13203CC TM Eliminates management of calibration data Interchangeable, Rugged Uniaxial Accelerometer ±1 g to ±15 g Preliminary Technical Data* Features and Benefits IdentiCal™ Interchangeable Sensor IdentiCal™ sensors eliminate the management of calibration data and allow convenient interchangeability of individual sensors. With standardized sensitivity and offset, there is no need to enter new parameters for each unit. 13203CC is perfect for high volume use. TM Rugged for Harsh Environments The 13203CC is robust to perform well in harsh environments. The 6061-T6 case with electroless nickel finish plus a Teflon cable with a shield bonded to the case provide improved resistance to EMI, lightning, or other disturbances. The enclosure is rated IP65. The unit has resilient power and will survive 5000 g powered and unpowered. The 13203CC has a 22 AWG cable with only four wires to connect. High Accuracy and Linearity over Wide Temperature Range The output of the 13203CC is directly proportional to the acceleration of its axis. The DC-coupled output is fully scaled, referenced, and temperature compensated. When used in demanding temperature environments, the 13203CC is one of the most accurate accelerometers available. Small Size Complete conditioned accelerometer package in less than a cubic inch; it may be easily mounted for any axis orientation. uilt-In Power Supply Regulation B Unregulated DC power from +8.5 to +36 Volts is all that is required to measure acceleration. The 13203CC is operational with transients of +80 V for 550 ms compatible with MIL-STD-704A. Earth Friendly Design Lead-free design makes the 13203CC environmentally safe while Measurement Specialties’ assembly process ensures reliable functionality. Fully potted electronics eliminates the possibility of tin whiskers-related failures. Three Year Warranty These Measurement Specialties’ accelerometers are covered by a three year return to factory warranty. Extended warranties are available. 13203CC Uniaxial Analog Accelerometer precisionsensors.meas-spec.com Precisely Measure Rates Over Temperature The Measurement Specialties 13203CC is an interchangeable and rugged uniaxial accelerometer capable of accurately measuring acceleration under demanding environmental conditions. A tough, compact housing holds potted electronics and a shielded heavyweight cable. Its cubical form allows mounting with the sensing axis oriented in any direction. The 13203CC provides enhanced accuracy and durability features to meet the challenges of your application. In addition to its robust construction, increased precision is achieved through improved offset and gain compensation. Each axial sensor has been tested over the -40 to +85°C temperature range and has a nominal full scale output swing of ±2 Volts. Sensors are available in various fixed sensitivities, each with a 2.500 V offset. The 13203CC can also be ordered with different bandwidths and wiring configurations. 2236 N. Cleveland-Massillon Road Akron OH 44333 PH : 330-659-3312 7/18/2013 www.meas-spec.com Specifications for 13203CC - improved specifications available upon request Ta = Tmin to Tmax; 8.5 ≤ Vs ≤ 36 V; Acceleration = 0 g unless otherwise noted; within one year of calibration. Parameter Range & Sensitivity* at 25°C Option R015 Option R010 Option R006 Option R005 Option R004 Option R003 Option R002 Option R001 Min Typical Max Units 0.130 0.200 0.330 0.400 0.500 0.660 1.000 2.000 V/g V/g V/g V/g V/g V/g V/g V/g % FSR Sensitivity Drift 25°C to Tmin or Tmax ±1.0 Offset at 25°C Zero g Bias Level 2.500 V Offset Drift 25°C to Tmin or Tmax ±1.0 % FSR Alignment Deviation from Ideal Axes ±1.5 degrees Transverse Sensitivity 0.25 % Nonlinearity 0.065 Frequency Response 0 Noise Density Outputs Output Voltage Swing Power Supply (Vs) Input Voltage Limits Input Voltage - Operating Input Current Rejection Ratio -80 +8.5 12 >120 +80 +36 Temperature Range (Ta) +85 Mass Shock Survival Conditions/Notes Must specify via Option Rnnn, see Ordering Info Maximum error ±0.75% of nominal at 25°C. Max error ±50 mg of nominal at 25°C Inherent sensor error, excluding misalignment % FSR 800 Best fit straight line Hz 100 Upper cutoff per Option Bnnn, -3dB pt ±10% µg/√Hz 0.25 4.75 -40 Ta = 25°C Measuring equipment >10 MΩ recommended Iout = 1 mA, Capacitive load <1000 pF V V V mA dB -80V continuous, >38 V if ≤550 ms, duty <1% No load, quiescent DC °C 38 grams -5000 +5000 g Any axis for 0.5 ms, powered or unpowered Data subject to change without notice *IdentiCal sensors are interchangeable, any with same range have same value Mechanical 1 1 1 Option D Male D-Shell Connector 1.073 [27,30] 0.295 [7,50] 3 mm x 0,5 mm Thread 3,5 mm [0.138] Deep 0.295 [7,50] (6) Mounting Holes on 3 sides Pin Signal Wire 0.945 [24,00] 0.354 [9,0] Dimensions in inches [mm], identical for each view where applicable. 22 AWG Cable 1 6061-T6 aluminum case with electroless nickel finish plus integrated cable with shield bonded at the case Shown with 34170B mounting adapter (sold separately) 13203CC Uniaxial Analog Accelerometer precisionsensors.meas-spec.com 1 A1+ Green 2 Signal - Blue 3 Not Used 4 Not Used 5 Not Used 6 Not Used 7 Not Used 8 +Vs Orange 9 Gnd White Ordering Information 13203CC - R015 - B800 - T2.5B 0.945 0.354 [24,00] [9,0] Third angle Connections Instrument 13203CC Range R015 : R010 : R006 : R005 : R004 : R003 : R002 : R001 : ±15 g ±10 g ±6 g ±5 g ±4 g ±3 g ±2 g ±1 g Bandwidth B800 : 0 to B380 : 0 to B208 : 0 to B142 : 0 to B094 : 0 to B066 : 0 to B031 : 0 to B6.6 : 0 to Connector A : None, tinned leads B : None, DIN 46228 terminal tubes C : 6-pin M12 connector D : 9-pin DB9M connector 800 Hz 380 Hz 208 Hz 142 Hz 94 Hz 66 Hz 31 Hz 6.6 Hz 2236 N. Cleveland-Massillon Road Akron OH 44333 PH : 330-659-3312 Termination Length T2.5 : 2.5 ft. cable T004 : 4 ft. cable Tnnn : Custom length, nnn ft. (call SI) 7/18/2013 www.meas-spec.com