Datasheet

Ultra subminiature Toggle Switch
A9TS
Ultra subminiature size.
• Gold-plated clip contact ensure high reliability.
• The sealed bottom prevents flux penetration.
• Washable, equivalent to IP64 (IEC-60529).
• A9TS is smaller than A9T.
Height: A9T 17mm A9TS 11mm (35% smaller than A9T)
RoHS Compliant
Typical Applications
Security Control Boards
Electric Power Instrumentation
Program Controllers
■
List of Models
Actuator Shape
Standard
Terminal Shape
DIP Terminal
Right Angle Terminal
Vertical Mount Terminal
Switching Functions
SPDT
DPDT
SPDT
DPDT
SPDT
DPDT
A9TS21-0013
ON
−
ON
A9TS11-0011
A9TS21-0011
A9TS11-0012
A9TS21-0012
A9TS11-0013
ON
OFF
ON
A9TS12-0011
A9TS22-0011
A9TS12-0012
A9TS22-0012
A9TS12-0013
Quantity per tray
Note:
100
25
A9TS22-0013
50
1. Lever do not stop at "-" position.
2. Switching Functions show the view from the side of Type and Brand name marking.
■
Ratings/Characteristics
Rating (resistive load)
14 mA at 28 VAC/DC, 0.1 μA (minimum current) at 20 mVAC/DC
Ambient operating temperature
−20 °C to +80 °C 60% RH max. (with no icing or condensation)
Ambient operating humidity
45 to 85% RH (at +5 to +35 °C)
Insulation resistance
500 MΩ min. (at 500 VDC with insulation tester)
Contact resistance (initial value)
80 mΩ max.
Dielectric strength
500 VAC for 1min between terminals, between terminals and ground
Vibration resistance
Malfunction
10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
Malfunction
500 m/s2 min.
Durability
Mechanical
50,000 operations min.
Electrical
50,000 operations min.
Degree of protection
IEC IP64
Washing
Possible
Operating forcse
4.9 N max.
Weight
0.3 g
1
A9TS
A9TS
■
Dimensions
●
DIP Terminal Models
(Unit: mm)
11
3.8
1.6
2.54
0.3
(5.6)
1.7 dia.
0.2 0.45
(6)
2.54
28°±4°
7
2.54
(4)
●
(6)
(3)
(2)
(5)
(2)
(1)
(4)
(1)
Single Pole Type
Marking Side
Note:
(3)
Double Pole Type
NO.(4) and (6) terminals in the SPDT models are dummys to support the Switch case.
Right Angle Terminal Models
11
3.8
1.6
(5.6)
1.7 dia.
0.2
0.45
2.54
28°±4°
2.54
7
(3)
(6)
(3)
(2)
(5)
(2)
(1)
(4)
(1)
Single Pole Type
Marking Side
Double Pole Type
0.3
2.6 3.1
5.08
●
2.54
Vertical Mount Terminal Models
11
3.8
1.6
2.54
0.3
(5.6)
1.7 dia.
28°±4°
7
Marking Side
2
(6)
(3)
(2)
(5)
(2)
(1)
(4)
(1)
0.45
5.08
Note:
(3)
2.54
2.54
Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Single Pole Type
Double Pole Type
A9TS
■
A9TS
PCB Dimensions (Top View)
DIP Terminal Models
Right Angle Terminal Models
2.54
Five-0.6 +0.1
0 dia.
(4)
(4)
(1)
(3)
Five-0.6 +0.1
0 dia.
(3)
5.08
(2)
(6)
Single Pole Type
5.08
(1)
(5)
5.08
(2)
(6)
2.54
Six-0.6 +0.1
0 dia.
(2)
2.54
Eight-0.6 +0.1
0 dia.
(3)
(6)
(2)
(5)
(1)
(4)
5.08
(1)
(3)
Double Pole Type
5.08
Single Pole Type
5.08
Double Pole Type
Vertical Mount Terminal Models
2.54
2.54
5.08
5.08
(1)
(2)
(4)
(1)
(5)
(2)
(6)
(3)
5.08
(3)
Eight-0.6 +0.1
0 dia.
Five-0.6 +0.1
0 dia.
Single Pole Type
■
5.08
Double Pole Type
Switching Function / Internal Connections
Switching Functions
ON
−
ON
2
SPDT Models
ON
OFF
3
1
ON
3
3
2
1
2
1
ON
−
ON
2
DPDT Models
5
ON
OFF
ON
3
1
6
2
2
4
5
Note:
3
1
6
4
5
3
1
6
4
Lever do not stop at "−" position.
3
A9TS
A9TS
■ Safety Precautions
Be sure to read the Safety precautions common to all PCB-mount Manual Switch for correct use.
● Cautions
Use the switch within the rated voltage and current ranges,
otherwise the Switch may have a shortened life expectancy,
radiate heat,or burn out. This particularly applies to the
instantaneous voltages and currents when switching.
● Using Flux
Making mistakes in the type of flux or in the amount or method in
which it is applied can cause flux to enter the interior of the
Switch, with adverse effects on Switch performance. Assess the
proper flux, conditions,and methods prior to using it.
● Hardling
Do not apply excessive operating force to the Switch. Otherwise
the Switch may be damaged or deformed, and the switch
mechanism may malfunction as a result. Apply an operating force
not exceeding 9.8N {1,000gf}. Apply the operating load from the
top of the actuator. Do not apply a load from angle or from side
the actuator. Doing so may deform the Switch contact.
● RoHS Compliant
The "RoHS Compliant" designation indicates that the listed
models do not contain the six hazardous substances covered by
the RoHS Directive.
Reference: The following standards are used to determine
compliance for the six substances.
• Lead:
1,000 ppm max.
• Mercury:
1,000 ppm max.
• Cadmium:
100 ppm max.
• Hexavalent chromium: 1,000 ppm max.
• PBB:
1,000 ppm max.
• PBDF:
1,000 ppm max.
● Soldering
Observe the following conditions when soldering the Switch.
Automatic Soldering Bath
Soldering temperature: 260 °C max. (Preheating: 100 °C 120s max.)
Soldering time: 5s max.
Manual Soldering
Soldering temperature: 350 °C at the tip of the soldering iron.
Soldering time: 3s max.
● Washing
Apply alcohol based solvents to clean.
Do not clean the Switch immediately after soldering. Wait for at
least five minutes after soldering before cleaning.
Ultrasonic cleaning is not available dip into Switch washing
agents for two minutes maximum.
● Environment for Storage and Use
To prevent discoloration of the terminals and other problems
during storage, do not store the Switch in locations subject to the
following conditions.
1. High temperature or humidity
2. Corrosive gases
3. Direct sunlight
Also, the Switch is not waterproof or splash-resistance.
Do not use the Switch in locations that are subject to contact with
water. Do not subject the Switch to freezing or condensation.
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. A199-E1-04
1014(0207)(O)