点击打开链接

Test Report.
No. SHAEC1610845801
Date: 27 May 2016 .
Page 1 of 6.
SHANGHAI SEMITECH SEMICONDCUTOR CO., LTD .
ROOM 311, UNIT 2, NO.2501, DUHUI ROAD, JINGLIN BUILDING, MINHANG DISTRICT, SHANGHAI CHINA
.
.
The following sample(s) was/were submitted and identified on behalf of the clients as : Semiconductor DICE .
SGS Job No. :
SP16-018228 - SH .
Model No. :.
Semiconductor DICE .
Material No. :.
SP16-003205-SH .
Lot No. :.
2016XP0305.
Date of Sample Received : .
23 May 2016.
Testing Period : .
23 May 2016 - 26 May 2016 .
Test Requested : .
Selected test(s) as requested by client. .
Test Method : .
Please refer to next page(s). .
Test Results :.
Please refer to next page(s). .
Signed for and on behalf of
SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd..
Helen Liu.
Approved Signatory .
Test Report.
No. SHAEC1610845801
Date: 27 May 2016 .
Page 2 of 6.
Test Results :.
Test Part Description : .
Specimen No..
SN1.
SGS Sample ID.
SHA16-108458.001
Description.
Silvery/black solid sheet .
Remarks :.
(1) 1 mg/kg = 1 ppm = 0.0001% .
(2) MDL = Method Detection Limit .
(3) ND = Not Detected ( < MDL ) .
(4) "-" = Not Regulated .
RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU.
Test Method : . (1) With reference to IEC 62321-5:2013, determination of Cadmium by ICP-OES.
(2) With reference to IEC 62321-5:2013, determination of Lead by AAS.
(3) With reference to IEC 62321-4:2013, determination of Mercury by ICP-OES.
(4) With reference to IEC 62321:2008, determination of Hexavalent Chromium by Colorimetric
Method using UV-Vis.
(5) With reference to IEC 62321-6:2015, determination of PBBs and PBDEs by GC-MS.
(6) With reference to IEC 62321-8 (111/321/CD), determination of phthalates by GC-MS. .
Test Item(s).
001.
Limit.
Unit.
MDL.
Cadmium (Cd) .
100
mg/kg.
2
ND
Lead (Pb).
1000
mg/kg.
2
72855*
Mercury (Hg).
1000
mg/kg.
2
ND
Hexavalent Chromium (Cr(VI)) .
1000
mg/kg.
2
ND
Sum of PBBs .
1000
mg/kg.
-
ND
Monobromobiphenyl .
-
mg/kg.
5
ND
Dibromobiphenyl .
-
mg/kg.
5
ND
Tribromobiphenyl .
-
mg/kg.
5
ND
Tetrabromobiphenyl .
-
mg/kg.
5
ND
Pentabromobiphenyl .
-
mg/kg.
5
ND
Hexabromobiphenyl .
-
mg/kg.
5
ND
Heptabromobiphenyl .
-
mg/kg.
5
ND
Octabromobiphenyl .
-
mg/kg.
5
ND
Nonabromobiphenyl .
-
mg/kg.
5
ND
Decabromobiphenyl .
-
mg/kg.
5
ND
1000
mg/kg.
-
ND
Sum of PBDEs .
Test Report.
No. SHAEC1610845801
Date: 27 May 2016 .
Limit.
Unit.
MDL.
001.
Monobromodiphenyl ether .
-
mg/kg.
5
ND
Dibromodiphenyl ether .
-
mg/kg.
5
ND
Tribromodiphenyl ether .
-
mg/kg.
5
ND
Tetrabromodiphenyl ether .
-
mg/kg.
5
ND
Pentabromodiphenyl ether .
-
mg/kg.
5
ND
Hexabromodiphenyl ether .
-
mg/kg.
5
ND
Heptabromodiphenyl ether .
-
mg/kg.
5
ND
Octabromodiphenyl ether .
-
mg/kg.
5
ND
Nonabromodiphenyl ether .
-
mg/kg.
5
ND
Decabromodiphenyl ether .
-
mg/kg.
5
ND
Di-butyl Phthalate (DBP) .
1000
mg/kg.
50
ND
Benzyl Butyl Phthalate (BBP) .
1000
mg/kg.
50
ND
Di-2-Ethyl Hexyl Phthalate (DEHP) .
1000
mg/kg.
50
ND
Diisobutyl Phthalates (DIBP) .
1000
mg/kg.
50
ND
Test Item(s).
Page 3 of 6.
Notes :.
(1) The maximum permissible limit is quoted from RoHS Directive (EU) 2015/863.
(2) On 4 June 2015, Commission Directive (EU) 2015/863 was published in the Official Journal of the
European Union (OJEU) to include the phthalates BBP, DBP, DEHP and DIBP into ANNEX II of the Rohs
Recast Directive. The new law restricts each phthalate to no more than 0.1% in each homogeneous
material of an electrical product.
(3) The restriction of DEHP, BBP, DBP and DIBP shall apply to medical devices, including in vitro medical
devices, and monitoring and control instruments, including industrial monitoring and control instruments,
from 22 July 2021.
(4) The restriction of DEHP, BBP, DBP and DIBP shall not apply to cables or spare parts for the repair,
the reuse, the updating of functionalities or upgrading of capacity of EEE placed on the market before 22
July 2019, and of medical devices, including in vitro medical devices, and monitoring and control
instruments, including industrial monitoring and control instruments, placed on the market before 22 July
2021.
(5) The restriction of DEHP, BBP and DBP shall not apply to toys which are already subject to the
restriction of DEHP, BBP and DBP through entry 51 of Annex XVII to Regulation (EC) No 1907/2006.
(6)* Test result is only for reference .
Test Report.
No. SHAEC1610845801
Date: 27 May 2016 .
Page 4 of 6.
ATTACHMENTS
RoHS Testing Flow Chart
1) Name of the person who made testing: David Lee/Gary Xu/Shimin Zhang/ Jing Zhang
2) Name of the person in charge of testing: Jan Shi/Luna Xu/Jessy Huang/Stone Chen
3) These samples were dissolved totally by pre-conditioning method according to below flow chart.
(Cr6+ and PBBs/PBDEs test method excluded)
Sample Preparation
Sample Measurement
Pb/Cd/Hg
Acid digestion with
microwave/ hotplate
Sample solvent
extraction
Filtration
Concentration/
Dilution of extraction
solution
Solution
+
PBBs/PBDEs
Cr6
Nonmetallic
material
Adding digestion
reagent
Residue
GC-MS
Heating to 90~95℃
for extraction
Filtration and pH
adjustment
DATA
ICP-OES/AAS
DATA
Positive
Spot test
Negative
Filtration
1) Alkali Fusion /
Dry Ashing
2) Acid to dissolve
Metallic
material
Adding 1,5diphenylcarbazide
for color
development
UV-Vis
DATA
Boiling water
extraction
Adding 1,5diphenylcarbazide
for color
development
A red color
indicates the
6+
presence of Cr .
If necessary,
confirm with UVVis.
DATA
Test Report.
No. SHAEC1610845801
Date: 27 May 2016 .
ATTACHMENTS
Phthalates Testing Flow Chart
1) Name of the person who made testing: Sherlock Gao
2) Name of the person in charge of testing: Jessy Huang
Sample cutting/preparation
Sample measurement
Solvent extraction
Concentration/Dilution
Filtration
GC-MS
DATA
Page 5 of 6.
Test Report.
No. SHAEC1610845801
Date: 27 May 2016 .
Sample photo: .
SHAEC1610845801
SHA16-108458.001 .
SGS authenticate the photo on original report only .
*** End of Report *** .
Page 6 of 6.