High Performance Double-Balanced Mixer, 5 - 1000 MHz MD-113 V 3.00 Features FP-2 Low Cost Flatpack Conversion Loss: 7 dB Typical Impedance: 50 Ohms Nominal Maximum Input Power: 300 mW max. @ 25°C, Derated linearly to 85°C @ 3.2 mW/°C n IF Port Current: 50 mA Max. n MIL-STD-883 Screening Available n n n n Description Transformers convert the LO and RF paths to balanced lines connecting to a low barrier, Schottky diode ring quad. These transformers help provide excellent isolation between ports. Conversion Loss is low. The direct connection of the IF port to the diode quad allows these mixers to be used as phase detectors and bi-phase modulators. Pin Configuration Pin No. Function Pin No. Function 1 GND 5 LO 2 GND 6 GND 3 GND 7 GND 4 IF 8 RF Electrical Specifications1: TA = -55°C to +85°C Parameter Test Conditions Frequency Units Min Typ Max Frequency Range RF, LO Ports IF Port 5 - 1000 DC - 1000 MHz MHz — — — — — — 5 - 50 MHz 50 - 500 MHz 500 - 1000 MHz dB dB dB — — — — — — 7.5 7.5 8.0 LO to RF 5 - 50 MHz 50 - 500 MHz 500 - 1000 MHz dB dB dB 35 30 25 — — — — — — LO to IF 5 - 50 MHz 50 - 500 MHz 500 - 1000 MHz dB dB dB 30 25 20 — — — — — — RF to IF 5 - 50 MHz 50 - 500 MHz 500 - 1000 MHz dB dB dB 25 20 15 — — — — — — Negative — — — — — mV — <2 — dBm dBm — — 0 -2 — — Conversion Loss Isolation DC Polarity DC Offset RF Input 1 dB Compression 1 dB Desensitization 1. All specifications apply when operated at +7 dBm available LO power with 50 ohm source and load impedance. High Performance Double-Balanced Mixer, 5 - 1000 MHz MD-113 V 3.00 Electrical Specifications: TA = -55°C to +85°C Parameter Test Conditions Frequency Units Min Typ Max SSB Noise Figure Within 1 dB of Conversion Loss Max. — — — — — Typical Two Tone IM Ratio With –10 dBm input, each input 25 MHz and 35 MHz IF 100 - 550 MHz 550 - 800 MHz 800 - 1000 MHz dB dB dB — — — >47 >38 >44 — — — Typical Performance Curves Isolation Conversion Loss (RF = -5 dBm, LO = +7 dBm) LO - RF LO - IF RF - IF 50 Isolation (dB) Conversion Loss (dB) 8 7 6 40 30 20 5 10 20 50 100 200 500 1000 5 10 20 Frequency (MHz) 50 100 200 500 1000 Frequency (MHz) Conversion Loss vs. LO Power (LO = 1.060 GHz, RF = 1.000 GHz @ -10 dBm) Ordering Information 10 Part Number Package MD-113 PIN FP-2 Loss (dB) 9 8 7 6 0 5 10 15 20 LO Power (dBm) Specifications subject to change without notice. n North America: Tel. (800) 366-2266 n Asia/Pacific: Tel.+81-44-844-8296, Fax +81-44-844-8298 n Europe: Tel. +44 (1344) 869 595, Fax+44 (1344) 300 020 Visit www.macom.com for additional data sheets and product information. 2