4 8 0 W S i n g l e O u t put Industrial DIN RAIL with PFC Function
DRP480
series
Built-in Passive PFC Function Compliance to EN61000-3-2
Protections:Short Circuit/Over Load/Over Voltage/ Over
Temperature
High Efficiency 89% and Low Dissipation
Cooling by Free Air Convection
Built-in Constant Current Limiting Circuit
Can be Installed on DIN Rail TS-35/7.5 or 15
UL 508 (Industrial Control Equipment) Approved
EN61000-6-2 (EN50082-2) Industrial Immunity Level
AC Input Range Selectable by Switch (DRP480S)
Model Number
Input Volts
Output Volts Output Amps
Over Voltage Protection
DRP480-24
DRP480-48
180-264VAC
180-264VAC
24 VDC
48VDC
0-20 Amps
0-10 Amps
30~36 Volts(DC)
54~60 Volts(DC)
DRP480S-24
DRP480S-48
90-132/180-264VAC 24 VDC
90-132/180-264VAC 48VDC
0-20 Amps
0-10 Amps
30~36 Volts(DC)
59~66 Volts(DC)
SINGLE OUTPUT
All specifications are typical at nominal input, full load, and 25°C unless otherwise noted
WWW.ASTRODYNE.COM
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
4 8 0 W S i n g l e O u t put Industrial DIN RAIL with PFC Function
INPUT SPECIFICATIONS
Input Voltage Range
DRP480
180~ 264VAC
DRP480S
90-132/180-264VAC by Switch
Frequency Range
47-63 Hz
Inrush Current, typ: (cold start)
DRP480
40 Amps / 230VAC
DRP480S
27A / 115VAC; 45A / 230VAC
Input Current
DRP480
4.0 Amps. @ 230VAC
DRP480S
8A / 115VAC; 3.2A / 230VAC
Leakage current
< 3.5mAmps / 240VAC
Power Factor @ FL
PF ≥ 0.7 230VAC Only
EMI
Harmonic Current
Efficiency
Isolation
EMS
DRP480
series
DRP480: EN55022B (CISPR22B)
DRP480S:EN55011(CISPR11); EN55022
(CISPR22) EN61204-3 Class B
Compliance to EN61000-3-2,-3
89%
4242VAC Input - Output
2121VAC Input - Ground
707VAC Output - Ground
Compliance to
EN61000-4-2,3,4,5,6,8,11; ENV50204,
EN61204-3 (DRP480S only)
EN61000-6-2 (EN50082-2)
light Industry Level, Criteria A
ENVIRONMENTAL SPECIFICATIONS
OUTPUT SPECIFICATIONS
Voltage and Current Line Regulation
Load Regulation
Voltage Tolerance (Note 2)
Ripple/Noise (Note 1)
Hold Up Time @ FL
Setup, Rise Time @ FL
Over Voltage Protection
Over Current Protection
Over Temperature Protection
DC Voltage Adjust
See Selection Chart
±0.5%
±1.0%
±1.0%
120mVpk-pk max.
DRP480: 16mS; DRP480S: 23mS
1200ms, 40mS
See Selection Chart
Shut down o/p voltage,re-power
105 ~ 150% rated output power
Constant current limiting, auto recover
100°C ±5°C (TSW: Detected on
heatsink of power switch)
Shut down o/p voltage, re-power
after cool down
24~28Volts: 24Vout
48~53Volts: 48Vout (48-55V DRP480S)
Oper. Temperature
Storage Temperature
Relative Humidity
Temperature Coefficient
MTBF
Vibration
MTBF (MIL-HDBK-217F)
-20°C to +70°C (See Dreate Curve)
DRP480: -20°C to +85°C, 10~95% RH
DRP480S: 20°C to +85°C, 10~95% RH
20~90% RH non cond
±0.03% / °C (0-50°C)
180.9KHrs min,MIL-HDBK-217F(25°C)
10~500Hz, 2G10min./1cycle, period for
60min. each along X, Y, Z axes
Mounting: Compliance to IEC60068-2-6
DRP480: 180.9K Hrs.
DRP480S: 187.9K Hrs.
PHYSICAL SPECIFICATIONS
Size
Millimeters
Inches
Weight
227 x 125.2 x 100
8.94” x 4.93 ” x 3.94 ”
DRP480: 5.29 lb (2400g)
DRP480S: 7.73 lb (2600g)
GENERAL SPECIFICATIONS
Notes
Safety
Insulation Resistance
1. Ripple & noise are measured at 20MHz of bandwidth by using a 12”
twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
2. Tolerance : includes set up tolerance, line regulation and load regulation.
UL508, UL60950-1, TUV EN60950-1
≥ 100MΩ / 500Volts / 25°C / 70% RH