Datasheet

D2X
Detection Switch
A Switch with Crimp-type
Connectors that Greatly
Reduces Wiring Work
㧰
● Clip-on wiring via crimp-type connectors.
● Snap-fit attachment for easy installation.
2
X
● Operation possible from either side to enable
mounting in either direction.
RoHS Compliant
List of Models
Characteristics
Mode
Permissible operating speed
D2X-C
Permissible Mechanical
operating
frequency Electrical
Contact Form
Insulation resistance
Contact resistance (initial value)
●SPST-NC
Dielectric
strength
Vibration
resistance
Shock
resistance
Durability *
NC COM
Specification
Contact
Material
Minimum applicable load (reference value) *
*
Slide
5 VDC 1 mA
Please refer to "●Using Micro Loads" in "Precautions" for more
information on the minimum applicable load.
200 mΩ max.
Between current-carrying
metal parts and ground
250 VAC 50/60 Hz for 1 min
Malfunction
10 to 55 Hz, 1.5 mm double amplitude
Destruction
500 m/s2 {approx. 50G} max.
Malfunction
300 m/s2 {approx. 30G} max.
Mechanical
1,000,000 operations min. (60 operations/min)
Electrical
Ambient operating humidity
Weight
100 MΩ min. (at 250 VDC with insulation tester)
250 VAC 50/60 Hz for 1 min
Ambient operating temperature
Gold plated
60 operations/min
30 operations/min
Between terminals of the
same polarity
Degree of protection
Contact Specifications
0.1 mm to 100 mm/s
50,000 operations min. (30 operations/min)
IEC IP00
-10°C to +70°C (at ambient humidity
of 60% max.)
(with no icing or condensation)
45% to 85% (for +5°C to +35°C)
Approx. 1 g
Note. The data given above are initial values.
* For testing conditions, consult your OMRON sales representative.
Ratings
Rated voltage
Resistive load
30 VDC
0.1 A
Note. The above rating values apply under the following test conditions.
(1) Ambient temperature: 20±2°C
(2) Ambient humidity: 65±5%
(3) Operating frequency: 30 operations/min
1
D2X
Detection Switch
Mounting Holes (Unit: mm)
Refer to the following diagram for mounting hole dimensions, and make sure that the burr is placed to backside of Mounting Plate.
When thickness of the plate (t) is 1.6 mm.
When thickness of the plate (t) is 1.2 mm.
2-R0.6
4.8
8-R1
2-R0.6
12.9
1.8
8±0.1 3.5 dia.
3.2+0.1
0 dia.
2R0.5 4.4
2-R0.5 4.4
2-R0.5
3.2±0.05
+0.1
5.2 10.8 0
2R0.5
0.05 dia.
3.2±0.05
10.8+0.1
0
2-R1.6
㧰
4-R1
4
2
X
2.7±0.1
5
3.2+0.1
0
5
3.4
12.2
5
2-R0.6
2-R0.6
Note 1. Allowable deviation from the center is ±0.07 mm.
Note 2. Unless otherwise specified, a tolerance of ±0.1 mm applies to all dimensions.
Dimensions (Unit: mm) and Operating Characteristics
D2X-C
Direction A
TTP=MIN6.34
(Rotational angle equals 25°)
Stroke metrics
(Direction B) 2±0
OP=2.35 max.
(Rotational angle equals 9°)
Direction B
Boss of the reverse side
2-The center of 3.1 mm dia.
2±0
Operating Force
Releasing Force
Stroke metrics
(Direction A)
OP=0.52 min.
(Rotational angle equals 2°)
OF Max.
RF Min.
Operating Position
OP
Total Travel Position TTP Min.
4.8
0.49 N {50 gf}
0.02 N {2 gf}
0.52 to 2.35 mm
6.34 mm
(0.2)
Stroke metrics
1.55
Direction A
0.52 min.
2-3.1 dia.
15
Direction B
0.52 min.
Completely ON
Completely OFF
11.9
3.8
8
5.1
12.2
(17)
6
Total Travel
Position 6.34 min.
1
5.8
1.6
2.35 max.
Total Travel
Position 6.34 min.
Actuator stroke (mm)
*
* Dimensions of the marked parts are designed by Tyco
Electronics Japan. This part is identical to Tyco Electronics
Japan's CT connectors (dipole type) in size.
2.35 max.
3.3
0.4
6.2
5.3
Note 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Note 2. The operating characteristics are for cases where the actuator operates in the A (
) direction or B (
) direction.
Precautions
★ Please refer to "Basic Switches Common Precautions" for correct use.
Correct Use
●Terminal Connection
Do not use the Switch with Connector mounted and weight load
applied to the Connector and lead wire, otherwise it may rattle or
may result in connection failure.
Wiring Connector
• Use the CT Connector made by Tyco Electronics Japan for
wiring.
[Crimp-style connector housing: 179228-2, Crimp-style
connector contact: 179227-4]
• The above connectors are not sold by OMRON.
Contact the offices mentioned in the right for more information
on the connectors.
2
Tyco Electronics Corporation, TE Connectivity Ltd.
■For products and technical support, contact the
Web: http://www.te.com/support-center/
D2X
Detection Switch
㧰
2
X
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY
Contact: www.omron.com/ecb
Cat. No. B094-E1-04
0812(0207)(O)
3