MA-COM MD

High Performance Double-Balanced
Mixer, 5 - 1000 MHz
MD-113
V 3.00
Features
FP-2
Low Cost Flatpack
Conversion Loss: 7 dB Typical
Impedance: 50 Ohms Nominal
Maximum Input Power: 300 mW max. @ 25°C,
Derated linearly to 85°C @ 3.2 mW/°C
n IF Port Current: 50 mA Max.
n MIL-STD-883 Screening Available
n
n
n
n
Description
Transformers convert the LO and RF paths to balanced
lines connecting to a low barrier, Schottky diode ring quad.
These transformers help provide excellent isolation between
ports. Conversion Loss is low. The direct connection of
the IF port to the diode quad allows these mixers to be used
as phase detectors and bi-phase modulators.
Pin Configuration
Pin No.
Function
Pin No.
Function
1
GND
5
LO
2
GND
6
GND
3
GND
7
GND
4
IF
8
RF
Electrical Specifications1: TA = -55°C to +85°C
Parameter
Test Conditions
Frequency
Units
Min
Typ
Max
Frequency Range
RF, LO Ports
IF Port
5 - 1000
DC - 1000
MHz
MHz
—
—
—
—
—
—
5 - 50 MHz
50 - 500 MHz
500 - 1000 MHz
dB
dB
dB
—
—
—
—
—
—
7.5
7.5
8.0
LO to RF
5 - 50 MHz
50 - 500 MHz
500 - 1000 MHz
dB
dB
dB
35
30
25
—
—
—
—
—
—
LO to IF
5 - 50 MHz
50 - 500 MHz
500 - 1000 MHz
dB
dB
dB
30
25
20
—
—
—
—
—
—
RF to IF
5 - 50 MHz
50 - 500 MHz
500 - 1000 MHz
dB
dB
dB
25
20
15
—
—
—
—
—
—
Negative
—
—
—
—
—
mV
—
<2
—
dBm
dBm
—
—
0
-2
—
—
Conversion Loss
Isolation
DC Polarity
DC Offset
RF Input
1 dB Compression
1 dB Desensitization
1. All specifications apply when operated at +7 dBm available LO power with 50 ohm source and load impedance.
High Performance Double-Balanced Mixer, 5 - 1000 MHz
MD-113
V 3.00
Electrical Specifications: TA = -55°C to +85°C
Parameter
Test Conditions
Frequency
Units
Min
Typ
Max
SSB Noise Figure
Within 1 dB of Conversion Loss
Max.
—
—
—
—
—
Typical Two Tone IM
Ratio
With –10 dBm input, each input 25
MHz and 35 MHz IF
100 - 550 MHz
550 - 800 MHz
800 - 1000 MHz
dB
dB
dB
—
—
—
>47
>38
>44
—
—
—
Typical Performance Curves
Isolation
Conversion Loss (RF = -5 dBm,
LO = +7 dBm)
LO - RF
LO - IF
RF - IF
50
Isolation (dB)
Conversion Loss (dB)
8
7
6
40
30
20
5
10
20
50
100
200
500
1000
5
10
20
Frequency (MHz)
50
100
200
500
1000
Frequency (MHz)
Conversion Loss vs. LO Power
(LO = 1.060 GHz, RF = 1.000 GHz
@ -10 dBm)
Ordering Information
10
Part Number
Package
MD-113 PIN
FP-2
Loss (dB)
9
8
7
6
0
5
10
15
20
LO Power (dBm)
Specifications subject to change without notice.
n North America: Tel. (800) 366-2266
n Asia/Pacific: Tel.+81-44-844-8296, Fax +81-44-844-8298
n Europe: Tel. +44 (1344) 869 595, Fax+44 (1344) 300 020
Visit www.macom.com for additional data sheets and product information.