OSRAM
BU LLS SSL AP
PrevaLED SKY Ourdoor module
Datasheet
The PrevaLED SKY is a high power LED module with integrated heat sink for optimal thermal management
and tailored optical design. The modular design concept of PrevaLED SKY allows for design flexibility by varying
the module quantity to achieve the best street lighting solution for difference application from Road lighting to
Area lighting. The LED module is available in different color temperature (4000K and 6500K), offering very
long time lifetime for minimal maintenance. PrevaLED SKY is an IP66 unit ideal for outdoor applications.
BENEFITS

Tailored optical design
- Special designed lenses optimized the light distribution across the road for different road class
requirements and also difference application required Highbay, Lowbay and Area floodlight illumination.

IP66 protection
- Self contained housing with heat sink for excellent thermal management, no extra protection is needed

High energy efficiency
- Constant current driven maximizing system efficiency

Stackable & maintainable module
- Simple screw fixing module allowing multiple module configuration in luminaires

Long life time
- Optimized for extended lifetime and lumen maintenance
APPLICATIONS

Street lighting for ME1 and ME2 road classes

Area illumination for Highbay, Lowbay, Canopy light, Billboard light and Floodlight
SPECIFICATION
PrevaLED SKY Datasheet
Version 1.1
Date: 1 July 2015
Page 1 of 7
OSRAM
BU LLS SSL AP
PrevaLED SKY
Light
Output *
Parameter
Typical luminous flux
@700mA
Luminous flux range
@700mA
Optical
CCT
LP
HP
3000 lm
6000 lm
2590~3319 lm
5179~6637 lm
150ºx 80ºT40ºS (For Single-sided / Opposite mount)
150ºx 80ºT40ºC (For Twin-central mount)
60ºx 60º
100ºx 100º
100ºx 60º
4000K
6500K
Typical CRI (Ra)
Lifetime (L70/B50)
Electrical
70
70
50,000 hours (Tc @ 70ºC)
69.6V DC
Input voltage range
33~38.2V DC
66~76.4V DC
25W
50W
Recommended Driver
OSRAM OPTOTRONIC
OT 50/120-277/700 P5
OT 100/120-277/700 P5
OT 180/120-277/700 P5
OT 250/120-277/700 P5
ESD Protection
contact 4kV and air 8kV
Dimension
220mmL x 70mmW x 66mmH
screw fixing at side brackets
Optics
Weight
polycarbonate lens
350±30g
-30 … 85ºC (measure at Tc point)
Storage temp. range ##
*
400±30g
-30 … 50ºC (Ta in free air)
-30 … 80ºC (measure at Tc point) for HP
-30 … 70ºC (measure at Tc point) for LP
Ambient temp. range
Operating (case) temp. range
##
Standard
Compliance
50,000 hours (Tc @ 80ºC)
34.8V DC
Mounting
Temperature
6500K
Typical input voltage
Power @700mA( typical)
Mechanical
4000K
IP Rating
IP66
Standard
IEC 62471; EN 60529; EN 62031;IEC 60598-1; EN 55015; EN 61547
Flammability
IEC 60598-1
Environment
RoHS
Due to the special conditions of manufacturing processes of LED, the typical data of technical parameters can only reflect statistical figures and do
not necessarily correspond to the actual parameters of each single product. Actual lumen output can be varied due to many factors like lamp factor of LED,
input current/voltage, thermal conditions, many other optical tolerance, and measurement tolerance. The data above is for reference only. Please contact
Osram sales or marketing staff for advice if customers has any specific demand on particular parameters. Ranking at Ta = 25°.Tolerance of measurements
for the colour rendering Ra is ±2.
## Exceeding maximum ratings for operation and storage temperature will reduce expected life time or destroy the LED module. The temperature of the LED
module needs to be measured at the Tc-point according to EN60598-1 in a thermally constant status with a temperature sensor or a temperature sensitive
label.
PrevaLED SKY Datasheet
Version 1.1
Date: 1 July 2015
Page 2 of 7
OSRAM
BU LLS SSL AP
PHOTOMETRICS
Note: The distribute curve is tested by 6500K module with brightness bin: NP.
Due to the special conditions of manufacturing processes of LED, the polar candela distribution and distance illuminance can only reflect statistical figures and
do not necessarily correspond to the actual parameters of each single product. The actual data may differ from the typical data.
PrevaLED SKY Datasheet
Version 1.1
Date: 1 July 2015
Page 3 of 7
OSRAM
BU LLS SSL AP
SALES & TECHNICAL SUPPORT
1. Application with OT 100/120-277/700 P5:
.
2 pcs PrevaLED Sky Modules Connect with OT 100/120-277/700 P5
(Example just for module series connection) :
2. Driver combination matrix.
PrevaLED SKY Datasheet
Version 1.1
Date: 1 July 2015
Page 4 of 7
OSRAM
BU LLS SSL AP
3. Application of installation for module orientation (make sure temperature no exceed tc
value)
Recommend application:
0~360°is recommended as show
4. Application of installation sketch map for optics.
PrevaLED SKY Datasheet
Version 1.1
Date: 1 July 2015
Page 5 of 7
OSRAM
BU LLS SSL AP
DRAWINGS
ORDERING CODE
Product group
PrevaLED SKY
PrevaLED SKY
PrevaLED SKY
PrevaLED SKY
PrevaLED SKY
Product name
PL-SKY-HP 765L150X80T40C70V12X1APACOSRAM
PL-SKY-HP 765L150X80T40S70V12X1APACOSRAM
PL-SKY-HP 765 L60X60 70V 12X1 APAC OSRAM
PL-SKY-HP 765 L100X100 70V 12X1APACOSRAM
PL-SKY-HP 765 L100X60 70V 12X1 APACOSRAM
EAN-10
4052899328013
4052899328037
4052899328051
4052899328075
4052899328099
S-Unit
1
1
1
1
1
EAN-40
4052899328020
4052899328044
4052899328068
4052899328082
4052899328105
S-Unit
12
12
12
12
12
PrevaLED SKY
PrevaLED SKY
PrevaLED SKY
PrevaLED SKY
PrevaLED SKY
PrevaLED SKY
PL-SKY-HP 740L150X80T40C70V12X1APACOSRAM
PL-SKY-HP 740L150X80T40S70V12X1APACOSRAM
PL-SKY-HP 740 L60X60 70V 12X1 APAC OSRAM
PL-SKY-HP 740 L100X100 70V 12X1APACOSRAM
PL-SKY-HP 740 L100X60 70V 12X1 APACOSRAM
PL-SKY-HP 840 L150X80T40S 70V 12X1KOSRAM
4052899328112
4052899328136
4052899328150
4052899328174
4052899328198
4052899328112
1
1
1
1
1
1
4052899328129
4052899328143
4052899328167
4052899328181
4052899328204
4052899328426
12
12
12
12
12
12
PrevaLED SKY
PrevaLED SKY
PrevaLED SKY
PrevaLED SKY
PrevaLED SKY
PL-SKY-LP 765L150X80T40C35V12X1APACOSRAM
PL-SKY-LP 765L150X80T40S35V12X1APACOSRAM
PL-SKY-LP 765 L60X60 35V 12X1 APAC OSRAM
PL-SKY-LP 765 L100X100 35V 12X1APACOSRAM
PL-SKY-LP 765 L100X60 35V 12X1 APACOSRAM
4052899328211
4052899328235
4052899328259
4052899328273
4052899328297
1
1
1
1
1
4052899328228
4052899328242
4052899328266
4052899328280
4052899328303
12
12
12
12
12
PrevaLED SKY
PrevaLED SKY
PrevaLED SKY
PrevaLED SKY
PrevaLED SKY
PL-SKY-LP 740L150X80T40C35V12X1APACOSRAM
PL-SKY-LP 740L150X80T40S35V12X1APACOSRAM
PL-SKY-LP 740 L60X60 35V 12X1 APAC OSRAM
PL-SKY-LP 740 L100X100 35V 12X1APACOSRAM
PL-SKY-LP 740 L100X60 35V 12X1 APACOSRAM
4052899328310
4052899328334
4052899328358
4052899328372
4052899328396
1
1
1
1
1
4052899328327
4052899328341
4052899328365
4052899328389
4052899328402
12
12
12
12
12
PrevaLED SKY Datasheet
Version 1.1
Date: 1 July 2015
Page 6 of 7
OSRAM
BU LLS SSL AP
SAFETY NOTE

The LED module itself and all its components may not be mechanical stressed.

The module net weight of HP version is 400±30g, LP version is 350±30g.

Assembly must not damage or destroy conducting paths on the circuit board.

To avoid mechanical damage to the connecting cables, the module should be attached securely to the
fixture. Heavy vibration should be avoided.

Installation of LED modules with (power supplies) needs to be made with regard to all applicable
electrical and safety standards. Only qualified personnel should be allowed to perform installation.

Please ensure that the power supply is of adequate power to operate the total load.

PrevaLED SKY outdoor module needs to be connected with constant current DC driver which must has
stable constant current (+/-10% tolerance suggested) output.

Electrical contact is achieved with the contact cables.

The design of the housing should be according to the IP standards in the application.

Pay attention to standard ESD precautions when installing the module.

If surge protection structure not within power supplier, a lightening protector should be needed
additionally for outdoor application.


The insulation designed working voltage U-out is 500V for this module.
The product was designed as built-in LED module which can only fulfil basic insulation. It should be
applicable to Class I luminaires. If it is used in Class II luminaires, the final user should make sure the
safety protection in final luminaires construction.

tc value is 80 centigrade for HP type LED module, 70 centigrade for LP type LED module, higher tc
application is not recommended.
OSRAM Asia Pacific
5th Floor Hantang Building, OCT,
Shennan Ave, Nan Shan District,
518053, Shenzhen, Guangdong, P.R. China
www.osram.com
PrevaLED SKY Datasheet
Version 1.1
Date: 1 July 2015
Sales and technical support is given by the
local OSRAM subsidiaries. Complete
subsidiaries listing is available at OSRAM
homepage.
Page 7 of 7