056/057 PSM-SI www.vishay.com Vishay BCcomponents Aluminum Capacitors Power Standard Miniature Snap-In FEATURES • Polarized aluminum electrolytic capacitors, non-solid electrolyte • Large types, minimized dimensions, cylindrical aluminum case, insulated with a blue sleeve • Pressure relief on the top of the aluminum case • Charge and discharge proof • Long useful life: 12 000 h at 85 °C • High ripple current capability 156/157 PUM-SI • Keyed polarity version available • Material categorization: For definitions please see www.vishay.com/doc?99912 smaller dimensions long life 105 °C 056/057 PSM-SI 058/059 PLL-SI APPLICATIONS • General purpose, industrial and audio/video systems Fig. 1 • Smoothing and filtering • Standard and switched mode power supplies QUICK REFERENCE DATA • Energy storage in pulse systems VALUE DESCRIPTION 056 Nominal case size (Ø D x L in mm) 057 MARKING 22 x 25 to 35 x 50 Rated capacitance range (E6 series), CR 470 μF to 68 000 μF Tolerance on CR 47 μF to 1500 μF ± 20 % Rated voltage range, UR (1) 10 V to 100 V 200 V to 450 V The capacitors are marked (where possible) with the following information: • Rated capacitance (in μF) • Tolerance code on rated capacitance, code letter in accordance with IEC 60062 (M for ± 20 %) Category temperature range - 25 °C to + 85 °C - 25 °C to + 85 °C • Rated voltage (in V) Endurance test at 85 °C • Date code (YYMM or in 2 digits according to IEC 60062) 5000 h (450 V: 2000 h) Useful life at 85 °C 12 000 h (450 V: 5000 h) • Name of manufacturer Useful life at 40 °C and 1.4 x IR applied 210 000 h (450 V: 90 000 h) Shelf life at 0 V, 85 °C 500 h Based on sectional specification • ‘-’ sign to identify the negative terminal, visible from the top and side of the capacitor IEC 60384-4/EN130300 Climatic category IEC 60068 40/085/056 • Code for factory of origin • Code number 25/085/56 • Climatic category in accordance with IEC 60068 Note (1) A 420 V range is available on request SELECTION CHART FOR CR, UR, AND RELEVANT NOMINAL CASE SIZES FOR 056 SERIES (Ø D x L in mm) UR (V) CR (μF) 10 16 25 40 50 63 100 470 - - - - - - 22 x 25 680 - - - - - - 22 x 30 - - - - - 22 x 25 25 x 30 - - - - - - 22 x 40 - - - - 22 x 25 22 x 30 30 x 30 - - - - - - 25 x 40 - - - 22 x 25 22 x 30 25 x 30 30 x 40 - - - - - 22 x 40 25 x 50 1000 1500 2200 Revision: 09-Mar-12 Document Number: 28340 1 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 056/057 PSM-SI www.vishay.com Vishay BCcomponents SELECTION CHART FOR CR, UR, AND RELEVANT NOMINAL CASE SIZES FOR 056 SERIES (Ø D x L in mm) CR (μF) 3300 4700 6800 10 000 15 000 22 000 33 000 47 000 68 000 UR (V) 10 16 25 40 50 63 100 - - 22 x 25 22 x 30 25 x 30 30 x 30 35 x 40 - - - - 22 x 40 25 x 40 30 x 50 - 22 x 25 22 x 30 25 x 30 30 x 30 30 x 40 35 x 50 - - - 22 x 40 25 x 40 25 x 50 - 22 x 25 22 x 30 25 x 30 30 x 30 30 x 40 35 x 40 - - - 22 x 40 25 x 40 25 x 50 30 x 50 - 22 x 30 25 x 30 30 x 30 30 x 40 35 x 40 35 x 50 - - 22 x 40 25 x 40 25 x 50 30 x 50 - - 25 x 30 30 x 30 30 x 40 35 x 40 35 x 50 - - 22 x 40 25 x 40 25 x 50 30 x 50 - - - 30 x 30 30 x 40 35 x 40 35 x 50 - - - 25 x 40 25 x 50 30 x 50 - - - - 30 x 40 35 x 40 35 x 50 - - - - 25 x 50 30 x 50 - - - - - 35 x 40 35 x 50 - - - - - 30 x 50 - - - - - - 35 x 50 - - - - - - SELECTION CHART FOR CR, UR, AND RELEVANT NOMINAL CASE SIZES FOR 057 SERIES (Ø D x L in mm) UR (V) CR (μF) 200 250 385 400 450 47 - - 22 x 25 22 x 25 22 x 30 68 - - 22 x 30 22 x 30 22 x 30 - 22 x 25 25 x 30 25 x 30 30 x 30 - - 22 x 40 22 x 35 25 x 35 - - 22 x 35 - - 22 x 25 22 x 30 30 x 30 30 x 30 25 x 50 - - 25 x 40 - 30 x 35 - - - 25 x 40 - 22 x 30 25 x 30 30 x 45 30 x 35 35 x 40 - 22 x 40 30 x 40 25 x 40 30 x 45 - - 30 x 35 - - 100 150 220 330 470 680 1000 1500 Revision: 09-Mar-12 - - 25 x 50 - - 25 x 30 30 x 30 35 x 35 35 x 40 35 x 50 22 x 40 25 x 40 - 35 x 50 35 x 45 30 x 30 30 x 40 35 x 50 35 x 50 - 25 x 40 25 x 50 35 x 45 - - 30 x 40 35 x 40 - - - 25 x 50 30 x 50 - - - 35 x 40 35 x 50 - - - 30 x 50 - - - - 35 x 50 - - - - Document Number: 28340 2 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 056/057 PSM-SI www.vishay.com Vishay BCcomponents DIMENSIONS in millimeters AND AVAILABLE FORMS TWO TERMINAL SNAP-IN ØD + TERMINAL L 10 ± 0.1 L + 2 max. - TERMINAL 5.8 +- 01 mm Bottom view Ø 2 ± 0.1 (2 x) The minus terminal can be marked with a black dot or with an imprinted “-” sign. Fig. 2 - Two terminal snap-in Fig. 3 - Mounting hole diagram THREE TERMINAL SNAP-IN ØD Ø 2 ± 0.1 (2 x) Ø 2.5 ± 0.1 + TERMINAL L ± 2 max. L - TERMINAL minus pole marking 3.3 ± 0.1 4 ± 0.5 Bottom view 4.75 ± 0.1 The negative terminal has TWO pins which are BOTH electrically connected. Fig. 4 - Three terminal snap-in The 10 mm spacing of the 2 pin snap-in is used as the base layout 10 ± 0.1 and a third hole is added. The third hole is closer to the negative primary hole so that polarization is always maintained, together with added mechanical stability. Fig. 5 - Mounting hole diagram Table 1 DIMENSIONS in millimeters, MASS AND PACKAGING QUANTITIES NOMINAL CASE SIZE Ø D x L Ø Dmax. Lmax. MASS (g) PACKAGING QUANTITIES (units per box) CARDBOARD BOX DIMENSIONS LxWxH (mm) 22 x 25 23 27 12 100 260 x 250 x 39 22 x 30 23 32 16 100 260 x 250 x 44 22 x 35 23 37 20 100 260 x 250 x 49 22 x 40 23 42 23 100 260 x 250 x 54 25 x 30 26 32 22 100 290 x 280 x 44 25 x 35 26 37 24 100 290 x 280 x 49 25 x 40 26 42 27 100 290 x 280 x 54 25 x 50 26 52 38 100 290 x 280 x 64 30 x 30 31 32 30 100 340 x 330 x 44 30 x 35 31 37 35 100 340 x 330 x 49 30 x 40 31 42 40 100 340 x 330 x 54 30 x 45 31 47 45 100 340 x 330 x 59 30 x 50 31 52 50 100 340 x 330 x 64 35 x 35 36 37 48 50 390 x 198 x 49 35 x 40 36 42 55 50 390 x 198 x 54 35 x 45 36 47 63 50 390 x 198 x 59 35 x 50 36 52 72 50 390 x 198 x 64 Revision: 09-Mar-12 Document Number: 28340 3 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 056/057 PSM-SI www.vishay.com Vishay BCcomponents ORDERING EXAMPLE ELECTRICAL DATA SYMBOL Electrolytic capacitor 056 series DESCRIPTION 10 000 μF/25 V; ± 20 % CR Rated capacitance at 100 Hz IR Rated RMS ripple current at 100 Hz or 10 kHz and 85 °C Nominal case size: Ø 25 mm x 40 mm IL1 Max. leakage current after 1 min at UR IL5 Max. leakage current after 5 min at UR Ordering code: MAL2 05646103E3 Former 12NC: 2222 05646103 Max. equivalent series resistance at 100 Hz 3-terminal snap-in: ESR Z 2-terminal snap-in: Max. impedance at 10 kHz Note • Unless otherwise specified, all electrical values in Tables 2 and 3 apply at Tamb = 20 °C, P = 86 kPa to 106 kPa, RH = 45 % to 75 % Ordering code: MAL2 05626103E3 Former 12NC: 2222 05626103 Table 2 ELECTRICAL DATA AND ORDERING INFORMATION FOR 056 SERIES UR (V) 10 16 25 ORDERING CODE MAL2056....... CR 100 Hz (μF) NOMINAL CASE SIZE ØDxL (mm) IR 100 Hz 85 °C (A) IR 10 kHz 85 °C (A) IL1 1 min (μA) IL5 5 min (μA) ESR 100 Hz (m) Z 10 kHz (m) 2-TERM. 3-TERM. 6800 10 000 15 000 15 000 22 000 22 000 33 000 33 000 47 000 47 000 68 000 4700 6800 10 000 10 000 15 000 15 000 22 000 22 000 33 000 33 000 47 000 3300 4700 6800 6800 10 000 10 000 15 000 15 000 22 000 22 000 33 000 22 x 25 22 x 30 25 x 30 22 x 40 30 x 30 25 x 40 30 x 40 25 x 50 35 x 40 30 x 50 35 x 50 22 x 25 22 x 30 25 x 30 22 x 40 30 x 30 25 x 40 30 x 40 25 x 50 35 x 40 30 x 50 35 x 50 22 x 25 22 x 30 25 x 30 22 x 40 30 x 30 25 x 40 30 x 40 25 x 50 35 x 40 30 x 50 35 x 50 2.04 2.56 3.12 3.39 3.47 4.12 4.58 4.70 5.10 5.39 5.88 2.01 2.54 3.02 3.28 3.36 4.00 4.51 3.97 5.02 4.75 5.34 1.88 2.37 2.81 3.16 3.25 3.73 4.73 3.92 4.48 4.96 4.98 2.40 3.02 3.68 4.00 4.09 4.86 5.40 5.55 6.02 6.36 6.94 2.37 3.00 3.56 3.87 3.96 4.72 5.32 4.68 5.92 5.61 6.30 2.22 2.80 3.32 3.73 3.84 4.40 5.58 4.63 5.29 5.85 5.88 412 608 904 904 1324 1324 1984 1984 2824 2824 4084 455 657 964 964 1444 1444 2116 2116 3172 3172 4516 499 709 1024 1024 1504 1504 2254 2254 3304 3304 4954 140 205 304 304 444 444 664 664 944 944 1364 154 222 324 324 484 484 708 708 1060 1060 1508 169 239 344 344 504 504 754 754 1104 1104 1654 76 56 44 41 44 34 32 30 31 28 28 79 57 47 44 47 34 33 42 32 36 34 89 65 54 47 50 39 30 43 40 36 39 62 45 39 34 37 28 28 27 26 24 23 62 45 39 34 37 28 28 41 28 34 32 61 45 41 38 38 30 28 39 28 23 33 54682E3 54103E3 54153E3 44153E3 54223E3 44223E3 54333E3 44333E3 54473E3 44473E3 54683E3 55472E3 55682E3 55103E3 45103E3 55153E3 45153E3 55223E3 45223E3 55333E3 45333E3 55473E3 56332E3 56472E3 56682E3 46682E3 56103E3 46103E3 56153E3 46153E3 56223E3 46223E3 56333E3 74682E3 74103E3 74153E3 24153E3 74223E3 24223E3 74333E3 24333E3 74473E3 24473E3 74683E3 75472E3 75682E3 75103E3 25103E3 75153E3 25153E3 75223E3 25223E3 75333E3 25333E3 75473E3 76332E3 76472E3 76682E3 26682E3 76103E3 26103E3 76153E3 26153E3 76223E3 26223E3 76333E3 Revision: 09-Mar-12 Document Number: 28340 4 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 056/057 PSM-SI www.vishay.com Vishay BCcomponents ELECTRICAL DATA AND ORDERING INFORMATION FOR 056 SERIES UR (V) 40 50 63 100 CR 100 Hz (μF) NOMINAL CASE SIZE ØDxL (mm) IR 100 Hz 85 °C (A) IR 10 kHz 85 °C (A) IL1 1 min (μA) IL5 5 min (μA) ESR 100 Hz (m) Z 10 kHz (m) 2-TERM. 3-TERM. 2200 22 x 25 1.85 2.26 532 180 92 61 57222E3 77222E3 3300 22 x 30 2.09 2.55 796 260 67 45 57332E3 77332E3 4700 25 x 30 2.28 2.78 1132 380 82 70 57472E3 77472E3 4700 22 x 40 3.10 3.78 1132 380 49 38 47472E3 27472E3 6800 30 x 30 3.16 3.85 1636 548 53 38 57682E3 77682E3 6800 25 x 40 3.06 3.73 1636 548 58 50 47682E3 27682E3 10 000 30 x 40 4.20 5.12 2404 804 38 28 57103E3 77103E3 10 000 25 x 50 3.88 4.73 2404 804 44 39 47103E3 27103E3 15 000 35 x 40 4.05 4.94 3604 1204 49 41 57153E3 77153E3 15 000 30 x 50 4.45 5.43 3604 1204 41 34 47153E3 27153E3 22 000 35 x 50 4.86 5.93 5284 1764 40 33 57223E3 77223E3 1500 22 x 25 1.36 1.66 454 154 170 130 51152E3 71152E3 2200 22 x 30 1.75 2.14 664 224 120 91 51222E3 71222E3 3300 25 x 30 2.17 2.65 994 334 90 72 51332E3 71332E3 3300 22 x 40 2.42 2.95 994 334 80 63 41332E3 21332E3 4700 30 x 30 2.65 3.23 1414 474 75 63 51472E3 71472E3 4700 25 x 40 2.89 3.53 1414 474 65 52 41472E3 21472E3 6800 30 x 40 3.56 4.34 2044 684 53 45 51682E3 71682E3 6800 25 x 50 3.75 4.58 2044 684 50 43 41682E3 21682E3 10 000 35 x 40 4.05 4.94 3004 1004 49 42 51103E3 71103E3 10 000 30 x 50 4.50 5.49 3004 1004 40 35 41103E3 21103E3 15 000 35 x 50 4.98 6.08 4504 1504 39 33 51153E3 71153E3 1000 22 x 25 1.46 1.78 382 130 148 104 58102E3 78102E3 1500 22 x 30 1.87 2.28 571 193 105 72 58152E3 78152E3 2200 25 x 30 2.32 2.83 836 281 79 59 58222E3 78222E3 2200 22 x 40 2.54 3.10 836 281 73 53 48222E3 28222E3 3300 30 x 30 2.87 3.50 1251 420 64 50 58332E3 78332E3 3300 25 x 40 3.14 3.83 1251 420 55 44 48332E3 28332E3 4700 30 x 40 3.67 4.48 1780 596 50 38 58472E3 78472E3 4700 25 x 50 3.71 4.53 1780 596 48 38 48472E3 28472E3 6800 35 x 40 4.33 5.28 2574 861 43 38 58682E3 78682E3 28682E3 ORDERING CODE MAL2056....... 6800 30 x 50 4.75 5.80 2574 861 42 37 48682E3 10 000 35 x 50 5.26 6.42 3784 1264 35 30 58103E3 78103E3 470 22 x 25 0.77 0.94 286 98 535 470 59471E3 79471E3 680 22 x 30 0.99 1.21 412 160 375 328 59681E3 79681E3 1000 25 x 30 1.27 1.55 604 204 265 235 59102E3 79102E3 1000 22 x 40 1.35 1.65 604 204 260 225 49102E3 29102E3 1500 30 x 30 1.67 2.04 904 304 190 170 59152E3 79152E3 1500 25 x 40 1.75 2.14 904 304 180 160 49152E3 29152E3 2200 30 x 40 2.27 2.77 1324 444 130 120 59222E3 79222E3 2200 25 x 50 2.30 2.80 1324 444 125 110 49222E3 29222E3 3300 35 x 40 2.84 3.46 1984 664 100 95 59332E3 79332E3 3300 30 x 50 2.97 3.62 1984 664 92 85 49332E3 29332E3 4700 35 x 50 3.59 4.38 2824 677 75 70 59472E3 79472E3 Revision: 09-Mar-12 Document Number: 28340 5 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 056/057 PSM-SI www.vishay.com Vishay BCcomponents Table 3 ELECTRICAL DATA AND ORDERING INFORMATION FOR 057 SERIES UR (V) 200 250 385 400 450 NOMINAL CR CASE SIZE ØDXL 100 Hz (μF) (mm) 150 220 330 330 470 470 680 680 1000 1000 1500 100 150 220 220 330 330 470 470 680 680 1000 47 68 100 100 100 150 150 220 220 220 330 330 470 470 47 68 100 100 150 150 220 220 330 330 470 47 68 100 100 150 150 220 220 330 330 Revision: 09-Mar-12 22 x 25 22 x 30 25 x 30 22 x 40 30 x 30 25 x 40 30 x 40 25 x 50 35 x 40 30 x 50 35 x 50 22 x 25 22 x 30 25 x 30 22 x 40 30 x 30 25 x 40 30 x 40 25 x 50 35 x 40 30 x 50 35 x 50 22 x 25 22 x 30 25 x 30 22 x 40 22 x 35 30 x 30 25 x 40 30 x 40 30 x 35 25 x 50 35 x 35 30 x 45 35 x 50 35 x 45 22 x 25 22 x 30 25 x 30 22 x 35 30 x 30 25 x 40 30 x 35 25 x 50 35 x 40 30 x 50 35 x 50 22 x 30 22 x 30 30 x 30 25 x 35 30 x 35 25 x 50 35 x 40 30 x 45 35 x 50 35 x 45 IR 100 Hz 85 °C (A) 0.77 1.00 1.36 1.36 1.80 1.80 2.39 2.39 2.85 2.85 3.66 0.63 0.83 1.10 1.10 1.49 1.49 1.98 1.98 2.60 2.60 3.12 0.50 0.63 0.86 0.86 0.84 1.16 1.16 1.57 1.50 1.57 1.73 1.75 2.40 2.29 0.50 0.63 0.86 0.84 1.16 1.16 1.50 1.57 1.85 1.85 2.40 0.26 0.33 0.48 0.46 0.66 0.70 0.92 0.73 1.26 1.20 ORDERING CODE MAL2057....... IL1 1 min (μA) IL5 5 min (μA) ESR 100 Hz (m) Z 10 kHz (m) 2-TERM. 3-TERM. 184 268 400 400 568 568 820 820 1204 1204 1804 154 229 334 334 499 499 709 709 1024 1024 1504 112 161 235 235 235 350 350 512 512 512 766 766 1089 1089 117 167 244 240 364 364 532 532 796 796 1132 131 188 274 274 409 409 598 598 895 895 64 92 136 136 192 192 276 276 404 404 604 54 79 114 114 169 169 239 239 344 344 504 40 56 81 81 81 119 119 173 173 173 258 258 366 366 42 58 84 84 124 124 180 180 268 268 380 45 65 94 94 140 140 202 202 301 301 950 650 430 430 310 310 210 210 160 160 120 1440 960 660 660 440 440 310 310 240 240 160 3000 2100 1400 1400 1400 950 950 650 650 650 480 480 340 340 3000 2100 1400 1400 950 950 650 650 480 480 340 5600 3900 2600 2600 1600 1600 1100 1100 700 700 620 435 310 310 230 230 180 180 135 135 105 770 520 365 365 265 265 185 185 145 145 105 1400 1000 780 780 780 520 520 400 400 400 280 280 220 220 1400 1000 780 780 520 520 400 400 280 280 220 4400 3100 2100 2100 1300 1300 900 900 600 600 52151E3 52221E3 52331E3 42331E3 52471E3 42471E3 52681E3 42681E3 52102E3 42102E3 52152E3 53101E3 53151E3 53221E3 43221E3 53331E3 43331E3 53471E3 43471E3 53681E3 43681E3 53102E3 58479E3 58689E3 58101E3 48101E3 38101E3 58151E3 48151E3 58221E3 38221E3 48221E3 68331E3 38331E3 58471E3 48471E3 56479E3 56689E3 56101E3 36101E3 56151E3 46151E3 36221E3 46221E3 56331E3 46331E3 56471E3 67479E3 57689E3 57101E3 37101E3 37151E3 47151E3 57221E3 37221E3 57331E3 47331E3 72151E3 72221E3 72331E3 22331E3 72471E3 22471E3 72681E3 22681E3 72102E3 22102E3 72152E3 73101E3 73151E3 73221E3 23221E3 73331E3 23331E3 73471E3 23471E3 73681E3 23681E3 73102E3 78479E3 68689E3 78101E3 68101E3 88101E3 78151E3 68151E3 78221E3 90051E3 68221E3 88331E3 78331E3 78471E3 28471E3 76479E3 76689E3 76101E3 66101E3 90054E3 86151E3 90055E3 86221E3 76331E3 26331E3 76471E3 87479E3 77689E3 77101E3 17101E3 17151E3 27151E3 77221E3 17221E3 77331E3 27331E3 Document Number: 28340 6 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 056/057 PSM-SI www.vishay.com Vishay BCcomponents ADDITIONAL ELECTRICAL DATA PARAMETER CONDITIONS VALUE 250 V versions Us = 1.15 x UR 385 V versions Us = 1.1 x UR Voltage Surge voltage Urev 1 V Reverse voltage Current Leakage current after 1 min at UR IL1 0.006 CR x UR + 4 μA after 5 min at UR IL5 0.002 CR x UR + 4 μA Inductance Equivalent series inductance (ESL) typ. 19 nH all case sizes CAPACITANCE (C) max. 25 nH EQUIVALENT SERIES RESISTANCE (ESR) 1.2 ESR ESR0 C C0 Curve 1: UR ≥ 250 V Curve 2: UR = 200 V Curve 3: UR ≤ 100 V 1 1.1 10 1 2 1.0 3 0.9 1 2 0.8 3 1 Curve 1: UR = 100 V Curve 2: UR = 200 V Curve 3: UR ≥ 250 V and ≤ 40 V 0.7 2, 3 1 ESR0 = typical at 20 °C and 100 Hz C0 = capacitance at 20 °C and 100 Hz 0.6 - 100 - 50 0 50 Tamb (°C) - 100 100 - 50 0 50 100 150 Tamb (°C) Fig. 6 - Typical multiplier of capacitance as a function of ambient temperature Fig. 8 - Typical multiplier of ESR as a function of ambient temperature 1.1 1.5 C C0 ESR ESR0 1.0 1.0 3 0.9 2 2 0.8 0.7 1 0.5 Curve 1: UR = 10 V and 16 V Curve 2: UR = 25 V, 35 V and 40 V Curve 3: UR ≥ 40 V 1 Curve 1: UR > 100 V Curve 2: UR ≤ 100 V C0 = capacitance at 20 °C and 100 Hz 0.6 1 10 102 ESR0 = typical at 20 °C and 100 Hz 103 f (Hz) Fig. 7 - Typical multiplier of capacitance as a function of frequency Revision: 09-Mar-12 104 0 1 10 102 103 f (Hz) 104 Fig. 9 - Typical multiplier of ESR as a function of frequency Document Number: 28340 7 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 056/057 PSM-SI www.vishay.com Vishay BCcomponents IMPEDANCE (Z) 105 ESR ESR0 10 1 1 Z (mΩ) Curve 1: UR ≥ 250 V Curve 2: UR = 200 V Curve 3: UR ≤ 100 V 2 3 4 104 2 6 7 8 9 10 11 103 1 102 2, 3 1 Z0 = typical impedance at 20 °C and 10 kHz - 50 0 100 150 101 1 10 105 102 103 104 105 106 f (Hz) 107 Fig. 13 - Typical impedance as a function of frequency Fig. 10 - Typical multiplier of impedance as a function of ambient temperature 105 Curve 1: 68 µF Curve 2: 150 µF Curve 3: 220 µF Curve 4: 330 µF Curve 5: 680 µF Curve 6: 1500 µF 1 104 Tamb = 20 °C Case Ø D x L = 22 mm x 25 mm 50 Tamb (°C) Z (mΩ) Curve 7: 1500 µF Curve 8: 2200 µF Curve 9: 3300 µF Curve 10: 4700 µF Curve 11: 6800 µF 5 3 - 100 Curve 1: 47 µF Curve 2: 100 µF Curve 3: 150 µF Curve 4: 220 µF Curve 5: 470 µF Curve 6: 1000 µF 1 2 3 4 Curve 7: 2200 µF Curve 8: 3300 µF Curve 9: 4700 µF Curve 10: 6800 µF Curve 11: 10 000 µF Curve 1: 100 µF Curve 2: 220 µF Curve 3: 330 µF Curve 4: 470 µF Curve 5: 1000 µF Curve 6: 2200 µF Z (mΩ) 1 104 2 3 4 Curve 7: 3300 µF Curve 8: 4700 µF Curve 9: 6800 µF Curve 10: 10 000 µF Curve 11: 15 000 µF 5 5 10 3 103 6 7 8 9 10 11 102 6 7 8 9 10 11 102 Tamb = 20 °C Tamb = 20 °C Case Ø D x L = 22 mm x 30 mm 101 1 10 102 103 104 105 106 f (Hz) Case Ø D x L = 25 mm x 30 mm and 22 mm x 40 mm 107 101 1 10 Fig. 11 - Typical impedance as a function of frequency 1 Curve 7: 4700 µF Curve 8: 6800 µF Curve 9: 10 000 µF Curve 10: 15 000 µF Curve 11: 22 000 µF 105 Curve 1: 220 µF Curve 2: 470 µF Curve 3: 680 µF Curve 4: 1000 µF Curve 5: 2200 µF Curve 6: 4700 µF Z (mΩ) 104 1 2 3 4 10 104 106 f (Hz) 107 105 Curve 1: 150 µF Curve 2: 330 µF Curve 3: 470 µF Curve 4: 680 µF Curve 5: 1500 µF Curve 6: 3300 µF Z (mΩ) 3 103 Fig. 14 - Typical impedance as a function of frequency 105 104 102 2 3 4 10 5 Curve 7: 6800 µF Curve 8: 10 000 µF Curve 9: 15 000 µF Curve 10: 22 000 µF Curve 11: 33 000 µF Case Ø D x L = 30 mm x 40 mm and 25 mm x 50 mm 3 5 102 6 7 8 9 10 11 6 7 8 9 10 11 102 Tamb = 20 °C Tamb = 20 °C Case Ø D x L = 30 mm x 30 mm and 25 mm x 40 mm 101 1 10 10 2 10 3 10 4 10 5 10 6 f (Hz) 10 Fig. 12 - Typical impedance as a function of frequency Revision: 09-Mar-12 7 101 1 10 10 2 10 3 10 4 10 5 106 f (Hz) 107 Fig. 15 - Typical impedance as a function of frequency Document Number: 28340 8 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 056/057 PSM-SI www.vishay.com Vishay BCcomponents IMPEDANCE (Z) 105 105 Curve 1: 330 µF Curve 2: 680 µF Curve 3: 1000 µF Curve 4: 1500 µF Curve 5: 3300 µF Curve 6: 6800 µF Z (mΩ) 104 Curve 7: 10 000 µF Curve 8: 15 000 µF Curve 9: 22 000 µF Curve 10: 33 000 µF Curve 11: 47 000 µF Curve 1: 470 µF Curve 2: 1000 µF Curve 3: 1500 µF Curve 4: 2200 µF Curve 5: 4700 µF Curve 6: 10 000 µF Z (mΩ) 104 Curve 7: 15 000 µF Curve 8: 22 000 µF Curve 9: 33 000 µF Curve 10: 47 000 µF Curve 11: 68 000 µF 1 1 2 3 4 103 Case Ø D x L = 35 mm x 40 mm and 30 mm x 50 mm Case Ø D x L = 35 mm x 50 mm 2 3 4 103 5 5 6 7 8 9 10 11 102 101 1 10 Tamb = 20 °C 102 6 7 8 9 10 11 102 103 104 105 106 f (Hz) Tamb = 20 °C 101 1 10 107 Fig. 16 - Typical impedance as a function of frequency 102 103 104 105 106 f (Hz) 107 Fig. 17 - Typical impedance as a function of frequency RIPPLE CURRENT AND USEFUL LIFE 2.4 2.3 IA IR 2.2 2.1 2.0 1.9 1.8 1.7 1 life multiplier 2 1. 1.6 5 1. 2 1.5 5 2. 3 1.4 4 5 1.3 8 10 1.2 15 Useful life at 85 °C and IR applied: 12 000 h (450 V types: 5000 h) 0.5 0.0 40 30 (1) 0.8 (1) 60 IR = rated ripple current at 100 Hz and 85 °C 1.0 45 IA = actual ripple current at 100 Hz and 85 °C 20 1.1 50 60 70 80 Tamb (°C) 90 Fig. 18 - Multiplier of useful life as a function of ambient temperature and ripple current load Revision: 09-Mar-12 Document Number: 28340 9 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 056/057 PSM-SI www.vishay.com Vishay BCcomponents Table 4 MULTIPLIER OF RIPPLE CURRENT (IR) AS A FUNCTION OF FREQUENCY IR MULTIPLIER FREQUENCY (Hz) UR = 10 V to 25 V UR = 40 V to 100 V UR > 100 V 50 0.93 0.91 0.86 100 1.00 1.00 1.00 200 1.04 1.05 1.13 400 1.07 1.09 1.21 1000 1.11 1.13 1.29 2000 1.13 1.15 1.32 4000 1.15 1.18 1.35 10 000 1.18 1.22 1.40 Table 5 TEST PROCEDURES AND REQUIREMENTS TEST NAME OF TEST Endurance REFERENCE IEC 60384-4/ EN130300 subclause 4.13 PROCEDURE (quick reference) REQUIREMENTS Tamb = 85 C; UR applied; 5000 h (450 V types: 2000 h) UR 100 V; C/C: ± 15 % UR > 100 V; C/C: ± 10 % ESR 1.3 x spec. limit Z 2 x spec. limit IL5 spec. limit UR 100 V; C/C: ± 45 % UR > 100 V; C/C: ± 30 % ESR 3 x spec. limit Z 3 x spec. limit IL5 spec. limit no short or open circuit, no visible damage total failure percentage: UR 100 V; 1 % UR 100 V; 3 % Useful life CECC 30301 subclause 1.8.1 Tamb = 85 C; UR and IR applied; 12 000 h (450 V types: 2000 h) Shelf life (storage at high temperature) IEC 60384-4/ EN130300 subclause 4.17 Tamb = 85 C; no voltage applied; 500 h C/C: ±10 % after test: UR to be applied for 30 min, 24 h to 48 h before measurement ESR 1.2 x spec. limit Revision: 09-Mar-12 IL5 2 x spec. limit Document Number: 28340 10 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 Legal Disclaimer Notice www.vishay.com Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. Material Category Policy Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (EEE) - recast, unless otherwise specified as non-compliant. Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU. Revision: 12-Mar-12 1 Document Number: 91000