DRP BN1PH Series 6 0 - 4 8 0 W AT T S A C / D C D I N R A I L FEATURES • • • • • • • • • • • 24VDC 60W - 480W 1Ph AC/DC Power Supply DIN Rail Mountable Power will not de-rate for the entire input voltage range Power Boost of 150% for 3 seconds Conformal coating on PCBAs To protect against common dust and chemical pollutants Operating Temp -25C to 80C MTBF DRP60W & 120W > 800 000hrs MTBF DRP240W & 480W > 500 000hrs Overvoltage / Overcurrent / Over Temperature / Protection SPECIFICATIONS OUTPUT ENVIRONMENTAL Output Voltage 24Vdc, 48Vdc Operating Temperature -25°C to +80°C Output Voltage Range 24V - 28Vdc, 48V-56Vdc Storage Temperature -25°C to +85°C Output Current See Selection Table Power De-rating > 50°C (2.5% / °C) Indicator Green LED (DC OK) Operating Humidity < 95% RH (Non-Condensing) Output Power 60W - 480W, See Selection Table Operating Altitude 2,500m Line Regulation < 0.5% typ. (@ 85-264Vac input, 100% load) Load Regulation < 1% typ. (@ 85-264Vac input, 0-100% load) PARD (20MHz) < 200mVpp Hold-up Time > 20ms @ 115Vac & 230Vac INPUT Input Voltage Range 85–264VAC 120-375 VDC Input Frequency Efficiency at 100% Load 47-63Hz DRP60: <0.8A @ 230Vac DRP120: < 1.2A @ 230Vac DRP240: < 1.3A @ 230Vac DRP480: <3A @ 230Vac > 91.0% @ 115VAC >93.0% @ 230VAC Leakage Current < 1mA @ 240VAC Input Current MECHANICAL Case Cover Aluminium Dimensions / Weight DRP60: 121 x 32 x 119.3mm, 0.33Kg DRP120: 121 x 32 x 123.1mm, 0.72kg DRP240: 121 x 85 x 124.1mm, 1.1kg DRP480: 121 x 144 x 118.6mm, 1.37kg Indicator Green LED (DC OK) Input Terminal 3 Pins (Rated 300V/30A) Output Terminal 4 Pins (Rated 300V/30A) Input Wire DRP60: AWG 22-12 DRP120: AWG 20-12 DRP240: AWG 16-14 DRP480, AWG 18-10 Output Wire DRP60: AWG 22-12 DRP120: AWG 20-12 DRP240: AWG 16-14 DRP480: AWG 18-10 Mounting Rail TS35 DIN Rail in accordance with EN60715 IEC AC Input See PBB1P Series for IEC Input option See PBB1P Series for Drip Hood Cover option PROTECTIONS Overvoltage 32V, +/-10% SELV Ouput, Hiccup Mode, NonLatching (Auto-Recovery) Overload/Overcurrent > 150% of rated load current, Hiccup Mode, NonLatching (Auto-Recovery) Over Temperature < 80C Surrounding Air Temperature @ 100% load, Non-Latching (Auto Recovery) Short Circuit Hiccup Mode, Non-Latching (Auto-Recovery) when the fault is removed) Drip Hood Cover Degree of Protection IP20 C-Tick AS/NZS CISPR11 Group 1 Class A. Protection against shock Class 1 with PE (Primary Earth) connection Input to Output: 4.0KVAC Input to Ground: 1.5KVAC Output to Ground: 1.5KVAC Electronic Equipment EN50718 / IEC62103 in Power Installatioins Electrical Safety SIQ to EN60950-1, UL/cUL recognized to UL60950-1, CSA C22.2 No. 60950-1, CB scheme to IEC60950-1 Industrial Control UL/cUL listed to UL508 and CSA C22.2 No. 107.101, CSA to CSA C22.2 No. 107.1-01 (File No. 181564) CE In conformance with EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC Materials & Parts RoHS Directive 2011/65/EU Compliant Galvanic Isolation STANDARDS RELIABILITY MTBF Expected Life Time 1 DRP60W & DRP20W: 800,000 hrs as per Telcordia SR-332 I/P: 115Vac, O/P: 100% load, Ta 25C DRP240W & DRP480W: 500,000 hrs as per Telcordia SR-332 I/P: 115Vac, O/P: 100% load, Ta 25C 10 years (230Vac 50% load @ 40C) Doc. No. DRP BN1PH Series Rev.A 16-9-15 DRP BN1PH Series 6 0 - 4 8 0 W AT T S A C / D C D I N R A I L SELECTION TABLE MODEL NUMBER OUTPUT VOLTAGE OUTPUT CURRENT POWER BOOST (5 SECS) OUTPUT POWER DRP024V060W1BN 24Vdc 2.5A 3.75A 60W DRP024V120W1BN 24Vdc 5A 7.5A 120W DRP024V240W1BN 24Vdc 10A 15A 240W DRP024V480W1BN 24Vdc 20A 30A 480W DRP048V060W1BN 48Vdc 1.25A 1.8A 60W DRP048V120W1BN 48Vdc 2.5A 3.75A 120W DRP048V240W1BN 48Vdc 5A 7.5A 240W DRP048V480W1BN 48Vdc 10A 15A 480W TECHNICAL ILLUSTRATIONS Doc. No. DRP BN1PH Series Rev.A 16-9-15 Powering Progress – www.powerbox.com.au 2