Downloads for PC Mount Flat Pack™ Power Transformers (FP34-1400)

Power Transformer
PC Mount: Flat Pack ™
FP34-1400
Electrical Specifications (@25C)
1. Maximum Power: 48 VA
2. Primary Voltage:
Series: 230V@50/60 Hz
Parallel: 115V@50/60Hz
3. Secondary:
Series:
34.0VCT @ 1.4Amps
Parallel: 17.0V @ 2.8Amps
Description:
The FP34-1400 is part of a series which has a long history of reliable service in the
field, made from a proven design and constructed with UL recognized materials.
Construction:
Wound on two dual channel nylon bobbin. Materials are UL recognized, Class B
(130º C) rated.
7
8
6
3
4
2
5
Safety:
These products are 100% hipot tested with an insulation of 2000V between
primary and secondary windings and 1500V between the primary / secondary
windings and the core.
A
1
Agency File:
UL: File E53148, UL 506, Class B General Purpose Transformer,
cUL: File E53148, UL 506, Class B General Purpose Transformer, Canadian Use
B
C
Dimensions:
A
B
C
D
E
F
G
3.12
2.50
1.375
0.267
0.600
0.669
2.18
D
Units: In inches
Weight: 21.0 oz
Pin Dimension: .020 x .041 in
Schematic:
G
1
5
2
6
4
8
3
7
.060 DIA HOLES
E
F
E
RoHS Compliance: As of manufacturing date February 2005, all standard products meet
the requirements of 2011/65/EU, known as the RoHS initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact Triad
Magnetics’ website for the most current version.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
Publish Date: December 4, 2013