600A/9.5 kV Thyristor - For Soft Starters, Power-Supplies and General-Purpose Drives

Product Brief
600 A / 9.5 kV Thyristor
For medium-voltage soft starters,
power supplies and general-purpose drives
The 9.5 kV thyristor silcon controlled rectifiers (SCRs) disc has been developed and
designed for the special requirements of medium-voltage soft starter as well as mediumvoltage power supply applications. For these kinds of applications, it is necessary to use
several silicon controlled rectifiers in series connection. The T600N95TOH is optimized
to deliver excellent voltage sharing under all operating conditions. High-tech production
processes deliver outstanding dynamic parameters for best-cost designs with less
series-connected devices. The SCR is also suitable for general-purpose line voltage
rectifier applications, e.g. power supplies and general-purpose drives.
Key benefits
››Less devices in series due to high
blocking voltage
››Simple way of series connection
››High surge current capability
››Easy for mounting due to standard
housing
Key features
6.5kV SCR
No. of SCRs per soft starter
40
››Ratings
42
9.5kV SCR
36
30
30
30
30
20
18
12
10
6
0
12 12
6
6
2.3kV
3.3kV
4.16kv
18
12
6.0kV
VDRM = VRRM = 9500 V
ITAVM = 600 A
››Housing Dimensions
Height = 26 mm
Diameter = 75 mm
18
12
6.6kV
Applications
10.0kV
13.8kV
15.0kV
Line Voltage
The diagram above shows that 33 % - 50 % fewer SCRs, heat sinks and gate units are
needed 9.5 kV SCRs are used instead of the 6.5 kV versions. This results in both significant
cost and volume reductions as well as higher reliability.
www.infineon-bipolar.com | www.ifbip-shop.com
››Medium-voltage soft starters
››Medium-voltage power supplies
››General-purpose drives
Product Brief
600 A/9.5 kV Thyristor
For medium-voltage soft starters,
power supplies and general-purpose drives
Electrical parameters
T600N95TOH
››V
››V
››t ››I
››I
=VRRM =9500 V
=VRWM =8000 V
DWM
=10 ms; tp1 =300 us
p
=600 A
(T
=85 °C)
TAVM
C
=12 kA
TSM
DRM
According to IEC standard 60747-6
›› V
– Non-repetitive peak off-state voltage
The highest instantaneous voltage of any non-repetitive
off-state voltage.
›› VDRM – Repetitive peak off-state voltage
The highest instantaneous voltage of any repetitive
offstate voltage.
›› VDWM – Crest working off-state voltage
The highest instantaneous value of the off-voltage,
excluding all repetitive and non-repetitive transient
voltages.
DSM
Sales Information
Part number
Status
Order number
T600N95TOH
in production
SP000972222
Published by
Infineon Technologies Bipolar GmbH & Co. KG
Max-Planck-Str. 5
59581 Warstein
Tel. +49 (0) 2902 98 99-0
Fax +49 (0) 2902 98 99-2482
HRB 8147
© 2016 Infineon Technologies Bipolar GmbH & Co. KG.
All Rights Reserved.
Visit us:
www.ifbip.com | www.ifbip-shop.com
Please note!
THIS DOCUMENT IS FOR INFORMATION PURPOSES ONLY AND
ANY INFORMATION GIVEN HEREIN SHALL IN NO EVENT BE
REGARDED AS A WARRANTY, GUARANTEE OR DESCRIPTION OF
ANY FUNCTIONALITY, CONDITIONS AND/OR QUALITY OF OUR
PRODUCTS OR ANY SUITABILITY FOR A PARTICULAR PURPOSE.
WITH REGARD TO THE TECHNICAL SPECIFICATIONS OF OUR
PRODUCTS, WE KINDLY ASK YOU TO REFER TO THE RELEVANT
PRODUCT DATA SHEETS PROVIDED BY US. OUR CUSTOMERS AND
THEIR TECHNICAL DEPARTMENTS ARE REQUIRED TO EVALUATE
THE SUITABILITY OF OUR PRODUCTS FOR THE INTENDED
APPLICATION.
WE RESERVE THE RIGHT TO CHANGE THIS DOCUMENT AND/OR
THE INFORMATION GIVEN HEREIN AT ANY TIME.
Order Number: B157-H9597-V5-7600-EU-EC-P
Date: 05 / 2016
Additional information
For further information on technologies, our products, the
application of our products, delivery terms and conditions
and/or prices, please contact your nearest Infineon Technologies
office (www.infineon.com).
Warnings
Due to technical requirements, our products may contain
dangerous substances. For information on the types in question,
please contact your nearest Infineon Technologies office.
Except as otherwise explicitly approved by us in a written
document signed by authorized representatives of Infineon
Technologies, our products may not be used in any lifeendangering applications, including but not limited to medical,
nuclear, military, life-critical or any other applications where a
failure of the product or any consequences of the use thereof
can result in personal injury.