CONNOR-WINFIELD MSTM-S3-R

C O N N O R THE CONNOR-WINFIELD CORP.
2111 COMPREHENSIVE DRIVE.
IL 60505.
W I N F I E L D AURORA,
FAX (630) 851-5040.
NETWORK ELEMENT TIMING GENERATOR
PHONE (630) 851-4722
HTTP://WWW.CONWIN.COM
DESCRIPTION
STRATUM 3 SIMPLIFIED CONTROL
TIMING MODULES (MSTM-S3-R)
Fig. 1
The Connor-Winfield Stratum 3 Simplified Control
Timing Module acts as a complete system clock module for general
Stratum 3 timing applications. The MSTM is designed for external
control functions. Full external control input allows for selection
and monitoring of any of four possible operating states: 1)
Holdover, 2) External Reference #1, 3) External Reference #2,
and 4) Free Run. The table below illustrates the control signal
inputs and corresponding operational states:
MSTM-S3-R PIN ASSIGNMENT
+5Vdc
18
1
HOLDOVER
EX REF 1
17
2
REF 1
GND
16
3
REF 2
EX FEF 2
15
4
FREERUN
14
5
GND
CLK_OUT
13
6
ALARM OUT
GND
12
7
CNTL A
SYNC_OUT
11
8
CNTL B
TRI-STATE
10
9
PLL TVL
GND
In the absence of External Control Inputs (A,B), the
MSTM enters the Free Run mode and signals an External Alarm.
The MSTM will enter other operating modes upon application of
a proper control signal. Mode 1 operation (A=1, B=0) results in
an output signal that is phase locked to the External Reference
Input #1. Mode 2 operation (A=0, B=1) results in an output signal
that is phase locked to External Reference Input #2. Holdover
mode operation (A=1, B=1) results in an output signal at or near
the frequency as determined by the latest (last) locked-signal input
values and the holdover performance of the MSTM. In Free Run
mode, operation (A=0, B=0) is a guaranteed output of 4.6 ppm of
the nominal frequency.
BOTTOM VIEW
Fig. 2
BLOCK DIAGRAM
0
CNTL A
Alarm signals are generated at the Alarm Output during
Holdover and Free Run operation. Alarm Signals are also
generated by loss-of-lock, loss of Reference, and by a Tune-Limit
indication from the PLL. A Tune-Limit alarm signal indicates
that the VCXO tuning voltage is approaching within 10% the limits
of its lock capability and that the External Reference Input may
be erroneous. A high level indicates an alarm condition. Realtime indication of the operational mode is available at unique
operating mode outputs on pins 1-4.
CNTL B
2:4
EX REF 1
EX REF 2
FREE RUN
1
REF 1
2
REF 2
3
PLL TVL
FREE RUN
HOLD OVER
ALARM OUT
LOCK AND
DETECTION
PHASE
COMPARATOR
2:1
MUX
HOLD OVER
2:1
MUX
DAC
FILTERS
DAC
STRATUM3
TCXO
TUNING
VOLTAGE
MONITOR
FIFO
STRATUM3
TCXO
SYNC_OUT
CLK_OUT
PLL_TVL
Control loop filters effectively attenuate any reference
jitter and smooth out phase transients.
MSTM-S3-R
TABLE 1.0
CONTROL
INPUTS
TRI-STATE
0
OPERATIONAL MODE
A
B
0
0
REF 1
REF2
0
0
NORMAL
PLL TUNING VOLTAGE LIMIT
LOR + LOL
1
1
1
0
0
0
0
0
0
0
0
0
0
1
0
0
1
1
NORMAL
PLL TUNING VOLTAGE LIMIT
LOR + LOL
0
0
0
1
1
1
0
0
0
0
0
0
0
1
0
0
1
1
0
0
1
0
0 or 1
1
FREE RUN MODE (DEFAULT)
EXTERNAL
REFERENCE
#1
MODE
EXTERNAL
REFERENCE
#2
MODE
0
1
0
0
0
1
0
1
1
HOLD OVER MODE
1
X
X
TRI-STATE MODE
HIGH IMPEDANCE
Specifications subject to change without notice.
PRELIMINARY
DATA SHEET #: TM022
____________
INDICATOR PIN
OUTPUTS
HOLD
ALARM
FREE RUN PLL_TVL
OVER
OUTPUT
0
1
0
1
PAGE______
1
OF _______
7
REV:________
P02
DATE:____________
3/21/01
C O N N O R THE CONNOR-WINFIELD CORP.
2111 COMPREHENSIVE DRIVE.
IL 60505.
W I N F I E L D AURORA,
FAX (630) 851-5040.
NETWORK ELEMENT TIMING GENERATOR
STRATUM 3 SIMPLIFIED CONTROL
TIMING MODULES (MSTM-S3-R)
PHONE (630) 851-4722
HTTP://WWW.CONWIN.COM
TABLES OF CONTENTS
TABLE 2.0
ABSOLUTE MAXIMUM RATING
SYMBOL
PARAMETER
MINIMUM
V CC
Pow er Supply Voltage (V CC to GND)
V IN
TST G
MAXIMUM
UNITS
NOTES
-0.5
+7
Volts
1.0
Input voltage w ith respect to ground
-0.5
V CC + 0.5
Volts
1.0
Storage temperature
-65°
+150°
°C
1.0
M AXIM UM
UNITS
NOTES
4 .5
V
2 .0
5 .2 5
V
2 .0
VC C
V
0 .0
0 .8
V
TABLE 3.0
INPUT AND OUTPUT CHARACTERISTICS
SYM BOL
PARAM ETER
VTH
R e s e t th re s h o ld vo lta g e
4 .2 5
VC C
Su p p ly Vo lta g e
H ig h le ve l in p u t vo lta g e (TTL
C o m p a tib le )
L o w le ve l in p u t vo lta g e (TTL
C o m p a tib le )
H ig h le ve l o u tp u t vo lta g e
@ IOH = -8 .0 m A, VC C m in im u m
L o w le ve l o u tp u t vo lta g e
@ IOH = 8 .0 m A, VC C m a xim u m
4 .7 5
VIH
VIL
VOH
VOL
M INIM UM
tIN
Tra n s itio n tim e o f in p u t s ig n a l
C IN
In p u t ca p a cita n ce
C OU T
Ou tp u t ca p a cita n ce
Tra n s itio n tim e o f clo ck o u tp u t fro m
h ig h to lo w w ith n o lo a d
Tra n s itio n tim e o f clo ck o u tp u t fro m
lo w to h ig h w ith n o lo a d
8 kH z in p u t re fe re n ce s ig n a l’s
p o s itive p u ls e w id th
8 kH z in p u t re fe re n ce s ig n a l’s
n e g a tive p u ls e w id th
tH L
tLH
tR IP
tR IN
NOMINAL
TABLE 4.0
NOM INAL
5 .0
2 .4
V
0 .4
V
2 5 0 .0
nS
1 5 .0
pF
5 0 .0
pF
4 .0
nS
4 .0
nS
2 5 .0
nS
2 5 .0
nS
SPECIFICATIONS
PARAMETER
NOTES
Frequency Range
19.44 MHz
Supply Current
120 mA
Timing Reference Inputs
8 kHz
Jitter and Phase Tolerance
3.0
Ref-GR-1244-CORE 4.2 - 4.4
Wander Generation
Ref-GR-1244-CORE 5.3
Free Run Accuracy
±4.6 ppm
Hold Over Stabilty
±0.37
Initial Offset
0.05
Temperature
0.28
Drift
0.04
Hold Over History
30 sec.
±4.6 ppm Minimum
Pull-in / Hold-in Range
Lock Time
5.0
< 100 sec.
Correction Period
125 uS
TVL Alarm
1 = WARNING : Refernce is nearing operational limit
6.0
Specifications subject to change without notice.
PRELIMINARY
DATA SHEET #: TM022
____________
4.0
PAGE______
2
OF _______
7
REV:________
P02
DATE:____________
3/21/01
C O N N O R THE CONNOR-WINFIELD CORP.
2111 COMPREHENSIVE DRIVE.
IL 60505.
W I N F I E L D AURORA,
FAX (630) 851-5040.
NETWORK ELEMENT TIMING GENERATOR
PHONE (630) 851-4722
HTTP://WWW.CONWIN.COM
STRATUM 3 SIMPLIFIED CONTROL
TIMING MODULES (MSTM-S3-R)
PIN DESCRIPTION
MSTM-S3
PIN #
1
HOLD OVER
-Output. High when the control inputs select Holdover.
2
REF 1
-Output. High when the control inputs select EX REF 1.
3
REF 2
-Output. High when the control inputs select EX REF 2.
4
FREE RUN
-Output. High when the control input selects Free Run.
5
Gnd
-Ground.
6
ALARM_OUT
-Ouput. =1,If (FREE RUN + HOLD OVER + LOR + LOL + PLL_TVL) .
7
CNTL A
-Mode control input.
8
CNTL B
-Mode control input.
9
PLL_TVL
-Tuning Voltage Alarm. =1 If CAPTURE RANGE NEAR 10% OF EXTREME (~11ppm).
10
TRI-STATE
-Tri-state enable = 1. All outputs ae put into a high impedance state.
11
SYNC_OUT
-Syncronized output.
12
Gnd
-Ground.
13
CLK_OUT
-Stratum 3 TCXO output. (Non-synchronized).
14
Gnd
-Ground.
15
EX REF 2
-External Reference #2 Input. (8 KHz)
16
Gnd
-Ground.
17
EX REF 1
-Input. External Reference #1 Input. (8 KHz)
18
+5 Vdc
+5 Volt DC supply.
NOTES FOR TABLES 1.0 - 4.0
NOTES:
1.0
Operation of the device at these or any other conditions beyond those listed under Recommended Operating Conditions is not implied. Exposure to
Absolute Maximum Ratings conditions for extended periods of time may affect device reliability.
2.0
Power-on Reset will activate within the stated range
3.0
Ref- GR1244-CORE 3.2.1 R3-1.
4.0
Holdover stability is the cumulative fractional frequency offset containing Initial Offset, Temperature, and Drift components as described by
Bellcore GR-1244-CORE 5.2.
5.0
Pull-in range is the minimum frequency deviation on the reference inputs to the timing module that can be overcome to pull itself into synchronization
with the reference.
6.0
A ‘1’ level indicates unit is within the extreme 10% of its operating range tracking the reference (~11ppm). Consult factory for use as a reference
quilifier.
Specifications subject to change without notice.
PRELIMINARY
DATA SHEET #: TM022
____________
PAGE______
3
OF _______
7
REV:________
P02
DATE:____________
3/21/01
C O N N O R THE CONNOR-WINFIELD CORP.
2111 COMPREHENSIVE DRIVE.
IL 60505.
W I N F I E L D AURORA,
FAX (630) 851-5040.
PHONE (630) 851-4722
HTTP://WWW.CONWIN.COM
NETWORK ELEMENT TIMING GENERATOR
STRATUM 3 SIMPLIFIED CONTROL
TIMING MODULES (MSTM-S3-R)
Fig. 3
1 µ s Transient Response
1200
1000
TIE (ns)
800
600
400
200
0
-200
0
1
2
3
4
5
6
7
8
9
10
Time (sec)
Fig. 4
P h a s e T ra n s ie n t M T IE fo r M S T M -S 3 -R
1 00 00
MTIE (ns)
10 00
G R-253, F ig . 5-19
M T IE (n s)
1 00
10
1
0 .01
0 .1
1
10
10 0
1 00 0
O b s erv atio n T im e (se c )
Specifications subject to change without notice.
PRELIMINARY
DATA SHEET #: TM022
____________
PAGE______
4
OF _______
7
REV:________
P02
DATE:____________
3/21/01
C O N N O R THE CONNOR-WINFIELD CORP.
2111 COMPREHENSIVE DRIVE.
IL 60505.
W I N F I E L D AURORA,
FAX (630) 851-5040.
PHONE (630) 851-4722
HTTP://WWW.CONWIN.COM
NETWORK ELEMENT TIMING GENERATOR
STRATUM 3 SIMPLIFIED CONTROL
TIMING MODULES (MSTM-S3-R)
Fig. 5
S a m p le W a n d e r G e n e ra tio n (T D E V) fo r M S T M -S 3 -R
100
T D EV (n s)
G R 1 24 4 , F i g 5. 1
TDEV (ns)
10
1
10000
1000
100
10
1
0.1
0 .1
In te g ra tio n T im e (s e c .)
Fig. 6
S a m p le C a lib ra te d W a n d e r T ra n s fe r (T D E V)
fo r M S T M -S 3 -R
1 00 0 0
TDEV (ns)
10 0 0
100
T D EV (n s)
G R 1244, F ig 5.3
10
10000
1000
100
10
1
0.1
0.01
1
In te g ra tio n T im e (S e c .)
Specifications subject to change without notice.
PRELIMINARY
DATA SHEET #: TM022
____________
PAGE______
5
OF _______
7
REV:________
P02
DATE:____________
3/21/01
C O N N O R THE CONNOR-WINFIELD CORP.
2111 COMPREHENSIVE DRIVE.
IL 60505.
W I N F I E L D AURORA,
FAX (630) 851-5040.
PHONE (630) 851-4722
HTTP://WWW.CONWIN.COM
NETWORK ELEMENT TIMING GENERATOR
STRATUM 3 SIMPLIFIED CONTROL
TIMING MODULES (MSTM-S3-R)
Fig. 6
S a m p le W a n d e r G e n e ra tio n (M T IE ) fo r M S T M -S 3 -R
1000
G R 1 2 4 4, F ig 5. 2 (A )
G R 1 2 4 4, F ig 5. 2 (B )
MTIE (ns)
G R 2 5 3 -5 . 4 .4 . 3 .2 , F i g 5. 1 7
M T I E (n s)
100
1000000
100000
10000
1000
100
10
1
0.1
0.01
10
O b s e rv a tio n T im e (s e c .)
Fig. 7
Power on reset for MSTM-S3-R
VCC
VTH
Range
Reset
Normal Operation
Specifications subject to change without notice.
PRELIMINARY
DATA SHEET #: TM022
____________
Reset
PAGE______
6
OF _______
7
REV:________
P02
DATE:____________
3/21/01
C O N N O R THE CONNOR-WINFIELD CORP.
2111 COMPREHENSIVE DRIVE.
IL 60505.
W I N F I E L D AURORA,
FAX (630) 851-5040.
PHONE (630) 851-4722
HTTP://WWW.CONWIN.COM
Fig. 8
NETWORK ELEMENT TIMING GENERATOR
STRATUM 3 SIMPLIFIED CONTROL
TIMING MODULES (MSTM-S3-R)
Fig. 9
APPLICATIONS CIRCUIT DIAGRAM
BLOCK DIAGRAM
MSTM-S3
PACKAGE
WITH COVER
5 VOLT DC
POWER
SUPPLY
.030
(.762mm)
.078
.180
(4.572mm)
.040
(1.98mm)
.150
+5Vdc
(3.81mm)
(1.02mm)
NETWORK
TIMING
REFERENCE
INPUT
eg. BITS CLOCK,etc.
DETAIL "A-A"
"A-A"
2.000
.200 TYP (4)
(50.08mm)
(5.08mm) TYP
1.600
(40.64mm)
2.000
(50.08mm)
18
1
17
2
16
3
15
4
14
5
13
.200 TYP
7
11
(16)
8
10
(5.08mm) TYP
9
GND
.555
(14.1mm)
FREE RUN CLOCK
COPY
PIN 1
REF 1
SYSTEM
CONTROL
AND DATA
INPUTS
FREE RUN
GND
CLK_OUT
GND
SYSTEM
CLOCK
HOLD OVER
REF 2
EX REF 2
GND
.200 TYP
(5.08mm) TYP
6
12
EX REF 1
ALARM OUT
CNTL A
SYNC_OUT
CNTL B
TRI-STATE
PLL TVL
LOSS OF
REFERENCE
MONITOR
SECTION
BOTTOM VIEW
REVISION
REVISION DATE
NOTE
P00
3/6/01
Preliminary Release
P01
3/9/01
Added Reset graph
P02
3/21/01
Added min/max Vcc
Specifications subject to change without notice.
PRELIMINARY
DATA SHEET #: TM022
____________
PAGE______
7
OF _______
7
REV:________
P02
DATE:____________
3/21/01