Datasheet

D3C
Ultra Subminiature Detection Switch
㧰
Ultra Subminiature
Detection Switch with Slide
Mechanism and Lever
Actuator
● Compact and light weight with 3-mm long stroke.
3
C
● Built-in slide mechanism allows selection of
shorting or non-shorting switching timing to
match the application.
RoHS Compliant
Model Number Legend
Contact Form
2 0
1 2@
D3C-@
●SPDT
1. Switching timing
1 : Non-shorting Model
2 : Shorting Model
2. Maximum Operating Force (OF)
1 : 1.28N {130 gf}
NO COM NC
3
2 : 0.39N {40 gf}
Contact
1.28 N {130 gf} (Standard)
0.39 N {40 gf} (Low force)
Non-shorting
Shorting
Non-shorting
Shorting
D3C-1210
D3C-2210
D3C-1220
D3C-2220
Ratings
Specification
Slide
Material
Silver plated
Minimum applicable load
(reference value) *
*
Rotary lever
2
Contact Specifications
List of models
Operating Force (OF)
Switching timing
Actuator
1
5 VDC 1 mA
Please refer to "●Using Micro Loads" in "Precautions"
for more information on the minimum applicable load.
Characteristics
Rated voltage
Resistive load
30 VDC
0.1 A
Note. The above rating values were applied under the
following test conditions.
(1) Ambient temperature: 20±2°C
(2) Ambient humidity: 65±5% RH
(3) Operating frequency: 30 operations/min
Permissible operating speed
Permissible operating
frequency
Mechanical
Electrical
Insulation resistance
Vibration resistance *1
Shock resistance
50 mΩ max.
Between terminals of the same
polarity
250 VAC 50/60 Hz for 1 min
Between current-carrying
metal parts and ground
250 VAC 50/60 Hz for 1 min
Malfunction
Durability
Malfunction *1
Durability *2
Degree of protection
Ambient operating temperature
Ambient operating humidity
Weight
30 operations/min
100 MΩ min. (at 250 VDC with insulation tester)
Contact resistance (initial value)
Dielectric strength
1 mm to 500 mm/s
200 operations/min
10 to 55 Hz, 1.5 mm double amplitude
1,000 m/s2 {approx. 100G} max.
300 m/s2 {approx. 30G}max.
50,000 operations min. (30 operations/min)
IEC IP00
-20 to +80°C (at ambient humidity 60% max.)
(with no icing or condensation)
85% max. (for +5 to +35°C)
Approx. 0.3g
Note. The data given above are initial values.
*1. The given values apply for Total Travel Position. Close or open circuit of the contact is 1 ms max.
*2. For testing conditions, consult your OMRON sales representative.
1
D3C
Ultra Subminiature Detection Switch
Mounting Holes (Unit: mm)
M1.6 Tap
4±0.1
5.7±0.1
1.6 dia. holes
Dimensions (Unit: mm) and Operating Characteristics
3
C
B
A
5.6
4.2
1dia. holes
1.6+0.12
dia.
0
8.7
6.7
5.7±0.15
holes
1.6
R1
FP
OP
6
4.7
Type Non-Shorting
Operating
Characteristics
4±0.15
4.6 max.
Model
Operating Force
OF
Max.
Releasing Force
RF
Min.
1
0.8
2.54 2.54
4
8
0.3
0.9
Shorting
D3C -1210
D3C -1220
1.28 N {130 gf}
(0.98 N {100 gf})
0.10 N {10 gf}
(0.15 N {15 gf})
0.39 N {40 gf} 1.28 N {130 gf}
(0.29 N {30 gf}) (0.98 N {100 gf})
0.03 N {3 gf}
0.10 N {10 gf}
(0.05 N {5 gf}) (0.15 N) {15 gf}
Free Position
Operating Position
0
1.5-0.15
dia.
3.5
FP Max.
OP1
OP2
Total Travel Position TTP
D3C -2210
4.8 mm
3.5±0.3 mm
2.5±0.3 mm
1.3±0.4 mm
D3C -2220
0.39 N {40 gf}
(0.29 N {30 gf})
0.03 N {3 gf}
(0.05 N {5 gf})
4.8 mm
3.4±0.3 mm
2.6±0.3 mm
1.3±0.4 mm
<PCB Mounting
Dimensions (Reference)>
2.54
Switching timing
3-1dia. holes
2.54
4.2
Non-shorting Model
FP
OP1
OP2
TTP
2(NC)
2(NC)
1
1
3(NO)
3(NO)
FP
Shorting Model
OP1
OP2
TTP
8
Note 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Note 2. The values for operating characteristics apply for operation in the A direction (straight line), and the values in parentheses indicate those for operation in the
B (rotary) direction for reference.
Precautions
★Please refer to "Common Precautions" for correct use.
Cautions
●Soldering
●Mounting Plate
For soldering time, we recommend to solder within 3 s at a
soldering iron temperature of under 350°C. Soldering at a
temperature exceeding 350°C, soldering for more than 3 s, or
repeated soldering will degrade the Switch characteristics.
Make sure that flux and liquid surface of the solder does not flow
over the edge of the board when soldering. Please complete
soldering a t a temperature of 260°C within 5 s.
It is also recommended
that you apply flux
Switch mounting surface
guard to the mounting
surface of the Switch.
Use materials other than ABS or polycarbonate for the mounting
plate. Since grease is used for the Switch, it may cause cracks if
grease from the Switch comes in contact with such materials.
Correct Use
●Mounting
Use M1.6 mounting screw with plane washers or spring washers
to securely mount the Switch. Tighten the screws to a torque of
4.9 to 9.8×10-2 N·m {0.5 to 1 kgf·cm}.
●Application of Operation Force to the Lever
●Using Micro Loads
Use models that operate in the following range. However, even
when using micro load models within the following operating
range, if inrush current occurs when the contact is opened or
closed, it may increase the contact wear and so decrease
durability. Therefore, insert a contact protection circuit where
necessary. The N-level reference value applies for the minimum
applicable load. This value indicates the malfunction reference
level for the reliability level of 60% (λ60). (JIS C5003)
The equation, λ60=0.5×10-6/operation indicates that the
1
estimated malfunction rate is less than 2,000,000 operations with
a reliability level of 60%.
Voltage (V)
㧰
D3C-1210, D3C-2210
D3C-1220, D3C-2220
30
100 mA
0.16 mA
24
Do not apply loads from any other directions other than operating
direction of the lever as shown in the following figure.
It may damage the Switch or cause malfunction.
Operating range
12
5
1 mA
0
0.1
1
10
100
1,000
Current (mA)
2
D3C
Ultra Subminiature Detection Switch
㧰
3
C
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY
Contact: www.omron.com/ecb
Cat. No. C099-E1-04
0812(0207)(O)
3