058/059 PLL-SI Datasheet

058/059 PLL-SI
www.vishay.com
Vishay BCcomponents
Aluminum Electrolytic Capacitors
Power Long Life Snap-In
FEATURES
• Long useful life: 10 000 h at +105 °C
• High ripple current capability
• Keyed polarity version available
• Polarized aluminum electrolytic capacitors, non-solid
electrolyte
• Large types, minimized dimensions, cylindrical aluminum
case, insulated with a blue sleeve
159 PUL-SI
• Material categorization: for definitions of compliance
please see www.vishay.com/doc?99912
smaller
dimensions
APPLICATIONS
058/059
PLL-SI
• Computer, telecommunication and industrial systems
056/057
PSM-SI
85 °C
• Smoothing and filtering applications
Fig. 1
• Standard and switched mode power supplies
• Energy storage in pulse systems
QUICK REFERENCE DATA
VALUE
DESCRIPTION
058
MARKING
059
Nominal case sizes
22 x 25 to 35 x 50
(Ø D x L in mm)
Rated capacitance range 
33 μF to 47 000 μF
(E6 series), CR
Tolerance on CR
± 20 %
Rated voltage range, UR
10 V to 100 V
200 V to 400 V
Category temperature range -40 °C to 105 °C -25 °C to 105 °C
50 V: 2000 h;
Endurance test at 105 °C
 63 V: 5000 h
50 V: 5000 h;
Useful life at 105 °C
 63 V: 10 000 h
Useful life at 40 °C,
50 V: 125 000 h;
1.9 x IR applied
 63 V: 250 000 h
Shelf life at 0 V, 105 °C
500 h
Max. RMS value of
n/a
12 V
ripple voltage
Based on sectional
IEC 60384-4 / EN130300
specification
Climatic category IEC 60068
40/105/56
25/105/56
The capacitors are marked (where possible) with the
following information:
• Rated capacitance (in μF)
• Tolerance code on rated capacitance, code letter in
accordance with IEC 60062 (M for ± 20 %)
• Rated voltage (in V)
• Date code (YYMM)
• Name of manufacturer
• Code for factory of origin
• “-” sign to identify the negative terminal, visible from the
top and side of the capacitor
• Code number
• Climatic category in accordance with IEC 60068
SELECTION CHART FOR CR, UR, AND RELEVANT NOMINAL CASE SIZES FOR 058 SERIES (Ø D x L in mm)
CR
(μF)
330
470
680
1000
1500
Revision: 20-May-15
10
-
16
-
25
-
UR (V)
40
22 x 25
-
50
22 x 25
22 x 30
-
63
22 x 25
22 x 30
25 x 30
22 x 40
100
22 x 25
22 x 30
25 x 30
22 x 40
30 x 30
25 x 40
30 x 40
25 x 50
Document Number: 28342
1
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
058/059 PLL-SI
www.vishay.com
Vishay BCcomponents
SELECTION CHART FOR CR, UR, AND RELEVANT NOMINAL CASE SIZES FOR 058 SERIES (Ø D x L in mm)
CR
(μF)
2200
3300
4700
6800
10 000
15 000
22 000
33 000
47 000
10
16
25
UR (V)
40
50
63
100
-
-
22 x 25
22 x 30
25 x 30
30 x 30
35 x 40
-
-
-
-
22 x 40
25 x 40
30 x 50
-
22 x 25
22 x 30
25 x 30
30 x 30
30 x 40
35 x 50
-
-
-
22 x 40
25 x 40
25 x 50
-
22 x 25
22 x 30
25 x 30
30 x 30
30 x 40
35 x 40
-
-
-
22 x 40
25 x 40
25 x 50
30 x 50
22 x 30
25 x 30
30 x 30
30 x 40
35 x 40
35 x 50
-
-
22 x 40
25 x 40
25 x 50
30 x 50
-
-
25 x 30
30 x 30
30 x 40
35 x 40
35 x 50
-
-
22 x 40
25 x 40
25 x 50
30 x 50
-
-
-
30 x 30
30 x 40
35 x 40
35 x 50
-
-
-
25 x 40
25 x 50
30 x 50
-
-
-
-
30 x 40
35 x 40
35 x 50
-
-
-
-
25 x 50
30 x 50
-
-
-
-
-
35 x 40
35 x 50
-
-
-
-
-
30 x 50
-
-
-
-
-
-
35 x 50
-
-
-
-
-
-
SELECTION CHART FOR CR, UR, AND RELEVANT NOMINAL CASE SIZES FOR 059 SERIES (Ø D x L in mm)
UR (V)
CR
(μF)
200
250
385
400
33
-
-
22 x 25
-
47
-
-
22 x 30
22 x 30
-
22 x 25
22 x 35
22 x 35
-
-
25 x 30
25 x 30
22 x 25
22 x 30
30 x 30
30 x 30
-
-
25 x 40
25 x 40
22 x 30
22 x 35
25 x 50
30 x 35
68
100
150
220
330
470
680
1000
Revision: 20-May-15
-
25 x 30
30 x 40
25 x 50
22 x 35
30 x 30
35 x 40
35 x 40
25 x 30
25 x 35
30 x 50
30 x 50
30 x 30
30 x 35
35 x 50
35 x 50
25 x 40
25 x 50
-
-
30 x 35
35 x 35
-
-
25 x 50
30 x 45
-
-
35 x 35
35 x 45
-
-
30 x 45
-
-
-
35 x 50
-
-
-
Document Number: 28342
2
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
058/059 PLL-SI
www.vishay.com
Vishay BCcomponents
DIMENSIONS in millimeters AND AVAILABLE FORMS
TWO TERMINAL SNAP-IN
ØD
+ TERMINAL
L
L+2
max.
- TERMINAL
5.8
Bottom view
10 ± 0.1
+0
-1
The minus terminal can be marked with a black dot or with an imprinted
“-” sign.
Ø 2 ± 0.1 (2 x)
Fig. 2 - Two terminal snap-in
Fig. 3 - Mounting hole diagram
THREE TERMINAL SNAP-IN
ØD
Ø 2 ± 0.1 (2 x)
Ø 2.5 ± 0.1
+ TERMINAL
L+2
max.
L
- TERMINAL
10 ± 0.1
3.3 ± 0.1
minus pole
marking
4 ± 0.5
Bottom view
4.75 ± 0.1
The 10 mm spacing of the 2 pin
snap-in is used as the base layout
and a third hole is added.
The third hole is closer to the
negative primary hole so that
polarization is always maintained,
together with added mechanical
stability.
The negative terminal has TWO pins which are BOTH electrically
connected.
Fig. 4 - Three terminal snap-in
Fig. 5 - Mounting hole diagram
Table 1
DIMENSIONS in millimeters, MASS AND PACKAGING QUANTITIES
NOMINAL CASE
SIZE Ø D x L
Ø DMAX.
LMAX.
MASS
(g)
PACKAGING QUANTITIES
(units per box)
CARDBOARD BOX DIMENSIONS
LxWxH
22 x 25
23
27
 12
100
260 x 250 x 39
22 x 30
23
32
 16
100
260 x 250 x 44
22 x 35
23
37
 20
100
260 x 250 x 49
22 x 40
23
42
 23
100
260 x 250 x 54
25 x 30
26
32
 22
100
290 x 280 x 44
25 x 35
26
37
 24
100
290 x 280 x 49
25 x 40
26
42
 27
100
290 x 280 x 54
25 x 50
26
52
 38
100
290 x 280 x 64
30 x 30
31
32
 30
100
340 x 330 x 44
30 x 35
31
37
 35
100
340 x 330 x 49
30 x 40
31
42
 40
100
340 x 330 x 54
30 x 45
31
47
 45
100
340 x 330 x 59
30 x 50
31
52
 50
100
340 x 330 x 64
35 x 35
36
37
 48
50
390 x 198 x 49
35 x 40
36
42
 55
50
390 x 198 x 54
35 x 45
36
47
 63
50
390 x 198 x 59
35 x 50
36
52
 72
50
390 x 198 x 64
Revision: 20-May-15
Document Number: 28342
3
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
058/059 PLL-SI
www.vishay.com
Vishay BCcomponents
ORDERING EXAMPLE
ELECTRICAL DATA
SYMBOL
CR
IR
IL1
IL5
ESR
Z
Electrolytic capacitor 058 series
DESCRIPTION
Rated capacitance at 100 Hz
Rated RMS ripple current at 100 Hz
or  10 kHz and 105 °C
Max. leakage current after 1 min at UR
Max. leakage current after 5 min at UR
Max. equivalent series resistance at 100 Hz
Max. impedance at 10 kHz
10 000 μF / 25 V; ± 20 %
Nominal case size: Ø 30 mm x 40 mm
2-terminal snap-in:
Ordering code: MAL2 058 56103 E3
Former 12NC: 2222 058 56103
3-terminal snap-in:
Note
• Unless otherwise specified, all electrical values in Table 2 and 3
apply at Tamb = 20 °C, P = 86 kPa to 106 kPa, RH = 45 % to 75 %
Ordering code: MAL2 058 76103 E3 
Former 12NC: 2222 058 76103
Table 2
ELECTRICAL DATA AND ORDERING INFORMATION FOR 058 SERIES (Ø D x L in mm)
UR
(V)
10
16
25
40
CR
100 Hz
(μF)
4700
6800
10 000
10 000
15 000
15 000
22 000
22 000
33 000
33 000
47 000
3300
4700
6800
6800
10 000
10 000
15 000
15 000
22 000
22 000
33 000
2200
3300
4700
4700
6800
6800
10 000
10 000
15 000
15 000
22 000
1500
2200
3300
3300
4700
4700
6800
6800
10 000
10 000
15 000
Revision: 20-May-15
NOMINAL
CASE SIZE
ØDxL
(mm)
22 x 25
22 x 30
25 x 30
22 x 40
30 x 30
25 x 40
30 x 40
25 x 50
35 x 40
30 x 50
35 x 50
22 x 25
22 x 30
25 x 30
22 x 40
30 x 30
25 x 40
30 x 40
25 x 50
35 x 40
30 x 50
35 x 50
22 x 25
22 x 30
25 x 30
22 x 40
30 x 30
25 x 40
30 x 40
25 x 50
35 x 40
30 x 50
35 x 50
22 x 25
22 x 30
25 x 30
22 x 40
30 x 30
25 x 40
30 x 40
25 x 50
35 x 40
30 x 50
35 x 50
IR
100 Hz
105 °C
(A)
1.95
2.44
2.81
3.29
3.53
3.78
4.62
4.68
5.15
5.70
6.23
1.90
2.36
2.75
3.18
3.44
3.66
4.55
4.55
5.07
5.67
6.23
1.76
2.23
2.60
3.00
3.26
3.49
4.37
4.37
4.91
5.43
6.07
1.65
2.04
2.43
2.78
2.96
3.26
3.94
4.10
4.18
4.98
5.21
IR
 10 kHz
105 °C
(A)
2.30
2.88
3.32
3.88
4.17
4.46
5.45
5.52
6.08
6.73
7.35
2.24
2.78
3.25
3.75
4.06
4.32
5.37
5.37
5.98
6.69
7.35
2.08
2.63
3.07
3.54
3.85
4.12
5.16
5.16
5.79
6.41
7.16
2.01
2.49
2.99
3.39
3.61
3.90
4.81
5.00
5.10
6.08
6.36
ORDERING CODE
MAL2058.......
IL1
1 min
(μA)
IL5
5 min
(μA)
ESR
100 Hz
(m)
Z
10 kHz
(m)
2-TERM.
3-TERM.
286
412
604
604
904
904
1324
1324
1984
1984
2824
321
455
657
657
964
964
1444
1444
2116
2116
3172
334
499
709
709
1024
1024
1504
1504
2254
2254
3304
364
532
796
796
1132
1132
1636
1636
2404
2404
3604
98
140
204
204
304
304
444
444
664
664
944
110
154
222
222
324
324
484
484
708
708
1060
114
169
239
239
344
344
504
504
754
754
1104
124
180
268
268
380
380
548
548
804
804
1204
82
61
54
43
42
38
31
31
30
24
24
86
65
56
46
44
40
32
32
31
25
25
100
73
62
52
49
44
35
35
33
27
27
114
87
71
60
59
51
42
39
46
36
36
57
44
42
32
34
30
25
24
24
21
21
57
44
42
32
34
30
25
24
24
21
21
57
44
42
32
34
30
25
24
24
21
21
65
50
45
37
40
32
29
26
29
24
24
54472E3
54682E3
54103E3
44103E3
54153E3
44153E3
54223E3
44223E3
54333E3
44333E3
54473E3
55332E3
55472E3
55682E3
45682E3
55103E3
45103E3
55153E3
45153E3
55223E3
45223E3
55333E3
56222E3
56332E3
56472E3
46472E3
56682E3
46682E3
56103E3
46103E3
56153E3
46153E3
56223E3
57152E3
57222E3
57332E3
47332E3
57472E3
47472E3
57682E3
47682E3
57103E3
47103E3
57153E3
74472E3
74682E3
74103E3
24103E3
74153E3
24153E3
74223E3
24223E3
74333E3
24333E3
74473E3
75332E3
75472E3
75682E3
25682E3
75103E3
25103E3
75153E3
25153E3
75223E3
25223E3
75333E3
76222E3
76332E3
76472E3
26472E3
76682E3
26682E3
76103E3
26103E3
76153E3
26153E3
76223E3
77152E3
77222E3
77332E3
27332E3
77472E3
27472E3
77682E3
27682E3
77103E3
27103E3
77153E3
Document Number: 28342
4
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
058/059 PLL-SI
www.vishay.com
Vishay BCcomponents
ELECTRICAL DATA AND ORDERING INFORMATION FOR 058 SERIES (Ø D x L in mm)
CR
100 Hz
(μF)
UR
(V)
1000
1500
2200
2200
3300
3300
4700
4700
6800
6800
10 000
680
1000
1500
1500
2200
2200
3300
3300
4700
4700
6800
330
470
680
680
1000
1000
1500
1500
2200
2200
3300
50
63
100
NOMINAL
CASE SIZE
ØDxL
(mm)
22 x 25
22 x 30
25 x 30
22 x 40
30 x 30
25 x 40
30 x 40
25 x 50
35 x 40
30 x 50
35 x 50
22 x 25
22 x 30
25 x 30
22 x 40
30 x 30
25 x 40
30 x 40
25 x 50
35 x 40
30 x 50
35 x 50
22 x 25
22 x 30
25 x 30
22 x 40
30 x 30
25 x 40
30 x 40
25 x 50
35 x 40
30 x 50
35 x 50
IR
100 Hz
105 °C
(A)
1.50
1.88
2.27
2.55
2.81
3.07
3.77
3.85
4.01
4.74
5.04
1.17
1.46
1.76
2.00
2.27
2.40
3.07
3.07
3.65
3.88
4.58
0.92
1.14
1.35
1.57
1.79
1.85
2.45
2.38
3.05
3.13
3.84
IR
 10 kHz
105 °C
(A)
1.83
2.29
2.77
3.11
3.43
3.75
4.60
4.70
4.89
5.78
6.15
1.43
1.78
2.15
2.44
2.77
2.93
3.75
3.75
4.45
4.73
5.59
1.12
1.39
1.65
1.92
2.40
2.26
2.99
2.90
3.72
3.82
4.68
ORDERING CODE
MAL2058.......
IL1
1 min
(μA)
IL5
5 min
(μA)
ESR
100 Hz
(m)
Z
10 kHz
(m)
2-TERM.
3-TERM.
304
454
664
664
994
994
1414
1414
2044
2044
3004
261
382
571
571
836
836
1251
1251
1781
1781
2574
202
286
412
412
604
604
904
904
1324
1324
1984
104
154
124
124
334
334
474
474
684
684
1004
90
130
193
193
281
281
420
420
596
596
861
70
98
140
140
204
204
304
304
444
444
664
138
102
82
71
66
57
47
43
49
38
38
228
170
137
115
101
94
70
70
60
53
46
370
280
232
190
163
158
111
116
86
82
64
69
54
47
38
41
33
30
27
30
24
24
150
115
85
85
70
70
50
50
45
45
35
250
190
140
140
115
115
85
85
65
65
50
51102E3
51152E3
51222E3
41222E3
51332E3
41332E3
51472E3
41472E3
51682E3
41682E3
51103E3
58681E3
58102E3
58152E3
48152E3
58222E3
48222E3
58332E3
48332E3
58472E3
48472E3
58682E3
59331E3
59471E3
59681E3
49681E3
59102E3
49102E3
59152E3
49152E3
59222E3
49222E3
59332E3
71102E3
71152E3
71222E3
21222E3
71332E3
21332E3
71472E3
21472E3
71682E3
21682E3
71103E3
78681E3
78102E3
78152E3
28152E3
78222E3
28222E3
78332E3
28332E3
78472E3
28472E3
78682E3
79331E3
79471E3
79681E3
29681E3
79102E3
29102E3
79152E3
29152E3
79222E3
29222E3
79332E3
Table 3
ELECTRICAL DATA AND ORDERING INFORMATION FOR 059 SERIES
UR
(V)
200
250
CR
100 Hz
(μF)
100
150
220
220
330
330
470
470
680
680
1000
68
100
150
150
220
220
330
330
470
470
680
Revision: 20-May-15
NOMINAL
CASE SIZE
ØDxL
(mm)
22 x 25
22 x 30
22 x 35
25 x 30
30 x 30
25 x 40
30 x 35
25 x 50
30 x 45
35 x 35
35 x 50
22 x 25
22 x 30
22 x 35
25 x 30
25 x 35
30 x 30
30 x 35
25 x 50
30 x 45
35 x 35
35 x 45
IR
100 Hz
105 °C
(A)
0.53
0.67
0.86
0.87
1.12
1.12
1.46
1.25
1.87
1.85
2.45
0.49
0.62
0.82
0.82
1.03
1.06
1.43
1.40
1.79
1.79
2.25
ORDERING CODE
MAL2059.....
IL1
1 min
(μA)
IL5
5 min
(μA)
ESR
100 Hz
(m)
Z
10 kHz
(m)
2-TERM.
3-TERM.
124
184
268
268
400
400
568
568
820
820
1204
106
154
229
229
334
334
499
499
709
709
1024
44
64
92
92
136
136
192
192
276
276
404
38
54
79
79
114
114
169
169
239
239
344
1280
850
610
610
435
435
335
335
235
235
160
1640
1110
795
795
540
540
385
385
270
270
190
730
540
430
430
300
300
225
225
155
155
125
760
570
440
440
300
300
225
225
155
155
125
52101E3
52151E3
32221E3
52221E3
52331E3
42331E3
32471E3
42471E3
32681E3
62681E3
52102E3
53689E3
53101E3
33151E3
53151E3
33221E3
53221E3
33331E3
43331E3
33471E3
63471E3
43681E3
72101E3
72151E3
12221E3
72221E3
72331E3
22331E3
12471E3
22471E3
12681E3
82681E3
72102E3
73689E3
73101E3
13151E3
73151E3
13221E3
73221E3
13331E3
23331E3
13471E3
83471E3
23681E3
Document Number: 28342
5
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
058/059 PLL-SI
www.vishay.com
Vishay BCcomponents
ELECTRICAL DATA AND ORDERING INFORMATION FOR 059 SERIES
CR
100 Hz
(μF)
UR
(V)
33
47
68
68
100
100
150
150
220
220
330
47
68
68
100
100
150
150
220
220
330
385
400
IR
100 Hz
105 °C
(A)
0.32
0.41
0.53
0.52
0.72
0.72
0.99
0.99
1.31
1.31
1.75
0.30
0.38
0.41
0.55
0.55
0.68
0.78
0.94
0.94
1.25
NOMINAL
CASE SIZE
ØDxL
(mm)
22 x 25
22 x 30
22 x 35
25 x 30
30 x 30
25 x 40
30 x 40
25 x 50
35 x 40
30 x 50
35 x 50
22 x 30
22 x 35
25 x 30
30 x 30
25 x 40
30 x 35
25 x 50
35 x 40
30 x 50
35 x 50
ORDERING CODE
MAL2059.....
IL1
1 min
(μA)
IL5
5 min
(μA)
ESR
100 Hz
(m)
Z
10 kHz
(m)
2-TERM.
3-TERM.
80
113
161
161
235
235
351
351
512
512
766
117
167
167
244
244
364
364
532
532
796
29
40
56
56
81
81
119
119
173
173
258
42
58
58
84
84
124
124
180
180
260
3860
2710
1870
1870
1270
1270
850
850
580
580
390
4260
2950
2950
2020
2020
1350
1350
930
930
620
3000
2100
1460
1460
1010
1010
675
675
465
465
320
3490
2420
2420
1660
1660
1110
1110
760
760
510
58339E3
58479E3
38689E3
58689E3
58101E3
48101E3
58151E3
48151E3
58221E3
48221E3
58331E3
56479E3
36689E3
56689E3
56101E3
46101E3
36151E3
46151E3
56221E3
46221E3
56331E3
78339E3
78479E3
18689E3
78689E3
78101E3
28101E3
78151E3
28151E3
78221E3
28221E3
78331E3
76479E3
16689E3
76689E3
76101E3
26101E3
16151E3
26151E3
76221E3
26221E3
76331E3
ADDITIONAL ELECTRICAL DATA
PARAMETER
Voltage
Surge voltage
CONDITIONS
VALUE
 250 V versions
 385 V versions
Us = 1.15 x UR
Us = 1.1 x UR
Urev  1 V
After 1 min at UR
After 5 min at UR
IL1  0.006 CR x UR + 4 μA
IL5  0.002 CR x UR + 4 μA
All case sizes
Typ. 19 nH
Max. 25 nH
Reverse voltage
Current
Leakage current
Inductance
Equivalent series inductance (ESL)
CAPACITANCE (C)
1.1
1.1
C
C0
C
C0
1.0
1.0
0.9
0.8
3
0.9
1
2
2
0.7
0.8
3
0.6
0.5
Curve 1: UR = 63 to 100 V
Curve 2: UR = 200 V
Curve 3: UR ≥ 250 V and ≤ 40 V
C0 = capacitance at 20 °C and 100 Hz
0.4
- 100
- 50
0
50
0.7
1
C0 = capacitance at 20 °C and 100 Hz
100
150
Tamb (°C)
Fig. 6 - Typical multiplier of capacitance as a function of
ambient temperature
Revision: 20-May-15
Curve 1: UR = 10 V and 16 V
Curve 2: UR = 25 V, 35 V and 40 V
Curve 3: UR ≥ 40 V
0.6
101
102
103
f (Hz)
104
Fig. 7 - Typical multiplier of capacitance as a function of frequency
Document Number: 28342
6
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
058/059 PLL-SI
www.vishay.com
Vishay BCcomponents
EQUIVALENT SERIES RESISTANCE (ESR)
10
3
ESR
ESR0
1.5
10
ESR
ESR0
Curve 1: UR ≥ 250 V
Curve 2: UR = 200 V
Curve 3: UR ≤ 200 V
1
2
2
1.0
3
2
101
1
0.5
1
2, 3
1
ESR0 = typical at 20 °C and 100 Hz
10-1
- 100
- 50
0
Curve 1: UR = 10 to 100 V
Curve 2: UR = 200 to 400 V
ESR0 = typical at 20 °C and 100 Hz
50
100
0
101
150
102
103
Tamb (°C)
Fig. 8 - Typical multiplier of ESR as a function of
ambient temperature
f (Hz)
104
Fig. 9 - Typical multiplier of ESR as a function of frequency
IMPEDANCE (Z)
103
105
ESR
ESR0
102
Z
(mΩ)
Curve 1: UR ≥ 250 V
Curve 2: UR = 250 V
Curve 3: UR ≤ 100 V
1
Curve 1: 47 µF
Curve 2: 100 µF
Curve 3: 150 µF
Curve 4: 470 µF
Curve 5: 1000 µF
1
104
2
3
Curve 6: 1500 µF
Curve 7: 2200 µF
Curve 8: 3300 µF
Curve 9: 4700 µF
Curve 10: 6800 µF
2
4
3
101
103
1
102
2, 3
1
Z0 = typical impedance at 20 °C and 100 Hz
10-1
- 100
- 50
0
50
5
6
7
8
9
10
Tamb = 20 °C
Case Ø D x L = 22 x 30 mm
100
150
101 1
10
10
2
10
3
10
4
10
5
106
Tamb (°C)
105
Curve 1: 33 µF
Curve 2: 68 µF
Curve 3: 100 µF
Curve 4: 330 µF
Curve 5: 680 µF
1
Z
(mΩ)
2
3
10
107
Fig. 12 - Typical impedance as a function of frequency
Fig. 10 - Typical multiplier of impedance as a function
of ambient temperature
105
f (Hz)
4
Curve 6: 1000 µF
Curve 7: 1500 µF
Curve 8: 2200 µF
Curve 9: 3300 µF
Curve 10: 4700 µF
Z
(mΩ)
Curve 1: 68 µF
Curve 2: 150 µF
Curve 3: 220 µF
Curve 4: 680 µF
Curve 5: 1500 µF
Curve 6: 2200 µF
Curve 7: 3300 µF
Curve 8: 4700 µF
Curve 9: 6800 µF
Curve 10: 10 000 µF
Case Ø D x L = 25 x 30 mm and 22 x 40 mm
Tamb = 20 °C
1
104
2
3
4
10
3
5
6
7
8
9
10
4
10
102
5
6
7
8
9
10
102
Tamb = 20 °C
Case Ø D x L = 22 x 25 mm
101 1
10
3
102
103
104
105
106
f (Hz)
107
Fig. 11 - Typical impedance as a function of frequency
Revision: 20-May-15
101 1
10
102
103
104
105
106
f (Hz)
107
Fig. 13 - Typical impedance as a function of frequency
Document Number: 28342
7
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
058/059 PLL-SI
www.vishay.com
Vishay BCcomponents
IMPEDANCE (Z)
105
105
Curve 1: 100 µF
Curve 2: 220 µF
Curve 3: 330 µF
Curve 4: 1000 µF
Curve 5: 2200 µF
Z
(mΩ)
104
1
Curve 6: 3300 µF
Curve 7: 4700 µF
Curve 8: 6800 µF
Curve 9: 10 000 µF
Curve 10: 15 000 µF
Curve 1: 220 µF
Curve 2: 470 µF
Curve 3: 680 µF
Curve 4: 2200 µF
Curve 5: 4700 µF
Z
(mΩ)
104
1
2
3
2
3
103
102
101 1
10
4
4
5
6
7
8
9
10
102
Tamb = 20 °C
Case Ø D x L = 30 x 30 mm and 25 x 40 mm
102
103
104
105
106
f (Hz)
107
105
101 1
10
1
Curve 6: 4700 µF
Curve 7: 6800 µF
Curve 8: 10 000 µF
Curve 9: 15 000 µF
Curve 10: 22 000 µF
101 1
10
103
104
105
104
106
f (Hz)
107
Curve 6: 10 000 µF
Curve 7: 15 000 µF
Curve 8: 22 000 µF
Curve 9: 33 000 µF
Curve 10: 47 000 µF
1
2
3
Case Ø D x L = 35 x 50 mm
103
4
4
5
6
7
8
9
10
10
Tamb = 20 °C
10
Curve 1: 330 µF
Curve 2: 680 µF
Curve 3: 1000 µF
Curve 4: 3300 µF
Curve 5: 6800 µF
Z
(mΩ)
Case Ø D x L = 30 x 40 mm and 25 x 50 mm
10
Tamb = 20 °C
102
Fig. 16 - Typical impedance as a function of frequency
2
3
2
5
6
7
8
9
10
105
Curve 1: 150 µF
Curve 2: 330 µF
Curve 3: 470 µF
Curve 4: 1500 µF
Curve 5: 3300 µF
Z
(mΩ)
103
Case Ø D x L = 35 x 40 mm and 30 x 50 mm
103
Fig. 14 - Typical impedance as a function of frequency
104
Curve 6: 6800 µF
Curve 7: 10 000 µF
Curve 8: 15 000 µF
Curve 9: 22 000 µF
Curve 10: 33 000 µF
2
10
3
10
4
10
5
10
6
f (Hz)
10
7
Fig. 15 - Typical impedance as a function of frequency
Revision: 20-May-15
2
101 1
10
5
6
7
8
9
10
Tamb = 20 °C
10
2
10
3
10
4
10
5
106
f (Hz)
107
Fig. 17 - Typical impedance as a function of frequency
Document Number: 28342
8
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
058/059 PLL-SI
www.vishay.com
Vishay BCcomponents
RIPPLE CURRENT AND USEFUL LIFE
MGA454
2.7
IA
IR
2.6
2.5
2.4
2.3
2.2
2.1
2.0
1.9
2
1
2
1. 5
1.
1.8
Life multiplier
5
2.
3
1.7
4
5
1.6
7
IA = Actual ripple current at 100 Hz
IR = Rated ripple current at 100 Hz and 105 °C
(1)
20
30
40
60 0
10 0
15 0
20 0
30 0
40 0
60
1.4
1.3
10
15
1.5
1.2
1.1
1.0
0.8
0.5
0.0
40
Useful life at 105 °C and IR applied:
5000 h for ≤ 50 V types
10 000 h for ≥ 63 V types
50
60
(1)
70
80
90
100
110
Tamb (°C)
Fig. 18 - Multiplier of useful life as a function of ambient temperature and ripple current load
Table 4
MULTIPLIER OF RIPPLE CURRENT (IR) AS A FUNCTION OF FREQUENCY
IR MULTIPLIER
FREQUENCY
(Hz)
UR = 10 V TO 25 V
UR = 40 V TO 100 V
UR > 100 V
50
0.93
0.91
0.86
100
1.00
1.00
1.00
200
1.04
1.05
1.13
400
1.07
1.09
1.21
1000
1.11
1.13
1.29
2000
1.13
1.15
1.32
4000
1.15
1.18
1.35
10 000
1.18
1.22
1.40
Revision: 20-May-15
Document Number: 28342
9
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
058/059 PLL-SI
www.vishay.com
Vishay BCcomponents
Table 5
TEST PROCEDURES AND REQUIREMENTS
TEST
NAME OF TEST
REFERENCE
PROCEDURE
(quick reference)
REQUIREMENTS
UR  100 V; C/C: ± 15 %
Endurance
IEC 60384-4 / 
EN 130300
subclause 4.13
Tamb = 105 °C; UR applied;
50 V types: 2000 h;
63 V types: 5000 h
UR  100 V; C/C: ± 10 %
ESR  1.3 x spec. limit
Z  2 x spec. limit
IL5  spec. limit
UR  100 V; C/C: ± 45 %
UR > 100 V; C/C: ± 30 %
ESR  3 x spec. limit
Useful life
CECC 30301
subclause 1.8.1
Tamb = 105 C; UR and IR applied;
 50 V types: 5000 h;
63 V types: 10 000 h
Z 3 x spec. limit
IL5  spec. limit
no short or open circuit,
no visible damage
total failure percentage;
UR > 100 V:  3 %
Shelf life
(storage at
high temperature)
Revision: 20-May-15
IEC 60384-4 / 
EN 130300
subclause 4.17
Tamb = 105 C; no voltage applied;
500 h
C/C: ± 10 %
After test: UR to be applied for 30 min
24 h to 48 h before measurement
IL5  2 x spec. limit
ESR  1.2 x spec. limit
Document Number: 28342
10
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please
contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Material Category Policy
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the
definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council
of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment
(EEE) - recast, unless otherwise specified as non-compliant.
Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that
all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free
requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference
to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21
conform to JEDEC JS709A standards.
Revision: 02-Oct-12
1
Document Number: 91000