ADT7490 D

ADT7490
Remote Thermal Monitor
and Fan Controller with
PECI Interface
The ADT7490 is a thermal monitor and multiple PWM fan
controller for noise-sensitive or power-sensitive applications requiring
active system cooling. The ADT7490 includes a local temperature
sensor, two remote temperature sensors including series resistance
cancellation, and monitors CPU temperature with a PECI interface.
The ADT7490 can drive a fan using either a low or high frequency
drive signal, and measure and control the speed of up to four fans so
they operate at the lowest possible speed for minimum acoustic noise.
The automatic fan speed control loop optimizes fan speed
for a given temperature using the PECI, remote, or local temperature
information. The effectiveness of the system’s thermal solution can be
monitored using the THERM input. The ADT7490 also provides
critical thermal protection to the system using the bidirectional
THERM/SMBALERT pin as an output to prevent system or
component overheating.
Features
• Temperature Measurement
1 Local On-Chip Temperature Sensor
♦ 2 Remote Temperature Sensors
♦ 3 Current External Temperature Sensors with Series Resistance
Cancellation (SRC)
♦ PECI Interface for CPU Thermal Information and Support of Up
to 4 PECI Inputs on 1 Pin
Fan Drive and Fan Speed Control
♦ 3 High Frequency or Low Frequency PWM Outputs for Use with
3-wire or 4-wire Fans
♦ 4 TACH Inputs to Measure Fan Speed
♦ OS Independent Automatic Fan Speed Control Based on Thermal
Information
♦ Dynamic TMIN Control Mode to Optimize System Acoustics
♦ Default Startup at 100% PWM for All Fans for Robust Operation
Bidirectional THERM/SMBALERT Pin to Flag Out-of-Limit and
Overtemperature Conditions
GPIO Functionality to Support Extra Features
♦ Can be Used for Loadline Setting for Voltage Regulation, LED
Control, or Other Functions
IMON Monitoring for CPU Current and Power Information
Footprint and Register Compatible with ADT7473/ADT7475/
ADT7476/ADT7476A Family of Fan Controllers
SMBus Interface with Addressing Capability for Up to 3 Devices
♦
•
•
•
•
•
•
Applications
www.onsemi.com
QSOP−24 NB
CASE 492B
PIN ASSIGNMENT
SDA
1
24 PWM1/XTO
SCL
2
23 VCCP
GND
3
22 +2.5VIN/THERM
VCC
4
21 +12VIN
GPIO1
5
20 +5VIN
GPIO2
6
PECI
7
VTT
8
17 D1−
TACH3 9
PWM2/
10
SMBALERT
TACH1 11
16 D2+
ADT7490
19 IMON
18 D1+
15 D2−
14 *
TACH2 12
13 PWM3/ADDREN
*TACH4/THERM/SMBALERT/ADDR SELECT
MARKING DIAGRAMS
1
ADT7490
ARQZ
#DateCode
Assembly Lot
TOP MARKING
BOTTOM MARKING
# = Pb-Free Package
ORDERING INFORMATION
See detailed ordering and shipping information on page 74 of
this data sheet.
• Personal Computers
• Servers
© Semiconductor Components Industries, LLC, 2016
January, 2016 − Rev. 6
1
Publication Order Number:
ADT7490/D
ADT7490
ADDR SELECT
SCL
SDA
ADT7490
SMBus
ADDRESS
SELECTION
GPIO1
GPIO
REGISTER
GPIO2
ADDRESS
POINTER
REGISTER
PERFORMANCE
MONITORING
THERM/
SMBALERT
PWM
CONFIGURATION
REGISTERS
THERMAL
PROTECTION
TACH1
TACH2
INTERRUPT
MASKING
FAN SPEED
COUNTER
TACH3
TACH4
PWM1
PWM2
PWM3
PWM REGISTERS
AND CONTROLLERS
(HF AND LF)
ACOUSTIC
ENHANCEMENT
PECI
INTERFACE
PECI
AUTOMATIC
FAN SPEED
CONTROL
DYNAMIC TMIN
CONTROL
ACOUSTIC
ENHANCEMENT
CONTROL
VTT
VCC
VCCP
+12VIN
+5VIN
10-BIT
ADC
INPUT
SIGNAL
CONDITIONING
AND
ANALOG
MULTIPLEXER
+2.5VIN
IMON
D1+
D1−
D2+
SERIAL BUS
INTERFACE
BAND GAP
REFERENCE
D2−
BAND GAP
TEMP. SENSOR
GND
Figure 1. Functional Block Diagram
www.onsemi.com
2
INTERRUPT
STATUS
REGISTERS
LIMIT
COMPARATORS
VALUE AND
LIMIT
REGISTERS
ADT7490
Table 1. ABSOLUTE MAXIMUM RATINGS
Parameter
Rating
Unit
Positive Supply Voltage (VCC)
3.6
V
Maximum Voltage on +12 VIN Pin
16
V
Maximum Voltage on +5 VIN Pin
6.25
V
Maximum Voltage on All Open-drain Outputs (excluding PWM pins)
3.6
V
Maximum Voltage on TACHx/PWMx Pins
+5.5
V
Voltage on Remaining Input or Output Pins
−0.3 to +4.2
V
Input Current at Any Pin
±5
mA
Package Input Current
±20
mA
Maximum Junction Temperature (TJ MAX)
150
°C
−65 to +150
°C
Storage Temperature Range
Lead Temperature, Soldering
IR Reflow Peak Temperature
Pb-Free Peak Temperature
Lead Temperature (Soldering, 10 sec)
220
260
300
ESD Rating
HBM
FICDM
2
0.5
°C
kV
Stresses exceeding those listed in the Maximum Ratings table may damage the device. If any of these limits are exceeded, device functionality
should not be assumed, damage may occur and reliability may be affected.
NOTE: This device is ESD sensitive. Use standard ESD precautions when handling.
Table 2. THERMAL CHARACTERISTICS (Note 1)
Package Type
24-lead QSOP
qJA
qJC
Unit
122
31.25
°C/W
1. qJA is specified for the worst-case conditions, that is, a device soldered in a circuit board for surface-mount packages.
Table 3. ELECTRICAL CHARACTERISTICS
(TA = TMIN to TMAX, VCC = VMIN to VMAX, unless otherwise noted) (Note 1)
Parameter
Conditions
Min
Typ
Max
Unit
3.0
3.3
3.6
V
Interface Inactive, ADC Active
−
1.5
5.0
mA
0°C ≤ TA ≤ 85°C
−40°C ≤ TA ≤ +125°C
−
−
−
±0.5
−
0.25
±1.5
±2.5
−
°C
Remote Diode Sensor Accuracy
0°C ≤ TA ≤ 85°C
−40°C ≤ TA ≤ +125°C
−
−
−
±0.5
−
0.25
±1.5
±2.5
−
°C
Remote Sensor Source Current
Mid Level
Low Level
High Level
−
−
−
12
72
192
−
−
−
mA
Series Resistance Cancellation
(Note 2)
The ADT7490 Cancels Up to 2 kW in
Series with the Remote Thermal Sensor
−
−
1.5
kW
Power Supply
Supply Voltage
Supply Current, ICC
Temperature-to-Digital Converter
Local Sensor Accuracy
Resolution
www.onsemi.com
3
ADT7490
Table 3. ELECTRICAL CHARACTERISTICS (continued)
(TA = TMIN to TMAX, VCC = VMIN to VMAX, unless otherwise noted) (Note 1)
Parameter
Conditions
Min
Typ
Max
Unit
−
−
±2
±1.5
%
Analog-to-Digital Converter (Including MUX and Attentuators)
Total Unadjusted Error (TUE)
For All Channels: −40°C ≤ TA ≤ +125°C
For All Other Channels Except +12 VIN:
0°C ≤ TA ≤ +125°C
−
−
Differential Non-linearity (DNL)
8 Bits
−
−
±1
LSB
−
±0.1
−
%/V
Power Supply Sensitivity
Conversion Times (Note 2)
Voltage Inputs
VTT Voltage Input (Note 3)
Local Temperature
Remote Temperature
Total Monitoring Cycle Time
Input Resistance
Averaging Enabled, All Channels
Excluding VTT (Note 3)
Averaging Enabled
Averaging Enabled
Averaging Enabled
Averaging Enabled
−
−
−
−
11
12
12
38
13
14
14
43
Averaging disabled
−
−
169
19
193
−
ms
150
70
200
100
−
−
kW
−
−
−
−
±10
±14
%
−
−
65,535
−
−
−
−
109
329
5,000
10,000
−
−
−
−
RPM
For +12 VIN Channel
For All Other Channels
ms
Fan RPM-to-Digital Converter
Accuracy
0°C ≤ TA ≤ 85°C
−40°C ≤ TA ≤ +125°C
Full-scale Count
Nominal Input RPM
Fan Count = 0xBFFF
Fan Count = 0x3FFF
Fan Count = 0x0438
Fan Count = 0x021C
Open-Drain Digital Outputs, PWM1 TO PWM3, XTO
−
−
8.0
mA
Output Low Voltage, VOL
IOUT = −8.0 mA
−
−
0.4
V
High Level Output Current, IOH
VOUT = VCC
−
0.1
20
mA
Current Sink, IOL
Open-Drain Serial Data Bus Output (SDA)
Output Low Voltage, VOL
IOUT = −4.0 mA
−
−
0.4
V
High Level Output Current, IOH
VOUT = VCC
−
0.1
1.0
mA
Input High Voltage, VIH
2.0
−
−
V
Input Low Voltage, VIL
−
−
0.8
V
Hysteresis
−
500
−
mV
SMBus Digital Inputs (SCL, SDA)
Digital I/O (PECI Pin) (Note 2)
0.95
−
1.26
V
Input High Voltage, VIH
VTT, Supply Voltage
0.55 × VTT
(Note 3)
−
−
V
Input Low Voltage, VIL
−
−
0.5 × VTT
(Note 3)
V
0.1 × VTT
(Note 3)
−
−
mV
−
−
6.0
mA
Hysteresis (Note 2)
Hysteresis between Input Switching
Levels
High Level Output Source Current,
ISOURCE
VOH = 0.75 × VTT
Low Level Output Sink Current, ISINK
VOL = 0.25 × VTT
0.5
−
1.0
mA
Signal Noise Immunity, VNOISE
Noise Glitches from 10 MHz to
100 MHz, Width Up to 50 ns
300
−
−
mV
p-p
www.onsemi.com
4
ADT7490
Table 3. ELECTRICAL CHARACTERISTICS (continued)
(TA = TMIN to TMAX, VCC = VMIN to VMAX, unless otherwise noted) (Note 1)
Parameter
Conditions
Min
Typ
Max
Unit
Maximum Input Voltage
2.0
−
−
−
−
5.5
V
Minimum Input Voltage
−
−0.3
−
−
0.8
−
V
−
0.5
−
V p-p
Input High Voltage, VIH
0.75 × VCCP
−
−
V
Input Low Voltage, VIL
−
−
0.4
V
±1
−
mA
Digital Input Logic Levels (TACH1 to TACH3)
Input High Voltage, VIH
Input Low Voltage, VIL
Hysteresis
Digital Input Logic Levels (THERM)
Digital Input Current
Input High Current, IIH
VIN = VCC
−
Input Low Current, IIL
VIN = 0
−
±1
−
mA
−
5.0
−
pF
10
−
400
kHz
Glitch Immunity, tSW
−
−
50
ns
Bus Free Time, tBUF
4.7
−
−
ms
SCL Low Time, tLOW
4.7
−
−
ms
SCL High Time, tHIGH
4.0
−
50
ms
SCL, SDA Rise Time, tr
−
−
1,000
ns
SCL, SDA Fall Time, tf
−
−
300
ms
250
−
−
ns
15
−
35
ms
Input Capacitance, CIN
Serial Bus Timing (Note 2) (See Figure 2)
Clock Frequency, fSCLK
Data Setup Time, tSU;DAT
Detect Clock Low Timeout, tTIMEOUT
Can be Optionally Disabled
1. All voltages are measured with respect to GND, unless otherwise specified. Typical voltages are TA = 25°C and represent a parametric norm.
Logic inputs accept input high voltages up to VMAX, even when the device is operating down to VMIN. Timing specifications are tested at logic
levels of VIL = 0.8 V for a falling edge, and VIH = 2.0 V for a rising edge.
2. Guaranteed by design, not production tested.
3. VTT is the voltage input on Pin 8. The VTT voltage is determined by the processor installed on the system.
t LOW
tF
t HD; STA
tR
SCL
t HD; STA
t HD; DAT
t HIGH
t SU; STA
t SU; DAT
t SU; STO
SDA
P
t BUF
S
S
Figure 2. Serial Bus Timing Diagram
www.onsemi.com
5
P
ADT7490
Table 4. PIN ASSIGNMENT
Pin No.
Mnemonic
Type
1
SDA
Digital I/O
Description
2
SCL
Digital Input
3
GND
Ground
Ground Pin.
3.3 V ±10%.
SMBus Bidirectional Serial Data. Open drain, requires SMBus pullup.
SMBus Serial Clock Input. Open drain, requires SMBus pullup.
4
VCC
Power Supply
5
GPIO1
Digital Input/Output
General-purpose Open-drain Digital Input/Output. Frequently used for
switching load line resistors into VR load line circuitry or for switching LEDs
using external FETs.
6
GPIO2
Digital Input/Output
General-purpose Open-drain Digital Input/Output. Frequently used for
switching load line resistors into VR load line circuitry or for switching LEDs
using external FETs.
7
PECI
Digital Input/Output
PECI Input to Report CPU Thermal Information. PECI voltage level is
referenced on the VTT input.
8
VTT
Analog Input
Voltage Reference for PECI. This is the supply voltage for the PECI interface
and must be present to measure temperature over the PECI interface. This
voltage is also monitored and presented in Register 0x1E.
9
TACH3
Digital Input
Fan Tachometer Input to Measure Speed of Fan 3 (Open-drain Digital Input).
10
PWM2/SMBALERT
Digital Output
Pulse-width Modulated Output to Control Fan 2 Speed. Open drain requires
10 kW typical pullup. Digital Output (Open Drain). This pin can be
reconfigured as an SMBALERT interrupt output to signal out-of-limit
conditions.
11
TACH1
Digital Input
Fan Tachometer Input to Measure Speed Of Fan 1 (Open-drain Digital Input).
12
TACH2
Digital Input
Fan Tachometer Input To Measure Speed Of Fan 2 (Open-drain Digital Input).
13
PWM3/
ADDREN
Digital Output
Pulse-width Modulated Output to Control Fan 3 Speed. Open drain requires
10 kW typical pullup. If pulled low on powerup, the ADT7490 enters address
select mode, and the state of Pin 14 (ADDR SELECT) determines the
ADT7490 slave address.
14
TACH4/THERM/
SMBALERT/
ADDR SELECT
Digital Input/Output
15
D2−
Analog Input
Negative Connection for Remote Temperature Sensor 2.
16
D2+
Analog Input
Positive Connection to Remote Temperature Sensor 2.
17
D1−
Analog Input
Negative Connection for Remote Temperature Sensor 1.
18
D1+
Analog Input
Positive Connection to Remote Temperature Sensor 1.
19
IMON
Analog Input
Monitors Current Output of Analog Devices ADP319x family of VRD10/VRD11
controllers.
Fan Tachometer Input to Measure Speed of Fan 4 (Open-drain Digital Input).
May be reconfigured as a bidirectional THERM pin. Can be connected to the
PROCHOT output of the processor, to time and monitor PROCHOT assertions.
Can be used as an output to signal overtemperature conditions or for clock
modulation purposes. Active Low Digital Output. The SMBALERT pin is used to
signal out-of-limit comparisons of temperature, voltage, and fan speed. This is
compatible with SMBus alert. Can also be used at device powerup to assign
SMBus address.
20
+5 VIN
Analog Input
Monitors 5.0 V Supply Using Internal Resistor Dividers.
21
+12 VIN
Analog Input
Monitors 12 V Supply Using Internal Resistor Dividers.
22
+2.5 VIN/THERM
Analog Input
Monitors 2.5 V Supply Using Internal Resistor Dividers. Alternatively, this pin
can be reconfigured as a bidirectional THERM pin. Can be connected to the
PROCHOT output of the processor to time and monitor PROCHOT assertions.
Can be used as an output to signal overtemperature conditions or for clock
modulation purposes.
23
VCCP
Analog Input
Monitors CPU VCC Voltage (to maximum of 3.0 V). All voltage inputs can
have their resistor dividers removed allowing for full-scale input of 2.25 V of
the ADC channel.
24
PWM1/XTO
Digital Output
Pulse-width Modulated Output to Control Fan 1 Speed. Open drain requires
10 kW typical pullup. Also functions as the output for the XNOR tree test
enable mode.
www.onsemi.com
6
ADT7490
Table 5. COMPARISON OF ADT7490 AND ADT7476A CONFIGURATIONS
Pin No.
ADT7490
ADT7476A
1
SDA
SDA
2
SCL
SCL
3
GND
GND
4
VCC
VCC
5
GPIO1
VID0/GPIO0
6
GPIO2
VID1/GPIO1
7
PECI
VID2/GPIO2
8
VTT
VID3/GPIO3
9
TACH3
TACH3
10
PWM2/SMBALERT
PWM2/SMBALERT
11
TACH1
TACH1
12
TACH2
TACH2
13
PWM3/ADDREN
PWM3/ADDREN
14
TACH4/THERM/SMBALERT/ADDR SELECT
TACH4/THERM/SMBALERT/GPIO6/ADDR SELECT
15
D2−
D2−
16
D2+
D2+
17
D1−
D1−
18
D1+
D1+
19
IMON
VID4/GPIO4
20
+5 VIN
+5 VIN
21
+12 VIN
+12 VIN/VID5
22
+2.5 VIN/ THERM
+2.5 VIN/ THERM
23
VCCP
VCCP
24
PWM1/XTO
PWM1/XTO
4.7
4.24
4.5
4.22
4.3
NORMAL IDD (mA)
NORMAL IDD (mA)
TYPICAL PERFORMANCE CHARACTERISTICS
DEV 1
DEV 3
4.1
DEV 2
3.9
3.7
3.5
3.0
DEV 2
4.20
4.18
DEV 1
4.16
DEV 3
4.14
3.1
3.2
3.3
3.4
3.5
4.12
−40
3.6
VDD (V)
−20
0
20
40
60
80
100
TEMPERATURE (°C)
Figure 3. Supply Current vs. Supply Voltage
Figure 4. Supply Current vs. Temperature
www.onsemi.com
7
120
ADT7490
TYPICAL PERFORMANCE CHARACTERISTICS (Cont’d)
2.0
1.5
1.0
0.5
0
−0.5
−1.0
−20
0
25
40
60
70
85
100
2.0
1.5
1.0
0.5
0
−0.5
−1.0
−1.5
−2.0
−40
125
−20
0
25
70
85
100
125
Figure 5. Local Temperature Sensor Error
Figure 6. Remote 1 Temperature Sensor Error
140
DEV 1
DEV 2
DEV 3
DEV 4
DEV 5
DEV 6
DEV 7
DEV 8
DEV 9
DEV 10
DEV 11
DEV 12
DEV 13
DEV 14
DEV 15
DEV 16
DEV 17
DEV 18
DEV 19
DEV 20
DEV 21
DEV 22
DEV 23
DEV 24
DEV 25
DEV 26
DEV 27
DEV 28
DEV 29
DEV 30
DEV 31
DEV 32
MEAN
LOW SPEC
HIGH SPEC
2.0
1.5
1.0
0.5
0
−0.5
−1.0
−1.5
−2.0
−40
−20
0
25
40
60
70
85
100
120
EXTERNAL 1
100
LOCAL
80
60
40
20
0
125
EXTERNAL 2
0
10
20
TEMPERATURE (°C)
30
40
4.0
TEMPERATURE ERROR (°C)
6
DEV 1
2
0
DEV 3
−2
−4
DEV 2
−6
200
400
600
800 1000 1200 1400 1600
100 mV
250 mV
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0
−0.5
−1.0
0
60
Figure 8. ADT7490 Response to Thermal Shock
8
4
50
TIME (s)
Figure 7. Remote 2 Temperature Sensor Error
TEMPERATURE ERROR (°C)
60
TEMPERATURE (°C)
2.5
−8
40
TEMPERATURE (°C)
3.0
TEMPERATURE ERROR (°C)
DEV 1
DEV 2
DEV 3
DEV 4
DEV 5
DEV 6
DEV 7
DEV 8
DEV 9
DEV 10
DEV 11
DEV 12
DEV 13
DEV 14
DEV 15
DEV 16
DEV 17
DEV 18
DEV 19
DEV 20
DEV 21
DEV 22
DEV 23
DEV 24
DEV 25
DEV 26
DEV 27
DEV 28
DEV 29
DEV 30
DEV 31
DEV 32
MEAN
LOW SPEC
HIGH SPEC
2.5
TEMPERATURE ERROR (°C)
2.5
−1.5
−40
3.0
DEV 1
DEV 2
DEV 3
DEV 4
DEV 5
DEV 6
DEV 7
DEV 8
DEV 9
DEV 10
DEV 11
DEV 12
DEV 13
DEV 14
DEV 15
DEV 16
DEV 17
DEV 18
DEV 19
DEV 20
DEV 21
DEV 22
DEV 23
DEV 24
DEV 25
DEV 26
DEV 27
DEV 28
DEV 29
DEV 30
DEV 31
DEV 32
MEAN
LOW SPEC
HIGH SPEC
MEASURED TEMPERATURE (°C)
TEMPERATURE ERROR (°C)
3.0
0
100
200
300
400
500
600
POWER SUPPLY NOISE FREQUENCY (MHz)
SERIES RESISTANCE (W)
Figure 9. Temperature Error vs. Series Resistance
Figure 10. Local Temperature Error vs. Power
Supply Noise Frequency
www.onsemi.com
8
ADT7490
TYPICAL PERFORMANCE CHARACTERISTICS (Cont’d)
20
100 mV
250 mV
0.4
TEMPERATURE ERROR (°C)
TEMPERATURE ERROR (°C)
0.6
0.2
0
−0.2
−0.4
−0.6
−0.8
−1.0
−1.2
0
100
200
300
400
500
15
10
5
40 mV
0
−5
−10
600
100 mV
60 mV
160
5
140
0
120
100
80
100 mV
60 mV
20
0
−20
40 mV
0
100
200
300
400
500
500
600
DEV 3
DEV 2
−10
DEV 1
−15
−20
−25
−30
−35
600
0
2
4
6
8
10 12 14 16 18 20 22
CAPACITANCE (nF)
Figure 13. Temperature Error vs. Differential Mode
Noise Frequency
Figure 14. Temperature Error vs. Capacitance
Between D+ and D−
1.5
8
1.0
DEV 1
DEV 2
DEV 3
0.5
DEV 3
6
4
ACCURACY (%)
ACCURACY (%)
400
−5
DIFFERENTIAL MODE NOISE FREQUENCY (MHz)
0
−0.5
−1.0
2
0
DEV 1
DEV 2
−2
−4
−1.5
−2.0
3.0
300
Figure 12. Temperature Error vs. Common-Mode
Noise Frequency
TEMPERATURE ERROR (°C)
TEMPERATURE ERROR (°C)
Figure 11. Remote Temperature Error vs. Power
Supply Noise Frequency
40
200
COMMON-MODE NOISE FREQUENCY (MHz)
POWER SUPPLY NOISE FREQUENCY (MHz)
60
100
0
−6
3.1
3.2
3.3
3.4
3.5
−8
−40
3.6
−20
0
20
40
60
80
100
TEMPERATURE (°C)
VDD (V)
Figure 15. TACH Accuracy vs. Supply Voltage
Figure 16. TACH Accuracy vs. Temperature
www.onsemi.com
9
120
ADT7490
Theory of Operation
The ADT7490 is a complete thermal monitor and multiple
fan controller for any system requiring thermal monitoring
and cooling. The device communicates with the system via
a serial system management bus. The serial bus controller
has a serial data line for reading and writing addresses and
data (Pin 1), and an input line for the serial clock (Pin 2). All
control and programming functions for the ADT7490 are
performed over the serial bus. In addition, Pin 14 can be
reconfigured as an SMBALERT output to signal
out-of-limit conditions.
Temperature Data REPLACE Mode
Feature Comparisons Between the ADT7490 and
ADT7476A
The CPU thermal information from PECI can be used in the
existing automatic fan control algorithms. This temperature
reading remains relative to TCC activation temperature and
the associated AFC control parameters are programmed in
relative temperatures as opposed to absolute temperatures,
and are in the same format as detailed in Table 6. PECIMIN,
TRANGE, and TCONTROL are user defined.
The REPLACE mode is configured by setting Bit 4 of
Register 0x36. In this mode, the data in the existing
Remote 1 registers are replaced by PECI0 data and vice
versa. This is a legacy mode that allows the thermal data
from CPU1 to be stored in the same registers as in the
ADT7476A. This reduces the software changes in systems
transitioning from CPUs with thermal diodes to CPUs with
a PECI interface. See the PECI Temperature Measurement
section for more details.
Fan Control Using PECI Information
The ADT7490 is pin and register map compatible with the
ADT7476A. The new or additional features are detailed in
the following sections.
PECI Input
CPU thermal information is provided through the PECI
input. The ADT7490 has PECI master capabilities and can
read the CPU thermal information through the PECI
interface. Each CPU address can have up to two PECI
domains. The ADT7490 has the ability to record four PECI
temperature readings corresponding to the four PECI
addresses of 0x30 to 0x33. The hotter of the two domains at
any given address is stored in the PECI value registers. A
PECI reading is a negative value, in degrees Celsius, which
represents the offset from the thermal control circuit (TCC)
activation temperature. PECI information is not converted
to absolute temperature reading. PECI information is in a
16-bit twos complement value; however, the ADT7490
records the sign bit as well as the bits from 12:6 in the 16-bit
PECI payload. See the Platform Environment Control
Interface (PECI) Specification from Intel® for more details
on the PECI data format. The PECI format is represented in
Table 6.
PWM = 100%
PWMMAX
TRANGE
PWM = 0%
PECIMIN
(TMIN)
x
Sign Bit
TCC
The automatic fan speed control incorporates a feature
called dynamic TMIN control. This intelligent fan control
feature reduces the design effort required to program the
automatic fan speed control loop and improves the system
acoustics.
MSB Lower Nibble
x
(TMAX)
Dynamic TMIN Fan Control Mode
MSB Upper Nibble
x
TCONTROL
Figure 17. Overview of Automatic Fan Speed Control
Using PECI Thermal Information
Table 6. PECI DATA FORMAT
S
PECI = 0
PWMMIN
x
x
x
x
Integer Value (0°C to 127°C)
There are associated high and low limits for each PECI
reading that can be programmed. The limit values take the
same format as the PECI reading. Therefore, the
programmed limits are not absolute temperatures but a
relative offset in degrees Celsius from the TCC activation
temperature. An out-of-limit event is recorded as follows:
VTT Input
The VTT voltage is monitored on Pin 8. This voltage is
also used as the reference voltage for the PECI interface. The
VTT voltage must be connected to the ADT7490 in order for
the PECI interface to be operational.
High Limit > Comparison Performed
Low Limit ≤ Comparison Performed
IMON Monitoring
The IMON input on Pin 19 can be used to monitor the IMON
output of ON Semiconductor’s VR10/VR11.1 controllers.
IMON is a voltage representation of the CPU current. Using
An out-of-limit event is recorded in the associated status
register and can be used to assert the SMBALERT pin.
www.onsemi.com
10
ADT7490
When all data bytes have been read or written, stop
conditions are established. In write mode, the master pulls
the data line high during the 10th clock pulse to assert a stop
condition. In read mode, the master device overrides the
acknowledge bit by pulling the data line high during the low
period before the ninth clock pulse; this is known as no
acknowledge. The master takes the data line low during the
low period before the 10th clock pulse, and then high during
the 10th clock pulse to assert a stop condition.
Any number of bytes of data can be transferred over the
serial bus in one operation, but it is not possible to mix read
and write in one operation because the type of operation is
determined at the beginning and cannot subsequently be
changed without starting a new operation.
In the ADT7490, write operations contain either one or
two bytes, and read operations contain one byte. To write
data to one of the device data registers or read data from it,
the address pointer register must be set so that the correct
data register is addressed. Then data can be written into that
register or read from it. The first byte of a write operation
always contains an address that is stored in the address
pointer register. If data is to be written to the device, the write
operation must contain a second data byte that is written to
the register selected by the address pointer register.
This write operation is shown in Figure 18. The device
address is sent over the bus, and then R/W is set to 0. This
is followed by two data bytes. The first data byte is the
address of the internal data register to be written to, which
is stored in the address pointer register. The second data byte
is the data to be written to the internal data register.
When reading data from a register, there are two
possibilities:
1. If the ADT7490 address pointer register value is
unknown or not the desired value, it must first be
set to the correct value before data can be read
from the desired data register. This is done by
performing a write to the ADT7490 as before, but
only the data byte containing the register address
is sent because no data is written to the register.
This is shown in Figure 19.
A read operation is then performed consisting of
the serial bus address, R/W bit set to 1, followed
by the data byte read from the data register. This is
shown in Figure 20.
2. If the address pointer register is known to be
already at the desired address, data can be read
from the corresponding data register without first
writing to the address pointer register, as shown in
Figure 20.
the IMON value and the measured VCCP value on Pin 23, the
CPU power consumption can be calculated. See the
appropriate Analog Devices flex mode data sheet for
calculations. The IMON information can be considered as an
early indication of an increase in CPU temperature.
Startup Operation
At startup, the ADT7490 turns the fans on to 100% PWM.
This allows the most robust operation at turn-on.
Serial Bus Interface
Control of the ADT7490 is carried out using the serial
system management bus (SMBus). The ADT7490 is
connected to this bus as a slave device, under the control of
a master controller. The ADT7490 has a 7-bit serial bus
address. When the device is powered up with Pin 13
(PWM3/ADDREN) high, the ADT7490 has a default
SMBus address of 0101110 or 0x2E. The read/write bit must
be added to obtain the 8-bit address. If more than one
ADT7490 is to be used in a system, each ADT7490 is placed
in address select mode by strapping Pin 13 low on powerup.
The logic state of Pin 14 then determines the device’s
SMBus address. The logic of these pins is sampled on
powerup.
The device address is monitored from powerup but not
latched until the first valid SMBus transaction, more
precisely on the low-to-high transition at the beginning of
the eighth SCL pulse, when the serial bus address byte
matches the selected slave address. The selected slave
address is chosen using the ADDREN/ADDR SELECT
pins. Any attempted changes in the address have no effect
after this.
Table 7. HARD-WIRING THE ADT7490 SMBus
DEVICE ADDRESS
Pin 13 State
Pin 14 State
0
Low (10 kW to GND)
0101100 (0x2C)
Address
0
High (10 kW Pullup)
0101101 (0x2D)
1
Don’t Care
0101110 (0x2E)
Data is sent over the serial bus in sequences of nine clock
pulses: eight bits of data followed by an acknowledge bit
from the slave device. Transitions on the data line must
occur during the low period of the clock signal and remain
stable during the high period, because a low-to-high
transition when the clock is high may be interpreted as a stop
signal. The number of data bytes that can be transmitted over
the serial bus in a single read or write operation is limited
only by what the master and slave devices can handle.
www.onsemi.com
11
ADT7490
1
9
9
1
SCL
0
SDA
1
START BY
MASTER
0
1
1
0
1
R/W
D7
D5
D4
D3
D2
D1
D0
ACK. BY
ADT7490
ACK. BY
ADT7490
FRAME 1
SERIAL BUS ADDRESS BYTE
D6
FRAME 2
ADDRESS POINTER REGISTER BYTE
1
9
SCL (CONTINUED)
SDA (CONTINUED)
D7
D6
D5
D4
D3
D2
D1
D0
ACK. BY STOP BY
ADT7490 MASTER
FRAME 3
DATA BYTE
Figure 18. Writing a Register Address to the Address Pointer Register, then Writing Data to the Selected Register
1
9
9
1
SCL
SDA
0
START BY
MASTER
1
0
1
1
1
0
FRAME 1
SERIAL BUS ADDRESS BYTE
D6
D7
R/W
ACK. BY
ADT7490
D5
D4
D3
D2
D1
D0
ACK. BY
ADT7490
FRAME 2
ADDRESS POINTER REGISTER BYTE
STOP BY
MASTER
Figure 19. Writing to the Address Pointer Register Only
9
1
1
9
SCL
SDA
0
START BY
MASTER
1
0
1
1
1
0
FRAME 1
SERIAL BUS ADDRESS BYTE
D6
D7
R/W
ACK. BY
ADT7490
D5
D4
D3
D2
D1
FRAME 2
DATA BYTE FROM ADT7490
D0
NO ACK. BY STOP BY
MASTER MASTER
Figure 20. Reading Data from a Previously Selected Register
•
•
•
•
•
•
It is possible to read a data byte from a data register
without first writing to the address pointer register if the
address pointer register is already at the correct value.
However, it is not possible to write data to a register without
writing to the address pointer register because the first data
byte of a write is always written to the address pointer
register.
In addition to supporting the send byte and receive byte
protocols, the ADT7490 also supports the read byte protocol
(see System Management Bus Specifications Rev. 2 for
more information; this document is available from the
SMBus organization).
If several read or write operations must be performed in
succession, the master can send a repeat start condition
instead of a stop condition to begin a new operation.
S: Start
P: Stop
R: Read
W: Write
A: Acknowledge
A: No acknowledge
The ADT7490 uses the following SMBus write protocols.
Send Byte
In this operation, the master device sends a single
command byte to a slave device, as follows:
1. The master device asserts a start condition on
SDA.
2. The master sends the 7-bit slave address followed
by the write bit (low).
3. The addressed slave device asserts ACK on SDA.
4. The master sends a command code.
5. The slave asserts ACK on SDA.
6. The master asserts a stop condition on SDA and
the transaction ends.
Write Operations
The SMBus specification defines several protocols for
different types of read and write operations. The ones used
in the ADT7490 are discussed here. The following
abbreviations are used in the diagrams:
www.onsemi.com
12
ADT7490
For the ADT7490, the send byte protocol is used to write
a register address to RAM for a subsequent single-byte read
from the same address. This operation is illustrated in
Figure 21.
1
2
3
SLAVE
W A
ADDRESS
S
4
5 6
REGISTER
ADDRESS
A P
1
In this operation, the master device sends a command byte
and one data byte to the slave device, as follows:
1. The master device asserts a start condition on SDA.
2. The master sends the 7-bit slave address followed
by the write bit (low).
3. The addressed slave device asserts ACK on SDA.
4. The master sends a command code.
5. The slave asserts ACK on SDA.
6. The master sends a data byte.
7. The slave asserts ACK on SDA.
8. The master asserts a stop condition on SDA, and
the transaction ends.
The byte write operation is illustrated in Figure 22.
3
4
5
REGISTER
ADDRESS
A
6
5 6
DATA
A P
Alert response address (ARA) is a feature of SMBus
devices that allows an interrupting device to identify itself
to the host when multiple devices exist on the same bus.
The SMBALERT output can be used as either an interrupt
output or an SMBALERT. One or more outputs can be
connected to a common SMBALERT line connected to the
master. If a device’s SMBALERT line goes low, the
following events occur:
1. SMBALERT is pulled low.
2. The master initiates a read operation and sends the
alert response address (ARA = 0001 100). This is
a general call address that must not be used as a
specific device address.
3. The device whose SMBALERT output is low
responds to the alert response address, and the
master reads its device address. The address of the
device is now known and can be interrogated in
the usual way.
4. If more than one device’s SMBALERT output is
low, the one with the lowest device address has
priority in accordance with normal SMBus
arbitration.
5. Once the ADT7490 has responded to the alert
response address, the master must read the status
registers, and the SMBALERT is cleared only if
the error condition is gone.
Write Byte
2
4
Alert Response Address
If the master is required to read data from the register
immediately after setting up the address, it can assert a repeat
start condition immediately after the final ACK and carry
out a single-byte read without asserting an intermediate stop
condition.
SLAVE
S ADDRESS W A
3
Figure 23. Single-byte Read from a Register
Figure 21. Setting a Register Address for
Subsequent Read
1
2
SLAVE
S ADDRESS R A
7
8
DATA A P
SMBus Timeout
The ADT7490 includes an SMBus timeout feature. If
there is no SMBus activity for 35 ms, the ADT7490 assumes
the bus is locked and releases the bus. This prevents the
device from locking or holding the SMBus expecting data.
Some SMBus controllers cannot work with the SMBus
timeout feature, so it can be disabled.
Figure 22. Single-byte Write to a Register
Read Operations
The ADT7490 uses the following SMBus read protocols.
Receive Byte
This operation is useful when repeatedly reading a single
register. The register address must be previously set up. In
this operation, the master device receives a single byte from
a slave device, as follows:
1. The master device asserts a start condition on SDA.
2. The master sends the 7-bit slave address followed
by the read bit (high).
3. The addressed slave device asserts ACK on SDA.
4. The master receives a data byte.
5. The master asserts NO ACK on SDA.
6. The master asserts a stop condition on SDA, and
the transaction ends.
Configuration Register 7 (Register 0x11)
Bit 4 (TODIS) = 0, SMBus Timeout Enabled (Default)
Bit 4 (TODIS) = 1, SMBus Timeout Disabled
Voltage Measurement Input
The ADT7490 has six external voltage measurement
channels. It can also measure its own supply voltage, VCC.
Pin 20 to Pin 23 can measure 5.0 V, 12 V, and 2.5 V
supplies, and the processor core voltage VCCP (0 V to 3.0 V
input). The 2.5 V input can be used to monitor a chipset
supply voltage in computer systems. The VCC supply
voltage measurement is carried out through the VCC pin
(Pin 4). Pin 8 measures the VTT voltage of the processor and
is the dedicated reference voltage for the PECI circuitry. The
IMON input on Pin 19 can be used to monitor the IMON
In the ADT7490, the receive byte protocol is used to read
a single byte of data from a register whose address has
previously been set by a send byte or write byte operation.
This operation is illustrated in Figure 23.
www.onsemi.com
13
ADT7490
output of ON Semiconductor’s VR11.1 controllers. IMON is
a voltage representation of the CPU current.
Table 8. VOLTAGE MEASUREMENT REGISTERS
Register
Analog-to-Digital Converter
All analog inputs are multiplexed into the on-chip,
successive approximation, analog-to-digital converter. This
ADC has a resolution of 10 bits. The basic input range is 0 V
to 2.25 V, but the inputs have built-in attenuators to allow
measurement of 2.5 V, 3.3 V, 5.0 V, 12 V, and the processor
core voltage VCCP without any external components. To
allow the tolerance of these supply voltages, the ADC
produces an output of 3/4 full scale (768 decimal or
0x300 hexadecimal) for the nominal input voltage, and
therefore, has adequate headroom to cope with
overvoltages.
+5VIN
VCC
+2.5VIN
VCCP
30 pF
30 pF
MUX
35 pF
0x00
0x21
VCCP Reading
0x00
0x22
VCC Reading
0x00
0x23
+5 VIN Reading
0x00
0x24
+12 VIN Reading
0x00
Description
Default
0x85
IMON Low Limit
0x00
0x87
IMON High Limit
0xFF
0x84
VTT Low Limit
0x00
0x86
VTT High Limit
0xFF
0x44
+2.5 VIN Low Limit
0x00
0x45
+2.5 VIN High Limit
0xFF
0x46
VCCP Low Limit
0x00
0x47
VCCP High Limit
0xFF
0x48
VCC Low Limit
0x00
0x49
VCC High Limit
0xFF
0x4A
+5.0 VIN Low Limit
0x00
0x4B
+5.0 VIN High Limit
0xFF
0x4C
+12 VIN Low Limit
0x00
0x4D
+12 VIN High Limit
0xFF
Extended Resolution Registers
45 kW
Voltage measurements can be made with higher accuracy
using the extended resolution registers (0x1F, 0x76, and
0x77). Whenever the extended resolution registers are read,
the corresponding data in the voltage measurement registers
(0x1D, 0x1E, and 0x20 to 0x24) is locked until their data is
read. That is, if extended resolution is required, the extended
resolution register must be read first, immediately followed
by the appropriate voltage measurement register.
30 pF
45 kW
45 kW
0x00
+2.5 VIN Reading
When the ADC is running, it samples and converts a
voltage input in 0.7 ms and averages 16 conversions to
reduce noise; a measurement takes nominally 11 ms.
17.5 kW
94 kW
VTT
30 pF
45 kW
52.5 kW
IMON
30 pF
68 kW
94 kW
VTT Reading
0x20
Register
93 kW
71 kW
0x1E
Table 9. VOLTAGE LIMIT REGISTERS
120 kW
47 kW
0x00
Associated with each voltage measurement channel is a
high and low limit register. Exceeding the programmed high
or low limit causes the appropriate status bit to be set.
Exceeding either limit can also generate SMBALERT
interrupts.
The internal structure for the analog inputs is shown in
Figure 24 . The input circuit consists of an input protection
diode, an attenuator, plus a capacitor to form a first-order
low-pass filter that gives input immunity to high frequency
noise.
20 kW
Default
IMON Reading
Voltage Limit Registers
Input Circuitry
+12VIN
Description
0x1D
30 pF
Figure 24. Analog Inputs Structure
www.onsemi.com
14
ADT7490
Additional ADC Functions for Voltage Measurements
Table 11. BYPASSING INDIVIDUAL VOLTAGE INPUT
ATTENUATORS
A number of other functions are available on the
ADT7490 to offer the system designer increased flexibility.
The functions described in the following sections are
enabled by setting the appropriate bit in Configuration
Register 2.
Configuration Register 4 (0x7D)
Bit No.
Configuration Register 2 (Register 0x73)
Bit 4 (AVG) = 1, Averaging Off.
Bit 5 (ATTN) = 1, Bypass Input Attenuators.
Bit 6 (CONV) = 1, Single-channel Convert Mode.
Bypass +2.5 VIN Attenuator
[5]
Bypass VCCP Attenuator
[6]
Bypass +5 VIN Attenuator
[7]
Bypass +12 VIN Attenuator
While single-channel mode is intended as a test mode that
can be used to increase sampling times for a specific
channel, therefore helping to analyze that channel’s
performance in greater detail, it can also have other
applications.
Setting Bit 6 of Configuration Register 2 (0x73) places
the ADT7490 into single-channel ADC conversion mode. In
this mode, the ADT7490 can read a single voltage channel
only. The selected voltage input is read every 0.7 ms. The
appropriate ADC channel is selected by writing to Bits [7:4]
of the TACH1 minimum high byte register (0x55).
For each voltage/temperature measurement read from a
value register, 16 readings have actually been made
internally and the results averaged before being placed into
the value register. When faster conversions are needed,
setting Bit 4 (AVG) of Configuration Register 2 (0x73)
turns averaging off. This effectively gives a reading that is
16 times faster, but the reading can be noisier. The default
round-robin cycle time takes 146.5 ms.
Table 10. CONVERSION TIME WITH AVERAGING
DISABLED
Table 12. PROGRAMMING SINGLE-CHANNEL ADC
MODE
Measurement Time (ms)
Voltage Channels
[4]
Single-channel ADC Conversion
Turn-off Averaging
Channel
Channel Attenuated
0.7
Bits [7:4], Register 0x55
Remote Temperature 1
7
0000
+2.5 VIN
Remote Temperature 2
7
0001
1.3
VCCP
0010
VCC
When Bit 7 (ExtraSlow) of Configuration Register 6
(0x10) is set, the default round-robin cycle time increases to
240 ms.
0011
+5 VIN
0100
+12 VIN
0101
Remote 1 Temperature
Bypass All Voltage Input Attenuators
0110
Local Temperature
Setting Bit 5 of Configuration Register 2 (0x73) removes
the attenuation circuitry from the 2.5 VIN, VCCP, VCC,
5 VIN, and 12 VIN inputs. This allows the user to directly
connect external sensors or rescale the analog voltage
measurement inputs for other applications. The input range
of the ADC without the attenuators is 0 V to 2.25 V.
0111
Remote 2 Temperature
1000
VTT
1001
IMON
Local Temperature
Channel Selected (Note 1)
1. In the process of configuring single-channel ADC conversion
mode, the TACH1 minimum high byte is also changed, possibly
trading off TACH1 minimum high byte functionality with
single-channel mode functionality.
Bypass Individual Voltage Input Attenuators
Bits [7:4] of Configuration Register 4 (0x7D) can be used
to bypass individual voltage channel attenuators.
www.onsemi.com
15
ADT7490
Table 13. 10-BIT ADC OUTPUT CODE VS. VIN
Input Voltage
+12 VIN
+5 VIN
VCC (3.3 VIN)
ADC Output
+2.5 VIN
VCCP
VTT/IMON
Decimal
Binary (10 Bits)
<0.0156
<0.0065
<0.0042
<0.0032
<0.00293
<0.00220
0
00000000 00
0.0156 to
0.0312
0.0065 to
0.0130
0.0042 to
0.0085
0.0032 to
0.0065
0.0293 to
0.0058
0.00220 to
0.00440
1
00000000 01
0.0312 to
0.0469
0.0130 to
0.0195
0.0085 to
0.0128
0.0065 to
0.0097
0.0058 to
0.0087
0.00440 to
0,00660
2
00000000 10
0.0469 to
0.0625
0.0195 to
0.0260
0.0128 to
0.0171
0.0097 to
0.0130
0.0087 to
0.0117
0,00660 to
0.00881
3
00000000 11
0.0625 to
0.0781
0.0260 to
0.0325
0.0171 to
0.0214
0.0130 to
0.0162
0.0117 to
0.0146
0.00881 to
0.01100
4
00000001 00
0.0781 to
0.0937
0.0325 to
0.0390
0.0214 to
0.0257
0.0162 to
0.0195
0.0146 to
0.0175
0.01100 to
0.01320
5
00000001 01
0.0937 to
0.1093
0.0390 to
0.0455
0.0257 to
0.0300
0.0195 to
0.0227
0.0175 to
0.0205
0.01320 to
0.01541
6
00000001 10
0.1093 to
0.1250
0.0455 to
0.0521
0.0300 to
0.0343
0.0227 to
0.0260
0.0205 to
0.0234
0.01541 to
0.01761
7
00000001 11
0.1250 to
0.14060
0.0521 to
0.0586
0.0343 to
0.0386
0.0260 to
0.0292
0.0234 to
0.0263
0.01761 to
0.01981
8
00000010 00
−
−
−
−
−
−
−
−
4.0000 to
4.0156
1.6675 to
1.6740
1.1000 to
1.1042
0.8325 to
0.8357
0.7500 to
0.7529
0.5636 to
0.5658
256
01000000 00
(1/4 scale)
−
−
−
−
−
−
−
−
8.0000 to
8.0156
3.3300 to
3.3415
2.2000–2.204
2
1.6650 to
1.6682
1.5000 to
1.5029
1.1272 to
1.1294
512
10000000 00
(1/2 scale)
−
−
−
−
−
−
−
−
12.0000 to
12.0156
5.0025 to
5.0090
3.3000 to
3.3042
2.4975 to
2.5007
2.2500 to
2.2529
1.6809 to
1.6930
768
11000000 00
(3/4 scale)
−
−
−
−
−
−
−
−
15.8281 to
15.8437
6.5983 to
6.6048
4.3527 to
4.3570
3.2942 to
3.2974
2.9677 to
2.9707
2.2301 to
2.2323
1013
11111101 01
15.8437 to
15.8593
6.6048 to
6.6113
4.3570 to
4.3613
3.2974 to
3.3007
2.9707 to
2.9736
2.2323 to
2.2346
1014
11111101 10
15.8593 to
15.8750
6.6113 to
6.6178
4.3613 to
4.3656
3.3007 to
3.3039
2.9736 to
2.9765
2.2346 to
2.2368
1015
11111101 11
15.8750 to
15.8906
6.6178 to
6.6244
4.3656 to
4.3699
3.3039 to
3.3072
2.9765 to
2.9794
2.2368 to
2.23899
1016
11111110 00
15.8906 to
15.9062
6.6244 to
6.6309
4.3699 to
4.3742
3.3072 to
3.3104
2.9794 to
2.9824
2,23899 to
2.2412
1017
11111110 01
15.9062 to
15.9218
6.6309 to
6.6374
4.3742 to
4.3785
3.3104 to
3.3137
2.9824 to
2.9853
2.2412 to
2.2434
1018
11111110 10
15.9218 to
15.9375
6.6374 to
6.4390
4.3785 to
4.3828
3.3137 to
3.3169
2.9853 to
2.9882
2.2434 to
2.2456
1019
11111110 11
15.9375 to
15.9531
6.6439 to
6.6504
4.3828 to
4.3871
3.3169 to
3.3202
2.9882 to
2.9912
2.2456 to
2.2478
1020
11111111 00
15.9531 to
15.9687
6.6504 to
6.6569
4.3871 to
4.3914
3.3202 to
3.3234
2.9912 to
2.9941
2.2478 to
2.25
1021
11111111 01
15.9687 to
15.9843
6.6569 to
6.6634
4.3914 to
4.3957
3.3234 to
3.3267
2.9941 to
2.9970
2.25 to
2.2522
1022
11111111 10
>15.9843
>6.6634
>4.3957
>3.3267
>2.9970
>2.2522
1023
1111111111 1
www.onsemi.com
16
ADT7490
Temperature Measurement
PECI Offset Registers
The ADT7490 has four temperature measurement
channels: one local, two remote thermal diodes, and a PECI.
The local and thermal diode readings are analog temperature
measurements, whereas PECI is a digital temperature
reading.
Each PECI reading has a dedicated offset register to
calibrate the PECI measurement and account for errors in
the temperature reading. The LSBs add a 1°C offset to the
temperature reading so that the 8-bit register effectively
allows temperature offsets of up to ±128°C with a resolution
of 1°C.
PECI Temperature Measurement
Register 0x94, PECI0 Offset
The PECI interface is a dedicated thermal interface. The
CPU temperature measurement is carried out internally in
the CPU. This information is digitized and transferred to the
ADT7490 via the PECI interface. The ADT7490 is a PECI
host device and therefore, polls the CPU for thermal
information.
The PECI measurement differs from traditional thermal
diode temperature measurements in that the measurement is
a relative value instead of an absolute value. The PECI
reading is a negative value that indicates how close the CPU
temperature is from the thermal throttling or TCC point of the
CPU.
The ADT7490 records and uses the PECI measurement
for fan control in its relative format. Therefore, care must be
taken in programming the relevant limits and fan control
parameters in the PECI format. Refer to the PECI Input
section and Table 6 for further PECI information.
PECI monitoring is enabled on the ADT7490 by setting
the PECI monitoring bit in Configuration Register 1
(Register 0x40, Bit 4). The ADT7490 can measure the
temperature of up to four dual-core CPUs. The number of
CPUs in the system that provide PECI information is set in
Bits [7:6] of Register 0x88. Each CPU is distinguished by
the PECI address. The number of domains, or domain count,
per CPU address must also be programmed into the
ADT7490. The ADT7490 reads the temperature of both
domains per CPU, however, only the PECI value of the
hottest domain is recorded in the PECI value register.
Register 0x95, PECI1 Offset
Register 0x96, PECI2 Offset
Register 0x97, PECI3 Offset
PECI Data Smoothing
The PECI smoothing interval is programmed in PECI
Configuration Register 1 (0x36). Bits [2:0] of Register 0x36
set the duration over which the PECI data being read by the
ADT7490 is averaged. These bits set the duration over
which smoothing is carried out on the PECI data read. The
refresh rate in the PECI value registers is the same as the
smoothing interval programmed.
The smoothing interval is calculated using the following
formula:
Smoothing Interval + #reads ǒt BIT 67 #CPU ) t IDLEǓ
(eq. 1)
where:
#reads is the number of readings defined in Register 0x36,
Bits [2:0]
tBIT is the negotiated bit rate.
67 is the number of bits in each PECI reading.
#CPU is the number of CPUs providing PECI data
(1 to 4).
tIDLE = 14 ms, the delay between consecutive reads.
PECI3 domains: Register 0x88, Bit 3
For example,
#reads = 4096
tBIT = 1 ms (1 MHz speed)
#CPU = 1
Smoothing Interval = 331 ms = PECI reading refresh rate
PECI Reading Registers
PECI Error Codes
PECI0 domains: Register 0x36, Bit 3
PECI1 domains: Register 0x88, Bit 5
PECI2 domains: Register 0x88, Bit 4
There are two different error conditions for PECI data,
PECI data errors, and PECI bus communications errors.
Table 14 describes the two different error conditions. If the
ADT7490 reads an error code (0x8000 to 0x8003) from the
CPU over the PECI interface, Bit 1 is set in Interrupt
Status 3 register (0x43), indicating a data error. The value of
the error code is not included in the PECI value averaging
sum. This means that a value of 0x00 is added to the PECI
sum when an error code is recorded. The error code is not
reported in the appropriate PECI value register. If an invalid
FCS is recorded by the ADT7490, Bit 2 is set in the Interrupt
Status 3 register (0x43), indicating a communications error.
An alert is generated on the SMBALERT pin when either or
both of these status bits are asserted.
Register 0x33, PECI0: PECI Reading from CPU Address 0x30
Register 0x1A, PECI1: PECI Reading from CPU Address 0x31
Register 0x1B, PECI2: PECI Reading from CPU Address 0x32
Register 0x1C, PECI3: PECI Reading from CPU Address 0x33
PECI Limit Registers
Each PECI measurement shares the same high and low
limits.
Register 0x34, PECI Low Limit = 0x81 Default
Register 0x35, PECI High Limit = 0x00 Default
www.onsemi.com
17
ADT7490
Table 14. PECI ERROR INDICATORS
PECI Data
Description
Table 16. REPLACE MODE TEMPERATURE
REGISTERS
Action
0x8000 to
0x8003
PECI Data Error
Bit 1 of Register
0x43 is set to 1
Invalid
FCS
PECI Communications Error
Bit 2 of Register
0x43 is set to 1
Register Name
Each PECI channel also has an associated status bit to
indicate if the PECI high or low limits have been exceeded.
An alert is generated on the SMBALERT pin when these
status bits are asserted.
Table 15. PECI STATUS BITS
Channel
Register
Bit
PECI0
0x43
0
PECI1
0x81
3
PECI2
0x81
4
PECI3
0x81
5
Temperature Data REPLACE Mode
The REPLACE mode is configured by setting Bit 4 of
Register 0x36. In this mode, the data in the existing
Remote 1 registers are replaced by PECI0 data. This is a
legacy mode that allows the thermal data from CPU1 to be
stored in the same registers as in the ADT7476A. This
reduces the software changes in systems transitioning from
CPUs with thermal diodes to CPUs with a PECI interface.
However, note that even though the associated registers are
swapped, the correct data format (PECI vs. absolute
temperature, see Table 6) must be written to and interpreted
from these registers.
Remote 1
Default
PECI0 Default
Value Register
Reg. 0x25
Reg. 0x33
Low Limit
Reg. 0x4E
Reg. 0x34
High Limit
Reg. 0x4F
Reg. 0x35
TMIN
Reg. 0x67
Reg. 0x3B
TRANGE
Reg. 0x5F,
Bits [7:4]
Reg. 0x3C,
Bits [7:4]
Enhanced Acoustics
Reg. 0x62,
Bits [2:0]
Reg. 0x3C,
Bits [2:0]
Enhanced Acoustics
Enable
Reg. 0x62, Bit 3
Reg. 0x3C, Bit 3
THERM TCONTROL
Reg. 0x6A
Reg. 0x3D
TMIN Hysteresis
Reg. 0x6D,
Bits [7:4]
Reg. 0x6D,
Bits [3:0]
(Note 1)
Reg. 0x6E,
Bits [3:0]
Reg. 0x6E,
Bits [7:4]
(Note 1)
Temperature offset
Reg. 0x70
Reg. 0x94
Operating Point for
Dynamic TMIN
Reg. 0x8B
Reg. 0x8A
1. In REPLACE mode, the Remote 2 and local temperature
hysteresis values are swapped.
In REPLACE mode, the temperature zone controlling the
relevant PWM output are also swapped from Remote 1 to
PECI0. The swap of control only occurs if the default
behavior
setting
for
Register 0x5C
Bits [7:5],
Register 0x5D Bits [7:5] or Register 0x5E Bits [7:5] is 000.
Local Temperature Measurement
The ADT7490 contains an on-chip band gap temperature
sensor whose output is digitized by the on-chip 10-bit ADC.
The 8-bit MSB temperature data is stored in the local
temperature register (Address 0x26). Because both positive
and negative temperatures can be measured, the temperature
data is stored in Offset 64 format or twos complement
format, as shown in Table 17 and Table 18. Theoretically,
the temperature sensor and ADC can measure temperatures
from −128°C to +127°C (or −64°C to +191°C in the
extended temperature range) with a resolution of 0.25°C.
However, this exceeds the operating temperature range of
the device, so local temperature measurements outside the
ADT7490 operating temperature range are not possible.
Notes
In Table 16, registers listed under the Remote 1 Default
column are in absolute temperature format by default and
are in PECI format in REPLACE mode. Registers listed
under the PECI0 Default column are in PECI format by
default and in absolute temperature format in REPLACE
mode.
www.onsemi.com
18
ADT7490
it could equally be a discrete transistor, such as a
2N3904/2N3906.
If a discrete transistor is used, the collector is not grounded
and should be linked to the base. If a PNP transistor is used,
the base is connected to the D– input and the emitter to the
D+ input. If an NPN transistor is used, the emitter is
connected to the D– input and the base to the D+ input.
Figure 25 and Figure 26 show how to connect the ADT7490
to an NPN or PNP transistor for temperature measurement.
Table 17. TWOS COMPLEMENT TEMPERATURE DATA
FORMAT
Temperature
Digital Output (10-bit) (Note 1)
–128°C
1000 0000 00 (Diode Fault)
–63°C
1100 0001 00
–50°C
1100 1110 00
–25°C
1110 0111 00
–10°C
1111 0110 00
0°C
0000 0000 00
10.25°C
0000 1010 01
25.5°C
0001 1001 10
50.75°C
0011 0010 11
75°C
0100 1011 00
100°C
0110 0100 00
125°C
0111 1101 00
127°C
0111 1111 00
ADT7490
2N3904
NPN
2N3906
PNP
Table 18. OFFSET 64 DATA FORMAT
0000 0000 00 (Diode Fault)
–63°C
0000 0001 00
–1°C
0011 1111 00
0°C
0100 0000 00
1°C
0100 0001 00
10°C
0100 1010 00
25°C
0101 1001 00
50°C
0111 0010 00
75°C
1000 1001 00
100°C
1010 0100 00
125°C
1011 1101 00
191°C
1111 1111 00
ADT7490
D+
D−
Figure 26. Measuring Temperature by Using
a PNP Transistor
Digital Output (10-bit) (Note 1)
–64°C
D−
Figure 25. Measuring Temperature by Using
an NPN Transistor
1. Bold numbers denote 2 LSBs of measurement in the Extended
Resolution 2 register (Register 0x77) with 0.25°C resolution.
Temperature
D+
To prevent ground noise from interfering with the
measurement, the more negative terminal of the sensor is not
referenced to ground, but is biased above ground by an
internal diode at the D− input. C1 can optionally be added as
a noise filter (recommended maximum value of 1,000 pF).
However, a better option in noisy environments is to add a
filter, as described in the section.
Remote Temperature Measurement
The ADT7490 can measure the temperature of two remote
diode sensors or diode-connected transistors connected to
Pin 10 and Pin 11, or Pin 12 and Pin 13.
The forward voltage of a diode or diode-connected
transistor operated at a constant current exhibits a negative
temperature coefficient of about −2 mV/°C. Unfortunately,
the absolute value of VBE varies from device to device, and
individual calibration is required to null this out. Therefore,
the technique is unsuitable for mass production. The
technique used in the ADT7490 is to measure the change in
VBE when the device is operated at three different currents.
This is given by:
1. Bold numbers denote 2 LSBs of measurement in the Extended
Resolution 2 register (Register 0x77) with 0.25°C resolution.
Thermal Diode Temperature Measurement Method
A simple method of measuring temperature is to exploit
the negative temperature coefficient of a diode, measuring
the base-emitter voltage (VBE) of a transistor operated at
constant current. Unfortunately, this technique requires
calibration to null out the effect of the absolute value of VBE,
which varies from device to device.
The technique used in the ADT7490 is to measure the
change in VBE when the device is operated at three different
currents. Previous devices have used only two operating
currents, but the use of a third current allows automatic
cancellation of resistances in series with the external
temperature sensor.
Figure 28 shows the input signal conditioning used to
measure the output of an external temperature sensor. This
figure shows the external sensor as a substrate transistor, but
DV BE + kT
q
In(N)
(eq. 2)
where:
k is the Boltzmann constant.
q is the charge on the carrier.
T is the absolute temperature in Kelvin.
N is the ratio of the two currents.
To measure DVBE, the operating current through the
sensor is switched among three related currents. N1 × I and
N2 × I are different multiples of the current I, as shown in
Figure 27. The currents through the temperature diode are
www.onsemi.com
19
ADT7490
switched between I and N1 × I, giving DVBE1, and then
between I and N2 × I, giving DVBE2. The temperature can
then be calculated using the two DVBE measurements. This
method can also cancel the effect of any series resistance on
the temperature measurement.
The resulting DVBE waveforms are passed through a
65 kHz low-pass filter to remove noise and then to a
chopper-stabilized amplifier. This amplifies and rectifies the
waveform to produce a dc voltage proportional to DVBE.
The ADC digitizes this voltage, and a temperature
I
N2 × I
N1 × I
measurement is produced. To reduce the effects of noise,
digital filtering is performed by averaging the results of 16
measurement cycles.
The results of remote temperature measurements are
stored in 10-bit, twos complement format, as listed in
Table 17. The extra resolution for the temperature
measurements is held in the Extended Resolution Register 2
(0x77). This gives temperature readings with a resolution of
0.25°C.
IBIAS
VCC
VOUT+
D+
REMOTE
SENSING
TRANSISTOR
To ADC
D−
VOUT−
LOW-PASS FILTER
fC = 65 kHz
Figure 27. Signal Conditioning for Remote Diode Temperature Sensors
Series Resistance Cancellation
the remote sensor is automatically canceled from the
temperature result.
The construction of a filter allows the ADT7490 and the
remote temperature sensor to operate in noisy environments.
Figure 28 shows a low-pass RC filter with the following
values:
Parasitic resistance to the ADT7490 D+ and D− inputs
(seen in series with the remote diode) is caused by a variety
of factors, including PCB track resistance and track length.
This series resistance appears as a temperature offset in the
remote sensor’s temperature measurement. This error
typically causes a 0.5°C offset per ohm of parasitic
resistance in series with the remote diode.
The ADT7490 automatically cancels out the effect of this
series resistance on the temperature reading, giving a more
accurate result without the need for user characterization of
this resistance. The ADT7490 is designed to automatically
cancel, typically up to 1.5 kW of resistance. By using an
advanced temperature measurement method, this is
transparent to the user. This feature allows resistances to be
added to the sensor path to produce a filter, allowing the part
to be used in noisy environments.
R + 100 W, C + 1 nF
(eq. 3)
This filtering reduces both common-mode noise and
differential noise.
100 W
REMOTE
TEMPERATURE
SENSOR
100 W
D+
1 nF
D−
Figure 28. Filter between Remote Sensor and ADT7490
Factors Affecting Diode Accuracy
Noise Filtering
For temperature sensors operating in noisy environments,
previous practice was to place a capacitor across the D+ pin
and the D− pin to help combat the effects of noise. However,
large capacitance affect the accuracy of the temperature
measurement, leading to a recommended maximum
capacitor value of 1,000 pF. This capacitor reduces the
noise, but does not eliminate it, which makes using the
sensor difficult in a very noisy environment.
The ADT7490 has a major advantage over other devices
for eliminating the effects of noise on the external sensor.
Using the series resistance cancellation feature, a filter can
be constructed between the external temperature sensor and
the part. The effect of any filter resistance seen in series with
Remote Sensing Diode
The ADT7490 is designed to work with either substrate
transistors built into processors or discrete transistors.
Substrate transistors are generally PNP types with the
collector connected to the substrate. Discrete types can be
either PNP or NPN transistors connected as a diode
(base-shorted to the collector). To reduce the error due to
variations in both substrate and discrete transistors, a
number of factors should be taken into consideration:
• The ideality factor, nf, of the transistor is a measure of
the deviation of the thermal diode from ideal behavior.
The ADT7490 is trimmed for an nf value of 1.008. Use
www.onsemi.com
20
ADT7490
Constant high frequency noise usually attenuates or
increases temperature measurements by a linear, constant
value.
The ADT7490 has temperature offset registers at
Address 0x70, Address 0x71, and Address 0x72 for the
Remote 1, local, and Remote 2 temperature channels,
respectively. By performing a one-time calibration of the
system, the user can determine the offset caused by system
board noise and null it out using the offset registers. The
offset registers automatically add a twos complement 8-bit
reading to every temperature measurement.
The temperature offset range and resolution is selected by
setting Bit 1 of Register 0x7C. This ensures that the readings
in the temperature measurement registers are as accurate as
possible. Setting this bit to 0 means the LSBs add 0.5°C
offset to the temperature reading, so the 8-bit register
effectively allows temperature offsets from −63°C to +64°C
with a resolution of 0.5°C. Setting this bit to 1 means the
LSBs add 1°C offset to the temperature reading, so the 8-bit
register effectively allows temperature offsets of up to
−63°C to +127°C with a resolution of 1°C. For the PECI
offset registers, the resolution is always 1°C.
the following equation to calculate the error introduced
at a temperature T (°C) when using a transistor whose
nf does not equal 1.008. Refer to the data sheet for the
related CPU to obtain the nf values.
(eq. 4)
DT + (nf * 1.008)ń1.008 ǒ273.15 K ) TǓ
•
To factor this in, the user can write the DT value to the
offset register. The ADT7490 automatically adds it to
or subtracts it from the temperature measurement.
Some CPU manufacturers specify the high and low
current levels of the substrate transistors. The high
current level of the ADT7490, IHIGH, is 192 mA and the
low level current, ILOW, is 12 mA. If the ADT7490
current levels do not match the current levels specified
by the CPU manufacturer, it may be necessary to
remove an offset. The CPU’s data sheet advises
whether this offset needs to be removed and how to
calculate it. This offset can be programmed to the offset
register. It is important to note that if more than one
offset must be considered, the algebraic sum of these
offsets must be programmed to the offset register.
If a discrete transistor is used with the ADT7490, the best
accuracy is obtained by choosing devices according to the
following criteria:
• Base-emitter voltage greater than 0.25 V at 12 mA at the
highest operating temperature.
• Base-emitter voltage less than 0.95 V at 192 mA at the
lowest operating temperature.
• Base resistance less than 100 W.
• Small variation in hFE (such as 50 to 150) that indicates
tight control of VBE characteristics.
Table 19. TEMPERATURE OFFSET REGISTERS
Transistors, such as 2N3904, 2N3906, or equivalents in
SOT−23 packages, are suitable devices to use.
Register
Description
Default
0x70
Remote 1 Temperature Offset
0x00 (0°C)
0x71
Local Temperature Offset
0x00 (0°C)
0x72
Remote 2 Temperature Offset
0x00 (0°C)
0x94
PECI0 Temperature Offset
0x00 (0°C)
0x95
PECI1 Temperature Offset
0x00 (0°C)
0x96
PECI2 Temperature Offset
0x00 (0°C)
0x97
PECI3 Temperature Offset
0x00 (0°C)
Temperature Measurement Limit Registers
Associated with each temperature measurement channel
are high and low limit registers. Exceeding the programmed
high or low limit causes the appropriate status bit to be set.
Exceeding either limit can also generate SMBALERT
interrupts (depending on the way the interrupt mask register
is programmed and assuming that SMBALERT is set as an
output on the appropriate pin).
Reading Temperature from the ADT7490
It is important to note that temperature can be read from
the ADT7490 as an 8-bit value (with 1°C resolution) or as
a 10-bit value (with 0.25°C resolution). If only 1°C
resolution is required, the temperature readings can be read
back at any time and in no particular order.
If the 10-bit measurement is required, it involves a
2-register read for each measurement. The Extended
Resolution 2 register (0x77) should be read first. This causes
all temperature reading registers to be frozen until all
temperature reading registers have been read from. This
prevents an MSB reading from being updated while its two
LSBs are being read and vice versa.
Additional ADC Functions for Temperature
Measurement
A number of other functions are available on the
ADT7490 to offer the system designer increased flexibility.
Turn-off Averaging
For each temperature measurement read from a value
register, 16 readings have actually been made internally, and
the results averaged, before being placed into the value
register. Sometimes it is necessary to take a very fast
measurement. Setting Bit 4 of Configuration Register 2
(0x73) turns averaging off. The default round-robin cycle
time with averaging off is a maximum of 23 ms.
Nulling Out Temperature Errors
As CPUs run faster, it becomes more difficult to avoid
high frequency clocks when routing the D+/D− traces
around a system board. Even when recommended layout
guidelines are followed, some temperature errors may still
be attributable to noise coupled onto the D+/D− lines.
www.onsemi.com
21
ADT7490
setting the BOOST bit in Configuration Register 3, Bit 2
(0x78). The hysteresis value for the THERM temperature
limit is the value programmed into the hysteresis registers
(0x6D and 0x6E). The default hysteresis value is 4°C.
Table 20. CONVERSION TIME WITH AVERAGING
DISABLED
Channel
Measurement Time (ms)
Voltage Channels
0.7
Remote Temperature 1
7
Remote Temperature 2
7
Local Temperature
THERM LIMIT
TEMPERATURE
1.3
When Bit 7 of Configuration Register 6 (0x10) is set, the
default round-robin cycle time increases to a maximum of
193 ms.
FANS
Channel
THERM can be disabled by setting Bit 2 of Configuration
Register 4 (0x7D). THERM can also be disabled by:
• In Offset 64 mode, writing −64°C to the appropriate
THERM temperature limit.
• In twos complement mode, writing −128°C to the
appropriate THERM temperature limit.
Measurement Time (ms)
11
Remote Temperature
39
Local Temperature
12
Single-channel ADC Conversions
Limits, Status Registers, and Interrupts
Setting Bit 6 of Configuration Register 2 (Register 0x73)
places the ADT7490 into single-channel ADC conversion
mode. In this mode, the ADT7490 can be made to read a
single temperature channel only. The appropriate ADC
channel is selected by writing to Bits [7:4] of the TACH1
Minimum High Byte register (0x55).
Limit Values
Associated with each measurement channel on the
ADT7490 are high and low limits. These can form the basis of
system status monitoring; a status bit can be set for any
out-of-limit condition and is detected by polling the device.
Alternatively, SMBALERT interrupts can be generated to flag
out-of-limit conditions to a processor or micro-controller.
Table 22. PROGRAMMING SINGLE-CHANNEL ADC
MODE FOR TEMPERATURES
Bits [7:4], Register 0x55
8-bit Limits
Channel Selected
Remote 1 Temperature
0101
Local Temperature
0110
Remote 2 Temperature
0111
100%
Figure 29. THERM Temperature Limit Operation
Table 21. CONVERSION TIME WITH AVERAGING
ENABLED
Voltage Channels
HYSTERESIS (°C)
The following is a list of 8-bit limits on the ADT7490:
Table 23. VOLTAGE LIMIT REGISTERS
Register
Description
Default
Configuration Register 2 (Register 0x73)
0x44
+2.5 VIN Low Limit
0x00
Bit 4 (AVG) = 1, Averaging Off.
Bit 6 (CONV) = 1, Single-channel Convert Mode.
0x45
+2.5 VIN High Limit
0xFF
0x46
VCCP Low Limit
0x00
0x47
0xFF
Overtemperature Events
VCCP High Limit
0x48
VCC Low Limit
0x00
0x49
VCC High Limit
0xFF
0x4A
+5 VIN Low Limit
0x00
0x4B
+5 VIN High Limit
0xFF
0x4C
+12 VIN Low Limit
0x00
0x4D
+12 VIN High Limit
0xFF
0x84
VTT Low Limit
0x00
0x86
VTT High Limit
0xFF
0x85
IMON Low Limit
0x00
0x87
IMON High Limit
0xFF
Overtemperature events on any of the temperature
channels can be detected and dealt with automatically in
automatic fan speed control mode. Register 0x6A to
Register 0x6C are the THERM temperature limits for the
local and remote diode temperature channels. The
equivalent PECI limit is TCONTROL in Register 0x3D. When
a temperature exceeds its THERM temperature limit, all
PWM outputs run at 100% duty cycle (default). This can be
changed to maximum PWM duty cycle as programmed in
Register 0x38, Register 0x39, and Register 0x3A, by setting
Bit 3 of Register 0x7D.
The fans run at this speed until the temperature drops
below THERM minus hysteresis. This can be disabled by
www.onsemi.com
22
ADT7490
Voltage and temperature channels use a window
comparator for error detecting and, therefore, have high and
low limits. Fan speed measurements use only a low limit.
Table 24. TEMPERATURE LIMIT REGISTERS
Register
Description
Default
0x4E
Remote 1 Temperature Low Limit
0x81
0x4F
Remote 1 Temperature High Limit
0x7F
0x6A
Remote 1 THERM Temp. Limit
0x64
0x50
Local Temperature Low Limit
0x81
0x51
Local Temperature High Limit
0x7F
0x6B
Local THERM Temperature Limit
0x64
0x52
Remote 2 Temperature Low Limit
0x81
0x53
Remote 2 Temperature High Limit
0x7F
0x6C
Remote 2 THERM Temp. Limit
0x64
0x34
PECI Low Limit
0x81
0x35
PECI High Limit
0x00
0x3D
PECI TCONTROL Limit
0x00
Analog Monitoring Cycle Time
The analog monitoring cycle begins when a 1 is written to
the start bit (Bit 0) of Configuration Register 1 (0x40). The
ADC measures each analog input in turn and, as each
measurement is completed, the result is automatically stored
in the appropriate value register. This round-robin
monitoring cycle continues unless disabled by writing a 0 to
Bit 0 of Configuration Register 1.
As the ADC is normally left to free-run in this manner, the
time taken to monitor all the analog inputs is normally not
of interest, because the most recently measured value of any
input can be read out at any time. For applications where the
monitoring cycle time is important, it can easily be
calculated.
Table 25. THERM TIMER LIMIT REGISTER
Register
0x7A
Description
THERM Timer Limit
•
•
•
•
Default
0x00
16-bit Limits
The fan TACH measurements are 16-bit results. The fan
TACH limits are also 16 bits, consisting of a high byte and
low byte. Only high limits exist for fan TACHs because fans
running under speed or stalled are normally the only
conditions of interest. Because the fan TACH period is
actually being measured, exceeding the limit indicates a
slow or stalled fan.
As mentioned previously, the ADC performs round-robin
conversions and takes 11 ms for each voltage measurement,
12 ms for a local temperature reading, and 39 ms for each
remote temperature reading. The total monitoring cycle time
for averaged voltage and temperature monitoring is,
therefore, nominally
(7
Table 26. FAN LIMIT REGISTERS
Register
Description
The total number of channels measured consists of
Six Dedicated Supply Voltage Inputs
Supply Voltage (VCC Pin)
Local Temperature
Two Remote Temperatures
TACH1 Minimum Low Byte
0xFF
0x55
TACH1 Minimum High Byte
0xFF
0x56
TACH2 Minimum Low Byte
0xFF
0x57
TACH2 Minimum High Byte
0xFF
0x58
TACH3 Minimum Low Byte
0xFF
0x59
TACH3 Minimum High Byte
0xFF
0x5A
TACH4 Minimum Low Byte
0xFF
0x5B
TACH4 Minimum High Byte
0xFF
39) + 167 ms
(eq. 5)
Fan TACH measurements and PECI thermal measurements
are made in parallel and are not synchronized with the analog
measurements in any way.
Default
0x54
11) ) 12 ) (2
Interrupt Status Registers
The results of limit comparisons are stored in Interrupt
Status Register 1 to Interrupt Status Register 4. The status
register bit for each channel reflects the status of the last
measurement and limit comparison on that channel. If a
measurement is within limits, the corresponding interrupt
status register bit is cleared to 0. If the measurement is out of
limit, the corresponding interrupt status register bit is set to 1.
The state of the various measurement channels can be
polled by reading the interrupt status registers over the serial
bus. In Bit 7 (OOL) of Interrupt Status Register 1 (0x41), a
Logic 1 indicates an out-of-limit event has been flagged in
Interrupt Status Register 2. This means the user also needs to
read Interrupt Status Register 2. There is a similar OOL bit in
Interrupt Status Register 2 and Interrupt Status Register 3,
indicating an out-of-limit event in the next status register.
Alternatively, Pin 10 or Pin 14 can be configured as an
SMBALERT output. This hard interrupt automatically
notifies the system supervisor of an out-of-limit condition.
Reading the interrupt status registers clears the appropriate
status bit as long as the error condition that caused the
Out-of-Limit Comparisons
Once all limits have been programmed, the ADT7490 can
be enabled for monitoring. The ADT7490 measures all
voltage and temperature measurements in round-robin
format and sets the appropriate status bit to indicate
out-of-limit conditions. TACH measurements are not part of
this round-robin cycle. Comparisons are done differently
depending on whether the measured value is being
compared to a high or low limit.
High Limit > Comparison Performed
Low Limit ≤ Comparison Performed
www.onsemi.com
23
ADT7490
dedicated alert pin. However, if one of these masked
interrupt sources goes out of limit, its associated interrupt
status bit is set in the interrupt status registers.
Full details of the Interrupt Status and Interrupt Mask
registers associated with each measurement channels are
detailed in the Table 27 and in the full register map in the
Register Tables section.
interrupt has cleared. Interrupt status register bits are sticky.
Whenever an interrupt status bit is set, indicating an
out-of-limit condition, it remains set even if the event that
caused it has gone away (until read).
The only way to clear the interrupt status bit is to read the
interrupt status register after the event has gone away.
Interrupt status mask registers allow individual interrupt
sources to be masked from causing an SMBALERT on the
Table 27. INTERRUPT STATUS AND INTERRUPT MASK REGISTER ADDRESS AND BIT ASSIGNMENTS
Interrupt
Status
Register
Interrupt
Mask
Register
0x41
0x74
OOL
R2T
0x42
0x75
D2 FAULT
D1 FAULT
0x43
0x82
OOL
RES
0x81
0x83
VTT
IMON
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
LT
R1T
FAN4/THERM
FAN3
RES
PECI3
SMBALERT Interrupt Behavior
HIGH LIMIT
TEMPERATURE
CLEARED ON READ
(TEMP BELOW LIMIT)
Bit 0
+5 VIN
VCC
VCCP
+2.5 VIN/THERM
FAN2
FAN1
OOL
+12 VIN
RES
OVT
COM
M
DATA
PECI0
PECI2
PECI1
RES
RES
RES
Masking Interrupt Sources
The interrupt mask registers allow individual interrupt
sources to be masked out to prevent SMBALERT interrupts.
Note that masking an interrupt source prevents only the
SMBALERT output from being asserted; the appropriate
status bit is set normally (see Figure 31). Full details of the
status and mask registers associated with each measurement
channel are detailed in Table 27 and Table 44.
TEMP BACK IN LIMIT
SMBALERT
Bit 1
4. Mask the interrupt source by setting the
appropriate mask bit in the interrupt mask registers
(0x74, 0x75, 0x82, and 0x83).
5. Take the appropriate action for a given interrupt
source.
6. Exit the interrupt handler.
7. Periodically poll the status registers. If the
interrupt status bit has cleared, reset the
corresponding interrupt mask bit to 0. This causes
the SMBALERT output and status bits to behave
as shown in Figure 31.
The ADT7490 can be polled for status, or an SMBALERT
interrupt can be generated for out-of-limit conditions. It is
important to note how the SMBALERT output and status
bits behave when writing interrupt handler software.
“STICKY”
STATUS BIT
Bit 2
(STATUS BIT STAYS SET)
Figure 30. SMBALERT and Status Bit Behavior
Figure 30 shows how the SMBALERT output and sticky
status bits behave. Once a limit is exceeded, the
corresponding status bit is set to 1. The status bit remains set
until the error condition subsides and the status register is
read. The status bits are referred to as sticky, because they
remain set until read by software. This ensures that an
out-of-limit event cannot be missed if software is polling the
device periodically.
Note that the SMBALERT output remains low for the
entire duration that a reading is out of limit and until the
status register has been read. This has implications on how
software handles the interrupt.
HIGH LIMIT
TEMPERATURE
“STICKY”
STATUS BIT
Handling SMBALERT Interrupts
SMBALERT
To prevent the system from being tied up servicing
interrupts, it is recommend to handle the SMBALERT
interrupt as follows:
1. Detect the SMBALERT assertion.
2. Enter the interrupt handler.
3. Read the status registers to identify the interrupt
source.
CLEARED ON READ
(TEMP BELOW LIMIT)
TEMP BACK IN LIMIT
(STATUS BIT STAYS SET)
INTERRUPT
MASK BIT SET
INTERRUPT MASK BIT
CLEARED
(SMBALERT RE-ARMED)
Figure 31. How Masking the Interrupt Source Affects
SMBALERT Output
www.onsemi.com
24
ADT7490
Enabling the SMBALERT Interrupt Output
works only if the fan is already running, for example, in
manual mode when the current duty cycle is above 0x00, or
in automatic mode when the temperature is above TMIN.
If the temperature is below TMIN or if the duty cycle in
manual mode is set to 0x00, pulling the THERM low
externally has no effect. See Figure 32 for more information.
The SMBALERT interrupt function is disabled by
default. Pin 10 or Pin 14 can be reconfigured as an
SMBALERT output to signal out-of-limit conditions.
Table 28. CONFIGURING PIN 10 AS SMBALERT
OUTPUT
Register
Bit Setting
Configuration Register 3
(Register 0x78), Bit 0
TMIN
[1] Pin 10 = SMBALERT
[0] Pin 10 = PWM2 (Default)
Assigning THERM Functionality to a Pin
THERM
Pin 14 on the ADT7490 has three possible functions:
SMBALERT, THERM, and TACH4. The user chooses the
required functionality by setting Bit 0 and Bit 1 of
Configuration Register 4 at Address 0x7D.
If THERM is enabled (Bit 1, Configuration Register 3
at Address 0x78),
• Pin 22 becomes THERM.
• If Pin 14 is configured as THERM (Bit 0 and Bit 1 of
Configuration Register 4 at Address 0x7D), THERM is
enabled on this pin.
•
•
THERM ASSERTED TO LOW AS
AN INPUT: FANS DO NOT GO
TO 100% BECAUSE TEMPERATURE
IS BELOW TMIN
Figure 32. Asserting THERM Low as an Input in
Automatic Fan Speed Control Mode
If THERM is not enabled,
Pin 22 becomes a 2.5 VIN measurement input.
If Pin 14 is configured as THERM, THERM is disabled
on this pin.
THERM Timer
The ADT7490 has an internal timer to measure THERM
assertion time. For example, the THERM input can be
connected to the PROCHOT output of a CPU to measure
system performance. The THERM input can also
be connected to the output of a trip point temperature sensor.
The timer is started on the assertion of the ADT7490
THERM input and stopped when THERM is deasserted.
The timer counts THERM times cumulatively, that is, the
timer resumes counting on the next THERM assertion. The
THERM timer continues to accumulate THERM assertion
times until the timer is read (it is cleared on read), or until it
reaches full scale. If the counter reaches full scale, it stops
at that reading until cleared.
The 8-bit THERM timer status register (0x79) is designed
so that Bit 0 is set to 1 on the first THERM assertion. Once
the cumulative THERM assertion time has exceeded
45.52 ms, Bit 1 of the THERM timer is set and Bit 0 now
becomes the LSB of the timer with a resolution of 22.76 ms
(see Figure 33).
Table 29. CONFIGURING PIN 14 IN REGISTER 0x7D
Bit 1
Bit 0
0
0
TACH4
0
1
THERM
1
0
SMBALERT
1
1
Reserved
THERM ASSERTED TO LOW AS
AN INPUT: FANS GO TO 100%
BECAUSE TEMPERATURE IS
ABOVE TMIN AND FANS ARE
ALREADY RUNNING.
Function
THERM as an Input
When THERM is configured as an input, the user can time
assertions on the THERM pin. This can be useful for
connecting to the PROCHOT output of a CPU to gauge
system performance.
The user can also set up the ADT7490 so that the fans run
at 100% when the THERM pin is driven low externally. The
fans run at 100% for the duration of the time that the THERM
pin is pulled low. This is done by setting the BOOST bit
(Bit 2) in Configuration Register 3 (Address 0x78) to 1. This
www.onsemi.com
25
ADT7490
timer value exceeds the THERM timer limit value, the
FAN4 bit (Bit 5) of Status Register 2 is set and an
SMBALERT is generated.
Note that depending on which pins are configured as a
THERM timer, setting the FAN4/THERM bit (Bit 5) of the
Interrupt Mask Register 2 (0x75), or bit 0 of the Interrupt
Mask Register 1 (0x74), masks out SMBALERT; although
the FAN4 bit of Interrupt Status Register 2 is still set if the
THERM timer limit is exceeded.
Figure 34 is a functional block diagram of the THERM
timer, THERM limit, and its associated circuitry. Writing a
value of 0x00 to the THERM Timer Limit register (0x7A)
causes an SMBALERT to be generated on the first THERM
assertion. A THERM timer limit value of 0x01 generates an
SMBALERT once cumulative THERM assertions exceed
45.52 ms.
THERM
THERM
TIMER
(REG. 0x79)
0 0 0 0 0 0 0 1
7 6 5 4 3 2 1 0
THERM ASSERTED
≤22.76 ms
THERM
ACCUMULATE THERM LOW
ASSERTION TIMES
THERM
TIMER
(REG. 0x79)
0 0 0 0 0 0 1 0
7 6 5 4 3 2 1 0
THERM ASSERTED
≥45.52 ms
Configuring the Relevant THERM Behavior
THERM
1. Configure the desired pin as the THERM timer
input. Setting Bit 1 (THERM timer enable) of
Configuration Register 3 (Register 0x78) enables
the THERM timer monitoring functionality. This is
disabled on Pin 14 and Pin 22 by default.
Setting Bit 0 and Bit 1 (Pin 14 Func) of
Configuration Register 4 (Register 0x7D) enables
THERM timer output functionality on Pin 22 (Bit 1
of Configuration Register 3, THERM, must also be
set). Pin 14 can also be used as TACH4.
2. Select the desired fan behavior for THERM timer
events. Assuming the fans are running, setting Bit 2
(BOOST bit) of Configuration Register 3
(Register 0x78) causes all fans to run at 100% duty
cycle whenever THERM is asserted.
This allows fail-safe system cooling. If this bit = 0,
the fans run at their current settings and are not
affected by THERM events. If the fans are not
already running when THERM is asserted, the fans
do not run to full speed.
3. Select whether THERM timer events should
generate SMBALERT interrupts.
Bit 5 of Interrupt Mask Register 2 (0x75) or Bit 0
of Interrupt Mask Register 1 (0x74), depending on
which pins are configured as a THERM timer,
when set, masks out SMBALERTs when the
THERM timer limit value is exceeded. This bit
should be cleared if SMBALERTs based on
THERM events are required.
4. Select a suitable THERM limit value.
This value determines whether an SMBALERT is
generated on the first THERM assertion, or only if
a cumulative THERM assertion time limit is
exceeded. A value of 0x00 causes an SMBALERT
to be generated on the first THERM assertion.
5. Select a THERM monitoring time.
This value specifies how often OS- or BIOS-level
software checks the THERM timer. For example,
ACCUMULATE THERM LOW
ASSERTION TIMES
THERM
TIMER
(REG. 0x79)
0 0 0 0 0 1 0 1
7 6 5 4 3 2 1 0
THERM ASSERTED
≥113.8 ms
(91.04 ms + 22.76 ms)
Figure 33. Understanding the THERM Timer
When using the THERM timer, be aware of the following:
After a THERM timer read (Register 0x79):
• The contents of the timer are cleared on read.
• Bit 5 of Interrupt Status 2 register (0x42) needs to be
cleared (assuming that the THERM timer limit has
been exceeded).
If the THERM timer is read during a THERM assertion,
the following happens:
• The contents of the timer are cleared.
• Bit 0 of the THERM timer is set to 1, because a
THERM assertion is occurring.
• The THERM timer increments from zero.
• If the THERM timer limit (Register 0x7A) = 0x00, the
F4P bit is set.
Generating SMBALERT Interrupts from THERM Timer
Events
The ADT7490 can generate SMBALERTs when a
programmable THERM timer limit has been exceeded. This
allows the system designer to ignore brief, infrequent
THERM assertions while capturing longer THERM timer
events. Register 0x7A is the THERM timer limit register.
This 8-bit register allows a limit from 0 sec (first THERM
assertion) to 5.825 sec to be set before an SMBALERT is
generated. The THERM timer value is compared with the
contents of the THERM timer limit register. If the THERM
www.onsemi.com
26
ADT7490
BIOS can read the THERM timer once an hour to
determine the cumulative THERM assertion time.
If, for example, the total THERM assertion time is
<22.76 ms in Hour 1, >182.08 ms in Hour 2, and
THERM TIMER LIMIT
(REG. 0x7A)
>2.914 sec in Hour 3, this indicates that system
performance is degrading significantly because
THERM is asserting more frequently on an hourly
basis.
2.914 s
1.457 s
728.32 ms
364.16 ms
182.08 ms
91.04 ms
45.52 ms
22.76 ms
2.914 s
1.457 s
728.32 ms
364.16 ms
182.08 ms
91.04 ms
45.52 ms
22.76 ms
0 1 2 3 4 5 6 7
THERM TIMER STATUS
(REG. 0x79)
THERM
7 6 5 4 3 2 1 0
THERM TIMER CLEARED ON READ
COMPARATOR
IN
OUT
LATCH
FAN4 BIT (BIT 5)
INTERRUPT STATUS 2
REGISTER
SMBALERT
RESET
1 = MASK
CLEARED
ON READ
FAN4 BIT (BIT 5)
INTERRUPT MASK REGISTER 2
(REG. 0x75)
Figure 34. Functional Block Diagram of THERM Monitoring Circuitry
THERM temperature limit registers are at Register 0x6A,
Register 0x6B, and Register 0x6C, respectively. Setting
Bits [5:7] of Configuration Register 5 (0x7C) enables the
THERM output feature for the Remote 1, local, and
Remote 2 temperature channels, respectively. Figure 35
shows how the THERM pin asserts low as an output in the
event of a critical overtemperature.
Alternatively, OS- or BIOS-level software can time-stamp
when the system is powered on. If an SMBALERT is
generated due to the THERM timer limit being exceeded,
another time-stamp can be taken. The difference in time can
be calculated for a fixed THERM timer limit time.
For example, if it takes one week for a THERM timer limit
of 2.914 sec to be exceeded, and the next time it takes only
1 hour, this is an indication of a serious degradation in system
performance.
THERM LIMIT
0.255C
THERM LIMIT
Configuring the THERM Pin as an Output
In addition to monitoring THERM as an input, the
ADT7490 can optionally drive THERM low as an output.
When PROCHOT is bidirectional, THERM can be used to
throttle the processor by asserting PROCHOT. The user can
preprogram system-critical thermal limits. If the
temperature exceeds a thermal limit by 0.25°C, THERM
asserts low. If the temperature is still above the thermal limit
on the next monitoring cycle, THERM stays low. THERM
remains asserted low until the temperature is equal to or
below the thermal limit. Because the temperature for that
channel is measured only once for every monitoring cycle,
after THERM asserts, it is guaranteed to remain low for at
least one monitoring cycle.
The THERM pin can be configured to assert low if the
Remote 1 THERM, local THERM, Remote 2 THERM or
PECI temperature limits are exceeded by 0.25°C. The
TEMP
THERM
MONITORING
CYCLE
Figure 35. Asserting THERM as an Output, Based on
Tripping THERM Limits
An alternative method of disabling THERM is to program
the THERM temperature limit to –63°C or less in Offset 64
mode, or −128°C or less in twos complement mode; that is,
for THERM temperature limit values less than –63°C or
–128°C, respectively, THERM is disabled.
www.onsemi.com
27
ADT7490
Enabling and Disabling THERM on Individual
Channels.
VGS < 3.3 V, for direct interfacing to the PWM output pin.
The MOSFET should also have a low on resistance to ensure
that there is not a significant voltage drop across the FET,
which would reduce the voltage applied across the fan and,
therefore, the maximum operating speed of the fan.
Figure 36 shows how to drive a 3-wire fan using PWM
control.
THERM Hysteresis
Setting Bit 0 of Configuration Register 7 (0x11) disables
THERM hysteresis.
If THERM hysteresis is enabled and THERM is disabled
(Bit 2 of Configuration Register 4, 0x7D), the THERM
event is not reflected in the status register and the fans do not
go to full speed. If THERM hysteresis is disabled and
THERM is disabled (Bit 2 of Configuration Register 4,
0x7D) and assuming the appropriate pin is configured as
THERM, the THERM pin asserts low when a THERM event
occurs.
If THERM and THERM hysteresis are both enabled, the
THERM output asserts as expected.
12 V
TACH
10 kW
10 kW
12 V
FAN
TACH
4.7 kW
ADT7490
12 V
1N4148
The THERM pin can be enabled/disabled for individual
or combinations of temperature channels using Bits [7:5] of
Configuration Register 5 (0x7C).
3.3 V
10 kW
Q1
NDT3055L
PWM
Figure 36. Driving a 3-wire Fan Using an N-channel
MOSFET
THERM Operation in Manual Mode
In manual mode, THERM events do not cause fans to go
to full speed, unless Bit 5 of Configuration Register 1
(0x40) is set to 1.
Additionally, Bit 3 of Configuration Register 4 (0x7D)
can be used to select PWM speed on THERM event (100%
or maximum PWM).
Bit 2 in Configuration Register 4 (0x7D) can be set to
disable THERM events from affecting the fans.
Figure 36 uses a 10 kW pullup resistor for the TACH
signal. This assumes that the TACH signal is an
open-collector from the fan. In all cases, the TACH signal
from the fan must be kept below 3.6 V maximum to prevent
damaging the ADT7490.
Figure 37 shows a fan drive circuit using an NPN
transistor such as a general-purpose MMBT2222. While
these devices are inexpensive, they tend to have much lower
current handling capabilities and higher on resistance than
MOSFETs. When choosing a transistor, care should be taken
to ensure that it meets the fan’s current requirements. Ensure
that the base resistor is chosen so that the transistor is
saturated when the fan is powered on.
The ADT7490 uses pulse-width modulation (PWM) to
control fan speed. This relies on varying the duty cycle (or
on/off ratio) of a square wave applied to the fan to vary the
fan speed. The external circuitry required to drive a fan using
PWM control is extremely simple. For 4-wire fans, the
PWM drive may need only a pullup resistor. In many cases,
the 4-wire fan PWM input has a built-in, pullup resistor.
The ADT7490 PWM frequency can be set to a selection
of low frequencies or a single high PWM frequency. The
low frequency options are used for 3-wire fans, while the
high frequency option is usually used with 4-wire fans.
For 3-wire fans, a single N-channel MOSFET is the only
drive device required. The specifications of the MOSFET
depend on the maximum current required by the fan being
driven and the input capacitance of the FET. Because a
10 kW (or greater) resistor must be used as a PWM pullup,
an FET with large input capacitance can cause the PWM
output to become distorted and adversely affect the fan
control range. This is a requirement only when using high
frequency PWM mode.
Typical notebook fans draw a nominal 170 mA, therefore,
SOT devices can be used where board space is a concern. In
desktops, fans typically draw 250 mA to 300 mA each. If
several fans are driven in parallel from a single PWM output
or drive larger server fans, the MOSFET must handle the
higher current requirements. The only other stipulation is
that the MOSFET should have a gate voltage drive,
12 V
TACH
10 kW
10 kW
TACH
4.7 kW
ADT7490
12 V
12 V
FAN
1N4148
Fan Drive Using PWM Control
3.3 V
470 W
PWM
Q1
MMBT2222
Figure 37. Driving a 3-wire Fan Using
an NPN Transistor
Because the fan drive circuitry in 4-wire fans is not
switched on or off, as with previous PWM driven/powered
fans, the internal drive circuit is always on and uses the
PWM input as a signal instead of a power supply. This
enables the internal fan drive circuit to perform better than
3-wire fans, especially for high frequency applications.
Figure 38 shows a typical drive circuit for 4-wire fans.
www.onsemi.com
28
ADT7490
TACH
10 kW
4.7 kW
ADT7490
12 V
3.3 V
10 kW
TYP
12 V, 4-WIRE FAN
10 kW
VCC
TACH
PWM
TACH
TACH4
3.3 V
ADT7490
3.3 V
10 kW
TYP
TACH3
2 kW
3.3 V
PWM
3.3 V
3.3 V
Driving Two Fans from PWM3
Laying Out 3-wire Fans
Figure 41 shows how to lay out a common circuit
arrangement for 3-wire fans.
12 V or 5 V
R1
1N4148
R2
TACH Inputs
Pin 9, Pin 11, Pin 12, and Pin 14 (when configured as
TACH inputs) are high impedance inputs intended for fan
speed measurement.
Signal conditioning in the ADT7490 accommodates the
slow rise and fall times typical of fan tachometer outputs. The
maximum input signal range is 0 V to 3.6 V, even though VCC
is 3.3 V. In the event that these inputs are supplied from fan
outputs that exceed 0 V to 3.6 V, either resistive attenuation
of the fan signal or diode clamping must be included to keep
inputs within an acceptable range.
Figure 42 to Figure 45 show circuits for the most common
fan TACH outputs.
If the fan TACH output has a resistive pullup to VCC, it can
be connected directly to the fan input, as shown in Figure 42.
PWM3
2.2 kW
3.3 V
1N4148
12 V
1 kW
TACH4
3.3 V
10 kW
VCC
12 V
Q1
MMBT3904
10 kW
PWM
Q1
MMBT2222
Figure 41. Planning for 3-wire Fans on a PCB
Bit 4 (SYNC) = 1, synchronizes TACH2, TACH3, and
TACH4 to PWM3.
TACH3
R4
R3
SYNC, Enhanced Acoustics Register 1 (Register 0x62)
ADT7490
3.3 V or 5 V
TACH
TACH measurements for fans are synchronized to
particular PWM channels; for example, TACH1 is
synchronized to PWM1. TACH3 and TACH4 are both
synchronized to PWM3, so PWM3 can drive two fans.
Alternatively, PWM3 can be programmed to synchronize
TACH2, TACH3, and TACH4 to the PWM3 output. This
allows PWM3 to drive two or three fans. In this case, the
drive circuitry looks the same, as shown in Figure 39 and
Figure 40. The SYNC bit in Register 0x62 enables this
function.
Synchronization is not required in high frequency mode
when used with 4-wire fans.
3.3 V
TACH
Figure 40. Interfacing Two Fans in Parallel to the
PWM3 Output Using a Single N-channel MOSFET
Driving up to Three Fans from PWM3
3.3 V
5V
or
12 V
FAN
Q1
NDT3055L
PWM3
The ADT7490 has four TACH inputs available for fan
speed measurement, but only three PWM drive outputs. If a
fourth fan is being used in the system, it should be driven
from the PWM3 output in parallel with the third fan.
Figure 39 shows how to drive two fans in parallel using
low cost NPN transistors. Figure 40 shows the equivalent
circuit using a MOSFET.
Because the MOSFET can handle up to 3.5 A, it is simply
a matter of connecting another fan directly in parallel with
the first. Care should be taken in designing drive circuits
with transistors and FETs to ensure the PWM outputs are not
required to source current, and that they sink less than the
5 mA maximum current specified in the data sheet.
5V
or
12 V
FAN
TACH
10 kW
TYP
Figure 38. Driving a 4-wire Fan
+V
+V
1N4148
12 V
PULLUP
4.7 kW
TYP
Q2
MMBT2222
Q3
MMBT2222
ADT7490
TACH
OUTPUT
TACH
Figure 39. Interfacing Two Fans in Parallel to the
PWM3 Output Using Low Cost NPN Transistors
FAN SPEED
COUNTER
Figure 42. Fan with TACH Pullup to VCC
www.onsemi.com
29
ADT7490
If the fan output has a resistive pullup to 12 V, or other
voltage greater than 3.6 V, the fan output can be clamped
with a Zener diode, as shown in Figure 43. The Zener diode
voltage should be chosen so that it is greater than VIH of the
TACH input but less than 3.6 V, allowing for the voltage
tolerance of the Zener. A value of between 3.0 V and 3.6 V
is suitable.
12 V
The fan counter does not count the fan TACH output
pulses directly because the fan speed could be less than
1,000 RPM, and it takes several seconds to accumulate a
reasonably large and accurate count. Instead, the period of
the fan revolution is measured by gating an on-chip 90 kHz
oscillator into the input of a 16-bit counter for N periods of
the fan TACH output (see Figure 46), so the accumulated
count is actually proportional to the fan tachometer period
and inversely proportional to the fan speed.
N, the number of pulses counted, is determined by the
settings of the TACH pulses per revolution register (0x7B).
This register contains two bits for each fan, allowing one,
two (default), three, or four TACH pulses to be counted.
VCC
PULLUP
4.7 kW
TYP
TACH
OUTPUT
ADT7490
TACH
ZD1*
FAN SPEED
COUNTER
CLOCK
*CHOOSE ZD1 VOLTAGE APPROXIMATELY 0.8 × VCC
Figure 43. Fan with Strong TACH Pullup to > 3.6 V,
(for Example, 12 V) Clamped with Zener Diode
PWM
If the fan has a strong pullup (less than 1 kW) to 12 V or
a totem-pole output, a series resistor can be added to limit the
Zener current, as shown in Figure 44.
FAN
5 V or12 V
TACH
1
2
3
VCC
4
Figure 46. Fan Speed Measurement
PULLUP
TYP < 1 kW
ADT7490
R1
10 kW
TACH
TACH
OUTPUT
ZD1*
ZENER
Fan Speed Measurement Registers
FAN SPEED
COUNTER
The fan tachometer registers are 16-bit values consisting
of a 2-byte read from the ADT7490.
OR TOTEM-POLE
Table 30. FAN TACHOMETER REGISTERS
Register
*CHOOSE ZD1 VOLTAGE APPROXIMATELY 0.8 × VCC
Figure 44. Fan with Strong TACH. Pullup to > VCC
or Totem-Pole Output, Clamped with
Zener Diode and Resistor
Alternatively, a resistive attenuator can be used, as shown
in Figure 45. R1 and R2 should be chosen such that
2 V t V PULLUP R2ńǒR PULLUP ) R1 ) R2Ǔ t 3.6 V (eq. 6)
The fan inputs have an input resistance of nominally
160 kW to ground, which should be taken into account when
calculating resistor values.
With a pullup voltage of 12 V and pullup resistor less than
1 kW, suitable values for R1 and R2 are 100 kW and 40 kW,
respectively. This gives a high input voltage of 3.42 V.
12 V
< 1 kW
TACH
OUTPUT
0x00
0x29
TACH1 High Byte
0x00
0x2A
TACH2 Low Byte
0x00
0x2B
TACH2 High Byte
0x00
0x2C
TACH3 Low Byte
0x00
0x2D
TACH3 High Byte
0x00
0x2E
TACH4 Low Byte
0x00
0x2F
TACH4 High Byte
0x00
The measurement of fan speeds involves a 2-register read
for each measurement. The low byte should be read first.
This causes the high byte to be frozen until both high and
low byte registers have been read, preventing erroneous
TACH readings. The fan tachometer reading registers report
back the number of 11.11 ms period clocks (90 kHz
oscillator) gated to the fan speed counter, from the rising
edge of the first fan TACH pulse to the rising edge of the
third fan TACH pulse (assuming two pulses per revolution
are being counted).
Because the device is essentially measuring the fan TACH
period, the higher the count value, the slower the fan is
actually running. A 16-bit fan tachometer reading of
ADT7490
TACH
Default
TACH1 Low Byte
Reading Fan Speed from the ADT7490
VCC
R1
100 kW
Description
0x28
FAN SPEED
COUNTER
R2
40 kW
Figure 45. Fan with Strong TACH. Pullup to > VCC or
Totem-Pole Output, Attenuated with R1/R2
www.onsemi.com
30
ADT7490
Fan Pulses per Revolution
0xFFFF indicates that either the fan has stalled or is running
very slowly (<100 RPM).
Different fan models can output either one, two, three, or
four TACH pulses per revolution. Once the number of fan
TACH pulses has been determined, it can be programmed
into the TACH pulses per revolution register (0x7B) for each
fan. Alternatively, this register can be used to determine the
number or pulses per revolution output by a given fan. By
plotting fan speed measurements at 100% speed with
different pulses per revolution setting, the smoothest graph
with the lowest ripple determines the correct pulses per
revolution value.
High Limit > Comparison Performed
Because the actual fan TACH period is being measured,
falling below a fan TACH limit by 1 sets the appropriate
status bit and can be used to generate an SMBALERT.
Fan TACH Limit Registers
The fan TACH limit registers are 16-bit values consisting
of two bytes.
Table 31. FAN TACH LIMIT REGISTERS
Register
Description
TACH Pulses per Revolution Register
Default
0x54
TACH1 Minimum Low Byte
0xFF
0x55
TACH1 Minimum High Byte
0xFF
0x56
TACH2 Minimum Low Byte
0xFF
0x57
TACH2 Minimum High Byte
0xFF
0x58
TACH3 Minimum Low Byte
0xFF
0x59
TACH3 Minimum High Byte
0xFF
0x5A
TACH4 Minimum Low Byte
0xFF
0x5B
TACH4 Minimum High Byte
0xFF
Bits [1:0], FAN1 default = 2 pulses per revolution
Bits [3:2], FAN2 default = 2 pulses per revolution
Bits [5:4], FAN3 default = 2 pulses per revolution
Bits [7:6], FAN4 default = 2 pulses per revolution
00 = 1 pulse per revolution
01 = 2 pulses per revolution
10 = 3 pulses per revolution
11 = 4 pulses per revolution
Fan Spin-up
The ADT7490 has a unique fan spin-up function. It spins
the fan at 100% PWM duty cycle until two TACH pulses are
detected on the TACH input. When two TACH pulses have
been detected, the PWM duty cycle goes to the expected
running value, for example, 33%. The advantage of this is
that fans have different spin-up characteristics and take
different times to overcome inertia. The ADT7490 runs the
fans just fast enough to overcome inertia and is quieter on
spin-up than fans programmed to spin up for a given spin-up
time.
Fan Speed Measurement Rate
The fan TACH readings are normally updated once
every second.
When set, the FAST bit (Bit 3) of Configuration Register 3
(0x78), updates the fan TACH readings every 250 ms.
DC Bits
If any of the fans are not being driven by a PWM channel
but are powered directly from 5.0 V or 12 V, their associated
dc bit in Configuration Register 3 should be set. This allows
TACH readings to be taken on a continuous basis for fans
connected directly to a dc source. For 4-wire fans, once high
frequency mode is enabled, the dc bits do not need to be set
because this is automatically done internally.
Fan Startup Timeout
To prevent the generation of false interrupts as a fan spins
up, because the fan is below running speed, the ADT7490
includes a fan startup timeout function. During this time, the
ADT7490 looks for two TACH pulses. If two TACH pulses
are not detected, an interrupt is generated.
Fan startup timeout can be disabled by setting Bit 3
(FSPDIS) of Configuration Register 7 (0x11).
Calculating Fan Speed
Assuming a fan with a two pulses per revolution, and with
the ADT7490 programmed to measure two pulses per
revolution, fan speed is calculated by
Fan Speed (RPM) = (90,000 × 60)/Fan TACH Reading
where Fan TACH Reading is the 16-bit fan tachometer
reading.
Table 32. PWM1, PWM2, PWM3 CONFIGURATION
(REG. 0x5C, REG. 0x5D, REG. 0x5E)
Example
Bit
Mnemonic
Description
[2:0]
SPIN
These Bits Control the Startup Timeout for PWM1 (0x5C),
PWM2 (0x5D), PWM3 (0x5E).
000 = No Startup Timeout
001 = 100 ms
010 = 250 ms (Default)
011 = 400 ms
100 = 667 ms
101 = 1 s
110 = 2 s
111 = 4 s
TACH1 High Byte (Register 0x29) = 0x17
TACH1 Low Byte (Register 0x28) = 0xFF
What is Fan 1 speed in RPM?
Fan 1 TACH Reading = 0x17FF = 6143 (decimal)
RPM = (f × 60)/Fan 1 TACH Reading
RPM = (90,000 × 60)/6143
Fan Speed = 879 RPM
www.onsemi.com
31
ADT7490
Disabling Fan Startup Timeout
Fan Speed Control
Although a fan startup makes fan spin-ups much quieter
than fixed-time spin-ups, the option exists to use fixed
spin-up times. Setting Bit 3 (FSPDIS) to 1 in Configuration
Register 7 (Register 0x11) disables the spin-up for two
TACH pulses. Instead, the fan spins up for the fixed time as
selected in Register 0x5C to Register 0x5E.
The ADT7490 controls fan speed using automatic and
manual modes.
In automatic fan speed control mode, fan speed is
automatically varied with temperature and without CPU
intervention, once initial parameters are set up. The
advantage is that, if the system hangs, the user is guaranteed
that the system is protected from overheating.
In manual fan speed control mode, the ADT7490 allows
the duty cycle of any PWM output to be manually adjusted.
This can be useful if the user wants to change fan speed in
software or adjust PWM duty cycle output for test purposes.
Bits [7:5] of Register 0x5C to Register 0x5E (PWM
Configuration) control the behavior of each PWM output.
PWM Logic State
The PWM outputs can be programmed high for 100%
duty cycle (non-inverted) or low for 100% duty cycle
(inverted).
Table 33. PWM1 CONFIGURATION (REG. 0x5C)
Bit
Mnemonic
[4]
INV
Description
Table 37. PWM CONFIGURATION REGISTERS
(REG. 0x5C TO REG. 0x5E)
0 = Logic High for 100% PWM Duty
Cycle (Non-inverted)
1 = Logic Low for 100% PWM Duty
Cycle (Inverted)
Table 34. PWM2 CONFIGURATION (REG. 0x5D)
Bit
Mnemonic
[4]
INV
Mnemonic
[4]
INV
0 = Logic High for 100% PWM Duty
Cycle
1 = Logic Low for 100% PWM Duty
Cycle
Description
Value (decimal) = PWMMIN/0.39%
0 = Logic High for 100% PWM Duty
Cycle (Non-inverted)
1 = Logic Low for 100% PWM Duty
Cycle (Inverted)
Example 1
For a PWM duty cycle of 50%,
Value (decimal) = 50%/0.39% = 128 (decimal)
Value = 128 (decimal) or 0x80 (hexadecimal)
Example 2
For a PWM duty cycle of 33%,
Value (decimal) = 33%/0.39% = 85 (decimal)
Value = 85 (decimal) or 0x54 (hexadecimal)
Table 36. PWM1, PWM2, PWM3 FREQUENCY
REGISTERS (REG. 0x5F TO 0x61)
Mnemonic
FREQ
Description
111 = Manual Mode
The PWM current duty cycle registers are 8-bit registers
that allow the PWM duty cycle for each output to be set
anywhere from 0% to 100% in steps of 0.39%. The value to
be programmed into the PWMMIN register is given by
The PWM drive frequency can be adjusted for the
application. Register 0x5F to Register 0x61 configure the
PWM frequency for PWM1 to PWM3, respectively.
Bit
BHVR
Programming the PWM Current Duty Cycle Registers
Low Frequency Mode PWM Drive Frequency
[2:0]
Mnemonic
Once under manual control, each PWM output can be
manually updated by writing to Register 0x30 to
Register 0x32 (PWMx current duty cycle registers).
Description
Table 35. PWM3 CONFIGURATION (REG. 0x5E)
Bit
Bit
[7:5]
Table 38. PWM DUTY CYCLE REGISTERS
Description
000 = 11.0 Hz
001 = 14.7 Hz
010 = 22.1 Hz
011 = 29.4 Hz
100 = 35.3 Hz (Default)
101 = 44.1 Hz
110 = 58.8 Hz
111 = 88.2 Hz
Register
Description
Default
0x30
PWM1 Current Duty Cycle
0xFF (100%)
0x31
PWM2 Current Duty Cycle
0xFF (100%)
0x32
PWM3 Current Duty Cycle
0xFF (100%)
By reading the PWMx current duty cycle registers, the
user can keep track of the current duty cycle on each PWM
output, even when the fans are running in automatic fan
speed control mode or acoustic enhancement mode.
However, there is a short delay in updating the PWMx
current duty cycle registers and corresponding duty cycle
outputs due to the devices internal round−robin sequence.
For the successful update of the PWMx current duty cycle
registers and outputs in manual mode, a short delay should
High Frequency Mode PWM Drive
Setting Bit 3 of Register 0x5F, Register 0x60, and
Register 0x61 enables high frequency mode for Fan 1,
Fan 2, and Fan 3, respectively.
In high frequency mode, the PWM drive frequency is
always 22.5 kHz. When high frequency mode is enabled, the
dc bits are automatically asserted internally and do not need
to be changed.
www.onsemi.com
32
ADT7490
THERM Operation in Manual Mode
be observed after writing to the PWMx duty cycle registers
before reading it.
In manual mode, if the temperature increases above the
programmed THERM temperature limit, the fans
automatically speed up to maximum PWM or 100% PWM,
whichever way the appropriate fan channel is configured.
Programming TRANGE
TRANGE defines the distance between TMIN and 100%
PWM. For the ADT7467, ADT7468, and ADT7473,
TRANGE is effectively a slope. For the ADT7475, ADT7476,
and ADT7490, TRANGE is no longer a slope but defines the
temperature region where the PWM output linearly ramps
from PWMMIN to 100% PWM.
Automatic Fan Control Overview
The ADT7490 can automatically control the speed of fans
based on the measured temperature. This is done
independently of CPU intervention once the initial
parameters are set up.
The ADT7490 has a local temperature sensor and two
remote temperature channels that can be connected to a CPU
on-chip thermal diode (available on Intel® Pentium® class
and other CPUs). These three temperature channels can be
used as the basis for automatic fan speed control to drive fans
using pulse-width modulation (PWM).
Automatic fan speed control reduces acoustic noise by
optimizing fan speed according to accurately measured
temperature. Reducing fan speed can also decrease system
current consumption. The automatic fan speed control mode
is very flexible due to the number of programmable
parameters, including TMIN and TRANGE. The TMIN and
TRANGE values for a temperature channel and, therefore, for
a given fan are critical, because they define the thermal
characteristics of the system. The thermal validation of the
system is one of the most important steps in the design
process, so these values should be selected carefully.
Figure 48 gives a top-level overview of the automatic fan
control circuitry on the ADT7490. From a systems-level
perspective, up to three system temperatures can be
monitored and used to control three PWM outputs. The three
PWM outputs can be used to control up to four fans. The
ADT7490 allows the speed of four fans to be monitored.
Each temperature channel has a thermal calibration block,
allowing the designer to individually configure the thermal
characteristics of each temperature channel. For example,
users can decide to run the CPU fan when CPU temperature
increases above 60°C and a chassis fan when the local
temperature increases above 45°C.
At this stage, the designer has not assigned these thermal
calibration settings to a particular fan drive (PWM) channel.
The right side of Figure 48 shows controls that are
fan-specific. The designer has individual control over
parameters such as minimum PWM duty cycle, fan speed
failure thresholds, and even ramp control of the PWM
outputs. Automatic fan control ultimately allows graceful
fan speed changes that are less perceptible to the system user.
PWM = 100%
PWMMAX
PWMMIN
TRANGE
PWM = 0%
TMIN
Figure 47. TRANGE
Programming the Automatic Fan Speed Control Loop
To more efficiently understand the automatic fan speed
control loop, using the ADT7490 evaluation board and
software while reading this section is recommended.
This section provides the system designer with an
understanding of the automatic fan control loop, and
provides step-by-step guidance on effectively evaluating
and selecting critical system parameters. To optimize the
system characteristics, the designer needs to give some
thought to system configuration, including the number of
fans, where they are located, and what temperatures are
being measured in the particular system.
The mechanical or thermal engineer who is tasked with
the system thermal characterization should also be involved
at the beginning of the system development process.
Manual Fan Control Overview
In unusual circumstances, it can be necessary to manually
control the speed of the fans. Because the ADT7490 has an
SMBus interface, a system can read back all necessary
voltage, fan speed, and temperature information, and use
this information to control the speed of the fans by writing
to the current PWM duty cycle register (0x30, 0x31, and
0x32) of the appropriate fan. Bits [7:5] of the PWMx
configuration registers (0x5C, 0x5D, and 0x5E) are used to
set fans up for manual control.
www.onsemi.com
33
ADT7490
THERMAL CALIBRATION
PWM
MIN
100%
S
REMOTE1 =
AMBIENT
TEMP
TMIN
TRANGE
0%
PWM
MIN
THERMAL CALIBRATION
100%
MUX
LOCAL =
VRM TEMP
TMIN
TRANGE
S
0%
PWM
MIN
THERMAL CALIBRATION
100%
S
REMOTE2 =
GPU TEMP
TMIN
TRANGE
PWM
CONFIG
PWM
GENERATOR
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
TACHOMETER 1
MEASUREMENT
PWM
CONFIG
PWM
GENERATOR
TACH1
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
TACHOMETER 2
MEASUREMENT
PWM
CONFIG
PWM
GENERATOR
PWM2
TACH2
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
TACHOMETER 3
AND 4
MEASUREMENT
0%
PWM1
PWM3
TACH3
THERMAL CALIBRATION
100%
PECI =
CPU TEMP
TMIN
TRANGE
0%
Figure 48. Automatic Fan Control Block Diagram
• Is the CPU fan to be controlled using the ADT7490, or
Step 1: Hardware Configuration
During system design, the motherboard sensing and
control capabilities should be addressed early in the design
stages. Decisions about how these capabilities are used
should involve the system thermal/mechanical engineer.
Ask the following questions:
• What ADT7490 functionality is used?
• PWM2 or SMBALERT?
• TACH4 fan speed measurement or overtemperature
THERM function?
• 2.5 VIN voltage monitoring or overtemperature
THERM function?
will the CPU fan run at full speed 100% of the time?
If run at 100%, it frees up a PWM output, but the system
is louder.
• Where is the ADT7490 going to be physically located
in the system?
This influences the assignment of the temperature
measurement channels to particular system thermal zones.
For example, locating the ADT7490 close to the VRM
controller circuitry allows the VRM temperature to be
monitored using the local temperature channel.
The ADT7490 offers multifunctional pins that can be
reconfigured to suit different system requirements and
physical layouts. These multifunction pins are software
programmable.
• How many fans are supported in the system, three or
four? This influences the choice of whether to use the
TACH4 pin or to reconfigure it for the THERM
function.
Step 2: Configuring the Muxtiplexer
After the system hardware configuration is determined,
the fans can be assigned to particular temperature channels.
Not only can fans be assigned to individual channels, but the
behavior of the fans is also configurable. For example, fans
can be run under automatic fan control, can be run manually
(under software control), or can be run at the fastest speed
calculated by multiple temperature channels. The mux is the
www.onsemi.com
34
ADT7490
100 = PWMx runs at 100% duty cycle
110 = PWMx runs at 100% duty cycle
bridge between temperature measurement channels and the
three PWM outputs.
Bits [7:5] (BHVR) of Register 0x5C, Register 0x5D, and
Register 0x5E (PWM configuration registers) control the
behavior of the fans connected to the PWM1, PWM2, and
PWM3 outputs, respectively. The values selected for these
bits determine how the multiplexer connects a temperature
measurement channel to a PWM output.
Step 3: TMIN Settings for Thermal Calibration Channels
TMIN is the temperature at which the fans start to turn on
under automatic fan control. The speed at which the fan runs
at TMIN is programmed later. The TMIN values chosen are
temperature channel specific, for example, 25°C for
ambient channel, 30°C for VRM temperature, and 40°C for
processor temperature.
TMIN is an 8-bit value, either twos complement or Offset
64, that can be programmed in 1°C increments. A TMIN
register is associated with each temperature measurement
channel: Remote 1, local, Remote 2 and PECI temperature.
When the TMIN value is exceeded, the fan turns on and runs
at the minimum PWM duty cycle. The fan turns off once the
temperature has dropped below TMIN − THYST.
To overcome fan inertia, the fan is spun up until two valid
TACH rising edges are counted. See the Fan Startup
Timeout section for more details. In some cases, primarily
for psycho-acoustic reasons, it is desirable that the fan never
switch off below TMIN. When set, Bits [7:5] of Enhanced
Acoustics Register 1 (0x62) keep the fans running at the
PWM minimum duty cycle if the temperature should fall
below TMIN.
Automatic Fan Control Multiplexer Options
Bits [7:5] (BHVR), Register 0x5C, Register 0x5D, and
Register 0x5E, with the ALT bit (Bit 3) cleared to 0.
000 = Remote 1 temperature controls PWMx
001 = Local temperature controls PWMx
010 = Remote 2 temperature controls PWMx
101 = Fastest speed calculated by local and Remote 2
temperature controls PWMx
110 = Fastest speed calculated by all three temperature
channels controls PWMx
The fastest speed calculated options pertain to controlling
one PWM output based on multiple temperature channels.
The thermal characteristics of the three temperature zones
can be set to drive a single fan. An example is the fan turning
on when the Remote 1 temperature exceeds 60°C or if
the local temperature exceeds 45°C.
Setting the ALT bit in Register 0x5C, Register 0x5D, and
Register 0x5E gives alternative behavior settings for
Bits [7:5] of the PWM configuration registers.
Bits [7:5] (BHVR), Register 0x5C, Register 0x5D, and
Register 0x5E, with the ALT bit (Bit 3) set to 1.
000 = PECI0 reading controls PWMx
001 = PECI1 reading controls PWMx
010 = PECI2 reading controls PWMx
011 = PECI3 reading controls PWMx
101 = Fastest speed calculated by all four PECI
readings controls PWMx
111 = Fastest speed calculated by all thermal zones
(Local, Rem1, Rem2 and PECI) controls PWMx
Table 39. TMIN REGISTERS
Register
Description
Default
0x67
Remote 1 Temperature TMIN
0x5A (90°C)
0x68
Local Temperature TMIN
0x5A (90°C)
0x69
Remote 2 Temperature TMIN
0x5A (90°C)
0x3B
PECI TMIN
0xE0 (−32°C)
Enhanced Acoustics Register 1 (Register 0x62)
Bit 7 (MIN3) = 0, PWM3 is off (0% PWM duty cycle) when
the temperature is below TMIN – THYST.
Bit 7 (MIN3) = 1, PWM3 runs at PWM3 minimum duty
cycle below TMIN – THYST.
Bit 6 (MIN2) = 0, PWM2 is off (0% PWM duty cycle) when
the temperature is below TMIN – THYST.
Bit 6 (MIN2) = 1, PWM2 runs at PWM2 minimum duty
cycle below TMIN – THYST.
Bit 5 (MIN1) = 0, PWM1 is off (0% PWM duty cycle) when
the temperature is below TMIN – THYST.
Bit 5 (MIN1) = 1, PWM1 runs at PWM1 minimum duty
cycle below TMIN – THYST.
Other Mux Options
Bits [7:5] (BHVR), Register 0x5C, Register 0x5D, and
Register 0x5E, with the ALT bit (Bit 3) cleared to 0.
011 = PWMx runs full speed
100 = PWMx disabled (default)
111 = Manual mode. PWMx is running under software
control. In this mode, PWM duty cycle registers
(Register 0x30 to Register 0x32) are writable and
control the PWM outputs.
Bits [7:5] (BHVR), Register 0x5C, Register 0x5D, and
Register 0x5E, with the ALT bit (Bit 3) set to 1.
www.onsemi.com
35
ADT7490
PWM DUTY CYCLE
100%
0%
TMIN
THERMAL CALIBRATION
PWM
MIN
100%
PWM
GENERATOR
S
TMIN
REMOTE2 =
CPU TEMP
TRANGE
0%
PWM
MIN
THERMAL CALIBRATION
100%
TMIN
LOCAL =
VRM TEMP
TRANGE
0%
PWM
MIN
THERMAL CALIBRATION
100%
S
TMIN
REMOTE1 =
AMBIENT TEMP
TRANGE
PWM
CONFIG
CPU FAN SINK
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
TACHOMETER2
MEASUREMENT
PWM
CONFIG
PWM
GENERATOR
PWM2
TACH2
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
Figure 49. Understanding the TMIN Parameter
FRONT CHASSIS
PWM3
TACH3
REAR CHASSIS
More than one PWM output can be controlled from a
single temperature measurement channel. For example,
Remote 1 temperature can control PWM1 and PWM2
outputs. If two different fans are used on PWM1 and PWM2,
the fan characteristics can be set up differently. As a result,
Fan 1 driven by PWM1 can have a different PWMMIN value
than that of Fan 2 connected to PWM2. Figure 51 illustrates
this as PWM1MIN (front fan) turned on at a minimum duty
cycle of 20%, while PWM2MIN (rear fan) is turned on at a
minimum of 40% duty cycle. Note that both fans turn on at
exactly the same temperature, defined by TMIN.
PWMMIN is the minimum PWM duty cycle at which each
fan in the system runs. It is also the start speed for each fan
under automatic fan control once the temperature rises
above TMIN. For maximum system acoustic benefit,
PWMMIN should be as low as possible. Depending on the
fan used, the PWMMIN setting is usually in the 20% to 33%
duty cycle range. This value can be found through fan
validation.
100%
PWMMIN
0%
TMIN
PWM1
TACH1
TACHOMETER3
AND 4
MEASUREMENT
0%
Step 4: PWMMIN for Each PWM (Fan) Output
PWM DUTY CYCLE
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
TACHOMETER1
MEASUREMENT
PWM
GENERATOR
S
MUX
PWM
CONFIG
TEMPERATURE
Figure 50. PWMMIN Determines Minimum
PWM Duty Cycle
www.onsemi.com
36
ADT7490
as low as possible, but should be capable of maintaining the
processor temperature limit at an acceptable level. If the
THERM temperature limit is exceeded, the fans are still
boosted to 100% for fail-safe cooling.
There is a PWMMAX limit for each fan channel. The
default value of this register is 0xFF and has no effect unless
it is programmed.
PWM DUTY CYCLE
100%
PWM2
PWM1
PWM2MIN
PWM1MIN
0%
TMIN
PWM DUTY CYCLE
100%
TEMPERATURE
Figure 51. Operating Two Different Fans from
a Single Temperature Channel
Programming the PWMMIN Registers
The PWMMIN registers are 8-bit registers that allow the
minimum PWM duty cycle for each output to be configured
anywhere from 0% to 100%. This allows the minimum
PWM duty cycle to be set in steps of 0.39%.
The value to be programmed into the PWMMIN register is
given by:
TMIN
TEMPERATURE
Figure 52. PWMMAX Determines Maximum PWM Duty
Cycle Below the THERM Temperature Limit
Programming the PWMMAX Registers
The PWMMAX registers are 8-bit registers that allow the
maximum PWM duty cycle for each output to be configured
anywhere from 0% to 100%. This allows the maximum
PWM duty cycle to be set in steps of 0.39%.
The value to be programmed into the PWMMAX register
is given by:
Example 1
For a minimum PWM duty cycle of 50%,
Value (decimal) = 50%/0.39% = 128 (decimal)
Value = 128 (decimal) or 0x80 (hexadecimal)
Example 2
For a minimum PWM duty cycle of 33%,
Value (decimal) = 33%/0.39% = 85 (decimal)
Value = 85 (decimal) or 0x54 (hexadecimal)
Value (decimal) = PWMMAX/0.39%
Example 1
For a maximum PWM duty cycle of 50%,
Value (decimal) – 50%/0.39% = 128 (decimal)
Value = 128 (decimal) or 0x80 (hexadecimal)
Table 40. PWMMIN REGISTERS
Description
Default
0x64
PWM1 Minimum Duty Cycle
0x80 (50%)
0x65
PWM2 Minimum Duty Cycle
0x80 (50%)
0x66
PWM3 Minimum Duty Cycle
0x80 (50%)
Example 2
For a minimum PWM duty cycle of 75%,
Value (decimal) = 75%/0.39% = 85 (decimal)
Value = 192 (decimal) or 0xC0 (hexadecimal)
Note on Fan Speed and PWM Duty Cycle
The PWM duty cycle does not directly correlate to fan
speed in RPM. Running a fan at 33% PWM duty cycle does
not equate to running the fan at 33% speed. Driving a fan at
33% PWM duty cycle actually runs the fan at closer to 50%
of its full speed. This is because fan speed in %RPM
generally relates to the square root of PWM duty cycle.
Given a PWM square wave as the drive signal, fan speed in
RPM approximates to
% fanspeed + ǸPWM Duty Cycle
PWMMIN
0%
Value (decimal) = PWMMIN/0.39%
Register
PWMMAX
10
Table 41. PWMMAX REGISTERS
Register
Description
Default
0x38
PWM1 Maximum Duty Cycle
0xFF (100%)
0x39
PWM2 Maximum Duty Cycle
0xFF (100%)
0x3A
PWM3 Maximum Duty Cycle
0xFF (100%)
Step 6: TRANGE for Temperature Channels
TRANGE is the range of temperature over which automatic
fan control occurs once the programmed TMIN temperature
has been exceeded. TRANGE is the temperature range between
PWMMIN and 100% PWM where the fan speed changes
linearly. Otherwise stated, it is the line drawn between the
TMIN/PWMMIN and the (TMIN + TRANGE)/100% PWM
intersection points.
(eq. 7)
Step 5: PWMMAX for PWM (Fan) Outputs
PWMMAX is the maximum duty cycle that each fan in the
system runs at under the automatic fan speed control loop.
For maximum system acoustic benefit, PWMMAX should be
www.onsemi.com
37
ADT7490
TRANGE
PWM DUTY CYCLE
100%
PWM DUTY CYCLE
100%
PWMMIN
10%
0%
0%
TMIN
TMIN−HYST
TEMPERATURE
Figure 53. TRANGE Parameter Affects Cooling Slope
TMIN
The TRANGE is determined by the following procedure:
1. Determine the maximum operating temperature for
that channel (for example, 70°C).
2. Determine experimentally the fan speed (PWM
duty cycle value) that does not exceed the
temperature at the worst-case operating points. For
example, 70°C is reached when the fans are
running at 50% PWM duty cycle.
3. Determine the slope of the required control loop to
meet these requirements.
4. Using the ADT7490 evaluation software,
graphically program and visualize this
functionality. Ask a local Analog Devices
representative for details.
Figure 55. Increasing TRANGE Changes the AFC Slope
PWM DUTY CYCLE
100%
MAX
PWM
10%
0%
TMIN−HYST
TRANGE
Figure 56. Changing PWMMAX Does Not Change the
AFC Slope
As PWMMIN is changed, the automatic fan control slope
changes.
Selecting TRANGE
The TRANGE value can be selected for each temperature
channel: Remote 1, local, Remote 2, and PECI temperature.
Bits [7:4] (TRANGE) of Register 0x5F to Register 0x61 and
Register 0x3C define the TRANGE value for each
temperature channel.
100%
PWM DUTY CYCLE
30°C
40°C
45°C
54°C
Table 42. SELECTING A TRANGE VALUE
50%
Bits [7:4] (Note 1)
33%
0%
30°C
TMIN
Figure 54. Adjusting PWMMIN Changes the Automatic
Fan Control Slope
As TRANGE is changed, the slope changes. As TRANGE
gets smaller, the fans reach 100% speed with a smaller
temperature change.
TRANGE (5C)
0000
2
0001
2.5
0010
3.33
0011
4
0100
5
0101
6.67
0110
8
0111
10
1000
13.33
1001
16
1010
20
1011
26.67
1100
32 (default)
1101
40
1110
53.33
1111
80
1. Register 0x5F configures Remote 1 TRANGE; Register 0x60
configures local TRANGE; Register 0x61 configures Remote 2
TRANGE, Register 0x3C configures PECI TRANGE.
www.onsemi.com
38
ADT7490
Actual Changes in PWM Output
(Advanced Acoustics Settings)
The graphs in Figure 57 assume the fan starts from 0%
PWM duty cycle. Clearly, the minimum PWM duty cycle,
PWMMIN, needs to be factored in to see how the loop
actually performs in the system. Figure 58 shows how
TRANGE is affected when the PWMMIN value is set to 20%.
It can be seen that the fan actually runs at about 45% fan
speed when the temperature exceeds TMIN.
While the automatic fan control algorithm describes the
general response of the PWM output, it is also necessary to
note that the enhanced acoustics registers (0x62, 0x63, and
0x3C) can be used to set/clamp the maximum rate of change
of PWM output for a given temperature zone. This means that
if TRANGE is programmed with an AFC slope that is quite
steep, a relatively small change in temperature could cause a
large change in PWM output and possibly an audible change
in fan speed, which can be noticeable/annoying to end users.
Decreasing the speed of the PWM output changes by
programming the smoothing on the appropriate temperature
channels (Register 0x62 and Register 0x63) changes how
fast the fan speed increases/decreases in the event of a
temperature spike. Slowly the PWM duty cycle increases
until the PWM duty cycle reaches the appropriate duty cycle
as defined by the AFC curve.
Figure 57 shows PWM duty cycle vs. temperature for
each TRANGE setting. Figure 57B shows how each TRANGE
setting affects fan speed vs. temperature. As can be seen
from the graph, the effect on fan speed is nonlinear.
100
PWM DUTY CYCLE (%)
45C
55C
70
6.675C
85C
60
105C
50
13.35C
165C
40
205C
30
26.65C
20
0
325C
405C
53.35C
0
20
40
60
85C
105C
13.35C
165C
40
205C
30
26.65C
20
325C
405C
53.35C
0
20
40
60
80
100
120
805C
2.55C
3.335C
80
45C
55C
70
6.675C
60
85C
105C
50
13.35C
40
165C
205C
30
26.65C
20
325C
405C
10
TEMPERATURE ABOVE TMIN
0
(A)
53.35C
0
3.335C
55C
70
6.675C
105C
50
165C
205C
30
26.65C
20
325C
405C
10
53.35C
0
20
40
60
80
100
120
100
120
805C
TTHERM is the absolute maximum temperature allowed
on a temperature channel. For PECI temperature channels,
the equivalent parameter is TCONTROL. Above this
temperature, a component such as the CPU or VRM may be
operating beyond its safe operating limit. When the
temperature measured exceeds TTHERM, all fans are driven
at 100% PWM duty cycle (full speed) to provide critical
system cooling.
The fans remain running at 100% until the temperature
drops below TTHERM minus hysteresis, where hysteresis is
the number programmed into the hysteresis registers (0x6D
and 0x6E). The default hysteresis value is 4°C.
13.35C
40
80
Step 7: TTHERM for Temperature Channels
85C
60
60
Figure 58. TRANGE and % Fan Speed Slopes with
PWMMIN = 20%
45C
80
40
(B)
2.55C
90
20
TEMPERATURE ABOVE TMIN
25C
100
805C
25C
90
6.675C
50
120
100
55C
60
100
(A)
45C
70
80
TEMPERATURE ABOVE TMIN
FAN SPEED (% OF MAX)
PWM DUTY CYCLE (%)
3.335C
80
10
3.335C
10
FAN SPEED (% OF MAX)
2.55C
90
2.55C
80
0
25C
25C
90
0
100
805C
TEMPERATURE ABOVE TMIN
(B)
Figure 57. TRANGE vs. Actual Fan Speed
(Not PWM Drive) Profile
www.onsemi.com
39
ADT7490
THERM Hysteresis
The TTHERM limit should be considered the maximum
worst-case operating temperature of the system. Because
exceeding any TTHERM limit runs all fans at 100%, it has
very negative acoustic effects. Ultimately, this limit should
be set up as a fail-safe, and one should ensure that it is not
exceeded under normal system operating conditions.
Note that TTHERM limits are non-maskable and affect the
fan speed no matter how automatic fan control settings are
configured. This allows some flexibility, because a TRANGE
value can be selected based on its slope, while a hard limit
(such as 70°C), can be programmed as TMAX (the
temperature at which the fan reaches full speed) by setting
TTHERM to that limit (for example, 70°C).
THERM hysteresis on a particular channel is configured
via the hysteresis settings in the following section (0x6D and
0x6E). For example, setting hysteresis on the Remote 1
channel also sets the hysteresis on Remote 1 THERM.
Hysteresis Registers
Register 0x6D, Remote 1, Local Hysteresis Register
Bits [7:4], Remote 1 Temperature Hysteresis (4°C default)
Bits [3:0], Local Temperature Hysteresis (4°C default)
Register 0x6E, Remote 2, PECI Temperature Hysteresis
Register
Bits [7:4], Remote 2 Temperature Hysteresis (4°C default)
Bits [3:0], PECI Temperature Hysteresis (4°C default)
Table 43. THERM REGISTERS
Register
Description
Because each hysteresis setting is four bits, hysteresis
values are programmable from 1°C to 15°C. It is not
recommended that hysteresis values ever be programmed to
0°C, because this disables hysteresis. In effect, this causes
the fans to cycle (during a THERM event) between normal
speed and 100% speed, or, while operating close to TMIN,
between normal speed and off, creating unsettling acoustic
noise.
Default
0x6A
Remote 1 THERM Limit
0x64 (100°C)
0x6B
Local THERM Limit
0x64 (100°C)
0x6C
Remote 2 THERM Limit
0x64 (100°C)
0x3D
PECI TCONTROL Limit
0x00 (0°C)
TRANGE
PWM DUTY CYCLE
100%
0%
TMIN
TTHERM
THERMAL CALIBRATION
PWM
MIN
100%
S
TMIN
REMOTE2 =
CPU TEMP
TRANGE
0%
PWM
MIN
THERMAL CALIBRATION
100%
S
MUX
TMIN
LOCAL =
VRM TEMP
TRANGE
0%
THERMAL CALIBRATION
PWM
MIN
100%
S
TMIN
TRANGE
PWM
CONFIG
PWM
GENERATOR
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
TACHOMETER1
MEASUREMENT
PWM
CONFIG
PWM
GENERATOR
TACH1
CPU FAN SINK
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
TACHOMETER2
MEASUREMENT
PWM
CONFIG
PWM
GENERATOR
PWM2
TACH2
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
TACHOMETER3
AND 4
MEASUREMENT
0%
PWM1
FRONT CHASSIS
PWM3
TACH3
REMOTE1 =
AMBIENT TEMP
Figure 59. How TTHERM Relates to Automatic Fan Control
www.onsemi.com
40
REAR CHASSIS
ADT7490
Step 8: THYST for Temperature Channels
The THYST setting applies not only to the temperature
hysteresis for fan on/off, but the same setting is used for the
TTHERM hysteresis value, described in the Step 7: TTHERM
for Temperature Channels section. Therefore, programming
Register 0x6D and Register 0x6E sets the hysteresis for
both fan on/off and the THERM function.
In some applications, it is required that fans not turn off
below TMIN, but remain running at PWMMIN. Bits [7:5] of
Enhanced Acoustics Register 1 (0x62) allow the fans to be
turned off or to be kept spinning below TMIN. If the fans are
always on, the THYST value has no effect on the fan when the
temperature drops below TMIN.
THYST is the amount of extra cooling a fan provides after
the temperature measured has dropped back below TMIN
before the fan turns off. The premise for temperature
hysteresis (THYST) is that, without it, the fan would merely
chatter, or cycle on and off regularly, whenever the
temperature is hovering at about the TMIN setting.
The THYST value chosen determines the amount of time
needed for the system to cool down or heat up as the fan is
turning on and off. Values of hysteresis are programmable in
the range of 1°C to 15°C. Larger values of THYST prevent the
fans from chattering on and off. The THYST default value is
set at 4°C.
TRANGE
PWM DUTY CYCLE
100%
0%
TMIN
TTHERM
THERMAL CALIBRATION
PWM
MIN
100%
PWM
GENERATOR
S
TMIN
REMOTE2 =
CPU TEMP
TRANGE
0%
PWM
MIN
THERMAL CALIBRATION
100%
TMIN
LOCAL =
VRM TEMP
TRANGE
0%
PWM
MIN
THERMAL CALIBRATION
100%
S
TMIN
TRANGE
PWM
CONFIG
PWM
CONFIG
PWM
GENERATOR
PWM1
TACH1
CPU FAN SINK
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
TACHOMETER2
MEASUREMENT
TACHOMETER3
AND 4
MEASUREMENT
0%
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
TACHOMETER1
MEASUREMENT
PWM
GENERATOR
S
MUX
PWM
CONFIG
PWM2
TACH2
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
FRONT CHASSIS
PWM3
TACH3
REMOTE1 =
AMBIENT TEMP
REAR CHASSIS
Figure 60. The THYST Value Applies to Fan On/Off Hysteresis and THERM Hysteresis
THERM Hysteresis
Bit 7 (MIN3) = 1, PWM3 runs at PWM3 minimum duty
cycle below TMIN − THYST.
Bit 6 (MIN2) = 0, PWM2 is off (0% PWM duty cycle) when
the temperature is below TMIN − THYST.
Bit 6 (MIN2) = 1, PWM2 runs at PWM2 minimum duty
cycle below TMIN − THYST.
Any hysteresis programmed via Register 0x6D and
Register 0x6E also applies hysteresis on the appropriate
THERM channel.
Enhanced Acoustics Register 1 (Register 0x62)
Bit 7 (MIN3) = 0, PWM3 is off (0% PWM duty cycle) when
temperature is below TMIN − THYST.
www.onsemi.com
41
ADT7490
When Bit 7 of Configuration Register 6 (0x10) = 1, the
preceding ramp rates change to
000 = 52.2 sec
001 = 26.1 sec
010 = 17.4 sec
011 = 10.4 sec
100 = 6.5 sec
101 = 4.4 sec
110 = 2.2 sec
111 = 1.1 sec
Bit 5 (MIN1) = 0, PWM1 is off (0% PWM duty cycle) when
the temperature is below TMIN − THYST.
Bit 5 (MIN1) = 1, PWM1 runs at PWM1 minimum duty
cycle below TMIN − THYST.
Configuration Register 6 (Register 0x10)
Bit 0 (SLOW) = 1, slows the ramp rate for PWM changes
associated with the Remote 1 temperature channel by 4.
Bit 1 (SLOW) = 1, slows the ramp rate for PWM changes
associated with the local temperature channel by 4.
Bit 2 (SLOW) = 1, slows the ramp rate for PWM changes
associated with the Remote 2 temperature channel by 4.
Bit 7 (ExtraSlow) = 1, slows the ramp rate for all fans by a
factor of 39.2%.
Setting the appropriate SLOW Bit 2, Bit 1, or Bit 0 of
Configuration Register 6 (0x10) slows the ramp rate further
by a factor of 4.
Programming the GPIOs
The following sections list the ramp-up times when the
SLOW bit is set for each temperature monitoring channel.
The ADT7490 has two dedicated GPIOs (Pin 5 and
Pin 6).The direction (input or output) and polarity (active
high or active low) of the GPIOs is set in the GPIO
Configuration Register (0x80). Bit 2 and Bit 3 of
Register 0x80 also reflect the state of the GPIO pins when
configured as inputs and assert the GPIO pins when
configured as outputs.
Enhanced Acoustics Register 1 (Register 0x62)
Bits [2:0] ACOU, selects the ramp rate for PWM outputs
associated with the Remote Temperature 1 input.
000 = 37.5 sec
001 = 18.8 sec
010 = 12.5 sec
011 = 7.5 sec
100 = 4.7 sec
101 = 3.1 sec
110 = 1.6 sec
111 = 0.8 sec
XNOR Tree Test Mode
The ADT7490 includes an XNOR tree test mode. This
mode is useful for in-circuit test equipment at board-level
testing. By applying stimulus to the pins included in the
XNOR tree, it is possible to detect opens, or shorts, on the
system board.
The XNOR tree test is invoked by setting Bit 0 (XEN) of
the XNOR Tree Test Enable register (Register 0x6F).
Figure 61 shows the signals that are exercised in the
XNOR tree test mode.
Enhanced Acoustics Register 2 (Register 0x63)
Bits [2:0] ACOU3, selects the ramp rate for PWM outputs
associated with the local temperature channel.
000 = 37.5 sec
001 = 18.8 sec
010 = 12.5 sec
011 = 7.5 sec
100 = 4.7 sec
101 = 3.1 sec
110 = 1.6 sec
111 = 0.8 sec
[6:4] ACOU2, selects the ramp rate for PWM outputs
associated with the Remote Temperature 2 input.
000 = 37.5 sec
001 = 18.8 sec
010 = 12.5 sec
011 = 7.5 sec
100 = 4.7 sec
101 = 3.1 sec
110 = 1.6 sec
111 = 0.8 sec
PWM2
PWM3
TACH1
TACH2
TACH3
TACH4
PWM1/XTO
Figure 61. XNOR Tree Test
www.onsemi.com
42
ADT7490
Register Tables
Table 44. ADT7490 REGISTERS
Default
Lockable
SLOW
Remote
1
0x00
Yes
FSPD
THERM
Hys
0x00
Yes
RES
RES
−
−
−
3
2
1
0
0x80
−
Addr
R/W
Desc
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0x10
R/W
Config.
Reg. 6
Extra
Slow
VCCP
Low
Res
Res
Res
SLOW
Remote
2
SLOW
Local
0x11
R/W
Config.
Reg. 7
RES
RES
RES
TODIS
FSPDIS
Vx1
0x12
R
Extended
Revision
RES
RES
RES
RES
RES
0x1A
R
PECI1
7
6
5
4
0x1B
R
PECI2
7
6
5
4
3
2
1
0
0x80
−
0x1C
R
PECI3
7
6
5
4
3
2
1
0
0x80
−
0x1D
R
IMON
Meas.
9
8
7
6
5
4
3
2
0x00
−
0x1E
R
VTT
Meas.
9
8
7
6
5
4
3
2
0x00
−
0x1F
R
Extended
Resolution
3
IMON
IMON
VTT
VTT
RES
RES
RES
RES
0x00
−
0x20
R
+2.5VIN
Meas.
9
8
7
6
5
4
3
2
0x00
−
0x21
R
VCCP
Meas.
9
8
7
6
5
4
3
2
0x00
−
0x22
R
VCC
Meas.
9
8
7
6
5
4
3
2
0x00
−
0x23
R
+5VIN
Meas.
9
8
7
6
5
4
3
2
0x00
−
0x24
R
+12VIN
Meas.
9
8
7
6
5
4
3
2
0x00
−
0x25
R
Remote 1
Temp.
9
8
7
6
5
4
3
2
0x80
−
0x26
R
Local
Temp.
9
8
7
6
5
4
3
2
0x80
−
0x27
R
Remote 2
Temp.
9
8
7
6
5
4
3
2
0x80
−
0x28
R
TACH1
Low Byte
7
6
5
4
3
2
1
0
0x00
−
0x29
R
TACH1
High Byte
15
14
13
12
11
10
9
8
0x00
−
0x2A
R
TACH2
Low Byte
7
6
5
4
3
2
1
0
0x00
−
0x2B
R
TACH2
High Byte
15
14
13
12
11
10
9
8
0x00
−
0x2C
R
TACH3
Low Byte
7
6
5
4
3
2
1
0
0x00
−
0x2D
R
TACH3
High Byte
15
14
13
12
11
10
9
8
0x00
−
0x2E
R
TACH4
Low Byte
7
6
5
4
3
2
1
0
0x00
−
0x2F
R
TACH4
High Byte
15
14
13
12
11
10
9
8
0x00
−
0x30
R/W
PWM1
Current
Duty
Cycle
7
6
5
4
3
2
1
0
0xFF
−
0x31
R/W
PWM2
Current
Duty
Cycle
7
6
5
4
3
2
1
0
0xFF
−
www.onsemi.com
43
ADT7490
Table 44. ADT7490 REGISTERS (continued)
Addr
R/W
Desc
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Default
Lockable
0x32
R/W
PWM3
Current
Duty
Cycle
7
6
5
4
3
2
1
0
0xFF
−
0x33
R
PECI0
7
6
5
4
3
2
1
0
0x80
−
0x34
R/W
PECI Low
Limit
7
6
5
4
3
2
1
0
0x81
−
0x35
R/W
PECI
High Limit
7
6
5
4
3
2
1
0
0x00
−
0x36
R/W
PECI
Config.
Register 1
RES
RES
RES
RE−
PLACE
DOM0
AVG2
AVG1
AVG0
0x00
Yes
0x38
R/W
Max
PWM1
Duty
Cycle
7
6
5
4
3
2
1
0
0xFF
Yes
0x39
R/W
Max
PWM2
Duty
Cycle
7
6
5
4
3
2
1
0
0xFF
Yes
0x3A
R/W
Max
PWM3
Duty
Cycle
7
6
5
4
3
2
1
0
0xFF
Yes
0x3B
R/W
PECI
TMIN
7
6
5
4
3
2
1
0
0xE0
Yes
0x3C
R/W
PECI
TRANGE/
Enhanced
Acoustics
RANGE
RANGE
RANGE
RANGE
ENP
ACOU
ACOU
ACOU
0xC0
Yes
0x3D
R/W
PECI
TCONTROL
Limit
7
6
5
4
3
2
1
0
0x00
Yes
0x3E
R
Company
ID No.
7
6
5
4
3
2
1
0
0x41
−
0x3F
R
Version
VER3
VER2
VER1
VER0
4−Wire
PECI
REV1
REV0
0x06X
−
0x40
R/W
Config.
Register 1
RES
RES
THERM
in
Manual
PECI
Monitor
Fan
Boost
RDY
LOCK
STRT
0x04
Yes
0x41
R
Interrupt
Status 1
OOL
R2T
LT
R1T
+5VIN
VCC
VCCP
+2.5VIN/
THERM
0x00
−
0x42
R
Interrupt
Status 2
D2
FAULT
D1
FAULT
FAN4/
THERM
FAN3
FAN2
FAN1
OOL
+12VIN
0x00
−
0x43
R
Interrupt
Status 3
OOL
RES
RES
RES
OVT
(THERM
Temp
Limit)
COMM
DATA
PECI0
0x00
−
0x44
R/W
+2.5VIN
Low Limit
7
6
5
4
3
2
1
0
0x00
−
0x45
R/W
+2.5VIN
High Limit
7
6
5
4
3
2
1
0
0xFF
−
0x46
R/W
VCCP
Low Limit
7
6
5
4
3
2
1
0
0x00
−
0x47
R/W
VCCP
High Limit
7
6
5
4
3
2
1
0
0xFF
−
0x48
R/W
VCC
Low Limit
7
6
5
4
3
2
1
0
0x00
−
0x49
R/W
VCC
High Limit
7
6
5
4
3
2
1
0
0xFF
−
0x4A
R/W
+5VIN
Low Limit
7
6
5
4
3
2
1
0
0x00
−
0x4B
R/W
+5VIN
High Limit
7
6
5
4
3
2
1
0
0xFF
−
www.onsemi.com
44
ADT7490
Table 44. ADT7490 REGISTERS (continued)
Addr
R/W
Desc
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Default
Lockable
0x4C
R/W
+12VIN
Low Limit
7
6
5
4
3
2
1
0
0x00
−
0x4D
R/W
+12VIN
High Limit
7
6
5
4
3
2
1
0
0xFF
−
0x4E
R/W
Remote 1
Temp Low
Limit
7
6
5
4
3
2
1
0
0x81
−
0x4F
R/W
Remote 1
Temp
High Limit
7
6
5
4
3
2
1
0
0x7F
−
0x50
R/W
Local
Temp Low
Limit
7
6
5
4
3
2
1
0
0x81
−
0x51
R/W
Local
Temp
High Limit
7
6
5
4
3
2
1
0
0x7F
−
0x52
R/W
Remote 2
Temp Low
Limit
7
6
5
4
3
2
1
0
0x81
−
0x53
R/W
Remote 2
Temp
High Limit
7
6
5
4
3
2
1
0
0x7F
−
0x54
R/W
TACH1
Min Low
Byte
7
6
5
4
3
2
1
0
0xFF
−
0x55
R/W
TACH1
Min High
Byte
15
14
13
12
11
10
9
8
0xFF
−
0x56
R/W
TACH2
Min Low
Byte
7
6
5
4
3
2
1
0
0xFF
−
0x57
R/W
TACH2
Min High
Byte
15
14
13
12
11
10
9
8
0xFF
−
0x58
R/W
TACH3
Min Low
Byte
7
6
5
4
3
2
1
0
0xFF
−
0x59
R/W
TACH3
Min High
Byte
15
14
13
12
11
10
9
8
0xFF
−
0x5A
R/W
TACH4
Min Low
Byte
7
6
5
4
3
2
1
0
0xFF
−
0x5B
R/W
TACH4
Min High
Byte
15
14
13
12
11
10
9
8
0xFF
−
0x5C
R/W
PWM1
Config.
Register
BHVR
BHVR
BHVR
INV
ALT
SPIN
SPIN
SPIN
0x62
Yes
0x5D
R/W
PWM2
Config.
Register
BHVR
BHVR
BHVR
INV
ALT
SPIN
SPIN
SPIN
0x62
Yes
0x5E
R/W
PWM3
Config.
Register
BHVR
BHVR
BHVR
INV
ALT
SPIN
SPIN
SPIN
0x62
Yes
0x5F
R/W
Remote 1
TRANGE/
PWM1
Frequency
RANGE
RANGE
RANGE
RANGE
HF/LF
FREQ
FREQ
FREQ
0xC4
Yes
0x60
R/W
Local
TRANGE/P
WM2
Frequency
RANGE
RANGE
RANGE
RANGE
HF/LF
FREQ
FREQ
FREQ
0xC4
Yes
0x61
R/W
Remote 2
TRANGE/P
WM3
Frequency
RANGE
RANGE
RANGE
RANGE
HF/LF
FREQ
FREQ
FREQ
0xC4
Yes
www.onsemi.com
45
ADT7490
Table 44. ADT7490 REGISTERS (continued)
Addr
R/W
Desc
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Default
Lockable
0x62
R/W
Enhanced
Acoustics
Reg. 1
MIN3
MIN2
MIN1
SYNC
EN1
ACOU
ACOU
ACOU
0x00
Yes
0x63
R/W
Enhanced
Acoustics
Reg. 2
EN2
ACOU2
ACOU2
ACOU2
EN3
ACOU3
ACOU3
ACOU3
0x00
Yes
0x64
R/W
PWM1
Min Duty
Cycle
7
6
5
4
3
2
1
0
0x80
Yes
0x65
R/W
PWM2
Min Duty
Cycle
7
6
5
4
3
2
1
0
0x80
Yes
0x66
R/W
PWM3
Min Duty
Cycle
7
6
5
4
3
2
1
0
0x80
Yes
0x67
R/W
Remote 1
Temp.
TMIN
7
6
5
4
3
2
1
0
0x5A
Yes
0x68
R/W
Local
Temp.
TMIN
7
6
5
4
3
2
1
0
0x5A
Yes
0x69
R/W
Remote 2
Temp.
TMIN
7
6
5
4
3
2
1
0
0x5A
Yes
0x6A
R/W
Remote 1
THERM
Temp.
Limit
7
6
5
4
3
2
1
0
0x64
Yes
0x6B
R/W
Local
THERM
Temp.
Limit
7
6
5
4
3
2
1
0
0x64
Yes
0x6C
R/W
Remote 2
THERM
Temp.
Limit
7
6
5
4
3
2
1
0
0x64
Yes
0x6D
R/W
Remote 1
and Local
Temp./
TMIN
Hysteresis
HYSR1
HYSR1
HYSR1
HYSR1
HYSL
HYSL
HYSL
HYSL
0x44
Yes
0x6E
R/W
Remote 2
and PECI
Temp./
TMIN
Hysteresis
HYSR2
HYSR2
HYSR2
HYSR2
HYSP
HYSP
HYSP
HYSP
0x44
Yes
0x6F
R/W
XNOR
Tree Test
Enable
RES
RES
RES
RES
RES
RES
RES
XEN
0x00
Yes
0x70
R/W
Remote 1
Temp
Offset
7
6
5
4
3
2
1
0
0x00
Yes
0x71
R/W
Local
Temp.
Offset
7
6
5
4
3
2
1
0
0x00
Yes
0x72
R/W
Remote 2
Temp.
Offset
7
6
5
4
3
2
1
0
0x00
Yes
0x73
R/W
Config.
Reg. 2
Shutdo
wn
CONV
ATTN
AVG
Fan3
Detect
Fan2
Detect
Fan1
Detect
Fan
PresDT
0x00
Yes
0x74
R/W
Interrupt
Mask
Reg. 1
OOL
R2T
LT
R1T
+5VIN
VCC
VCCP
+2.5VIN/
THERM
0x00
−
0x75
R/W
Interrupt
Mask
Reg. 2
D2
FAULT
D1
FAULT
FAN4/
THERM
FAN3
FAN2
FAN1
OOL
+12VIN/
VC
0x00
−
www.onsemi.com
46
ADT7490
Table 44. ADT7490 REGISTERS (continued)
Addr
R/W
Desc
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Default
Lockable
0x76
R
Extended
Resolution
1
+5VIN
+5VIN
VCC
VCC
VCCP
VCCP
+2.5VIN
+2.5VIN
0x00
−
0x77
R
Extended
Resolution
2
TDM2
TDM2
LTMP
LTMP
TDM1
TDM1
+12VIN
+12VIN
0x00
−
0x78
R/W
Config.
Reg. 3
DC4
DC3
DC2
DC1
FAST
BOOST
THERM/
+2.5VIN
ALERT
Enable
0x00
Yes
0x79
R
THERM
Timer
Status
TMR
TMR
TMR
TMR
TMR
TMR
TMR
ASRT/
TMR0
0x00
−
0x7A
R/W
THERM
Timer
Limit
LIMT
LIMT
LIMT
LIMT
LIMT
LIMT
LIMT
LIMT
0x00
−
0x7B
R/W
TACH
Pulses per
Revolution
FAN4
FAN4
FAN3
FAN3
FAN2
FAN2
FAN1
FAN1
0x55
−
0x7C
R/W
Config.
Register 5
R2
THERM
Output
Only
Local
THERM
Output
Only
R1
THERM
Output
Only
PECI
R1
THERM
Output
Only
RES
RES
Temp
Offset
TWOS
COMPL
0x01
Yes
0x7D
R/W
Config.
Register 4
BpAtt
+12VIN
BpAtt
+5VIN
BpAtt
VCCP
BpAtt
+2.5VIN
Max/Full
on
THERM
THERM
Disable
Pin 14
Func
Pin 14
Func
0x00
Yes
0x7E
R
Test 1
DO NOT WRITE TO THIS REGISTER
0x00
Yes
0x7F
R
Test 2
DO NOT WRITE TO THIS REGISTER
0x00
Yes
0x80
R/W
GPIO
Config.
Register
GPIO1
DIR
GPIO2
DIR
GPIO1
POL
GPIO2
POL
GPIO1
GPIO2
RES
RES
0x00
−
0x81
R
Interrupt
Status 4
VTT
IMON
PECI3
PECI2
PECI1
RES
RES
RES
0x00
−
0x82
R/W
Interrupt
Mask 3
OOL
RES
RES
RES
OVT
COMM
DATA
PECI0
0x00
−
0x83
R/W
Interrupt
Mask 4
VTT
IMON
PECI3
PECI2
PECI1
RES
RES
RES
0x00
−
0x84
R/W
VTT Low
Limit
7
6
5
4
3
2
1
0
0x00
Yes
0x85
R/W
IMON Low
Limit
7
6
5
4
3
2
1
0
0x00
Yes
0x86
R/W
VTT High
Limit
7
6
5
4
3
2
1
0
0xFF
Yes
0x87
R/W
IMON High
Limit
7
6
5
4
3
2
1
0
0xFF
Yes
0x88
R/W
PECI
Config. 2
#CPU
#CPU
DOM1
DOM2
DOM3
RES
RES
RES
0x00
Yes
0x89
R
TEST 3
0x00
Yes
0x8A
R/W
PECI
Operating
Point
7
6
5
4
3
2
1
0
0xFB
Yes
0x8B
R/W
Remote 1
Operating
Point
7
6
5
4
3
2
1
0
0x64
Yes
0x8C
R/W
Local
Temp.
Operating
Point
7
6
5
4
3
2
1
0
0x64
Yes
0x8D
R/W
Remote 2
Operating
Point
7
6
5
4
3
2
1
0
0x64
Yes
0x8E
R/W
Dynamic
TMIN
Control
Reg. 1
R2T
LT
R1T
PHTR2
PHTL
PHTR1
VCCPLO
CYR2
0x00
Yes
DO NOT WRITE TO THIS REGISTER
www.onsemi.com
47
ADT7490
Table 44. ADT7490 REGISTERS (continued)
Addr
R/W
Desc
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Default
Lockable
0x8F
R/W
Dynamic
TMIN
Control
Reg. 2
CYR2
CYR2
CYL
CYL
CYL
CYR1
CYR1
CYR1
0x00
Yes
0x90
R/W
Dynamic
TMIN
Control
Reg. 3
PECI
PHTP
CYP
CYP
CYP
RES
RES
RES
0x00
Yes
0x94
R/W
PECI0
Temp.
Offset
7
6
5
4
3
2
1
0
0x00
Yes
0x95
R/W
PECI1
Temp.
Offset
7
6
5
4
3
2
1
0
0x00
Yes
0x96
R/W
PECI2
Temp.
Offset
7
6
5
4
3
2
1
0
0x00
Yes
0x97
R/W
PECI3
Temp.
Offset
7
6
5
4
3
2
1
0
0x00
Yes
−
0x41
−
−
0x74
OOL
R2T
LT
R1T
+5VIN
VCC
VCCP
+2.5VIN/
THERM
Table 45. REGISTER 0x10 − CONFIGURATION REGISTER 6 (POWER-ON DEFAULT = 0x00)
Bit No.
Mnemonic
R/W (Note 1)
Description
[0]
SLOW
Remote 1
R/W
When this bit is set, fan smoothing times are multiplied x4 for Remote 1 temperature channel
(as defined in Register 0x62).
[1]
SLOW
Local
R/W
When this bit is set, fan smoothing times are multiplied x4 for local temperature channel
(as defined in Register 0x63).
[2]
SLOW
Remote 2
R/W
When this bit is set, fan smoothing times are multiplied x4 for Remote 2 temperature channel
(as defined in Register 0x63).
[3]
Res
N/A
Reserved
[4]
Res
N/A
Reserved
[5]
Res
N/A
Reserved
[6]
VCCP Low
R/W
VCCP Low = 1. When the power is supplied from 3.3 V STANDBY and the core voltage
(VCCP) drops below its VCCP low limit value (Register 0x46), the following occurs:
Status Bit 1 in Status Register 1 is set.
SMBALERT is generated, if enabled.
PROCHOT monitoring is disabled.
Everything is re-enabled once VCCP increases above the VCCP low limit.
When VCCP increases above the low limit:
PROCHOT monitoring is enabled.
Fans return to their programmed state after a spin-up cycle.
[7]
ExtraSlow
R/W
When this bit is set, all fan smoothing times are increased by a further 39.2%
1. This register becomes read-only when the Configuration Register 1 (0x40) Lock bit is set to 1. Any subsequent attempts to write to this
register fail.
www.onsemi.com
48
ADT7490
Table 46. REGISTER 0x11 − CONFIGURATION REGISTER 7 (POWER-ON DEFAULT = 0x00)
Bit No.
Mnemonic
R/W (Note 1)
[0]
THERMHys
R/W
THERM hysteresis is enabled by default. Setting this bit to 1 disables THERM hysteresis.
[1]
FSPD
R/W
When set to 1, this bit runs all fans at maximum speed as programmed in the maximum PWM
duty cycle registers (0x38 to 0x3A). Power-on default = 0. This bit is not locked at any time.
[2]
Vx1
R/W
BIOS should set this bit to 1 when the ADT7490 is configured to measure current from an
Analog Devices ADOPT VRM controller and to measure the CPU core voltage. This bit
allows monitoring software to display CPU watts usage. (Lockable.)
[3]
FSPDIS
R/W
Logic 1 disables fan spin-up for two TACH pulses. Instead, the PWM outputs go high for the
entire fan spin-up timeout selected.
[4]
TODIS
R/W
When this bit is set to 1, the SMBus timeout feature is disabled. In this state, if at any point
during an SMBus transaction involving the ADT7490 activity ceases for more than 35 ms, the
ADT7490 assumes the bus is locked and releases the bus. This allows the ADT7490 to be
used with SMBus controllers that cannot handle SMBus timeouts. (Lockable.)
[7:5]
RES
N/A
Reserved. Do not write to these bits.
Description
1. This register becomes read-only when the Configuration Register 1 (0x40) Lock bit is set to 1. Any subsequent attempts to write to this
register fail.
Table 47. PECI READING REGISTERS (POWER-ON DEFAULT = 0x80)
Register Address
R/W
Description
0x33
Read-only
PECI0: This Register Reads the Eight Bits Representative of PECI Client Address 0x30
0x1A
Read-only
PECI1: This Register Reads the Eight Bits Representative of PECI Client Address 0x31
0x1B
Read-only
PECI2: This Register Reads the Eight Bits Representative of PECI Client Address 0x32
0x1C
Read-only
PECI3: This Register Reads the Eight Bits Representative of PECI Client Address 0x33
Table 48. IMON/VTT READING REGISTERS (POWER-ON DEFAULT = 0x00)
Register Address
R/W
0x1D
Read-only
Reflects the voltage measurement at the IMON input on Pin 19 (8 MSBs of reading). Input
range of 0 V to 2.25 V.
Description
0x1E
Read-only
Reflects the voltage measurement at the VTT input on Pin 8 (8 MSBs of reading). Input range
of 0 V to 2.25 V.
Table 49. REGISTER 0x1F − EXTENDED RESOLUTION 3 (POWER-ON DEFAULT = 0x00)
Bit No.
R/W
Description
[3:0]
Read-only
Reserved
[5:4]
Read-only
Hold the Two LSBs of the 10-bit VTT Measurement
[7:6]
Read-only
Hold the Two LSBs of the 10-bit IMON Measurement
Table 50. VOLTAGE READING REGISTERS (POWER-ON DEFAULT = 0x00) (Note 1)
Register Address
R/W
Description
0x20
Read-only
Reflects the Voltage Measurement at the 2.5 VIN Input on Pin 22 (8 MSBs of Reading)
0x21
Read-only
Reflects the Voltage Measurement (Note 2) at the VCCP Input on Pin 23 (8 MSBs of Reading)
0x22
Read-only
Reflects the Voltage Measurement (Note 3) at the VCC Input on Pin 4 (8 MSBs of Reading)
0x23
Read-only
Reflects the Voltage Measurement at the 5 VIN Input on Pin 20 (8 MSBs of Reading)
0x24
Read-only
Reflects the Voltage Measurement at the 12 VIN Input on Pin 21 (8 MSBs of Reading)
1. If the extended resolution bits of these readings are also being read, the extended resolution registers (Register 0x76, Register 0x77) must
be read first. Once the extended resolution registers have been read, the associated MSB reading registers are frozen until read. Both the
extended resolution registers and the MSB registers are frozen.
2. If VCCP Low (Bit 6 of 0x10) is set, VCCP can control the sleep state of the ADT7490.
3. VCC (Pin 4) is the supply voltage for the ADT7490.
www.onsemi.com
49
ADT7490
Table 51. TEMPERATURE READING REGISTERS (POWER-ON DEFAULT = 0x80) (Note 1 and 2)
Register Address
R/W
0x25
Read-only
Remote 1 Temperature Reading (Note 3 and 4) (8 MSBs of Reading)
Description
0x26
Read-only
Local Temperature Reading (8 MSBs of Reading)
0x27
Read-only
Remote 2 Temperature Reading (Note 3 and 4) (8 MSBs of Reading)
1. If the extended resolution bits of these readings are also being read, the extended resolution registers (Register 0x76, Register 0x77) must
be read first. Once the extended resolution registers have been read, all associated MSB reading registers are frozen until read. Both the
extended resolution registers and the MSB registers are frozen.
2. These temperature readings can be in twos complement or Offset 64 format; this interpretation is determined by Bit 0 of Configuration
Register 5 (0x7C).
3. In twos complement mode, a temperature reading of −128°C (0x80) indicates a diode fault (open or short) on that channel.
4. In Offset 64 mode, a temperature reading of −64°C (0x00) indicates a diode fault (open or short) on that channel.
Table 52. FAN TACHOMETER READING REGISTERS (POWER-ON DEFAULT = 0x00) (Note 1)
Register Address
R/W
Description
0x28
Read-only
TACH1 Low Byte
0x29
Read-only
TACH1 High Byte
0x2A
Read-only
TACH2 Low Byte
0x2B
Read-only
TACH2 High Byte
0x2C
Read-only
TACH3 Low Byte
0x2D
Read-only
TACH3 High Byte
0x2E
Read-only
TACH4 Low Byte
0x2F
Read-only
TACH4 High Byte
1. These registers count the number of 11.11Ăms periods (based on an internal 90ĂkHz clock) that occur between a number of consecutive fan TACH
pulses (defaultĂ=Ă2). The number of TACH pulses used to count can be changed using the TACH Pulses per Revolution register (RegisterĂ0x7B).
This allows the fan speed to be accurately measured. Because a valid fan tachometer reading requires that two bytes be read, the low byte must
be read first. Both the low and high bytes are then frozen until read. At power-on, these registers contain 0x0000 until the first valid fan TACH
measurement is read into these registers. This prevents false interrupts from occurring while the fans are spinning up. A count of 0xFFFF
indicates that a fan is one of the following: stalled or blocked (object jamming the fan), failed (internal circuitry destroyed), or not populated. (The
ADT7490 expects to see a fan connected to each TACH. If a fan is not connected to that TACH, its TACH minimum high and low bytes should
be set to 0xFFFF.) An alternate function, for example, is TACH4 reconfigured as the THERM pin.
Table 53. CURRENT PWM DUTY CYCLE REGISTERS (POWER-ON DEFAULT = 0xFF) (Note 1)
Register Address
R/W
Description
0x30
R/W
PWM1 Current Duty Cycle (0% to 100% Duty Cycle = 0x00 to 0xFF)
0x31
R/W
PWM2 Current Duty Cycle (0% to 100% Duty Cycle = 0x00 to 0xFF)
0x32
R/W
PWM3 Current Duty Cycle (0% to 100% Duty Cycle = 0x00 to 0xFF)
1. These registers reflect the PWM duty cycle driving each fan at any given time. When in automatic fan speed control mode, the ADT7490
reports the PWM duty cycles back through these registers. The PWM duty cycle values vary according to temperature in automatic fan speed
control mode. During fan startup, these registers report back 0x00. In manual mode, the PWM duty cycle outputs can be set to any duty cycle
value by writing to these registers.
Table 54. REGISTER 0x33 − PECI0 READING REGISTER (POWER-ON DEFAULT = 0x80)
Register Address
R/W
0x33
Read-only
Description
PECI0: This Register Reads the Eight Bits Representative of PECI Client Address 0x30
Table 55. PECI LIMIT REGISTERS
Register Address
R/W
Description
0x34
R/W
PECI Low Limit
0x81
0x35
R/W
PECI High Limit
0x00
www.onsemi.com
50
Power-On Default
ADT7490
Table 56. REGISTER 0x36 − PECI CONFIGURATION REGISTER 1 (POWER-ON DEFAULT = 0x00)
Bit No.
Mnemonic
R/W (Note 1)
[2:0]
AVG[2:0]
R/W
Description
PECI Smoothing Interval. These bits set the duration over which smoothing is carried out on
the PECI data read. Note that the PECI smoothing interval is equal to the PECI register
update interval. The smoothing interval is calculated using the following formula:
Smooth Interval = #reads × (tBIT × 67 × #CPU + tIDLE)
where:
#reads is the number of readings defined below.
tBIT is the negotiated bit rate.
67 is the number of bits in each PECI reading.
#CPU is the number of CPUs providing PECI data (1 to 4).
tIDLE = 14 ms, the delay between consecutive reads.
Bit Code
Number of PECI Readings
000
001
010
011
100
101
110
111
16
2048
4096
8192
16384
32768
65536
Reserved
[3]
DOM0
R/W
CPU Domain Count information. Set to 0 indicates that CPU 1 associated with the PECI0
reading has a single domain (default). Set to 1 indicates that the system CPU 1 contains two
domains.
[4]
REPLACE
R/W
If this bit is set to 0, it indicates that the ADT7490 is operating in standard mode. If this bit is
set to 1, the Remote 1 Temperature register (Register 0x25) is overwritten by PECI0
information (Register 0x33) and vice versa. Note that in this mode, all associated user
programmable limit and fan control registers are also swapped and should be programmed in
the appropriate PECI or absolute temperature format.
[7:5]
RES
R
Reserved
1. These registers become read-only when the Configuration Register 1 (0x40) Lock bit is set to 1. Any subsequent attempts to write to these
registers fail.
Table 57. MAXIMUM PWM DUTY CYCLE (POWER-ON DEFAULT = 0xFF) (Note 1)
Description
Register Address
R/W (Note 2)
0x38
R/W
Maximum Duty Cycle for PWM1 Output, Default = 100% (0xFF)
0x39
R/W
Maximum Duty Cycle for PWM2 Output, Default = 100% (0xFF)
0x3A
R/W
Maximum Duty Cycle for PWM3 Output, Default = 100% (0xFF)
1. These registers set the maximum PWM duty cycle of the PWM output.
2. These registers become read-only when the Configuration Register 1 (0x40) Lock bit is set to 1. Any subsequent attempts to write to these
registers fail.
Table 58. PECI TMIN REGISTER (POWER-ON DEFAULT = 0xE0, VALUE = −32)
Register Address
R/W (Note 1)
0x3B
R/W
Description
PECI TMIN. When the PECI measurement exceeds PECI TMIN, the appropriate fans run at
PWMMIN and increase according to the automatic fan speed control slope.
1. This register becomes read-only when the Configuration Register 1 (0x40) Lock bit is set. Any further attempts to write to this register have
no effect.
www.onsemi.com
51
ADT7490
Table 59. REGISTER 0x3C − PECI TRANGE/ENHANCED ACOUSTICS REGISTER (POWER-ON DEFAULT = 0xC0)
Bit No.
Mnemonic
R/W
(Note 1)
[2:0]
ACOU
R/W
Description
Assuming that PWMx is associated with the PECI channel, these bits define the maximum
rate of change of the PWMx output for PECI temperature-related changes. Instead of the fan
speed jumping instantaneously to its newly determined speed, it ramps gracefully at the rate
determined by these bits. This feature ultimately enhances the acoustics of the fan. The
smoothing times below are based on a refresh rate of the round robin cycle. The PECI data,
for 0% to 100%, must be multiplied each time by:
PECI Refresh Rate
Round Robin Cycle
where the PECI refresh rate is defined in Register 0x36 and the round robin cycle is typically
165 ms.
When Bit 7 of Configuration Register 6 (0x10) is 0
Bit Code
Time for 0% to 100%
000 = 1
001 = 2
010 = 3
011 = 4
100 = 8
101 = 12
110 = 24
111 = 48
37.5 sec
18.8 sec
12.5 sec
7.5 sec
4.7 sec
3.1 sec
1.6 sec
0.8 sec
When Bit 7 of Configuration Register 6 (0x10) is 1
Bit Code
Time for 0% to 100%
000 = 1
001 = 2
010 = 3
011 = 4
100 = 8
101 = 12
110 = 24
111 = 48
52.2 sec
26.1 sec
17.4 sec
10.4 sec
6.5 sec
4.4 sec
2.2 sec
1.1 sec
[3]
ENP
R/W
When this bit is set to 1, smoothing is enabled on the PECI channel allowing enhanced
acoustics on the associated PWM output.
[7:4]
RANGE
R/W
These bits determine the PWM duty cycle vs. the temperature range for automatic fan
control.
Bit Code
Temperature
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
2°C
2.5°C
3.33°C
4°C
5°C
6.67°C
8°C
10°C
13.33°C
16°C
20°C
26.67°C
32°C (Default)
40°C
53.33°C
80°C
1. This register becomes read-only when the Configuration Register 1 (0x40) Lock bit is set to 1. Any subsequent attempts to write to this
register fail.
www.onsemi.com
52
ADT7490
Table 60. TCONTROL LIMIT REGISTER (POWER-ON DEFAULT = 0x00) (Note 1)
Register Address
R/W (Note 2)
0x3D
R/W
Description
PECI TCONTROL Limit
1. If any PECI reading exceeds the TCONTROL limit, all PWM outputs drive their fans at 100% duty cycle. This is a fail-safe mechanism
incorporated to cool the system in the event of a critical overtemperature. It also ensures some level of cooling in the event that software
or hardware locks up. If set to 0x80, this feature is disabled. The PWM output remains at 100% until the temperature drops below
TCONTROL limit − hysteresis.
2. This register becomes read-only when the Configuration Register 1 (0x40) Lock bit is set to 1. Any further attempts to write to this register
have no effect.
Table 61. REGISTER 0x3F − VERSION REGISTER
Bit No.
Mnemonic
R/W
[1:0]
REV[1:0]
Read-only
These two bits indicate the ADT7490 silicon revision number. 0x00 indicates Revision 0,
0x01 indicates Revision 1, and so on. 0x11 indicates that further revision information can be
found in the “Extended Revision” register (0x12). The revision number is then found by
adding 0x11 to the contents of the extended revision register.
Description
[2]
PECI
Read-only
This bit is set to 1 indicating that the ADT7490 supports the PECI interface.
[3]
4-wire
Read-only
This bit is set to 1 indicating that the ADT7490 may be configured to drive 4-wire fans using
high frequency PWM.
[7:4]
VER[3:0]
Read-only
These bits indicate the version number of the device. This is set to 6, indicating that the
ADT7490 is part of the Heceta 6 ASIC family.
Table 62. REGISTER 0x40 − CONFIGURATION REGISTER 1 (POWER-ON DEFAULT = 0x04)
Bit No.
Mnemonic
R/W (Note 1)
Description
[0]
STRT
(Notes 2, 3)
R/W
Logic 1 enables monitoring and PWM control outputs based on the limit settings
programmed. Logic 0 disables monitoring and PWM control is based on the default powerup
limit settings. Note that the limit values programmed are preserved even if a Logic 0 is written
to this bit and the default settings are enabled. This bit does not become locked once Bit 1
(Lock bit) is set.
[1]
LOCK
Write once
Logic 1 locks all limit values to their current settings. Once this bit is set, all lockable registers
become read-only and cannot be modified until the ADT7490 is powered down and powered
up again. This prevents rogue programs such as viruses from modifying critical system limit
settings. (Lockable.)
[2]
RDY
Read-only
This bit is set to 1 by the ADT7490 to indicate that the device is fully powered up and ready
to begin system monitoring.
[3]
Fan Boost
R/W
When this bit is set to Logic 1, all PWM outputs go to 100% regardless of other fan speed
configurations and automatic fan speed control settings. When this bit is set to 0, the fan
speed control returns to the fan speed setting calculated by the preprogrammed fan speed
control settings. This bit remains writable after the Lock bit is set.
[4]
PECI
Monitor
R/W
Set this bit to Logic 1 to enable CPU thermal monitoring via PECI interface. This bit becomes
read-only when the Lock bit is set.
[5]
THERM in
Manual
R/W
When this bit is set to Logic 1, THERM is enabled so that the fans go to 100% duty cycle on a
THERM or TCONTROL assertion overriding any other fan setting, even when the PWMs are
configured for manual mode, or disabled. This bit becomes read-only when the Lock bit is set.
[7:6]
RES
Read-only
Reserved.
1. This register becomes read-only when the Configuration Register 1 (0x40) Lock bit is set to 1. Any subsequent attempts to write to this
register fail.
2. Bit 0 (STRT) of Configuration Register 1 (0x40) remains writable after the Lock bit is set.
3. When monitoring (STRT) is disabled, PWM outputs always go to 100% for thermal protection.
www.onsemi.com
53
ADT7490
Table 63. REGISTER 0x41 − INTERRUPT STATUS REGISTER 1 (POWER-ON DEFAULT = 0x00)
Bit No.
Mnemonic
R/W
Description
[0]
+2.5 VIN/
THERM
Read-only
+2.5 VIN = 1 indicates that the 2.5 VIN high or low limit has been exceeded. This bit is cleared
on a read of the status register only if the error condition has subsided. If Pin 22 is configured
as THERM, this bit is asserted when the timer limit has been exceeded.
[1]
VCCP
Read-only
VCCP = 1 indicates that the VCCP high or low limit has been exceeded. This bit is cleared on
a read of the status register only if the error condition has subsided.
[2]
VCC
Read-only
VCC = 1 indicates that the VCC high or low limit has been exceeded. This bit is cleared on a
read of the status register only if the error condition has subsided.
[3]
+5 VIN
Read-only
+5 VIN = 1 indicates that the 5 VIN high or low limit has been exceeded. This bit is cleared on
a read of the status register only if the error condition has subsided.
[4]
R1T
Read-only
R1T = 1 indicates that the Remote 1 low or high temperature has been exceeded. This bit is
cleared on a read of the status register only if the error condition has subsided.
[5]
LT
Read-only
LT = 1 indicates that the local low or high temperature has been exceeded. This bit is cleared
on a read of the status register only if the error condition has subsided.
[6]
R2T
Read-only
R2T = 1 indicates that the Remote 2 low or high temperature has been exceeded. This bit is
cleared on a read of the status register only if the error condition has subsided.
[7]
OOL
Read-only
OOL = 1 indicates that an out-of-limit event has been latched in Interrupt Status Register 2
(0x42). This bit is a logical OR of all status bits in Interrupt Status Register 2. Software can
test this bit in isolation to determine whether any of the voltage, temperature, or fan speed
readings represented by Interrupt Status Register 2 are out-of-limit, which eliminates the
need to read Interrupt Status Register 2 during every interrupt or polling cycle.
Table 64. REGISTER 0x42 − INTERRUPT STATUS REGISTER 2 (POWER-ON DEFAULT = 0x00)
Bit No.
Mnemonic
R/W
Description
[0]
+12 VIN
Read-only
+12 VIN = 1 indicates that the 12 VIN high or low limit has been exceeded. This bit is cleared
on a read of the status register only if the error condition has subsided.
[1]
OOL
Read-only
OOL = 1 indicates that an out-of-limit event has been latched in Interrupt Status Register 3
(0x43). This bit is a logical OR of all status bits in Interrupt Status Register 3. Software can
test this bit in isolation to determine whether any of the voltage, temperature, or fan speed
readings represented by Interrupt Status Register 3 are out-of-limit, which eliminates the
need to read Interrupt Status Register 3 during every interrupt or polling cycle.
[2]
FAN1
Read-only
FAN1 = 1 indicates that Fan 1 has dropped below minimum speed or has stalled. This bit is
not set when the PWM1 output is off.
[3]
FAN2
Read-only
FAN2 = 1 indicates that Fan 2 has dropped below minimum speed or has stalled. This bit is
not set when the PWM2 output is off.
[4]
FAN3
Read-only
FAN3 = 1 indicates that Fan 3 has dropped below minimum speed or has stalled. This bit is
not set when the PWM3 output is off.
[5]
FAN4/
THERM
Read-only
When Pin 14 is programmed as a TACH4 input, FAN4 = 1 indicates that Fan 4 has dropped
below minimum speed or has stalled. This bit is not set when the PWM3 output is off.
If Pin 14 is configured as the THERM timer input for THERM monitoring, this bit is set when
the THERM assertion time exceeds the limit programmed in the THERM timer limit register
(Register 0x7A).
[6]
D1 FAULT
Read-only
D1 FAULT = 1 indicates either an open or short circuit on the Thermal Diode 1 inputs.
[7]
D2 FAULT
Read-only
D2 FAULT = 1 indicates either an open or short circuit on the Thermal Diode 2 inputs.
www.onsemi.com
54
ADT7490
Table 65. REGISTER 0x43 − INTERRUPT STATUS REGISTER 3 (POWER-ON DEFAULT = 0x00)
Bit No.
Mnemonic
R/W
Description
[0]
PECI0
Read-only
A Logic 1 indicates that the PECI high or low limit has been exceeded by the PECI value
from PECI Client Address 0x30. This bit is cleared on a read of the status register only if the
error condition has subsided.
[1]
DATA
Read-only
A Logic 1 indicates that valid PECI data cannot be obtained for the processor and a specified
error code has been recorded.
[2]
COMM
Read-only
A Logic 1 indicates that there is a communications error (for example, invalid FCS) on the
PECI interface.
[3]
OVT
(THERM
Temp Limit)
Read-only
OVT = 1 indicates that one of the THERM overtemperature limits has been exceeded. This bit
is cleared on a read of the status register when the temperature drops below THERM − THYST.
[6:4]
RES
Read-only
Reserved
[7]
OOL
Read-only
OOL = 1 indicates that an out-of-limit event has been latched in Interrupt Status Register 4
(0x81). This bit is a logical OR of all status bits in Interrupt Status Register 4. Software can
test this bit in isolation to determine whether any of the voltage, temperature, or fan speed
readings represented by Interrupt Status Register 4 are out-of-limit, which eliminates the need
to read Interrupt Status Register 4 during every interrupt or polling cycle.
Table 66. VOLTAGE LIMIT REGISTERS (Note 1)
Description (Note 2)
Register Address
R/W
0x44
R/W
+2.5 VIN Low Limit
Power-On Default
0x00
0x45
R/W
+2.5 VIN High Limit
0xFF
0x46
R/W
VCCP Low Limit
0x00
0x47
R/W
VCCP High Limit
0xFF
0x48
R/W
VCC Low Limit
0x00
0x49
R/W
VCC High Limit
0xFF
0x4A
R/W
+5 VIN Low Limit
0x00
0x4B
R/W
+5 VIN High Limit
0xFF
0x4C
R/W
+12 VIN Low Limit
0x00
0x4D
R/W
+12 VIN High Limit
0xFF
1. Setting the Configuration Register 1 (0x40) Lock bit has no effect on these registers.
2. High limits: An interrupt is generated when a value exceeds its high limit (> comparison). Low limits: An interrupt is generated when a value
is equal to or below its low limit (≤ comparison).
Table 67. TEMPERATURE LIMIT REGISTERS (Note 1)
Description (Note 2)
Register Address
R/W
0x4E
R/W
Remote 1 Temperature Low Limit
Power-On Default
0x81
0x4F
R/W
Remote 1 Temperature High Limit
0x7F
0x50
R/W
Local Temperature Low Limit
0x81
0x51
R/W
Local Temperature High Limit
0x7F
0x52
R/W
Remote 2 Temperature Low Limit
0x81
0x53
R/W
Remote 2 Temperature High Limit
0x7F
1. Exceeding any of these temperature limits by 1°C causes the appropriate status bit to be set in the interrupt status register. Setting the
Configuration Register 1 (0x40) Lock bit has no effect on these registers.
2. High limits: An interrupt is generated when a value exceeds its high limit (> comparison). Low limits: An interrupt is generated when a value
is equal to or below its low limit (≤ comparison).
www.onsemi.com
55
ADT7490
Table 68. FAN TACHOMETER LIMIT REGISTERS (Note 1)
Register Address
R/W
0x34
R/W
PECI Low Limit
Description
Power-On Default
0x81
0x54
R/W
TACH1 Minimum Low Byte
0xFF
0x55
R/W
TACH1 Minimum High Byte/Single-channel ADC Channel Select
0xFF
0x56
R/W
TACH2 Minimum Low Byte
0xFF
0x57
R/W
TACH2 Minimum High Byte
0xFF
0x58
R/W
TACH3 Minimum Low Byte
0xFF
0x59
R/W
TACH3 Minimum High Byte
0xFF
0x5A
R/W
TACH4 Minimum Low Byte
0xFF
0x5B
R/W
TACH4 Minimum High Byte
0xFF
1. Exceeding any of the TACH limit registers by 1 indicates that the fan is running too slowly or has stalled. The appropriate status bit is set
in Interrupt Status Register 2 (0x42) to indicate fan failure. Setting the Configuration Register 1 (0x40) Lock bit has no effect on these
registers.
Table 69. REGISTER 0x55 − TACH1 MINIMUM HIGH BYTE (POWER-ON DEFAULT = 0xFF)
Bit No.
Mnemonic
R/W
Description
[3:0]
Reserved
Read-only
When Bit 6 of Configuration 2 Register (0x73) is set (single-channel ADC mode), these bits
are reserved. Otherwise, these bits represent Bits [3:0] of the TACH1 minimum high byte.
[7:4]
SCADC
R/W
When Bit 6 of Configuration 2 Register (0x73) is set (single-channel ADC mode), these bits
are used to select the only channel from which the ADC will take measurements. Otherwise,
these bits represent Bits [7:4] of the TACH1 minimum high byte.
Bit Code
Single-channel Select
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
+2.5 VIN
VCCP
VCC
+5 VIN
+12 VIN
Remote 1 Temperature
Local Temperature
Remote 2 Temperature
VTT
IMON
Table 70. PWM CONFIGURATION REGISTERS
Register Address
R/W (Note 1)
Description
Power-On Default
0x34
R/W
PECI Low Limit
0x81
0x5C
R/W
PWM1 Configuration
0x62
0x5D
R/W
PWM2 Configuration
0x62
0x5E
R/W
PWM3 Configuration
0x62
1. These registers become read-only when the Configuration Register 1 (0x40) Lock bit is set to 1. Any subsequent attempts to write to these
registers fail.
www.onsemi.com
56
ADT7490
Table 71. REGISTER 0x5C, REGISTER 0x5D, AND REGISTER 0x5E − PWM1, PWM2, AND PWM3 CONFIGURATION
REGISTERS (POWER-ON DEFAULT = 0x62)
Bit No.
Mnemonic
R/W (Note 1)
Description
[2:0]
SPIN
R/W
These bits control the startup timeout for PWMx. The PWM output stays high until two valid
TACH rising edges are seen from the fan. If there is not a valid TACH signal during the fan
TACH measurement directly after the fan startup timeout period, the TACH measurement reads
0xFFFF and Interrupt Status Register 2 reflects the fan fault. If the TACH minimum high and
low bytes contain 0xFFFF or 0x0000, then the Interrupt Status Register 2 bit is not set, even if
the fan has not started.
Bit Code
Startup Time
000
001
010
011
100
101
110
111
No Startup Timeout
100 ms
250 ms (Default)
400 ms
667 ms
1 sec
2 sec
4 sec
[3]
ALT
R/W
Use alternative behavior setting options in Bits [7:5] below for PWMx by setting this bit to 1.
Default = 0.
[4]
INV
R/W
This bit inverts the PWM output. The default is 0, which corresponds to a logic high output for
100% duty cycle. Setting this bit to 1 inverts the PWM output, so a 100% duty cycle
corresponds to a logic low output.
[7:5]
BHVR
(Note 2)
R/W
These bits assign each fan to a particular temperature sensor for localized cooling. Setting Bit 3
to Logic 1 in this register chooses whether the default of alternative behavior option is selected.
Default Behavior Bits
Alternative Behavior Bits (Note 2)
000 = Remote 1 temperature controls
PWMx (automatic fan control mode).
000 = PECI0 reading controls PWMx
(automatic fan control mode).
001 = Local temperature controls PWMx
(automatic fan control mode).
001 = PECI1 reading controls PWMx
(automatic fan control mode).
010 = Remote 2 temperature controls
PWMx (automatic fan control mode).
010 = PECI2 reading controls PWMx
(automatic fan control mode).
011 = PWMx runs full speed (default).
011 = PECI3 reading controls PWMx
(automatic fan control mode).
100 = PWMx disabled.
100 = Reserved. If selected, fans run at 100%
duty cycle.
101 = Fastest speed calculated by local
and Remote 2 temperature controls PWMx.
101 = Fastest of all four PECI channels. Fastest
speed calculated by all four PECI readings.
110 = Fastest speed calculated by all three
temperature channel controls PWMx.
110 = Reserved. If selected, fans run at 100%
duty cycle.
111 = Manual mode. PWM duty cycle
registers (Register 0x30 to Register 0x32)
become writable.
111 = Fastest speed calculated by all of the
thermal zones (Local, Remote 1, Remote 2,
and PECI temperatures).
1. This register becomes read-only when the Configuration Register 1 (0x40) Lock bit is set to 1. Any subsequent attempts to write to this
register fail.
2. When REPLACE mode is selected, (Register 0x36, Bit 4 set to 1) PWM1 is automatically configured for the alternative behavior setting.
Register 0x36, Bits [7:5] should be set to 000 only.
Table 72. TEMPERATURE TRANGE/PWM FREQUENCY REGISTERS
Register Address
R/W (Note 1)
0x5F
R/W
Remote 1 TRANGE/PWM1 Frequency
0xC4
0x60
R/W
Local TRANGE/PWM2 Frequency
0xC4
0x61
R/W
Remote 2 TRANGE/PWM3 Frequency
0xC4
Description
Power-On Default
1. These registers become read-only when the Configuration Register 1 (0x40) Lock bit is set. Any further attempts to write to these registers
have no effect.
www.onsemi.com
57
ADT7490
Table 73. REGISTER 0x5F, REGISTER 0x60, AND REGISTER 0x61 − REMOTE 1 TRANGE/PWM1 FREQUENCY,
LOCAL TRANGE/PWM2 FREQUENCY, AND REMOTE 2 TRANGE/PWM3 FREQUENCY (POWER-ON DEFAULT = 0xC4)
Bit No.
Mnemonic
R/W (Note 1)
[2:0]
FREQ
R/W
Description
These bits control the PWMx frequency (only apply when PWM channel is in low frequency
mode).
Bit Code
000
001
010
011
100
101
110
111
Frequency
11.0 Hz
14.7 Hz
22.1 Hz
29.4 Hz
35.3 Hz (Default)
44.1 Hz
58.8 Hz
88.2 Hz
[3]
HF/LF
R/W
HF/LF = 1, high frequency PWM mode is enabled for PWMx.
HF/LF = 0, low frequency PWM mode is enabled for PWMx.
[7:4]
RANGE
R/W
These bits determine the PWM duty cycle vs. the temperature range for automatic fan
control.
Bit Code
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
Temperature
2°C
2.5°C
3.33°C
4°C
5°C
6.67°C
8°C
10°C
13.33°C
16°C
20°C
26.67°C
32°C (Default)
40°C
53.33°C
80°C
1. This register becomes read-only when the Configuration Register 1 (0x40) Lock bit is set. Any further attempts to write to this register have
no effect.
www.onsemi.com
58
ADT7490
Table 74. REGISTER 0x62 − ENHANCED ACOUSTICS REGISTER 1 (POWER-ON DEFAULT = 0x00)
Bit No.
Mnemonic
[2:0]
ACOU
(Note 2)
R/W
(Note 1)
R/W
Description
Assuming that PWMx is associated with the Remote 1 temperature channel, these bits define
the maximum rate of change of the PWMx output for Remote 1 temperature-related changes.
Instead of the fan speed jumping instantaneously to its newly determined speed, it ramps
gracefully at the rate determined by these bits. This feature ultimately enhances the acoustics
of the fan.
When Bit 7 of Configuration Register 6 (0x10) is 0
Bit Code
Time for 0% to 100%
000 = 1
001 = 2
010 = 3
011 = 4
100 = 8
101 = 12
110 = 24
111 = 48
37.5 sec
18.8 sec
12.5 sec
7.5 sec
4.7 sec
3.1 sec
1.6 sec
0.8 sec
When Bit 7 of Configuration Register 6 (0x10) is 1
Bit Code
Time for 0% to 100%
000 = 1
001 = 2
010 = 3
011 = 4
100 = 8
101 = 12
110 = 24
111 = 48
52.2 sec
26.1 sec
17.4 sec
10.4 sec
6.5 sec
4.4 sec
2.2 sec
1.1 sec
[3]
EN1
R/W
When this bit is 1, smoothing is enabled on Remote 1 temperature channel.
[4]
SYNC
R/W
SYNC = 1 synchronizes fan speed measurements on TACH2, TACH3, and TACH4 to PWM3.
This allows up to three fans to be driven from PWM3 output and their speeds to be measured.
SYNC = 0 synchronizes only TACH3 and TACH4 to PWM3 output.
[5]
MIN1
R/W
When the ADT7490 is in automatic fan control mode, this bit defines whether PWM1 is off
(0% duty cycle) or at PWM1 minimum duty cycle when the controlling temperature is below
its TMIN − hysteresis value.
0 = 0% duty cycle below TMIN – hysteresis.
1 = PWM1 minimum duty cycle below TMIN – hysteresis.
[6]
MIN2
R/W
When the ADT7490 is in automatic fan speed control mode, this bit defines whether PWM2 is
off (0% duty cycle) or at PWM2 minimum duty cycle when the controlling temperature is
below its TMIN − hysteresis value.
0 = 0% duty cycle below TMIN – hysteresis.
1 = PWM2 minimum duty cycle below TMIN – hysteresis.
[7]
MIN3
R/W
When the ADT7490 is in automatic fan speed control mode, this bit defines whether PWM3 is
off (0% duty cycle) or at PWM3 minimum duty cycle when the controlling temperature is
below its TMIN – hysteresis value.
0 = 0% duty cycle below TMIN – hysteresis.
1 = PWM3 minimum duty cycle below TMIN – hysteresis.
1. This register becomes read-only when the Configuration Register 1 (0x40) Lock bit is set to 1. Any further attempts to write to this register
have no effect.
2. Setting the relevant bit of Configuration Register 6 (0x10, Bits [2:0]) further decreases these ramp rates by a factor of 4.
www.onsemi.com
59
ADT7490
Table 75. REGISTER 0x63 − ENHANCED ACOUSTICS REGISTER 2 (POWER-ON DEFAULT = 0x00)
Bit No.
Mnemonic
R/W (Note 1)
Description
[2:0]
ACOU2
R/W
Assuming that PWMx is associated with the local temperature channel, these bits define the
maximum rate of change of the PWMx output for local temperature-related changes. Instead of
the fan speed jumping instantaneously to its newly determined speed, it ramps gracefully at the
rate determined by these bits. This feature ultimately enhances the acoustics of the fan.
When Bit 7 of Configuration Register 6 (0x10) is 0
Bit Code
Time for 0% to 100%
000 = 1
001 = 2
010 = 3
011 = 4
100 = 8
101 = 12
110 = 24
111 = 48
37.5 sec
18.8 sec
12.5 sec
7.5 sec
4.7 sec
3.1 sec
1.6 sec
0.8 sec
When Bit 7 of Configuration Register 6 (0x10) is 1
Bit Code
000 = 1
001 = 2
010 = 3
011 = 4
100 = 8
101 = 12
110 = 24
111 = 48
Time for 0% to 100%
52.2 sec
26.1 sec
17.4 sec
10.4 sec
6.5 sec
4.4 sec
2.2 sec
1.1 sec
[3]
EN2
R/W
When this bit is 1, smoothing is enabled on the local temperature channel.
[6:4]
ACOU3
R/W
Assuming that PWMx is associated with the Remote 2 temperature channel, these bits define
the maximum rate of change of the PWMx output for Remote 2 Temperature related
changes. Instead of the fan speed jumping instantaneously to its newly determined speed, it
ramps gracefully at the rate determined by these bits. This feature ultimately enhances the
acoustics of the fan.
[7]
EN3
R/W
When this bit is 1, smoothing is enabled on the Remote 2 temperature channel.
1. This register becomes read-only when the Configuration Register 1 (0x40) Lock bit is set to 1. Any further attempts to write to this register
have no effect.
Table 76. PWM MINIMUM DUTY CYCLE REGISTERS
Register Address
R/W (Note 1)
0x64
R/W
PWM1 Minimum Duty Cycle
0x80 (50% Duty Cycle)
0x65
R/W
PWM2 Minimum Duty Cycle
0x80 (50% Duty Cycle)
0x66
R/W
PWM3 Minimum Duty Cycle
0x80 (50% Duty Cycle)
Description
Power-On Default
1. These registers become read-only when the ADT7490 is in automatic fan control mode.
Table 77. REGISTER 0x64, REGISTER 0x65, AND REGISTER 0x66 − PWM1, PWM2, AND PWM3 MIN DUTY CYCLES
(POWER-ON DEFAULT = 0x80)
Register Address
R/W (Note 1)
[7:0]
R/W
Description
These bits define the PWMMIN duty cycle for PWMx.
0x00 = 0% Duty Cycle (Fan Off)
0x40 = 25% Duty Cycle
0x80 = 50% Duty Cycle
0xFF = 100% Duty Cycle (Fan Full Speed)
1. This register becomes read-only when the Configuration Register 1 (0x40) Lock bit is set to 1. Any further attempts to write to this register
have no effect.
www.onsemi.com
60
ADT7490
Table 78. TMIN REGISTERS (Note 1)
Register Address
R/W (Note 2)
0x67
R/W
Remote 1 Temperature TMIN
0x5A (90°C)
0x68
R/W
Local Temperature TMIN
0x5A (90°C)
0x69
R/W
Remote 2 Temperature TMIN
0x5A (90°C)
Description
Power-On Default
1. These are the TMIN registers for each temperature channel. When the temperature measured exceeds TMIN, the appropriate fan runs at
minimum speed and increases with temperature according to TRANGE.
2. These registers become read-only when the Configuration Register 1 (0x40) Lock bit is set. Any further attempts to write to these registers
have no effect.
Table 79. THERM LIMIT REGISTERS (Note 1)
Register Address
R/W (Note 2)
0x6A
R/W
Remote 1 THERM Temperature Limit
0x64 (100°C)
0x6B
R/W
Local THERM Temperature Limit
0x64 (100°C)
0x6C
R/W
Remote 2 THERM Temperature Limit
0x64 (100°C)
Description
Power-On Default
1. If any temperature measured exceeds its THERM limit, all PWM outputs drive their fans at 100% duty cycle. This is a fail-safe mechanism
incorporated to cool the system in the event of a critical over temperature. It also ensures some level of cooling in the event that software
or hardware locks up. If set to 0x80, this feature is disabled. The PWM output remains at 100% until the temperature drops below
THERM limit − hysteresis. If the THERM pin is programmed as an output, exceeding these limits by 0.25°C can cause the THERM pin to
assert low as an output.
2. These registers become read-only when the Configuration Register 1 (0x40) Lock bit is set to 1. Any further attempts to write to these
registers have no effect.
Table 80. TEMPERATURE/TMIN HYSTERESIS REGISTERS
Register Address
R/W (Note 1)
0x6D
R/W
Remote 1 and Local Temperature/TMIN Hysteresis
0x44
0x6E
R/W
PECI and Remote 2 Temperature/TMIN Hysteresis
0x44
Description
Power-On Default
1. These registers become read-only when the Configuration Register 1(0x40) Lock bit is set to 1. Any further attempts to write to these registers
have no effect.
Table 81. REGISTER 0x6D − REMOTE 1 AND LOCAL TEMPERATURE/TMIN HYSTERESIS
(POWER-ON DEFAULT = 0x44)
Bit No.
(Note 1)
Mnemonic
R/W
(Note 2)
[3:0]
HYSL
R/W
Local temperature hysteresis. 0°C to 15°C of hysteresis can be applied to the Local
temperature AFC control loops.
[7:4]
HYSR1
R/W
Remote 1 temperature hysteresis. 0°C to 15°C of hysteresis can be applied to the Remote 1
Temperature AFC control loops.
Description
1. Each 4-bit value controls the amount of temperature hysteresis applied to a particular temperature channel. Once the temperature for that
channel falls below its TMIN value, the fan remains running at PWMMIN duty cycle until the temperature = TMIN − hysteresis. Up to 15°C of
hysteresis can be assigned to any temperature channel. The hysteresis value chosen also applies to that temperature channel if its THERM
limit is exceeded. The PWM output being controlled goes to 100%, if the THERM limit is exceeded and remains at 100% until the temperature
drops below THERM − hysteresis. For acoustic reasons, it is recommended that the hysteresis value not be programmed less than 4°C. Setting
the hysteresis value lower than 4°C causes the fan to switch on and off regularly when the temperature is close to TMIN.
2. These registers become read-only when the Configuration Register 1 Lock bit is set to 1. Any further attempts to write to these registers have
no effect.
www.onsemi.com
61
ADT7490
Table 82. REGISTER 0x6E − REMOTE 2 AND PECI TEMPERATURE/TMIN HYSTERESIS
(POWER-ON DEFAULT = 0x44)
Bit No.
(Note 1)
Mnemonic
R/W
(Note 2)
[3:0]
HYSP
R/W
PECI temperature hysteresis. 0°C to 15°C of hysteresis can be applied to the PECI AFC
control loops.
[7:4]
HYSR2
R/W
Remote 2 temperature hysteresis. 0°C to 15°C of hysteresis can be applied to the local
temperature AFC control loops.
Description
1. Each 4-bit value controls the amount of temperature hysteresis applied to a particular temperature channel. Once the temperature for that
channel falls below its TMIN value, the fan remains running at PWMMIN duty cycle until the temperature = TMIN − hysteresis. Up to 15°C of
hysteresis can be assigned to any temperature channel. The hysteresis value chosen also applies to that temperature channel, if its THERM
limit is exceeded. The PWM output being controlled goes to 100%, if the THERM limit is exceeded and remains at 100% until the temperature
drops below THERM − hysteresis. For acoustic reasons, it is recommended that the hysteresis value not be programmed less than 4°C. Setting
the hysteresis value lower than 4°C causes the fan to switch on and off regularly when the temperature is close to TMIN.
2. These registers become read-only when the Configuration Register 1 (0x40) Lock bit is set to 1. Any further attempts to write to these
registers have no effect.
Table 83. REGISTER 0x6F − XNOR TREE TEST ENABLE (POWER-ON DEFAULT = 0x00)
Bit No.
Mnemonic
R/W (Note 1)
[0]
XEN
R/W
If the XEN bit is set to 1, the device enters the XNOR tree test mode. Clearing the bit
removes the device from the XNOR tree test mode.
[7:1]
RES
R/W
Unused/reserved. Do not write to these bits.
Description
1. This register becomes read-only when the Configuration Register 1 (0x40) Lock bit is set to 1. Any further attempts to write to this register
have no effect.
Table 84. REGISTER 0x70 − REMOTE 1 TEMPERATURE OFFSET (POWER-ON DEFAULT = 0x00)
Bit No.
R/W (Note 1)
Description
[7:0]
R/W
Allows a temperature offset to be automatically applied to the Remote 1 temperature channel measurement.
Bit 1 of Configuration Register 5 (0x7C) determines the range and resolution of this register.
1. This register becomes read-only when the Configuration Register 1 (0x40) Lock bit is set to 1. Any further attempts to write to this register
have no effect.
Table 85. REGISTER 0x71 − LOCAL TEMPERATURE OFFSET (POWER-ON DEFAULT = 0x00)
Bit No.
R/W (Note 1)
[7:0]
R/W
Description
Allows a temperature offset to be automatically applied to the local temperature measurement. Bit 1 of
Configuration Register 5 (0x7C) determines the range and resolution of this register.
1. This register becomes read-only when the Configuration Register 1 (0x40) Lock bit is set to 1. Any further attempts to write to this register
have no effect.
Table 86. REGISTER 0x72 − REMOTE 2 TEMPERATURE OFFSET (POWER-ON DEFAULT = 0x00)
Bit No.
R/W (Note 1)
Description
[7:0]
R/W
Allows a temperature offset to be automatically applied to the Remote 2 temperature channel measurement.
Bit 1 of Configuration Register 5 (0x7C) determines the range and resolution of this register.
1. This register becomes read-only when the Configuration Register 1 (0x40) Lock bit is set to 1. Any further attempts to write to this register
have no effect.
www.onsemi.com
62
ADT7490
Table 87. REGISTER 0x73 − CONFIGURATION REGISTER 2 (POWER-ON DEFAULT = 0x00)
Bit No.
Mnemonic
R/W (Note 1)
0
FanPresDT
R/W
1
Fan1Detect
Read-only
Fan1Detect = 1 indicates that a 4-wire fan is connected to the PWM1 input.
2
Fan2Detect
Read-only
Fan2Detect = 1 indicates that a 4-wire fan is connected to the PWM2 input.
3
Fan3Detect
Read-only
Fan3Detect = 1 indicates that a 4-wire fan is connected to the PWM3 input.
4
AVG
R/W
AVG = 1 indicates that averaging on the temperature and voltage measurements is turned
off. This allows measurements on each channel to be made much faster (x16).
5
ATTN
R/W
ATTN = 1 indicates that the ADT7490 removes the attenuators from the +2.5 VIN, VCCP,
+5 VIN, and +12 VIN inputs. These inputs can be used for other functions such as connecting
up external sensors. It is also possible to remove attenuators from individual channels using
Bits [7:4] of Configuration Register 4 (0x7D).
6
CONV
R/W
CONV = 1 indicates that the ADT7490 is put into a single-channel ADC conversion mode. In
this mode, the ADT7490 can be made to read continuously from one input only, for example,
Remote 1 temperature. The appropriate ADC channel is selected by writing to Bits [7:4] of
TACH1 minimum high byte register (0x55).
When CONV = 1, Bits [7:4], Register 0x55
7
Shutdown
R/W
Description
When FanPresDT = 1, the state of Bits [3:1] of this register reflects the presence of a 4-wire
fan on the appropriate TACH channel.
Bit Code
ADC Channel Selected
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
+2.5 VIN
VCCP
VCC
+5 VIN
+12 VIN
Remote 1 Temperature
Local Temperature
Remote 2 Temperature
VTT
IMON
When the shutdown bit is set to 1, the ADT7490 goes into shutdown mode.
1. This register becomes read-only when the Configuration Register 1 (0x40) Lock bit is set to 1. Any further attempts to write to this register
have no effect.
Table 88. REGISTER 0x74 − INTERRUPT MASK REGISTER 1 (POWER-ON DEFAULT = 0x00)
Bit No.
Mnemonic
R/W
Description
[0]
+2.5 VIN/
THERM
R/W
+2.5 VIN/THERM = 1 masks SMBALERT for out-of-limit conditions on the +2.5 VIN/THERM
timer channel.
[1]
VCCP
R/W
VCCP = 1 masks SMBALERT for out-of-limit conditions on the VCCP channel.
[2]
VCC
R/W
VCC = 1 masks SMBALERT for out-of-limit conditions on the VCC channel.
[3]
+5 VIN
R/W
+5 VIN = 1 masks SMBALERT for out-of-limit conditions on the +5 VIN channel.
[4]
R1T
R/W
R1T = 1 masks SMBALERT for out-of-limit conditions on the Remote 1 temperature channel.
[5]
LT
R/W
LT = 1 masks SMBALERT for out-of-limit conditions on the local temperature channel.
[6]
R2T
R/W
R2T = 1 masks SMBALERT for out-of-limit conditions on the Remote 2 temperature channel.
[7]
OOL
R/W
OOL = 1 masks SMBALERT assertions when the OOL status bit is set.
Note that the OOL mask bit is independent of the individual mask bits associated with
Interrupt Status Register 2. Therefore, if the intention is to mask SMBALERT assertions for
any of the Interrupt Status Register 2 bits, OOL must also be masked.
www.onsemi.com
63
ADT7490
Table 89. REGISTER 0x75 − INTERRUPT MASK REGISTER 2 (POWER-ON DEFAULT = 0x00)
Bit No.
Mnemonic
R/W
Description
[0]
+12 VIN
R/W
When Pin 21 is configured as a +12 VIN input, +12 VIN = 1 masks SMBALERT for out-of-limit
conditions on the +12 VIN channel.
[1]
OOL
R/W
OOL = 1 masks SMBALERT assertions when the OOL status bit is set.
Note that the OOL mask bit is independent of the individual mask bits in Interrupt Mask
Register 3 (0x82). Therefore, if the intention is to mask SMBALERT assertions for any of the
Interrupt Status Register 4 bits, OOL must also be masked.
[2]
FAN1
R/W
FAN1 = 1 masks SMBALERT for a Fan 1 fault.
[3]
FAN2
R/W
FAN2 = 1 masks SMBALERT for a Fan 2 fault.
[4]
FAN3
R/W
FAN3 = 1 masks SMBALERT for a Fan 3 fault.
[5]
Fan4/
THERM
R/W
If Pin 14 is configured as TACH4, Fan4/THERM = 1 masks SMBALERT for a Fan 4 fault. If
Pin 14 is configured as THERM, Fan4/THERM = 1 masks SMBALERT for an exceeded
THERM timer limit.
[6]
D1 FAULT
R/W
D1 = 1 masks SMBALERT for a diode open or short on a Remote 1 channel.
[7]
D2 FAULT
R/W
D2 = 1 masks SMBALERT for a diode open or short on a Remote 2 channel.
Table 90. REGISTER 0x76 − EXTENDED RESOLUTION REGISTER 1 (POWER-ON DEFAULT = 0x00) (Note 1)
Bit No.
Mnemonic
R/W
[1:0]
+2.5 VIN
Read-only
+2.5 VIN LSBs. Holds the 2 LSBs of the 10-bit +2.5 VIN Measurement
Description
[3:2]
VCCP
Read-only
VCCP LSBs. Holds the 2 LSBs of the 10-bit VCCP Measurement
[5:4]
VCC
Read-only
VCC LSBs. Holds the 2 LSBs of the 10-bit VCC Measurement
[7:6]
+5 VIN
Read-only
+5 VIN LSBs. Holds the 2 LSBs of the 10-bit +5 VIN Measurement
1. If this register is read, this register and the registers holding the MSB of each reading are frozen until read.
Table 91. REGISTER 0x77 − EXTENDED RESOLUTION REGISTER 2 (POWER-ON DEFAULT = 0x00) (Note 1)
Bit No.
Mnemonic
R/W
Description
[1:0]
+12 VIN
Read-only
+12 VIN LSBs. Holds the 2 LSBs of the 10-bit +12 VIN Measurement
[3:2]
TDM1
Read-only
Remote 1 Temperature LSBs. Holds the 2 LSBs of the 10-bit Remote 1 Temperature
Measurement
[5:4]
LTMP
Read-only
Local Temperature LSBs. Holds the 2 LSBs of the 10-bit Local Temperature Measurement
[7:6]
TDM2
Read-only
Remote 2 Temperature LSBs. Holds the 2 LSBs of the 10-bit Remote 2 Temperature
Measurement
1. If this register is read, this register and the registers holding the MSB of each reading are frozen until read.
www.onsemi.com
64
ADT7490
Table 92. REGISTER 0x78 − CONFIGURATION REGISTER 3 (POWER-ON DEFAULT = 0x00)
Bit No.
Mnemonic
R/W (Note 1)
[0]
ALERT
Enable
R/W
ALERT = 1, Pin 10 (PWM2/SMBALERT) is configured as an SMBALERT interrupt output to
indicate out-of-limit error conditions.
ALERT = 0, Pin 10 (PWM2/SMBALERT) is configured as the PWM2 output.
[1]
THERM/
+2.5VIN
R/W
THERM = 1 enables THERM functionality on Pin 22 and Pin 14, if Pin 14 is configured as
THERM, determined by Bit 0 and Bit 1 (Pin 14 Func) of Configuration Register 4 (0x7D).
When THERM is asserted, if the fans are running and the BOOST bit is set, then the fans run
at full speed. Alternatively, THERM can be programmed so that a timer is triggered to time
how long THERM has been asserted.
THERM = 0 enables +2.5VIN measurement on Pin 22 and disables THERM. If Bits [5:7] of
Configuration Register 5 (0x7C) are set, THERM is bidirectional. If they are 0, THERM is a
timer input only.
Description
Pin 14 Func (0x7D)
THERM/+2.5 VIN (0x78)
Pin 22
Pin 14
00
01
10
11
00
01
10
11
0
0
0
0
1
1
1
1
+2.5 VIN
+2.5 VIN
+2.5 VIN
+2.5 VIN
THERM
+2.5 VIN
THERM
THERM
TACH4
TACH4
SMBALERT
N/A
TACH4
THERM
SMBALERT
N/A
[2]
BOOST
R/W
When THERM is an input and BOOST = 1, assertion of THERM causes all fans to run at the
maximum programmed duty cycle for fail−safe cooling.
[3]
FAST
R/W
FAST = 1 enables fast TACH measurements on all channels. This increases the TACH measurement rate from once per second to once every 250 ms (4x).
[4]
DC1
R/W
DC1 = 1 enables TACH measurements to be continuously made on TACH1. Fans must be
driven by dc. Setting this bit prevents pulse stretching because it is not required for dc-driven
motors.
[5]
DC2
R/W
DC2 = 1 enables TACH measurements to be continuously made on TACH2. Fans must be
driven by dc. Setting this bit prevents pulse stretching because it is not required for dc-driven
motors.
[6]
DC3
R/W
DC3 = 1 enables TACH measurements to be continuously made on TACH3. Fans must be
driven by dc. Setting this bit prevents pulse stretching because it is not required for dc-driven
motors.
[7]
DC4
R/W
DC4 = 1 enables TACH measurements to be continuously made on TACH4. Fans must be
driven by dc. Setting this bit prevents pulse stretching because it is not required for dc-driven
motors.
1. Bits [3:0] of this register become read-only when the Configuration Register 1 Lock (0x40) bit is set to 1. Any further attempts to write to
Bits [3:0] have no effect.
Table 93. REGISTER 0x79 − THERM TIMER STATUS REGISTER (POWER-ON DEFAULT = 0x00)
Bit No.
Mnemonic
R/W
Description
[0]
ASRT/
TMR0
R
This bit is set high on the assertion of the THERM input and is cleared on read. If the THERM
assertion time exceeds 45.52 ms, this bit is set and becomes the LSB of the 8-bit TMR
reading. This allows THERM assertion times from 45.52 ms to 5.82 sec to be reported back
with a resolution of 22.76 ms.
[7:1]
TMR
R
Times how long THERM input is asserted. These seven bits read 0 until the THERM
assertion time exceeds 45.52 ms.
Table 94. REGISTER 0x7A − THERM TIMER LIMIT REGISTER (POWER-ON DEFAULT = 0x00)
Bit No.
Mnemonic
R/W
[7:0]
LIMT
R/W
Description
Sets maximum THERM assertion length allowed before an interrupt is generated. This is an
8-bit limit with a resolution of 22.76 ms allowing THERM assertion limits of 45.52 ms to 5.82 sec
to be programmed. If the THERM assertion time exceeds this limit, Bit 5 (FAN4/THERM) of
Interrupt Status Register 2 (0x42) is set. If the limit value is 0x00, an interrupt is generated
immediately on the assertion of the THERM input. If THERM is configured as an output, the
THERM timer limit should be set to 0xFF to avoid unwanted alerts from being generated.
www.onsemi.com
65
ADT7490
Table 95. REGISTER 0x7B − TACH PULSES PER REVOLUTION REGISTER (POWER-ON DEFAULT = 0x55)
Bit No.
Mnemonic
R/W
[1:0]
FAN1
R/W
Description
Sets number of pulses to be counted when measuring Fan 1 speed. Can be used to
determine fan pulses per revolution for unknown fan type.
Bit Code
00
01
10
11
[3:2]
FAN2
R/W
Sets number of pulses to be counted when measuring Fan 2 speed. Can be used to
determine fan pulses per revolution for unknown fan type.
Bit Code
00
01
10
11
[5:4]
FAN3
R/W
FAN4
R/W
Pulses Counted
1
2 (Default)
3
4
Sets number of pulses to be counted when measuring Fan 3 speed. Can be used to
determine fan pulses per revolution for unknown fan type.
Bit Code
00
01
10
11
[7:6]
Pulses Counted
1
2 (Default)
3
4
Pulses Counted
1
2 (Default)
3
4
Sets number of pulses to be counted when measuring Fan 4 speed. Can be used to
determine fan pulses per revolution for unknown fan type.
Bit Code
00
01
10
11
Pulses Counted
1
2 (Default)
3
4
www.onsemi.com
66
ADT7490
Table 96. REGISTER 0x7C − CONFIGURATION REGISTER 5 (POWER-ON DEFAULT = 0x01)
Bit No.
Mnemonic
R/W (Note 1)
Description
[0]
TWOS
COMPL
R/W
TWOS COMPL = 1 sets the temperature range to the twos complement temperature range.
TWOS COMPL = 0 changes the temperature range to the Offset 64 temperature range.
When this bit is changed, the ADT7490 interprets all relevant temperature register values as
defined by this bit.
[1]
Temp Offset
R/W
Temp Offset = 0 sets offset range to −63°C to +64°C with 0.5°C resolution.
Temp Offset = 1 sets offset range to −63°C to +127°C with 1°C resolution.
These settings apply to Register 0x70, Register 0x71, and Register 0x72 (Remote 1, Internal,
and Remote 2 Temperature offset registers. Note that PECI offset is always 1°C resolution).
[3:2]
RES
R/W
Reserved.
[4]
PECI R1
THERM
Output Only
R/W
PECI R1 = 1 enables THERM assertions when the PECI temperature read is higher than the
PECI TCONTROL limit and the THERM pin is bidirectional. If THERM is configured as an
output, the THERM timer limit register (0x7A) should be set to 0xFF to avoid unwanted alerts
from being generated.
PECI R1 = 0 indicates that the THERM pin is configured as a timer input only. Can also be
disabled by writing one of the following values to the PECI TCONTROL limit register (0x3D):
Writing −64°C in Offset 64 mode.
Writing −128°C in twos complement mode.
[5]
R1 THERM
Output Only
R/W
R1 = 1 enables THERM assertions when the Remote 1 temperature read is higher than the
Remote 1 THERM limit and the THERM pin is bidirectional. If THERM is configured as an
output, the THERM timer limit (Register 0x7A) should be set to 0xFF to avoid unwanted
alerts from being generated.
R1 = 0 indicates that the THERM pin is configured as a timer input only. Can also be disabled
by writing one of the following values to the Remote 1 THERM Temp Limit register (0x6A):
Writing −64°C in Offset 64 mode.
Writing −128°C in twos complement mode.
[6]
Local
THERM
Output Only
R/W
R1 = 1 enables THERM assertions when the Local temperature read is higher than the Local
THERM limit and the THERM pin is bidirectional. If THERM is configured as an output, the
THERM timer limit (Register 0x7A) should be set to 0xFF to avoid unwanted alerts from
being generated.
R1 = 0 indicates that the THERM pin is configured as a timer input only. Can also be disabled
by writing one of the below values to the local THERM limit register (0x6B):
Writing −64°C in Offset 64 mode.
Writing −128°C in twos complement mode.
[7]
R2 THERM
Output Only
R/W
R1 = 1 enables THERM assertions when the Remote 2 temperature read is higher than the
Remote 2 THERM limit and the THERM pin is bidirectional. If THERM is configured as an
output, the THERM timer limit (Register 0x7A) should be set to 0xFF to avoid unwanted
alerts from being generated.
R1 = 0 indicates that the THERM pin is configured as a timer input only. C an also be
disabled by writing one of the below values to the Remote 2 THERM temperature limit
register (0x6C):
Writing −64°C in Offset 64 mode.
Writing −128°C in twos complement mode.
1. This register becomes read-only when the Configuration Register 1 (0x40) Lock bit is set to 1. Any further attempts to write to this register
have no effect.
www.onsemi.com
67
ADT7490
Table 97. REGISTER 0x7D − CONFIGURATION REGISTER 4 (POWER-ON DEFAULT = 0x00)
Bit No.
Mnemonic
R/W (Note 1)
[1:0]
Pin 14 Func
R/W
These bits set the functionality of Pin 14.
00 = TACH4 (Default)
01 = THERM
10 = SMBALERT
11 = Reserved
[2]
THERM
Disable
R/W
THERM Disable = 0 enables THERM overtemperature output assuming THERM is correctly
configured (0x78, 0x7C, and 0x7D).
THERM Disable = 1 disables THERM overtemperature output on all channels. THERM can
also be disabled on any channel by:
Writing −64°C to the appropriate THERM temperature limit in Offset 64 mode.
Writing −128°C to the appropriate THERM temperature limit in twos complement mode.
[3]
Max/Full on
THERM
R/W
Max/Full on THERM = 0 indicates that fans go to 100% when THERM temperature limit is
exceeded.
Max/Full on THERM = 1 indicates that fans go to maximum speed (0x38, 0x39, 0x3A) when
THERM temperature limit is exceeded.
[4]
BpAtt
+2.5 VIN
R/W
Bypass +2.5VIN attenuator. When set, the measurement scale for this channel changes from
0 V (0x00) to 2.25 V (0xFF).
[5]
BpAtt VCCP
R/W
Bypass VCCP attenuator. When set, the measurement scale for this channel changes from
0 V (0x00) to 2.25 V (0xFF).
[6]
BpAtt
+5 VIN
R/W
Bypass +5 VIN attenuator. When set, the measurement scale for this channel changes from
0 V (0x00) to 2.25 V (0xFF).
[7]
BpAtt
+12 VIN
R/W
Bypass +12 VIN attenuator. When set, the measurement scale for this channel changes from
0 V (0x00) to 2.25 V (0xFF).
Description
1. This register becomes read-only when the Configuration Register 1 (0x40) Lock bit is set to 1. Any further attempts to write to this register
have no effect.
Table 98. REGISTER 0x7E − MANUFACTURER’S TEST REGISTER 1 (POWER-ON DEFAULT = 0x00)
Bit No.
Mnemonic
R/W (Note 1)
[7:0]
Reserved
Read-only
Description
Manufacturer’s test register. These bits are reserved for manufacturer’s test purposes and
should not be written to under normal operation.
1. This register becomes read-only when the Configuration Register 1 (0x40) Lock bit is set to 1. Any further attempts to write to this register
have no effect.
Table 99. REGISTER 0x7F − MANUFACTURER’S TEST REGISTER 2 (POWER-ON DEFAULT = 0x00)
Bit No.
Mnemonic
R/W (Note 1)
[7:0]
Reserved
Read-only
Description
Manufacturer’s test register. These bits are reserved for manufacturer’s test purposes and
should not be written to under normal operation.
1. This register becomes read-only when the Configuration Register 1 (0x40) Lock bit is set to 1. Any further attempts to write to this register
have no effect.
Table 100. REGISTER 0x80 − GPIO CONFIGURATION REGISTER (POWER-ON DEFAULT = 0x00)
Bit No.
Mnemonic
R/W
Description
[1:0]
RES
Reserved
[2]
GPIO2
R/W
If GPIO2 is set to input, this register reflects the state of the pin. If GPIO2 is configured as an
output, writing to this register asserts the output high or low depending on the polarity.
[3]
GPIO1
R/W
If GPIO1 is set to input, this register reflects the state of the pin. If GPIO1 is configured as an
output, writing to this register asserts the output high or low depending on the polarity.
[4]
GPIO2 POL
R/W
GPIO2 polarity bit. Set to 0 for active low. Set to 1 for active high.
[5]
GPIO1 POL
R/W
GPIO1 polarity bit. Set to 0 for active low. Set to 1 for active high.
[6]
GPIO2 DIR
R/W
GPIO2 direction bit. Set to 1 for GPIO1 to act as an input, set to 0 for GPIO2 to act as an output.
[7]
GPIO1 DIR
R/W
GPIO1 direction bit. Set to 1 for GPIO1 to act as an input, set to 0 for GPIO1 to act as an output.
Reserved
www.onsemi.com
68
ADT7490
Table 101. REGISTER 0x81 − INTERRUPT STATUS REGISTER 4 (POWER-ON DEFAULT = 0x00)
Bit No.
Mnemonic
R/W
[2:0]
RES
Read-only
Reserved
Description
[3]
PECI1
Read-only
A Logic 1 indicates that the PECI high or low limit has been exceeded by the PECI value
from PECI Client Address 0x31. This bit is cleared on a read of the status register only if the
error condition has subsided.
[4]
PECI2
Read-only
A Logic 1 indicates that the PECI high or low limit has been exceeded by the PECI value
from PECI Client Address 0x32. This bit is cleared on a read of the status register only if the
error condition has subsided.
[5]
PECI3
Read-only
A Logic 1 indicates that the PECI high or low limit has been exceeded by the PECI value
from PECI Client Address 0x33. This bit is cleared on a read of the status register only if the
error condition has subsided.
[6]
IMON
Read-only
A Logic 1 indicates that the IMON high or low limit has been exceeded. This bit is cleared on a
read of the status register only if the error condition has subsided.
[7]
VTT
Read-only
A Logic 1 indicates that the VTT high or low limit has been exceeded. This bit is cleared on a
read of the status register only if the error condition has subsided.
Table 102. REGISTER 0x82 − INTERRUPT MASK REGISTER 3 (POWER-ON DEFAULT = 0x00) (Note 1)
Bit No.
Mnemonic
R/W
Description
[0]
PECI0
R/W
A Logic 1 masks SMBALERT assertions for out-of-limit conditions on PECI0.
[1]
DATA
R/W
A Logic 1 masks SMBALERT assertions for PECI data errors.
[2]
COMM
R/W
A Logic 1 masks SMBALERT assertions for PECI communications errors.
[3]
OVT
R/W
OVT = 1 masks SMBALERT for overtemperature THERM conditions.
[6:4]
RES
R/W
Reserved
[7]
OOL
R/W
OOL = 1 masks SMBALERT assertions when the OOL status bit is set.
Note that the OOL mask bit is independent of the individual mask bits of Interrupt Mask
Register 4 (0x83). Therefore, if the intention is to mask SMBALERT assertions for any of the
Interrupt Status Register 4 bits, OOL must also be masked.
1. If the mask bits in Register 0x82 are set, it is also necessary to set the OOL mask bit in Register 0x75 to ensure the SMBALERT output is
not asserted.
Table 103. REGISTER 0x83 − INTERRUPT MASK REGISTER 4 (POWER-ON DEFAULT = 0x00) (Note 1)
Bit No.
Mnemonic
R/W
[2:0]
RES
R/W
Reserved
Description
[3]
PECI1
R/W
A Logic 1 masks ALERT assertions for out-of-limit conditions on PECI1.
[4]
PECI2
R/W
A Logic 1 masks ALERT assertions for out-of-limit conditions on PECI2.
[5]
PECI3
R/W
A Logic 1 masks ALERT assertions for out-of-limit conditions on PECI3.
[6]
IMON
R/W
A Logic 1 masks ALERT assertions for out-of-limit conditions on IMON.
[7]
VTT
R/W
A Logic 1 masks ALERT assertions for out-of-limit conditions on VTT.
1. If the mask bits in Register 0x83 are set, it is also necessary to set the OOL mask bit in Register 0x82 to ensure the SMBALERT output is
not asserted.
Table 104. VTT, IMON LIMIT REGISTERS
Register Address
R/W (Note 1)
0x84
R/W
VTT Low Limit
0x85
R/W
IMON Low Limit
0x00
0x86
R/W
VTT High Limit
0xFF
0x87
R/W
IMON High Limit
0xFF
Description
Power-On Default
0x00
1. These registers becomes read-only when the Configuration Register 1 (0x40) Lock bit is set to 1. Any subsequent attempts to write to these
registers fail.
www.onsemi.com
69
ADT7490
Table 105. REGISTER 0x88 − PECI CONFIGURATION REGISTER 2 (POWER-ON DEFAULT = 0x00)
Bit No.
Mnemonic
R/W (Note 1)
[2:0]
RES
R/W
Reserved
[3]
DOM3
R/W
CPU domain count information. Set to 0 indicates that CPU 4 associated with the PECI3
reading has a single domain (default). Set to 1 indicates that the system CPU4 contains two
domains.
[4]
DOM2
R/W
CPU domain count information. Set to 0 indicates that CPU 3 associated with the PECI2
reading has a single domain (default). Set to 1 indicates that the system CPU3 contains two
domains.
[5]
DOM1
R/W
CPU domain count information. Set to 0 indicates that CPU 2 associated with the PECI1
reading has a single domain (default). Set to 1 indicates that the system CPU2 contains two
domains.
[7:6]
#CPU
R/W
CPU count. These bits indicate the number of CPUs in the system, which provide PECI
thermal information to the ADT7490.
00 = 1 CPU (default); indicates that PECI0 data is available from CPU 1 at Address 0x30.
01 = 2 CPUs; indicates that PECI0 data is available from CPU1 at Address 0x30 and PECI1
data is available from CPU 2 at Address 0x31.
10 = 3 CPUs; indicates that PECI0 data is available from CPU1 at Address 0x30, PECI1 data
is available from CPU 2 at Address 0x31 and PECI2 data is available from CPU 3 at
Address 0x32.
11 = 4 CPUs; indicates that PECI0 data is available from CPU1 at Address 0x30, PECI1 data
is available from CPU 2 at Address 0x31, PECI2 data is available from CPU 3 at
Address 0x32 and PECI3 data is available from CPU 4 at Address 0x33.
Description
1. This register becomes read-only when the Configuration Register 1 (0x40) Lock bit is set to 1. Any subsequent attempts to write to this
register fail.
Table 106. OPERATING POINT REGISTERS (Note 1 and 2)
Register Address
R/W (Note 3)
0x8A
R/W
PECI Operating Point Register
0xFB
0x8B
R/W
Remote 1 Operating Point Register (Default = 100°C)
0x64
0x8C
R/W
Local Temperature Operating Point Register (Default = 100°C)
0x64
0x8D
R/W
Remote 2 Operating Point Register (Default = 100°C)
0x64
Description
Power-On Default
1. These registers set the target operating point for each temperature channel when the dynamic TMIN control feature is enabled.
2. The fans being controlled are adjusted to maintain temperature about an operating point.
3. This register becomes read-only when the Configuration Register 1 (0x40) Lock bit is set to 1. Any subsequent attempts to write to this
register fail.
www.onsemi.com
70
ADT7490
Table 107. REGISTER 0x8E − DYNAMIC TMIN CONTROL REGISTER 1 (POWER-ON DEFAULT = 0x00)
Bit No.
Mnemonic
R/W (Note 1)
Description
[0]
CYR2
R/W
MSB of 3-bit Remote 2 Cycle Value. The other two bits of the code reside in Dynamic TMIN
Control Register 2 (0x8F). These three bits define the delay time between making
subsequent TMIN adjustments in the control loop in terms of the number of monitoring cycles.
The system has associated thermal time constants that need to be found to optimize the
response of fans and the control loop.
[1]
VCCPLO
R/W
VCCPLO = 1. When the power is supplied from 3.3 V STANDBY and the core voltage (VCCP)
drops below its VCCP low limit value (0x46), the following occurs:
Status Bit 1 in Status Register 1 is set.
SMBALERT is generated, if enabled.
PROCHOT monitoring is disabled.
Dynamic TMIN control is disabled.
The device is prevented from entering shutdown.
Everything is re-enabled once VCCP increases above the VCCP low limit.
[2]
PHTR1
R/W
PHTR1 = 1 copies the Remote 1 current temperature to the Remote 1 operating point
register if THERM is asserted. The operating point contains the temperature at which
THERM is asserted, allowing the system to run as quietly as possible without affecting
system performance.
PHTR1 = 0 ignores any THERM assertions on the THERM pin. The Remote 1 operating
point register reflects its programmed value.
[3]
PHTL
R/W
PHTL = 1 copies the local channel’s current temperature to the local operating point register
if THERM is asserted. The operating point contains the temperature at which THERM is
asserted. This allows the system to run as quietly as possible without affecting system
performance.
PHTL = 0 ignores any THERM assertions on the THERM pin. The local temperature
operating point register reflects its programmed value.
[4]
PHTR2
R/W
PHTR2 = 1 copies the Remote 2 current temperature to the Remote 2 operating point
register if THERM is asserted. The operating point contains the temperature at which
THERM is asserted, allowing the system to run as quietly as possible without affecting
system performance.
PHTR2 = 0 ignores any THERM assertions on the THERM pin. The Remote 2 operating
point register reflects its programmed value.
[5]
R1T
R/W
R1T = 1 enables dynamic TMIN control on the Remote 1 temperature channel. The chosen
TMIN value is dynamically adjusted based on the current temperature, operating point, and
high and low limits for this zone.
R1T = 0 disables dynamic TMIN control. The TMIN value chosen is not adjusted, and the
channel behaves as described in the section.
[6]
LT
R/W
LT = 1 enables dynamic TMIN control on the local temperature channel. The chosen TMIN
value is dynamically adjusted based on the current temperature, operating point, and high
and low limits for this zone.
LT = 0 disables dynamic TMIN control. The TMIN value chosen is not adjusted, and the
channel behaves as described in the Automatic Fan Control Overview section.
[7]
R2T
R/W
R2T = 1 enables dynamic TMIN control on the Remote 2 temperature channel. The chosen
TMIN value is dynamically adjusted based on the current temperature, operating point, and
high and low limits for this zone.
R2T = 0 disables dynamic TMIN control. The TMIN value chosen is not adjusted, and the
channel behaves as described in the Automatic Fan Control Overview section.
1. This register becomes read-only when the Configuration Register 1 (0x40) Lock bit is set to 1. Any subsequent attempts to write to this
register fail.
www.onsemi.com
71
ADT7490
Table 108. REGISTER 0x8F − DYNAMIC TMIN CONTROL REGISTER 2 (POWER-ON DEFAULT = 0x00)
Bit No.
Mnemonic
R/W (Note 1)
Description
[2:0]
CYR1
R/W
3-bit Remote 1 Cycle Value. These three bits define the delay time between making
subsequent TMIN adjustments in the control loop for the Remote 1 channel in terms of
number of monitoring cycles. The system has associated thermal time constants that need to
be found to optimize the response of fans and the control loop.
[5:3]
[7:6]
CYL
CYR2
R/W
R/W
Bit Code
Decrease Cycle
Increase Cycle
000
001
010
011
100
101
110
111
8 cycles (1 sec)
16 cycles (2 sec)
32 cycles (4 sec)
64 cycles (8 sec)
128 cycles (16 sec)
256 cycles (32 sec)
512 cycles (64 sec)
1024 cycles (128 sec)
16 cycles (2 sec)
32 cycles (4 sec)
64 cycles (8 sec)
128 cycles (16 sec)
256 cycles (32 sec)
512 cycles (64 sec)
1024 cycles (128 sec)
2048 cycles (256 sec)
3-bit Local Temperature Cycle Value. These three bits define the delay time between making
subsequent TMIN adjustments in the control loop for the local temperature channel in terms of
number of monitoring cycles. The system has associated thermal time constants that need to
be found to optimize the response of fans and the control loop.
Bit Code
Decrease Cycle
Increase Cycle
000
001
010
011
100
101
110
111
8 cycles (1 sec)
16 cycles (2 sec)
32 cycles (4 sec)
64 cycles (8 sec)
128 cycles (16 sec)
256 cycles (32 sec)
512 cycles (64 sec)
1024 cycles (128 sec)
16 cycles (2 sec)
32 cycles (4 sec)
64 cycles (8 sec)
128 cycles (16 sec)
256 cycles (32 sec)
512 cycles (64 sec)
1024 cycles (128 sec)
2048 cycles (256 sec)
2 LSBs of 3-bit Remote 2 Cycle Value. The MSB of the 3-bit code resides in the Dynamic
TMIN Control Register 1 (Register 0x8E). These three bits define the delay time between
making subsequent TMIN adjustments in the control loop for the Remote 2 channel in terms
of number of monitoring cycles. The system has associated thermal time constants that need
to be found to optimize the response of fans and the control loop.
Bit Code
Decrease Cycle
Increase Cycle
000
001
010
011
100
101
110
111
8 cycles (1 sec)
16 cycles (2 sec)
32 cycles (4 sec)
64 cycles (8 sec)
128 cycles (16 sec)
256 cycles (32 sec)
512 cycles (64 sec)
1024 cycles (128 sec)
16 cycles (2 sec)
32 cycles (4 sec)
64 cycles (8 sec)
128 cycles (16 sec)
256 cycles (32 sec)
512 cycles (64 sec)
1024 cycles (128 sec)
2048 cycles (256 sec)
1. This register becomes read-only when the Configuration Register 1 (0x40) Lock bit is set to 1. Any subsequent attempts to write to this
register fail.
www.onsemi.com
72
ADT7490
Table 109. REGISTER 0x90 − DYNAMIC TMIN CONTROL REGISTER 3 (POWER-ON DEFAULT = 0x00)
Bit No.
Mnemonic
R/W (Note 1)
[2:0]
RES
Reserved
[5:3]
CYP
R/W
Description
Reserved
3-bit PECI Temperature Cycle Value. These three bits define the delay time between making
subsequent TMIN adjustments in the control loop for the PECI temperature channels in terms
of number of monitoring cycles. The system has associated thermal time constants that need
to be found to optimize the response of fans and the control loop.
Bit Code
Decrease Cycle
Increase Cycle
000
001
010
011
100
101
110
111
8 cycles (1 sec)
16 cycles (2 sec)
32 cycles (4 sec)
64 cycles (8 sec)
128 cycles (16 sec)
256 cycles (32 sec)
512 cycles (64 sec)
1024 cycles (128 sec)
16 cycles (2 sec)
32 cycles (4 sec)
64 cycles (8 sec)
128 cycles (16 sec)
256 cycles (32 sec)
512 cycles (64 sec)
1024 cycles (128 sec)
2048 cycles (256 sec)
[6]
PHTP
R/W
PHTR1 = 1 copies the PECI0 current reading to the PECI operating point register if THERM
is asserted. The operating point contains the temperature at which THERM is asserted,
allowing the system to run as quietly as possible without affecting system performance.
PHTR1 = 0 ignores any THERM assertions on the THERM pin. The PECI operating point
register reflects its programmed value.
[7]
PECI
R/W
PECI = 1 enables dynamic TMIN control on the PECI temperature channel. The chosen TMIN
value is dynamically adjusted based on the current temperature, operating point, and high
and low limits for this zone.
PECI = 0 disables dynamic TMIN control. The TMIN value chosen is not adjusted and the
channel behaves as described in the Automatic Fan Control Overview section.
1. This register becomes read-only when the Configuration Register 1 (0x40) Lock bit is set to 1. Any subsequent attempts to write to this
register fail.
Table 110. REGISTER 0x94 − PECI0 TEMPERATURE OFFSET (POWER-ON DEFAULT = 0x00)
Bit No.
R/W (Note 1)
[7:0]
R/W
Description
Allows a temperature offset to be automatically applied to the PECI0 channel measurements. The
programmable offset range is from −63°C to +127°C with 1°C resolution.
1. This register becomes read-only when the Configuration Register 1 (0x40) Lock bit is set to 1. Any further attempts to write to this register
have no effect.
Table 111. REGISTER 0x95 − PECI1 TEMPERATURE OFFSET (POWER-ON DEFAULT = 0x00)
Bit No.
R/W (Note 1)
[7:0]
R/W
Description
Allows a temperature offset to be automatically applied to the PECI1 channel measurements. The
programmable offset range is from −63°C to +127°C with 1°C resolution.
1. This register becomes read-only when the Configuration Register 1 (0x40) Lock bit is set to 1. Any further attempts to write to this register
have no effect.
Table 112. REGISTER 0x96 − PECI2 TEMPERATURE OFFSET (POWER-ON DEFAULT = 0x00)
Bit No.
R/W (Note 1)
[7:0]
R/W
Description
Allows a temperature offset to be automatically applied to the PECI2 channel measurements. The
programmable offset range is from −63°C to +127°C with 1°C resolution.
1. This register becomes read-only when the Configuration Register 1 (0x40) Lock bit is set to 1. Any further attempts to write to this register
have no effect.
Table 113. REGISTER 0x97 − PECI3 TEMPERATURE OFFSET (POWER-ON DEFAULT = 0x00)
Bit No.
R/W (Note 1)
[7:0]
R/W
Description
Allows a temperature offset to be automatically applied to the PECI3 channel measurements. The
programmable offset range is from −63°C to +127°C with 1°C resolution.
1. This register becomes read-only when the Configuration Register 1 (0x40) Lock bit is set to 1. Any further attempts to write to this register
have no effect.
www.onsemi.com
73
ADT7490
Table 114. ORDERING INFORMATION
Device Order Number*
ADT7490ARQZ−REEL
Package Type
Package Option
Shipping†
24-lead QSOP
RQ−24
2,500 Tape & Reel
†For information on tape and reel specifications, including part orientation and tape sizes, please refer to our Tape and Reel Packaging
Specifications Brochure, BRD8011/D.
*This is a Pb-Free package.
www.onsemi.com
74
ADT7490
PACKAGE DIMENSIONS
QSOP24 NB
CASE 492B
ISSUE A
2X
NOTES:
1. DIMENSIONING AND TOLERANCING PER ASME
Y14.5M, 1994.
2. CONTROLLING DIMENSION: MILLIMETERS.
3. DIMENSION b DOES NOT INCLUDE DAMBAR
PROTRUSION.
4. DIMENSION D DOES NOT INCLUDE MOLD FLASH,
PROTRUSIONS, OR GATE BURRS. MOLD FLASH,
PROTRUSIONS, OR GATE BURRS SHALL NOT EX­
CEED 0.15 PER SIDE. DIMENSION E1 DOES NOT
INCLUDE INTERLEAD FLASH OR PROTRUSION. IN­
TERLEAD FLASH OR PROTRUSION SHALL NOT EX­
CEED 0.15 PER SIDE. D AND E1 ARE DETERMINED
AT DATUM H.
5. DATUMS A AND B ARE DETERMINED AT DATUM H.
0.20 C D
D
24
A
D
C
13
GAUGE
PLANE
L2
E
E1
C
L
DETAIL A
2X
2X 12 TIPS
0.20 C D
1
e
12
24X
B
b
0.25
0.25 C D
M
C A-B D
h x 45 _
A
0.10 C
0.10 C
A1
24X
C
DIM
A
A1
b
C
D
E
E1
e
h
L
L2
M
H
SEATING
PLANE
DETAIL A
M
MILLIMETERS
MIN
MAX
1.35
1.75
0.10
0.25
0.20
0.30
0.19
0.25
8.65 BSC
6.00 BSC
3.90 BSC
0.635 BSC
0.22
0.50
0.40
1.27
0.25 BSC
0_
8_
SOLDERING FOOTPRINT*
24X
24X
0.42
1.12
24
13
6.40
1
12
0.635
PITCH
DIMENSIONS: MILLIMETERS
*For additional information on our Pb−Free strategy and soldering
details, please download the ON Semiconductor Soldering and
Mounting Techniques Reference Manual, SOLDERRM/D.
Pentium is a registered trademark of Intel Corporation.
ON Semiconductor and the
are registered trademarks of Semiconductor Components Industries, LLC (SCILLC) or its subsidiaries in the United States and/or other countries.
SCILLC owns the rights to a number of patents, trademarks, copyrights, trade secrets, and other intellectual property. A listing of SCILLC’s product/patent coverage may be accessed
at www.onsemi.com/site/pdf/Patent−Marking.pdf. SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation
or guarantee regarding the suitability of its products for any particular purpose, nor does SCILLC assume any liability arising out of the application or use of any product or circuit, and
specifically disclaims any and all liability, including without limitation special, consequential or incidental damages. “Typical” parameters which may be provided in SCILLC data sheets
and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each
customer application by customer’s technical experts. SCILLC does not convey any license under its patent rights nor the rights of others. SCILLC products are not designed, intended,
or authorized for use as components in systems intended for surgical implant into the body, or other applications intended to support or sustain life, or for any other application in which
the failure of the SCILLC product could create a situation where personal injury or death may occur. Should Buyer purchase or use SCILLC products for any such unintended or
unauthorized application, Buyer shall indemnify and hold SCILLC and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and
expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized use, even if such claim
alleges that SCILLC was negligent regarding the design or manufacture of the part. SCILLC is an Equal Opportunity/Affirmative Action Employer. This literature is subject to all applicable
copyright laws and is not for resale in any manner.
PUBLICATION ORDERING INFORMATION
LITERATURE FULFILLMENT:
Literature Distribution Center for ON Semiconductor
19521 E. 32nd Pkwy, Aurora, Colorado 80011 USA
Phone: 303−675−2175 or 800−344−3860 Toll Free USA/Canada
Fax: 303−675−2176 or 800−344−3867 Toll Free USA/Canada
Email: [email protected]
N. American Technical Support: 800−282−9855 Toll Free
USA/Canada
Europe, Middle East and Africa Technical Support:
Phone: 421 33 790 2910
Japan Customer Focus Center
Phone: 81−3−5817−1050
www.onsemi.com
75
ON Semiconductor Website: www.onsemi.com
Order Literature: http://www.onsemi.com/orderlit
For additional information, please contact your local
Sales Representative
ADT7490/D