Power Transformer PC Mount: Flat Pack ™ FP40-1200 Electrical Specifications (@25C) 1. Maximum Power: 48VA 2. Primary Voltage: Series: 230V@50/60 Hz Parallel: 115V@50/60Hz 3. Secondary: Series: 40.0VCT @ 1.2Amps Parallel: 20.0V @ 1.2Amps Description: The FP40-1200 is part of a series which has a long history of reliable service in the field, made from a proven design and constructed with UL recognized materials. Construction: Wound on two dual channel nylon bobbin. Materials are UL recognized, Class B (130º C) rated. 7 8 6 5 3 4 2 1 Safety: These products are 100% hipot tested with an insulation of 2000V between primary and secondary windings and 1500V between the primary / secondary windings and the core. A Agency File: UL: File E53148, UL 506, Class B General Purpose Transformer, cUL: File E53148, UL 506, Class B General Purpose Transformer, Canadian Use B C Dimensions: A B C D E F G 3.12 2.50 1.375 0.267 0.600 0.669 2.18 D Units: In inches Weight: 21.0 oz Pin Dimension: .020 x .041 in Schematic: G 1 5 2 6 4 8 3 7 .0 6 0 D IA H OL ES E F E RoHS Compliance: As of manufacturing date February 2005, all standard products meet the requirements of 2011/65/EU, known as the RoHS initiative. * Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’ website for the most current version. Web: www.TriadMagnetics.com Phone 951-277-0757 Fax 951-277-2757 460 Harley Knox Blvd. Perris, California 92571 Publish Date: December 4, 2013