S H E E T specifications The wireless mesh node shall be a battery-operated wireless device designed for environmental node data collection from server and telephony equipment racks and cooling units, as part of a comprehensive cooling optimization solution. Each wireless node shall provide temperature and humidity measurement for up to seven external thermistors connected to the node via a latching connector, allowing for comprehensive capture and consolidation of both front and rear cabinet intake and exhaust readings within each unit. technical information Dimensions: 91.44mm L x 63.5mm W x 30.48mm H (3.6" L x 2.5" W x 1.2"H) Housing: ABS Plastic Packaging: Includes four AA batteries Mounting: Can be mounted using screws (via four holes that accommodate up to #6 machine screws) or with cable ties (via four holes that can accommodate up to 4.572mm or 0.18 in cable tie width) or by double-sided adhesive included. key features and benefits Multi-Faceted Monitoring Unit Replaces the needs for multiple environmental cabinet nodes by consolidating monitoring of various touch points into one single, cost-effective unit Wireless Mesh Network Serves as one node within an innovative wireless mesh network made up of multiple nodes that "talk" to each other to share environmental monitoring data across the data center Simple Deployment Allows wireless placements of nodes at any points, avoiding the cost or time of installing complex or additional connectivity in data center Self-Configuring Self-configures into the existing wireless mesh network structure without needing any complicated configurations by the network administrator Auto Adjusting Receiver Sensitivity Adjusts receiver sensitivity to compensate for powerful ambient radio noise from other devices like Wi-Fi, enabling radios to communicate with each other in harsh RF environments Channel Black-listing Identifies and avoids radio frequencies that have high levels of RF noise, speeding up data transfer and conserving battery life Battery Operated Operates on four AA batteries that provide up to seven years of battery life, cost-effectively powering node over life of data center Time Stamped Data Allows automatic time stamping of each piece of node data to indicate and document the exact time at which data was collected making historical comparisons possible SmartSend Notifications Compares data collected every 30 seconds and recognizes temperature deviations outside of specified thresholds, causing override of configured reporting intervals to ensure that potential concerns are identified for quick resolution Smart-Over-the-Air (SMOTA) Firmware Update Uses wireless network to transmit hardware firmware updates directly to node without need for physical intervention for simplicity of updates* 128-bit Network Encryption Encrypts data over the network using a unique 128-bit key to ensure security Single IP Address Scalability Allows interconnect ability of up to 200 nodes on a single wireless mesh network gateway thru one single IP address, reducing the need for separate IP ports, IP capital costs, and management overhead SmartZone™ Software DCIM Suite integration Captures environmental data that is consolidated by connected gateways and then utilized by SynapSoft® Cooling Software, part of the SmartZone™ Solutions portfolio, for real-time monitoring and display, management, and automated documentation *Performing a firmware upgrade is a specialized process which must involve technical support or a qualified reseller. applications The SynapSense® Wireless Mesh ThermaNode™ is a key component of SynapSense® Cooling Optimization, a turn-key wireless monitoring and cooling control solution for data centers that uses intelligent software, leading edge wireless nodes, and professional services to optimize cooling, increasing current capacity and reducing costs to deliver tangible ROI. The SynapSense® Wireless Mesh ThermaNode™ is a battery-operated wireless device designed for environmental data collection from server and telephony equipment racks and cooling units. Each ThermaNode™ supports up to seven external thermistors connected to the node via a latching connector. Up to 200 sensors can be connected to one single IP address, with expandability up to 2,000 sensors on a w w w. p a n d u it.c o m single network thru additional gateways. This allows an individual ThermaNode™ to be installed on a cabinet to cost-effectively capture front and rear cabinet intake and exhaust readings from connected thermistors at specific points, rather than deploying separate nodes individually. As part of a wireless mesh network, Up to 200 ThermaNodes™ can be connected thru a single IP address to captured real-time temperature and humidity data across a data center. This data is then used by SynapSoft® Cooling Software to create thermal maps and movies to identify developing hotspots or anomalies, find reclaimable cooling capacity, or simply optimize the efficiency of the cooling overall for tangible ROI. Wireless Mesh Nodes ThermaNode™: 99-0501-001 ThermaNode™ EZ (measures temperature): 99-0944-001 ThermaNode™ EZ-H (measures temperature and humidity): 99-0944-010 Pressure Node: 99-0331-001 Constellation Node: 99-0348-003 Wireless Mesh Gateway Gateway: 100-1156-001 Gateway mounting shelf: : 67-0811-003 SynapSoft ® Software Software Fee Modbus Driver: Software Fee BACnet Driver: Software Fee SNMP Driver: Environmental Monitoring License: SWFee-I-MB SWFee-I-BN SWFee-I-SN 99-0794-001 SynapSense® Wireless Mesh ThermaNode™ General Specifications Specifications Node Specifications Description Data Rate Maximum • 2.4 GHz, ISM unlicensed band • IEEE 802.15.4 MAC. • 250 Kbps Maximum RF Output Power • 0 dBm RF Data Range Typical data center environment: 50 feet (15m); Max 260 feet (80m) open air, line of sight Battery Life Five to seven years (typically) Maintenance and Calibration No recalibration or maintenance possible Antenna Type +0 dBi omni-directional antenna Software Requirements Requires SynapSoft® Version X.0 or newer Device Manager Software NOTE: LiveImaging, Device Manager, MapSense, and other software features referenced in this document are included within the SynapSoft® Software Platform. Mechanical Specifications Specifications Connectors Description Molex Micro-Fit^ series 14 position I/O connector for use with external thermistor wire harness (provided) Power Requirements Two or four AA 1.5 VDC lithium batteries Life Expectancy • Temperature Sensors: No recalibration possible. No stated life degradation. We use only US Sensors NTC 10k Jcurve thermistors potted in a vinyl encapsulation. • Internal Humidity Sensors: Manufacturer states 1% per year accuracy degradation. Replace sensors at 10 years (this assume worst case + 12% accuracy for the RH measurements our system provides).. Mechanical Expectancy Protection for electronics is up to seven foot, multi-axis drop (battery compartment may open above two feet) On/Off Switch ThermaNode™ contains an on/off power switch. The switch is ON in the left positon. Regulatory Information • FCC Part 15, Subpart C, 15.247 U62-SRS100 and U62-THERM • Industry Canada 7265A-SRS100 and 7265-THERM • CE Marketing EN 300 328; V1.7.1 (2006-05) and EN 300 440-2 V1.1.2 (2004-07 ^Micro-Fit is a trademark of Molex. ThermaNode™ Internal Sensor (Relative Humidity) Parameter Operating Range 50°F to 95°F (10 TO 35°C) Specification Accuracy Nominal +0.86°F to 0.82°F (+0.48°C to 0.46°C) Accuracy Over Time* • After 1 year +0.92°F to 0.88°F (+0.51°C to 0.49°C) • After 2 years +0.99°F to 0.94°F (+0.55°C to 0.52°C) • After 3 years +1.06°F to 0.99°F (+0.59°C to 0.55°C) T h e r m a N o d e ™ I n t e r n a l S e n s o r ( Te m p e r a t u r e ) Accuracy +0.5°F (+0.3°C) Stability Negligible Operating Range 32°F to 140°F (0°C to 60°C) Time Constant 230 seconds moving air (typical) ThermaNode™ Environmental Specifications Operating 32°F to 140°F (0°C to 60°C) Storage Storage (with batteries) 14°F to 140°F (-10°C to 60°C) SynapSense® Wireless Mesh ThermaNode™ ThermaNode External Sensor Data Parameter Number of Supported Thermistors Temperature Range Specification Up to seven 32°F to 140°F (0°C to 60°C) Temperature Accuracy 10 to 43°C: +0.5°F (+0.3°C) 0 to 10 and 43 to 60°C: +1.2°F (+0.7°C) Time Constant 30 seconds moving air; 60 second static air (typical) Resolution +0.02°F at 77°F (+0.01°C at 25°C) Stability Typically +0.0056°F (0.0031°C) over five years Thermistors 10k ohm, Type J Curve Thermistor Time Constant 60 second static air; 30 second moving air (typical) 1.225 [31.115} 1.160 [29.464] Dimensions 2.550 [64.77] 3.600 [91.44] Regulatory Label Dimensions are in inches. [Dimensions in brackets are metric.] WORLDWIDE SUBSIDIARIES AND SALES OFFICES PANDUIT CANADA Markham, Ontario [email protected] Phone: 800.777.3300 PANDUIT EUROPE LTD. London, UK [email protected] Phone: 44.20.8601.7200 PANDUIT SINGAPORE PTE. LTD. Republic of Singapore [email protected] Phone: 65.6305.7575 PANDUIT JAPAN Tokyo, Japan [email protected] Phone: 81.3.6863.6000 PANDUIT LATIN AMERICA Guadalajara, Mexico [email protected] Phone: 52.33.3777.6000 PANDUIT AUSTRALIA PTY. LTD. Victoria, Australia [email protected] Phone: 61.3.9794.9020 For a copy of Panduit product warranties, log on to www.panduit.com/warranty For more information Visit us at www.panduit.com Contact Customer Service by email: [email protected] or by phone: 800.777.3300 © 2015 Panduit Corp. ALL RIGHTS RESERVED. PVSP127--WW-ENG 6/2015