SS22, SS23, SS24, SS25, SS26 www.vishay.com Vishay General Semiconductor Surface Mount Schottky Barrier Rectifier FEATURES • Low profile package • Ideal for automated placement • Guardring for overvoltage protection • Low power losses, high efficiency • Low forward voltage drop • High surge capability • Meets MSL level 1, per J-STD-020, LF maximum peak of 260 °C DO-214AA (SMB) • AEC-Q101 qualified available - Automotive ordering code: base P/NHE3 PRIMARY CHARACTERISTICS • Material categorization: for definitions of compliance please see www.vishay.com/doc?99912 IF(AV) 2.0 A VRRM 20 V, 30 V, 40 V, 50 V, 60 V IFSM 75 A VF 0.50 V, 0.70 V TJ max. 150 °C Package DO-214AA Diode variations Single MECHANICAL DATA Case: DO-214AA (SMB) Molding compound meets UL 94 V-0 flammability rating Base P/N-E3 - RoHS-compliant, commercial grade Base P/NHE3 - RoHS-compliant, AEC-Q101 qualified Base P/NHE3_X - RoHS-compliant, AEC-Q101 qualified (“_X” denotes revision code e.g. A, B,.....) TYPICAL APPLICATIONS For use in low voltage high frequency inverters, freewheeling, DC/DC converters, and polarity protection applications. Terminals: Matte tin plated leads, solderable per J-STD-002 and JESD 22-B102 E3 suffix meets JESD 201 class 2 whisker test, HE3 suffix meets JESD 201 class 2 whisker test Polarity: Color band denotes cathode end MAXIMUM RATINGS (TA = 25 °C unless otherwise noted) PARAMETER SYMBOL Device marking code SS22 SS23 SS24 SS25 SS26 S2 S3 S4 S5 S6 UNIT Maximum repetitive peak reverse voltage VRRM 20 30 40 50 60 V Maximum RMS voltage VRMS 14 21 28 35 42 V Maximum DC blocking voltage VDC 20 30 40 50 60 Max. average forward rectified current at TL (fig. 1) IF(AV) 2.0 A Peak forward surge current 8.3 ms single half sine-wave superimposed on rated load IFSM 75 A Non-repetitive avalanche energy at TA = 25 °C, IAS = 2.0 A, L = 10 mH EAS 20 mJ Electrostatic discharge capacitor voltage Human body model: C = 100 pF, R = 1.5 k VC 8.0 kV dV/dt 10 000 V/μs TJ -65 to +150 °C TSTG -65 to +150 °C Voltage rate of change (rated VR) Operating junction temperature range Storage temperature range V Revision: 04-Aug-15 Document Number: 88748 1 For technical questions within your region: [email protected], [email protected], [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 SS22, SS23, SS24, SS25, SS26 www.vishay.com Vishay General Semiconductor ELECTRICAL CHARACTERISTICS (TA = 25 °C unless otherwise noted) PARAMETER TEST CONDITIONS Maximum instantaneous forward voltage (1) 2.0 A Maximum DC reverse current at rated DC blocking voltage (1) TA = 25 °C SYMBOL SS22 SS23 VF SS25 SS26 0.7 UNIT V 0.4 IR TA = 100 °C SS24 0.5 mA 10 Note (1) Pulse test: 300 μs pulse width, 1 % duty cycle THERMAL CHARACTERISTICS (TA = 25 °C unless otherwise noted) PARAMETER SYMBOL Typical thermal resistance (1) SS22 SS23 SS24 RJA 75 RJL 17 SS25 SS26 UNIT °C/W Note PCB mounted with 0.55" x 0.55" (14 mm x 14 mm) copper pad areas (1) ORDERING INFORMATION (Example) PREFERRED P/N UNIT WEIGHT (g) PREFERRED PACKAGE CODE BASE QUANTITY DELIVERY MODE SS24-E3/52T 0.096 52T 750 7" diameter plastic tape and reel SS24-E3/5BT 0.096 5BT 3200 13" diameter plastic tape and reel SS24HE3/52T (1) 0.096 52T 750 7" diameter plastic tape and reel (1) 0.096 5BT 3200 13" diameter plastic tape and reel SS24HE3_A/H (1) 0.096 H 750 7" diameter plastic tape and reel SS24HE3_A/I (1) 0.096 I 3200 13" diameter plastic tape and reel SS24HE3/5BT Note (1) AEC-Q101 qualified 2.5 100 Peak Forward Surge Current (A) Average Forward Rectified Current (A) RATINGS AND CHARACTERISTICS CURVES (TA = 25 C unless otherwise noted) 2.0 1.5 1.0 PCB Mounted on 0.2" x 0.2" (5.0 mm x 5.0 mm) Copper Pad Area 0.5 SS22 thru SS26 0 0 25 50 75 100 125 150 At Rated TL 8.3 ms Single Half Sine-Wave 80 60 40 20 0 1 10 100 Lead Temperature (°C) Number of Cycles at 60 Hz Fig. 1 - Forward Current Derating Curve Fig. 2 - Maximum Non-Repetitive Surge Current Revision: 04-Aug-15 Document Number: 88748 2 For technical questions within your region: [email protected], [email protected], [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 SS22, SS23, SS24, SS25, SS26 www.vishay.com Vishay General Semiconductor 1000 10 TJ = 150 °C Pulse Width = 300 ˩s 1% Duty Cycle 1 TJ = 25 °C 0.1 SS22 thru SS24 100 0.01 0.2 0.4 0.6 0.8 1.0 1.2 1.4 TJ = 25 °C f = 1.0 MHz Vsig = 50 mVp-p SS22 thru SS24 SS25 and SS26 SS25 and SS26 0 Instantaneous Reverse Current (mA) Junction Capacitance (pF) Instantaneous Forward Current (A) 100 10 1.6 0.1 1 10 Instantaneous Forward Voltage (V) Reverse Voltage (V) Fig. 3 - Typical Instantaneous Forward Characteristics Fig. 5 - Typical Junction Capacitance 1000 SS22 thru SS24 SS25 and SS26 100 TJ = 150 °C 10 1 TJ = 125 °C TJ = 75 °C 0.1 TJ = 25 °C 0.01 0.001 0 20 40 60 80 100 100 Percent of Rated Peak Reverse Voltage (%) Fig. 4 - Typical Reverse Current Characteristics PACKAGE OUTLINE DIMENSIONS in inches (millimeters) DO-214AA (SMB) Cathode Band Mounting Pad Layout 0.085 (2.159) MAX. 0.155 (3.94) 0.130 (3.30) 0.086 (2.20) 0.077 (1.95) 0.086 (2.18) MIN. 0.180 (4.57) 0.160 (4.06) 0.012 (0.305) 0.006 (0.152) 0.060 (1.52) MIN. 0.096 (2.44) 0.084 (2.13) 0.220 REF. 0.008 (0.2) 0 (0) 0.060 (1.52) 0.030 (0.76) 0.220 (5.59) 0.205 (5.21) Revision: 04-Aug-15 Document Number: 88748 3 For technical questions within your region: [email protected], [email protected], [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 Legal Disclaimer Notice www.vishay.com Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. Material Category Policy Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (EEE) - recast, unless otherwise specified as non-compliant. Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU. Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21 conform to JEDEC JS709A standards. Revision: 02-Oct-12 1 Document Number: 91000