IDT IDT74CBTLV16214

IDT74CBTLV16214
LOW-VOLTAGE 12-BIT 3:1 MUX / DEMUX BUS SWITCH
INDUSTRIAL TEMPERATURE RANGE
LOW-VOLTAGE 12-BIT 3:1
MUX / DEMUX BUS SWITCH
FEATURES:
IDT74CBTLV16214
DESCRIPTION:
5Ω
Ω A/B bi-directional switch
Isolation Under Power-Off Conditions
Over-voltage tolerant
Latch-up performance exceeds 100mA
VCC = 2.3V - 3.6V, normal range
ESD >2000V per MIL-STD-883, Method 3015; >200V using
machine model (C = 200pF, R = 0)
• Available in SSOP, TSSOP, and TVSOP packages
•
•
•
•
•
•
The CBTLV16214 provides a set of 12 high-speed buses switching
between three separate ports. The low ON resistance allows inputs to be
connected to outputs without adding propagation delay. The CBTLV16214
operates as a 12-bit bus select through the data select (S0-S2) terminals.
APPLICATIONS:
• Muxing and demuxing
• 3.3V High Speed Bus Switching and Bus Isolation
• Hot-swapping, hot-docking
FUNCTIONAL BLOCK DIAGRAM
1A
2
SIMPLIFIED SCHEMATIC, EACH
SWITCH
54
SW
53
SW
SW
3
1B1
1B2
1B3
A
12A
27
30
SW
29
SW
SW
28
B
12B1
12B2
12B3
FLOW CONTROL
CIRCUITRY
S0
S1
S2
1
56
55
The IDT logo is a registered trademark of Integrated Device Technology, Inc.
INDUSTRIAL TEMPERATURE RANGE
AUGUST 2002
1
c
2002 Integrated Device Technology, Inc.
DSC-5890/5
IDT74CBTLV16214
LOW-VOLTAGE 12-BIT 3:1 MUX / DEMUX BUS SWITCH
INDUSTRIAL TEMPERATURE RANGE
PIN CONFIGURATION
ABSOLUTE MAXIMUM RATINGS(1)
Symbol
S0
1
56
S1
VCC
1A
2
55
S2
VI
1B3
3
54
1B1
2A
4
53
1B2
2B3
5
52
2B1
Description
IIK
Max.
Unit
Supply Voltage Range
–0.5 to 4.6
V
Input Voltage Range
–0.5 to 4.6
V
Continuous Channel Current
128
mA
Input Clamp Current, VI/O < 0
–50
mA
–65 to +150
°C
Storage Temperature Range
TSTG
NOTE:
1. Stresses greater than those listed under ABSOLUTE MAXIMUM RATINGS may cause
permanent damage to the device. This is a stress rating only and functional operation
of the device at these or any other conditions above those indicated in the operational
sections of this specification is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect reliability.
3A
6
51
2B2
3B3
7
50
3B1
GND
8
49
GND
4A
9
48
3B2
4B3
10
47
4B1
5A
11
46
4B2
5B3
12
45
5B1
6A
13
44
5B2
6B3
14
43
6B1
7A
15
42
6B2
xA
Port A Inputs or Outputs
7B3
16
41
7B1
xBx
Port B Inputs or Outputs
VCC
17
40
7B2
8A
18
39
8B1
GND
19
38
GND
8B3
20
37
8B2
9A
21
36
9B1
S2
S1
9B3
22
35
9B2
L
L
L
Z
Disconnect
L
L
H
B1
A Port = B1 Port
L
H
L
B2
A Port = B2 Port
L
H
H
Z
Disconnect
H
L
L
Z
Disconnect
H
L
H
B3
A Port = B3 Port
H
H
L
B1
A Port = B1 Port
H
H
H
B2
A Port = B2 Port
10A
23
34
10B1
10B3
24
33
10B2
11A
25
32
11B1
11B3
26
31
11B2
12A
27
30
12B1
12B3
28
29
12B2
PIN DESCRIPTION
Pin Names
Description
Sx
Data Select Inputs
FUNCTION TABLE(1)
Inputs
Inputs/Outputs
S0
A
Operation
NOTE:
1. H = HIGH Voltage Level
L = LOW Voltage Level
Z = High-Impedance
SSOP/ TSSOP/ TVSOP
TOP VIEW
OPERATING CHARACTERISTICS(1)
Symbol
Parameter
VCC
Supply Voltage
VIH
High-Level Control Input Voltage
VIL
Low-Level Control Input Voltage
TA
Operating Free-Air Temperature
Test Conditions
Min.
Max.
Unit
2.3
3.6
V
VCC = 2.3V to 2.7V
1.7
—
V
VCC = 2.7V to 3.6V
2
—
VCC = 2.3V to 2.7V
—
0.7
VCC = 2.7V to 3.6V
NOTE:
1. All unused control inputs of the device must be held at VCC or GND to ensure proper device operation.
2
—
0.8
–40
+85
V
°C
IDT74CBTLV16214
LOW-VOLTAGE 12-BIT 3:1 MUX / DEMUX BUS SWITCH
INDUSTRIAL TEMPERATURE RANGE
DC ELECTRICAL CHARACTERISTICS OVER OPERATING RANGE
Following Conditions Apply Unless Otherwise Specified:
Operating Condition: TA = –40°C to +85°C
Symbol
Typ.(1)
Max.
—
—
–1.2
V
—
—
±1
µA
—
—
5
µA
VCC = 0V, VI or VO = 0V or 3.6V
—
—
10
µA
VCC = 3.6V, IO = 0, VI = VCC or GND
—
—
10
µA
Parameter
Test Conditions
Control Inputs, Data I/O
VCC = 3V, II = –18mA
Control Inputs
VCC = 3.6V, VI = VCC or GND
Data I/O
VCC = 3.6V, VO = 0V or 3.6V switch disabled
IOFF
ICC
VIK
II
I OZ
Min.
Unit
∆ICC(2)
Control Inputs
VCC = 3.6V, one input at 3V, other inputs at VCC or GND
—
—
300
µA
CI
Control Inputs
VI = 3V or 0
—
4
—
pF
A
VO = 3V or 0 (switch off)
—
20
—
pF
CIO(OFF)
B
Max. at VCC = 2.3V
—
7.5
—
VI = 0
IO = 64mA
—
5
8
IO = 24mA
—
5
8
VI = 1.7V
IO = 15mA
—
27
40
VI = 0
IO = 64mA
—
5
7
IO = 24mA
—
5
7
VI = 2.4V
IO = 15mA
—
10
15
Typ. at VCC = 2.5V
RON(3)
VCC = 3V
Ω
NOTES:
1. Typical values are at 3.3V, +25°C ambient.
2. The increase in supply current is attributable to each input that is at the specified voltage level rather than VCC or GND.
3. This is measured by the voltage drop between the A and B terminals at the indicated current through the switch.
SWITCHING CHARACTERISTICS
VCC = 2.5V ± 0.2V
Symbol
tPD(1)
Parameter
Propagation Delay
VCC = 3.3V ± 0.3V
Min.
Max.
Min.
Max.
Unit
—
0.15
—
0.25
ns
1
6.5
1
6
ns
1
6.5
1
6
ns
1
7
1
6.5
ns
A to B or B to A
tPD
Propagation Delay
S to A or B
tEN
Output Enable Time
S to A or B
tDIS
Output Disable time
S to A or B
NOTE:
1. The propagation delay is the calculated RC time constant of the typical on-state resistance of the switch and the specified load capacitance when driven by an ideal voltage source
(zero output impededance).
3
IDT74CBTLV16214
LOW-VOLTAGE 12-BIT 3:1 MUX / DEMUX BUS SWITCH
INDUSTRIAL TEMPERATURE RANGE
TEST CIRCUITS AND WAVEFORMS
TEST CONDITIONS
Symbol
VCC(1)= 3.3V±0.3V
VCC(2)= 2.5V±0.2V
Unit
VLOAD
6
2 x Vcc
V
VIH
3
Vcc
V
VT
1.5
Vcc / 2
V
VLZ
300
150
mV
VHZ
300
150
mV
CL
50
30
pF
SAME PHASE
INPUT TRANSITION
tPLH
tPHL
tPLH
tPHL
OUTPUT
VIH
VT
0V
VOH
VT
VOL
VIH
VT
0V
OPPOSITE PHASE
INPUT TRANSITION
Propagation Delay
VLOAD
VCC
500Ω
Pulse(1, 2)
Generator
VIN
CONTROL
INPUT
GND
tPZL
VOUT
D.U.T.
RT
DISABLE
ENABLE
Open
OUTPUT
SWITCH
NORMALLY
CLOSED
LOW
tPZH
OUTPUT SWITCH
NORMALLY
OPEN
HIGH
500Ω
CL
Test Circuits for All Outputs
SWITCH POSITION
Switch
VLOAD
tPHZ/tPZH
GND
tPD
Open
tPHZ
VT
0V
Enable and Disable Times
NOTES:
1. Pulse Generator for All Pulses: Rate ≤ 10MHz; tF ≤ 2.5ns; tR ≤ 2.5ns.
2. Pulse Generator for All Pulses: Rate ≤ 10MHz; tF ≤ 2ns; tR ≤ 2ns.
Test
VLOAD/2
VT
VLOAD/2
VOL + VLZ
VOL
VOH
VOH -VHZ
0V
NOTE:
1. Diagram shown for input Control Enable-LOW and input Control Disable-HIGH.
DEFINITIONS:
CL = Load capacitance: includes jig and probe capacitance.
RT = Termination resistance: should be equal to ZOUT of the Pulse Generator.
tPLZ/tPZL
tPLZ
VIH
VT
0V
4
IDT74CBTLV16214
LOW-VOLTAGE 12-BIT 3:1 MUX / DEMUX BUS SWITCH
INDUSTRIAL TEMPERATURE RANGE
ORDERING INFORMATION
XXX
XX
CBTLV
IDT
XX
Device Type Package
Temp. Range
CORPORATE HEADQUARTERS
2975 Stender Way
Santa Clara, CA 95054
PV
PA
PF
Shrink Small Outline Package
Thin Shrink Small Outline Package
Thin Very Small Outline Package
16214
Low-Voltage 12-Bit 3:1 Mux / Demux Bus Switch
74
–40°C to +85°C
for SALES:
800-345-7015 or 408-727-6116
fax: 408-492-8674
www.idt.com
5
for Tech Support:
[email protected]
(408) 654-6459