Current Measurement Catalogue 2015 Web

Product Catalogue
2015
<
C
Precision Current
Measurements
PrecisionCurrent
Transducers
<
CT-BOX
!
2
DigitalCurrentTransducerBoxfortheHighestAccuracyCurrentMeasurements
4
CT-PCBSeries
13A,26Aand52AFull-ScalePrecisionCurrentTransducersforPCBMounJng
CT-100/CT-150
6
100Aand150AFull-ScalePrecisionCurrentTransducersforRack/PanelandPCBMounJng
<
8
CT-200/CT-300/CT-400
INDEX
-SelecJonGuide
9
200A,300Aand400AFull-ScalePrecisionCurrentTransducersforRack/PanelMounJng
11
CT-600/CT-1000
600Aand1000AFull-ScalePrecisionCurrentTransducersforRack/PanelMounJng
PS1215
13
Low-NoiseBipolarPowerSupplyforCurrentTransducers
C
15
FrequencyResponse
MaximumCurrentRaJngs
C
ProductOverview
CT-BOX
DigitalCurrentTransducerBox
fortheHighestAccuracyCurrentMeasurements
PrecisionCurrent
Transducers
<
!
CT-BOX
●Preciseandaccuratecurrentmeasuringsystemincludescurrenttransducerandmeasuring
unitinordertoobtainbest-in-classperformances.
●InternalcalibraJonandthermalstabilizaJontoobtainexcellentstabilityofcurrent
measurements.
●Data-loggerandoscilloscopemodesofoperaJon
FEATURES
•DigitalInterface
-Ethernet
-USB
-RS-232
•<1ppm/KTemperatureCoefficient
•<0.005%Full-ScaleAccuracy(with
High-AccuracyCalibraHonOpHon)
•ConfigurableRecorderonmicroSD-Flash
•TriggerInput/OutputandAlarmOutput
•ExternalTemperatureSensors
•AnalogMonitor
•LocalDisplayforCurrentReadings
•DesktoporRackMounHngin1U
•IntegratedFan-lessAC/DCPowerSupply
•DedicatedSoewareApplicaHon
APPLICATIONS
•Test&MeasurementSetups
•SensingElementinCalibraHonSystems
•PowerSupplies
•BiomedicalDevices
TheCT-BOXisastand-alonesystem
designedtomeasurewiththehighest
accuracyandprecisionDCandAC
currents,providingthereadingsin
differentdigitalformats.
TheCT-BOXsystemisdevelopedtobe
usedwiththe0-FLUCScurrentoutput
DCCTsallowingmeasurementsof
currentsuptokA.
Thesystemintegratesaburdenresistor
andacondiHoningnetworkfeedinga
24-bittemperaturestabilizedADCin
ordertohave<1ppm/Ktemperature
dependence.ThedigitalsecHon
interfacedtotheADCperformsa
calibratedmeasurementinorderto
eliminatethenon-idealbehaviorthus
providinga0.005%Full-scalecurrent
valueaccuracy(opHonal).TheADC
samplingfrequencycanbeconfigured
upto100kHzallowingtoacquirehigh
frequencycomponentsandfastcurrent
transients.
Currentreadingscanbetriggeredin
differentmodes:
•byanexternalLVTTLorTTLsignal;
•byaremotecommandsenttothe
digitalinterface;
•internally,se\ngthesamplingperiod
andtheacquisiHonwindow.
TheHme-stamp,thecurrentreadingsand
theexternaltemperaturevaluesare
storedinamicroSDFlashmemory
allowinglong-termacquisiHons.
ThemicroSDmemorycanbeeitherread
viaEthernet,USBorRS-232interfacesor
removedfromthesystemandtransferred
tootherdevicesinordertodownloadits
content.
Atemperatureprobecanbepluggedon
thebackofthesystemifneededinorder
toalsoreadandstoreexternal
temperaturevalues.
Alocaldisplayshowingcurrentreadings
aswellasotherse\ngs–e.g.IPaddress,
modeofoperaHon–ispresent.
Aconfigurablealarmoutputcanbeused
tosignaltoanexternaldeviceifapre-set
currentthresholdhasbeenexceeded.
C
AboutUs
CAENELSisaleadingcompanyinthedesign
AnintegratedfuncHonallowsto
compensateformeasurementsetup
offsetcurrents.
CT-BOXdirectlytotheACmains.
Theextremelycompactdesign
Theunitintegratesalow-noisemixed
AC/DCpowersupplytoconnectthe
(1U–9”)allowsusingtheinstrument
asbenchmarkortoinstallthe
systemsina1U-19”rack.
ofpowersuppliesandstate-of-the-art
completeelectronicsystemsforthePhysics
researchworld,havingitsmainfocuson
dedicatedsoluJonsfortheparJcle
acceleratorcommunityandhigh-end
TechnicalSpecificaJons
ACLineInput
industrialapplicaJons.
MaximumPowerConsumpHon
CurrentAccuracy
25W
<0.01%(standard)
<0.005%(High-AccuracyopHon)
• 
PowerSupplySystems
• 
PrecisionCurrentMeasurements
• 
BeamlineElectronicInstrumentaJon
ThermalCoefficient(typ.)
• 
FMC&MTCA.4–MicroTCAforPhysics
CurrentRangesAvailable[A]
CurrentResoluHon
24-bit
SamplingFrequency
0.1Hz–100kHz
<1ppm/K
100,150,200,300,400,600,1000
CurrentReadings
7½digits
NumberofMemoryReadings
CAENELSd.o.o.
CT-BOX
90-260V(AC),46-440Hz
dependingonmicroSDcardcapacity
PowerOK,DCCTconnected,Status,
SDreading/wriHng,AcquisiHonrunning
Kraškaulica,2
6210–Sežana
Slovenija
LEDIndicators
Phone+386(0)57313585
Fax+386(0)57313587
TemperatureProbeAccuracy
TemperatureProbeResoluHon
0.1°C
±0.5°C
TemperatureAccuracy
0.05%
[email protected]
www.caenels.com
www.caenels.com
DigitalInterfaces
Ethernet10/100MbpsTCP-IP
USB2.0
RS-232
AnalogMonitor
±10V(LEMOconnector)
TriggerInputs
DigitalInterface(soe-trigger)
TTL5V–LVTTLcompaHble
AlarmOutput
TTL5V
SolidStateRelay
MechanicalDimensions(L×W×H)
OperaHngTemperature
180×220×41mm
0…40°C
CT-BOX
alsofor1U–19’’installa0on
<
Current Transducers
OrderingOpJons
WCTBOX100XAA
CT-BOX-100
100ACurrentTransducerDigitalBoxwithLocalDisplayandEthernet,USB,RS-232CommunicaHonInterfaces
WCTBOX150XAA
CT-BOX-150
200ACurrentTransducerDigitalBoxwithLocalDisplayandEthernet,USB,RS-232CommunicaHonInterfaces
WCTBOX200XAA
CT-BOX-200
200ACurrentTransducerDigitalBoxwithLocalDisplayandEthernet,USB,RS-232CommunicaHonInterfaces
WCTBOX300XAA
CT-BOX-300
300ACurrentTransducerDigitalBoxwithLocalDisplayandEthernet,USB,RS-232CommunicaHonInterfaces
WCTBOX400XAA
CT-BOX-400
400ACurrentTransducerDigitalBoxwithLocalDisplayandEthernet,USB,RS-232CommunicaHonInterfaces
WCTBOX600XAA
CT-BOX-600
600ACurrentTransducerDigitalBoxwithLocalDisplayandEthernet,USB,RS-232CommunicaHonInterfaces
WCTBOX1000XA
CT-BOX-1000
1000ACurrentTransducerDigitalBoxwithLocalDisplayandEthernet,USB,RS-232CommunicaHonInterfaces
WCTBOXMBXAAA
CT-BOX-MB
CT-BOXmounHngbracketsfor1U–19”cabinetinstallaHon
WCTBOX1YXAAA
CT-BOX-YC
CT-BOXIn-HouseYearlyCalibraHonService(<0.01%accuracy)
WCTBOXSICLXA
CT-BOX-HAC
CT-BOXHigh-AccuracyCalibraHonService(<0.005%accuracy)
C
Copyright©CAENELSd.o.o.–2015
Allrightsreserved.InformaHoninthispublicaHonsupersedesallearlierversions.
SpecificaHonssubjecttochangewithoutnoHce.
Rev1.0–PrintedinOctober2015.
C
<
ProductOverview
CT-13
CT-26
CT-52
PrecisionCurrent
Transducers
!
Currentor
Voltage
Output
CT-PCBSeries
●Closed-loopcurrenttransformertechnologyallowsaccuratemonitoringofDCandAC
bipolarcurrentsupto±52AwithasmallPCB-mountdevice.
●GalvanicisolaJonbetweenprimaryandsecondaryconductorforsimplecurrentsensingat
differentpotenJal.
●Standardcurrentoutputandvoltageoutput(“V”-version)available.
FEATURES
•MonitoringofDCandACcurrents
•ExcellentLinearity
•Closed-loopdetecHon
•Galvanicallyisolatedfromprimary
•LowTemperatureDrie
•Current-outputorVoltage-output
versions
•WideBandwidth
•HighAccuracy
•UL94V-0flammabilitygrade
•LEDindicatescorrectoperaHon
•PCB-mountversions
APPLICATIONS
•PowerSupplies
•SensingElementinCalibraHonSystems
•BiomedicalDevices
•Test&MeasurementSetups
The0-FLUCS(0-FLUxCurrentSensor)
familyisbasedonaclosedloop
andlow-noiseamplifierareembedded
intheCT-13V,CT-26VandCT-52V).
technologythatallowsaccurateand
precisemonitoringofDCandAC
currentswithhighbandwidth.Themetal
MaincharacterisHcsofthe0-FLUCS
currenttransformersarenegligible
casingguaranteeshighernoiseimmunity
andreducesundesirednoisepick-up
fromexternalsources.
temperaturecoefficientonthe
secondaryoutputcurrent,excellent
linearityandextremelylownoise.
ThetransducersCT-13,CT-26andCT-52
arePCB-mountdevicesratedat
DCcurrenttransformersrepresentthe
idealreplacementforsystemswhere
maximumcurrentsof13A,26Aand52A
withprimarytosecondaryraHoof1:250,
1:500and1:1000respecHvely.
Hall-effectsensorsareusedascurrent
sensingelementsandbe|er
performancesareneeded.
GalvanicisolaHonbetweentheprimary
andthesecondarycircuitsallowsto
measurecurrentsatadifferentpotenHal
Thecompactmechanicaldimensionsof
thistransducerseriesanditslimited
andsimplifiesinterfacingwhenusing
theO-FLUCSasthefeedbackelement
ofcurrentregulatedpowersupplies.
weightallowforeasymounHngon
printedcircuitboardswithaThrough
Hole(TH)topology.AplasHccoveris
OutputfromtheCT-PCBsensorscanbe
placedonthebo|omsideofthedevice
toallowforeasiermounHngonthePCB.
chosenbetweentwodifferent
versions:standardsecondarycurrent
MainapplicaHonsforthesecurrent
transducersarepreciseandstable
outputorbufferedvoltageoutput(low
temperaturecoefficientshuntresistor
regulatedpowersuppliesandpower
inverters.
C
AboutUs
CAENELSisaleadingcompanyinthedesign
DuetotheexcellentcharacterisHcs,the
CTPCBtransducerscanbeused
inavarietyofcalibraHon,acceptance
tesHngandqualitycontrolapplicaHons
inindustrial,powergeneraHonand
Commerciallyavailableversionsof
theCT-13,CT-26andCT-52with
theirrespecHve“V”voltage-output
versionsCT-13V,CT-26VandCT-52V.
automoHvefields.
ofpowersuppliesandstate-of-the-art
completeelectronicsystemsforthePhysics
researchworld,havingitsmainfocuson
TechnicalSpecificaJons
dedicatedsoluJonsfortheparJcle
CurrentTransformRaHo-N
industrialapplicaJons.
MaximumDCPrimaryCurrent-IP(DC)
MaximumRMSPrimaryCurrent-IP(RMS)
9.2A
acceleratorcommunityandhigh-end
• 
PowerSupplySystems
• 
PrecisionCurrentMeasurements
• 
BeamlineElectronicInstrumentaJon
• 
FMC&MTCA.4–MicroTCAforPhysics
CT-13
CT-26
CT-52
1:250
1:500
1:1000
±13A
±26A
±52A
18.4A
36.8A
CurrentPolarity
Bipolar
MaximumDCSecondaryCurrent-IS(DC)
±52mA
MaximumRMSSecondaryCurrent-IS(RMS)
37mA
SmallSignalBandwidth–typ.
500kHz
SmallSignalBandwidth–“V”-version–typ.
>200kHz
<1ppm(@200Hz)
<10ppm(@50kHz)
Noise(RMS)–typ.
CAENELSd.o.o.
Kraškaulica,2
6210–Sežana
Slovenija
Phone+386(0)57313585
Fax+386(0)57313587
[email protected]
www.caenels.com
OutputVoltage(“V”-version)-VOUT
OutputVoltageRaHo(“V”version)–VOUT/IP(DC)
±10V
0.8V/A
0.4V/A
MaximumOutputCurrent–“V”-version
±15mA
<0.5ppm/K
<2ppm/K(“V”-version)
TemperatureCoefficient–TC(typ.)
ProtecHonSignal
Yes–OKStatus
SupplyVoltage(±6%)
±15V
ConnecHons
16-pinthrough-holePCBmounHng
Mechanical(Outer)Dimensions
www.caenels.com
0.2V/A
66×68×48mm
PrimaryConductor
Internal
MaximumWeight
300g
CT-PCBVoltageOutput–“V”Version
<!
DC+20-kHzsine-waveprimarycurrent–i.e.I
P[A]–andoutput
voltageofaCT-13Vversion–i.e.VO[V]
0-FLUCS Closed–Loop Technology
The CT-PCB current transducer series is based on the
CAEN ELS 0-FLUCS Closed-Loop Technology.
OrderingOpJons
C
WCT13XAAAAAA
CT-13
WCT26XAAAAAA
CT-26
13APrimaryCurrentO-FLUCS,PCB-MounHng
26APrimaryCurrentO-FLUCS,PCB-MounHng
WCT52VXAAAAA
CT-52
52APrimaryCurrentO-FLUCS,PCB-MounHng,
WCT13VXAAAAA
CT-13V
13APrimaryCurrentO-FLUCS,PCB-MounHng,Voltage-Output
WCT26VXAAAAA
CT-26V
26APrimaryCurrentO-FLUCS,PCB-MounHng,Voltage-Output
WCT52VXAAAAA
CT-52V
52APrimaryCurrentO-FLUCS,PCB-MounHng,Voltage-Output
Copyright©CAENELSd.o.o.–2015
Allrightsreserved.InformaHoninthispublicaHonsupersedesallearlierversions.
SpecificaHonssubjecttochangewithoutnoHce.
Rev1.0–PrintedinOctober2015.
C
<
ProductOverview
CT-100
CT-150
PrecisionCurrent
Transducers
Currentor
Voltage
Output
!
CT-100/CT-150
●Closed-loopcurrenttransformertechnologyallowsaccuratemonitoringofDCandAC
bipolarcurrentsupto±100A(CT-100)orupto±150A(CT-150).
●GalvanicisolaJonbetweenprimaryandsecondaryconductorforsimplecurrentsensingat
differentpotenJal.
●Standardcurrentoutputandvoltageoutput(“V”-version)available.
FEATURES
•MonitoringofDCandACcurrents
•ExcellentLinearity
•Closed-loopdetecHon
•Galvanicallyisolatedfromprimary
•LowTemperatureDrie
•Current-outputorVoltage-output
versions
•WideBandwidth
•HighAccuracy
•UL94V-0flammabilitygrade
•LEDindicatescorrectoperaHon
•DB-9ConnectororPCB-mountversions
APPLICATIONS
•PowerSupplies
•SensingElementinCalibraHonSystems
•BiomedicalDevices
•NuclearMagneHcResonance(NMR)
•Test&MeasurementSetups
The0-FLUCS(0-FLUxCurrentSensor)
familyisbasedonaclosedloop
technologythatallowsaccurateand
precisemonitoringofDCandAC
currentswithhighbandwidth.
TheCT-100/CT-150transducersare
ratedatamaximumbipolarprimary
currentof100A/150Awitha
transformaHonraHoof1:1000/1:1500.
GalvanicisolaHonbetweentheprimary
andthesecondarycircuitsallowsto
measurecurrentsatadifferentpotenHal
andsimplifiesinterfacingwhenusing
the0-FLUCSasthefeedbackelement
ofcurrentregulatedpowersupplies.
Outputfromthe0-FLUCStransducers
canbechosenbetweentwodifferent
versions:secondarycurrentoutput
orbufferedvoltageoutput(low
temperaturecoefficientshuntresistor
andlow-noiseamplifierareembedded
inthedevice).
AlsoconnecHontypecanbechosen
betweenthe“C”opHon–amaleDB-9
Connector–andthe“P”opHon–7-pin
through-holeforPCBmounHng.
MaincharacterisHcsofthe0-FLUCS
currenttransformersarenegligible
temperaturecoefficientonthe
secondaryoutputcurrent,excellent
linearityandextremelylownoise.
DCcurrenttransformersrepresentsthe
idealreplacementforsystemswhere
Hall-effectsensorsareusedascurrent
sensingelementsandbe|er
performancesareneeded.
AllCT-100/CT-150devicesalsohave
differentmounHngholesinordertobe
easilyinstalledindifferentconfiguraHons.
Bothself-threadingscrewsandnormal
Onescanbeused.
MainapplicaHonfieldsforthesecurrent
transducersarepreciseandextremely
stableregulatedpowersuppliesand
powerinverters.
C
DuetotheexcellentcharacterisHcs,
the0-FLUCStransducerscanbeused
Commerciallyavailableversionsof
inavarietyofcalibraHon,acceptance
areDB-9connector“C”and7-pin
tesHngandqualitycontrolapplicaHons
striptype“P”withtheirrespecHve
AboutUs
inindustrial,powergeneraHonand
voltage-outputversions“V”.
CAENELSisaleadingcompanyinthedesign
automoHvefields.
ofpowersuppliesandstate-of-the-art
completeelectronicsystemsforthePhysics
theCT-100/CT-150currentsensors
researchworld,havingitsmainfocuson
TechnicalSpecificaJons
dedicatedsoluJonsfortheparJcle
CurrentTransformRaHo–N
1:1000
1:1500
MaximumDCPrimaryCurrent-IP(DC)
±100A
±150A
acceleratorcommunityandhigh-end
industrialapplicaJons.
CT-100
MaximumRMSPrimaryCurrent-IP(RMS)
71A
106A
CurrentPolarity
Bipolar
• 
PowerSupplySystems
MaximumDCSecondaryCurrent-IS(DC)
• 
PrecisionCurrentMeasurements
MaximumRMSSecondaryCurrent-IS(RMS)
• 
BeamlineElectronicInstrumentaJon
• 
FMC&MTCA.4–MicroTCAforPhysics
±100mA
71mA
>500kHz
>200kHz(“V”-version)
SmallSignalBandwidth(±3dB)-BW
<0.5ppm(@200Hz)
<5ppm(@50kHz)
Noise(RMS)–typ.
ExternalShuntResistance(currentoutputonly)-RS
CAENELSd.o.o.
CT-150
<1.5ppm(@200Hz)
<8ppm(@50kHz)
0Ω–40Ω
OutputVoltage(“V”-version)-VOUT
±10V
Kraškaulica,2
6210–Sežana
Slovenija
OutputVoltageRaHo(“V”version)–VOUT/IP(DC)
Phone+386(0)57313585
Fax+386(0)57313587
TemperatureCoefficient–TC(typ.)
<0.5ppm/K
<2ppm/K(“V”-version)
Linearity
<5ppm
<15ppm(“V”-version)
[email protected]
www.caenels.com
InducHonintoPrimary(typ.)
0.1V/A
MaximumOutputCurrent–“V”-version
35µV(RMS)
ProtecHonSignal
Yes-PrimaryOver-Current
SupplyVoltage(±6%)
www.caenels.com
(1/15)V/A
±15mA
±15V
DB-9Connector(“C”)
or
7-pintype(“P”)
ConnecHons
Mechanical(Outer)Dimensions
45×57×75mm
PrimaryConductorHoleDiameter–Ø
16mm
OperaHngTemperatueRange
0…+50°C
MaximumWeight
250g
PS1215I–PS1215V
Low-NoisePowerSupplies
forcurrenttransducers
<!
CT-100/CT-150
7-pinstripconnectorforPCB
0-FLUCS Closed–Loop Technology
The CT-100 and CT-150 current transducer series is based
on the CAEN ELS 0-FLUCS Closed-Loop Technology.
C
OrderingOpJons
WCT100CXAAAA
CT-100-C
100APrimaryCurrent0-FLUCS,DB-9connector
WCT100PXAAAA
CT-100-P
100APrimaryCurrent0-FLUCS,7-pintypeconnecHons
WCT100VCXAAA
CT-100V-C
100APrimaryCurrent0-FLUCS,DB-9connector,Voltage-Output
WCT100VPXAAA
CT-100V-P
100APrimaryCurrent0-FLUCS,7-pintypeconnecHons,Voltage-Output
WCT150CXAAAA
CT-150-C
150APrimaryCurrent0-FLUCS,DB-9connector
WCT150PXAAAA
CT-150-P
150APrimaryCurrent0-FLUCS,7-pintypeconnecHons
WCT150VCXAAA
CT-150V-C
150APrimaryCurrent0-FLUCS,DB-9connector,Voltage-Output
WCT150VPXAAA
CT-150V-P
150APrimaryCurrent0-FLUCS,7-pintypeconnecHons,Voltage-Output
Copyright©CAENELSd.o.o.–2015
Allrightsreserved.InformaHoninthispublicaHonsupersedesallearlierversions.
SpecificaHonssubjecttochangewithoutnoHce.
Rev1.0–PrintedinOctober2015.
!
<
Thefollowingtablesummarizesdataandcharacteris6csofthe<currenttransducerstandardmodels:
Model
Maximum
DC
Primary
Current
Current
Transformer
Ratio - N
±13 A
1:250
CT-13
Bandwidth
(3 dB) – BW
>500 kHz
CT-13V
>200 kHz
CT-26
>500 kHz
±26 A
1:500
CT-26V
>200 kHz
CT-52
>500 kHz
±52 A
1:1000
CT-52V
>200 kHz
CT-100
>500 kHz
±100 A
1:1000
CT-100V
>200 kHz
CT-150
>300 kHz
±150 A
1:1500
CT-150V
>200 kHz
Equivalent Input Noise
<1 ppm @ BW = 200 Hz
<10 ppm @ BW = 50 kHz
<1 ppm @ BW = 200 Hz
<10 ppm @ BW = 50 kHz
<1 ppm @ BW = 200 Hz
<10 ppm @ BW = 50 kHz
<1 ppm @ BW = 200 Hz
<10 ppm @ BW = 50 kHz
<1 ppm @ BW = 200 Hz
<10 ppm @ BW = 50 kHz
Output Type
Current
Voltage
Max DC
secondary
current / Max
voltage output
< 0.5 ppm/K
✔
✗
±52 mA
typ. < 2 ppm/K
✗
✔
< 0.5 ppm/K
✔
✗
Temperature
Coefficient - TC
Max external
Shunt
Resistor
Supply
Voltage
Mounting
PCB
Panel
40 Ω
✔
✗
±10.4 V
n/a
✔
✗
±52 mA
40 Ω
✔
✗
.!
typ. < 2 ppm/K
✗
✔
±10.4 V
n/a
✔
< 0.5 ppm/K
✔
✗
±52 mA
40 Ω
✔
typ. < 2 ppm/K
✗
✔
±10.4 V
n/a
✔
< 0.5 ppm/K
✔
✗
±100 mA
40 Ω
✔
✔
typ. < 2 ppm/K
✗
✔
±10V
n/a
✔
✔
< 0.5 ppm/K
✔
✗
±100 mA
48 Ω
typ. < 2 ppm/K
✗
✔
±10V
n/a
Primary
Conductor
Hole
Diameter
Mechanical
Dimensions
Internal
66 x 64 x
48 mm
16 mm
45 x 57 x
75 mm
✗
✗
✗
✔
✔
✔
✔
±15 V
CT-200
±200 A
1:1000
>100 kHz
CT-200V
CT-300
±300 A
1:1500
>100 kHz
CT-300V
CT-400
±400 A
1:2000
>100 kHz
CT-400V
CT-600
±600 A
1:1500
>150 kHz
CT-1000
CT-1000V
C
1:2000
<10 ppm @ BW = 50 kHz
<1.5 ppm @ BW = 200 Hz
<10 ppm @ BW = 50 kHz
<1.5 ppm @ BW = 200 Hz
<10 ppm @ BW = 50 kHz
<1.5 ppm @ BW = 200 Hz
<10 ppm @ BW = 50 kHz
CT-600V
±1000 A
<1.5 ppm @ BW = 200 Hz
>150 kHz
<1.5 ppm @ BW = 200 Hz
<10 ppm @ BW = 50 kHz
< 0.5 ppm/K
✔
typ. < 2 ppm/K
Temperature
Range
0°C – 50°C
✗
±200 mA
40 Ω
✗
✔
✗
✔
±10V
n/a
✗
✔
< 0.5 ppm/K
✔
✗
±200 mA
30 Ω
✗
✔
typ. < 2 ppm/K
✗
✔
±10V
n/a
✗
✔
< 0.5 ppm/K
✔
✗
±200 mA
25 Ω
✗
✔
typ. < 2 ppm/K
✗
✔
±10V
n/a
✗
✔
< 0.5 ppm/K
✔
✗
±400 mA
30 Ω
✗
✔
typ. < 2 ppm/K
✗
✔
±10V
n/a
✗
✔
< 0.5 ppm/K
✔
✗
±500 mA
20 Ω
✗
✔
typ. < 2 ppm/K
✗
✔
±10V
n/a
✗
✔
94 x 91 x
50 mm
30.7 mm
107 x 91 x
50 mm
Copyright©CAENELSd.o.o.–2015
Allrightsreserved.Informa6oninthispublica6onsupersedesallearlierversions.
Specifica6onssubjecttochangewithoutno6ce.
Rev1.0–PrintedinOctober2015.
PRECISION CURRENT TRANSDUCERS
!
-Selec'onTable
C
<
ProductOverview
CT-200
CT-300
CT-400
PrecisionCurrent
Transducers
!
Currentor
Voltage
Output
CT-200/CT-300/CT-400
●Closed-loopcurrenttransformertechnologyallowsaccuratemonitoringofDCandAC
bipolarcurrentsupto±200A(CT-200),±300A(CT-300)or±400A(CT-400).
●GalvanicisolaJonbetweenprimaryandsecondaryconductorforsimplecurrentsensingat
differentpotenJal.
●Standardcurrentoutputandvoltageoutput(“V”-version)available.
FEATURES
•MonitoringofDCandACcurrents
•ExcellentLinearity
•Closed-loopdetecHon
•Galvanicallyisolatedfromprimary
•LowTemperatureDrie
The0-FLUCS(0-FLUxCurrentSensor)
familyisbasedonaclosedloop
technologythatallowsaccurateand
precisemonitoringofDCandAC
currentswithhighbandwidth.
TheCT-200/CT-300/CT-400transducers
•WideBandwidth
areratedatamaximumbipolarprimary
currentof200A/300A/400Awitha
transformraHoofrespecHvely1:1000,
•HighAccuracy
1:1500and1:2000.
•UL94V-0flammabilitygrade
•LEDindicatescorrectoperaHon
GalvanicisolaHonbetweentheprimary
•DB-9Connectorforrack/panelmounHng
andthesecondarycircuitsallowsto
measurecurrentsatadifferentpotenHal
andsimplifiesinterfacingwhenusing
•Current-outputorVoltage-output
versions
APPLICATIONS
•PowerSupplies
•SensingElementinCalibraHonSystems
•BiomedicalDevices
•NuclearMagneHcResonance(NMR)
•Test&MeasurementSetups
the0-FLUCSasthefeedbackelementof
currentregulatedpowersupplies.
Outputfromthe0-FLUCStransducers
canbechosenbetweentwodifferent
versions:secondarycurrentoutputor
bufferedvoltageoutput(lowTCshunt
resistorandlow-noiseamplifierare
embeddedinthedevice).
AstandardDB-9connectorisusedfor
thetransducerconnecHons.
MaincharacterisHcsofthe0-FLUCS
currenttransformersarenegligible
temperaturecoefficientonthe
secondaryoutputcurrent,excellent
linearityandextremelylownoise.
DCcurrenttransformersrepresentsthe
idealreplacementforsystemswhere
Hall-effectsensorsareusedascurrent
sensingelementsandbe|er
performancesareneeded.
AllCT-200/CT-300/CT-400devices
alsohavedifferentmounHngholesin
ordertobeeasilyinstalledindifferent
configuraHons.Bothself-threadingscrews
andnormalonescanbeused.
MainapplicaHonfieldsforthesecurrent
transducersarepreciseandextremely
stableregulatedpowersuppliesand
powerinverters.
DuetotheexcellentcharacterisHcs,the0FLUCStransducerscanbeusedina
varietyofcalibraHon,acceptance
C
AboutUs
CAENELSisaleadingcompanyinthedesign
tesHngandqualitycontrolapplicaHons
inindustrial,powergeneraHonand
automoHvefields.
Commerciallyavailableversionsofthe
CT-200/CT-300/CT-400current
transformersarethestandard
current-outputandthevoltage-output
“V”version.
DifferentoutputvoltageraHngs–e.g.
±2.5Vor±5V–areavailableupon
requestforaminimumquanHty
ofpowersuppliesandstate-of-the-art
completeelectronicsystemsforthePhysics
CT-200
CT-300
CT-400
dedicatedsoluJonsfortheparJcle
CurrentTransformRaHo-N
1:1000
1:1500
1:2000
acceleratorcommunityandhigh-end
MaximumDCPrimaryCurrent-IP(DC)
±200A
±300A
±400A
MaximumRMSPrimaryCurrent-IP(RMS)
141A
212A
283A
researchworld,havingitsmainfocuson
industrialapplicaJons.
TechnicalSpecificaJons
CurrentPolarity
Bipolar
• 
PowerSupplySystems
MaximumDCSecondaryCurrent-IS(DC)
±200mA
• 
PrecisionCurrentMeasurements
MaximumRMSSecondaryCurrent-IS(RMS)
141mA
• 
BeamlineElectronicInstrumentaJon
ExternalShuntResistorValue–RS
0…40Ω
0…30Ω
0…20Ω
FMC&MTCA.4–MicroTCAforPhysics
SmallSignalBandwidth–typ.BW
>200kHz
>200kHz
>200kHz
• 
SmallSignalBandwidth–“V”version–typ.BW
CAENELSd.o.o.
Noise(RMS)–typ.
100kHz
150kHz
150kHz
<1.5ppm(@200Hz)
<6ppm(@50kHz)
<1.8ppm(@200Hz)
<7ppm(@50kHz)
<2ppm(@200Hz)
<8ppm(@50kHz)
0.05V/A
(1/30)V/A
Kraškaulica,2
6210–Sežana
Slovenija
Phone+386(0)57313585
Fax+386(0)57313587
[email protected]
www.caenels.com
OutputVoltage(“V”-version)-VOUT
±10V
OutputVoltageRaHo(“V”version)–VOUT/IP(DC)
MaximumOutputCurrent–“V”-version
±15mA
<0.5ppm/K
<2ppm/K(“V”-version)
TemperatureCoefficient–TC(typ.)
InducHonintoPrimary(typ.)
5µV(RMS)
Offset(withfactorytrimming)
<10ppm/FS
ProtecHonSignal
Yes-PrimaryOver-Current
SupplyVoltage(±6%)
www.caenels.com
0.025V/A
±15V
MaximumCurrentConsumpHon
50mA+IS
ConnecHons
DB-9Connector
Mechanical(Outer)Dimensions
94×91×50mm
PrimaryConductorHoleDiameter–Ø
30mm
MaximumWeight
380g
PS1215I–PS1215V
Low-NoisePowerSupplies
forcurrenttransducers
<!
StatusLEDandsignal
0-FLUCS Closed–Loop Technology
The CT-200, CT-300 and CT-400 models are based on the
CAEN ELS 0-FLUCS Closed-Loop Technology.
OrderingOpJons
C
WCT200CXAAAA
CT-200
200APrimaryCurrent0-FLUCS,DB-9connector
WCT200VCXAAA
CT-200V
200APrimaryCurrent0-FLUCS,DB-9connector,Voltage-Output
WCT300CXAAAA
CT-300
300APrimaryCurrent0-FLUCS,DB-9connector
WCT300VCXAAA
CT-300V
300APrimaryCurrent0-FLUCS,DB-9connector,Voltage-Output
WCT400CXAAAA
CT-400
400APrimaryCurrent0-FLUCS,DB-9connector
WCT400VCXAAA
CT-400V
400APrimaryCurrent0-FLUCS,DB-9connector,Voltage-Output
Copyright©CAENELSd.o.o.–2015
Allrightsreserved.InformaHoninthispublicaHonsupersedesallearlierversions.
SpecificaHonssubjecttochangewithoutnoHce.
Rev1.0–PrintedinOctober2015.
C
<
ProductOverview
CT-600
CT-1000
PrecisionCurrent
Transducers
Currentor
Voltage
Output
!
CT-600/CT-1000
●Closed-loopcurrenttransformertechnologyallowsaccuratemonitoringofDCandAC
bipolarcurrentsupto±600A(CT-600)andto±1000A(CT-1000).
●GalvanicisolaJonbetweenprimaryandsecondaryconductorforsimplecurrentsensingat
differentpotenJal.
●Standardcurrentoutputandvoltageoutput(“V”-version)available.
FEATURES
•MonitoringofDCandACcurrents
•ExcellentLinearity
•Closed-loopdetecHon
•Galvanicallyisolatedfromprimary
•LowTemperatureDrie
•Current-outputorVoltage-output
versions
•WideBandwidth
•HighAccuracy
•UL94V-0flammabilitygrade
•LEDindicatescorrectoperaHon
•DB-9Connectorforrack/panelmounHng
APPLICATIONS
•PowerSupplies
•SensingElementinCalibraHonSystems
•BiomedicalDevices
•NuclearMagneHcResonance(NMR)
•Test&MeasurementSetups
The0-FLUCS(O-FLUxCurrentSensor)
familyisbasedonaclosedloop
technologythatallowsaccurateand
precisemonitoringofDCandAC
currentswithhighbandwidth.
TheCT-600andCT-1000transducersare
ratedatamaximumbipolarprimary
currentof600Aand1000Awitha
transformraHoof1:1500and1:2000.
GalvanicisolaHonbetweentheprimary
andthesecondarycircuitsallowsto
measurecurrentsatadifferentpotenHal
andsimplifiesinterfacingwhenusing
the0-FLUCSasthefeedbackelementof
currentregulatedpowersupplies.
Outputfromthetransducerscanbe
chosenbetweentwodifferentversions:
secondarycurrentoutputorbuffered
voltageoutput(lowTCshuntresistor
MaincharacterisHcsofthe0-FLUCS
currenttransformersarenegligible
temperaturecoefficientonthe
secondaryoutputcurrent,excellent
linearityandextremelylownoise.
DCcurrenttransformersrepresentsthe
idealreplacementforsystemswhere
Hall-effectsensorsareusedascurrent
sensingelementsandbe|er
performancesareneeded.
AllCT-600andCT-1000devicesalsohave
differentmounHngholesinordertobe
easilyinstalledindifferentconfiguraHons.
Bothself-threadingscrewsandnormal
onescanbeused.
MainapplicaHonfieldsforthesecurrent
transducersarepreciseandextremely
stableregulatedpowersuppliesand
powerinverters.
andlow-noiseamplifierareembeddedin thedevice).
DuetotheexcellentcharacterisHcs,the
CT-600andCT-1000transducerscanbe
AstandardDB-9connectorisusedfor
usedinavarietyofcalibraHon,
thetransducerconnecHons.
C
AboutUs
CAENELSisaleadingcompanyinthedesign
acceptancetesHngandqualitycontrol
applicaHonsinindustrial,power
generaHonandautomoHvefields.
thestandardcurrent-outputCT-600
andCT-1000andthevoltage-output
versionCT-600VandCT-1000V.
Commerciallyavailableversionsofthe
CT-600andCT-1000currentsensorsare
DifferentoutputvoltageraHngs–e.g.
±2.5Vor±5V–areavailableupon
requestforaminimumquanHty.
ofpowersuppliesandstate-of-the-art
completeelectronicsystemsforthePhysics
CT-600
CT-1000
CurrentTransformRaHo-N
1:1500
1:2000
industrialapplicaJons.
MaximumDCPrimaryCurrent-IP(DC)
±600A
±1000A
MaximumRMSPrimaryCurrent-IP(RMS)
424A
707A
researchworld,havingitsmainfocuson
dedicatedsoluJonsfortheparJcle
acceleratorcommunityandhigh-end
• 
PowerSupplySystems
• 
PrecisionCurrentMeasurements
• 
BeamlineElectronicInstrumentaJon
• 
FMC&MTCA.4–MicroTCAforPhysics
TechnicalSpecificaJons
CurrentPolarity
Bipolar
MaximumDCSecondaryCurrent-IS(DC)
±400mA
±500mA
MaximumRMSSecondaryCurrent-IS(RMS)
283mA
354mA
ExternalShuntResistorValue–RS
0…30Ω
0…20Ω
SmallSignalBandwidth(-1dB)–typ.BW
>150kHz
<1.5ppm(@200Hz)
<7ppm(@50kHz)
Noise(RMS)–typ.
CAENELSd.o.o.
Kraškaulica,2
6210–Sežana
Slovenija
Phone+386(0)57313585
Fax+386(0)57313587
[email protected]
www.caenels.com
OutputVoltage(“V”-version)-VOUT
±10V
OutputVoltageRaHo(“V”version)–VOUT/IP(DC)
(1/60)V/A
MaximumOutputCurrent–“V”-version
0.01V/A
±15mA
<0.5ppm/K
<2ppm/K(“V”-version)
TemperatureCoefficient–TC(typ.)
InducHonintoPrimary(typ.)
5µV(RMS)
Offset(withfactorytrimming)
10µV(RMS)
<10ppm/FS
ProtecHonSignal
Yes-PrimaryOver-Current
SupplyVoltage(±6%)
±15V
MaximumCurrentConsumpHon
www.caenels.com
<1.5ppm(@200Hz)
<10ppm(@50kHz)
50mA+IS
ConnecHons
DB-9Connector
Mechanical(Outer)Dimensions
107×91×50mm
PrimaryConductorHoleDiameter–Ø
30mm
MaximumWeight
450g
600g
PS1215I–PS1215V
Low-NoisePowerSupplies
forcurrenttransducers
0-FLUCS Closed–Loop Technology
<!
The CT-200, CT-300 and CT-400 models are based on the
CAEN ELS 0-FLUCS Closed-Loop Technology.
StatusLEDandsignal
OrderingOpJons
C
WCT600CAAAAA
CT-600
600APrimaryCurrent0-FLUCS,DB-9connector
WCT600VXAAAA
CT-600V
600APrimaryCurrent0-FLUCS,DB-9connector,Voltage-Output
WCT1000XAAAA
CT-1000
1000APrimaryCurrent0-FLUCS,DB-9connector
WCT1000VXAAA
CT-1000V
1000APrimaryCurrent0-FLUCS,DB-9connector,Voltage-Output
Copyright©CAENELSd.o.o.–2015
Allrightsreserved.InformaHoninthispublicaHonsupersedesallearlierversions.
SpecificaHonssubjecttochangewithoutnoHce.
Rev1.0–PrintedinOctober2015.
C
ProductOverview
PrecisionCurrent
Transducers
<
PS1215I
PS1215V
Low-Noise
PowerSupplyfor
CurrentTransducers
!
PS1215
●LowNoiseMixedBipolarAC/DCPowerSupplyforopJmaloperaJonofthe<
CurrentTransducers.
●ExtendedInputRangeforVoltageandFrequency.
●“I”and“V”versionsincludecablesforCurrentandVoltageOutputTransducers
respecJvely.
FEATURES
•MixedSwitching/LinearTopology
•27WBipolarOutput-±15V
•LowNoise
•ExtendedACInputRange
•Current-outputorVoltage-output
versionswithcables
•LEDsindicatecorrectoperaHon
•Three-polescrewlockingconnector
APPLICATIONS
•PowerSupplyfor<Transducers
•BipolarSupplyforPreciseInstrumentaHon
•Test&MeasurementSetups
ThePS1215isasingle-output,dualvoltagemixedswitching-linearpower
supplythatisdesignedinordertoobtain
low-noiseoperaHonandhighefficiency
anditisespeciallysuitedforopHmal
performancesofcurrentmeasurement
systemswhereswitchingpowersupplies
couldcorruptthemeasurewithnoise,
lessaccuracyandlessprecision.
Thepowersupplyishousedinarobust
andcompactstainlesssteelboxthatcan
beplacedclosetothesupplieddevicein
ordertoreducecablelengthsand
minimizeconsequentpossiblenoise
pick-up.
ThesepowersuppliesareparHcularly
designedforoperaHonwithCAENELS
DCCurrentTransducers(DCCT)ofthe
<series.
ThePS1215powersupplyhasanoutput
voltageaccuracyof±3%onbothits
posiHveandnegaHveoutputs.
Maximumpeak-to-peakvoltagenoise
measuredatthedeviceoutputterminals
isratedat4mV(measuredatfullload).
OutputDCvoltagesaremadeavailable
througha3-poleconnectorwithascrew
lockingthatallowssecuringthe
connecHon.
ThePS1215powersupplycanbeordered
inthreedifferentversions,differingby
theoutputcabling.
ThePS1215Iversionalsoincludesthe
DB-9connectorandtwo“banana”-type
plugsforthecurrentoutputofstandard
transducers,thePS1215Vversion
includesthesamecablingwithBNC
coaxialconnectorforvoltage-output
ones.
C
AboutUs
TechnicalSpecificaJons
PS1215
OutputPosiHveVoltage(±3%)
+15V
OutputNegaHveVoltage(±3%)
-15V
MaximumOutputPower
27W
MaximumOutputCurrent
+15V@900mA
-15V@900mA
OutputRipple+Noise
0.003%RMS@DC-1MHz
0.025%PEAK-PEAK@DC-1MHz
ACLineVoltageInput
90–260VAC
ACLineFrequency
47-63Hz
InputtoOutputIsolaHon
3kV
CAENELSisaleadingcompanyinthedesign
ofpowersuppliesandstate-of-the-art
completeelectronicsystemsforthePhysics
researchworld,havingitsmainfocuson
dedicatedsoluJonsfortheparJcle
acceleratorcommunityandhigh-end
industrialapplicaJons.
OutputtoEarth-CaseIsolaHon
500V
• 
PowerSupplySystems
Hold-upHme
16ms(typ.)at115VAC
• 
PrecisionCurrentMeasurements
• 
BeamlineElectronicInstrumentaJon
• 
FMC&MTCA.4–MicroTCAforPhysics
CAENELSd.o.o.
Kraškaulica,2
6210–Sežana
Slovenija
Cooling
NaturalconvecHon
Dimensions
136.4×41×90.7mm
Weight
600g
Y-Cablelength(CT-IandCT-V)
3m
Indicators
2LEDs
ProtecHons
Outputshort-circuit
Outputover-voltage
OperaHngTemperatureRange
0°C–50°C
Phone+386(0)57313585
Fax+386(0)57313587
PS1215V
AC-DCPowerSupplyandcablesfor
Voltage-OutputCurrentTransducers
[email protected]
www.caenels.com
www.caenels.com
0-FLUCS Closed–Loop Technology
The PS1215 models are designed for optimal operation for
PS1215I
the CAEN ELS 0-FLUCS current transducers.
AC-DCPowerSupplyandcablesfor
Current-OutputCurrentTransducers
OrderingOpJons
WPS1215XAAAA
PS1215
PS1215-AC/DCSingleOutput-DualVoltage±15VLowNoisePowerSupply-27Wmax-3mcable
WPS1215IXAAA
PS1215I
PS1215-AC/DCSingleOutput-DualVoltage±15VLowNoisePowerSupply-27Wmax+Y-CableCT-I:3mcablewithDB-9and“banana”plugs(currentoutput)
WPS1215VXAAA
PS1215V
PS1215-AC/DCSingleOutput-DualVoltage±15VLowNoisePowerSupply-27Wmax+Y-CableCT-V:3mcablewithDB-9andBNC(voltageoutput)
C
Copyright©CAENELSd.o.o.–2015
Allrightsreserved.InformaHoninthispublicaHonsupersedesallearlierversions.
SpecificaHonssubjecttochangewithoutnoHce.
Rev1.0–PrintedinOctober2015.
FrequencyResponse
PrecisionCurrent
Transducers
<
ACPerformances
●CT-150AmplitudeandPhaseResponse
!
2.0
Amplitude[dB]
1.5
1.0
AmplitudeResponse
0.5
0.0
-0.5 1
10
100
1000
10000
100000
-1.0
Frequency
Amplitude
DC…50kHz
<0.02dB
50…200kHz
<0.5dB
200…400kHz
<1dB
-1.5
-2.0
5
Phase[deg]
0
-5
1
10
100
1000
10000
100000
PhaseResponse
-10
-15
-20
Frequency
PhaseShik
DC…2kHz
<0.1°
2Hz…40kHz
<0.5°
40…400kHz
<2°
-25
-30
Frequency[Hz]
MaximumCurrentRaJngs
AbsoluteRaJngs
●AbsoluteMaximumRaJngsforSingle-PulsePrimaryCurrentOverload
Model
ConJnuous*
for10s
for1s
For0.1s
±78A
CT-13
±14A
±16A
±26A
CT-13V
±13.5A
±16A
±26A
±65A
CT-26
±28A
±32A
±52A
±156A
CT-26V
±27A
±32A
±52A
±130A
CT-52
±52A
±62A
±104A
±208A
CT-52V
±52A
±62A
±104A
±208A
CT-100
±105A
±125A
±200A
±600A
CT-100V
±105A
±125A
±200A
±500A
CT-150
±157A
±180A
±300A
±900A
CT-150V
±155A
±180A
±300A
±750A
CT-200
±210A
±250A
±400A
±1200A
CT-200V
±205A
±250A
±400A
±1000A
CT-300
±315A
±360A
±600A
±1800A
CT-300V
±310A
±360A
±600A
±1500A
CT-400
±420A
±480A
±800A
±2400A
CT-400V
±410A
±480A
±800A
±2000A
CT-600
±630A
±720A
±1200A
±3600A
CT-600V
±620A
±720A
±1200A
±3000A
CT-1000
±1020A
±1200A
±2000A
±5000A
CT-1000V
±1010A
±1200A
±2000A
±5000A
*SpecificaHonsovertheratedcurrentsarenotguaranteed
<
C
Precision Current
Measurements
CAEN ELS d.o.o.
kraška ulica 2
6210 – Sežana
Slovenija
www.caenels.com
[email protected]