Product Catalogue 2015 < C Precision Current Measurements PrecisionCurrent Transducers < CT-BOX ! 2 DigitalCurrentTransducerBoxfortheHighestAccuracyCurrentMeasurements 4 CT-PCBSeries 13A,26Aand52AFull-ScalePrecisionCurrentTransducersforPCBMounJng CT-100/CT-150 6 100Aand150AFull-ScalePrecisionCurrentTransducersforRack/PanelandPCBMounJng < 8 CT-200/CT-300/CT-400 INDEX -SelecJonGuide 9 200A,300Aand400AFull-ScalePrecisionCurrentTransducersforRack/PanelMounJng 11 CT-600/CT-1000 600Aand1000AFull-ScalePrecisionCurrentTransducersforRack/PanelMounJng PS1215 13 Low-NoiseBipolarPowerSupplyforCurrentTransducers C 15 FrequencyResponse MaximumCurrentRaJngs C ProductOverview CT-BOX DigitalCurrentTransducerBox fortheHighestAccuracyCurrentMeasurements PrecisionCurrent Transducers < ! CT-BOX ●Preciseandaccuratecurrentmeasuringsystemincludescurrenttransducerandmeasuring unitinordertoobtainbest-in-classperformances. ●InternalcalibraJonandthermalstabilizaJontoobtainexcellentstabilityofcurrent measurements. ●Data-loggerandoscilloscopemodesofoperaJon FEATURES •DigitalInterface -Ethernet -USB -RS-232 •<1ppm/KTemperatureCoefficient •<0.005%Full-ScaleAccuracy(with High-AccuracyCalibraHonOpHon) •ConfigurableRecorderonmicroSD-Flash •TriggerInput/OutputandAlarmOutput •ExternalTemperatureSensors •AnalogMonitor •LocalDisplayforCurrentReadings •DesktoporRackMounHngin1U •IntegratedFan-lessAC/DCPowerSupply •DedicatedSoewareApplicaHon APPLICATIONS •Test&MeasurementSetups •SensingElementinCalibraHonSystems •PowerSupplies •BiomedicalDevices TheCT-BOXisastand-alonesystem designedtomeasurewiththehighest accuracyandprecisionDCandAC currents,providingthereadingsin differentdigitalformats. TheCT-BOXsystemisdevelopedtobe usedwiththe0-FLUCScurrentoutput DCCTsallowingmeasurementsof currentsuptokA. Thesystemintegratesaburdenresistor andacondiHoningnetworkfeedinga 24-bittemperaturestabilizedADCin ordertohave<1ppm/Ktemperature dependence.ThedigitalsecHon interfacedtotheADCperformsa calibratedmeasurementinorderto eliminatethenon-idealbehaviorthus providinga0.005%Full-scalecurrent valueaccuracy(opHonal).TheADC samplingfrequencycanbeconfigured upto100kHzallowingtoacquirehigh frequencycomponentsandfastcurrent transients. Currentreadingscanbetriggeredin differentmodes: •byanexternalLVTTLorTTLsignal; •byaremotecommandsenttothe digitalinterface; •internally,se\ngthesamplingperiod andtheacquisiHonwindow. TheHme-stamp,thecurrentreadingsand theexternaltemperaturevaluesare storedinamicroSDFlashmemory allowinglong-termacquisiHons. ThemicroSDmemorycanbeeitherread viaEthernet,USBorRS-232interfacesor removedfromthesystemandtransferred tootherdevicesinordertodownloadits content. Atemperatureprobecanbepluggedon thebackofthesystemifneededinorder toalsoreadandstoreexternal temperaturevalues. Alocaldisplayshowingcurrentreadings aswellasotherse\ngs–e.g.IPaddress, modeofoperaHon–ispresent. Aconfigurablealarmoutputcanbeused tosignaltoanexternaldeviceifapre-set currentthresholdhasbeenexceeded. C AboutUs CAENELSisaleadingcompanyinthedesign AnintegratedfuncHonallowsto compensateformeasurementsetup offsetcurrents. CT-BOXdirectlytotheACmains. Theextremelycompactdesign Theunitintegratesalow-noisemixed AC/DCpowersupplytoconnectthe (1U–9”)allowsusingtheinstrument asbenchmarkortoinstallthe systemsina1U-19”rack. ofpowersuppliesandstate-of-the-art completeelectronicsystemsforthePhysics researchworld,havingitsmainfocuson dedicatedsoluJonsfortheparJcle acceleratorcommunityandhigh-end TechnicalSpecificaJons ACLineInput industrialapplicaJons. MaximumPowerConsumpHon CurrentAccuracy 25W <0.01%(standard) <0.005%(High-AccuracyopHon) • PowerSupplySystems • PrecisionCurrentMeasurements • BeamlineElectronicInstrumentaJon ThermalCoefficient(typ.) • FMC&MTCA.4–MicroTCAforPhysics CurrentRangesAvailable[A] CurrentResoluHon 24-bit SamplingFrequency 0.1Hz–100kHz <1ppm/K 100,150,200,300,400,600,1000 CurrentReadings 7½digits NumberofMemoryReadings CAENELSd.o.o. CT-BOX 90-260V(AC),46-440Hz dependingonmicroSDcardcapacity PowerOK,DCCTconnected,Status, SDreading/wriHng,AcquisiHonrunning Kraškaulica,2 6210–Sežana Slovenija LEDIndicators Phone+386(0)57313585 Fax+386(0)57313587 TemperatureProbeAccuracy TemperatureProbeResoluHon 0.1°C ±0.5°C TemperatureAccuracy 0.05% [email protected] www.caenels.com www.caenels.com DigitalInterfaces Ethernet10/100MbpsTCP-IP USB2.0 RS-232 AnalogMonitor ±10V(LEMOconnector) TriggerInputs DigitalInterface(soe-trigger) TTL5V–LVTTLcompaHble AlarmOutput TTL5V SolidStateRelay MechanicalDimensions(L×W×H) OperaHngTemperature 180×220×41mm 0…40°C CT-BOX alsofor1U–19’’installa0on < Current Transducers OrderingOpJons WCTBOX100XAA CT-BOX-100 100ACurrentTransducerDigitalBoxwithLocalDisplayandEthernet,USB,RS-232CommunicaHonInterfaces WCTBOX150XAA CT-BOX-150 200ACurrentTransducerDigitalBoxwithLocalDisplayandEthernet,USB,RS-232CommunicaHonInterfaces WCTBOX200XAA CT-BOX-200 200ACurrentTransducerDigitalBoxwithLocalDisplayandEthernet,USB,RS-232CommunicaHonInterfaces WCTBOX300XAA CT-BOX-300 300ACurrentTransducerDigitalBoxwithLocalDisplayandEthernet,USB,RS-232CommunicaHonInterfaces WCTBOX400XAA CT-BOX-400 400ACurrentTransducerDigitalBoxwithLocalDisplayandEthernet,USB,RS-232CommunicaHonInterfaces WCTBOX600XAA CT-BOX-600 600ACurrentTransducerDigitalBoxwithLocalDisplayandEthernet,USB,RS-232CommunicaHonInterfaces WCTBOX1000XA CT-BOX-1000 1000ACurrentTransducerDigitalBoxwithLocalDisplayandEthernet,USB,RS-232CommunicaHonInterfaces WCTBOXMBXAAA CT-BOX-MB CT-BOXmounHngbracketsfor1U–19”cabinetinstallaHon WCTBOX1YXAAA CT-BOX-YC CT-BOXIn-HouseYearlyCalibraHonService(<0.01%accuracy) WCTBOXSICLXA CT-BOX-HAC CT-BOXHigh-AccuracyCalibraHonService(<0.005%accuracy) C Copyright©CAENELSd.o.o.–2015 Allrightsreserved.InformaHoninthispublicaHonsupersedesallearlierversions. SpecificaHonssubjecttochangewithoutnoHce. Rev1.0–PrintedinOctober2015. C < ProductOverview CT-13 CT-26 CT-52 PrecisionCurrent Transducers ! Currentor Voltage Output CT-PCBSeries ●Closed-loopcurrenttransformertechnologyallowsaccuratemonitoringofDCandAC bipolarcurrentsupto±52AwithasmallPCB-mountdevice. ●GalvanicisolaJonbetweenprimaryandsecondaryconductorforsimplecurrentsensingat differentpotenJal. ●Standardcurrentoutputandvoltageoutput(“V”-version)available. FEATURES •MonitoringofDCandACcurrents •ExcellentLinearity •Closed-loopdetecHon •Galvanicallyisolatedfromprimary •LowTemperatureDrie •Current-outputorVoltage-output versions •WideBandwidth •HighAccuracy •UL94V-0flammabilitygrade •LEDindicatescorrectoperaHon •PCB-mountversions APPLICATIONS •PowerSupplies •SensingElementinCalibraHonSystems •BiomedicalDevices •Test&MeasurementSetups The0-FLUCS(0-FLUxCurrentSensor) familyisbasedonaclosedloop andlow-noiseamplifierareembedded intheCT-13V,CT-26VandCT-52V). technologythatallowsaccurateand precisemonitoringofDCandAC currentswithhighbandwidth.Themetal MaincharacterisHcsofthe0-FLUCS currenttransformersarenegligible casingguaranteeshighernoiseimmunity andreducesundesirednoisepick-up fromexternalsources. temperaturecoefficientonthe secondaryoutputcurrent,excellent linearityandextremelylownoise. ThetransducersCT-13,CT-26andCT-52 arePCB-mountdevicesratedat DCcurrenttransformersrepresentthe idealreplacementforsystemswhere maximumcurrentsof13A,26Aand52A withprimarytosecondaryraHoof1:250, 1:500and1:1000respecHvely. Hall-effectsensorsareusedascurrent sensingelementsandbe|er performancesareneeded. GalvanicisolaHonbetweentheprimary andthesecondarycircuitsallowsto measurecurrentsatadifferentpotenHal Thecompactmechanicaldimensionsof thistransducerseriesanditslimited andsimplifiesinterfacingwhenusing theO-FLUCSasthefeedbackelement ofcurrentregulatedpowersupplies. weightallowforeasymounHngon printedcircuitboardswithaThrough Hole(TH)topology.AplasHccoveris OutputfromtheCT-PCBsensorscanbe placedonthebo|omsideofthedevice toallowforeasiermounHngonthePCB. chosenbetweentwodifferent versions:standardsecondarycurrent MainapplicaHonsforthesecurrent transducersarepreciseandstable outputorbufferedvoltageoutput(low temperaturecoefficientshuntresistor regulatedpowersuppliesandpower inverters. C AboutUs CAENELSisaleadingcompanyinthedesign DuetotheexcellentcharacterisHcs,the CTPCBtransducerscanbeused inavarietyofcalibraHon,acceptance tesHngandqualitycontrolapplicaHons inindustrial,powergeneraHonand Commerciallyavailableversionsof theCT-13,CT-26andCT-52with theirrespecHve“V”voltage-output versionsCT-13V,CT-26VandCT-52V. automoHvefields. ofpowersuppliesandstate-of-the-art completeelectronicsystemsforthePhysics researchworld,havingitsmainfocuson TechnicalSpecificaJons dedicatedsoluJonsfortheparJcle CurrentTransformRaHo-N industrialapplicaJons. MaximumDCPrimaryCurrent-IP(DC) MaximumRMSPrimaryCurrent-IP(RMS) 9.2A acceleratorcommunityandhigh-end • PowerSupplySystems • PrecisionCurrentMeasurements • BeamlineElectronicInstrumentaJon • FMC&MTCA.4–MicroTCAforPhysics CT-13 CT-26 CT-52 1:250 1:500 1:1000 ±13A ±26A ±52A 18.4A 36.8A CurrentPolarity Bipolar MaximumDCSecondaryCurrent-IS(DC) ±52mA MaximumRMSSecondaryCurrent-IS(RMS) 37mA SmallSignalBandwidth–typ. 500kHz SmallSignalBandwidth–“V”-version–typ. >200kHz <1ppm(@200Hz) <10ppm(@50kHz) Noise(RMS)–typ. CAENELSd.o.o. Kraškaulica,2 6210–Sežana Slovenija Phone+386(0)57313585 Fax+386(0)57313587 [email protected] www.caenels.com OutputVoltage(“V”-version)-VOUT OutputVoltageRaHo(“V”version)–VOUT/IP(DC) ±10V 0.8V/A 0.4V/A MaximumOutputCurrent–“V”-version ±15mA <0.5ppm/K <2ppm/K(“V”-version) TemperatureCoefficient–TC(typ.) ProtecHonSignal Yes–OKStatus SupplyVoltage(±6%) ±15V ConnecHons 16-pinthrough-holePCBmounHng Mechanical(Outer)Dimensions www.caenels.com 0.2V/A 66×68×48mm PrimaryConductor Internal MaximumWeight 300g CT-PCBVoltageOutput–“V”Version <! DC+20-kHzsine-waveprimarycurrent–i.e.I P[A]–andoutput voltageofaCT-13Vversion–i.e.VO[V] 0-FLUCS Closed–Loop Technology The CT-PCB current transducer series is based on the CAEN ELS 0-FLUCS Closed-Loop Technology. OrderingOpJons C WCT13XAAAAAA CT-13 WCT26XAAAAAA CT-26 13APrimaryCurrentO-FLUCS,PCB-MounHng 26APrimaryCurrentO-FLUCS,PCB-MounHng WCT52VXAAAAA CT-52 52APrimaryCurrentO-FLUCS,PCB-MounHng, WCT13VXAAAAA CT-13V 13APrimaryCurrentO-FLUCS,PCB-MounHng,Voltage-Output WCT26VXAAAAA CT-26V 26APrimaryCurrentO-FLUCS,PCB-MounHng,Voltage-Output WCT52VXAAAAA CT-52V 52APrimaryCurrentO-FLUCS,PCB-MounHng,Voltage-Output Copyright©CAENELSd.o.o.–2015 Allrightsreserved.InformaHoninthispublicaHonsupersedesallearlierversions. SpecificaHonssubjecttochangewithoutnoHce. Rev1.0–PrintedinOctober2015. C < ProductOverview CT-100 CT-150 PrecisionCurrent Transducers Currentor Voltage Output ! CT-100/CT-150 ●Closed-loopcurrenttransformertechnologyallowsaccuratemonitoringofDCandAC bipolarcurrentsupto±100A(CT-100)orupto±150A(CT-150). ●GalvanicisolaJonbetweenprimaryandsecondaryconductorforsimplecurrentsensingat differentpotenJal. ●Standardcurrentoutputandvoltageoutput(“V”-version)available. FEATURES •MonitoringofDCandACcurrents •ExcellentLinearity •Closed-loopdetecHon •Galvanicallyisolatedfromprimary •LowTemperatureDrie •Current-outputorVoltage-output versions •WideBandwidth •HighAccuracy •UL94V-0flammabilitygrade •LEDindicatescorrectoperaHon •DB-9ConnectororPCB-mountversions APPLICATIONS •PowerSupplies •SensingElementinCalibraHonSystems •BiomedicalDevices •NuclearMagneHcResonance(NMR) •Test&MeasurementSetups The0-FLUCS(0-FLUxCurrentSensor) familyisbasedonaclosedloop technologythatallowsaccurateand precisemonitoringofDCandAC currentswithhighbandwidth. TheCT-100/CT-150transducersare ratedatamaximumbipolarprimary currentof100A/150Awitha transformaHonraHoof1:1000/1:1500. GalvanicisolaHonbetweentheprimary andthesecondarycircuitsallowsto measurecurrentsatadifferentpotenHal andsimplifiesinterfacingwhenusing the0-FLUCSasthefeedbackelement ofcurrentregulatedpowersupplies. Outputfromthe0-FLUCStransducers canbechosenbetweentwodifferent versions:secondarycurrentoutput orbufferedvoltageoutput(low temperaturecoefficientshuntresistor andlow-noiseamplifierareembedded inthedevice). AlsoconnecHontypecanbechosen betweenthe“C”opHon–amaleDB-9 Connector–andthe“P”opHon–7-pin through-holeforPCBmounHng. MaincharacterisHcsofthe0-FLUCS currenttransformersarenegligible temperaturecoefficientonthe secondaryoutputcurrent,excellent linearityandextremelylownoise. DCcurrenttransformersrepresentsthe idealreplacementforsystemswhere Hall-effectsensorsareusedascurrent sensingelementsandbe|er performancesareneeded. AllCT-100/CT-150devicesalsohave differentmounHngholesinordertobe easilyinstalledindifferentconfiguraHons. Bothself-threadingscrewsandnormal Onescanbeused. MainapplicaHonfieldsforthesecurrent transducersarepreciseandextremely stableregulatedpowersuppliesand powerinverters. C DuetotheexcellentcharacterisHcs, the0-FLUCStransducerscanbeused Commerciallyavailableversionsof inavarietyofcalibraHon,acceptance areDB-9connector“C”and7-pin tesHngandqualitycontrolapplicaHons striptype“P”withtheirrespecHve AboutUs inindustrial,powergeneraHonand voltage-outputversions“V”. CAENELSisaleadingcompanyinthedesign automoHvefields. ofpowersuppliesandstate-of-the-art completeelectronicsystemsforthePhysics theCT-100/CT-150currentsensors researchworld,havingitsmainfocuson TechnicalSpecificaJons dedicatedsoluJonsfortheparJcle CurrentTransformRaHo–N 1:1000 1:1500 MaximumDCPrimaryCurrent-IP(DC) ±100A ±150A acceleratorcommunityandhigh-end industrialapplicaJons. CT-100 MaximumRMSPrimaryCurrent-IP(RMS) 71A 106A CurrentPolarity Bipolar • PowerSupplySystems MaximumDCSecondaryCurrent-IS(DC) • PrecisionCurrentMeasurements MaximumRMSSecondaryCurrent-IS(RMS) • BeamlineElectronicInstrumentaJon • FMC&MTCA.4–MicroTCAforPhysics ±100mA 71mA >500kHz >200kHz(“V”-version) SmallSignalBandwidth(±3dB)-BW <0.5ppm(@200Hz) <5ppm(@50kHz) Noise(RMS)–typ. ExternalShuntResistance(currentoutputonly)-RS CAENELSd.o.o. CT-150 <1.5ppm(@200Hz) <8ppm(@50kHz) 0Ω–40Ω OutputVoltage(“V”-version)-VOUT ±10V Kraškaulica,2 6210–Sežana Slovenija OutputVoltageRaHo(“V”version)–VOUT/IP(DC) Phone+386(0)57313585 Fax+386(0)57313587 TemperatureCoefficient–TC(typ.) <0.5ppm/K <2ppm/K(“V”-version) Linearity <5ppm <15ppm(“V”-version) [email protected] www.caenels.com InducHonintoPrimary(typ.) 0.1V/A MaximumOutputCurrent–“V”-version 35µV(RMS) ProtecHonSignal Yes-PrimaryOver-Current SupplyVoltage(±6%) www.caenels.com (1/15)V/A ±15mA ±15V DB-9Connector(“C”) or 7-pintype(“P”) ConnecHons Mechanical(Outer)Dimensions 45×57×75mm PrimaryConductorHoleDiameter–Ø 16mm OperaHngTemperatueRange 0…+50°C MaximumWeight 250g PS1215I–PS1215V Low-NoisePowerSupplies forcurrenttransducers <! CT-100/CT-150 7-pinstripconnectorforPCB 0-FLUCS Closed–Loop Technology The CT-100 and CT-150 current transducer series is based on the CAEN ELS 0-FLUCS Closed-Loop Technology. C OrderingOpJons WCT100CXAAAA CT-100-C 100APrimaryCurrent0-FLUCS,DB-9connector WCT100PXAAAA CT-100-P 100APrimaryCurrent0-FLUCS,7-pintypeconnecHons WCT100VCXAAA CT-100V-C 100APrimaryCurrent0-FLUCS,DB-9connector,Voltage-Output WCT100VPXAAA CT-100V-P 100APrimaryCurrent0-FLUCS,7-pintypeconnecHons,Voltage-Output WCT150CXAAAA CT-150-C 150APrimaryCurrent0-FLUCS,DB-9connector WCT150PXAAAA CT-150-P 150APrimaryCurrent0-FLUCS,7-pintypeconnecHons WCT150VCXAAA CT-150V-C 150APrimaryCurrent0-FLUCS,DB-9connector,Voltage-Output WCT150VPXAAA CT-150V-P 150APrimaryCurrent0-FLUCS,7-pintypeconnecHons,Voltage-Output Copyright©CAENELSd.o.o.–2015 Allrightsreserved.InformaHoninthispublicaHonsupersedesallearlierversions. SpecificaHonssubjecttochangewithoutnoHce. Rev1.0–PrintedinOctober2015. ! < Thefollowingtablesummarizesdataandcharacteris6csofthe<currenttransducerstandardmodels: Model Maximum DC Primary Current Current Transformer Ratio - N ±13 A 1:250 CT-13 Bandwidth (3 dB) – BW >500 kHz CT-13V >200 kHz CT-26 >500 kHz ±26 A 1:500 CT-26V >200 kHz CT-52 >500 kHz ±52 A 1:1000 CT-52V >200 kHz CT-100 >500 kHz ±100 A 1:1000 CT-100V >200 kHz CT-150 >300 kHz ±150 A 1:1500 CT-150V >200 kHz Equivalent Input Noise <1 ppm @ BW = 200 Hz <10 ppm @ BW = 50 kHz <1 ppm @ BW = 200 Hz <10 ppm @ BW = 50 kHz <1 ppm @ BW = 200 Hz <10 ppm @ BW = 50 kHz <1 ppm @ BW = 200 Hz <10 ppm @ BW = 50 kHz <1 ppm @ BW = 200 Hz <10 ppm @ BW = 50 kHz Output Type Current Voltage Max DC secondary current / Max voltage output < 0.5 ppm/K ✔ ✗ ±52 mA typ. < 2 ppm/K ✗ ✔ < 0.5 ppm/K ✔ ✗ Temperature Coefficient - TC Max external Shunt Resistor Supply Voltage Mounting PCB Panel 40 Ω ✔ ✗ ±10.4 V n/a ✔ ✗ ±52 mA 40 Ω ✔ ✗ .! typ. < 2 ppm/K ✗ ✔ ±10.4 V n/a ✔ < 0.5 ppm/K ✔ ✗ ±52 mA 40 Ω ✔ typ. < 2 ppm/K ✗ ✔ ±10.4 V n/a ✔ < 0.5 ppm/K ✔ ✗ ±100 mA 40 Ω ✔ ✔ typ. < 2 ppm/K ✗ ✔ ±10V n/a ✔ ✔ < 0.5 ppm/K ✔ ✗ ±100 mA 48 Ω typ. < 2 ppm/K ✗ ✔ ±10V n/a Primary Conductor Hole Diameter Mechanical Dimensions Internal 66 x 64 x 48 mm 16 mm 45 x 57 x 75 mm ✗ ✗ ✗ ✔ ✔ ✔ ✔ ±15 V CT-200 ±200 A 1:1000 >100 kHz CT-200V CT-300 ±300 A 1:1500 >100 kHz CT-300V CT-400 ±400 A 1:2000 >100 kHz CT-400V CT-600 ±600 A 1:1500 >150 kHz CT-1000 CT-1000V C 1:2000 <10 ppm @ BW = 50 kHz <1.5 ppm @ BW = 200 Hz <10 ppm @ BW = 50 kHz <1.5 ppm @ BW = 200 Hz <10 ppm @ BW = 50 kHz <1.5 ppm @ BW = 200 Hz <10 ppm @ BW = 50 kHz CT-600V ±1000 A <1.5 ppm @ BW = 200 Hz >150 kHz <1.5 ppm @ BW = 200 Hz <10 ppm @ BW = 50 kHz < 0.5 ppm/K ✔ typ. < 2 ppm/K Temperature Range 0°C – 50°C ✗ ±200 mA 40 Ω ✗ ✔ ✗ ✔ ±10V n/a ✗ ✔ < 0.5 ppm/K ✔ ✗ ±200 mA 30 Ω ✗ ✔ typ. < 2 ppm/K ✗ ✔ ±10V n/a ✗ ✔ < 0.5 ppm/K ✔ ✗ ±200 mA 25 Ω ✗ ✔ typ. < 2 ppm/K ✗ ✔ ±10V n/a ✗ ✔ < 0.5 ppm/K ✔ ✗ ±400 mA 30 Ω ✗ ✔ typ. < 2 ppm/K ✗ ✔ ±10V n/a ✗ ✔ < 0.5 ppm/K ✔ ✗ ±500 mA 20 Ω ✗ ✔ typ. < 2 ppm/K ✗ ✔ ±10V n/a ✗ ✔ 94 x 91 x 50 mm 30.7 mm 107 x 91 x 50 mm Copyright©CAENELSd.o.o.–2015 Allrightsreserved.Informa6oninthispublica6onsupersedesallearlierversions. Specifica6onssubjecttochangewithoutno6ce. Rev1.0–PrintedinOctober2015. PRECISION CURRENT TRANSDUCERS ! -Selec'onTable C < ProductOverview CT-200 CT-300 CT-400 PrecisionCurrent Transducers ! Currentor Voltage Output CT-200/CT-300/CT-400 ●Closed-loopcurrenttransformertechnologyallowsaccuratemonitoringofDCandAC bipolarcurrentsupto±200A(CT-200),±300A(CT-300)or±400A(CT-400). ●GalvanicisolaJonbetweenprimaryandsecondaryconductorforsimplecurrentsensingat differentpotenJal. ●Standardcurrentoutputandvoltageoutput(“V”-version)available. FEATURES •MonitoringofDCandACcurrents •ExcellentLinearity •Closed-loopdetecHon •Galvanicallyisolatedfromprimary •LowTemperatureDrie The0-FLUCS(0-FLUxCurrentSensor) familyisbasedonaclosedloop technologythatallowsaccurateand precisemonitoringofDCandAC currentswithhighbandwidth. TheCT-200/CT-300/CT-400transducers •WideBandwidth areratedatamaximumbipolarprimary currentof200A/300A/400Awitha transformraHoofrespecHvely1:1000, •HighAccuracy 1:1500and1:2000. •UL94V-0flammabilitygrade •LEDindicatescorrectoperaHon GalvanicisolaHonbetweentheprimary •DB-9Connectorforrack/panelmounHng andthesecondarycircuitsallowsto measurecurrentsatadifferentpotenHal andsimplifiesinterfacingwhenusing •Current-outputorVoltage-output versions APPLICATIONS •PowerSupplies •SensingElementinCalibraHonSystems •BiomedicalDevices •NuclearMagneHcResonance(NMR) •Test&MeasurementSetups the0-FLUCSasthefeedbackelementof currentregulatedpowersupplies. Outputfromthe0-FLUCStransducers canbechosenbetweentwodifferent versions:secondarycurrentoutputor bufferedvoltageoutput(lowTCshunt resistorandlow-noiseamplifierare embeddedinthedevice). AstandardDB-9connectorisusedfor thetransducerconnecHons. MaincharacterisHcsofthe0-FLUCS currenttransformersarenegligible temperaturecoefficientonthe secondaryoutputcurrent,excellent linearityandextremelylownoise. DCcurrenttransformersrepresentsthe idealreplacementforsystemswhere Hall-effectsensorsareusedascurrent sensingelementsandbe|er performancesareneeded. AllCT-200/CT-300/CT-400devices alsohavedifferentmounHngholesin ordertobeeasilyinstalledindifferent configuraHons.Bothself-threadingscrews andnormalonescanbeused. MainapplicaHonfieldsforthesecurrent transducersarepreciseandextremely stableregulatedpowersuppliesand powerinverters. DuetotheexcellentcharacterisHcs,the0FLUCStransducerscanbeusedina varietyofcalibraHon,acceptance C AboutUs CAENELSisaleadingcompanyinthedesign tesHngandqualitycontrolapplicaHons inindustrial,powergeneraHonand automoHvefields. Commerciallyavailableversionsofthe CT-200/CT-300/CT-400current transformersarethestandard current-outputandthevoltage-output “V”version. DifferentoutputvoltageraHngs–e.g. ±2.5Vor±5V–areavailableupon requestforaminimumquanHty ofpowersuppliesandstate-of-the-art completeelectronicsystemsforthePhysics CT-200 CT-300 CT-400 dedicatedsoluJonsfortheparJcle CurrentTransformRaHo-N 1:1000 1:1500 1:2000 acceleratorcommunityandhigh-end MaximumDCPrimaryCurrent-IP(DC) ±200A ±300A ±400A MaximumRMSPrimaryCurrent-IP(RMS) 141A 212A 283A researchworld,havingitsmainfocuson industrialapplicaJons. TechnicalSpecificaJons CurrentPolarity Bipolar • PowerSupplySystems MaximumDCSecondaryCurrent-IS(DC) ±200mA • PrecisionCurrentMeasurements MaximumRMSSecondaryCurrent-IS(RMS) 141mA • BeamlineElectronicInstrumentaJon ExternalShuntResistorValue–RS 0…40Ω 0…30Ω 0…20Ω FMC&MTCA.4–MicroTCAforPhysics SmallSignalBandwidth–typ.BW >200kHz >200kHz >200kHz • SmallSignalBandwidth–“V”version–typ.BW CAENELSd.o.o. Noise(RMS)–typ. 100kHz 150kHz 150kHz <1.5ppm(@200Hz) <6ppm(@50kHz) <1.8ppm(@200Hz) <7ppm(@50kHz) <2ppm(@200Hz) <8ppm(@50kHz) 0.05V/A (1/30)V/A Kraškaulica,2 6210–Sežana Slovenija Phone+386(0)57313585 Fax+386(0)57313587 [email protected] www.caenels.com OutputVoltage(“V”-version)-VOUT ±10V OutputVoltageRaHo(“V”version)–VOUT/IP(DC) MaximumOutputCurrent–“V”-version ±15mA <0.5ppm/K <2ppm/K(“V”-version) TemperatureCoefficient–TC(typ.) InducHonintoPrimary(typ.) 5µV(RMS) Offset(withfactorytrimming) <10ppm/FS ProtecHonSignal Yes-PrimaryOver-Current SupplyVoltage(±6%) www.caenels.com 0.025V/A ±15V MaximumCurrentConsumpHon 50mA+IS ConnecHons DB-9Connector Mechanical(Outer)Dimensions 94×91×50mm PrimaryConductorHoleDiameter–Ø 30mm MaximumWeight 380g PS1215I–PS1215V Low-NoisePowerSupplies forcurrenttransducers <! StatusLEDandsignal 0-FLUCS Closed–Loop Technology The CT-200, CT-300 and CT-400 models are based on the CAEN ELS 0-FLUCS Closed-Loop Technology. OrderingOpJons C WCT200CXAAAA CT-200 200APrimaryCurrent0-FLUCS,DB-9connector WCT200VCXAAA CT-200V 200APrimaryCurrent0-FLUCS,DB-9connector,Voltage-Output WCT300CXAAAA CT-300 300APrimaryCurrent0-FLUCS,DB-9connector WCT300VCXAAA CT-300V 300APrimaryCurrent0-FLUCS,DB-9connector,Voltage-Output WCT400CXAAAA CT-400 400APrimaryCurrent0-FLUCS,DB-9connector WCT400VCXAAA CT-400V 400APrimaryCurrent0-FLUCS,DB-9connector,Voltage-Output Copyright©CAENELSd.o.o.–2015 Allrightsreserved.InformaHoninthispublicaHonsupersedesallearlierversions. SpecificaHonssubjecttochangewithoutnoHce. Rev1.0–PrintedinOctober2015. C < ProductOverview CT-600 CT-1000 PrecisionCurrent Transducers Currentor Voltage Output ! CT-600/CT-1000 ●Closed-loopcurrenttransformertechnologyallowsaccuratemonitoringofDCandAC bipolarcurrentsupto±600A(CT-600)andto±1000A(CT-1000). ●GalvanicisolaJonbetweenprimaryandsecondaryconductorforsimplecurrentsensingat differentpotenJal. ●Standardcurrentoutputandvoltageoutput(“V”-version)available. FEATURES •MonitoringofDCandACcurrents •ExcellentLinearity •Closed-loopdetecHon •Galvanicallyisolatedfromprimary •LowTemperatureDrie •Current-outputorVoltage-output versions •WideBandwidth •HighAccuracy •UL94V-0flammabilitygrade •LEDindicatescorrectoperaHon •DB-9Connectorforrack/panelmounHng APPLICATIONS •PowerSupplies •SensingElementinCalibraHonSystems •BiomedicalDevices •NuclearMagneHcResonance(NMR) •Test&MeasurementSetups The0-FLUCS(O-FLUxCurrentSensor) familyisbasedonaclosedloop technologythatallowsaccurateand precisemonitoringofDCandAC currentswithhighbandwidth. TheCT-600andCT-1000transducersare ratedatamaximumbipolarprimary currentof600Aand1000Awitha transformraHoof1:1500and1:2000. GalvanicisolaHonbetweentheprimary andthesecondarycircuitsallowsto measurecurrentsatadifferentpotenHal andsimplifiesinterfacingwhenusing the0-FLUCSasthefeedbackelementof currentregulatedpowersupplies. Outputfromthetransducerscanbe chosenbetweentwodifferentversions: secondarycurrentoutputorbuffered voltageoutput(lowTCshuntresistor MaincharacterisHcsofthe0-FLUCS currenttransformersarenegligible temperaturecoefficientonthe secondaryoutputcurrent,excellent linearityandextremelylownoise. DCcurrenttransformersrepresentsthe idealreplacementforsystemswhere Hall-effectsensorsareusedascurrent sensingelementsandbe|er performancesareneeded. AllCT-600andCT-1000devicesalsohave differentmounHngholesinordertobe easilyinstalledindifferentconfiguraHons. Bothself-threadingscrewsandnormal onescanbeused. MainapplicaHonfieldsforthesecurrent transducersarepreciseandextremely stableregulatedpowersuppliesand powerinverters. andlow-noiseamplifierareembeddedin thedevice). DuetotheexcellentcharacterisHcs,the CT-600andCT-1000transducerscanbe AstandardDB-9connectorisusedfor usedinavarietyofcalibraHon, thetransducerconnecHons. C AboutUs CAENELSisaleadingcompanyinthedesign acceptancetesHngandqualitycontrol applicaHonsinindustrial,power generaHonandautomoHvefields. thestandardcurrent-outputCT-600 andCT-1000andthevoltage-output versionCT-600VandCT-1000V. Commerciallyavailableversionsofthe CT-600andCT-1000currentsensorsare DifferentoutputvoltageraHngs–e.g. ±2.5Vor±5V–areavailableupon requestforaminimumquanHty. ofpowersuppliesandstate-of-the-art completeelectronicsystemsforthePhysics CT-600 CT-1000 CurrentTransformRaHo-N 1:1500 1:2000 industrialapplicaJons. MaximumDCPrimaryCurrent-IP(DC) ±600A ±1000A MaximumRMSPrimaryCurrent-IP(RMS) 424A 707A researchworld,havingitsmainfocuson dedicatedsoluJonsfortheparJcle acceleratorcommunityandhigh-end • PowerSupplySystems • PrecisionCurrentMeasurements • BeamlineElectronicInstrumentaJon • FMC&MTCA.4–MicroTCAforPhysics TechnicalSpecificaJons CurrentPolarity Bipolar MaximumDCSecondaryCurrent-IS(DC) ±400mA ±500mA MaximumRMSSecondaryCurrent-IS(RMS) 283mA 354mA ExternalShuntResistorValue–RS 0…30Ω 0…20Ω SmallSignalBandwidth(-1dB)–typ.BW >150kHz <1.5ppm(@200Hz) <7ppm(@50kHz) Noise(RMS)–typ. CAENELSd.o.o. Kraškaulica,2 6210–Sežana Slovenija Phone+386(0)57313585 Fax+386(0)57313587 [email protected] www.caenels.com OutputVoltage(“V”-version)-VOUT ±10V OutputVoltageRaHo(“V”version)–VOUT/IP(DC) (1/60)V/A MaximumOutputCurrent–“V”-version 0.01V/A ±15mA <0.5ppm/K <2ppm/K(“V”-version) TemperatureCoefficient–TC(typ.) InducHonintoPrimary(typ.) 5µV(RMS) Offset(withfactorytrimming) 10µV(RMS) <10ppm/FS ProtecHonSignal Yes-PrimaryOver-Current SupplyVoltage(±6%) ±15V MaximumCurrentConsumpHon www.caenels.com <1.5ppm(@200Hz) <10ppm(@50kHz) 50mA+IS ConnecHons DB-9Connector Mechanical(Outer)Dimensions 107×91×50mm PrimaryConductorHoleDiameter–Ø 30mm MaximumWeight 450g 600g PS1215I–PS1215V Low-NoisePowerSupplies forcurrenttransducers 0-FLUCS Closed–Loop Technology <! The CT-200, CT-300 and CT-400 models are based on the CAEN ELS 0-FLUCS Closed-Loop Technology. StatusLEDandsignal OrderingOpJons C WCT600CAAAAA CT-600 600APrimaryCurrent0-FLUCS,DB-9connector WCT600VXAAAA CT-600V 600APrimaryCurrent0-FLUCS,DB-9connector,Voltage-Output WCT1000XAAAA CT-1000 1000APrimaryCurrent0-FLUCS,DB-9connector WCT1000VXAAA CT-1000V 1000APrimaryCurrent0-FLUCS,DB-9connector,Voltage-Output Copyright©CAENELSd.o.o.–2015 Allrightsreserved.InformaHoninthispublicaHonsupersedesallearlierversions. SpecificaHonssubjecttochangewithoutnoHce. Rev1.0–PrintedinOctober2015. C ProductOverview PrecisionCurrent Transducers < PS1215I PS1215V Low-Noise PowerSupplyfor CurrentTransducers ! PS1215 ●LowNoiseMixedBipolarAC/DCPowerSupplyforopJmaloperaJonofthe< CurrentTransducers. ●ExtendedInputRangeforVoltageandFrequency. ●“I”and“V”versionsincludecablesforCurrentandVoltageOutputTransducers respecJvely. FEATURES •MixedSwitching/LinearTopology •27WBipolarOutput-±15V •LowNoise •ExtendedACInputRange •Current-outputorVoltage-output versionswithcables •LEDsindicatecorrectoperaHon •Three-polescrewlockingconnector APPLICATIONS •PowerSupplyfor<Transducers •BipolarSupplyforPreciseInstrumentaHon •Test&MeasurementSetups ThePS1215isasingle-output,dualvoltagemixedswitching-linearpower supplythatisdesignedinordertoobtain low-noiseoperaHonandhighefficiency anditisespeciallysuitedforopHmal performancesofcurrentmeasurement systemswhereswitchingpowersupplies couldcorruptthemeasurewithnoise, lessaccuracyandlessprecision. Thepowersupplyishousedinarobust andcompactstainlesssteelboxthatcan beplacedclosetothesupplieddevicein ordertoreducecablelengthsand minimizeconsequentpossiblenoise pick-up. ThesepowersuppliesareparHcularly designedforoperaHonwithCAENELS DCCurrentTransducers(DCCT)ofthe <series. ThePS1215powersupplyhasanoutput voltageaccuracyof±3%onbothits posiHveandnegaHveoutputs. Maximumpeak-to-peakvoltagenoise measuredatthedeviceoutputterminals isratedat4mV(measuredatfullload). OutputDCvoltagesaremadeavailable througha3-poleconnectorwithascrew lockingthatallowssecuringthe connecHon. ThePS1215powersupplycanbeordered inthreedifferentversions,differingby theoutputcabling. ThePS1215Iversionalsoincludesthe DB-9connectorandtwo“banana”-type plugsforthecurrentoutputofstandard transducers,thePS1215Vversion includesthesamecablingwithBNC coaxialconnectorforvoltage-output ones. C AboutUs TechnicalSpecificaJons PS1215 OutputPosiHveVoltage(±3%) +15V OutputNegaHveVoltage(±3%) -15V MaximumOutputPower 27W MaximumOutputCurrent +15V@900mA -15V@900mA OutputRipple+Noise 0.003%RMS@DC-1MHz 0.025%PEAK-PEAK@DC-1MHz ACLineVoltageInput 90–260VAC ACLineFrequency 47-63Hz InputtoOutputIsolaHon 3kV CAENELSisaleadingcompanyinthedesign ofpowersuppliesandstate-of-the-art completeelectronicsystemsforthePhysics researchworld,havingitsmainfocuson dedicatedsoluJonsfortheparJcle acceleratorcommunityandhigh-end industrialapplicaJons. OutputtoEarth-CaseIsolaHon 500V • PowerSupplySystems Hold-upHme 16ms(typ.)at115VAC • PrecisionCurrentMeasurements • BeamlineElectronicInstrumentaJon • FMC&MTCA.4–MicroTCAforPhysics CAENELSd.o.o. Kraškaulica,2 6210–Sežana Slovenija Cooling NaturalconvecHon Dimensions 136.4×41×90.7mm Weight 600g Y-Cablelength(CT-IandCT-V) 3m Indicators 2LEDs ProtecHons Outputshort-circuit Outputover-voltage OperaHngTemperatureRange 0°C–50°C Phone+386(0)57313585 Fax+386(0)57313587 PS1215V AC-DCPowerSupplyandcablesfor Voltage-OutputCurrentTransducers [email protected] www.caenels.com www.caenels.com 0-FLUCS Closed–Loop Technology The PS1215 models are designed for optimal operation for PS1215I the CAEN ELS 0-FLUCS current transducers. AC-DCPowerSupplyandcablesfor Current-OutputCurrentTransducers OrderingOpJons WPS1215XAAAA PS1215 PS1215-AC/DCSingleOutput-DualVoltage±15VLowNoisePowerSupply-27Wmax-3mcable WPS1215IXAAA PS1215I PS1215-AC/DCSingleOutput-DualVoltage±15VLowNoisePowerSupply-27Wmax+Y-CableCT-I:3mcablewithDB-9and“banana”plugs(currentoutput) WPS1215VXAAA PS1215V PS1215-AC/DCSingleOutput-DualVoltage±15VLowNoisePowerSupply-27Wmax+Y-CableCT-V:3mcablewithDB-9andBNC(voltageoutput) C Copyright©CAENELSd.o.o.–2015 Allrightsreserved.InformaHoninthispublicaHonsupersedesallearlierversions. SpecificaHonssubjecttochangewithoutnoHce. Rev1.0–PrintedinOctober2015. FrequencyResponse PrecisionCurrent Transducers < ACPerformances ●CT-150AmplitudeandPhaseResponse ! 2.0 Amplitude[dB] 1.5 1.0 AmplitudeResponse 0.5 0.0 -0.5 1 10 100 1000 10000 100000 -1.0 Frequency Amplitude DC…50kHz <0.02dB 50…200kHz <0.5dB 200…400kHz <1dB -1.5 -2.0 5 Phase[deg] 0 -5 1 10 100 1000 10000 100000 PhaseResponse -10 -15 -20 Frequency PhaseShik DC…2kHz <0.1° 2Hz…40kHz <0.5° 40…400kHz <2° -25 -30 Frequency[Hz] MaximumCurrentRaJngs AbsoluteRaJngs ●AbsoluteMaximumRaJngsforSingle-PulsePrimaryCurrentOverload Model ConJnuous* for10s for1s For0.1s ±78A CT-13 ±14A ±16A ±26A CT-13V ±13.5A ±16A ±26A ±65A CT-26 ±28A ±32A ±52A ±156A CT-26V ±27A ±32A ±52A ±130A CT-52 ±52A ±62A ±104A ±208A CT-52V ±52A ±62A ±104A ±208A CT-100 ±105A ±125A ±200A ±600A CT-100V ±105A ±125A ±200A ±500A CT-150 ±157A ±180A ±300A ±900A CT-150V ±155A ±180A ±300A ±750A CT-200 ±210A ±250A ±400A ±1200A CT-200V ±205A ±250A ±400A ±1000A CT-300 ±315A ±360A ±600A ±1800A CT-300V ±310A ±360A ±600A ±1500A CT-400 ±420A ±480A ±800A ±2400A CT-400V ±410A ±480A ±800A ±2000A CT-600 ±630A ±720A ±1200A ±3600A CT-600V ±620A ±720A ±1200A ±3000A CT-1000 ±1020A ±1200A ±2000A ±5000A CT-1000V ±1010A ±1200A ±2000A ±5000A *SpecificaHonsovertheratedcurrentsarenotguaranteed < C Precision Current Measurements CAEN ELS d.o.o. kraška ulica 2 6210 – Sežana Slovenija www.caenels.com [email protected]