Downloads for Chassis Mount Leaded World Series™ Power Transformers (VPL24-2000)

P OWER TRANS FOR MER
Chassis Mount : International Series
VPL24-2000
Electrical Specifications (@25C)
1. Maximum Power: 50.0VA
2. Input Voltage – Series: 230VAC @ 50/60Hz, Parallel: 115VAC@ 50/60Hz
3. Output Voltage – Series: 24.0V CT@ 2.083A, Parallel: 12.0V @ 4.116A
4. Voltage Regulation: 20% TYP @ full load to no load
5. Hipot: 3500VAC between primary to secondary and windings to core.
Dual winding construction with an insulated shroud, both made of a high temperature
material that exceeds UL flammability requirements. Shrouds are provided over the
connections of the leads to the windings on both primary and secondary coils. Devices are
designed with a minimum of 6mm creepage distance between the primary and secondary
and are manufactured with a Class B (130°C) insulation system.
BRN
BLU
BLK
WHT
Construction:
E
A
Agency Files:
VIO
RED
GRY
YEL
TUV Certificate No.: R72103639, EN60950, Information Technology
B
Dimensions:
Units: In inches
A
B
C
D
E
F
2.562
4.00
2.250
3.562
8.00
0.187
D
C
Weight: 2.3 lbs.
F
Connections1:
Input: Series – BLK to BLU, Jumper WHT to BRN
Parallel – BLK to BLU, Jumper BLK to BRN and WHT to BLU
BLK
RED
WHT
BRN
YEL
VIO
BLU
GRY
Output: Series – RED to GRY, Jumper YEL to VIO
Parallel – RED to GRY, Jumper RED to VIO and YEL to GRY
RoHS Compliance: As of manufacturing date February 2005, all standard products meet the
requirements of 2011/65/EU, known as the RoHS initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’
website for the most current version.
1
Primary and secondary windings are designed to be connected in series or parallel. Winding are not
intended to be used independently.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
SCHEMATIC