DC-DC Converter UNIT PU-S SERIES (1 W UNREGULATED) FEATURES •Single in line package •100% Burned in •High Efficiency •Continous short circuit protection •Internal SMD Technology •No heatsink required •UL 94V-0 Package material •RoHS compliant •3 Years warranty OUTPUT SPECIFICATIONS Voltage Set point Accuracy INPUT SPECIFICATIONS +/-2% max Temperature Coefficient Input Voltage Range Input Filter +/-0.05%/ °C Protection 100mVp-p max +/-0.1.2% max +/-8% max 20% of Full Load Ripple & Noise (20MHz BW) Line Regulation1 Load Regulation2 Minimum Load Efficiency Isolation Voltage3 Isolation Resistance Automatic Short circuit Restart Isolation Capacitance Switching Frequency ENVIRONMENTAL SPECIFICATIONS Operating Temperature 74%-83% 3000 Vdc min 109 ohms min 20pF max 100 KHz min MTBF4 >2.000,000 Hours Weight 2.1g Typ Case Material Non-Conductive Plastic Case Size Conducted Emissions 19.6mm*7.5mm*10.2mm EN55022 Class A Radiated Emissions EN55022 Class A -40 °C to +85 °C Storage Temperature Humidity Cooling Fuse Recommended GENERAL SPECIFICATIONS Continuous Short Circuit Protection +/-10% max Capacitor Typ -55 °C to +125 °C 95% max Free-Air Convection ALL SPECIFICATIONS TYPICAL AT NOMINAL LINE, FULL LOAD , AND 25 °C UNLESS OTHERWISE NOTED. [1] Line Regulation is for a 1.0% change in input Voltage. [2] Load Regulation is for output load current change from 20% to 100%. [3] 1500Vdc for 10 seconds. 3000Vdc for 3 seconds. [4] MIL-HDBK-217F @25 °C , Ground Benign Power Systems – The Power Solution Web: Email: www.Power-Systems.de [email protected] All specifications are subject to change without notice. Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Page (1) Version 1.0, 07th July 2010 DC-DC Converter UNIT PU-S SERIES (1 W UNREGULATED) ●SELECTION GUIDE(1) 1W 1000VDC ISOLATION MODEL NUMBER INPUT VOLTAGE (VDC) OUTPUT VOLTAGE (VDC) OUTPUT CURRENT (mA) INPUT[5] CURRENT(mA) FULL LOAD NO LOAD EFF (%)[6] ISOLATION (VDC) PACKAGE PUS-0505G1S 5 5 200 256 34 78 3000 G PUS-0509G1S 5 9 111 253 33 79 3000 G PUS-0512G1S 5 12 84 253 33 79 3000 G PUS-0515G1S 5 15 67 251 33 80 3000 G PUD0505G1S 5 +/-5 +/-100 256 34 78 3000 G PUD0512G1S 5 +/-12 +/-42 253 33 79 3000 G PUD0505G1S 5 +/-15 +/-34 251 33 80 3000 G PUS-1205G1S 12 5 200 108 14 77 3000 G PUS-1209G1S 12 9 111 105 13 79 3000 G PUS-1212G1S 12 12 84 105 13 80 3000 G PUS-1215G1S 12 15 67 103 13 81 3000 G PUD-1205G1S 12 +/-5 +/-100 106 14 78 3000 G PUD-1212G1S 12 +/-12 +/-42 105 13 80 3000 G PUD-1215G1S 12 +/-15 +/-34 103 13 81 3000 G PUS-2405G1S 24 5 200 54 8 77 3000 G PUS-2409G1S 24 9 111 53 7 78 3000 G PUS-2412G1S 24 12 84 53 7 79 3000 G PUS-2415G1S 24 15 67 52 7 80 3000 G PUD-2405G1S 24 +/-5 +/-100 53 8 78 3000 G PUD-2412G1S 24 +/-12 +/-42 53 7 79 3000 G PUD-2415G1S 24 +/-15 +/-34 53 7 80 3000 G Note: Other input to output voltages may be available. Please contact factory. [5] NOMINAL INPUT VOLTAGE. [6] NOMINAL INPUT VOLTAGE, FULL LOAD. [6] NOMINAL INPUT VOLTAGE. [7] NOMINAL INPUT VOLTAGE, FULL LOAD. Power Systems – The Power Solution Web: Email: www.Power-Systems.de [email protected] All specifications are subject to change without notice. Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Page (2) Version 1.0, 07th July 2010 DC-DC Converter UNIT PU-S SERIES (1 W UNREGULATED) ●MECHANICAL DIMENSIONS & RECOMMENDED FOOTPRINT DETAILS PACKAGE „G“ PIN SINGLE DUAL 1 +Vin +Vin 2 -Vin -Vin 4 -Vout -Vout 5 NP COMMON 6 +Vout +Vout ●SIMPLIFIED SCHEMATIC ●TYPICAL APPLICATIONS Power Systems – The Power Solution Web: Email: www.Power-Systems.de [email protected] All specifications are subject to change without notice. Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Page (3) Version 1.0, 07th July 2010 DC-DC Converter UNIT PU-S SERIES (1 W UNREGULATED) ●TYPICAL PERFORMANCE CURVES Power Systems – The Power Solution Web: Email: www.Power-Systems.de [email protected] All specifications are subject to change without notice. Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Page (4) Version 1.0, 07th July 2010 DC-DC Converter UNIT PU-S SERIES (1 W UNREGULATED) ●INPUT FUSE SELECTION GUIDE Note: Other input to output voltages may be available. Please contact factory. PU-S SERIES APPLICATION NOTES: EXTERNAL CAPACITANCE REQUIREMENTS: Output filtering is required for operation. A minimum of 10uF is needed. Output capacitance may be increased for additional filtering, not to exceed 220uF. To meet the reflected ripple requirements of the converter, an input impedance of less than 0.5 ohm from DC to 250 KHz is required. We can offer EMC-filter according to EN55011/22 Class B Negative Outputs: A negative output voltage may be obtained by connecting the +OUT to circuit ground and connecting –OUT as the negative output. [10] NOMINAL INPUT VOLTAGE. [11] NOMINAL INPUT VOLTAGE, FULL LOAD. Power Systems – The Power Solution Web: Email: www.Power-Systems.de [email protected] All specifications are subject to change without notice. Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Page (5) Version 1.0, 07th July 2010