Application Note 55W Flyback ConverterDesign with IRS2982S controller

ANEVAL_201602_PL16_017
55 W Flyback converter design using the IRS2982S controller
IRXLED04
Authors:
Peter B. Green
About this document
Scope and purpose
The purpose of this document is to provide a comprehensive functional description and guide to using the
IRS2982S control IC for LED and general purpose switch mode power supply (SMPS). The scope applies to all
technical aspects that should be considered in the design process, including calculation of external component
values, MOSFET selection, PCB layout optimization as well as additional circuitry that may be added if needed
in certain cases.
Intended audience
Power supply design engineers, applications engineers, students.
Table of Contents
1
Introduction ....................................................................................................................................... 2
2
IRS2982S functional overview ............................................................................................................ 3
3
3.1
3.2
Flyback converter............................................................................................................................... 4
Flyback converter types .......................................................................................................................... 4
Eval board specifications ........................................................................................................................ 5
4
Schematic .......................................................................................................................................... 6
5
Dimensioning ..................................................................................................................................... 7
6
Control loop ....................................................................................................................................... 9
7
Bill of materials ................................................................................................................................ 11
8
Transformer specification ................................................................................................................ 13
9
9.1
PCB Layout ....................................................................................................................................... 14
PCB layout guidelines for system optimization ................................................................................... 15
10
10.1
10.2
10.3
10.4
10.12
10.12.1
10.12.2
10.12.3
10.13
10.13.1
Test results....................................................................................................................................... 16
Operation at maximum load ................................................................................................................. 16
Test measurements under different line and load conditions ............................................................ 16
Start and steady state operation at maximum load ............................................................................ 21
Light load DCM operation ..................................................................................................................... 31
Thermal Performance under abnormal operating conditions ............................................................ 35
Open feedback loop (RFB1 removed), VCC supply connected ....................................................... 35
VCC supply removed (DVCC2 removed), feedback loop connected ................................................ 36
Reduced VCC supply (Support mode) ............................................................................................. 37
Line current harmonics according to EN61000-3-2 ............................................................................. 38
EMI Conducted Emissions (tested to CISPR22 limits) ..................................................................... 40
11
Conclusion ....................................................................................................................................... 42
Application Note
www.infineon.com
Please read the Important Notice and Warnings at the end of this document
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Introduction
1
Introduction
The IRS2982S is a versatile SMPS controller IC primarily intended for LED drivers in the 5 to 100 W power ranges
suitable for Buck, Buck-Boost and Flyback converters operating in critical conduction mode (CrCM) and
discontinuous mode (DCM) at light loads. Flyback converters will be covered in this application note focusing
on an isolated voltage regulated design with PFC.
All of the control and protection required for the converter is integrated in the IRS2982S as well as a high
voltage start-up cell to enable rapid illumination at switch on over a wide line input voltage range. The
IRS2982S is also able to provide power factor correction in a single stage Flyback converter able to meet class C
(lighting) line current harmonic limits of the EN61000-3-2 standard.
A 55 W isolated voltage regulated PFC Flyback evaluation board based on the IRS2982S controller is described
in detail in this application note and detailed test results are presented.
Figure 1
IRXLED04 55 W Flyback evaluation board
Application Note
2
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
IRS2982S functional overview
2
IRS2982S functional overview
The IRS2982S is comprised of the following functional blocks:
1. High voltage start-up cell
The IC internal functional blocks remain disabled in low power mode until VCC first rises above the
VCCUV+ under-voltage lock out (UVLO) threshold, continuing to operate while VCC remains above VCCUV-.
VCC is initially supplied through the integrated high-voltage start-up cell, which supplies a controlled
current from the HV input provided a voltage greater than VHVSMIN, is present. The current supplied is
limited to IHV_CHARGE reducing to less than IHVS_OFF when VCC reaches the cut-off threshold VHVS_OFF1. The HV
start-up cell switches over from start-up mode to support mode after the feedback input at FB has
exceeded VREG for the first time. In this mode the cut-off threshold becomes VHVS_OFF2. During steady state
operation under all line-load conditions VCC is supplied through an auxiliary winding on the Flyback
transformer with VCC high enough so that the HV start-up in does not supply current. If the auxiliary
supply were unable to maintain VCC, the HV start-up cell operating in support mode would supply
current to assist.
2. PWM controller
The SMPS control section operates in voltage mode where the gate drive output on time is proportional
to the error amplifier output voltage appearing at the compensation output COMP. An external
capacitor CCOMP (shown in figure 3) connected to 0 V (ground) acts with the trans-conductance
characteristic of the error amplifier to provide loop compensation and stability. Minimum on time is
reached when VCOMP falls to VCOMPOFF below which the gate drive is disabled. Under very light load
conditions VCOMP transitions above and below VCOMPOFF to produce burst mode operation. Off time is
determined by the demagnetization signal received at the ZX input, which is derived from the auxiliary
transformer winding that supplies VCC through a resistor divider. Internal logic limits the minimum off
time to tOFFMIN, therefore the system transitions from CrCM to DCM at light loads. If the ZX input signal
fails to provide triggering the next cycle will start automatically after a re-start period of tWD.
3. Protection
The IRS2982S includes cycle by cycle primary over-current protection, which causes the gate drive to
switch off if the voltage detected at the CS exceeds the threshold VCSTH. This prevents the possibility of
transformer saturation at low line under heavy load but does not protect against output overload or
short circuit.
Over-voltage protection is also provided through the ZX input, which provides a voltage proportional to the
output voltage. This disables the gate drive output and pulls the COMP voltage below the VCOMPOFF threshold.
The error amplifier then starts to charge CCOMP until the gate drive starts up again at minimum on time. Under
an open circuit output condition the over voltage protection causes the converter to operate in burst mode
preventing the output voltage from rising too high. The IRS2982S uses an SO-8 package as shown below:
HV
VCC
8
FB
2
COMP
3
IRS2982
1
ZX
4
Figure 2
Application Note
OUT
7
COM
6
CS
5
Pin
1
2
3
4
5
6
7
8
Name
HV
FB
COMP
ZX
CS
COM
OUT
VCC
Description
High Voltage Start-up Input
Feedback Input
Compensation and averaging capacitor input
Zero-Crossing & Over-Voltage Detection input
Current Sensing Input
IC Power & Signal Ground
Gate Driver Output
Logic & Low-Side Gate Driver Supply
IRS2982S pin assignments
3
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Flyback converter
3
Flyback converter
3.1
Flyback converter types
There are several configurations of Flyback converter that may be used with the IRS2982S depending on the
application. These can be classified according to isolation and regulation requirements as follows:
1. Isolated or non-isolated
2. Current or voltage regulation
In the case of voltage regulation current limiting is needed for protection against overload or short circuit and
in the case of current regulation over-voltage protection is necessary for an open-circuit.
The IRS2982S can operate in any of the four combinations of (1) and (2). Extremely accurate current or voltage
regulation is achieved in non-isolated converters since direct feedback to the FB input is possible. Isolation is
however required in the majority of Flyback converters. For isolated constant current regulation an optoisolator is necessary; for isolated constant voltage regulation feedback may be taken from the auxiliary winding
as shown in figure 3 with a small loss of line and load regulation accuracy. An opto-isolator is also necessary for
highly accurate voltage regulation.
The basic circuit in figure 3 shows the main elements of the IRS2982S based PFC Flyback converter. This can be
used as a stand-alone power supply or as a front end stage with a current regulating Buck regulator as the back
end stage in a dimmable (or non-dimmable) off line LED driver. This front end stage is able to provide a
regulated output voltage over a wide range of line and load with sufficient accuracy for the majority of
applications.
DFB
CSN
RSN
RVCC
+VOUT
DVCC
T1
DSN
CIN
RFB1
BR1
HV
IC1
2
COMP
3
ZX
4
IRS2982
FB
AC
Line
Input
VCC
RZX1
8
CVCC
1
DZ
CS
OUT
CVOUT
ROUT
7
COM
6
CS
5
RG
RFB2
CCOMP
M1
RF
RCS
CF
RZX2
CI
Figure 3
-VOUT
Isolated voltage regulated Flyback converter based on the IRS2982S
A 55 W PFC Flyback voltage regulated design as implemented in the IRXLED04 evaluation board will be
discussed in detail in the following sections.
Application Note
4
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Flyback converter
3.2
Eval board specifications
Input and output at normal operation:
 AC Input voltage 100 VAC up to 265 VAC (45 to 65 Hz)
 Output voltage 55 VDC
 Maximum output voltage ripple +/-3 V @ full load
 The tolerance of the nominal output voltage is +/-5% in the power range from 10% up to 100% of the
rated output power.
 Maximum output continuous power 55 W
 PF >0.95 @50 W load and 230 VAC input voltage
 THD <10% @50% up to 100% load and < 20% @ 20% load with 230 VAC input voltage
 Efficiency >89% at 80% load and >88% at 100% load @ 230 VAC input voltage.
 Startup time to reach the secondary nominal output voltage of 55 VDC during full load condition and
230 VAC input voltage must be <300 ms.
Protection features
 Primary output over-voltage protection @ VOUT <= 60 VDC
 Cycle by cycle primary over-current protection
Attention:
Output short circuit and overload protection are not provided on this evaluation board. This board
can be damaged by sustained over loading or short circuiting the output!
No load operation
 Burst mode during no load condition.
 Max power losses during no load condition must be <500 mW @230 VAC input voltage
Max component temperature
During worst case scenario (ambient temperature 60 °C) the max allowed component temperature is:
 Resistor < 105 °C
 Ceramic capacity, film capacity and electrolyte capacity <85 °C
 Flyback Transformer and chokes <105 °C
 MOSFET, transistor and diodes <105 °C
 IC <100 °C
Dimension of evaluation board

Max width 2.2” (55.9 mm), max length 4.4” (111.8 mm).
Safety Requirements
The single stage Flyback converter should cover the safety requirement regarding EN61347-2-13 and SELV max
output voltage 60 VDC. This part of IEC 61347 specifies particular safety requirements for electronic control gear
for use in DC supplies up to 250 V and AC supplies up to 1000 V at 50 Hz or 60 Hz and at an output frequency
which can deviate from the supply frequency, associated with LED modules.
Note:
This evaluation board is designed as a front end stage for a two stage power supply such as an LED
driver where the back end stage is a current regulating Buck regulator. The Flyback converter uses
primary voltage regulation with no secondary current feedback and is therefore not designed to
withstand a sustained overload or short circuit condition. Additional circuitry may be added if such
protection is required.
Application Note
5
Rev 1.1
2016-03-09
3
2
1
ACIN
P1
S10K320E2K1
VR1
1.6A/300VAC
L1
60mH/0.5A
CX1
0.1uF/305V
CY2
1nF/300VAC
1nF/300VAC
0.22uF/305V
CX2
CY1
2
1
F1
3
4
3
1
1
COM2
Black
2
BR1
GBU4J-E3/51
COM1
Black
4
1
6
1
Application Note
RZX2
14k
0.1uF/630V
CDC
10k/0.5W
RHV
Yellow
1
ZX
RZX1
47k
10nF
CFB
CZX
22pF
CCMP1
22nF
Yellow
1
COMP
Output Voltage = 55V
RFB2
20k
Orange
1
FB
RFB1
1M
IRS2982
ZX
COMP
FB
HV
RCMP
330k
CCMP2
0.22uF
4
3
2
1
IC1
RSNB1
470k
CCF
1nF
CS
COM
OUT
VCC
Red
1
VCC
LL4148
DVCC1
5
6
7
8
RSNB2
470k
470
Orange
RCF
1
10
RVCC1
CSNB
1nF/1kV
RCS1
4.7
RG2
10k
RG1 4.7
VCS
RSNB3
470k
RCS2
1.5
RCS3
1.5
MFB
IPA80R650CE
1
White
1
GATE
DSNB
RS1MB
2
3
Figure 4
RCS4
1.5
T1
o
0.1uF
CVCC1
CDS
N/F
4
5
3o
2o
1
o
o
8
7
10
9
12
11
DZ
18V
22uF/25V
+ CVCC2
LL4148
DVCC2
+
10uF
CVB
510
COUT2
+
COUT3
470uF/63V
1nF/300VAC
CY3
470uF/63V
RVCC2
470uF/63V
COUT1
DOUT
SBR20A300CT
+
COUT4
470uF/63V
+
VOUTBlack
ROUT
15k
1
2
P2
OUT+
VOUT+
Red
1
4
1
VDC(HV)
Red
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Schematic
Schematic
IRXLED04 55 W PFC Flyback schematic
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Dimensioning
5
Dimensioning
The IRXLED04 eval board is populated for basic voltage regulation from the transformer auxiliary winding as
shown in figures 3 and 4.
The Flyback converter is designed for power factor correction with low AC line current total harmonic distortion
(iTHD). The MOSFET used is an IPA80R650CE 800 V rated CoolMOS device with 650 mΩ on resistance, 45 nC gate
charge and low parasitic capacitances in a TO-220 FullPAK. This device is able to withstand high voltage ringing
at switch off with minimal added snubber components and has low conduction and switching losses as well
low gate drive current.
The parameters of the MOSFET and output diode contribute to the overall high efficiency of the converter.
The Flyback transformer (more accurately described as a coupled inductor) consists of three windings; the
primary for energy storage during the on time, the secondary for energy transfer to the output during the off
time and the auxiliary, which supplies VCC and provides the required de-magnetization and voltage feedback
signals. The IRS2982S (IC1) VCC supply is derived from the transformer auxiliary winding through DVCC1 initially
charging CVB then CVCC1 and 2 through RVCC and DVCC2 with DZ to clamp the voltage to protect IC1. Voltage
feedback is provided through a divider comprised of RFB1 and RFB2, which sets the output voltage. The
auxiliary winding voltage is proportional to the output voltage so that:
𝑉𝐴𝑈𝑋 = 𝑉𝑅𝐸𝐹 ∙
𝑅𝐹𝐵1+𝑅𝐹𝐵2
𝑅𝐹𝐵2
𝑁
= 𝑉𝑂𝑈𝑇 ∙ 𝑁𝐴
[V]
𝑆
[1]
Switching cycle peak current limiting is set by parallel shunt resistors RCS1 to 4, which give a combined
resistance of 450 mΩ, setting the peak current to 2.67 A according to the threshold VCSTH of 1.2 V. This limits
the inrush current during start-up and also protects against damage under over load or short circuit conditions.
The eval board is not designed to withstand a sustained output overload or short circuit.
The maximum peak current at low line and full load, assuming DMAX is 0.58 is calculated as:
𝐼𝑃𝑀𝐴𝑋 = 𝐷
2√2∙𝑃𝑂𝑈𝑇
𝑀𝐴𝑋 .𝑉𝐴𝐶𝑀𝐼𝑁 ∙𝜂
=
2√2∙50
0.58∙100∙0.9
[A]
= 2.71
[2]
The transformer turns-ratio is calculated as follows:
𝑁=
𝑁𝑃
𝑁𝑆
=
√2∙𝑉𝐴𝐶𝑀𝐼𝑁
𝑉𝑂𝑈𝑇 +𝑉𝐹
𝐷
∙ 1−𝐷𝑀𝐴𝑋 =
𝑀𝐴𝑋
0.58
√2∙100
∙
55+1 1−0.58
[3]
= 3.49
The primary to auxiliary winding turns-ratio is calculated to provide an auxiliary supply voltage of 20 V:
𝑁𝑃
𝑁𝐴
=𝑉
√2∙𝑉𝐴𝐶𝑀𝐼𝑁
𝐴𝑈𝑋 +𝑉𝐹(𝐴𝑈𝑋)
𝐷
∙ 1−𝐷𝑀𝐴𝑋 =
𝑀𝐴𝑋
0.58
√2∙100
∙
20+1 1−0.58
[4]
= 9.3
The transformer primary inductance is calculated according to the formula:
𝐿𝑃𝑅𝐼 =
2
𝑉𝐴𝐶𝑀𝐼𝑁
∙𝜂∙𝑁∙(𝑉𝑂𝑈𝑇 +𝑉𝐹 )
2∙𝑃𝑂𝑈𝑇 ∙𝑓𝑀𝐼𝑁 ∙[𝑁∙(𝑉𝑂𝑈𝑇 +𝑉𝐹 )+√2∙𝑉𝐴𝐶𝑀𝐼𝑁 ]
1002 ∙0.9∙3.49∙(55+1)
2∙50∙65000∙[3.49∙(55+1)+√2∙100 ]
[H]
= 803 ∙ 10−6 H = 803
[5]
[µH]
Where, 𝜂 is the efficiency assumed to be 0.9 and minimum frequency set to 65 kHz to occur at the peak of the
line input voltage at 100 Vrms.
Application Note
7
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Dimensioning
The resistor divider comprising RFB1 and RFB2 sets the output voltage according to:
𝑉𝑂𝑈𝑇 =
𝑁𝑃
𝑁𝐴
1
∙ 𝑁 ∙ 𝑉𝑅𝐸𝐹 ∙
𝑅𝐹𝐵1+𝑅𝐹𝐵2
𝑅𝐹𝐵2
[V]
[6]
In this design, RFB2=20 k and RFB1=1 M. VREF is 400 mV specified in the IRS2982S datasheet therefore:
1
9.3 ∙ 3.49 ∙ 0.4 ∙
20𝑘+1000𝑘
20𝑘
[V]
= 54.4
The threshold for over voltage protection through the ZX input is given by the resistor divider consisting of RZX1
and RZX2, where RZX1=47 k and RZX2=14 k and VOVTH is 5.1 V:
𝑉𝑂𝑈𝑇𝑂𝑉 =
𝑁𝑃
𝑁𝐴
∙
1
9.3 ∙ 3.49 ∙ 5.1 ∙
1
𝑁
∙ 𝑉𝑂𝑉𝑇𝐻 ∙
47𝑘+14𝑘
14𝑘
𝑅𝑍𝑋1+𝑅𝑍𝑋2
𝑅𝑍𝑋2
[V]
[7]
[V]
= 59.2
The maximum reflected voltage appearing at the MOSFET drain is then calculated as follows based on the
highest AC line input voltage of 265 Vac:
𝑉𝐷𝑀𝐴𝑋 = √2 ∙ 𝑉𝐴𝐶𝑀𝐴𝑋 + (𝑉𝑂𝑈𝑇(𝑀𝐴𝑋) + 𝑉𝐹 ) ∙ 𝑁
[V]
√2 ∙ 265 + (60 + 1) ∙ 3.49 = 588
[V]
[8]
It is recommended to allow 30% headroom on top of the reflected voltage to accommodate the switch off
transient and high voltage ringing. This requires a MOSFET with a minimum drain-source maximum rating of
765 V and therefore an 800 V part has been selected.
Four parallel 470 µF output capacitors (COUT1 to 4) have been used with a total capacitance of 1880 µF,
combined ripple current rating of 8 A and impedance of 7 mΩ at 100 kHz. The maximum low frequency output
ripple can be calculated as follows:
𝑉𝑅𝐼𝑃𝑃𝐿𝐸 = 2∙𝜋∙𝑓
𝐼𝑂𝑈𝑇
1
2∙𝜋∙45∙1880∙10−6
= 1.88
[Vpp]
𝑎𝑐(min) ∙𝐶𝑂𝑈𝑇
[Vpp]
𝐼𝑂𝑈𝑇
𝑎𝑐(min) ∙𝑉𝑅𝐼𝑃𝑃𝐿𝐸
[F]
𝐶𝑂𝑈𝑇 = 2∙𝜋∙𝑓
Application Note
[9]
8
[10]
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Control loop
6
Control loop
The voltage mode Flyback converter operating in critical conduction mode has a basic error amplifier to output
voltage (VCOMP) transfer characteristic with a single pole of the form:
𝑉𝑂𝑈𝑇 (𝑠)
𝑉𝐶𝑂𝑀𝑃 (𝑠)
≈
𝑘∙𝑓𝑠
𝐷
∙
1
1+
[11]
𝑠
𝜔𝑝𝑜
Where,
𝜔𝑝𝑜 = 𝑅
2
𝐿𝑂𝐴𝐷 ∙𝐶𝑂𝑈𝑇
, 𝑅𝐿𝑂𝐴𝐷 =
𝑉𝑂𝑈𝑇
𝐼𝑂𝑈𝑇
And 'k' is a constant of approximately 2.5 x 10-6 defined by the IRS2982S.
To prevent over-shoot of the output voltage at start up while maintaining good regulation, power factor and
line current THD a type 2 compensation network is used at the COMP pin, which is the output of the IRS2982S
internal OTA error amplifier. The loop gain needs to cross 0 dB below the minimum line frequency with
sufficient margin to achieve good PF/iTHD performance.
VAUX
Rupper
VREF
gm
VCOMP
Rlower
CP
R
CZ
Figure 5
Type 2 OTA compensation
The transfer function has a zero at low frequency formed by R (RCMP) and CZ (CCMP2) and a pole at higher
frequency formed by R and CP (CCMP1). The OTA gm is approximately 100 µΩ-1 as specified in the data sheet.
The error amplifier transfer function is as follows:
𝑉𝐶𝑂𝑀𝑃 (𝑠)
𝑉𝐼𝑁 (𝑠)
𝑅𝐿𝑂𝑊𝐸𝑅. 𝑔𝑚. 𝑅
𝐿𝑂𝑊𝐸𝑅 +𝑅𝑈𝑃𝑃𝐸𝑅
≈𝑅
1+
1
𝑠𝑅𝐶𝑧
∙ 1+𝑠𝑅𝐶
[12]
𝑝
The mid-band gain is given by:
𝐺𝑜 = 𝑅
𝑅𝐿𝑂𝑊𝐸𝑅. 𝑔𝑚 𝑅
[13]
𝐿𝑂𝑊𝐸𝑅 +𝑅𝑈𝑃𝑃𝐸𝑅
Application Note
9
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Control loop
The zero is given by:
1
[14]
𝜔𝑧 = 𝑅.𝐶
𝑧
The pole is given by:
1
[15]
𝜔𝑝 = 𝑅.𝐶
𝑝
Figure 6
Bode plot showing gain and phase with type 2 compensation at full load, low line
The red lines show the converter plant transfer function from VCOMP to VOUT and the blue lines show the feedback
network and error amplifier transfer function. These are added together to give the loop transfer function T(s)
shown by the dotted line.
It can be seen that at maximum load the gain crosses zero dB at approximately 20 Hz and the phase margin is
87 °, which provides a stable system. Bode plots at different line and load conditions indicate that the system
will always be stable.
Application Note
10
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Bill of materials
7
Bill of materials
Quantity
Designator
Manufacturer
Part Number
Value/Rating
1
BR1
Vishay
GBU4J-E3/51
600 V/4 A
1
CCF
TDK
C2012X7R2E102K085AA
1 nF/250 V/0805/10%
1
CCMP1
TDK
CGA4C2C0G1H223J060AA
22 nF/250 V/0805/10%
1
CCMP2
TDK
C2012X7R1E224K125AB
0.22 µF/25 V/0805/10%
1
CDC
Epcos
B32922C3104M
0.1 µF/305 VAC/X2
1
CFB
TDK
C3216CH1H103K085AA
10 nF/50 V/1206/10%
1
COM1
Keystone
5001
0.04" dia black
1
COM2
Keystone
5001
0.04" dia black
1
COMP
Keystone
5004
0.04" dia yellow
1
COUT1
Panasonic
EEU-FR1J471B
470 µF/63 V/20%
1
COUT2
Panasonic
EEU-FR1J471B
470 µF/63 V/20%
1
COUT3
Panasonic
EEU-FR1J471B
470 µF/63 V/20%
1
COUT4
Panasonic
EEU-FR1J471B
470 µF/63 V/20%
1
CSNB
TDK
C4532X7R3A102M200KA
1 nF/1 kV/20%/1812/X7R
1
CVB
TDK
C3216X5R1H106K160AB
10 µF/50 V/1206/10%
1
CVCC1
TDK
C3216C0G1H104J160AA
0.1 µF/50 V/1206/5%
1
CVCC2
Panasonic
EEU-EB1H220S
10 µF/50 V/1206/10%
1
CX1
Epcos
B32922C3104M
0.1 µF/305 VAC/X2
1
CX2
Epcos
B32922C3224M
0.22 µF/305 VAC/X2
1
CY1
Vishay
VY2102M29Y5US63V7
1 nF/300 VAC/Y
1
CY2
Vishay
VY2102M29Y5UG63V7
1 nF/300 VAC/Y
1
CY3
Vishay
VY2102M29Y5US63V7
1 nF/300 VAC/Y
1
CZX
Kemet
C0805C220J5GACTU
22 pF/50 V/0805/5%
1
DOUT
Diodes Inc
SBR20A300CT
300 V/10 A/TO-220AB
1
DSNB
Diodes Inc
RS1MB-13-F
1000 V/1 A/SMB
1
DVCC1
Diodes Inc
LL4148-13
75 V/0.15 A/MINIMELF
1
DVCC2
Diodes Inc
LL4148-13
75 V/0.15 A/MINIMELF
1
DZ
Micro Commercial Co
BZV55C18-TP
18 V/0.5 W/MINIMELF
1
F1
Bussman
SS-5H-1.6A-APH
T1.6 A/300 VAC/4-8.5
1
IC1
Infineon
IRS2982S
SMPS Controller
1
IFB
Keystone
5003
0.04" dia orange
1
L1
Kemet
SS24H-R05600-CH
2x60 mH Common Mode
1
MFB
Infineon
IPA80R650CE
800 V/4.5 A/TO-220
1
P1
Phoenix Contact
1985205
3 Position 3.5mm Green
1
P2
Phoenix Contact
1985195
2 Position 3.5mm Green
1
1
Test results are based on this part.
Application Note
11
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Bill of materials
Quantity
Designator
Manufacturer
Part Number
Value/Rating
1
PFC
Keystone
5002
0.04" dia white
1
RCF
Panasonic
ERJ-6GEYJ471V
470/0.125 W/0805/5%
1
RCMP
Panasonic
ERJ-6GEYJ334V
330 k/0.125 W/0805/5%
1
RCS1
Panasonic
ERJ-8GEYJ4R7V
4.7/0.25 W/1206/5%
1
RCS2
Panasonic
ERJ-8GEYJ1R5V
1.5/0.25 W/1206/5%
1
RCS3
Panasonic
ERJ-8GEYJ1R5V
1.5/0.25 W/1206/5%
1
RCS4
Panasonic
ERJ-8GEYJ1R5V
1.5/0.25 W/1206/5%
1
RFB1
Panasonic
ERJ-8GEYJ105V
1 M/0.25 W/1206/5%
1
RFB2
Panasonic
ERJ-8GEYJ203V
20 k/0.25 W/1206/5%
1
RG1
Panasonic
ERJ-8GEYJ4R7V
4.7/0.25 W/1206/5%
1
RG2
Panasonic
ERJ-8GEYJ103V
10 k/0.25 W/1206/5%
1
RHV
Yageo
CFR-50JB-52-10K
10 k/0.5 W/5%
1
ROUT
Panasonic
ERJ-8GEYJ153V
15 k/0.25 W/1206/5%
1
RSNB1
Panasonic
ERJ-8GEYJ474V
470 k/0.25 W/1206/5%
1
RSNB2
Panasonic
ERJ-8GEYJ474V
470 k/0.25 W/1206/5%
1
RSNB3
Panasonic
ERJ-8GEYJ474V
470 k/0.25 W/1206/5%
1
RVCC1
Panasonic
ERJ-8GEYJ100V
10/0.25 W/1206/5%
1
RVCC2
Panasonic
ERJ-8GEYJ511V
510/0.25 W/1206/5%
1
RZX1
Panasonic
ERJ-8GEYJ473V
47 k/0.25 W/1206/5%
1
RZX2
Panasonic
ERJ-6ENF1402V
14 k/0.125 W/0805/1%
1
T1
Finepower
Wurth
TPT-PQ2627-001A
750316066 Rev 00
Flyback Transformer
800 µH 64:18:7
1
VCC
Keystone
5000
0.04" dia red
1
VCS
Keystone
5003
0.04" dia orange
1
VDC(HV)
Keystone
5000
0.04" dia red
1
VOUT+
Keystone
5000
0.04" dia red
1
VOUT-
Keystone
5001
0.04" dia black
1
VR1
Epcos
S10K320E2K1
510 V/3.5 kA/10 mm
1
ZX
Keystone
5004
0.04" dia yellow
Application Note
12
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Transformer specification
8
Transformer specification
Core type and material: Wurth 150-2239 PQ2625, PC44
Bobbin : THT, Vertical, Wurth p/n: 070-5649
Primary inductance and leakage inductance:
Lp = 795µH (±5%), measured between pin1 and pin3, leakage inductance ≤ 10µH
Start
3
11,12
5
9,10
2
Figure 7
End
2
9,10
4
7,8
1
No. of Turns
31
9
7
9
33
Wire Size
1 x φ0.4mm
2 x triple φ0.45mm
1 x φ0.32mm
2 x triple φ0.45mm
1 x φ0.4mm
Layers
½ Primary
½ Secondary
Flyback Auxiliary
½ Secondary
½ Primary
Flyback transformer specification
Application Note
13
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
PCB Layout
9
PCB Layout
Figure 8
PCB top side components and traces
Figure 9
PCB bottom side components and traces
Application Note
14
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
PCB Layout
9.1
Figure 10
PCB layout guidelines for system optimization
PCB layout
The left side of the above figure shows the primary and secondary high frequency current loops surrounded by
a black outline in each case. The primary loop on the left side of the board originates from CDC connecting first
to the transformer (T1) primary (pin 1). The other side of the primary winding (pin 3) is connected to the drain of
the MOSFET (MFB). To minimize EMI this trace should be kept as short as possible, however in this board due to
the shape and the alternative DPAK footprint that has also been included, MFB could not be located directly
next to T1. A ground plane has been placed on the other side of the PCB to absorb some of the EMI. The current
sense resistors (RC1-4) are located such that the connection to the high frequency 0V bus return of CDC is
extremely short with the other end connected to the source of MFC through another short trace. A pad
connected to CDC 0V is provided so that a grounded heatsink may be used, provided the MOSFET is in an
insulated TO-220 FullPAK. This also absorbs some of the EMI originating from the drain.
The secondary high frequency current loop originates from T1 pins 11 and 12 connecting through a short trace
to DOUT, which then connects through another very short trace to COUT1. The negative side of COUT1 returns
directly back to T1 pins 7 and 8 again through another short trace providing the tightest possible HF current
loop. Parallel output capacitors COUT2-4 are connected to COUT1 through very heavy Copper traces to provide
minimum impedance and best possible HF ripple current sharing between the capacitors. A grounding pad is
also provided for the DOUT heat sink. The diode must also be in a TO-220 FullPAK to use a grounded heatsink.
The primary-secondary 0V Y capacitor (CY3) is connected directly to each 0V HF point with the shorted possible
traces. The layout techniques described minimize EMI emitted by the converter as much as possible.
Aside from EMI considerations, it is essential to design the PCB so that the IRS2982 is able to operate correctly
without suffering from potential interference caused by noise or incorrect grounding. The picture on the right
of the above figure shows the area around IC1. Pin 6 is the 0V (ground) connection, which is returned to the 0V
side of CDC through a direct connection. It is also essential that decoupling capacitor CVCC1 be located directly
next to IC1 with direct connections to the VCC and COM/0V pins.
As in all switching power supplies, the signal and power grounds must be kept separate and join together only
at the star point, which is at the negative side of the high frequency capacitor (CDC).
Components associated with IC1 such as CCF, CZX CMP1 and RCMP are connected to the signal ground with the
shortest traces possible back to pin 6.
Additionally, clearance distances between high voltage traces and other parts of the circuit are kept as large as
possible to comply with safety requirements. For this reason the middle leads of MFB and DOUT are bent
forward to connect to a pad located further from the other two pads.
Application Note
15
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Test results
10
Test results
10.1
Operation at maximum load
The following measurements were made with IPA80R650CE MOSFET fitted as MFB.
Table 1
Test result summary
Parameter
Unit
Results
VAC
Vrms
100
120
230
265
Vdrain(ref)
V
326
349
510
550
VCS_pk
V
1.19
1.06
0.73
0.69
ICS_pk
A
2.63
2.35
1.62
1.53
ton
µs
16.00
12.03
4.39
3.68
toff
µs
12.16
10.87
8.22
7.76
D
ratio?
0.57
0.53
0.35
0.32
fs
kHz
35.51
43.67
79.30
87.41
ZXmax
V
4.7
4.7
4.7
4.7
10.2
Test measurements under different line and load conditions
Table 2
Input 100 VAC
Pout
Vout
Iout
Pin
[W]
[V]
[A]
100%
51.98
51.98
50%
26.39
20%
Vout_rp
[W]
η
[%]
PF
THD
1.00
57.79
89.95
0.993
5.60%
1.50
52.77
0.50
28.94
91.17
0.994
6.10%
0.75
10.80
54.02
0.20
12.10
89.29
0.981
8.70%
0.30
0.50%
2.80
56.09
0.05
3.67
76.42
0.855
n/a
0.08
0
0.00
59.30
0.00
0.68
0.00
n/a
n/a
0.02
Vout
Iout
Pin
η
PF
THD
[%]
Vout_rp
Load
Table 3
[Vpp]
Input 120 VAC
Load
Pout
[W]
[V]
[A]
[W]
[%]
100%
52.02
52.02
1.00
57.01
91.25
0.994
5.60
1.50
50%
26.43
52.85
0.50
28.81
91.72
0.992
6.10
0.75
20%
10.82
54.12
0.20
12.14
89.16
0.971
8.50
0.30
0.50%
2.82
56.38
0.05
3.81
73.99
0.802
n/a
0.08
0
0.00
59.20
0.00
0.63
0.00
n/a
n/a
0.02
Application Note
16
[Vpp]
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Test results
Table 4
Input 230 VAC
Pout
Vout
Iout
Pin
PF
THD
[%]
Vout_rp
[W]
η
[%]
[W]
[V]
[A]
100%
52.19
52.19
1.00
56.09
93.05
0.983
9.10
1.50
50%
26.51
53.01
0.50
28.89
91.74
0.954
8.80
0.75
20%
10.83
54.17
0.20
12.51
86.60
0.825
15.40
0.30
0.50%
2.79
55.83
0.05
3.76
74.24
0.360
50.00
0.08
0
0.00
56.00
0.00
0.33
0.00
n/a
n/a
0.02
Pout
Vout
Iout
Pin
η
PF
THD
Vout_rp
[W]
[V]
[A]
[W]
[%]
[%]
[Vpp]
100%
52.22
52.22
1.00
56.12
93.05
0.975
9.90
1.50
50%
26.52
53.04
0.50
29.00
91.45
0.929
9.90
0.75
20%
10.82
54.09
0.20
12.69
85.25
0.755
16.70
0.30
0.50%
2.78
55.53
0.05
3.61
76.91
0.267
50.00
0.08
0
0.00
55.70
0.00
0.31
0.00%
n/a
n/a
0.02
Load
Table 5
[Vpp]
Input 265 VAC
Load
Application Note
17
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Test results
Line Regulation
DC Output Voltage
60,00
50,00
40,00
0.5% Load
30,00
20% Load
20,00
50% Load
10,00
100% Load
0,00
100
120
140
160
180
200
220
240
260
AC Input Voltage (RMS)
Figure 11
Line regulation at different loads
Load Regulation
DC Output Voltage
60,00
50,00
40,00
100VAC
30,00
120VAC
20,00
230VAC
10,00
265VAC
0,00
0
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
1
Load Current (A)
Figure 12
Load regulation at different AC input voltage values
Application Note
18
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Test results
Power Factor
Power Factor
1,000
0,950
0,900
0,850
0,800
0,750
0,700
0,650
0,600
0,550
0,500
100VAC
120VAC
230VAC
265VAC
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
1
Output Current (A)
Figure 13
Power factor vs load
iTHD
iTHD
50,0
45,0
40,0
35,0
30,0
25,0
20,0
15,0
10,0
5,0
0,0
100VAC
120VAC
230VAC
265VAC
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
1
Output Current (A)
Figure 14
THDi vs load
Application Note
19
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Test results
Efficiency
Efficiency
100,00%
90,00%
80,00%
70,00%
60,00%
50,00%
40,00%
30,00%
20,00%
10,00%
0,00%
100VAC
120VAC
230VAC
265VAC
0
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
1
Output Current (A)
Efficiency
Efficiency
100,00%
98,00%
96,00%
94,00%
92,00%
90,00%
88,00%
86,00%
84,00%
82,00%
80,00%
100VAC
120VAC
230VAC
265VAC
0
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
1
Output Current (A)
Figure 15
Efficiency vs load
Application Note
20
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Test results
10.3
Start and steady state operation at maximum load
Figure 16
100 VAC steady state operation at 100% load
Input current (yellow), CS (blue), VCC (red), VOUT ripple (green)
Figure 17
100 VAC start-up at 100% load
Input current (yellow), CS (blue), VCC (red), VOUT (green)
Application Note
21
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Test results
Figure 18
230 VAC steady state operation at 100% load
Input current (yellow), CS (blue), VCC (red), VOUT ripple (green)
Figure 19
230 VAC start-up at 100% load
Input current (yellow), CS (blue), VCC (red), VOUT (green)
At both 120 VAC and 230 VAC with full load the output voltage rises within the specified time with minimal or no
over-shoot. Cycle by cycle current limit operates for the first few AC line half-cycles limiting inrush current.
Application Note
22
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Test results
10.4
Start-up under different line and load conditions
Figure 20
100 VAC start-up at 100% load
Output voltage (yellow), VCOMP (red), VFB (green)
Figure 21
120 VAC start-up at 100% load
Output voltage (yellow), VCOMP (red), VFB (green)
Application Note
23
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Test results
Figure 22
230 VAC start-up at 100% load
Output voltage (yellow), VCOMP (red), VFB (green)
Figure 23
265 VAC start-up at 100% load
Output voltage (yellow), VCOMP (red), VFB (green)
Application Note
24
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Test results
Figure 24
120 VAC start-up at 50% load
Output voltage (yellow), VCOMP (red), VFB (green)
Figure 25
120 VAC start-up at 20% load
Output voltage (yellow), VCOMP (red), VFB (green)
Application Note
25
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Test results
Figure 26
230 VAC start-up at 50% load
Output voltage (yellow), VCOMP (red), VFB (green)
Figure 27
230 VAC start-up at 20% load
Output voltage (yellow), VCOMP (red), VFB (green)
Application Note
26
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Test results
Figure 28
120 VAC start-up at 0% load
Output voltage (yellow), VCOMP (red), VFB (green)
Figure 29
265 VAC start-up at 0% load
Output voltage (yellow), VCOMP (red), VFB (green)
Application Note
27
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Test results
10.5
Operation at line peak and zero crossing
Figure 30
120 VAC at 100% load, AC line peak
Gate drive (yellow), CS (blue), VZX (red), Vdrain (green)
Figure 31
120 VAC at 100% load line zero-crossing
Gate drive (yellow), CS (blue), VZX (red), Vdrain (green)
Application Note
28
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Test results
Figure 32
230 VAC at 100% load line peak
Gate drive (yellow), CS (blue), VZX (red), Vdrain (green)
Figure 33
230 VAC at 100% load line zero-crossing
Gate drive (yellow), CS (blue), VZX (red), Vdrain (green)
Close to the line zero-crossing the amplitude of VZX is below the VZX+ threshold of 1.54 V so the next switching
cycle is not started until the restart interval timeout period tWD. This does not significantly impact power factor
and THD.
Application Note
29
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Test results
10.6
Burst mode operation at zero load
Figure 34
120 VAC start-up at 0% load burst mode operation
Gate drive (yellow), VCOMP (blue), VZX (red)
Figure 35
230 VAC start-up at 0% load burst mode operation
Gate drive (yellow), VCOMP (blue), VZX (red)
Application Note
30
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Test results
10.4
Figure 36
10.8
Figure 37
Light load DCM operation
100 VAC start-up at zero load
Gate drive (yellow), VCOMP (blue), VZX (red), Vdrain (green)
Over-voltage protection through ZX
265 VAC load step from 100% to 0%
VOUT (yellow), Gate drive (blue), VCOMP (red), VZX (green)
Application Note
31
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Test results
10.9
High voltage start-up operation
The high voltage start-up (HV pin) input current is measured with a 10 k resistor (RHV) connected from HV to the
bus so that the oscilloscope traces in the following figures display approximately 1 mA/div:
Figure 38
100 VAC start-up at 100% load
HV start-up current (yellow), VFB (blue), VCC (red), Gate drive (green)
Figure 39
265 VAC start-up at 100% load
HV start-up current (yellow), VFB (blue), VCC (red), Gate drive (green)
Application Note
32
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Test results
10.10
High voltage start-up cell operation during zero load burst mode
Figure 40
120 VAC start-up at 0% load
HV start-up current (yellow), VFB (blue), VCC (red), Gate drive (green)
Figure 41
230 VAC start-up at 0% load
HV start-up current (yellow), VFB (blue), VCC (red), Gate drive (green)
These waveforms show that in burst mode the auxiliary winding is able to supply VCC therefore the HV start-up
cell support mode does not come into operation.
Application Note
33
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Test results
10.11
Thermal Performance under normal operating conditions
Figure 42
100 VAC at 100% load (board top and bottom sides)
Figure 43
265 VAC at 100% load (board top and bottom sides)
Application Note
34
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Test results
10.12
Thermal Performance under abnormal operating conditions
10.12.1
Open feedback loop (RFB1 removed), VCC supply connected
The IRS2982S (IC1) reaches maximum case temperature at high line, 20% load. Temperature is measured in
ambient of 25 °C.
Figure 44
265 VAC at 20% load (IHV is 1 mA/div)
VCC (yellow), VCOMP (blue), IHV (red), VOUT (green)
Application Note
35
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Test results
Figure 45
10.12.2
265 VAC at 20% load, IRS2982S case temperature
VCC supply removed (DVCC2 removed), feedback loop connected
The IRS2982S (IC1) reaches maximum case temperature at high line, 20% load. Temperature is measured in
ambient of 25 °C.
Figure 46
265 VAC at 20% load (IHV is 1mA/div)
VCC (yellow), VCOMP (blue), IHV (red), VOUT (green)
Figure 47
265 VAC at 20% load, IRS2982S case temperature
Application Note
36
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Test results
10.12.3
Reduced VCC supply (Support mode)
The IRS2982S (IC1) reaches maximum case temperature at high line, 20% load. Temperature is measured in
ambient of 25 °C. VCC is supplied from an external supply maintained just above the UVLO threshold.
Figure 48
265 VAC at 20% load (IHV is 1mA/div)
VCC (yellow), VCOMP (blue), IHV (red), VOUT (green)
Figure 49
265 VAC at 100% load, IRS2982S case temperature
Application Note
37
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Test results
10.13
Table 1
Line current harmonics according to EN61000-3-2
EN61000-3-2 Class C limits for system power >25 W
Percentage of Fundamental
120 VAC, 100% Load, Line Current Harmonics (%)
3,00E+01
2,50E+01
2,00E+01
1,50E+01
Harmonic (%)
1,00E+01
Limit
5,00E+00
0,00E+00
1
3
5
7
9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
Harmonic
Figure 50
Harmonic test results at 120 VAC and 100% load
Application Note
38
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Test results
Percentage of Fundamental
120 VAC, 50% Load, Line Current Harmonics (%)
3,00E+01
2,50E+01
2,00E+01
1,50E+01
Harmonic (%)
1,00E+01
Limits
5,00E+00
0,00E+00
1
3
5
7
9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
Harmonic
Figure 51
Harmonic test results at 120 VAC and 50% load
Percentage of Fundamental
230VAC, 100% Load, Line Current Harmonics (%)
3,00E+01
2,50E+01
2,00E+01
1,50E+01
Harmonic (%)
1,00E+01
Limit
5,00E+00
0,00E+00
1
3
5
7
9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
Harmonic
Figure 52
Harmonic test results at 230 VAC and 100% load
Application Note
39
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Test results
Percentage of Fundamental
230VAC, 50% Load, Line Current Harmonics (%)
3,00E+01
2,50E+01
2,00E+01
1,50E+01
Harmonic (%)
1,00E+01
Limit
5,00E+00
0,00E+00
1
3
5
7
9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
Harmonic
Figure 53
Harmonic test results at 230 VAC and 50% load
Class C limits are met at 50% and 100% loads at 120 VAC and 230 VAC.
10.13.1
Figure 54
EMI Conducted Emissions (tested to CISPR22 limits)
Conducted emissions at 120 VAC and 100% load
Application Note
40
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Test results
Figure 55
Conducted emissions at 230 VAC and 100% load
The red limit line shows the limit for the quasi-peak measurement, for which the frequency sweep trace is also
shown in red. To pass the red trace must to remain below the red limit line and the pink average measurement
trace must remain below the yellow average limit line. The orange peak trace may be disregarded.
EMI emissions are very dependent on the board layout, please refer to section 9.1.
Note:
Infineon Technologies does not guarantee compliance with any EMI standard.
Application Note
41
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Conclusion
11
Conclusion
The specifications as listed in section 3.2 are met with efficiency exceeding 90% across the full line input
voltage range from 50% to 100% load. Power factor remains above 0.95 at 120 VAC and 230 VAC nominal inputs
from 50% load to 100%. The input current total harmonic distortion (iTHD) remains below 10% from 20% to
100% load over at 120 VAC input and from 70% to 100% load at 230 VAC, remaining below 20% down to 20% load
from 100 to 265 VAC. At lighter loads power factor falls and iTHD increases, however output voltage regulation
remains tight. Output voltage ripple at twice the AC line frequency remains 1.6 Vpp at full load at 60 Hz
independent of the input voltage, which matches the calculated value from equation (10). Type 2
compensation of the operational trans-conductance error amplifier (OTA) provides tight load regulation from
10% to 100% load with a small increase below 10%. The output voltage rises to its operating level in less than
300 ms with no overshoot from 100 VAC to 265 VAC with only minimal overshoot at 100 VAC over the full load
range. Performance indicates an over-damped control loop corresponding to the phase margin determined in
section 6. The type 2 control loop compensation network successfully controls the startup and settling
response while providing high power factor and low iTHD over a wide line/load range, which is able to meet
EN61000-3-2 class C requirements for lighting apparatus. Over voltage protection as detected through the ZX
input operates correctly to limit the output voltage under open and very light load conditions. Operation in
DCM and burst mode are also seen to maintain output voltage regulation where necessary. Cycle by cycle
primary over current protection operates correctly at start-up to limit inductor current and stress of the
MOSFET. Operating waveforms confirm the calculated peak current value from section 5.
Thermal performance under normal operating conditions (measured in open air at 25 degrees C ambient) as
shown in section 10.11, indicates a temperature rise of 45°C at the transformer windings, however the cores
remain at a lower temperature. The input bridge (BR1) operates component at low line with a rise of 33°C with a
greatly reduced temperature rise at high line of 23°C. The MOSFET (MFB) has a 37°C rise at low line and a 24°C
rise at high line due to higher primary peak current at low line for the IPA80R650CE measured with no heatsink
attached.
Under all normal conditions the high voltage start-up cell is deactivated as the feedback loop closes and it
switches over from start-up mode to support mode. The HV cell allows the power supply to start up rapidly at
any line input voltage, meeting the maximum specification of 300 ms from switch on to reaching nominal
output voltage.
Standy power is composed of the power dissipated in the output resistor ROUT and the power consumed by the
controller IC VCC supplying the MOSFET gate drive during burst mode operation as shown in figures 34 and 35.
The power dissipated in ROUT is 240 mW in this design, which can be reduced by increasing the resistor value
athough this could cause the output to sightly exceed 60 V under an open load condition. This would not be an
issue in designs with lower output voltages. Figure 35 shows that the burst duration at 230 VAC is much shorter
than that at 120 VAC as shown in figure 34, which explains why the standby power is higher at low line.
Application Note
42
Rev 1.1
2016-03-09
IRXLED04
55 W Flyback converter design using the IRS2982S controller
Conclusion
Under fault conditions as shown in section 10.12, the start-up cell continues to operate in support mode in the
following cases:
1.
2.
3.
The feedback loop is open because the IRS2982S never switches to support mode. In this case there is
no output voltage regulation however the output voltage is limited by continuous operation of the
over-voltage protection. The IRS2982S draws between 1 and 2 mA under this condition causing the case
temperature to rise 50°C at maximum line input 265 VAC. The IC would therefore remain within its
recommended operating range at an ambient temperature up to 75°C.
VCC is not supplied through the auxiliary transformer winding but the feedback loop is still connected.
In this case the HV start-up cell operating in support mode supplies all of the current to VCC. At
maximum line input with 20% load, which is the worst case, the IRS2982S case temperature rises nearly
80°C. At a high ambient temperature there is a risk that the IC could exceed its maximum recommended
operating temperature of 125°C. This situation should be avoided by ensuring that VCC receives current
from the auxiliary winding during initial testing of the board.
VCC is not sufficiently supplied through the auxiliary transformer winding so that the HV start-up cell
continues to supply current in support mode. For this test the auxiliary VCC supply was adjusted to
maintain VCC just above the under-voltage lock-out threshold where the HV start-up cell continues to
supply a little over 1 mA during normal operation. In this case at maximum line input the IRS2982S case
temperature rise measured was 40°C.
Quasi-peak and average conducted emission sweeps fall within limits over the frequency spectrum from
150 kHz to 30 MHz. It should be noted that these measurements were not made by a certified test lab and are
intended only as an indication of performance.
In conclusion, the IRS2982S based Flyback converter design provides excellent performance and robustness
with tight control and reliable protection. This design is well suited as a front end section in a two stage LED
driver, where the back end section would typically be a constant current regulated Buck stage. Since there is no
output over-load or short circuit protection the output current can reach several Amps, therefore the converter
could become damaged under prolonged operation in these conditions.
References
[1] IRS2982SPBF SMPS control IC datasheet, Infineon Technologies.
Revision History
Major changes since the last revision
Page or Reference
--
Application Note
Description of change
First Release
43
Rev 1.1
2016-03-09
Trademarks of Infineon Technologies AG
AURIX™, C166™, CanPAK™, CIPOS™, CoolGaN™, CoolMOS™, CoolSET™, CoolSiC™, CORECONTROL™, CROSSAVE™, DAVE™, DI-POL™, DrBlade™, EasyPIM™,
EconoBRIDGE™, EconoDUAL™, EconoPACK™, EconoPIM™, EiceDRIVER™, eupec™, FCOS™, HITFET™, HybridPACK™, Infineon™, ISOFACE™, IsoPACK™,
i-Wafer™, MIPAQ™, ModSTACK™, my-d™, NovalithIC™, OmniTune™, OPTIGA™, OptiMOS™, ORIGA™, POWERCODE™, PRIMARION™, PrimePACK™,
PrimeSTACK™, PROFET™, PRO-SIL™, RASIC™, REAL3™, ReverSave™, SatRIC™, SIEGET™, SIPMOS™, SmartLEWIS™, SOLID FLASH™, SPOC™, TEMPFET™,
thinQ!™, TRENCHSTOP™, TriCore™.
Trademarks updated August 2015
Other Trademarks
All referenced product or service names and trademarks are the property of their respective owners.
Edition 2016-03-09
Published by
Infineon Technologies AG
81726 Munich, Germany
ifx1owners.
© 2016 Infineon Technologies AG.
All Rights Reserved.
Do you have a question about this
document?
Email: [email protected]
Document reference
AppNote Number
ANEVAL_2016_PL16_017
IMPORTANT NOTICE
The information contained in this application note
is given as a hint for the implementation of the
product only and shall in no event be regarded as a
description or warranty of a certain functionality,
condition or quality of the product. Before
implementation of the product, the recipient of this
application note must verify any function and other
technical information given herein in the real
application.
Infineon
Technologies
hereby
disclaims any and all warranties and liabilities of
any kind (including without limitation warranties of
non-infringement of intellectual property rights of
any third party) with respect to any and all
information given in this application note.
The data contained in this document is exclusively
intended for technically trained staff. It is the
responsibility of customer’s technical departments
to evaluate the suitability of the product for the
intended application and the completeness of the
product information given in this document with
respect to such application.
For further information on the product, technology,
delivery terms and conditions and prices please
contact your nearest Infineon Technologies office
(www.infineon.com).
WARNINGS
Due to technical requirements products may
contain dangerous substances. For information on
the types in question please contact your nearest
Infineon Technologies office.
Except as otherwise explicitly approved by Infineon
Technologies in a written document signed by
authorized
representatives
of
Infineon
Technologies, Infineon Technologies’ products may
not be used in any applications where a failure of
the product or any consequences of the use thereof
can reasonably be expected to result in personal
injury.