DC-AC INVERTER UNIT

DC-AC INVERTER UNIT
PS-DA0401-01(S) (20 W QUAD OUTPUTS)
(PRELIMINARY INFORMATION)
DESCRIPTION :
This low profile DC to AC Inverter is developed for quad lamps.
APPLICABLE LCD:
15 to 17 inches quad lamp type
Lamp Voltage 800 Vrms
Lamp Current 4 x 6.0 mArms
Lamp Start Up Voltage 1.500 Vrms (Vin : 12 Vdc)
FEATURES :
Remote ON/OFF
Independent Open Lamp Detection for each side
Current balance circuit
RoHS compliant (S)
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
DIMENSIONS :
-20°C ~ +60°C
-20°C ~ +85°C
95 %RH max
180 x 30 x 16 mm
Pin 1
Pin 1
Unit : mm
Weight :40 (g) typ.
Pin 1
Pin 1
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
Part Description
PCB
Connector CN1
Qty.
1
1
Material
UL94V-0 (FR-4 or CEM-3)
S7B-PH-K
Note
t=1m m
JST or equal
3
Connector CN2 ~ CN3
2
SM04(4.0)B-BHS-1-TB
JST or equal
Output side CN2
Input side CN1:
Pin No.
Symbols
Ratings
Vin
10.8 ~ 13.2 Vdc
CN 1-1+2
GND
CN 1-3+4+6
Vrm t
0 ~ 0.4 = OFF / 4.5 ~ Vin = ON
CN 1-5
Vbr
0 ~ 5.0 Vdc
CN 1-7
Pin No.
CN 2-1
CN 2-2
CN 2-3
Symbols
Vhigh1
Vhigh2
N.C
Ratings
800 Vrm s (6.0 m Arm s )
800 Vrm s (6.0 m Arm s )
CN 2-4
Vlow
(GND)
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 1.1.6, 07th December 2010
DC-AC INVERTER UNIT
PS-DA0401-01(S) (20 W QUAD OUTPUTS)
(PRELIMINARY INFORMATION)
ELECTRICAL CHARACTERISTICS :
Conditions
Parameters
Symbols
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
No load Shutdown
Iout
Iout
Iin
F
Vopen
Tsd
Note 1 :
Specification
Vin (V)
Vbr (V)
Tu (°C)
Min.
Typ.
Max.
12±1.2
12±0.6
12±1.2
12±1.2
11.4
12±1.2
0.0
5.0
0.0
0.0
0.0
0.0
-20 ~ +60
-20 ~ +60
-20 ~ +60
-20 ~ +60
-20 ~ +60
-20 ~ +60
5.5
1.7
45
1.300
1.0
6.0
2.0
1.77
52
1.500
-
6.5
2.3
2.2
60
-
Unit
Note
mArms
mArms
Adc
kHz
Vrms
sec
Duty 100%
without load
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
TEST CIRCUIT :
F
Vin
12 V
V
SW4
SW 1
Operation of unit
a
Operation
b
Non operation
CN2-2
CN1-4
RL2
b
T1
A
~
CN2-4
SW1
RL1
CL1
CL2
a
V
V
~
CN2-1
CN1-1
CN1-2
CN1-3
Vrmt
0 / 5 Vdc
Vopen
SW3
Iin
A
1000:1
PROBE
F
CN1-5
Iout
2
A
~
Iout
1
SW5
SW3
CN3-1
SW4
CN1-6
CN3-2
RL2
RL1
CL1
CL2
CN1-7
Vbr
0 ~ 5.0 Vdc
A
~
CN3-4
Iout
2
A
~
Iout
1
SW5
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)
Version 1.1.6, 07th December 2010