Downloads for Wall Plug-Ins DC Power Supplies (WDU18-100)

Wall Plug - Ins
WDU18-100
Electrical Specifications (@25C)
1. Primary Rating: 120V 60Hz 6W
2. Primary Excitation Current: 40mA Max
3. Secondary Rating: 18VDC ± 5%, 100mADC
4. Secondary No-Load Rating: 28.2VDC Ref.
5. Output Ripple Voltage: 800mV Max
6. Operating Temperature Range: -10 Deg C to +40 Deg C
7. Temperature Rise: 75 Deg C Max at rated load
50 Deg C Max on enclosure surface
Mechanical Parameters:
Case Type: Thermoplastic molded enclosure.
Output Cord: 24 AWG, 6 Ft. Long Min.
Agency File:
UL/CUL: File E104603, UL 1310
CSA: LR67888
A. Dimensions:
H
W
D
56
43
37
*Units: In Millimeter
120V
60HZ
470uF/35V
B. Schematic:
Technical Note: 1. Inside (tip)-positive (+), outside-negative (-)
U.S. DOE Compliance per Sec. 301 of EISA 2007: As of July 1, 2008, this
product is intended for use as follows:
1. Requires Federal Food and Drug Administration listing and approval
as a medical device in accordance with section 513 of the Federal
Food, Drug, and Cosmetic Act (21 U.S.C. 360c)
2. Powers the charger of a detachable battery pack or charges the
battery of a product that is fully or primarily motor operated.
3. As a service part or a spare part for an end-use product manufactured
before July 1, 2008, that constitutes the primary load of this power
supply.
NAMEPLATE
MARKING
AC ADAPTOR
MODEL: WDU18-100
INPUT: 120V 60Hz 6W
OUTPUT: 18.0VDC 100mA
CLASS 2 TRANSFORMER
LISTED
UL
R
R
AEC-T3518B
16UO
E104603
LR67888
MADE IN CHINA
RoHS Compliance: As of manufacturing date February 2005, all standard
products meet the requirements of 2011/65/EU, known as the RoHS initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact
Triad Magnetics’ website for the most current version.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
Publish Date: December 4, 2013