Quick Guide to CFI AN

AN98488
Quick Guide to Common Flash Interface
Common Flash Interface (CFI) is a standard introduced by the Joint Electron Device Engineering Council (JEDEC) to allow insystem or programmer reading of flash device characteristics. Refer to the JEDEC CFI publications JEP137B and JESD68.01.
Contents
1
Introduction .................................................................. 1
2
Common Flash Interface.............................................. 1
2.1 Cypress CFI Implementation ............................... 2
3
CFI Tables ................................................................... 2
3.1 CFI Query Identification String ............................ 2
3.2 System Interface String ....................................... 3
1
3.3
3.4
3.5
Device Geometry Definition .................................4
Primary Vendor-Specific Extended Query ...........7
Alternate Vendor-Specific Extended Query .......12
4 Conclusion.................................................................. 12
Document History Page ...................................................13
Worldwide Sales and Design Support ..............................14
Introduction
Common Flash Interface (CFI) is a standard introduced by the Joint Electron Device Engineering Council
(JEDEC) to allow in-system or programmer reading of flash device characteristics, which is equivalent to having
data sheet parameters located in the device. The JEDEC Solid State Technology Association defines industry
standards for semiconductor devices, with CFI being one of the many. The CFI is used to standardize flash device
characteristics and to define feature differences between various flash manufacturers. For a detailed definition of
CFI, see the JEDEC CFI publications JEP137 and JESD68.
2
Common Flash Interface
CFI is a way of defining the flash device characteristics in silicon. It is implemented in a set of tables that define
the various characteristics of the flash device, which application software can interrogate. CFI tables are divided
into the following five separate parts:

CFI Query Identification String

System Interface String

Device Geometry Definition

Primary Vendor-Specific Extended Query

Alternate Vendor-Specific Extended Query
The CFI Query Identification String, System Interface String, and Device Geometry Definition table descriptions
are identical for all flash manufacturers. The Primary Vendor-Specific Extended Query and Alternate VendorSpecific Extended Query table sections allow flash manufacturers to indicate unique features.
CFI addressing depends on the device and its mode of operation. For devices that are x8-only, x16-only, x32-only,
x8/x16-capable, but operating in the x16-mode, or x16/x32-capable but operating in the x32 mode, byte
addressing starts at 10h and is incremented by a factor of one. For x8/x16-capable devices operating in the x8mode or x16/x32-capable device operating in the x16-mode, word addressing starts at 20h and is incremented by
a factor of two. For x8/x32-capable devices operating in the x8-mode, double-word addressing starts at 40h and is
incremented by a factor of four.
CFI addressing in the following examples are shown with the maximum data bus width, which means x32 or x16/
x32 capable device in x32-mode, x16 or x8/x16 capable device in x16-mode, and x8 device in x8-mode. CFI
codes are taken from various flash devices; these do not represent individual devices.
www.cypress.com
Document No. 001-98488 Rev. *C
1
Quick Guide to Common Flash Interface
2.1
Cypress CFI Implementation
Not all Cypress flash devices implement all the five CFI parts.
For parallel NOR flash, Alternate Vendor- Specific Extended Query is not implemented, while all the other four
parts are implemented.
For SPI flash, FL-K and FL-P do not have CFI tables implemented. FL-S and FS-S implement all the five CFI
parts, including Primary Vendor-Specific Extended Query, and Alternate Vendor- Specific Extended Query table
sections.
3
3.1
CFI Tables
CFI Query Identification String
The CFI Query Identification String table starts from the flash device physical address 10h and ends at 1Ah.
Addresses 10h to 12h define the ASCII string “QRY” that is used in Query Structure Output to indicate the flash
device bus width and its bus mode.
Table 1. Query Structure Output
Address
Data (x8)
Data (x16)
Definition
10h
51h
0051h
'Q' in ASCII
11h
52h
0052h
'R' in ASCII
12h
59h
0059h
'Y' in ASCII
Addresses 13h and 14h define the flash manufacturer identification number, or the Primary Vendor Command Set
and Control Interface ID Code. The Cypress Manufacturer ID for flash devices is 0002h (historically the AMD ID is
0002h and the Fujitsu ID is 0004h; the former Spansion ID is 0002h).
In the CFI tables, lower and upper bytes are assigned to consecutive addresses whenever a definition can have a
16-bit data value. For example, the Manufacturer ID value is 0002h. For the x8 case, the lower data byte is 02h at
Address 13h and the upper data byte is 00h at Address 14h. For the x16 case, the data values are the same, but
00h is added as the high byte to each data value.
Table 2. Primary Vendor Command Set and Control Interface ID Code
Address
Data (x8)
Data (x16)
Definition
13h
02h
0002h
Manufacturer ID
Lower Byte
14h
00h
0000h
Manufacturer ID
Upper Byte
Addresses 15h and 16h define the starting address of the Primary Vendor-Specific Extended Query table. The
starting address for the Primary Vendor-Specific Extended Query table starts at address 40h for Cypress
products, whereas it may start at address 31h for other manufacturers.
Table 3. Primary Vendor-Specific Extended Query
Address
Data (x8)
Data (x16)
Definition
15h
40h
0040h
Starting Address for the Primary Vendor-Specific Extended
Query table Lower Byte
16h
00h
0000h
Starting Address for the Primary Vendor-Specific Extended
Query table Upper Byte
Addresses 17h and 18h define the alternate flash manufacturer identification number or the Alternate Vendor
Command Set and Control Interface ID Code. Cypress NOR devices do not implement this feature, so the data is
www.cypress.com
Document No. 001-98488 Rev. *C
2
Quick Guide to Common Flash Interface
00h 00h (none exists). Cypress SPI FL-S and FS-S devices have this feature implemented; the data is 46h 53h,
which is ASCII characters “FS”. “F” is for SPI interface; “S” represents the 65-nm Technology Node.
Table 4. Alternate Vendor Command Set and Control Interface ID Code
Address
Data
Definition
17h
00h/53h
Alternate Manufacturer ID
Lower Byte
18h
00h/46h
Alternate Manufacturer ID
Upper Byte
Addresses 19h and 1Ah define the starting address of the Alternate Vendor-Specific Extended Query table.
Cypress NOR devices do not implement this feature; the data is 00h 00h (none exists). The starting address for
the Alternate Vendor-Specific Extended Query table for Cypress SPI FL-S and FS-S starts at Address 51h.
Table 5. Alternate Vendor-Specific Extended Query
3.2
Address
Data
Definition
19h
00h/51h
Starting Address for Alternate Vendor-Specific Extended Query table
Lower Byte
1Ah
00h
Starting Address for Alternate Vendor-Specific Extended Query table
Upper Byte
System Interface String
The System Interface String table starts from the flash device physical address 1Bh and ends at 26h.
Addresses 1Bh and 1Ch define the minimum and maximum limits of the Power Supply Voltage (VCC). Note that
when rounding the VCC, the lower limit (address 1Bh) should always be rounded up and the higher limit (address
1Ch) should always be rounded down.
Table 6. Power Supply Voltage
Address
Data
Definition
1Bh
27h
27 / 10 = 2.7 V
VCC lower limit (D7-D4: V, D3-D0: 100 mV)
1Ch
36h
36 / 10 = 3.6 volts
VCC upper limit (D7-D4: V, D3-D0: 100 mV)
Addresses 1Dh and 1Eh define the minimum and maximum limits of the Dual Supply Programming Voltage (VPP).
This is only available on legacy devices since newer devices have migrated to single-supply programming.
Table 7. Dual Supply Programming Voltage
Address
Data
Definition
1Dh
00h
VPP lower limit (00h = no VPP pin present)
1Eh
00h
VPP upper limit (00h = no VPP pin present)
Addresses 1Fh and 23h define the typical and maximum timeout values of single byte/word programming in
microseconds. Typical time = 2N µs and maximum time = 2N times typical.
Table 8. Single Byte/Word Programming
Address
www.cypress.com
Data
Definition
1Fh
07h
27 = 128 µs
Typical word programming time from Erase and Programming Performance
table in the datasheet
23h
01h
21 = 2 -> 2*128 µs = 256 µs
Maximum word programming time, which is the maximum programming time
expected before a timeout is generated
Document No. 001-98488 Rev. *C
3
Quick Guide to Common Flash Interface
Addresses 20h and 24h define the typical and maximum timeout values of the entire buffer programming in
microseconds. Typical time = 2N µs and maximum time = 2N times typical. For SPI, it is for Page Program.
Table 9. Buffer Programming Timeout Values
Address
Data
Definition
7
20h
07h
2 = 128 µs
typical buffer programming time
24h
05h
25 = 32 -> 32*128 µs = 4096 µs
maximum buffer programming time
Addresses 21h and 25h define the typical and maximum timeout values of the sector erase operation in
milliseconds. Typical time = 2N ms and maximum time = 2N times typical.
Sector and block are equivalent names for the smallest erasable size in Cypress flash memories. The boot sector
flash memory contains multiple sector sizes, but the Address 21h definition corresponds to the time taken to erase
the largest sector size of the device.
Table 10. Sector Erase Timeout Values
Address
Data
Definition
21h
0Ah
210 = 1024 ms
Typical sector erase time
25h
04h
24 = 16 -> 16*1024 ms = 16,384 ms
Maximum sector erase time
Addresses 22h and 26h define the typical and maximum timeout values of the chip erase operation in
milliseconds. Typical time = 2N ms and maximum time = 2N times typical.
Table 11. Chip Erase Timeout Values
Address
3.3
Data
Definition
N
22h
4Fh
2 ms
Typical chip erase time
26h
04h
2N = N * typical chip erase time
Maximum chip erase time (00h = not supported)
Device Geometry Definition
The Device Geometry Definition table starts from the flash device physical address 27h and ends at 3Ch.
Address 27h defines the device density in bytes.
Table 12. Device Density
Address
27h
Data
17h
Definition
17h = 23 -> 2
23
= 8 MB
Addresses 28h and 29h define the flash device data bus interface. It defines parallel NOR and SPI flash
interfaces. For parallel NOR, these values are as follows:
00h = x8-only interface
01h = x16-only interface
02h = x8/x16 interface
03h = x32 interface
www.cypress.com
Document No. 001-98488 Rev. *C
4
Quick Guide to Common Flash Interface
Table 13. Data Bus Interface — Parallel NOR
Address
Data
Definition
28h
02h
x8/x16 interface
Lower byte
29h
00h
x8/x16 interface
Upper byte
For SPI serial Flash devices:
04h = Single I/O SPI, 3-byte address
05h = Multi I/O SPI, 3-byte address
0102h = Multi I/O SPI, 3- or 4-byte address
Table 14. Data Bus Interface — SPI Flash
Address
Data
Definition
28h
04h
SPI flash interface
Lower byte
29h
00h
SPI flash interface
Upper byte
Addresses 2Ah and 2Bh define the maximum number of bytes in a multi-byte write operation, which is equal to 2N.
00h is indicated if the multi-byte write feature not supported.
Table 15. Maximum Number of Bytes
Address
Data
Definition
5
2Ah
05h
2 = 32 bytes / Buffer length
Lower byte
2Bh
00h
Buffer length
Upper byte
Addresses 2Ch through 3Ch define the Erase Block regions of the flash device. The information stored at these
address locations indicate how the flash memory map is organized.
Address 2Ch defines the number of Erase Block regions within the flash device.
Table 16. Number of Erase Block Regions
Address
Data
2Ch
01h
Definition
Number of Erase Block regions
Figure 1 shows some examples of defining the number of erase block regions within a Cypress flash device.
Figure 1. Examples of Erase Block Regions
Uniform
Sectors
Boot Sectors
Boot Sectors
Uniform
Sectors
Uniform
Sectors
Boot Sectors
www.cypress.com
Document No. 001-98488 Rev. *C
5
Quick Guide to Common Flash Interface
Each erase block region refers to a group of sectors that have the same sector size. For example, a flash device
with Uniform Sectors has sectors of the same size across the entire flash array; the number of erase block regions
for this flash device is 01h.
A top or bottom boot flash device has uniform, smaller-size boot sectors at the top or the bottom. The rest of the
flash array is of uniform larger-size sectors; thus, there are two Erase Block regions and the number of erase
block regions is 02h.
A top and bottom boot flash device has uniform smaller-size boot sectors at both top bottom. The rest of the flash
array has larger-sized uniform sectors; thus, there are three Erase Block regions and the number of erase block
regions is 03h.
Addresses 2Dh through 30h, 31h through 34h, 35h through 38h, and 39h through 3Ch define the information of
Erase Block Regions 1, 2, 3, and 4, respectively. These include the following:
1.
The number of sectors
2.
The sector size inside each Erase Block region.
The lower two addresses specify the number of sectors. The number of sectors equals the CFI data plus 1. For
example, if the data in the CFI table is 07h, then the number of sectors in the Erase Block region is 8.
The upper two addresses specify the sector size. The sector size equals the CFI data multiplied by 256 bytes. For
example, if the data in the CFI table is 20h, then the sector size is 20h x 256 (decimal) bytes, which is 8 KB.
Table 17 is an example of a top-and-bottom boot flash. At both ends of the memory map, there are eight 8-KB
boot sectors. Besides the boot sectors located at the two ends of the memory map, there are 64-KB uniform
sectors between the top and bottom boot sectors. Boot sectors at each end of the memory map can be classified
as individual regions, while all uniform sections are another region. Thus, there are three regions, which include
the first eight boot sectors, the middle uniform sectors, and then the second eight boot sectors. Each of the three
regions is defined as below:
Table 17. Region 1
Address
Data
Definition
2Dh
07h
07h = 07h + 01h = 8 sectors
Lower byte
2Eh
00h
number of sectors
Upper byte
2Fh
20h
20h = 32 * 256 bytes = 8-KB sector size
Lower byte
30h
00h
Sector size
Upper byte
Table 18. Region 2
Address
Data
Definition
31h
FDh
FDh = FDh + 01h = FEh = 254 sectors
Lower byte
32h
00h
number of sectors
Upper byte
33h
00h
100h = 256 * 256 bytes = 64-KB sector size
Lower byte
34h
01h
sector size
Upper byte
Table 19. Region 3 (Sheet 1 of 2)
www.cypress.com
Address
Data
Definition
35h
07h
07h = 07h + 01h = 8 sectors
Lower byte
36h
00h
Number of sectors
Upper byte
Document No. 001-98488 Rev. *C
6
Quick Guide to Common Flash Interface
Table 19. Region 3 (Sheet 2 of 2)
Address
Data
Definition
37h
20h
20h = 32 * 256 bytes = 8KB sector size
Lower byte
38h
00h
Sector size
Upper byte
The unused erase block regions, address 39h through 3Ch, are left empty at 00h.
3.4
Primary Vendor-Specific Extended Query
Addresses 40h to 42h define the ASCII string “PRI”. The string PRI indicates the beginning of the Primary VendorSpecific Extended Query table.
Table 20. Primary Vendor-Specific Extended Query
Address
Data
Definition
40h
50h
'P' in ASCII
41h
52h
'R' in ASCII
42h
49h
'I' in ASCII
Address 43h and 44h defines the Major and Minor version number of the Cypress CFI version implemented.
Table 21. Cypress CFI Version
Address
Data
Definition
43h
31h
Version 1.4 major version number
'1' in ASCII
44h
34h
Version 1.4 minor version number
'4' in ASCII
Address 45h specifies whether the flash device has the Address-Sensitive Unlock functionality and indicates the
Process Technology of the flash device.
The Address-Sensitive Unlock functionality shows that the addresses during command cycles are don't cares.
DQ7-DQ6 are reserved
DQ5-DQ2 defines the Process Technology
DQ1-DQ0 defines the Address-Sensitive Unlock; 0 = Supported, 1 = Not Supported
Table 22. Address-Sensitive Unlock and Process Technology
Address
Data
45h
08h
Definition
08h = 00001000b
DQ1-DQ0 -> 00b -> Address-Sensitive Unlock supported
DQ5-DQ2 -> 0000b -> 230-nm Floating Gate technology
0001b -> 170-nm Floating Gate technology
0010b -> 230-nm MirrorBit technology
0011b -> 130-nm Floating Gate technology
0100b -> 110-nm MirrorBit technology
0101b -> 90-nm MirrorBit technology
0110b -> 90-nm Floating Gate technology
0111b -> 65-nm MirrorBit Eclipse technology
1000b -> 65-nm MirrorBit technology
1001b -> 45-nm MirrorBit technology
DQ7-DQ6 -> 00b -> Reserved
www.cypress.com
Document No. 001-98488 Rev. *C
7
Quick Guide to Common Flash Interface
Address 46h defines rase Suspend and indicates 00h if Erase Suspend is not supported; 01h if support is for
Read Only; or 02h if support is for both Read and Write.
Table 23. Erase Suspend
Address
Data
Definition
46h
02h
Erase Suspend supports both Read and Write operations
Address 47h defines the number of sectors in the smallest Sector Group protected in the flash device.
Table 24. Sector Group
Address
Data
47h
01h
Definition
Sector Protect
00 = Not supported
X = Number of sectors in smallest group
Address 48h defines the Temporary Sector Unprotect functionality. Temporary Sector Unprotect is a functionality
that unlocks protected sectors by applying a high-voltage VID to the RESET# pin.
Table 25. Temporary Sector Unprotect
Address
48h
Data
01h
Definition
Temporary Sector Unprotect
00 = Not supported
01 = Supported
Address 49h defines the Sector Protection Scheme.
Table 26. Sector Protection Scheme
Address
Data
49h
04h
Definition
Sector Protect/Unprotect Scheme
Table 27 provides different data code and definition mode options for Address 49h, as shown in Table 26.
Table 27. Address 49h Data and Definition Table
Data Code
Definition Mode
04h
High-Voltage Method
05h
Software Command-Locking Method
08h
Advanced Sector-Protection Method
09h
Secure
Address 4Ah specifies whether simultaneous operations are supported and the number of banks in the flash
device.
Table 28. Number of Sectors Outside Bank 1
Address
Data
4Ah
00h
Definition
Simultaneous operation
00 = Not supported
X = Number of banks
Address 4Bh defines if the flash device supports burst mode.
Table 29. Burst Mode
www.cypress.com
Address
Data
4Bh
00h
Definition
Burst Mode
00 = Not supported
01 = Supported
Document No. 001-98488 Rev. *C
8
Quick Guide to Common Flash Interface
Address 4Ch specifies whether the flash device supports page mode and page size.
Table 30. Page Mode
Address
Data
4Ch
Definition
00h
Not supported
01h
4-word page supported
02h
8-word page supported
03h
16-word page supported (for NOR) 256-byte program page (for
SPI)
04h
512-byte program page (for SPI)
Addresses 4Dh and 4Eh define the minimum and maximum limits of the Acceleration Power Supply Voltage
(A CC ). Bits 7-4 represent the volts in hex, while bits 3-0 represent the BCD equivalent value in 100-mV
increments. Data 00h means that this feature is not supported.
Table 31. Acceleration Power Supply Voltage
Address
Data
Definition
4Dh
B5h
11.5 V (Bits 7-4: 1011 and Bits 3-0: 0101)
ACC lower limit
4Eh
C5h
12.5 V (Bits 7-4: 1100 and Bits 3-0: 0101)
ACC higher limit
Address 4Fh specifies whether the flash device consists of uniform sectors, uniform sectors mixed with boot
sectors, and the write protect function from the WP# pin.
00 = Flash device without WP Protect
01 = Eight 8-KB sectors at TOP and Bottom with WP Protect (for NOR)
= Whole Chip (for SPI)
02 = Bottom Boot Device with WP Protect
03 = Top Boot Device with WP Protect
04 = Uniform, Bottom WP Protect
05 = Uniform, Top WP protect
06 = WP protect for all sectors
07 = Uniform, Top or Bottom WP protect (user selected)
Table 32. Sector and WP# Pin Protection Scheme
Address
Data
4Fh
02h
Definition
Bottom Boot with WP#
Address 50h defines Program Suspend. For SPI, 50h is the last CFI Primary Vendor-Specific Extended Query
data. Starts from 51h, is CFI Alternate Vendor-Specific Extended Query data.
Table 33. Program Suspend
Address
50h
www.cypress.com
Data
01h
Definition
Program suspend
00 = Not supported
01 = Supported
Document No. 001-98488 Rev. *C
9
Quick Guide to Common Flash Interface
Address 57h defines Bank Organization. If data at Address 4Ah is 00h, indicating that Simultaneous Operation is
not supported, Address 57h will also indicates 00h.
Table 34. Bank Organization
Address
Data
57h
04h
Definition
04h = 04 = Number of Banks
Addresses 58h to 5Bh define the “Bank Region Information” – the number of sectors in bank for Banks 1, 2, 3, and
4 respectively.
Table 35. Bank Region Information
Address
3.4.1
Data
Definition
58h
27h
Bank A Region Information:
27h = 39 = Number of sectors in Bank 1
59h
60h
Bank B Region Information:
60h = 96 = Number of sectors in Bank 2
5Ah
60h
Bank C Region Information:
60h = 96 = Number of sectors in Bank 3
5Bh
27h
Bank D Region Information:
27h = 39 = Number of sectors in Bank 4
Primary Vendor-Specific Extended Query Changes in Version 1.4 and Newer
Cypress 65-nm and newer parallel NOR devices implement Version 1.4 and newer Primary Vendor-Specific
Extended Query. There are some new parameters added that are not defined in version 1.3 and earlier versions.
Address 51h defines the Unlock Bypass feature.
Table 36. Unlock Bypass
Address
51h
Data
01h
Definition
Unlock Bypass
00 = Not supported
01 = Supported
Address 52h defines the Secured Silicon Sector (Customer OTP Area) size in bytes. The sector size is two to the
power of N. For example, if the CFI data is 09h, the Secured Silicon Sector Size is 2 to the power of 9, which
equals 512 bytes.
Table 37. Secured Silicon Sector Size
Address
Data
Definition
52h
09h
Secured Silicon Sector (Customer OTP Area) Size
2N (bytes)
Address 53h defines the software features supported in the flash device. Each bit represents a software feature; a
‘1’ specifies that it is supported, while a ‘0’ specifies that it is not supported. The software features are defined as
below:
Bit 0: status register polling (1 = supported, 0 = not supported)
Bit 1: DQ polling (1 = supported, 0 = not supported)
Bit 2: New program suspend/resume commands (1 = supported, 0 = not supported)
Bit 3: Word programming (1 = supported, 0 = not supported)
Bit 4: Bit-field programming (1 = supported, 0 = not supported)
Bit 5: Autodetect programming (1 = supported, 0 = not supported)
Bit 6: RFU
www.cypress.com
Document No. 001-98488 Rev. *C
10
Quick Guide to Common Flash Interface
Bit 7: multiple writes per Line (1 = supported, 0 = not supported)
Table 38. Software Features
Address
Data
53h
8Fh
Definition
Software features
Address 54h defines the Page Size in bytes. The Page Size is two to the power of N. For example, if the CFI data
is 05h, the Page Size is 2 to the power of 5, which equals 32 bytes.
Table 39. Page Size
Address
Data
54h
05h
Definition
Page Size = 2N bytes
Address 55h defines the Erase Suspend Maximum Timeout time in us. The maximum timeout time is 2 to the
power of N. For example, if the CFI data is 06h, the Erase Suspend Maximum Timeout time is 2 to the power of 6,
which equals 64 s.
Table 40. Erase Suspend Maximum Timeout
Address
55h
Data
06h
Definition
Erase Suspend Timeout Maximum <
2N (s)
Address 56h defines the Program Suspend Maximum Timeout time in s. The maximum timeout time is 2 to the
power of N. For example, if the CFI data is 06h, the Program Suspend Maximum Timeout time is 2 to the power of
6, which equals 64 s.
Table 41. Program Suspend Maximum Timeout
Address
Data
Definition
56h
06h
Program Suspend Timeout Maximum
< 2N (s)
Addresses 5Ch to 77h are added to define the “Bank Region Information” – the number of sectors in the bank for
Bank 5 to Bank 32.
Address 78h defines the Embedded Hardware Reset Maximum Timeout time in s. Embedded Hardware Reset
refers to a reset with the Reset Pin. The maximum timeout time is 2 to the power of N. For example, if the CFI data
is 06h, the Embedded Hardware Reset Maximum Timeout time is 2 to the power of 6, which equals 64 s.
Table 42. Embedded Hardware Reset Maximum Timeout
Address
Data
78h
06h
Definition
Embedded Hardware Reset Timeout
Maximum < 2N (s)
Address 79h defines the Non-Embedded Hardware Reset Maximum Timeout time in s. Non-Embedded
Hardware Reset refers to Power-on-Reset. The maximum timeout time is 2 to the power of N. For example, if the
CFI data is 09h, the Non-Embedded Hardware Reset Maximum Timeout time is 2 to the power of 9, equals to
512 s.
Table 43. Non-Embedded Hardware Reset Maximum Timeout
Address
79h
3.5
Data
09h
Definition
Non-Embedded Hardware Reset
Timeout Maximum < 2N (s)
Alternate Vendor-Specific Extended Query
Cypress parallel NOR devices do not have Alternate Vendor-Specific Extended Query table implemented.
Currently only SPI FL-S and FS-S families implement this feature.
www.cypress.com
Document No. 001-98488 Rev. *C
11
Quick Guide to Common Flash Interface
In FL-S and FS-S, Addresses 51h to 53h define the ASCII string “ALT”. The string ALT indicates the beginning of
the Alternate Vendor-Specific Extended Query table.
Table 44. Alternate Vendor-Specific Extended Query String
Address
Data
Definition
51h
41h
'A' in ASCII
52h
4Ch
'L' in ASCII
52h
54h
'T' in ASCII
Addresses 54h and 55h define the Major and Minor version numbers of the Alternate Vendor-Specific Extended
Query implemented.
Table 45. Alternate Vendor-Specific Extended Query Version
Address
Data
54h
32h
Definition
Major version number = 2, ASCII
55h
30h
Minor version number = 0, ASCII
52h
54h
'T' in ASCII
For more detail parameter definitions, see the FL-S and FS-S datasheets.
4
Conclusion
This application note provides the user with an understanding of how to derive the CFI table data, which are listed
in Cypress Parallel NOR and SPI (FL-S and FS-S) flash data sheets.
Cypress supports the CFI tables in all parallel NOR Flash families and FL-S, FS-S SPI flash families.
www.cypress.com
Document No. 001-98488 Rev. *C
12
Quick Guide to Common Flash Interface
Document History Page
Document Title: AN98488 - Quick Guide to Common Flash Interface
Document Number: 001-98488
Orig. of Submission
Rev.
ECN No.
Description of Change
Change
Date
**
03/28/2008 Initial release
*A
06/05/2008 Minor update to Section 3.3; Changes to Table 3.23
*B
4909544
YOQI
09/05/2015 Updated in Cypress template
*C
4922334
MSWI
09/16/2015 Edited the document
www.cypress.com
Document No. 001-98488 Rev. *C
13
Quick Guide to Common Flash Interface
Worldwide Sales and Design Support
Worldwide Sales and Design Support
Cypress maintains a worldwide network of offices, solution centers, manufacturers’ representatives, and distributors. To find the
office closest to you, visit us at Cypress Locations.
#
999
Products
PSoC® Solutions
Automotive..................................cypress.com/go/automotive
psoc.cypress.com/solutions
Clocks & Buffers ................................ cypress.com/go/clocks
PSoC 1 | PSoC 3 | PSoC 4 | PSoC 5LP
Interface......................................... cypress.com/go/interface
Cypress Developer Community
Lighting & Power Control ............cypress.com/go/powerpsoc
Memory........................................... cypress.com/go/memory
PSoC ....................................................cypress.com/go/psoc
Touch Sensing .................................... cypress.com/go/touch
Community | Forums | Blogs | Video | Training
Technical Support
cypress.com/go/support
USB Controllers ....................................cypress.com/go/USB
Wireless/RF .................................... cypress.com/go/wireless
MirrorBit®, MirrorBit® Eclipse™, ORNAND™, EcoRAM™ and combinations thereof, are trademarks and registered trademarks of Cypress Semiconductor Corp. All
other trademarks or registered trademarks referenced herein are the property of their respective owners.
Cypress Semiconductor
198 Champion Court
San Jose, CA 95134-1709
Phone:
Fax:
Website:
408-943-2600
408-943-4730
www.cypress.com
© Cypress Semiconductor Corporation, 2008-2015. The information contained herein is subject to change without notice. Cypress Semiconductor Corporation
assumes no responsibility for the use of any circuitry other than circuitry embodied in a Cypress product. Nor does it convey or imply any license under patent or
other rights. Cypress products are not warranted nor intended to be used for medical, life support, life saving, critical control or safety applications, unless pursuant
to an express written agreement with Cypress. Furthermore, Cypress does not authorize its products for use as critical components in life-support systems where a
malfunction or failure may reasonably be expected to result in significant injury to the user. The inclusion of Cypress products in life-support systems application
implies that the manufacturer assumes all risk of such use and in doing so indemnifies Cypress against all charges.
This Source Code (software and/or firmware) is owned by Cypress Semiconductor Corporation (Cypress) and is protected by and subject to worldwide patent protection (United States and foreign), United States copyright laws and international treaty provisions. Cypress hereby grants to licensee a personal, non-exclusive,
non-transferable license to copy, use, modify, create derivative works of, and compile the Cypress Source Code and derivative works for the sole purpose of creating
custom software and or firmware in support of licensee product to be used only in conjunction with a Cypress integrated circuit as specified in the applicable agreement. Any reproduction, modification, translation, compilation, or representation of this Source Code except as specified above is prohibited without the express written permission of Cypress.
Disclaimer: CYPRESS MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARD TO THIS MATERIAL, INCLUDING, BUT NOT LIMITED
TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Cypress reserves the right to make changes without
further notice to the materials described herein. Cypress does not assume any liability arising out of the application or use of any product or circuit described herein.
Cypress does not authorize its products for use as critical components in life-support systems where a malfunction or failure may reasonably be expected to result in
significant injury to the user. The inclusion of Cypress' product in a life-support systems application implies that the manufacturer assumes all risk of such use and in
doing so indemnifies Cypress against all charges.
Use may be limited by and subject to the applicable Cypress software license agreement.
www.cypress.com
Document No. 001-98488 Rev. *C