Product Overview
CT-150
DC Current Transformer Series
Current or Voltage Output
Closed-loop current transformer technology allows accurate monitoring of DC and AC
bipolar currents up to ±150A.
Galvanic isolation between primary and secondary conductor for simple current
sensing at different potential.
Standard current output and voltage output (“V”-version) available.
Features
The O-FLUCS (O-FLUx Current Sensor)
between the “C” option – a male DB-9
family is based on a closed loop
Connector – and the “P” option – 6-pin
• Monitoring of DC and AC currents
technology that allows accurate and
through-hole for PCB mounting.
• Excellent Linearity
precise monitoring of DC and AC
• Closed-loop detection
currents with high bandwidth.
• Galvanically isolated from primary
• Low Temperature Drift
The CT-150 transducers are rated at a
• Current-output or Voltage-output
at maximum bipolar primary current
versions
• Wide Bandwidth
• High Accuracy
• LED indicates correct operation
• DB-9 Connector or PCB-mount versions
of 150A with a transformation ratio of
1:1000.
Galvanic isolation between the primary
and the secondary circuits allows to
measure currents at a different potential
and simplifies interfacing when using
Applications
• Power Supplies
• Sensing Element in Calibration Systems
• Biomedical Devices
• Nuclear Magnetic Resonance (NMR)
the O-FLUCS as the feedback element
of current regulated power supplies.
Output from the CT-150 transducers
Main characteristics of the O-FLUCS
current transformers are negligible
temperature coefficient on the
secondary output current, excellent
linearity and extremely low noise.
DC current transformers represents the
ideal replacement for systems where
Hall-effect sensors are used as current
sensing elements and better
performances are needed.
All CT-150 devices also have different
mounting holes in order to be easily
can be chosen between two different
installed in different configurations. Both
versions: secondary current output or
self-threading screws and normal ones
buffered voltage output (low
can be used.
temperature coefficient shunt resistor
and low-noise amplifier are embedded
Main application fields for these current
in the device).
transducers are precise and extremely
stable regulated power supplies and
Also connection type can be chosen
power inverters.
Due to the excellent characteristics, the
Commercially available versions of
CT-150 transducers can be used
The CT-150 current transformers are
in a variety of calibration, acceptance
the current-output CT-150-C and
testing and quality control applications
CT-150-P with their respective voltage-
in industrial, power generation and
output versions CT-150V-C and
automotive fields.
CT-150V-P.
Technical Specifications
CT-150
About CAENels
CAENels is a dynamic company that
Current Transform Ratio - N
1:1000
provides power supplies and state-of-the-art
Maximum DC Primary Current - IP(DC)
±150 A
dedicated electronic systems to the particle
Maximum RMS Primary Current - IP(RMS)
accelerator community – e.g. synchrotron
light sources and Free Electron Laser (FEL)
facilities.
•
Magnet Power Supply Systems
106 A
Current Polarity
Bipolar
Maximum DC Secondary Current - IS(DC)
±150 mA
Maximum RMS Secondary Current - IS(RMS)
106 mA
Small Signal Bandwidth ( ±1 dB ) - BW
> 100 kHz
Noise (DC-10 kHz) – typ.
5 ppm (RMS)
•
Beamline Electronic Instrumentation
•
Precision Current Transducers
Output Voltage Ratio (“V” version) – VOUT/IP(DC)
•
High-Voltage Dedicated Systems
Maximum Output Current – “V”-version
Output Voltage (“V”-version) - VOUT
Temperature Coefficient – TC (typ.)
±10 V
(1/15) V/A
±15 mA
< 0.5 ppm/K
< 2 ppm/K (“V”-version)
Induction into Primary (typ.)
Protection Signal
CAEN els d.o.o.
35 µV (RMS)
Yes - Primary Over-Current
Supply Voltage (± 6%)
±15 V
Kraška ulica, 2
6210 – Sežana
Slovenija
Connections
Phone +386 (0)5 7313 585
Fax +386 (0)5 7313 587
Mechanical (Outer) Dimensions
[email protected]
Primary Conductor Hole Diameter – Ø
DB-9 Connector (“C”)
or
6-pin type (“P”)
45 × 57 × 75 mm
16 mm
Maximum Weight
400 g
www.caenels.com
O-FLUCS – CT-150 Rear View
Ordering Options
WCT150CXAAAA
CT-150-C
150 A Primary Current O-FLUCS , DB-9 connector
WCT150PXAAAA
CT-150-P
150 A Primary Current O-FLUCS , 6-pin type connections
WCT150VCXAAA
CT-150V-C
150 A Primary Current O-FLUCS , DB-9 connector, Voltage-Output
WCT150VPXAAA
CT-150V-P
150 A Primary Current O-FLUCS , 6-pin type connections, Voltage-Output