Datasheet

G8V
Automotive Micro 280 relay
Micro 280 terminal layout
• Both SPST and SPDT available
• Miniaturized package (reduced outer length and
width)
• L x W x H = 22.5 x 15 x 25.5 mm nominal
• 280-terminal type
• Full automated assembly
■ Type standard
G8V-@@@@-@
➀➁➂➃ ➄
Classification
Symbol
➀
Number of contact poles
1
➁
Contact structure
➂
➃
➄
Meaning of the symbol
Number of contact poles
A
1a contact
C
1c contact
Protective structure
7
Unsealed (In a case)
Terminal form
T
Plug-in type
Surge suppressor
R
Built-in resistor
280 Relay
■ Classification
Classification
Terminal form
Contact structure
280 Micro
Plug-in 280 terminal
SPST (1a)
Protective structure
Unsealed (In a case)
SPDT (1c)
Rated coil
Voltage (V)
Resistance (:)
DC12
85
■ Ratings
● Operation coil
Coil resistance (:)
Rated
voltage
(V)
Between
terminals
Internal coil
Surge
suppressor
resistance
DC12
85
97
1/2W 680
Rated
current
(mA)
Operating
voltage
(V)
Release
voltage
(V)
Service voltage
range
(V)
Rated power
consumption
(mW)
141
8.0 or less
1.0 or more
DC10 to 16
1694
● Switching area
Item
Performance
Contact material
Silver alloy
Rated voltage
Rated load
Inrush current
Continuous carry
current*1
DC12V
N.O. side
Resistance load, 20A
N.C. side
Resistance load, 10A
N.O. side
60A
N.C. side
30A
N.O. side
20A
N.C. side
10A
Min. Carry / Switching Current
DC12V 1A
Please confirm Omron Safety Precautions for all automotive relays first.
Omron can not guarantee automotive relays before finish making a contract with product
specifications.
64
Type
G8V-1A7T-R
G8V-1C7T-R
G8V
Automotive Micro 280 relay
■ Performance
Item
Standard value
Voltage drop
between
terminals
N.O. side
150mV or less, 10A
N.C. side
175mV or less, 10A
Operating time*2
Max. 10ms at 14V (Normally 4ms)
Release time*2
Insulation
resistance*3
Max. 10ms at 14V (Normally 1.8 ms)
Between coil and terminal
20M: or more
Between homopolar contacts
20M: or more
Withstand
voltage*4
Between coil and terminal
AC500V, for 1minute
Between homopolar contacts
AC500V, for 1minute
Vibration
tolerance
Durability
33Hz 43.1m/s2
20 to 500Hz 43.1m/s2
Malfunction
Mechanical endurance
1,000,000 times
Electrical endurance
100,000 times (load dependent)
Ambient temperature
40 to +125qC
Ambient humidity
35 to 95%RH
Weight
Approx. 19.3g
■ Packing
Tray
MOQ*5
480pcs (96pcs×5trays)
All values above are measured in early time under an ambient temperature of +20qC and humidity of 65% unless stated
The value stated is at maximum temperature in a guaranteed ambient temperature.
Bounce time is not included.
Measured at DC500V.
Measured under 1mA of leak current, 50/60Hz for 1minute.
Minimum Order Quantity is subject to change, please feel free to contact our sales representatives.
280 Relay
Note:
*1.
*2.
*3.
*4.
*5.
Packing form
Please confirm Omron Safety Precautions for all automotive relays first.
Omron can not guarantee automotive relays before finish making a contract with product
specifications.
65
G8V
Automotive Micro 280 relay
■ Dimensions (Unit: mm)
G8V-1A7T-R
Terminal arrangement /
Internal connections
(BOTTOM VIEW)
87
85
86
30
Country
of origin
25.5±0.5
11±0.5
2.8±0.15
0.825±0.05
3.90
16.2
22.5±0.5
7.80
15±0.5
87
85
86
30
G8V-1C7T-R
Terminal arrangement /
Internal connections
(BOTTOM VIEW)
87 87a 85
86
30
Country
of origin
25.5±0.5
11±0.5
2.8±0.15
8.1
3.90
280 Relay
16.2
22.5±0.5
87
86
0.825±0.05
87a
7.80
15±0.5
85
30
* Tolerance unless otherwise specified Less than 1 mm: ±0.1 mm
Less than 1 to 3 mm: ±0.2 mm
3 mm or more: ±0.3 mm
Please confirm Omron Safety Precautions for all automotive relays first.
Omron can not guarantee automotive relays before finish making a contract with product
specifications.
66