ADT7473 Remote Thermal Monitor and Fan Control The ADT7473/ADT7473−1 controller is a thermal monitor and multiple PWM fan controller for noise sensitive or power sensitive applications requiring active system cooling. The ADT7473/ADT7473−1 can drive a fan using either a low or high frequency drive signal, monitor the temperature of up to two remote sensor diodes plus its own internal temperature, and measure and control the speed of up to four fans so they operate at the lowest possible speed for minimum acoustic noise. The automatic fan speed control loop optimizes fan speed for a given temperature. A unique dynamic TMIN control mode enables the system thermals/acoustics to be intelligently managed. The effectiveness of the system’s thermal solution can be monitored using the THERM input. The ADT7473/ADT7473−1 also provide critical thermal protection to the system using the bidirectional THERM pin as an output to prevent system or component overheating. Features • • • • • • • • • • • • • • • Controls and Monitors Up to 4 Fans High and Low Frequency Fan Drive Signal 1 On-Chip and 2 Remote Temperature Sensors Series Resistance Cancellation on the Remote Channel Extended Temperature Measurement Range, Up to 191°C Dynamic TMIN Control Mode Intelligently Optimizes System Acoustics Automatic Fan Speed Control Mode Controls System Cooling Based on Measured Temperature Enhanced Acoustic Mode Dramatically Reduces User Perception of Changing Fan Speeds Thermal Protection Feature via THERM Output Monitors Performance Impact of Intel® Pentium® 4 Processor Thermal Control Circuit via THERM Input 3-wire and 4-wire Fan Speed Measurement Limit Comparison of All Monitored Values Meets SMBus 2.0 Electrical Specifications (Fully SMBus 1.1 Compliant) These Devices are Pb-Free, Halogen Free/BFR Free and are RoHS Compliant www.onsemi.com QSOP−16 CASE 492 PIN ASSIGNMENTS SCL 1 16 SDA GND 2 15 PWM1/XTO VCC 3 14 VCCP TACH3 PWM2/ SMBALERT TACH1 4 13 D1+ 12 D1− 6 11 D2+ TACH2 7 10 D2− PWM3 8 9 SCL 1 16 SDA GND 2 15 PWM1/XTO VCC TACH3/ ADDR SELECT PWM2/ THERM_LATCH TACH1 3 14 VCCP 4 13 D1+ 12 D1− 6 11 D2+ TACH2 7 10 D2− PWM3/ ADDREN 8 9 5 5 ADT7473 (Top View) ADT7473−1 (Top View) TACH4/GPIO/ THERM/ SMBALERT TACH4/GPIO/ THERM/ SMBALERT MARKING DIAGRAMS ADT747 3ARQZ #YYWW ADT 7473−1 ARQZ #YYWW ADT7473 ADT7473−1 ADT7473ARQZ ADT7473−1ARQZ # YYWW = Specific Device Code = Specific Device Code = Pb-Free Package = Date Code ORDERING INFORMATION See detailed ordering and shipping information in the package dimensions section on page 72 of this data sheet. © Semiconductor Components Industries, LLC, 2015 April, 2015 − Rev. 10 1 Publication Order Number: ADT7473/D ADT7473 *ADDREN *ADDR SELECT SCL SDA SMBALERT ADT7473/ADT7473−1 SMBus ADDRESS SELECTION PWM1 PWM REGISTERS AND CONTROLLERS (HF & LF) PWM2 PWM3 ACOUSTIC ENHANCEMENT CONTROL SERIAL BUS INTERFACE AUTOMATIC FAN SPEED CONTROL ADDRESS POINTER REGISTER DYNAMIC TMIN CONTROL TACH1 TACH2 PWM CONFIGURATION REGISTERS FAN SPEED COUNTER TACH3 INTERRUPT MASKING TACH4 PERFORMANCE MONITORING *THERM_LATCH VCC to ADT7473/ADT7473−1 THERMAL PROTECTION INTERRUPT STATUS REGISTERS VCC D1+ D1− D2+ INPUT SIGNAL CONDITIONING AND ANALOG MULTIPLEXER SRC D2− VCCP LIMIT COMPARATORS 10-BIT ADC VALUE AND LIMIT REGISTERS BAND GAP REFERENCE BAND GAP TEMP. SENSOR * PIN FUNCTION OLNY AVAILABLE ON THE ADT7473−1 GND Figure 1. Functional Block Diagram Table 1. ABSOLUTE MAXIMUM RATINGS Parameter Rating Unit 3.6 V −0.3 to +3.6 V Input Current at any Pin ±5.0 mA Package Input Current ±20 mA 150 °C −65 to +150 °C Positive Supply Voltage (VCC) Voltage on any Input or Output Pin Maximum Junction Temperature (TJ MAX) Storage Temperature Range °C Lead Temperature, Soldering IR Reflow Peak Temperature Lead Temperature (Soldering, 10 sec) 260 300 ESD Rating 1,500 V Stresses exceeding those listed in the Maximum Ratings table may damage the device. If any of these limits are exceeded, device functionality should not be assumed, damage may occur and reliability may be affected. NOTE: This device is ESD sensitive. Use standard ESD precautions when handling. www.onsemi.com 2 ADT7473 Table 2. THERMAL CHARACTERISTICS Package Type 16-lead QSOP NOTE: qJA qJC Unit 150 39 °C/W qJA is specified for the worst-case conditions, that is, a device soldered in a circuit board for surface-mount packages. Table 3. PIN ASSIGNMENT Pin No. Mnemonic 1 SCL Digital Input (Open Drain). SMBus serial clock input. Requires SMBus pullup. 2 GND Ground Pin. 3 VCC Power Supply. Powered by 3.3 V. 4 TACH3 ADDR SELECT 5 PWM2 SMBALERT THERM_LATCH Description Digital Input (Open Drain). Fan tachometer input to measure speed of Fan 3. If in address select mode, the logic state of this pin defines the SMBus device address. Digital Output (Open Drain). ADT7473 default pin function is PWM2. Requires 10 kW typical pullup. Pulse-width modulated output to control Fan 2 speed. Can be configured as a high or low frequency drive. On the ADT7473, this pin can be reconfigured as an SMBALERT interrupt output to signal out-of-limit conditions. ADT7473−1 default pin function. THERM_LATCH is a thermal event alert signal when an overtemperature condition occurs. 6 TACH1 Digital Input (Open Drain). Fan tachometer input to measure speed of Fan 1. 7 TACH2 Digital Input (Open Drain). Fan tachometer input to measure speed of Fan 2. 8 PWM3 Digital I/O (Open Drain). Pulse-width modulated output to control the speed of Fan 3 and Fan 4. Requires 10 kW typical pullup. Can be configured as a high or low frequency drive. If pulled low on powerup, the ADT7473−1 enters address select mode, and the state of Pin 4 (ADDR SELECT) determines the ADT7473−1 slave address. ADDREN 9 TACH4 GPIO THERM SMBALERT Digital Input (Open Drain). Fan tachometer input to measure speed of Fan 4. General Purpose Open Drain Digital I/O. Bidirectional THERM pin. Can be used to time and monitor assertions on the THERM input as well as to assert when an ADT7473 THERM overtemperature limit is exceeded. For example, the pin can be connected to the PROCHOT output of an IntelR PentiumR 4 processor or to the output of a trip point temperature sensor. Can be used as an output to signal overtemperature conditions. Digital Output (Open Drain). This pin can be reconfigured as an SMBALERT interrupt output to signal out-of-limit conditions. 10 D2− Cathode Connection to Second Thermal Diode. 11 D2+ Anode Connection to Second Thermal Diode. 12 D1− Cathode Connection to First Thermal Diode. 13 D1+ Anode Connection to First Thermal Diode. 14 VCCP Analog Input. Monitors processor core voltage (0 V to 3.0 V). 15 PWM1 XTO Digital Output (Open Drain). Pulse-width modulated output to control Fan 1 speed. Requires 10 kW typical pullup. Also functions as the output from the XNOR tree in XNOR test mode. 16 SDA Digital I/O (Open Drain). SMBus bidirectional serial data. Requires 10 kW typical pullup. www.onsemi.com 3 ADT7473 Table 4. ELECTRICAL CHARACTERISTICS (TA = TMIN to TMAX, VCC = VMIN to VMAX, unless otherwise noted.) (Note 1) Parameter Conditions Min Typ Max Unit 3.0 3.3 3.6 V Interface Inactive, ADC Active − 1.5 3.0 mA 0°C ≤ TA ≤ 85°C −40°C ≤ TA ≤ +125°C − − − ±0.5 − 0.25 ±1.5 ±2.5 − °C 0°C ≤ TA ≤ 85°C −40°C ≤ TA ≤ +125°C − − − ±0.5 − 0.25 ±1.5 ±2.5 − °C First Current Second Current Third Current − − − 6 36 96 − − − mA − − ±1.5 % − − ±1.0 LSB − ±0.1 − %/V Power Supply Supply Voltage Supply Current, ICC Temperature-to-Digital Converter Local Sensor Accuracy Resolution Remote Diode Sensor Accuracy Resolution Remote Sensor Source Current Analog-to-Digital Converter (Including MUX and Attentuators) Total Unadjusted Error (TUE) Differential Nonlinearity (DNL) 8 Bits Power Supply Sensitivity Conversion Time (Voltage Input) Averaging Enabled − 11 − ms Conversion Time (Local Temperature) Averaging Enabled − 12 − ms Conversion Time (Remote Temperature) Averaging Enabled − 38 − ms Total Monitoring Cycle Time Averaging Enabled Averaging Disabled − − 145 19 − − ms Input Resistance For VCCP Channel 70 120 − kW 0°C ≤ TA ≤ 70°C −40°C ≤ TA ≤ +120°C − − − − ±6.0 ±10 % − − 65,535 − − − − 109 329 5,000 10,000 − − − − RPM − − 8.0 mA Fan RPM-to-Digital Converter Accuracy Full-scale Count Nominal Input RPM Fan Count = 0xBFFF Fan Count = 0x3FFF Fan Count = 0x0438 Fan Count = 0x021C Open-Drain Digital Outputs, PWM1 to PWM3, XTO Current Sink, IOL Output Low Voltage, VOL IOUT = −8.0 mA − − 0.4 V High Level Output Current, IOH VOUT = VCC − 0.1 20 mA Open-Drain Serial Data Bus Output (SDA) Output Low Voltage, VOL IOUT = −4.0 mA − − 0.4 V High Level Output Current, IOH VOUT = VCC − 0.1 1.0 mA Output High Voltage, VOH 0.75 × VCC − − V Output Low Voltage, VOL − − 0.4 V Input High Voltage, VIH 2.0 − − V Input Low Voltage, VIL − − 0.4 V Hysteresis − 500 − mV Digital Output Logic Levels, ADT7473−1 (THERM_LATCH) ADTL+ SMBus Digital Inputs (SCL, SDA) www.onsemi.com 4 ADT7473 Table 4. ELECTRICAL CHARACTERISTICS (TA = TMIN to TMAX, VCC = VMIN to VMAX, unless otherwise noted.) (Note 1) Parameter Conditions Min Typ Max Unit 2.0 − − − − 3.6 V Maximum Input Voltage − −0.3 − − 0.8 − V Minimum Input Voltage − 0.5 − V p-p Input High Voltage, VIH 0.75 × VCC − − V Input Low Voltage, VIL − − 0.8 V Input High Voltage, VIH − − − Digital Input Logic Levels (TACH Inputs) Input High Voltage, VIH Input Low Voltage, VIL Hysteresis Digital Input Logic Levels (THERM) ADTL+ Input Low Voltage, VIL VIN = VCC − ±1 − mA Input Low Current, IIL VIN = 0 − ±1 − mA − 5.0 − pF Clock Frequency, fSCLK 10 − 400 kHz Glitch Immunity, tSW − − 50 ns Bus Free Time, tBUF 4.7 − − ms SCL Low Time, tLOW 4.7 − − ms SCL High Time, tHIGH 4.0 − 50 ms − − 1,000 ns Input Capacitance, CIN Serial Bus Timing (Note 2) (See Figure 2) SCL, SDA Rise Time, tr SCL, SDA Fall Time, tf Data Setup Time, tSU; DAT Detect Clock Low Timeout, tTIMEOUT Can be Optionally Disabled − − 300 ms 250 − − ns 15 − 35 ms 1. All voltages are measured with respect to GND, unless otherwise noted. Typicals are at TA = 25°C and represent most likely parametric norm. Logic inputs accept input high voltages up to VMAX, even when the device is operating down to VMIN. Timing specifications are tested at logic levels of VIL = 0.8 V for a falling edge and VIH = 2.0 V for a rising edge. 2. Serial management bus (SMBus) timing specifications are guaranteed by design and are not production tested. tF t LOW t HD; STA tR SCL t HD; STA t HD; DAT t HIGH t SU; STA t SU; DAT t SU; STO SDA t BUF P S S Figure 2. Serial Bus Timing Diagram www.onsemi.com 5 P ADT7473 TYPICAL PERFORMANCE CHARACTERISTICS 0 TEMPERATURE ERROR (°C) TEMPERATURE ERROR (°C) 60 40 20 D+ To GND 0 D+ To VCC −20 −40 −60 0 10 20 30 40 50 60 70 80 −10 −20 −30 −40 −50 −60 90 100 0 2 4 6 RESISTANCE (MW) 10 12 14 16 18 20 22 CAPACITANCE (nF) Figure 3. Remote Temperature Error vs. PCB Resistance Figure 4. Temperature Error vs. Capacitance Between D+ and D− 30 70 25 100 mV 20 60 mV 15 60 TEMPERATURE ERROR (°C) TEMPERATURE ERROR (°C) 8 10 5 0 50 40 30 100 mV 20 40 mV 60 mV 10 0 40 mV −5 −10 0 100M 200M 300M 400M 500M 600M 0 100M NOISE FREQUENCY (Hz) 200M 300M 400M 500M 600M NOISE FREQUENCY (Hz) Figure 5. Remote Temperature Error vs. Common-Mode Noise Frequency Figure 6. Remote Temperature Error vs. Common-Mode Noise Frequency 1.20 15 TEMPERATURE ERROR (°C) 1.18 1.16 1.14 IDD (mA) 1.12 1.10 1.08 1.06 1.04 1.02 10 5 100 mV 0 250 mV −5 −10 1.00 0.98 3.0 −15 3.1 3.2 3.3 3.4 3.5 3.6 0 VDD (V) 100M 200M 300M 400M 500M FREQUENCY (Hz) Figure 7. Normal IDD vs. Power Supply Figure 8. Internal Temperature Error vs. Frequency www.onsemi.com 6 600M ADT7473 TYPICAL PERFORMANCE CHARACTERISTICS (Cont’d) TEMPERATURE ERROR (°C) 6 4 250 mV 2 0 −2 100 mV −4 −6 −8 −10 −12 0 100M 200M 300M 400M 500M 600M FREQUENCY (Hz) Figure 9. Remote Temperature Error vs. Power Supply Noise Frequency TEMPERATURE ERROR (°C) 3.0 2.5 2.0 1.5 1.0 0.5 0 −0.5 −1.0 −1.5 −2.0 −40 −20 0 20 40 60 85 105 125 OIL BATH TEMPERATURE (°C) Figure 10. Internal Temperature Error vs. Temperature TEMPERATURE ERROR (°C) 3.0 2.5 2.0 1.5 1.0 0.5 0 −0.5 −1.0 −1.5 −40 −20 0 20 40 60 85 105 125 OIL BATH TEMPERATURE (°C) Figure 11. Remote Temperature Error vs. Temperature www.onsemi.com 7 ADT7473 • A high frequency PWM drive can be independently Product Description The ADT7473/ADT7473−1 is a complete thermal monitor and multiple fan controller for any system requiring thermal monitoring and cooling. The device communicates with the system via a serial system management bus. The serial bus controller has a serial data line for reading and writing addresses and data (Pin 16), and an input line for the serial clock (Pin 1). All control and programming functions for the ADT7473/ADT7473−1 are performed over the serial bus. Additionally, a pin can be reconfigured as an SMBALERT output to signal out-of-limit conditions. Table 5 illustrates the differences between the ADT7473 and the ADT7473−1. • • • Table 5. ADT7473/ADT7473−1 DEVICE COMPARISON Feature ADT7473 • ADT7473−1 selected for each PWM channel on the ADT7473/ADT7473−1. This is not available on the ADT7467. The range and resolution of the temperature offset register can be changed from a ±64°C range at 0.5°C resolution to a ±128°C range at 1°C resolution. This is not available on the ADT7467. THERM overtemperature events can be disabled/enabled individually on each temperature channel. This is not available on the ADT7467. Bit 7 of Configuration Register 1 is no longer supported because the ADT7473/ADT7473−1 cannot be powered via a 5.0 V supply. Bit 0 of Configuration Register 1 (0x40) remains writable after the lock bit is set. This bit enables monitoring. 2-wire fan speed measurement is not supported on the ADT7473/ADT7473−1. Pin 5 Default: PWM2 Default: THERM_LATCH SMBus Address Fixed Address Address selectable Remote Ch. 2 Therm Limit = 100°C = 136°C Register 0x30, 0x31, 0x32 Default: 0x00 Default: 0xFF Register 0x3F Revision Reg Default: 0x68 Default: 0x69 Register 0x40, Bit 7 Reserved (R/W) 1 = Reset Latch (Lockable) Register 0x42, Bit 0 Reserved Registers 0x5C, 0x5D, 0x5E Default: 0x82 Register 0x7C, Bit 4 Reserved THERM Output Hysteresis Register 0x7D, Bit 4 Reserved THERM_LATCH Recommended Implementation Configuration Configuring the ADT7473 as shown in Figure 12 allows the system designer to use the following features: • Two PWM outputs for fan control of up to three fans. (The front and rear chassis fans are connected in parallel.) • Three TACH fan speed measurement inputs. • VCC measured internally through Pin 3. • CPU temperature measured using Remote 1 temperature channel. • Ambient temperature measured through Remote 2 temperature channel. • Bidirectional THERM pin. This feature allows Intel® Pentium® 4 PROCHOT monitoring and can function as an overtemperature THERM output. It can alternatively be programmed as an SMBALERT system interrupt output. • How to Set the Functionality of Pin 9 Pin 9 on the ADT7473/ADT7473−1 has four possible functions: SMBALERT, THERM, GPIO, and TACH4. The user chooses the required functionality by setting Bit 0 and Bit 1 of Configuration Register 4 (0x7D). Table 6. PIN 9 SETTINGS (Read-only) 1 = THERM Limit Latched Bit 0 Bit 1 Function 0 0 TACH4 Default: 0x62 0 1 THERM 1 0 GPIO 1 1 SMBALERT 0 = Remote Channel 2 1 = Remote Channel 1 and Remote Channel 2 Comparison Between ADT7467 and ADT7473/ADT7473−1 The following list shows some comparisons between the ADT7467 and the ADT7473/ADT7473−1: • The ADT7473/ADT7473−1 can be powered via a 3.3 V supply only, and does not support 5.0 V operation, while the ADT7467 does. Violating this specification results in irreversible damage to the ADT7473/ADT7473−1. See the Specifications section for more information. www.onsemi.com 8 ADT7473 CPU FAN ADT7473 PWM1 TACH2 TACH1 FRONT CHASSIS FAN REAR CHASSIS FAN PWM3 D2+ TACH3 D2− THERM CPU PROCHOT D1+ AMBIENT TEMPERATURE SDA D1− SCL SMBALERT GND ICH Figure 12. ADT7473 Configuration VCC Serial Bus Interface On PCs and servers, control of the ADT7473/ADT7473−1 is carried out using the SMBus. The ADT7473/ADT7473−1 is connected to this bus as a slave device, under the control of a master controller, which is usually (but not necessarily) the ICH. The ADT7473 has a fixed 7-bit serial bus address of 0101110 or 0x2E. The read/write bit must be added to get the 8-bit address (01011100 or 0x5C). When the ADT7473−1 is powered up with Pin 8 (PWM3/ADDREN) high, the ADT7473−1 has a default SMBus address of 0101110 or 0x2E. If more than one ADT7473−1 is used in a system, each ADT7473−1 is placed in ADDR SELECT mode by strapping Pin 8 low on powerup. The logic state of Pin 4 then determines the device’s SMBus address. The logic of these pins is sampled on powerup. The device address is sampled on powerup and latched on the first valid SMBus transaction, more precisely on the low-to-high transition at the beginning of the eighth SCL pulse, when the serial bus address byte matches the selected slave address. The selected slave address is chosen using the ADDREN pin/ADDR SELECT pin. Any attempted change in the address has no effect after this. ADT7473−1 ADDR SELECT PWM3/ ADDREN ADT7473−1 ADDR SELECT PWM3/ ADDREN 0 Low (10 kW to GND) 0101100 (0x2C) 0 High (10 kW Pullup) 0101101 (0x2D) 1 Don’t Care 0101110 (0x2E) 4 10 kW 8 ADDRESS = 0x2C Figure 14. SMBus Address = 0x2C (Pin 4 = 0) VCC ADT7473−1 PWM3/ ADDR_EN Address 8 Figure 13. Default SMBus Address = 0x2E ADDR SELECT Pin 14 State 10 kW ADDRESS = 0x2E Table 7. HARDWIRING THE ADT7473−1 SMBUS DEVICE ADDRESS Pin 13 State 4 10 kW 4 8 ADDRESS = 0x2D Figure 15. SMBus Address = 0x2D (Pin 4 = 1) www.onsemi.com 9 ADT7473 data from it, the address pointer register must be set so the correct data register is addressed, and then data can be written into that register or read from it. The first byte of a write operation always contains an address that is stored in the address pointer register. If data is written to the device, the write operation contains a second data byte that is written to the register selected by the address pointer register. This write operation is shown in Figure 17. The device address is sent over the bus, and then R/W is set to 0. This is followed by two data bytes. The first data byte is the address of the internal data register to be written to, which is stored in the address pointer register. The second data byte is the data to be written to the internal data register. When reading data from a register, there are two possibilities: 1. If the ADT7473/ADT7473−1’s address pointer register value is unknown or not the desired value, it must first be set to the correct value before data can be read from the desired data register. This is done by performing a write to the ADT7473/ADT7473−1, but only the data byte containing the register address is sent, because no data is written to the register. This is shown in Figure 18. A read operation is then performed consisting of the serial bus address, R/W bit set to 1, followed by the data byte read from the data register. This is shown in Figure 19. 2. If the address pointer register is known to be already at the desired address, data can be read from the corresponding data register without first writing to the address pointer register, as shown in Figure 19. VCC ADT7473−1 ADDR SELECT PWM3/ ADDREN 10 kW 4 8 NC DO NOT LEAVE ADDREN UNCONNECTED! CAN CAUSE UNPREDICTABLE ADDRESSES. CARE SHOULD BE TAKEN TO ENSURE THAT PIN 8 (PWM3/ADDREN) IS EITHER TIED HIGH OR LOW. LEAVING PIN 8 FLOATING COULD CAUSE THE ADT7473−1 TO POWER UP WITH AN UNEXPECTED ADDRESS. NOTE THAT IF THE ADT7473−1 IS PLACED INTO ADDR SELECT MODE, PINS 8 AND 4 CAN BE USED AS THE ALTERNATE FUNCTIONS (PWM3, TACH4/THERM) UNLESS THE CORRECT CIRCUIT IS MUXED IN AT THE CORRECT TIME OR DESIGNED TO HANDLE THESE DUAL FUNCTIONS. Figure 16. Unpredictable SMBus Address if Pin 8 is Unconnected The ability to make hardwired changes to the SMBus slave address allows the user to avoid conflicts with other devices sharing the same serial bus, for example, if more than one ADT7473−1 is used in a system. Data is sent over the serial bus in sequences of nine clock pulses: eight bits of data followed by an acknowledge bit from the slave device. Transitions on the data line must occur during the low period of the clock signal and remain stable during the high period because a low-to-high transition when the clock is high might be interpreted as a stop signal. The number of data bytes that can be transmitted over the serial bus in a single read or write operation is limited only by what the master and slave devices can handle. When all data bytes have been read or written, stop conditions are established. In write mode, the master pulls the data line high during the tenth clock pulse to assert a stop condition. In read mode, the master device overrides the acknowledge bit by pulling the data line high during the low period before the ninth clock pulse; this is known as No Acknowledge. The master takes the data line low during the low period before the tenth clock pulse, and then high during the tenth clock pulse to assert a stop condition. Any number of bytes of data can be transferred over the serial bus in one operation, but it is not possible to mix read and write in one operation, because the type of operation is determined at the beginning and cannot subsequently be changed without starting a new operation. In the ADT7473/ADT7473−1, write operations contain either one or two bytes, and read operations contain one byte. To write data to one of the device data registers or read It is possible to read a data byte from a data register without first writing to the address pointer register, if the address pointer register is already at the correct value. However, it is not possible to write data to a register without writing to the address pointer register, because the first data byte of a write is always written to the address pointer register. In addition to supporting the send byte and receive byte protocols, the ADT7473/ADT7473−1 also supports the read byte protocol. (See System Management Bus (SMBus) Specifications Version 2 for more information; this document is available from Intel.) If several read or write operations must be performed in succession, the master can send a repeat start condition instead of a stop condition to begin a new operation. www.onsemi.com 10 ADT7473 1 9 9 1 SCL 0 SDA 1 0 1 1 0 1 R/W D7 D6 D5 D4 D3 D2 D1 D0 ACK. BY ACK. BY ADT7473/ADT7473−1 ADT7473/ADT7473−1 FRAME 1 FRAME 2 SERIAL BUS ADDRESS BYTE ADDRESS POINTER REGISTER BYTE START BY MASTER 1 9 SCL (CONTINUED) SDA (CONTINUED) D7 D6 D5 D4 D3 D2 D1 D0 ACK. BY STOP BY FRAME 3 ADT7473/ADT7473−1 MASTER DATA BYTE Figure 17. Writing a Register Address to the Address Pointer Register, then Writing Data to the Selected Register 1 9 9 1 SCL SDA 0 1 0 1 1 1 0 D7 R/W D6 D5 D4 D3 D2 D1 D0 ACK. BY ACK. BY ADT7473/ADT7473−1 FRAME 1 FRAME 2 ADT7473/ADT7473−1 SERIAL BUS ADDRESS BYTE ADDRESS POINTER REGISTER BYTE START BY MASTER STOP BY MASTER Figure 18. Writing to the Address Pointer Register Only 9 1 1 9 SCL SDA 0 START BY MASTER 1 0 1 1 1 0 D7 D6 D5 D4 D3 D2 D1 D0 R/W ACK. BY NO ACK. BY STOP BY ADT7473/ADT7473−1 MASTER MASTER FRAME 2 FRAME 1 SERIAL BUS ADDRESS BYTE DATA BYTE FROM ADT7473 Figure 19. Reading Data from a Previously Selected Register Write Operations 4. The master sends a command code. 5. The slave asserts ACK on SDA. 6. The master asserts a stop condition on SDA and the transaction ends. The SMBus specification defines several protocols for various read and write operations. The ADT7473/ ADT7473−1 uses the following SMBus write protocols. The following abbreviations are used in the diagrams: S − Start P − Stop R − Read W − Write A − Acknowledge A − No Acknowledge For the ADT7473/ADT7473−1, the send byte protocol is used to write a register address to RAM for a subsequent single-byte read from the same address. This operation is illustrated in Figure 20. 1 2 3 SLAVE S W A ADDRESS Send Byte 4 5 6 REGISTER ADDRESS A P Figure 20. Setting a Register Address for Subsequent Read In this operation, the master device sends a single command byte to a slave device, as follows: 1. The master device asserts a start condition on SDA. 2. The master sends the 7-bit slave address followed by the write bit (active low). 3. The addressed slave device asserts ACK on SDA. If the master is required to read data from the register immediately after setting up the address, it can assert a repeat start condition immediately after the final ACK and carry out a single-byte read without asserting an intermediate stop condition. www.onsemi.com 11 ADT7473 Write Byte connected to a common SMBALERT line connected to the master. If a device’s SMBALERT line goes low, the following events occur: • SMBALERT is pulled low. • The master initiates a read operation and sends the alert response address (ARA = 0001 100). This is a general call address that must not be used as a specific device address. • The device whose SMBALERT output is low responds to the alert response address, and the master reads its device address. The address of the device is now known and can be interrogated in the usual way. • If more than one device’s SMBALERT output is low, the one with the lowest device address has priority in accordance with normal SMBus arbitration. In this operation, the master device sends a command byte and one data byte to the slave device, as follows: 1. The master device asserts a start condition on SDA. 2. The master sends the 7-bit slave address followed by the write bit (active low). 3. The addressed slave device asserts ACK on SDA. 4. The master sends a command code. 5. The slave asserts ACK on SDA. 6. The master sends a data byte. 7. The slave asserts ACK on SDA. 8. The master asserts a stop condition on SDA, and the transaction ends. The single byte write operation is illustrated in Figure 21. 1 2 3 SLAVE S ADDRESS W A 4 5 REGISTER ADDRESS A 6 7 8 DATA A P Once the ADT7473/ADT7473−1 has responded to the alert response address, the master must read the status registers, and the SMBALERT is cleared only if the error condition is gone. Figure 21. Single-byte Write to a Register Read Operations SMBus Timeout The ADT7473/ADT7473−1 uses the following SMBus read protocols. The ADT7473/ADT7473−1 includes an SMBus timeout feature. If there is no SMBus activity for 35 ms, the ADT7473/ADT7473−1 assumes the bus is locked and releases the bus. This prevents the device from locking or holding the SMBus expecting data. Some SMBus controllers cannot work with the SMBus timeout feature, so it can be disabled. Receive Byte This operation is useful when repeatedly reading a single register. The register address must have been previously set up. In this operation, the master device receives a single byte from a slave device, as follows: 1. The master device asserts a start condition on SDA. 2. The master sends the 7-bit slave address followed by the read bit (high). 3. The addressed slave device asserts ACK on SDA. 4. The master receives a data byte. 5. The master asserts NO ACK on SDA. 6. The master asserts a stop condition on SDA, and the transaction ends. Table 8. CONFIGURATION REGISTER 1 (REG. 0X40) Bit <6> TODIS 2 3 SLAVE S ADDRESS R A 4 5 6 DATA A P 0: SMBus Timeout Enabled (Default) 1: SMBus Timeout Disabled Voltage Measurement Input The ADT7473/ADT7473−1 has one external voltage measurement channel and can also measure its own supply voltage, VCC. Pin 14 can measure VCCP. The VCC supply voltage measurement is carried out through the VCC pin (Pin 3). The VCCP input can be used to monitor a chipset supply voltage in computer systems. In the ADT7473/ADT7473−1, the receive byte protocol is used to read a single byte of data from a register whose address has previously been set by a send byte or write byte operation. This operation is illustrated in Figure 22. 1 Description Analog-to-Digital Converter All analog inputs are multiplexed into the on-chip, successive approximation, analog-to-digital converter. (ADC) This has a resolution of 10 bits. The basic input range is 0 V to 2.25 V, but the input has built-in attenuators to allow measurement of VCCP without any external components. To allow for the tolerance of the supply voltage, the ADC produces an output of 3/4 full scale (768 decimal or 300 hexadecimal) for the nominal input voltage and thus has adequate headroom to deal with overvoltages. Figure 22. Single-byte Read from a Register Alert Response Address Alert response address (ARA) is a feature of SMBus devices that allows an interrupting device to identify itself to the host when multiple devices exist on the same bus. The SMBALERT output can be used as either an interrupt output or an SMBALERT. One or more outputs can be www.onsemi.com 12 ADT7473 Input Circuitry results averaged before being placed into the value register. When faster conversions are needed, setting BitĂ4 of Configuration RegisterĂ2 (0x73) turns averaging off. This effectively gives a reading 16Ătimes faster (711Ăms), but the reading may be noisier. The internal structure for the VCCP analog input is shown in Figure 23. The input circuit consists of an input protection diode, an attenuator, plus a capacitor to form a first order low-pass filter that provides the input immunity to high frequency noise. Bypass Voltage Input Attenuator 17.5 kW Setting BitĂ5 of Configuration RegisterĂ2 (0x73) removes the attenuation circuitry from the VCCP input. This allows the user to directly connect external sensors or to rescale the analog voltage measurement inputs for other applications. The input range of the ADC without the attenuators is 0ĂV to 2.25ĂV. VCCP 52.5 kW 35 pF Figure 23. Structure of Analog Inputs Single-channel ADC Conversion Table 9. VOLTAGE MEASUREMENT REGISTERS Register Description Default 0x21 VCCP Reading 0x00 0x22 VCCP Reading 0x00 Setting BitĂ6 of Configuration RegisterĂ2 (0x73) places the ADT7473/ADT7473−1 into single-channel ADC conversion mode. In this mode, the ADT7473/ADT7473−1 can be made to read a single voltage channel only. If the internal ADT7473/ADT7473−1 clock is used, the selected input is read every 711Ăms. The appropriate ADC channel is selected by writing to BitsĂ<7:5> of the TACH1 minimum high byte register (0x55). VCCP Limit Registers Associated with the VCCP measurement channel is a high and low limit register. Exceeding the programmed high or low limit causes the appropriate status bit to be set. Exceeding either limit can also generate SMBALERT interrupts. Table 11. PROGRAMMING SINGLE-CHANNEL ADC MODE Bits <7:5>, Register 0x55 Table 10. VCCP LIMIT REGISTERS Register Description Default 0x46 VCCP Low Limit 0x00 0x47 VCCP High Limit 0xFF Table 13 shows the input ranges of the analog inputs and output codes of the 10-bit ADC. When the ADC is running, it samples and converts a voltage input in 711Ăms and averages 16Ăconversions to reduce noise; a measurement takes nominally 11.38Ăms. Channel Selected 001 VCCP 010 VCC 101 Remote 1 Temperature 110 Local Temperature 111 Remote 2 Temperature Table 12. CONFIGURATION REGISTER 2 (REG. 0X73) Bit Description <4> 1: Averaging Off Additional ADC Functions for Voltage Measurements <5> 1: Bypass Input Attenuators A number of other functions are available on the ADT7473/ADT7473−1 to offer the system designer increased flexibility. <6> 1: Single-channel Convert Mode TACH1 Minimum High Byte Register (0x55) Bits <7:5> select ADC channel for single-channel convert mode. Turn-off Averaging For each voltage measurement read from a value register, 16 readings have actually been made internally and the www.onsemi.com 13 ADT7473 Table 13. 10-BIT ADC OUTPUT CODE VS. VIN ADC Output VCC (3.3 VIN) (Note 1) VCCP Decimal Binary (10 Bits) <0.0042 <0.00293 0 00000000 00 0.0042 to 0.0085 0.0293 to 0.0058 1 00000000 01 0.0085 to 0.0128 0.0058 to 0.0087 2 00000000 10 0.0128 to 0.0171 0.0087 to 0.0117 3 00000000 11 0.0171 to 0.0214 0.0117 to 0.0146 4 00000001 00 0.0214 to 0.0257 0.0146 to 0.0175 5 00000001 01 0.0257 to 0.0300 0.0175 to 0.0205 6 00000001 10 0.0300 to 0.0343 0.0205 to 0.0234 7 00000001 11 0.0343 to 0.0386 0.0234 to 0.0263 8 00000010 00 − − − − 1.100 to 1.1042 0.7500 to 0.7529 256 (1/4 scale) 01000000 00 − − − − 2.200 to 2.2042 1.5000 to 1.5029 512 (1/2 scale) 10000000 00 − − − − 3.300 to 3.3042 2.2500 to 2.2529 768 (3/4 scale) 11000000 00 − − − − 4.3527 to 4.3570 2.9677 to 2.9707 1013 11111101 01 4.3570 to 4.3613 2.9707 to 2.9736 1014 11111101 10 4.3613 to 4.3656 2.9736 to 2.9765 1015 11111101 11 4.3656 to 4.3699 2.9765 to 2.9794 1016 11111110 00 4.3699 to 4.3742 2.9794 to 2.9824 1017 11111110 01 4.3742 to 4.3785 2.9824 to 2.9853 1018 11111110 10 4.3785 to 4.3828 2.9853 to 2.9882 1019 11111110 11 4.3828 to 4.3871 2.9882 to 2.9912 1020 11111111 00 4.3871 to 4.3914 2.9912 to 2.9941 1021 11111111 01 4.3914 to 4.3957 2.9941 to 2.9970 1022 11111111 10 >4.3957 >2.9970 1023 11111111 11 1. The VCC output codes listed assume that VCC is 3.3 V. www.onsemi.com 14 ADT7473 DV BE + kTńq Temperature Measurement Method A simple method of measuring temperature is to exploit the negative temperature coefficient of a diode, measuring the base-emitter voltage (VBE) of a transistor operated at constant current. Unfortunately, this technique requires calibration to null out the effect of the absolute value of VBE, which varies from device to device. The technique used in the ADT7473/ADT7473−1 measures the change in VBE when the device is operated at three different currents. Previous devices have used only two operating currents, but the use of a third current allows automatic cancellation of resistances in series with the external temperature sensor. Figure 24 shows the input signal conditioning used to measure the output of an external temperature sensor. This figure shows the external sensor as a substrate transistor, but it could equally be a discrete transistor. If a discrete transistor is used, the collector is not grounded and should be linked to the base. To prevent ground noise from interfering with the measurement, the more negative terminal of the sensor is not referenced to ground, but is biased above ground by an internal diode at the D− input. C1 can optionally be added as a noise filter (recommended maximum value 1,000 pF). However, a better option in noisy environments is to add a filter, as described in the Noise Filtering section. ln(N) (eq. 1) where: k is Boltzmann’s constant. T is the absolute temperature in Kelvin. q is the charge on the carrier. N is the ratio of the two currents. Figure 24 shows the input signal conditioning used to measure the output of a remote temperature sensor. This figure shows the external sensor as a substrate transistor, provided for temperature monitoring on some microprocessors. It could also be a discrete transistor such as a 2N3904/2N3906. Table 14. TWOS COMPLEMENT TEMPERATURE DATA FORMAT Temperature Local Temperature Measurement The ADT7473/ADT7473−1 contains an on-chip band gap temperature sensor whose output is digitized by the on-chip 10-bit ADC. The 8-bit MSB temperature data is stored in the local temperature register (0x26). Because both positive and negative temperatures can be measured, the temperature data is stored in Offset 64 format or twos complement format, as shown in Table 14 and Table 15. Theoretically, the temperature sensor and ADC can measure temperatures from −63°C to +127°C (or −63°C to +191°C in the extended temperature range) with a resolution of +0.25°C. However, this exceeds the operating temperature range of the device, so local temperature measurements outside the ADT7473/ADT7473−1 operating temperature range are not possible. Digital Output (10-bit) (Note 1) –128°C 1000 0000 00 (Diode Fault) –63°C 1100 0001 00 –50°C 1100 1110 00 –25°C 1110 0111 00 –10°C 1111 0110 00 0°C 0000 0000 00 10.25°C 0000 1010 01 25.5°C 0001 1001 10 50.75°C 0011 0010 11 75°C 0100 1011 00 100°C 0110 0100 00 125°C 0111 1101 00 127°C 0111 1111 00 1. Bold numbers denote 2 LSBs of measurement in the Extended Resolution Register 2 (Register 0x77) with 0.25°C resolution. Table 15. EXTENDED RANGE, TEMPERATURE DATA FORMAT Temperature Digital Output (10-bit) (Note 1) –64°C 0000 0000 00 (Diode Fault) –63°C 0000 0001 00 –1°C 0011 1111 00 0°C 0100 0000 00 Remote Temperature Measurement 1°C 0100 0001 00 The ADT7473/ADT7473−1 can measure the temperature of two remote diode sensors or diode-connected transistors connected to Pin 10 and Pin 11 or to Pin 12 and Pin 13. The forward voltage of a diode or diode-connected transistor operated at a constant current exhibits a negative temperature coefficient of about −2 mV/°C. Unfortunately, the absolute value of VBE varies from device to device and individual calibration is required to null this out, so the technique is unsuitable for mass production. The technique used in the ADT7473/ADT7473−1 is to measure the change in VBE when the device is operated at three different currents. This is given by: 10°C 0100 1010 00 25°C 0101 1001 00 50°C 0111 0010 00 75°C 1000 1001 00 100°C 1010 0100 00 125°C 1011 1101 00 191°C 1111 1111 00 1. Bold numbers denote 2 LSBs of measurement in the Extended Resolution Register 2 (Register 0x77) with 0.25°C resolution. www.onsemi.com 15 ADT7473 N2 × I I N1 × I VDD IBIAS VOUT+ D+ REMOTE SENSING TRANSISTOR To ADC D− VOUT− LOW-PASS FILTER fC = 65 kHz Figure 24. Signal Conditioning for Remote Diode Temperature Sensors waveform to produce a dc voltage proportional to DVBE. The ADC digitizes this voltage, and a temperature measurement is produced. To reduce the effects of noise, digital filtering is performed by averaging the results of 16 measurement cycles. The results of remote temperature measurements are stored in 10-bit, twos complement format, as listed in Table 10. The extra resolution for the temperature measurements is held in the Extended Resolution Register 2 (0x77). This gives temperature readings with a resolution of 0.25°C. If a discrete transistor is used, the collector is not grounded and should be linked to the base. If a PNP transistor is used, the base is connected to the D– input and the emitter is connected to the D+ input. If an NPN transistor is used, the emitter is connected to the D– input and the base is connected to the D+ input. Figure 25 and Figure 26 show how to connect the ADT7473/ADT7473−1 to an NPN or PNP transistor for temperature measurement. To prevent ground noise from interfering with the measurement, the more negative terminal of the sensor is not referenced to ground, but is biased above ground by an internal diode at the D– input. Noise Filtering For temperature sensors operating in noisy environments, previous practice was to place a capacitor across the D+ pin and the D− pin to help combat the effects of noise. However, large capacitances affect the accuracy of the temperature measurement, leading to a recommended maximum capacitor value of 1,000 pF. This capacitor reduces the noise, but does not eliminate it, making use of the sensor difficult in a very noisy environment. The ADT7473/ADT7473−1 has a major advantage over other devices for eliminating the effects of noise on the external sensor. Using the series resistance cancellation feature, a filter can be constructed between the external temperature sensor and the part. The effect of any filter resistance seen in series with the remote sensor is automatically canceled from the temperature result. The construction of a filter allows the ADT7473/ ADT7473−1 and the remote temperature sensor to operate in noisy environments. Figure 27 shows a low-pass R-C filter with the following values: ADT7473/ ADT7473−1 D+ 2N3904 NPN D− Figure 25. Measuring Temperature by Using an NPN Transistor ADT7473/ ADT7473−1 D+ 2N3906 PNP D− Figure 26. Measuring Temperature by Using a PNP Transistor To measure DVBE, the operating current through the sensor is switched among three related currents. N1 × I and N2 × I are different multiples of the current I, as shown in Figure 24. The currents through the temperature diode are switched between I and N1 × I, giving DVBE1, and then between I and N2 × I, giving DVBE2. The temperature can then be calculated using the two DVBE measurements. This method can also cancel the effect of any series resistance on the temperature measurement. The resulting DVBE waveforms are passed through a 65 kHz low-pass filter to remove noise and then to a chopper-stabilized amplifier. This amplifies and rectifies the R + 100 W, C + 1 nF (eq. 1) This filtering reduces both common-mode noise and differential noise. 100 W D+ REMOTE TEMPERATURE SENSOR 100 W 1 nF Figure 27. Filter Between Remote Sensor and ADT7473/ADT7473−1 www.onsemi.com 16 D− ADT7473 Series Resistance Cancellation programmed to the offset register. It is important to note that, if more than one offset must be considered, the algebraic sum of these offsets must be programmed to the offset register. Parasitic resistance to the ADT7473/ADT7473−1 D+ and D− inputs (seen in series with the remote diode) is caused by a variety of factors including PCB track resistance and track length. This series resistance appears as a temperature offset in the remote sensor’s temperature measurement. This error typically causes a 0.5°C offset per W of parasitic resistance in series with the remote diode. The ADT7473/ADT7473−1 automatically cancels out the effect of this series resistance on the temperature reading, giving a more accurate result without the need for user characterization of this resistance. The ADT7473/ ADT7473−1 is designed to automatically cancel up to 3 kW of resistance, typically. This is transparent to the user by using an advanced temperature measurement method. This feature allows resistances to be added to the sensor path to produce a filter, allowing the part to be used in noisy environments. See the Noise Filtering section for details. If a discrete transistor is used with the ADT7473/ ADT7473−1, the best accuracy is obtained by choosing devices according to the following criteria: • Base-emitter voltage greater than 0.25 V at 6 mA, at the highest operating temperature. • Base-emitter voltage less than 0.95 V at 100 mA, at the lowest operating temperature. • Base resistance less than 100 W. • Small variation in hFE (such as 50 to 150) that indicates tight control of VBE characteristics. Transistors, such as 2N3904, 2N3906, or equivalents in SOT−23 packages, are suitable devices to use. Factors Affecting Diode Accuracy Nulling Out Temperature Errors As CPUs run faster, it becomes more difficult to avoid high frequency clocks when routing the D+/D– traces around a system board. Even when recommended layout guidelines are followed, some temperature errors can still be attributable to noise coupled onto the D+/D– lines. Constant high frequency noise usually attenuates or increases temperature measurements by a linear, constant value. The ADT7473/ADT7473−1 has temperature offset registers at Register 0x70 and Register 0x72 for the Remote 1 and Remote 2 temperature channels. By performing a one-time calibration of the system, the user can determine the offset caused by system board noise and null it out using the offset registers. The offset registers automatically add a twos complement, 8-bit reading to every temperature measurement. The LSBs add +0.5°C offset to the temperature reading so the 8-bit register effectively allows temperature offsets of up to ±64°C with a resolution of +0.5°C. This ensures that the readings in the temperature measurement registers are as accurate as possible. Remote Sensing Diode The ADT7473/ADT7473−1 is designed to work with either substrate transistors built into processors or discrete transistors. Substrate transistors are generally PNP types with the collector connected to the substrate. Discrete types can be either PNP or NPN transistors connected as a diode (base-shorted to the collector). If an NPN transistor is used, the collector and base are connected to D+ and the emitter is connected to D−. If a PNP transistor is used, the collector and base are connected to D− and the emitter is connected to D+. To reduce the error due to variations in both substrate and discrete transistors, a number of factors should be taken into consideration: • The ideality factor, nf, of the transistor is a measure of the deviation of the thermal diode from ideal behavior. The ADT7473/ADT7473−1 is trimmed for an nf value of 1.008. Use the following equation to calculate the error introduced at a temperature, T(°C), when using a transistor whose nf does not equal 1.008. Refer to the data sheet for the related CPU to obtain the nf values. DT + ǒn f * 1.008Ǔń1.008 • ǒ273.15 K ) TǓ Table 16. TEMPERATURE OFFSET REGISTERS (eq. 2) To factor this in, the user can write the DT value to the offset register. Then, the ADT7473/ADT7473−1 automatically adds it to or subtracts it from the temperature measurement. Some CPU manufacturers specify the high and low current levels of the substrate transistors. The high current level of the ADT7473/ADT7473−1, IHIGH, is 96 mA and the low level current, ILOW, is 6 mA. If the ADT7473/ADT7473−1 current levels do not match the current levels specified by the CPU manufacturer, it might be necessary to remove an offset. The CPU’s data sheet advises whether this offset needs to be removed and how to calculate it. This offset can be Register Description Default 0x70 Remote 1 Temperature Offset 0x00 (0°C) 0x71 Local Temperature Offset 0x00 (0°C) 0x72 Remote 2 Temperature Offset 0x00 (0°C) ADT7460/ADT7473/ADT7473−1 Backwards-compatible Mode By setting Bit 1 of Configuration Register 5 (0x7C), all temperature measurements are stored in the zone temperature value registers (Register 0x25, Register 0x26, and Register 0x27) in twos complement, in the range −63°C to +127°C. (The ADT7473/ADT7473−1 still makes calculations based on the Offset 64 extended range and clamps the results, if necessary.) The temperature limits www.onsemi.com 17 ADT7473 Additional ADC Functions for Temperature Measurement must be reprogrammed in twos complement. If a twos complement temperature below −63°C is entered, the temperature is clamped to −63°C. In this mode, the diode fault condition remains −128°C = 1000 0000, while in the extended temperature range (−64°C to +191°C), the fault condition is represented by −64°C = 0000 0000. A number of other functions are available on the ADT7473/ADT7473−1 to offer the system designer increased flexibility. Turn-off Averaging For each temperature measurement read from a value register, 16 readings have actually been made internally and the results averaged before being placed into the value register. Sometimes it is necessary to take a very fast measurement. Setting Bit 4 of Configuration Register 2 (0x73) turns averaging off. Table 17. TEMPERATURE MEASUREMENT REGISTERS Register Description Default 0x25 Remote 1 Temperature − 0x26 Local Temperature − 0x27 Remote 2 Temperature − 0x77 Extended Resolution 2 0x00 Table 20. CONVERSION TIME WITH AVERAGING DISABLED Channel Table 18. EXTENDED RESOLUTION TEMPERATURE MEASUREMENT REGISTER BITS Bit Mnemonic <7:6> TDM2 Measurement Time (ms) Voltage Channel 0.7 Remote 1 Temperature Description Remote 2 Temperature LSBs Remote 2 Temperature Local Temperature <5:4> LTMP Local Temperature LSBs <3:2> TDM1 Remote 1 Temperature LSBs 7 7 1.3 Table 21. CONVERSION TIME WITH AVERAGING ENABLED Temperature Measurement Limit Registers Associated with each temperature measurement channel are high and low limit registers. Exceeding the programmed high or low limit causes the appropriate status bit to be set. Exceeding either limit can also generate SMBALERT interrupts. Channel Description 0x4E Remote 1 Temperature Low Limit 0x01 0x4F Remote 1 Temperature High Limit 0x7F 0x50 Local Temperature Low Limit 0x01 0x51 Local Temperature High Limit 0x7F 0x52 Remote 2 Temperature Low Limit 0x01 0x53 Remote 2 Temperature High Limit 0x7F Voltage Channel 11 Remote Temperature 39 Local Temperature 12 Single-channel ADC Conversions Table 19. TEMPERATURE MEASUREMENT LIMIT REGISTERS Register Measurement Time (ms) Setting Bit 6 of Configuration Register 2 (0x73) places the ADT7473/ADT7473−1 into single-channel ADC conversion mode. In this mode, the ADT7473/ADT7473−1 can be made to read a single temperature channel only. The appropriate ADC channel is selected by writing to Bits <7:5> of the TACH1 minimum high byte register (0x55). Default Table 22. PROGRAMMING SINGLE-CHANNEL ADC MODE FOR TEMPERATURES Channel Selected Bits <7:4>, Register 0x55 Reading Temperature from the ADT7473/ADT7473−1 101 Remote 1 Temperature It is important to note that the temperature can be read from the ADT7473/ADT7473−1 as an 8-bit value (with 1°C resolution) or as a 10-bit value (with 0.25°C resolution). If only 1°C resolution is required, the temperature readings can be read back at any time and in no particular order. If the 10-bit measurement is required, a 2-register read for each measurement is used. The extended resolution register (Register 0x77) should be read first. This causes all temperature reading registers to be frozen until all temperature reading registers have been read from. This prevents an MSB reading from being updated while its two LSBs are being read, and vice versa. 110 Local Temperature 111 Remote 2 Temperature Configuration Register 2 (0x73) Bit <4> = 1, Averaging Off. Bit <6> = 1, Single-channel Convert Mode. TACH1 Minimum High Byte Register (0x55) Bits <7:5> select the ADC channel for single-channel convert mode. Overtemperature Events Overtemperature events on any of the temperature channels can be detected and dealt with automatically in www.onsemi.com 18 ADT7473 automatic fan speed control mode. Register 0x6A to Register 0x6C are the THERM limits. When a temperature exceeds its THERM limit, all PWM outputs run at 100% duty cycle or the maximum PWM duty cycle (Register 0x38, Register 0x39, and Register 0x3A) if Bit 3 of Configuration Register 4 (0x7D) is set. The fans remain running at this speed until the temperature drops below THERM minus hysteresis; this can be disabled by setting the boost bit in Configuration Register 3 (0x78), Bit 2. The hysteresis value for that THERM limit is the value programmed into the hysteresis registers (Register 0x6D and Register 0x6E). The default hysteresis value is 4°C. Table 25. THERM LIMIT REGISTER Register 0x7A Description THERM Timer Limit Default 0x00 16-bit Limits The fan TACH measurements are 16-bit results. The fan TACH limits are also 16 bits, consisting of a high byte and low byte. Because fans running under speed or stalled are normally the only conditions of interest, only high limits exist for fan TACHs. Because the fan TACH period is actually being measured, exceeding the limit indicates a slow or stalled fan. THERM LIMIT Table 26. FAN LIMIT REGISTERS TEMPERATURE FANS HYSTERESIS (°C) Register 100% Figure 28. THERM Limit Operation Description Default 0x54 TACH1 Minimum Low Byte 0xFF 0x55 TACH1 Minimum High Byte 0xFF 0x56 TACH2 Minimum Low Byte 0xFF 0x57 TACH2 Minimum High Byte 0xFF 0x58 TACH3 Minimum Low Byte 0xFF Limits, Status Registers, and Interrupts 0x59 TACH3 Minimum High Byte 0xFF Limit Values 0x5A TACH4 Minimum Low Byte 0xFF Associated with each measurement channel on the ADT7473/ADT7473−1 are high and low limits. These can form the basis of system status monitoring; a status bit can be set for any out-of-limit condition and is detected by polling the device. Alternatively, SMBALERT interrupts can be generated to flag a processor or microcontroller of out-of-limit conditions. 0x5B TACH4 Minimum High Byte 0xFF Out-of-Limit Comparisons Once all limits have been programmed, the ADT7473/ ADT7473−1 can be enabled for monitoring. The ADT7473/ ADT7473−1 measures all voltage and temperature measurements in round-robin format and sets the appropriate status bit for out-of-limit conditions. TACH measurements are not part of this round-robin cycle. Comparisons are done differently depending on whether the measured value is being compared to a high or low limit. 8-bit Limits The following is a list of 8-bit limits on the ADT7473/ ADT7473−1. Table 23. VOLTAGE LIMIT REGISTERS Register Description High limit > comparison performed Low limit ≤ comparison performed Default 0x46 VCCP Low Limit 0x00 0x47 VCCP High Limit 0xFF 0x48 VCC Low Limit 0x00 0x49 VCC High Limit 0xFF Voltage and temperature channels use a window comparator for error detecting and, therefore, have high and low limits. Fan speed measurements use only a low limit. This fan limit is needed only in manual fan control mode. Analog Monitoring Cycle Time Table 24. TEMPERATURE LIMIT REGISTERS Register Description Default 0x4E Remote 1 Temperature Low Limit 0x01 0x4F Remote 1 Temperature High Limit 0xFF 0x6A Remote 1 THERM Limit 0xA4 0x50 Local Temperature Low Limit 0x01 0x51 Local Temperature High Limit 0xFF 0x6B Local THERM Temperature Limit 0xA4 0x52 Remote 2 Temperature Low Limit 0x01 0x53 Remote 2 Temperature High Limit 0xFF 0x6C Remote 2 THERM Temp. Limit 0xA4 The analog monitoring cycle begins when a 1 is written to the start bit (Bit 0) of Configuration Register 1 (0x40). By default, the ADT7473/ADT7473−1 powers up with this bit set. The ADC measures each analog input in turn and, as each measurement is completed, the result is automatically stored in the appropriate value register. This round-robin monitoring cycle continues unless disabled by writing a 0 to Bit 0 of Configuration Register 1. As the ADC is normally left to free-run in this manner, the time taken to monitor all the analog inputs is normally not of interest, because the most recently measured value of any input can be read out at any time. www.onsemi.com 19 ADT7473 For applications where the monitoring cycle time is important, it can easily be calculated. The total number of channels measured is: • One Dedicated Supply Voltage Input (VCCP) • Supply Voltage (VCC Pin) • Local Temperature • Two Remote Temperatures Table 27. INTERRUPT STATUS REGISTER 1 (REG. 0X41) As mentioned previously, the ADC performs round-robin conversions. The total monitoring cycle time for averaged voltage and temperature monitoring is 146 ms. The total monitoring cycle time for voltage and temperature monitoring with averaging disabled is 19 ms. The ADT7473/ ADT7473−1 is a derivative of the ADT7467. As a result, the total conversion time in the ADT7473/ ADT7473−1 is the same as the total conversion time of the ADT7467, even though the ADT7473/ADT7473−1 has fewer monitored channels. Fan TACH measurements are made in parallel and are not synchronized with the analog measurements in any way. Bit Mnemonic Description 7 OOL 1 denotes a bit in Interrupt Status Register 2 is set and Interrupt Status Register 2 should be read. 6 R2T 1 indicates that the Remote 2 Temperature High or Low Limit has been exceeded. 5 LT 4 R1T 1 indicates that the Local Temperature High or Low Limit has been exceeded. 1 indicates that the Remote 1 Temperature High or Low Limit has been exceeded. 3 − 2 VCC Unused 1 indicates that the VCC High or Low Limit has been exceeded. 1 VCCP 1 indicates that the VCCP High or Low Limit has been exceeded. 0 − Unused Table 28. INTERRUPT STATUS REGISTER 2 (REG. 0X42) Interrupt Status Registers The results of limit comparisons are stored in Interrupt Status Register 1 and Interrupt Status Register 2. The status register bit for each channel reflects the status of the last measurement and limit comparison on that channel. If a measurement is within limits, the corresponding status register bit is cleared to 0. If the measurement is out of limits, the corresponding status register bit is set to 1. The state of the various measurement channels can be polled by reading the status registers over the serial bus. In Bit 7 (OOL) of Interrupt Status Register 1 (Reg. 0x41), a 1 means an out-of-limit event has been flagged in Interrupt Status Register 2. This means the user needs only to read Interrupt Status Register 2 when this bit is set. Alternatively, Pin 5 or Pin 9 on the ADT7473 can be configured as an SMBALERT output, while only Pin 9 can be configured to be an SMBALERT on the ADT7473−1. This automatically notifies the system supervisor of an out-of-limit condition. Reading the status registers clears the appropriate status bit as long as the error condition that caused the interrupt has cleared. Status register bits (except OVT) are sticky. Whenever a status bit is set, indicating an out-of-limit condition, it remains set even if the event that caused it has gone away (until read). The only way to clear the status bit is to read the status register after the event has gone away. Interrupt mask registers (Register 0x74 and Register 0x75) allow individual interrupt sources to be masked from causing an SMBALERT. However, if one of these masked interrupt sources goes out of limit, its associated status bit is set in the interrupt status registers. OVT clears automatically. Bit Mnemonic 7 D2 1 indicates an open or short on D2+/D2− inputs. Description 6 D1 1 indicates an open or short on D1+/D1− inputs. 5 F4P 1 indicates that Fan 4 has dropped below the minimum speed. Alternatively, indicates that THERM timer limit has been exceeded if the THERM timer function is used. 4 FAN3 1 indicates that Fan 3 has dropped below the minimum speed. 3 FAN2 1 indicates that Fan 2 has dropped below the minimum speed. 2 FAN1 1 indicates that Fan 1 has dropped below the minimum speed. 1 OVT 1 indicates that a THERM overtemperature limit has been exceeded. 0 THERM Limit Latch 1 indicates that a Remote Channel 2 latch. SMBALERT Interrupt Behavior The ADT747/ADT7473−1 can be polled for status, or an SMBALERT interrupt can be generated for out-of-limit conditions. It is important to note how the SMBALERT output and status bits behave when writing interrupt handler software. www.onsemi.com 20 ADT7473 HIGH LIMIT HIGH LIMIT TEMPERATURE TEMPERATURE “STICKY” STATUS BIT CLEARED ON READ (TEMP BELOW LIMIT) CLEARED ON READ (TEMP BELOW LIMIT) “STICKY” STATUS BIT TEMP BACK IN LIMIT TEMP BACK IN LIMIT (STATUS BIT STAYS SET) (STATUS BIT STAYS SET) SMBALERT SMBALERT INTERRUPT MASK BIT SET Figure 29. SMBALERT and Status Bit Behavior INTERRUPT MASK BIT CLEARED (SMBALERT RE-ARMED) Figure 29 shows how the SMBALERT output and sticky status bits behave. Once a limit is exceeded, the corresponding status bit is set to 1. The interrupt status bit remains set until the error condition subsides and the interrupt status register is read. The status bits are referred to as sticky because they remain set until read by software. This ensures that an out-of-limit event cannot be missed if software is polling the device periodically. Note that the SMBALERT output remains low for the entire duration that a reading is out of limit and until the interrupt status register has been read. This has implications on how software handles the interrupt. Note that THERM overtemperature events are not sticky, resetting immediately after the overtemperature condition ceases. This also applies to SMBALERT if associated with an OVT event. Figure 30. How Masking the Interrupt Source Affects SMBALERT Output Masking Interrupt Sources Register 0x74, Interrupt Mask Register 1 Register 0x75, Interrupt Mask Register 2 These registers allow individual interrupt sources to be masked out to prevent SMBALERT interrupts. Masking an interrupt source prevents only the SMBALERT output from being asserted; the appropriate status bit is set normally. Table 29. INTERRUPT MASK REGISTER 1 (REG. 0X74) Bit Mnemonic Description To prevent the system from being tied up servicing interrupts, it is recommended to handle the SMBALERT interrupt as follows: 1. Detect the SMBALERT assertion. 2. Enter the interrupt handler. 3. Read the status registers to identify the interrupt source. 4. Mask the interrupt source by setting the appropriate mask bit in the interrupt mask registers (Register 0x74 and Register 0x75). 5. Take the appropriate action for a given interrupt source. 6. Exit the interrupt handler. 7 OOL 0 when one or more alerts are generated in Interrupt Status Register 2, assuming all the mask bits in the Interrupt Mask Register 2 (0x75) = 1; SMBALERT is still asserted. 1 when one or more alerts are generated in Interrupt Status Register 2, assuming all the mask bits in the Interrupt Mask Register 2 (0x75) = 1; SMBALERT is not asserted. 6 R2T 1 masks SMBALERT for Remote 2 temperature. 5 LT 4 R1T Periodically poll the status registers. If the interrupt status bit has cleared, reset the corresponding interrupt mask bit to 0. This causes the SMBALERT output and status bits to behave as shown in Figure 30. 3 − 2 VCC 1 masks SMBALERT for the VCC channel. 1 VCCP 1 masks SMBALERT for the VCCP channel. 0 − Handling SMBALERT Interrupts www.onsemi.com 21 1 masks SMBALERT for Local temperature. 1 masks SMBALERT for Remote 1 temperature. Unused Unused ADT7473 THERM as an Input Table 30. INTERRUPT MASK REGISTER 2 (REG. 0X75) Bit Mnemonic Description 7 D2 1 masks SMBALERT for Diode 2 errors. 6 D1 1 masks SMBALERT for Diode 1 errors. 5 FAN4 1 masks SMBALERT for Fan 4 failure. If the TACH4 pin is being used as the THERM input, this bit masks SMBALERT for a THERM event. 4 FAN3 1 masks SMBALERT for Fan 3. 3 FAN2 1 masks SMBALERT for Fan 2. 2 FAN1 1 masks SMBALERT for Fan 1. 1 OVT 1 masks SMBALERT for overtemperature (exceeding THERM limits). 0 − When THERM is configured as an input, the ADT7473/ADT7473−1 can time assertions on the THERM pin. This can be useful for connecting to the PROCHOT output of a CPU to gauge system performance. See the THERM Timer section for more information. The user can also set up the ADT7473/ADT7473−1 so that, when the THERM pin is driven low externally, the fans run at 100%. The fans run at 100% for the duration of the time the THERM pin is pulled low. This is done by setting the BOOST bit (Bit 2) in Configuration Register 3 (0x78) to 1. This works only if the fan is already running, for example, in manual mode when the current duty cycle is above 0x00, or in automatic mode when the temperature is above TMIN. If the temperature is below TMIN or if the duty cycle in manual mode is set to 0x00, then pulling the THERM low externally has no effect. See Figure 31 for more information. Unused Enabling the SMBALERT Interrupt Output The SMBALERT interrupt function is disabled by default. Pin 5 or Pin 9 can be reconfigured as an SMBALERT output to signal out-of-limit conditions. (SMBALERT function is available only on Pin 9 of ADT7473−1.) TMIN Table 31. ADT7473 CONFIGURING PIN 5 AS SMBALERT OUTPUT Register THERM Bit Setting Configuration Register 3 (Register 0x78) <0> ALERT = 1 THERM ASSERTED TO LOW AS AN INPUT. FANS DO NOT GO TO 100% BECAUSE TEMPERATURE IS BELOW TMIN THERM ASSERTED TO LOW AS AN INPUT. FANS DO NOT GO TO 100% BECAUSE TEMPERATURE IS ABOVE TMIN The ADT7473−1 THERM_LATCH function latches and asserts when temperature rises 0.25°C above the THERM limit for the selected remote channel. Due to a THERM event, the fans spin at full speed. This can be disabled by setting Bit 2 in Configuration Register 0x7D. Pin 5 remains latched until temperature falls below THERM limit for the selected zone, Remote Channel D1 or Remote Channel D2, and Bit 0 in Status Register 2 is cleared. By default on the ADT7473−1, the THERM limit is set as 136°C for Remote Channel 2 and 100°C for Remote Channel 1. Figure 31. Asserting THERM Low as an Input in Automatic Fan Speed Control Mode THERM Timer The ADT7473/ADT7473−1 has an internal timer to measure THERM assertion time. For example, the THERM input can be connected to the PROCHOT output of a Pentium® 4 CPU to measure system performance. The THERM input can also be connected to the output of a trip point temperature sensor. The timer is started on the assertion of the ADT7473/ADT7473−1 THERM input and stopped when THERM is deasserted. The timer counts THERM times cumulatively; that is, the timer resumes counting on the next THERM assertion. The THERM timer continues to accumulate THERM assertion times until the timer is read (it is cleared on read) or until it reaches full scale. If the counter reaches full scale, it stops at that reading until cleared. The 8-bit THERM timer status register (0x79) is designed so that Bit 0 is set to 1 on the first THERM assertion. Once the cumulative THERM assertion time has exceeded 45.52 ms, Bit 1 of the THERM timer is set and Bit 0 Assigning THERM Functionality to a Pin Pin 9 on the ADT7473/ADT7473−1 has four possible functions: SMBALERT, THERM, GPIO, and TACH4. The user chooses the required functionality by setting Bit 0 and Bit 1 of Configuration Register 4 (0x7D). Table 32. CONFIGURATION REGISTER 4 (REG. 0X7D) Bit 1 Bit 0 Function 0 1 TACH4 0 0 THERM 1 1 SMBusALERT 1 0 GPIO Once Pin 9 is configured as THERM, it must be enabled by setting Bit 1 of Configuration Register 3 (0x78). www.onsemi.com 22 ADT7473 becomes the LSB of the timer with a resolution of 22.76 ms (see Figure 32). When using the THERM timer, be aware of the following. After a THERM timer read (0x79): 1. The contents of the timer are cleared on read. 2. The F4P bit (Bit 5) of Interrupt Status Register 2 needs to be cleared (assuming that the THERM timer limit has been exceeded). limit register. This 8-bit register allows a limit from 0 sec (first THERM assertion) to 5.825 sec to be set before an SMBALERT is generated. The THERM timer value is compared with the contents of the THERM timer limit register. If the THERM timer value exceeds the THERM timer limit value, the F4P bit (Bit 5) of Interrupt Status Register 2 is set and an SMBALERT is generated. The F4P bit (Bit 5) of Interrupt Mask Register 2 (0x75) masks out the SMBALERT if this bit is set to 1; however, the F4P bit of Interrupt Status Register 2 still is set if the THERM timer limit is exceeded. Figure 33 is a functional block diagram of the THERM timer, limit, and associated circuitry. Writing a value of 0x00 to the THERM timer limit register (0x7A) causes an SMBALERT to be generated on the first THERM assertion. A THERM timer limit value of 0x01 generates an SMBALERT once cumulative THERM assertions exceed 45.52 ms. If the THERM timer is read during a THERM assertion, then the following happens: 1. The contents of the timer are cleared. 2. Bit 0 of the THERM timer is set to 1 (because a THERM assertion is occurring). 3. The THERM timer increments from 0. 4. If the THERM timer limit (Register 0x7A) = 0x00, the F4P bit is set. THERM Configuring the THERM Behavior THERM TIMER (REG. 0x79) 0 0 0 0 0 0 0 1 7 6 5 4 3 2 1 0 1. Configure Pin 9 as a THERM timer input. Setting Bit 1 (THERM timer enable) of Configuration Register 3 (0x78) enables the THERM timer monitoring functionality. This is disabled on Pin 9 by default. Setting Bit 0 and Bit 1 (PIN9FUNC) of Configuration Register 4 (0x7D) enables THERM timer/output functionality on Pin 9 (Bit 1 of Configuration Register 3, THERM, must also be set). Pin 9 can also be used as TACH4. Setting Bit 5, Bit 6, and Bit 7 of Configuration Register 5 (0x7C) makes THERM bidirectional. This means that if the appropriate temperature channel exceeds the THERM temperature limit, the THERM output asserts. If the ADT7473 is not pulling THERM low, but THERM is pulled low by an external device (such as a CPU overtemperature signal), the THERM timer also times THERM assertions. If Bit 5, Bit 6, and Bit 7 of Configuration Register 5 (0x7C) are set to 0, THERM is set as a timer input only. 2. Select the desired fan behavior for THERM timer events. Assuming the fans are running, setting Bit 2 (BOOST) of Configuration Register 3 (0x78) causes all fans to run at 100% duty cycle whenever THERM is asserted. This allows fail-safe system cooling. If this bit is 0, the fans run at their current settings and are not affected by THERM events. If the fans are not already running when THERM is asserted, the fans do not run at full speed. 3. Select whether THERM timer events should generate SMBALERT interrupts. Bit 5 (F4P) of Interrupt Mask Register 2 (0x75), when set, masks out the SMBALERT when the THERM timer limit value is exceeded. This bit should be cleared if SMBALERTis based on THERM events required. THERM ASSERTED ≤22.76 ms THERM ACCUMULATE THERM LOW ASSERTION TIMES THERM TIMER (REG. 0x79) 0 0 0 0 0 0 1 0 7 6 5 4 3 2 1 0 THERM ASSERTED ≥45.52 ms THERM ACCUMULATE THERM LOW ASSERTION TIMES THERM TIMER (REG. 0x79) 0 0 0 0 0 1 0 1 7 6 5 4 3 2 1 0 THERM ASSERTED ≥113.8 ms (91.04 ms + 22.76 ms) Figure 32. Understanding the THERM Timer Generating SMBALERT Interrupts from THERM Timer Events The ADT7473/ADT7473−1 can generate an SMBALERT when a programmable THERM timer limit is exceeded. This allows the system designer to ignore brief, infrequent THERM assertions, while capturing longer THERM timer events. Register 0x7A is the THERM timer www.onsemi.com 23 ADT7473 performance is degrading significantly because THERM is asserting more frequently on an hourly basis. Alternatively, OS- or BIOS-level software can timestamp when the system is powered on. If an SMBALERT is generated due to the THERM timer limit being exceeded, another timestamp can be taken. The difference in time can be calculated for a fixed THERM timer limit time. For example, if it takes one week for a THERM timer limit of 2.914 seconds to be exceeded and the next time it takes only one hour, this is an indication of a serious degradation in system performance. 4. Select a suitable THERM limit value. This value determines whether an SMBALERT is generated on the first THERM assertion, or only if a cumulative THERM assertion time limit is exceeded. A value of 0x00 causes an SMBALERT to be generated on the first THERM assertion. 5. Select a THERM monitoring time. This value specifies how often OS or BIOS level software checks the THERM timer. For example, BIOS could read the THERM timer once an hour to determine the cumulative THERM assertion time. If, for example, the total THERM assertion time is <22.76 ms in Hour 1, >182.08 ms in Hour 2, and >5.825 sec in Hour 3, this can indicate that system THERM TIMER LIMIT (REG. 0x7A) 2.914 s 1.457 s 728.32 ms 364.16 ms 182.08 ms 91.04 ms 45.52 ms 22.76 ms 2.914 s 1.457 s 728.32 ms 364.16 ms 182.08 ms 91.04 ms 45.52 ms 22.76 ms 0 1 2 3 4 5 6 7 THERM TIMER (REG. 0x79) THERM 7 6 5 4 3 2 1 0 THERM TIMER CLEARED ON READ COMPARATOR IN OUT LATCH F4P BIT (BIT 5) INTERRUPT STATUS REGISTER 2 SMBALERT RESET CLEARED ON READ 1 = MASK F4P BIT (BIT 5) INTERRUPT MASK REGISTER 2 (REG. 0x75) Figure 33. Functional Diagram of the ADT7473 THERM Monitoring Circuitry Configuring the THERM Pin as Bidirectional are exceeded by 0.25°C. The THERM temperature limit registers are at Register 0x6A, Register 0x6B, and Register 0x6C, respectively. Setting Bit 5, Bit 6, and Bit 7 of Configuration Register 5 (0x7C) makes THERM bidirectional for the Remote 1, Local, and Remote 2 temperature channels, respectively. Figure 34 shows how the THERM pin asserts low as an output in the event of a critical overtemperature. An alternative method of disabling THERM is to program the THERM temperature limit to –64°C or less in Offset 64 mode, or −128°C or less in twos complement mode; that is, for THERM temperature limit values less than –63°C or –128°C, respectively, THERM is disabled. THERM can also be disabled by setting Bit 1 of Configuration Register 3 (0x78) to 0. In addition to monitoring THERM as an input, the ADT7473/ADT7473−1 can optionally drive THERM low as an output. When PROCHOT is bidirectional, THERM can be used to throttle the processor by asserting PROCHOT. The user can preprogram system-critical thermal limits. If the temperature exceeds a thermal limit by 0.25°C, THERM asserts low. If the temperature is still above the thermal limit on the next monitoring cycle, THERM stays low. THERM remains asserted low until the temperature is equal to or below the thermal limit. Because the temperature for that channel is measured only once for every monitoring cycle after THERM asserts, it is guaranteed to remain low for at least one monitoring cycle. The THERM pin can be configured to assert low, if the Remote 1, Local, or Remote 2 THERM temperature limits www.onsemi.com 24 ADT7473 12 V 10 kW THERM LIMIT 10 kW 12 V FAN TACH TEMP 1N4148 12 V THERM LIMIT 0.255C 4.7 kW ADT7473/ ADT7473−1 THERM 3.3 V 10 kW Q1 NDT3055L PWM MONITORING CYCLE Figure 35. Driving a 3-wire Fan Using an N-channel MOSFET Figure 34. Asserting THERM as an Output, Based on Tripping THERM Limits Figure 35 uses a 10 kW pullup resistor for the TACH signal. This assumes that the TACH signal is an open-collector from the fan. In all cases, the TACH signal from the fan must be kept below 3.6 V maximum to prevent damaging the ADT7473/ADT7473−1. If uncertain as to whether the fan used has an open-collector or totem pole TACH output, use one of the input signal conditioning circuits shown in the Fan Speed Measurement section. Figure 36 shows a fan drive circuit using an NPN transistor such as a general-purpose MMBT2222. While these devices are inexpensive, they tend to have much lower current handling capabilities and higher on resistance than MOSFETs. When choosing a transistor, care should be taken to ensure that it meets the fan’s current requirements. Ensure that the base resistor is chosen so that the transistor is saturated when the fan is powered on. The ADT7473/ADT7473−1 uses pulse-width modulation (PWM) to control fan speed. This relies on varying the duty cycle (or on/off ratio) of a square wave applied to the fan to vary the fan speed. The external circuitry required to drive a fan using PWM control is extremely simple. For 4-wire fans, the PWM drive might need only a pullup resistor. In many cases, the 4-wire fan PWM input has a built-in pullup resistor. The ADT7473/ADT7473−1 PWM frequency can be set to a selection of low frequencies or a single high PWM frequency. The low frequency options are usually used for 3-wire fans, while the high frequency option is usually used with 4-wire fans. Note that care must be taken to ensure that the PWM or TACH pins are not connected to a pullup supply greater than 3.6 V. Many fans have internal pullups connected to the TACH/PWM pins to a supply greater than 3.6 V. Clamping or dividing down the voltage on these pins must be done where necessary. Clamping these pins with a Zener diode can also help prevent back-EMF related noise from being coupled into the system. For 3-wire fans, a single N-channel MOSFET is the only drive device required. The specifications of the MOSFET depend on the maximum current required by the fan being driven. Typical notebook fans draw a nominal 170 mA; therefore, SOT devices can be used where board space is a concern. In desktops, fans can typically draw 250 mA to 300 mA each. If you drive several fans in parallel from a single PWM output or drive larger server fans, the MOSFET must handle the higher current requirements. The only other stipulation is that the MOSFET have a gate voltage drive, VGS < 3.3 V, for direct interfacing to the PWM output. The MOSFET should also have a low on resistance to ensure that there is not significant voltage drop across the FET, which would reduce the voltage applied across the fan and, therefore, the maximum operating speed of the fan. Figure 35 shows how to drive a 3 wire fan using PWM control. 12 V 12 V 10 kW 10 kW TACH TACH 4.7 kW ADT7473/ ADT7473−1 12 V FAN 1N4148 Fan Drive Using PWM Control 3.3 V 665 W PWM Q1 MMBT2222 Figure 36. Driving a 3-wire Fan Using an NPN Transistor Because 4-wire fans are powered continuously, the fan speed is not switched on or off as with previous PWM driven/powered fans. This enables it to perform better than 3-wire fans, especially for high frequency applications. Figure 37 shows a typical drive circuit for 4-wire fans. As the PWM input on 4-wire fans is usually internally pulled up to a voltage greater than 3.6 V (the maximum voltage allowed on the ADT7473/ADT7473−1 PWM output), the PWM output should be clamped to 3.3 V using a Zener diode. www.onsemi.com 25 ADT7473 12 V Because the MOSFET can handle up to 3.5 A, it is simply a matter of connecting another fan directly in parallel with the first. Care should be taken in designing drive circuits with transistors and FETs to ensure the PWM pins are not required to source current and that they sink less than the 8 mA maximum current specified on the data sheet. 12 V 12 V, 4-WIRE FAN 10 kW VCC TACH PWM 10 kW TACH TACH 4.7 kW ADT7473/ ADT7473−1 Driving up to Three Fans from PWM3 TACH measurements for fans are synchronized to particular PWM channels; for example, TACH1 is synchronized to PWM1. TACH3 and TACH4 are both synchronized to PWM3, so PWM3 can drive two fans. Alternatively, PWM3 can be programmed to synchronize TACH2, TACH3, and TACH4 to the PWM3 output. This allows PWM3 to drive two or three fans. In this case, the drive circuitry looks the same, as shown in Figure 38 and Figure 39. The SYNC bit in Register 0x62 enables this function. Synchronization is not required in high frequency mode when used with 4-wire fans. PWM 3.3 V Figure 37. Driving a 4-wire Fan Driving Two Fans from PWM3 The ADT7473/ADT7473−1 has four TACH inputs available for fan speed measurement, but only three PWM drive outputs. If a fourth fan is used in the system, it should be driven from the PWM3 output in parallel with the third fan. Figure 38 shows how to drive two fans in parallel using low cost NPN transistors. Figure 39 shows the equivalent circuit using a MOSFET. Table 33. SYNC: ENHANCED ACOUSTICS REGISTER 1 (REG. 0X62) 3.3 V ADT7473/ ADT7373−1 1 kW PWM3 2.2 kW 3.3 V 1N4148 12 V TACH3 3.3 V 3.3 V Q3 MMBT2222 3.3 V 10 kW TYP ADT7473/ ADT7473−1 10 kW TYP TACH3 3.3 V 3.3 V TACH 3.3 V 5V or 12 V FAN TACH 1 Synchronizes TACH2, TACH3, and TACH4 to PWM3. VCC 12 V +V +V 1N4148 3.3 V SYNC Pin 4, Pin 6, Pin 7, and Pin 9 (when configured as TACH inputs) are open-drain TACH inputs intended for fan speed measurement. Signal conditioning in the ADT7473/ADT7473−1 accommodates the slow rise and fall times typical of fan tachometer outputs. The maximum input signal range is 0 V to 3.6 V. In the event that these inputs are supplied from fan outputs that exceed 0 V to 3.6 V, either resistive attenuation of the fan signal or diode clamping must be included to keep inputs within an acceptable range. Figure 40 to Figure 43 show circuits for most common fan TACH outputs. If the fan TACH output has a resistive pullup to VCC, it can be connected directly to the fan input, as shown in Figure 40. Figure 38. Interfacing Two Fans in Parallel to the PWM3 Output Using Low Cost NPN Transistors TACH4 <4> Description TACH Inputs Q2 MMBT2222 10 kW Mnemonic TACH4 Q1 MMBT3904 10 kW Bit PULLUP 4.7 kW TYP 5V or 12 V FAN TACH OUTPUT TACH 10 kW TYP PWM3 FAN SPEED COUNTER ADT7473/ ADT7473−1 Q1 NDT3055L Figure 40. Fan with TACH Pullup to VCC Figure 39. Interfacing Two Fans in Parallel to the PWM3 Output Using a Single N-channel MOSFET www.onsemi.com 26 ADT7473 If the fan output has a resistive pullup to 12 V (or other voltage greater than 3.6 V), the fan output can be clamped with a Zener diode, as shown in Figure 41. The Zener diode voltage should be chosen so that it is greater than VIH of the TACH input, but less than 3.6 V, allowing for the voltage tolerance of the Zener. A value of between 3.0 V and 3.6 V is suitable. With a pullup voltage of 12 V and pullup resistor less than 1 kW, suitable values for R1 and R2 are 120 kW and 47 kW, respectively. This gives a high input voltage of 3.35 V. Fan Speed Measurement The fan counter does not count the fan TACH output pulses directly, because the fan speed could be less than 1,000 RPM and it would take several seconds to accumulate a reasonably large and accurate count. Instead, the period of the fan revolution is measured by gating an on-chip 90 kHz oscillator into the input of a 16-bit counter for N periods of the fan TACH output (see Figure 44), so the accumulated count is actually proportional to the fan tachometer period, and inversely proportional to the fan speed. N, the number of pulses counted, is determined by the settings of the TACH pulses per revolution register (Register 0x7B). This register contains two bits for each fan, allowing one, two (default), three, or four TACH pulses to be counted. VCC 12 V PULLUP 4.7 kW TYP TACH OUTPUT TACH FAN SPEED COUNTER ZD1* ADT7473/ ADT7473−1 *CHOOSE ZD1 VOLTAGE APPROXIMATELY 0.8 × VCC Figure 41. Fan with TACH Pullup to Voltage > 3.6 V, Clamped with Zener Diode CLOCK If the fan has a strong pullup (less than 1 kW) to 12 V or a totem-pole output, a series resistor can be added to limit the Zener current, as shown in Figure 42. 12 V PWM VCC TACH 1 2 3 TACH PULLUP TYP < 1 kW TACH OUTPUT ZD1* ZENER OR TOTEM-POLE 4 FAN SPEED COUNTER Figure 44. Fan Speed Measurement ADT7473/ ADT7473−1 Fan Speed Measurement Registers The fan tachometer readings are 16-bit values consisting of a 2-byte read from the ADT7473/ADT7473−1. *CHOOSE ZD1 VOLTAGE APPROXIMATELY 0.8 × VCC Figure 42. Fan with Strong TACH. Pullup to > VCC or Totem-Pole Output, Clamped with Zener and Resistor 12 V Table 34. FAN SPEED MEASUREMENT REGISTERS Register VCC < 1 kW TACH OUTPUT TACH FAN SPEED COUNTER R1* R2* ADT7473/ ADT7473−1 *SEE TEXT Figure 43. Fan with Strong TACH. Pullup to > VCC or Totem-Pole Output, Attenuated with R1/R2 Default 0x28 TACH1 Low Byte 0x00 0x29 TACH1 High Byte 0x00 0x2A TACH2 Low Byte 0x00 0x2B TACH2 High Byte 0x00 0x2C TACH3 Low Byte 0x00 0x2D TACH3 High Byte 0x00 0x2E TACH4 Low Byte 0x00 0x2F TACH4 High Byte 0x00 Reading Fan Speed from the ADT7473/ADT7473−1 The measurement of fan speeds involves a 2-register read for each measurement. The low byte should be read first. This causes the high byte to be frozen until both high and low byte registers have been read, preventing erroneous TACH readings. The fan tachometer reading registers report back the number of 11.11 ms period clocks (90 kHz oscillator) gated to the fan speed counter, from the rising edge of the first fan TACH pulse to the rising edge of the third fan TACH Alternatively, a resistive attenuator can be used, as shown in Figure 43. R1 and R2 should be chosen such that 2 V t V PULLUP Description R2ńǒR PULLUP ) R1 ) R2Ǔ t 3.6 V (eq. 3) The fan inputs have an input resistance of nominally 160 kW to ground, which should be taken into account when calculating resistor values. www.onsemi.com 27 ADT7473 Fan Speed (RPM) = (90,000 × 60)/Fan TACH Reading pulse (assuming two pulses per revolution are being counted). Because the device is essentially measuring the fan TACH period, the higher the count value, the slower the fan is actually running. A 16-bit fan tachometer reading of 0xFFFF indicates either the fan has stalled or is running very slowly (<100 RPM). where Fan TACH Reading is the 16-bit fan tachometer reading. Example TACH1 High Byte (Register 0x29) = 0x17 TACH1 Low Byte (Register 0x28) = 0xFF What is Fan 1 speed in RPM? Fan 1 TACH Reading = 0x17FF = 6143 (decimal) RPM = (f × 660)/Fan 1 TACH Reading RPM = (90000 × 660)/6143 Fan Speed = 879 RPM High Limit > Comparison Performed Because the actual fan TACH period is measured, falling below a fan TACH limit by 1 sets the appropriate status bit and can be used to generate an SMBALERT. Measuring Fan TACH When the ADT7473/ADT7473−1 starts up, TACH measurements are locked. In effect, an internal read of the low byte has been made for each TACH input. The net result of this is that all TACH readings are locked until the high byte is read from the corresponding TACH registers. All TACH related interrupts are also ignored until the appropriate high byte is read. Once the corresponding high byte has been read, TACH measurements are unlocked and interrupts are processed as normal. Fan Pulses per Revolution Different fan models can output either one, two, three, or four TACH pulses per revolution. Once the number of fan TACH pulses has been determined, it can be programmed into the fan pulses per revolution register (Register 0x7B) for each fan. Alternatively, this register can be used to determine the number or pulses per revolution output by a given fan. By plotting fan speed measurements at a 100% speed with different pulses per revolution setting, the smoothest graph with the lowest ripple determines the correct pulses per revolution value. Fan TACH Limit Registers The fan TACH limit registers are 16-bit values consisting of two bytes. Table 36. TACH PULSES/REVOLUTION REGISTER (REG. 0X7B) Table 35. FAN TACH LIMIT REGISTERS Register Description Default 0x54 TACH1 Minimum Low Byte 0xFF 0x55 TACH1 Minimum High Byte 0xFF 0x56 TACH2 Minimum Low Byte 0xFF 0x57 TACH2 Minimum High Byte 0xFF 0x58 TACH3 Minimum Low Byte 0xFF 0x59 TACH3 Minimum High Byte 0xFF 0x5A TACH4 Minimum Low Byte 0xFF 0x5B TACH4 Minimum High Byte 0xFF Bit Mnemonic <1:0> FAN1 Default 2 Pulses per Revolution Description <3:2> FAN2 Default 2 Pulses per Revolution <5:4> FAN3 Default 2 Pulses per Revolution <7:6> FAN4 Default 2 Pulses per Revolution Table 37. TACH PULSES/REVOLUTION REGISTER BIT VALUES Value Fan Speed Measurement Rate The fan TACH readings are normally updated once every second. The FAST bit (Bit 3) of Configuration Register 3 (0x78), when set, updates the fan TACH readings every 250 ms. If any of the fans are not being driven by a PWM channel but are powered directly from 5.0 V or 12 V, their associated dc bit in Configuration Register 3 should be set. This allows TACH readings to be taken on a continuous basis for fans connected directly to a dc source. For optimal results, the associated dc bit should always be set when using 4-wire fans. Description 00 1 Pulse per Revolution 01 2 Pulses per Revolution 10 3 Pulses per Revolution 11 4 Pulses per Revolution Fan Spin-up The ADT7473/ADT7473−1 has a unique fan spin-up function. It spins the fan at 100% PWM duty cycle until two TACH pulses are detected on the TACH input. Once two TACH pulses are detected, the PWM duty cycle goes to the expected running value, for example, 33%. The advantage is that fans have different spin-up characteristics and take different times to overcome inertia. The ADT7473/ ADT7473−1 runs the fans just fast enough to overcome inertia and is quieter on spin-up than fans programmed for a given spin-up time. Calculating Fan Speed Assuming a fan has two pulses per revolution (and two pulses per revolution being measured), fan speed is calculated by: www.onsemi.com 28 ADT7473 Fan Startup Timeout Table 40. PWM FREQUENCY REGISTERS (REG. 0X5F TO 0X61) To prevent the generation of false interrupts as a fan spins up (because it is below running speed), the ADT7473/ ADT7473−1 includes a fan startup timeout function. During this time, the ADT7473/ADT7473−1 looks for two TACH pulses. If two TACH pulses are not detected, an interrupt is generated. Using Configuration Register 1 (0x40), Bit 5 (FSPDIS), this functionality can be changed (see the Disabling Fan Startup Timeout section). Table 38. PWM1 TO PWM3 CONFIGURATION (REG. 0X5C TO 0X5E) Bit Mnemonic <2:0> FREQ Description 000 = 11.0 Hz 001 = 14.7 Hz 010 = 22.1 Hz 011 = 29.4 Hz 100 = 35.3 Hz (Default) 101 = 44.1 Hz 110 = 58.8 Hz 111 = 88.2 Hz Fan Speed Control Bit Mnemonic Description <2:0> SPIN These bits control the startup timeout for PWM1 (0x5C), PWM2 (0x5D), PWM3 (0x5E). 000 = No Startup Timeout 001 = 100 ms 010 = 250 ms (Default) 011 = 400 ms 100 = 667 ms 101 = 1 s 110 = 2 s 111 = 4 s The ADT7473/ADT7473−1 controls fan speed using automatic and manual modes. In automatic fan speed control mode, fan speed is automatically varied with temperature and without CPU intervention, once initial parameters are set up. The advantage of this is that, if the system hangs, the user is guaranteed the system is protected from overheating. The automatic fan speed control incorporates a feature called dynamic TMIN calibration. This feature reduces the design effort required to program the automatic fan speed control loop. For more information and procedures on how to program the automatic fan speed control loop and dynamic TMIN calibration, see the Programming the Automatic Fan Speed Control Loop section. In manual fan speed control mode, the ADT7473/ ADT7473−1 allows the duty cycle of any PWM output to be manually adjusted. This can be useful if the user wants to change fan speed in software or adjust the PWM duty cycle output for test purposes. Bits <7:5> of Register 0x5C to Register 0x5E (PWM configuration registers) control the behavior of each PWM output. Disabling Fan Startup Timeout Although fan startup makes fan spin-ups much quieter than fixed-time spin-ups, the option exists to use fixed spin-up times. Setting Bit 5 (FSPDIS) to 1 in Configuration Register 1 (0x40) disables the spin-up for two TACH pulses. Instead, the fan spins up for the fixed time as selected in Register 0x5C to Register 0x5E. PWM Logic State The PWM outputs can be programmed high for a 100% duty cycle (non-inverted) or low for a 100% duty cycle (inverted). Table 41. PWM CONFIGURATION (REG. 0X5C TO 0X5E) BITS Table 39. PWM1 TO PWM3 CONFIGURATION (REG. 0X5C TO 0X5E) BITS Bit Mnemonic Description 4 INV 0 = logic high for 100% PWM duty cycle 1 = logic low for 100% PWM duty cycle Bit Mnemonic <7:5> BHVR 111 Description Manual Mode Once under manual control, each PWM output can be manually updated by writing to Register 0x30 to Register 0x32 (PWM current duty cycle registers). Low Frequency Mode PWM Drive Frequency The PWM drive frequency can be adjusted for the application. Register 0x5F to Register 0x61 configure the PWM frequency for PWM1 to PWM3, respectively. In high frequency mode, the PWM drive frequency is always 22.5 kHz. Programming the PWM Current Duty Cycle Registers The PWM current duty cycle registers are 8-bit registers that allow the PWM duty cycle for each output to be set anywhere from 0% to 100% in steps of 0.39%. The value to be programmed into the PWMMIN register is given by: High Frequency Mode PWM Drive Value (decimal) + PWM MINń0.39 Setting Bit 3 of Register 0x5F, 60H or 61H enables high frequency mode for fans 1, 2 and 3. www.onsemi.com 29 (eq. 4) ADT7473 Example 1 Sleep States For a PWM duty cycle of 50% Value (decimal) = 50/0.39 = 128 (decimal) Value = 128 (decimal) or 0x80 (hex) The ADT7473/ADT7473−1 has been specifically designed to operate from a 3.3 V STBY supply. In computers that support S3 and S5 states, the core voltage of the processor is lowered in these states. If using the dynamic TMIN mode, lowering the core voltage of the processor changes the CPU temperature and the dynamics of the system under dynamic TMIN control. Likewise, when monitoring THERM, the THERM timer should be disabled during these states. Example 2 For a PWM duty cycle of 33% Value (decimal) = 33/0.39 = 85 (decimal) Value = 85 (decimal) or 0x54 (hex) Table 42. PWM CURRENT DUTY CYCLE REGISTERS Register Description Default 0x30 PWM1 Duty Cycle 0xFF (0%) 0x31 PWM2 Duty Cycle 0xFF (0%) 0x32 PWM3 Duty Cycle 0xFF (0%) Dynamic TMIN Control Register 1 (0X36) Bit <1> VCCPLO = 1 When the VCCP voltage drops below the VCCP low limit, the following occurs: 1. Status Bit 1 (VCCP) in Status Register 1 is set. 2. SMBALERT is generated, if enabled. 3. THERM monitoring is disabled. The THERM timer should hold its value prior to the S3 or S5 state. 4. Dynamic TMIN control is disabled. This prevents TMIN from being adjusted due to an S3 or S5 state. 5. The ADT7473/ADT7473−1 is prevented from entering the shutdown state. By reading the PWMx current duty cycle registers, the user can keep track of the current duty cycle on each PWM output, even when the fans are running in automatic fan speed control mode or acoustic enhancement mode. See the Programming the Automatic Fan Speed Control Loop section for details. Fan Presence Detect This feature can be used to determine if a 4-wire fan is directly connected to a PWM output. This feature does not work for 3-wire fans. To detect whether a 4-wire fan is connected directly to a PWM output, the following steps must be performed in this order: 1. Drive the appropriate PWM outputs to 100% duty cycle. 2. Set Bit 0 of Configuration Register 2 (0x73). 3. Wait 5 ms. 4. Program the fans to run at a different speed if necessary. 5. Read the state of Bits <3:1> of Configuration Register 2 (0x73). The state of these bits reflects whether a 4-wire fan is directly connected to the PWM output. Once the core voltage, VCCP, goes above the VCCP low limit, everything is re-enabled, and the system resumes normal operation. XNOR Tree Test Mode The ADT7473/ADT7473−1 includes an XNOR tree test mode. This mode is useful for in-circuit test equipment at board-level testing. By applying stimulus to the pins included in the XNOR tree, it is possible to detect opens or shorts on the system board. Figure 45 shows the signals that are exercised in the XNOR tree test mode. The XNOR tree test is invoked by setting Bit 0 (XEN) of the XNOR tree test enable register (0x6F). TACH1 TACH2 As the detection time only takes 5 ms, programming the PWM outputs to 100% and then back to their normal speed is not noticeable in most cases. TACH3 Description of How Fan Presence Detect Works TACH4 Typical 4-wire fans have an internal pull up to 4.75 V ±10%, which typically sources 5 mA. While the detection cycle is on, an internal current sink is turned on, sinking current from the fan’s internal pullup. By driving some of the current from the fan’s internal pullup (~100 mA), the logic buffer switches to a defined logic state. If this state is high, a fan is present; if it is low, no fan is present. The PWM input voltage should be clamped to 3.3 V. This ensures the PWM output is not pulled to a voltage higher than the maximum allowable voltage on that pin (3.6 V). PWM2 PWM3 PWM1/XTO Figure 45. XNOR Tree Test www.onsemi.com 30 ADT7473 Power-on Default Programming the Automatic Fan Speed Control Loop When the ADT7473 is powered up, it polls the VCCP input. By default, the ADT7473−1 powers up with fans running, eliminating the need for polling of VCCP. If VCCP stays below 0.75 V (the system CPU power rail is not powered up), the ADT7473 assumes the functionality of the default registers after the ADT74731 is addressed via any valid SMBus transaction. If VCC goes high (the system processor power rail is powered up), a fail-safe timer begins to count down. If the ADT7473 is not addressed by any valid SMBus transactions before the fail-safe timeout (4.6 seconds) lapses, the ADT7473 drives the fans to full speed. If the ADT7473 is addressed by a valid SMBus transaction after this point, the fans stop, and the ADT7473 assumes its default settings and begins normal operation. If VCCP goes high (the system processor power rail is powered up), then a fail-safe timer begins to count down. If the ADT7473 is addressed by a valid SMBus transaction before the fail-safe timeout (4.6 seconds) lapses, then the ADT7473 operates normally, assuming the functionality of all the default registers. See the flow chart in Figure 46. To understand the automatic fan speed control loop, it is strongly recommended to use the ADT7473/ADT7473−1 evaluation board and software while reading this section. This section provides the system designer with an understanding of the automatic fan control loop, and provides step-by-step guidance on effectively evaluating and selecting critical system parameters. To optimize the system characteristics, the designer needs to consider the system configuration, including the number of fans, where they are located, and what temperatures are measured in the particular system. The mechanical or thermal engineer who is tasked with the system thermal characterization should also be involved at the beginning of the process. Automatic Fan Control Overview The ADT7473/ADT7473−1 can automatically control the speed of fans based on the measured temperature. This is done independently of CPU intervention once initial parameters are set up. The ADT7473/ADT7473−1 has a local temperature sensor and two remote temperature channels that can be connected to a CPU on-chip thermal diode (available on Intel Pentium class CPUs and other CPUs). These three temperature channels can be used as the basis for automatic fan speed control to drive fans using PWM. Automatic fan speed control reduces acoustic noise by optimizing fan speed according to accurately measured temperature. Reducing fan speed can also decrease system current consumption. The automatic fan speed control mode is very flexible due to the number of programmable parameters, including TMIN and TRANGE. The TMIN and TRANGE values for a temperature channel and, therefore, for a given fan, are critical because they define the thermal characteristics of the system. The thermal validation of the system is one of the most important steps in the design process, so these values should be selected carefully. Figure 47 gives a top-level overview of the automatic fan control circuitry on the ADT7473/ADT7473−1. From a systems-level perspective, up to three system temperatures can be monitored and used to control three PWM outputs. The three PWM outputs can be used to control up to four fans. The ADT7473/ADT7473−1 allows the speed of four fans to be monitored. Each temperature channel has a thermal calibration block, allowing the designer to individually configure the thermal characteristics of each temperature channel. For example, a designer can decide to run the CPU fan when CPU temperature increases above 60°C, and a chassis fan when the local temperature increases above 45°C. At this stage, the designer has not assigned these thermal calibration settings to a particular fan drive (PWM) channel. The right side of Figure 47 shows controls that are fan-specific. The designer has individual control over parameters such as minimum PWM duty cycle, fan ADT7473/ADT7473−1 IS POWERED UP Y HAS THE ADT7473/ ADT7473−1 BEEN ACCESSED BY A VALID SMBus TRANSACTION? N N IS VCCP ABOVE 0.75 V? CHECK VCCP Y START FAIL-SAFE TIMER Y HAS THE ADT7473/ ADT7473−1 BEEN ACCESSED BY A VALID SMBus TRANSACTION? N FAIL-SAFE TIMER ELAPSES AFTER THE FAIL-SAFE TIMEOUT HAS THE ADT7473/ ADT7473−1 BEEN ACCESSED BY A VALID SMBus TRANSACTION? Y N RUNS THE FANS TO FULL SPEED HAS THE ADT7473/ ADT7473−1 BEEN ACCESSED BY A VALID SMBus TRANSACTION? N Y START UP THE ADT7473/ ADT7473−1 NORMALLY SWITCH OFF FANS Figure 46. Power-on Flow Chart www.onsemi.com 31 ADT7473 speed failure thresholds, and even ramp control of the PWM outputs. Automatic fan control, then, ultimately allows graceful fan speed changes that are less perceptible to the system user. THERMAL CALIBRATION S REMOTE1 TEMP TMIN TRANGE PWM MIN THERMAL CALIBRATION S MUX TMIN TRANGE 0% PWM MIN THERMAL CALIBRATION 100% S REMOTE2 TEMP TMIN TRANGE RAMP CONTROL (ACOUSTIC ENHANCEMENT) PWM GENERATOR PWM1 0% 100% LOCAL TEMP PWM CONFIG PWM MIN 100% TACHOMETER 1 MEASUREMENT RAMP CONTROL (ACOUSTIC ENHANCEMENT) TACHOMETER 2 MEASUREMENT RAMP CONTROL (ACOUSTIC ENHANCEMENT) TACHOMETER 3 AND 4 MEASUREMENT 0% TACH1 PWM CONFIG PWM GENERATOR PWM2 TACH2 PWM CONFIG PWM GENERATOR PWM3 TACH3 Figure 47. Automatic Fan Control Block Diagram Step 1: Hardware Configuration This influences the choice of whether to use the TACH4 pin or to reconfigure it for the THERM function. 3. Is the CPU fan to be controlled using the ADT7473/ADT7473−1 or will it run at full speed 100% of the time? If run at full speed, 100% of the time, this frees up a PWM output, but the system is louder. 4. Where will the ADT7473/ADT7473−1 be physically located in the system? This influences the assignment of the temperature measurement channels to particular system thermal zones. For example, locating the ADT7473/ADT7473−1 close to the VRM controller circuitry allows the VRM temperature to be monitored using the local temperature channel. During system design, the motherboard sensing and control capabilities should be addressed early in the design stages. Decisions about how these capabilities are used should involve the system thermal/mechanical engineer. Consider the following questions: 1. What ADT7473/ADT7473−1 functionality will be used? • PWM2 or SMBALERT for ADT7473? • THERM_LATCH or PWM2 for ADT7473−1? • TACH4 fan speed measurement or over-temperature THERM function? The ADT7473/ ADT7473−1 offers multifunctional pins that can be reconfigured to suit different system requirements and physical layouts. These multifunction pins are software programmable. 2. How many fans will be supported in the system, three or four? www.onsemi.com 32 ADT7473 THERMAL CALIBRATION PWM MIN 100% RAMP CONTROL (ACOUSTIC ENHANCEMENT) S TMIN REMOTE1 = AMBIENT TEMP TRANGE 0% 100% LOCAL = VRM TEMP TRANGE RAMP CONTROL (ACOUSTIC ENHANCEMENT) S MUX PWM MIN RAMP CONTROL (ACOUSTIC ENHANCEMENT) 100% S TMIN TRANGE TACH1 PWM GENERATOR PWM CONFIG CPU FAN SINK PWM2 TACH2 FRONT CHASSIS PWM GENERATOR TACHOMETER3 AND 4 MEASUREMENT 0% PWM1 PWM CONFIG TACHOMETER2 MEASUREMENT 0% THERMAL CALIBRATION PWM GENERATOR TACHOMETER1 MEASUREMENT PWM MIN THERMAL CALIBRATION TMIN PWM CONFIG PWM3 TACH3 REMOTE2 = CPU TEMP REAR CHASSIS Figure 48. Hardware Configuration Example ADT7473 FRONT CHASSIS FAN TACH2 PWM1 TACH1 CPU FAN PWM3 REAR CHASSIS FAN TACH3 D2+ D2− THERM PROCHOT D1+ AMBIENT TEMPERATURE CPU D1− SDA SCL SMBALERT GND Figure 49. Recommended Implementation 1 www.onsemi.com 33 ICH ADT7473 Recommended Implementation 1 multiple temperature channels. The mux is the bridge between temperature measurement channels and the three PWM outputs. Bits <7:5> (BHVR) of Register 0x5C, Register 0x5D, and Register 0x5E (PWM configuration registers) control the behavior of the fans connected to the PWM1, PWM2, and PWM3 outputs. The values selected for these bits determine how the mux connects a temperature measurement channel to a PWM output. Configuring the ADT7473, as in Figure 49 provides the system designer with the following features: • Two PWM outputs for fan control of up to three fans. (The front and rear chassis fans are connected in parallel.) • Three TACH fan speed measurement inputs. • VCC measured internally through Pin 4. • CPU core voltage measurement (VCORE). • VRM temperature using local temperature sensor. • CPU temperature measured using the Remote 1 temperature channel. • Ambient temperature measured through the Remote 2 temperature channel. • Bidirectional THERM pin allows the monitoring of PROCHOT output from an Intel® Pentium® 4 processor, for example, or can be used as an overtemperature THERM output. • SMBALERT system interrupt output. Automatic Fan Control Mux Options Bits <7:5> (BHVR), Register 0x5C, Register 0x5D, Register 0x5E. 000 = Remote 1 temperature controls PWMx 001 = Local temperature controls PWMx 010 = Remote 2 temperature controls PWMx 101 = Fastest speed calculated by local and Remote 2 temperature controls PWMx 110 = Fastest speed calculated by all three temperature channel controls PWMx The fastest speed calculated options pertain to controlling one PWM output based on multiple temperature channels. The thermal characteristics of the three temperature zones can be set to drive a single fan. An example is the fan turning on when Remote 1 temperature exceeds 60°C, or if the local temperature exceeds 45°C. Step 2: Configuring the Mux After the system hardware configuration is determined, the fans can be assigned to particular temperature channels. Not only can fans be assigned to individual channels, but the behavior of the fans is also configurable. For example, fans can be run under automatic fan control, manually (under software control), or at the fastest speed calculated by MUX THERMAL CALIBRATION PWM MIN 100% S TMIN REMOTE1 = AMBIENT TEMP TRANGE S MUX LOCAL = VRM TEMP S REMOTE2 = CPU TEMP TACHOMETER2 MEASUREMENT PWM MIN 100% TRANGE RAMP CONTROL (ACOUSTIC ENHANCEMENT) 0% THERMAL CALIBRATION TMIN TACHOMETER1 MEASUREMENT PWM MIN 100% TRANGE RAMP CONTROL (ACOUSTIC ENHANCEMENT) 0% THERMAL CALIBRATION TMIN PWM CONFIG RAMP CONTROL (ACOUSTIC ENHANCEMENT) PWM GENERATOR TACH1 PWM CONFIG PWM GENERATOR PWM CONFIG Figure 50. Assigning Temperature Channels to Fan Channels www.onsemi.com 34 CPU FAN SINK PWM2 TACH2 FRONT CHASSIS PWM GENERATOR TACHOMETER3 AND 4 MEASUREMENT 0% PWM1 PWM3 TACH3 REAR CHASSIS ADT7473 Other Mux Options Bits <7:5> (BHVR), Register 0x5C, Register 0x5D, Register 0x5E. 011 = PWMx runs full speed (default for ADT7473−1) 100 = PWMx disabled (default for ADT7473) 111 = manual mode Remote 2 (processor) temperature. In this case, the CPU fan sink is also used to cool the VRM. PWM2 (front chassis fan) is controlled by the Remote 1 temperature (ambient). PWM3 (rear chassis fan) is controlled by the Remote 1 temperature (ambient). • • In normal mode, PWMx runs under software control. In this mode, PWM duty cycle registers (Register 0x30 to Register 0x32) are writable and control the PWM outputs. Example Mux Settings Bits <7:5> (BHVR), PWM1 Configuration Register (0x5C) 101 = Fastest speed calculated by local and Remote 2 temperature controls PWM1 Bits <7:5> (BHVR), PWM2 Configuration Register (0x5D) 000 = Remote 1 temperature controls PWM2 Bits <7:5> (BHVR), PWM3 Configuration Register (0x5E) 000 = Remote 1 temperature controls PWM3 Mux Configuration Example This is an example of how to configure the mux in a system using the ADT7473/ADT7473−1 to control three fans. The CPU fan sink is controlled by PWM1, the front chassis fan is controlled by PWM2, and the rear chassis fan is controlled by PWM3. The mux is configured for the following fan control behaviors: • PWM1 (CPU fan sink) is controlled by the fastest speed calculated by the local (VRM temperature) and These settings configure the mux, as shown in Figure 51. THERMAL CALIBRATION PWM MIN 100% S TMIN REMOTE2 = CPU TEMP TRANGE MUX S LOCAL = VRM TEMP TACHOMETER2 MEASUREMENT PWM MIN 100% S TRANGE RAMP CONTROL (ACOUSTIC ENHANCEMENT) 0% THERMAL CALIBRATION TMIN TACHOMETER1 MEASUREMENT PWM MIN 100% TRANGE RAMP CONTROL (ACOUSTIC ENHANCEMENT) 0% THERMAL CALIBRATION TMIN PWM CONFIG RAMP CONTROL (ACOUSTIC ENHANCEMENT) TACHOMETER3 AND 4 MEASUREMENT 0% PWM GENERATOR PWM1 TACH1 PWM CONFIG PWM GENERATOR PWM CONFIG CPU FAN SINK PWM2 TACH2 FRONT CHASSIS PWM GENERATOR PWM3 TACH3 REMOTE1 = AMBIENT TEMP Figure 51. Mux Configuration Example Step 3: TMIN Settings for Thermal Calibration Channels REAR CHASSIS the TMIN value is exceeded, the fan turns on and runs at the minimum PWM duty cycle. The fan turns off once the temperature drops below TMIN − THYST. To overcome fan inertia, the fan is spun up until two valid TACH rising edges are counted. See the Fan Startup Timeout section for more details. In some cases, primarily for psycho-acoustic reasons, it is desirable that the fan never switches off below TMIN. Bits <7:5> of Enhanced Acoustics Register 1 (0x62), when set, can keep the fans running at the PWM minimum duty cycle, if the temperature falls below TMIN. TMIN is the temperature at which the fans start to turn on under automatic fan control. The speed at which the fan runs at TMIN is programmed later. The TMIN values chosen are temperature channel specific, for example, 25°C for ambient channel, 30°C for VRM temperature, and 40°C for processor temperature. TMIN is an 8-bit value, either twos complement or Offset 64, that can be programmed in 1°C increments. A TMIN register is associated with each temperature measurement channel: Remote 1 local and Remote 2 temperature. Once www.onsemi.com 35 ADT7473 Bit 7 (MIN3) = 1, PWM3 runs at PWM3 minimum duty cycle below TMIN − THYST. Bit 6 (MIN2) = 0, PWM2 is off (0% PWM duty cycle) when temperature is below TMIN − THYST. Bit 6 (MIN2) = 1, PWM2 runs at PWM2 minimum duty cycle below TMIN − THYST. Bit 5 (MIN1) = 0, PWM1 is off (0% PWM duty cycle) when temperature is below TMIN − THYST. Bit 5 (MIN1) = 1, PWM1 runs at PWM1 minimum duty cycle below TMIN − THYST. Table 43. TMIN REGISTERS Register Description Default 0x67 Remote 1 Temperature TMIN 0x9A (90°C) 0x68 Local Temperature TMIN 0x9A (90°C) 0x69 Remote 2 Temperature TMIN 0x9A (90°C) Enhanced Acoustics Register 1 (0x62) Bit 7 (MIN3) = 0, PWM3 is off (0% PWM duty cycle) when temperature is below TMIN − THYST. PWM DUTY CYCLE 100% 0% TMIN THERMAL CALIBRATION PWM MIN 100% PWM CONFIG RAMP CONTROL (ACOUSTIC ENHANCEMENT) S TMIN TRANGE LOCAL = VRM TEMP RAMP CONTROL (ACOUSTIC ENHANCEMENT) S MUX TRANGE TACHOMETER1 MEASUREMENT PWM MIN 100% TMIN TACHOMETER2 MEASUREMENT 0% PWM MIN THERMAL CALIBRATION RAMP CONTROL (ACOUSTIC ENHANCEMENT) 100% S TMIN REMOTE1 = AMBIENT TEMP TRANGE PWM1 0% THERMAL CALIBRATION REMOTE2 = CPU TEMP PWM GENERATOR TACH1 PWM CONFIG PWM GENERATOR PWM CONFIG PWM2 TACH2 FRONT CHASSIS PWM GENERATOR TACHOMETER3 AND 4 MEASUREMENT 0% CPU FAN SINK PWM3 TACH3 Figure 52. Understanding the TMIN Parameter REAR CHASSIS Step 4: PWMMIN for Each PWM (Fan) Output PWMMIN is the minimum PWM duty cycle at which each fan in the system runs. It is also the start speed for each fan under automatic fan control once the temperature rises above TMIN (see Figure 53). For maximum system acoustic benefit, PWMMIN should be set as low as possible. Depending on the fan used, the PWMMIN setting is usually in the 20% to 33% duty cycle range. This value can be found through fan validation. PWM DUTY CYCLE 100% PWMMIN 0% TMIN TEMPERATURE Figure 53. PWMMIN Determines Minimum PWM Duty Cycle www.onsemi.com 36 ADT7473 not equate to running the fan at 33% speed. Driving a fan at 33% PWM duty cycle actually runs the fan at closer to 50% of its full speed. This is because fan speed in %RPM generally relates to the square root of PWM duty cycle. Given a PWM square wave as the drive signal, fan speed in RPM approximates to: More than one PWM output can be controlled from a single temperature measurement channel. For example, Remote 1 temperature can control PWM1 and PWM2 outputs. If two different fans are used on PWM1 and PWM2, the fan characteristics can be set up differently. As a result, Fan 1 driven by PWM1 can have a different PWMMIN value than that of Fan 2 connected to PWM2. Figure 54 illustrates this as PWM1MIN (front fan) is turned on at a minimum duty cycle of 20%, while PWM2MIN (rear fan) turns on at a minimum of 40% duty cycle. However, both fans turn on at exactly the same temperature, defined by TMIN. % fanspeed + ǸPWM duty cycle PWMMAX is the maximum duty cycle at which each fan in the system runs under the automatic fan speed control loop. For maximum system acoustic benefit, PWMMAX should be as low as possible, but should be capable of maintaining the processor temperature limit at an acceptable level. If the THERM temperature limit is exceeded, the fans are still boosted to 100% for fail-safe cooling (see Figure 55). There is a PWMMAX limit for each fan channel. The default value of this register is 0xFF and thus has no effect unless it is programmed. PWM DUTY CYCLE PWM2 PWM1 PWM1MIN 0% TMIN (eq. 5) Step 5: PWMMAX for PWM (Fan) Outputs 100% PWM2MIN 10 TEMPERATURE 100% PWM DUTY CYCLE Figure 54. Operating Two Different Fans from a Single Temperature Channel Programming the PWMMIN Registers The PWMMIN registers are 8-bit registers that allow the minimum PWM duty cycle for each output to be configured anywhere from 0% to 100%. This allows the minimum PWM duty cycle to be set in steps of 0.39%. The value to be programmed into the PWMMIN register is given by: Value (decimal) = PWMMIN/0.39 PWMMAX PWMMIN 0% TMIN TEMPERATURE Figure 55. PWMMAX Determines Maximum PWM Duty Cycle Below the THERM Temperature Limit Example 1 Programming the PWMMAX Registers For a minimum PWM duty cycle of 50% Value (decimal) = 50/0.39 = 128 (decimal) Value = 128 (decimal) or 80 (hex) The PWMMAX registers are 8-bit registers that allow the maximum PWM duty cycle for each output to be configured anywhere from 0% to 100%. This allows the maximum PWM duty cycle to be set in steps of 0.39%. The value to be programmed into the PWMMAX register is given by: Value (decimal) = PWMMAX/0.39 Example 2 For a minimum PWM duty cycle of 33% Value (decimal) = 33/0.39 = 85 (decimal) Value = 85 (decimal) or 54 (hex) Example 1 Table 44. PWMMIN REGISTERS Register Description For a maximum PWM duty cycle of 50% Value (decimal) = 50/0.39 = 128 (decimal) Value = 128 (decimal) or 80 (hex) Default 0x64 PWM1 Minimum Duty Cycle 0x80 (50%) 0x65 PWM2 Minimum Duty Cycle 0x80 (50%) 0x66 PWM3 Minimum Duty Cycle 0x80 (50%) Example 2 For a minimum PWM duty cycle of 75% Value (decimal) = 75/0.39 = 85 (decimal) Value = 192 (decimal) or C0 (hex) Note on Fan Speed and PWM Duty Cycle The PWM duty cycle does not directly correlate to fan speed in RPM. Running a fan at 33% PWM duty cycle does www.onsemi.com 37 ADT7473 4. Graphically program and visualize this functionality using the ADT7473/ADT7473−1 evaluation software. Table 45. PWMMAX REGISTERS Register Description Default 0x38 PWM1 Maximum Duty Cycle 0xFF (100%) 0x39 PWM2 Maximum Duty Cycle 0xFF (100%) 0x3A PWM3 Maximum Duty Cycle 0xFF (100%) Figure 57 shows how adjusting PWMMIN affects TRANGE. TRANGE is implemented as a slope, which means that as PWMMIN is changed, TRANGE changes, but the actual slope remains the same. The higher the PWMMIN value, the smaller the effective TRANGE, that is, the fan reaches full speed (100%) at a lower temperature. Figure 58 shows how increasing PWMMIN changes the effective TRANGE. See the Note on Fan Speed and PWM Duty Cycle section. Step 6: TRANGE for Temperature Channels TRANGE is the range of temperature over which automatic fan control occurs once the programmed TMIN temperature is exceeded. TRANGE is a temperature slope, not an arbitrary value, that is, a TRANGE of 40°C holds true only for PWMMIN = 33%. If PWMMIN is increased or decreased, the effective TRANGE changes. Refer to Figure 56. PWM DUTY CYCLE 100% TRANGE PWM DUTY CYCLE 100% 50% 33% 25% 10% 0% 30°C 40°C 45°C 54°C PWMMIN 0% TMIN TMIN Figure 58. Increasing PWMMIN Changes Effective TRANGE TEMPERATURE Figure 56. TRANGE Parameter Affects Cooling Slope For a given TRANGE value, the temperature at which the fan runs at full speed for different PWMMIN values can be easily calculated as follows: TMAX = TMIN + (Max DC − Min DC) × TRANGE /170 where: TMAX is the temperature at which the fan runs full speed. TMIN is the temperature at which the fan turns on. Max DC is the maximum duty cycle (100%) = 255 decimal. Min DC is equal to PWMMIN. TRANGE is the duty PWM duty cycle vs. temperature slope. The TRANGE or fan control slope is determined by the following procedure: 1. Determine the maximum operating temperature for that channel (for example, 70°C). 2. Determine experimentally the fan speed (PWM duty cycle value) that does not exceed the temperature at the worst-case operating points (for example, 70°C is reached when the fans are running at 50% PWM duty cycle). 3. Determine the slope of the required control loop to meet these requirements. Example 1 50% Calculate T, given that TMIN = 30°C, TRANGE = 40°C, and PWMMIN = 10% duty cycle = 26 (decimal). TMAX = TMIN + (Max DC − Min DC) × TRANGE /170 TMAX = 30°C + (100% − 10%) × 40°C/170 TMAX = 30°C + (255 − 26) × 40°C/170 TMAX = 84°C (effective TRANGE = 54°C) 33% Example 2 PWM DUTY CYCLE 100% Calculate TMAX, given that TMIN = 30°C, TRANGE = 40°C, and PWMMIN = 25% duty cycle = 64 (decimal). TMAX = TMIN + (Max DC − Min DC) × TRANGE /170 TMAX = 30°C + (100% − 25%) × 40°C/170 TMAX = 30°C + (255 − 64) × 40°C/170 TMAX = 75°C (effective TRANGE = 45°C) 0% 30°C 40°C TMIN Figure 57. Adjusting PWMMIN Affects TRANGE www.onsemi.com 38 ADT7473 Example 3 Increasing or decreasing PWMMIN changes the effective TRANGE, although the fan control still follows the same PWM duty cycle to temperature slope. The effective TRANGE for different PWMMIN values can be calculated using Equation 7. Calculate TMAX, given that TMIN = 30°C, TRANGE = 40°C, and PWMMIN = 33% duty cycle = 85 (decimal). TMAX = TMIN + (Max DC − Min DC) × TRANGE /170 TMAX = 30°C + (100% − 33%) × 40°C/170 TMAX = 30°C + (255 − 85) × 40°C/170 TMAX = 70°C (effective TRANGE = 40°C) T MAX + T MIN ) ǒMax DC * Min DCǓ (eq. 7) where (Max DC − Min DC) × TRANGE/170 is the effective TRANGE value. See the Note on Fan Speed and PWM Duty Cycle section. Figure 59 shows PWM duty cycle vs. temperature for each TRANGE setting. The lower graph shows how each TRANGE setting affects fan speed vs. temperature. As indicated by the graph, the effect on fan speed is nonlinear. The graphs in Figure 59 assume the fan starts from 0% PWM duty cycle. Clearly, the minimum PWM duty cycle, PWMMIN, needs to be factored in to see how the loop actually performs in the system. Figure 60 shows how TRANGE is affected when the PWMMIN value is set to 20%. It can be seen that the fan actually runs at about 45% fan speed when the temperature exceeds TMIN. Example 4 Calculate TMAX, given that TMIN = 30°C, TRANGE = 40°C, and PWMMIN = 50% duty cycle = 128 (decimal). TMAX = TMIN + (Max DC − Min DC) × TRANGE /170 TMAX = 30°C + (100% − 50%) × 40°C/170 TMAX = 30°C + (255 − 128) × 40°C/170 TMAX = 60°C (effective TRANGE = 30°C) Selecting a TRANGE Slope The TRANGE value can be selected for each temperature channel: Remote 1, local, and Remote 2. Bits <7:4> (TRANGE) of Register 0x5F to Register 0x61 define the TRANGE value for each temperature channel. Table 46. SELECTING A TRANGE VALUE TRANGE (5C) 100 0000 2 90 0001 2.5 80 PWM DUTY CYCLE (%) Bits <7:4> (Note 1) 0010 3.33 0011 4 0100 5 25C 2.55C 3.335C 45C 55C 70 6.675C 85C 60 105C 50 13.35C 165C 40 0101 6.67 0110 8 0111 10 1000 13.33 10 1001 16 0 1010 20 1011 26.67 1100 32 (Default) 1101 40 1110 53.33 1111 80 205C 30 26.65C 325C 20 405C 53.35C 0 20 40 60 80 100 120 805C TEMPERATURE ABOVE TMIN 25C 100 2.55C FAN SPEED (% OF MAX) 90 1. Register 0x5F configures Remote 1 TRANGE; Register 0x60 configures local TRANGE; Register 0x61 configures Remote 2 TRANGE. Summary of TRANGE Function When using the automatic fan control function, the temperature at which the fan reaches full speed can be calculated by: T MAX + T MIN ) T TRANGE T TRANGEń170 3.335C 45C 80 55C 70 6.675C 85C 60 105C 50 13.35C 165C 40 205C 30 26.65C 325C 20 405C 10 0 (eq. 6) 53.35C 805C 0 20 40 60 80 100 120 TEMPERATURE ABOVE TMIN Equation 6 holds true only when PWMMIN is equal to 33% PWM duty cycle. Figure 59. TRANGE vs. Actual Fan Speed Profile www.onsemi.com 39 ADT7473 25C 100 3.335C 90 45C 80 PWM DUTY CYCLE (%) PWM DUTY CYCLE (%) 80 55C 70 6.675C 85C 60 105C 50 13.35C 165C 40 205C 30 26.65C 325C 20 70 60 50 40 30 20 405C 10 0 100 2.55C 90 10 53.35C 805C 0 20 40 60 80 100 0 120 0 10 TEMPERATURE ABOVE TMIN 25C 45C 80 55C 70 6.675C 85C 60 105C 50 13.35C 165C 40 205C 30 26.65C 325C 20 405C 10 60 80 100 60 70 80 90 100 120 90 100 80 70 60 50 40 30 20 10 53.35C 40 50 90 3.335C FAN SPEED (% MAX RPM) FAN SPEED (% OF MAX) 90 20 40 100 2.55C 0 30 TEMPERATURE ABOVE TMIN 100 0 20 805C 0 0 10 20 30 40 50 60 70 80 TEMPERATURE ABOVE TMIN TEMPERATURE ABOVE TMIN Figure 60. TRANGE and % Fan Speed Slopes with PWMMIN = 20% Figure 61. TRANGE and % Fan Speed Slopes for VRM, Ambient, and CPU Temperature Channels Example: Determining TRANGE for Each Temperature Channel Step 7: TTHERM for Temperature Channels TTHERM is the absolute maximum temperature allowed on a temperature channel. When operating above this temperature, a component such as the CPU or VRM might be beyond its safe operating limit. When the temperature measured exceeds TTHERM all fans are driven at 100% PWM duty cycle (full speed) to provide critical system cooling. The fans remain running at 100% until the temperature drops below TTHERM − hysteresis, where hysteresis is the number programmed into the hysteresis registers (Register 0x6D and Register 0x6E). The default hysteresis value is 4°C. The TTHERM limit should be considered the maximum worst-case operating temperature of the system. Because exceeding any TTHERM limit runs all fans at 100%, it has very negative acoustic effects. Ultimately, this limit should be set up as a fail-safe, and it should not be exceeded under normal system operating conditions. Note that the TTHERM limits are nonmaskable and affect the fan speed no matter how the automatic fan control settings are configured. This allows some flexibility because a TRANGE value can be selected based on its slope, while a The following example shows how the different TMIN and TRANGE settings can be applied to three different thermal zones. In this example, the following TRANGE values apply: TRANGE = 80°C for ambient temperature TRANGE = 53.3°C for CPU temperature TRANGE = 40°C for VRM temperature This example uses the mux configuration described in the Step 2: Configuring the Mux section, with the ADT7473/ ADT7473−1 connected as shown in Figure 61. Both CPU temperature and VRM temperature drive the CPU fan connected to PWM1. Ambient temperature drives the front chassis fan and rear chassis fan connected to PWM2 and PWM3. The front chassis fan is configured to run at PWMMIN = 20%. The rear chassis fan is configured to run at PWMMIN = 30%. The CPU fan is configured to run at PWMMIN = 10%. Note on 4-wire Fans The control range for 4-wire fans is much wider than that for 3-wire fans. In many cases, 4-wire fans can start with a PWM drive of as little as 20%. www.onsemi.com 40 ADT7473 Hysteresis Registers hard limit (such as 70°C), can be programmed as TMAX (the temperature at which the fan reaches full speed) by setting TTHERM to that limit (for example, 70°C). Register 0x6D, Remote 1 Local Temperature Hysteresis Register Bits <7:4> Remote 1 temperature hysteresis (4°C default) Bits <3:0> Local temperature hysteresis (4°C default) Register 0x6E, Remote 2 Temperature Hysteresis Register Bits <7:4> Remote 2 temperature hysteresis (4°C default) Table 47. THERM REGISTERS Register Description Default 0x6A Remote 1 THERM Temperature Limit 0xA4 (100°C) 0x6B Local THERM Temperature Limit 0xA4 (100°C) 0x6C Remote 2 THERM Temperature Limit 0xA4 (100°C) Because each hysteresis setting is four bits, hysteresis values are programmable from 1°C to 15°C. It is not recommended that hysteresis values be programmed to 0°C, because this disables hysteresis. In effect, this would cause the fans to cycle between normal speed and 100% speed, creating unsettling acoustic noise. TRANGE PWM DUTY CYCLE 100% 0% TMIN TTHERM THERMAL CALIBRATION PWM MIN 100% S TMIN TRANGE PWM MIN 100% S MUX TMIN LOCAL = VRM TEMP TRANGE 0% PWM MIN THERMAL CALIBRATION 100% S TMIN REMOTE1 = AMBIENT TEMP TRANGE RAMP CONTROL (ACOUSTIC ENHANCEMENT) PWM GENERATOR PWM1 0% THERMAL CALIBRATION REMOTE2 = CPU TEMP PWM CONFIG TACHOMETER1 MEASUREMENT RAMP CONTROL (ACOUSTIC ENHANCEMENT) TACHOMETER2 MEASUREMENT RAMP CONTROL (ACOUSTIC ENHANCEMENT) TACH1 PWM CONFIG PWM GENERATOR PWM CONFIG Figure 62. How TTHERM Relates to Automatic Fan Control Step 8: THYST for Temperature Channels PWM2 TACH2 FRONT CHASSIS PWM GENERATOR TACHOMETER3 AND 4 MEASUREMENT 0% CPU FAN SINK PWM3 TACH3 REAR CHASSIS The THYST value chosen determines the amount of time needed for the system to cool down or heat up as the fan turns on and off. Values of hysteresis are programmable in the range 1°C to 15°C. Larger values of THYST prevent the fans from chattering on and off. The THYST default value is set at 4°C. THYST is the amount of extra cooling a fan provides after the temperature measured has dropped back below TMIN before the fan turns off. The premise for temperature hysteresis (THYST) is that, without it, the fan would merely chatter or cycle on and off regularly whenever temperature is hovering at about the TMIN setting. www.onsemi.com 41 ADT7473 The THYST setting applies not only to the temperature hysteresis for fan on/off, but the same setting is used for the TTHERM hysteresis value, described in Step 6: TRANGE for Temperature Channels section. Therefore, programming Register 0x6D and Register 0x6E sets the hysteresis for both fan on/off and the THERM function. Bits <3:0>, Local temperature hysteresis (4°C default) Register 0x6E, Remote 2 Temperature Hysteresis Register Bits <7:4>, Remote 2 temperature hysteresis (4°C default) In some applications, it is required that fans not turn off below TMIN, but remain running at PWMMIN. Bits <7:5> of the Enhanced Acoustics Register 1 (0x62) allow the fans to be turned off or to be kept spinning below TMIN. If the fans are always on, the THYST value has no effect on the fan when the temperature drops below TMIN. Hysteresis Registers Register 0x6D, Remote 1, Local Hysteresis Register Bits <7:4>, Remote 1 temperature hysteresis (4°C default) TRANGE PWM DUTY CYCLE 100% 0% TMIN TTHERM THERMAL CALIBRATION PWM MIN 100% S TMIN TRANGE PWM MIN 100% S MUX TMIN LOCAL = VRM TEMP TRANGE 0% PWM MIN THERMAL CALIBRATION 100% S TMIN TRANGE RAMP CONTROL (ACOUSTIC ENHANCEMENT) PWM GENERATOR PWM1 0% THERMAL CALIBRATION REMOTE2 = CPU TEMP PWM CONFIG TACHOMETER1 MEASUREMENT RAMP CONTROL (ACOUSTIC ENHANCEMENT) TACHOMETER2 MEASUREMENT RAMP CONTROL (ACOUSTIC ENHANCEMENT) TACH1 PWM CONFIG PWM GENERATOR PWM CONFIG PWM2 TACH2 FRONT CHASSIS PWM GENERATOR TACHOMETER3 AND 4 MEASUREMENT 0% CPU FAN SINK PWM3 TACH3 REMOTE1 = AMBIENT TEMP REAR CHASSIS Figure 63. The THYST Value Applies to Fan On/Off Hysteresis and THERM Hysteresis Enhanced Acoustics Register 1 (0x62) Bit 5 (MIN1) = 0, PWM1 is off (0% PWM duty cycle) when temperature is below TMIN − THYST. Bit 5 (MIN1) = 1, PWM1 runs at PWM1 minimum duty cycle below TMIN − THYST. Bit 7 (MIN3) = 0, PWM3 is off (0% PWM duty cycle) when temperature is below TMIN − THYST. Bit 7 (MIN3) = 1, PWM3 runs at PWM3 minimum duty cycle below TMIN − THYST. Bit 6 (MIN2) = 0, PWM2 is off (0% PWM duty cycle) when temperature is below TMIN − THYST. Bit 6 (MIN2) = 1, PWM2 runs at PWM2 minimum duty cycle below TMIN − THYST. Dynamic TMIN Control Mode In addition to the automatic fan speed control mode described in the Automatic Fan Control Overview section, the ADT7473/ADT7473−1 has a mode that extends the basic automatic fan speed control loop. Dynamic TMIN www.onsemi.com 42 ADT7473 control allows the ADT7473/ADT7473−1 to intelligently adapt the system’s cooling solution for best system performance or lowest possible system acoustics, depending on user or design requirements. Use of dynamic TMIN control alleviates the need to design for worst-case conditions and significantly reduces system design and validation time. Worst-case Processor Power Consumption Designing for Worst-case Conditions The tendency is to design to data sheet maximums for peripheral components, again overcooling the system. This data sheet maximum does not necessarily reflect the true processor power consumption. Designing for worst-case CPU power consumption can result in a processor becoming overcooled (generating excess system noise). Worst-case Peripheral Power Consumption System design must always allow for worst-case conditions. In PC design, the worst-case conditions include, but are not limited to, the following: Worst-case Assembly Every system is unique because of manufacturing variations. Heat sinks may be loose fitting or slightly misaligned. Too much or too little thermal grease might be used, or variations in application pressure for thermal interface material could affect the efficiency of the thermal solution. Accounting for manufacturing variations in every system is difficult; therefore, the system must be designed for the worst-case conditions. Worst-case Altitude A computer can be operated at different altitudes. The altitude affects the relative air density, which alters the effectiveness of the fan cooling solution. For example, comparing 40°C air temperature at 10,000 feet to 20°C air temperature at sea level, relative air density is increased by 40%. This means that the fan can spin 40% slower and make less noise at sea level than at 10,000 feet while keeping the system at the same temperature at both locations. TA HEAT SINK Worst-case Fan INTEGRATED HEAT SPREADER GOOD CPU AIRFLOW CPU DRIVE BAYS FAN CPU DRIVE BAYS VENTS GOOD VENTING = GOOD AIR EXCHANGE qJA qTIMC PROCESSOR TTIM TJ Dynamic TMIN control mode builds on the basic automatic fan control loop by adjusting the TMIN value based on system performance and measured temperature. This is important because, instead of designing for the worst case, the system thermals can be defined as operating zones. The ADT7473/ADT7473−1 can self-adjust its fan control loop to maintain either an operating zone temperature or a system target temperature. For example, it can be specified that the ambient temperature in a system should be maintained at 50°C. If the temperature is below 50°C, the fans might not need to run, or might run very slowly. If the temperature is higher than 50°C, the fans need to throttle up. The challenge presented by any thermal design is finding the right settings to suit the system’s fan control solution. This can involve designing for the worst case, followed by weeks of system thermal characterization, and finally fan acoustic optimization (for psycho-acoustic reasons). POWER SUPPLY POOR CPU AIRFLOW TC Dynamic TMIN Control Overview FAN VENTS qCTIM Although a design usually accounts for worst-case conditions in all these cases, the actual system is almost never operated at worst-case conditions. The alternative to designing for the worst case is to use the dynamic TMIN control function. I/O CARDS POWER SUPPLY qCA qCS Figure 65. Thermal Model The same motherboard can be used in a number of different chassis configurations. The design of the chassis and the physical location of fans and components determine the system thermal characteristics. Moreover, for a given chassis, the addition of add-in cards, cables, or other system configuration options can alter the system airflow and reduce the effectiveness of the system cooling solution. The cooling solution can also be inadvertently altered by the end user. (For example, placing a computer against a wall can block the air ducts and reduce system airflow.) I/O CARDS TTIM qJTIM SUBSTRATE EPOXY THERMAL INTERFACE MATERIAL Worst-case Chassis Airflow FAN TS qTIMS THERMAL INTERFACE MATERIAL Due to manufacturing tolerances, fan speeds in RPM are normally quoted with a tolerance of ±20%. The designer needs to assume that the fan RPM can be 20% below tolerance. This translates to reduced system airflow and elevated system temperature. Note that fans 20% out of tolerance can negatively impact system acoustics because they run faster and generate more noise. VENTS qSA POOR VENTING = POOR AIR EXCHANGE Figure 64. Chassis Airflow Issues www.onsemi.com 43 ADT7473 Getting the most benefit from the automatic fan control mode involves characterizing the system to find the best TMIN and TRANGE settings for the control loop, and the best PWMMIN value for the quietest fan speed setting. Using the ADT7473/ADT7473−1’s dynamic TMIN control mode, however, shortens the characterization time and alleviates tweaking the control loop settings because the device can self-adjust during system operation. Dynamic TMIN control mode is operated by specifying the operating zone temperatures required for the system. Associated with this control mode are three operating point registers, one for each temperature channel. This allows the system thermal solution to be broken down into distinct thermal zones. For example, CPU operating temperature is 70°C, VRM operating temperature is 80°C, and ambient operating temperature is 50°C. The ADT7473/ADT7473−1 dynamically alters the control solution to maintain each zone temperature as closely as possible to its target operating point. Table 49 provides a brief description of each parameter. Table 49. TMIN CONTROL LOOP PARAMETERS Parameter Table 48. OPERATING POINT REGISTERS Register Description Remote 1 Operating Point 0xA4 (100°C) 0x34 Local Temp. Operating Point 0xA4 (100°C) 0x35 Remote 2 Operating Point 0xA4 (100°C) THIGH If the temperature exceeds the THIGH limit, an error flag is set in a status register and an SMBALERT interrupt can be generated. TMIN The temperature at which the fan turns on under automatic fan speed control. Operating Point The target temperature for a particular temperature zone. The ADT7473/ADT7473−1 attempts to maintain system temperature at about the operating point by adjusting the TMIN parameter of the control loop. TTHERM If the temperature exceeds this critical limit, the fans can be run at 100% for maximum cooling. TRANGE Programs the PWM duty cycle vs. temperature control slope. Step 9: Operating Points for Temperature Channels PWM DUTY CYCLE The operating point for each temperature channel is the optimal temperature for that thermal zone. The hotter each zone is allowed to be, the quieter the system, because the fans are not required to run as fast. The ADT7473/ ADT7473−1 increases or decreases fan speeds as necessary to maintain the operating point temperature, allowing for system-to-system variation and removing the need for worst-case design. If a sensible operating point value is chosen, any TMIN value can be selected in the system characterization. If the TMIN value is too low, the fans run sooner than required, and the temperature is below the operating point. In response, the ADT7473/ADT7473−1 increases TMIN to keep the fans off longer and to allow the temperature zone to get closer to the operating point. Likewise, too high a TMIN value causes the operating point to be exceeded, and in turn, the ADT7473/ADT7473−1 reduces TMIN to turn the fans on sooner to cool the system. TEMPERATURE TTHERM THIGH If the temperature drops below the TLOW limit, an error flag is set in a status register and an SMBALERT interrupt can be generated. Because the dynamic TMIN control mode is a basic extension of the automatic fan control mode, program the automatic fan control mode parameters first, as described in the Step 1: Hardware Configuration section to the Step 8: THYST for Temperature Channels section, then proceed with dynamic TMIN control mode programming. Figure 66 shows an overview of the parameters that affect the operation of the dynamic TMIN control loop. TMIN OPERATING POINT TLOW Dynamic TMIN Control Programming Default 0x33 TLOW Description TRANGE Figure 66. Dynamic TMIN Control Loop www.onsemi.com 44 ADT7473 Programming Operating Point Registers Table 50. OPERATING POINT REGISTERS There are three operating point registers, one for each temperature channel. These 8-bit registers allow the operating point temperatures to be programmed with 1°C resolution. Register THERMAL CALIBRATION 0xA4 (100°C) 0x34 Local Operating Point 0xA4 (100°C) 0x35 Remote 2 Operating Point 0xA4 (100°C) OPERATING POINT PWM MIN 100% LOCAL = VRM TEMP TRANGE 0% PWM MIN THERMAL CALIBRATION S TRANGE TACHOMETER2 MEASUREMENT RAMP CONTROL (ACOUSTIC ENHANCEMENT) 100% TMIN TACHOMETER1 MEASUREMENT RAMP CONTROL (ACOUSTIC ENHANCEMENT) S MUX TMIN PWM GENERATOR PWM1 0% THERMAL CALIBRATION REMOTE2 = CPU TEMP PWM CONFIG RAMP CONTROL (ACOUSTIC ENHANCEMENT) S TRANGE Default Remote 1 Operating Point PWM MIN 100% TMIN Description 0x33 TACH1 PWM CONFIG PWM GENERATOR PWM CONFIG PWM2 TACH2 FRONT CHASSIS PWM GENERATOR TACHOMETER3 AND 4 MEASUREMENT 0% CPU FAN SINK PWM3 TACH3 REMOTE1 = AMBIENT TEMP REAR CHASSIS Figure 67. Operating Point Value Dynamically Adjusts Automatic Fan Control Settings Step 10: High and Low Limits for Temperature Channels Table 51. TEMPERATURE LIMIT REGISTERS Register The low limit defines the temperature at which the TMIN value starts to be increased, if temperature falls below this value. This has the net effect of reducing the fan speed, allowing the system to get hotter. An interrupt can be generated when the temperature drops below the low limit. The high limit defines the temperature at which the TMIN value starts to be reduced, if temperature increases above this value. This has the net effect of increasing fan speed to cool down the system. An interrupt can be generated when the temperature rises above the high limit. Description Default 0x4E Remote 1 Temperature Low Limit 0x01 0x4F Remote 1 Temperature High Limit 0x7F 0x50 Local Temperature Low Limit 0x01 0x51 Local Temperature High Limit 0x7F 0x52 Remote 2 Temperature Low Limit 0x01 0x53 Remote 2 Temperature High Limit 0x7F How Dynamic TMIN Control Works The basic premise is as follows: 1. Set the target temperature for the temperature zone, which could be, for example, the Remote 1 thermal diode. This value is programmed to the Remote 1 operating temperature register. Programming High and Low Limits There are six limit registers; a high limit and low limit are associated with each temperature channel. These 8-bit registers allow the high and low limit temperatures to be programmed with 1°C resolution. www.onsemi.com 45 ADT7473 2. As the temperature in that zone (Remote 1 temperature) rises toward and exceeds the operating point temperature, TMIN is reduced, and the fan speed increases. 3. As the temperature drops below the operating point temperature, TMIN is increased, and the fan speed is reduced. WAIT n MONITORING CYCLES CURRENT TEMPERATURE MEASUREMENT T1(n) However, the loop operation is not as simple as described in these steps. A number of conditions govern the situations in which TMIN can increase or decrease. IS T1(n) − T1(n − 1) ≤ 0.255C YES IS T1(n) - T1(n - 1) = 0.5 - 0.755C IS T1(n) - T1(n - 1) = 1.0 - 1.755C IS T1(n) - T1(n - 1) > 2.05C Long Cycle 8 cycles 1 sec 16 cycles 2 sec 001 16 cycles 2 sec 32 cycles 4 sec 010 32 cycles 4 sec 64 cycles 8 sec DECREASE TMIN BY 15C DECREASE TMIN BY 25C DECREASE TMIN BY 45C Figure 69 shows the steps taken during the long cycle. WAIT 2n MONITORING CYCLES CURRENT TEMPERATURE MEASUREMENT T1(n) OPERATING POINT TEMPERATURE OP1 IS T1(n) > OP1 YES DECREASE TMIN BY 15C NO IS T1(n) < LOW TEMP LIMIT AND TMIN < HIGH TEMP LIMIT YES AND TMIN < OP1 AND T1(n) > TMIN Secs 000 DO NOTHING (SYSTEM IS COOLING OFF FOR CONSTANT) Figure 68. Short Cycle Steps Table 52. CYCLE BIT ASSIGNMENTS Secs DO NOTHING NO The ADT7473/ADT7473−1 implements two loops: a short cycle and a long cycle. The short cycle takes place every n monitoring cycles. The long cycle takes place every 2n monitoring cycles. The value of n is programmable for each temperature channel. The bits are located at the following register locations: Remote 1 = CYR1 = Bits <2:0> of Dynamic TMIN Control Register 2 (0x37). Local = CYL = Bits <5:3> of Dynamic TMIN Control Register 2 (0x37). Remote 2 = CYR2 = Bits <7:6> of Dynamic TMIN Control Register 2 (0x37) and Bit 0 of Dynamic TMIN Control Register 1 (0x36). Short Cycle NO YES PREVIOUS TEMPERATURE MEASUREMENT T1 (n − 1) Short Cycle and Long Cycle Code IS T1(n) > (OP1 − HYS) OPERATING POINT TEMPERATURE OP1 INCREASE TMIN BY 15C NO DO NOT CHANGE 011 64 cycles 8 sec 128 cycles 16 sec 100 128 cycles 16 sec 256 cycles 32 sec Figure 69. Long Cycle Steps 101 256 cycles 32 sec 512 cycles 64 sec 110 512 cycles 64 sec 1024 cycles 128 sec 111 1024 cycles 128 sec 2048 cycles 256 sec The following examples illustrate some of the circumstances that might cause TMIN to increase, decrease, or stay the same. Example 1: Normal Operation − No TMIN Adjustment Care should be taken when choosing the cycle time. A long cycle time means that TMIN is updated less often. If your system has very fast temperature transients, the dynamic TMIN control loop is always lagging. If a cycle time is chosen that is too fast, the full benefit of changing TMIN might not be realized and needs to change again on the next cycle; in effect, it is overshooting. It is necessary to carry out some calibration to identify the most suitable response time. Figure 68 shows the steps taken during the short cycle. • If measured temperature never exceeds the • programmed operating point minus the hysteresis temperature, then TMIN is not adjusted; that is, it remains at its current setting. If measured temperature never drops below the low temperature limit, then TMIN is not adjusted. www.onsemi.com 46 ADT7473 Example 3: Increase TMIN Cycle THERM LIMIT HIGH TEMP LIMIT OPERATING POINT When the temperature drops below the low temperature limit, TMIN can increase in the long cycle. Increasing TMIN has the effect of running the fan slower and, therefore, quieter. The long cycle diagram in Figure 69 shows the conditions required for TMIN to increase. A quick summary of those conditions and the reasons they need to be true follows. TMIN can increase if: • The measured temperature falls below the low temperature limit. This means the user must choose the low limit carefully. It should not be so low that the temperature never falls below it because TMIN would never increase, and the fans would run faster than necessary. • TMIN is below the high temperature limit. TMIN is never allowed to increase above the high temperature limit. As a result, the high limit should be sensibly chosen because it determines how high TMIN can go. • TMIN is below the operating point temperature. TMIN should never be allowed to increase above the operating point temperature because the fans would not switch on until the temperature rose above the operating point. • The temperature is above TMIN. The dynamic TMIN control is turned off below TMIN. HYSTERESIS ACTUAL TEMP LOW TEMP LIMIT TMIN Figure 70. Temperature Between the Operating Point and the Low Temperature Limit Because neither the operating point minus the hysteresis temperature nor the low temperature limit has been exceeded, the TMIN value is not adjusted, and the fan runs at a speed determined by the fixed TMIN and TRANGE values defined in the automatic fan speed control mode. Example 2: Operating Point Exceeded − TMIN Reduced When the measured temperature is below the operating point temperature minus the hysteresis, TMIN remains the same. Once the temperature exceeds the operating temperature minus the hysteresis (OP − Hyst), TMIN starts to decrease. This occurs during the short cycle (see Figure 68). The rate at which TMIN decreases depends on the programmed value of n. It also depends on how much the temperature has increased between this monitoring cycle and the last monitoring cycle; that is, if the temperature has increased by 1°C, then TMIN is reduced by 2°C. Decreasing TMIN has the effect of increasing the fan speed, thus providing more cooling to the system. If the temperature slowly increases only in the range (OP − Hyst), that is, ≤0.25°C per short monitoring cycle, then TMIN does not decrease. This allows small changes in temperature in the desired operating zone without changing TMIN. The long cycle makes no change to TMIN in the temperature range (OP − Hyst) because the temperature has not exceeded the operating temperature. Once the temperature exceeds the operating temperature, the long cycle causes TMIN to be reduced by 1°C every long cycle while the temperature remains above the operating temperature. This takes place in addition to the decrease in TMIN that occurs due to the short cycle. In Figure 71, because the temperature is increasing at a rate ≤0.25°C per short cycle, no reduction in TMIN takes place during the short cycle. Once the temperature falls below the operating temperature, TMIN stays the same. Even when the temperature starts to increase slowly, TMIN stays the same because the temperature increases at a rate ≤0.25°C per cycle. THERM LIMIT HIGH TEMP LIMIT OPERATING POINT HYSTERESIS ACTUAL TEMP NO CHANGE IN TMIN HERE DUE TO ANY CYCLE BECAUSE T1(n) - T1 (n - 1) ≤ 0.255C AND T1(n) < OP = > T MIN STAYS THE SAME TMIN LOW TEMP LIMIT DECREASE HERE DUE TO SHORT CYCLE ONLY T1(n) - T1 (n - 1) = 0.55C OR 0.755C = > TMIN DECREASES BY 15C EVERY SHORT CYCLE DECREASE HERE DUE TO LONG CYCLE ONLY T1(n) - T1 (n - 1) ≤ 0.255C AND T1(n) > OP = > T MIN DECREASES BY 15C EVERY LONG CYCLE Figure 71. Effect of Exceeding Operating Point Minus Hysteresis Temperature www.onsemi.com 47 ADT7473 the Pentium® 4 is connected to the THERM input of the ADT7473/ADT7473−1. The operating point for the processor can be determined by allowing the current temperature to be copied to the operating point register when the PROCHOT output pulls the THERM input low on the ADT7473/ADT7473−1. This gives the maximum temperature at which the Pentium® 4 can run before clock modulation occurs. Figure 72 shows how TMIN increases when the current temperature is above TMIN and below the low temperature limit, and TMIN is below the high temperature limit and below the operating point. Once the temperature rises above the low temperature limit, TMIN stays the same. THERM LIMIT HIGH TEMP LIMIT OPERATING POINT LOW TEMP LIMIT Enabling the THERM Trip Point as the Operating Point HYSTERESIS Bits <4:2> of Dynamic TMIN Control Register 1 (0x36) enable/disable THERM monitoring to program the operating point. ACTUAL TEMP Dynamic TMIN Control Register 1 (0x36) TMIN Bit <4> PHTR2 = 1, copies the Remote 2 current temperature to the Remote 2 operating point register, if THERM is asserted. The operating point contains the temperature at which THERM is asserted. This allows the system to run as quietly as possible without affecting system performance. PHTR2 = 0, ignores any THERM assertions. The Remote 2 operating point register reflects its programmed value. Bit <3> PHTL = 1, copies the local current temperature to the local temperature operating point register if THERM is asserted. The operating point contains the temperature at which THERM is asserted. This allows the system to run as quietly as possible without affecting system performance. PHTL = 0, ignores any THERM assertions. The local temperature operating point register reflects its programmed value. Bit <2> PHTR1 = 1, copies the Remote 1 current temperature to the Remote 1 operating point register if THERM is asserted. The operating point contains the temperature at which THERM is asserted. This allows the system to run as quietly as possible without affecting system performance. PHTR1 = 0, ignores any THERM assertions. The Remote 1 operating point register reflects its programmed value. Figure 72. Increasing TMIN for Quieter Operation Example 4: Preventing TMIN from Reaching Full Scale Because TMIN is dynamically adjusted, it is undesirable for TMIN to reach full scale (127°C) because the fan would never switch on. As a result, TMIN is allowed to vary only within a specified range: • The lowest possible value for TMIN is −127°C (twos complement mode) or −64°C (Offset 64 mode). • TMIN cannot exceed the high temperature limit. • If the temperature is below TMIN, the fan is switched off or runs at minimum speed and dynamic TMIN control is disabled. THERM LIMIT OPERATING POINT LOW TEMP LIMIT HYSTERESIS ACTUAL TEMP HIGH TEMP LIMIT TMIN TMIN PREVENTED FROM INCREASING Figure 73. TMIN Adjustments Limited by the High Temperature Limit Enabling Dynamic TMIN Control Mode Bits <7:5> of the Dynamic TMIN Control Register 1 (0x36) enable/disable dynamic TMIN control on the temperature channels. Step 11: Monitoring THERM Using the operating point limit ensures that the dynamic TMIN control mode operates in the best possible acoustic position while ensuring that the temperature never exceeds the maximum operating temperature. Using the operating point limit allows TMIN to be independent of system-level issues because of its self-corrective nature. In PC design, the operating point for the chassis is usually the worst-case internal chassis temperature. The optimal operating point for the processor is determined by monitoring the thermal monitor in the Intel® Pentium® 4 processor. To do this, the PROCHOT output of Dynamic TMIN Control Register 1 (0x36) Bit <7> R2T = 1, enables dynamic TMIN control on the Remote 2 temperature channel. The chosen TMIN value is dynamically adjusted based on the current temperature, operating point, and high and low limits for this zone. R2T = 0, disables dynamic TMIN control. The TMIN value chosen is not adjusted and the channel behaves as described in the Automatic Fan Control Overview section. www.onsemi.com 48 ADT7473 Bit <6> LT = 1, enables dynamic TMIN control on the local temperature channel. The chosen TMIN value is dynamically adjusted based on the current temperature, operating point, and high and low limits for this zone. LT = 0, disables dynamic TMIN control. The TMIN value chosen is not adjusted and the channel behaves as described in the Automatic Fan Control Overview section. Bit <5> R1T = 1, enables dynamic TMIN control on the Remote 1 temperature channel. The chosen TMIN value is dynamically adjusted based on the current temperature, operating point, and high and low limits for this zone. R1T = 0, disables dynamic TMIN control. The TMIN value chosen is not adjusted, and the channel behaves as described in the Automatic Fan Control Overview section. mechanical engineer evaluating best settings for the system. Having determined the optimal settings for the thermal solution, the engineer can adjust the system acoustics. The goal is to implement a system that is acoustically pleasing without causing user annoyance due to fan cycling. It is important to realize that although a system might pass an acoustic noise requirement specification (for example, 36 dB), if the fan is annoying, it fails the consumer test. Approaches to System Acoustic Enhancement There are two different approaches to implementing system acoustic enhancement: temperature-centric and fan-centric. The temperature-centric approach involves smoothing transient temperatures as they are measured by a temperature source (for example, Remote 1 temperature). The temperature values used to calculate the PWM duty cycle values are smoothed, reducing fan speed variation. However, this approach causes an inherent delay in updating fan speed and causes the thermal characteristics of the system to change. It also causes the system fans to stay on longer than necessary because the fan’s reaction is merely delayed. The user has no control over noise from different fans driven by the same temperature source. Consider, for example, a system in which control of a CPU cooler fan (on PWM1) and a chassis fan (on PWM2) use Remote 1 temperature. Because the Remote 1 temperature is smoothed, both fans are updated at exactly the same rate. If the chassis fan is much louder than the CPU fan, there is no way to improve its acoustics without changing the thermal solution of the CPU cooling fan. Enhancing System Acoustics Automatic fan speed control mode reacts instantaneously to changes in temperature; that is, the PWM duty cycle responds immediately to temperature change. Any impulses in temperature can cause an impulse in fan noise. For psycho-acoustic reasons, the ADT7473/ADT7473−1 can prevent the PWM output from reacting instantaneously to temperature changes. Enhanced acoustic mode controls the maximum change in PWM duty cycle at a given time. The objective is to prevent the fan from cycling up and down, annoying the user. Acoustic Enhancement Mode Overview Figure 74 gives a top-level overview of the automatic fan control circuitry on the ADT7473/ADT7473−1 and shows where acoustic enhancement fits in. Acoustic enhancement is intended as a post design tweak made by a system or ACOUSTIC ENHANCEMENT THERMAL CALIBRATION PWM MIN 100% S TMIN REMOTE2 = CPU TEMP TRANGE PWM MIN 100% S MUX LOCAL = VRM TEMP TRANGE 0% PWM MIN THERMAL CALIBRATION 100% S TMIN TRANGE RAMP CONTROL (ACOUSTIC ENHANCEMENT) PWM GENERATOR PWM1 0% THERMAL CALIBRATION TMIN PWM CONFIG TACHOMETER1 MEASUREMENT RAMP CONTROL (ACOUSTIC ENHANCEMENT) TACHOMETER2 MEASUREMENT RAMP CONTROL (ACOUSTIC ENHANCEMENT) TACH1 PWM CONFIG PWM GENERATOR PWM CONFIG PWM2 TACH2 FRONT CHASSIS PWM GENERATOR TACHOMETER3 AND 4 MEASUREMENT 0% CPU FAN SINK PWM3 TACH3 REMOTE1 = AMBIENT TEMP Figure 74. Acoustic Enhancement Smoothes Fan Speed Variations Under Automatic Fan Speed Control www.onsemi.com 49 REAR CHASSIS ADT7473 The fan-centric approach to system acoustic enhancement controls the PWM duty cycle, driving the fan at a fixed rate (for example, 6%). Each time the PWM duty cycle is updated, it is incremented by a fixed 6%. As a result, the fan ramps smoothly to its newly calculated speed. If the temperature starts to drop, the PWM duty cycle immediately decreases by 6% at every update. Therefore, the fan ramps smoothly up or down without inherent system delay. Consider, for example, controlling the same CPU cooler fan (on PWM1) and chassis fan (on PWM2) using Remote 1 temperature. The TMIN and TRANGE settings have already been defined in automatic fan speed control mode, that is, thermal characterization of the control loop has been optimized. Here, the chassis fan is noisier than the CPU cooling fan. Using the fan-centric approach, PWM2 can be placed into acoustic enhancement mode independently of PWM1. The acoustics of the chassis fan can, therefore, be adjusted without affecting the acoustic behavior of the CPU cooling fan, even though both fans are controlled by Remote 1 temperature. The fan-centric approach is how acoustic enhancement works on the ADT7473/ ADT7473−1. If the PWM duty cycle value needs to be decreased, it is decreased by eight time slots. Figure 76 shows how the enhanced acoustics mode algorithm operates. The enhanced acoustics mode algorithm calculates a new PWM duty cycle based on the temperature measured. If the new PWM duty cycle value is greater than the previous PWM value, then the previous PWM duty cycle value is incremented by either 1, 2, 3, 5, 8, 12, 24, or 48 time slots, depending on the settings of the enhanced acoustics registers. If the new PWM duty cycle value is less than the previous PWM value, the previous PWM duty cycle is decremented by 1, 2, 3, 5, 8, 12, 24, or 48 time slots. Each time the PWM duty cycle is incremented or decremented, its value is stored as the previous PWM duty cycle for the next comparison. A ramp rate of 1 corresponds to one time slot, which is 1/255 of the PWM period. In enhanced acoustics mode, incrementing or decrementing by 1 changes the PWM output by 1/255 × 100%. READ TEMPERATURE CALCULATE NEW PWM DUTY CYCLE Enabling Acoustic Enhancement for Each PWM Output Enhanced acoustics Register 1 (0x62) Bit 3 = 1, enables acoustic enhancement on PWM1 output IS NEW PWM VALUE > PREVIOUS VALUE? Enhanced acoustics Register 2 (0x63) Bit 7 = 1, enables acoustic enhancement on PWM2 output Bit 3 = 1, enables acoustic enhancement on PWM3 output Effect of Ramp Rate on Enhanced Acoustics Mode DECREMENT PREVIOUS PWM VALUE BY RAMP RATE YES The PWM signal driving the fan has a period, T, given by the PWM drive frequency, f, because T = 1/f. For a given PWM period, T, the PWM period is subdivided into 255 equal time slots. One time slot corresponds to the smallest possible increment in the PWM duty cycle. A PWM signal of 33% duty cycle is, therefore, high for 1/3 × 255 time slots and low for 2/3 × 255 time slots. Therefore, a 33% PWM duty cycle corresponds to a signal that is high for 85 time slots and low for 170 time slots. INCREMENT PREVIOUS PWM VALUE BY RAMP RATE Figure 76. Enhanced Acoustics Algorithm Step 12: Ramp Rate for Acoustic Enhancement The optimal ramp rate for acoustic enhancement can be found through system characterization after the thermal optimization has been finished. The effect of each ramp rate should be logged, if possible, to determine the best setting for a given solution. PWM_OUT 33% DUTY CYCLE 85 TIME SLOTS NO 170 TIME SLOTS Enhanced Acoustics Register 1 (0x62) PWM OUTPUT (ONE PERIOD) = 255 TIME SLOTS Bits <2:0> ACOU, select the ramp rate for PWM1. 000 = 1 time slot = 35 sec 001 = 2 time slots = 17.6 sec 010 = 3 time slots = 11.8 sec 011 = 5 time slots = 7 sec 100 = 8 time slots = 4.4 sec 101 = 12 time slots = 3 sec 110 = 24 time slots = 1.6 sec 111 = 48 time slots = 0.8 sec Figure 75. 33% PWM Duty Cycle Represented in Time Slots The ramp rates in the enhanced acoustics mode are selectable from the values 1, 2, 3, 5, 8, 12, 24, and 48. The ramp rates are discrete time slots. For example, if the ramp rate is 8, then eight time slots are added to the PWM high duty cycle each time the PWM duty cycle needs to be increased. www.onsemi.com 50 ADT7473 Enhanced Acoustics Register 2 (0x63) Figure 78 shows how changing the ramp rate from 48 to 8 affects the control loop. The overall response of the fan is slower. Because the ramp rate is reduced, it takes longer for the fan to achieve full running speed. In this case, it takes approximately 4.4 seconds for the fan to reach full speed. RTEMP(°C) 100 RTEMP(°C) 80 80 60 PWM DUTY CYCLE (%) 60 40 40 20 20 0 0 0 4.4 TIME (s) Figure 78. Enhanced Acoustics Mode with Ramp Rate = 8 Figure 79 shows the PWM output response for a ramp rate of 2. In this instance, the fan takes about 17.6 seconds to reach full running speed. 140 120 RTEMP(°C) 120 RTEMP(°C) 100 80 80 60 60 PWM DUTY CYCLE (%) 40 120 20 100 0 40 PWM CYCLE (%) 100 20 RTEMP(°C) 120 0 100 80 80 60 60 PWM CYCLE (%) 40 40 PWM CYCLE (%) 0 RTEMP(°C) 120 100 Another way to view the ramp rates is to measure the time it takes for the PWM output to ramp up from 0% to 100% duty cycle for an instantaneous change in temperature. This can be tested by putting the ADT7473/ADT7473−1 into manual mode and changing the PWM output from 0% to 100% PWM duty cycle. The PWM output takes 35 seconds to reach 100% when a ramp rate of 1 time slot is selected. Figure 77 shows remote temperature plotted against PWM duty cycle for enhanced acoustics mode. The ramp rate is set to 48, which corresponds to the fastest ramp rate. Assume that a new temperature reading is available every 115 ms. With these settings, it takes approximately 0.76 seconds to go from 33% duty cycle to 100% duty cycle (full speed). Even though the temperature increases very rapidly, the fan ramps up to full speed gradually. 140 140 120 PWM CYCLE (%) Bits <2:0> ACOU3, select the ramp rate for PWM3. 000 = 1 time slot = 35 sec 001 = 2 time slots = 17.6 sec 010 = 3 time slots = 11.8 sec 011 = 5 time slots = 7 sec 100 = 8 time slots = 4.4 sec 101 = 12 time slots = 3 sec 110 = 24 time slots = 1.6 sec 111 = 48 time slots = 0.8 sec Bits <6:4> ACOU2, select the ramp rate for PWM2. 000 = 1 time slot = 35 sec 001 = 2 time slots = 17.6 sec 010 = 3 time slots = 11.8 sec 011 = 5 time slots = 7 sec 100 = 8 time slots = 4.4 sec 101 = 12 time slots = 3 sec 110 = 24 time slots = 1.6 sec 111 = 48 time slots = 0.8 sec Figure 79. Enhanced Acoustics Mode with Ramp Rate = 2 Figure 80 shows how the control loop reacts to temperature with the slowest ramp rate. The ramp rate is set to 1, while all other control parameters remain the same. With the slowest ramp rate selected, it takes 35 seconds for the fan to reach full speed. 20 20 0 0 TIME (s) TIME (s) 17.6 0 0.76 Figure 77. Enhanced Acoustics Mode with Ramp Rate = 48 www.onsemi.com 51 ADT7473 RTEMP(°C) 100 Slower Ramp Rates 120 The ADT7473/ADT7473−1 can be programmed for much longer ramp times by slowing the ramp rates. Each ramp rate can be slowed by a factor of 4. 100 80 RTEMP(°C) 140 80 60 60 40 40 PWM DUTY CYCLE (%) 20 0 0 TIME (s) PWM CYCLE (%) 120 PWM1 Configuration Register (0x5C) Bit <3> SLOW, 1 slows the ramp rate for PWM1 by 4. PWM2 Configuration Register (0x5D) Bit <3> SLOW, 1 slows the ramp rate for PWM2 by 4. 20 PWM3 Configuration Register (0x5E) 0 Bit <3> SLOW, 1 slows the ramp rate for PWM3 by 4. The following sections list the ramp-up times when the SLOW bit is set for each PWM output. 35 Figure 80. Enhanced Acoustics Mode with Ramp Rate = 1 Enhanced Acoustics Register 1 (0x62) As Figure 77 to Figure 80 show, the rate at which the fan reacts to temperature change is dependent on the ramp rate selected in the enhanced acoustics registers. The higher the ramp rate, the faster the fan reaches the newly calculated fan speed. 90 90 PWM DUTY CYCLE (%) 80 70 70 60 60 50 50 40 RTEMP(°C) 40 30 30 20 20 10 10 0 PWM CYCLE (%) RTEMP(°C) 80 Bits <2:0> ACOU, select the ramp rate for PWM1. 000 = 140 sec 001 = 70.4 sec 010 = 47.2 sec 011 = 28 sec 100 = 17.6 sec 101 = 12 sec 110 = 6.4 sec 111 = 3.2 sec Enhanced Acoustics Register 2 (0x63) Bits <2:0> ACOU3, select the ramp rate for PWM3. 000 = 140 sec 001 = 70.4 sec 010 = 47.2 sec 011 = 28 sec 100 = 17.6 sec 101 = 12 sec 110 = 6.4 sec 111 = 3.2 sec Bits <6:4> ACOU2, select the ramp rate for PWM2. 000 = 140 sec 001 = 70.4 sec 010 = 47.2 sec 011 = 28 sec 100 = 17.6 sec 101 = 12 sec 110 = 6.4 sec 111 = 3.2 sec 0 TIME (s) Figure 81. How Fan Reacts to Temperature Variations in Enhanced Acoustics Mode Figure 81 shows the behavior of the PWM output as temperature varies. As the temperature increases, the fan speed ramps up. Small drops in temperature do not affect the ramp-up function because the newly calculated fan speed is still higher than the previous PWM value. Enhanced acoustics mode allows the PWM output to be made less sensitive to temperature variations. This is dependent on the ramp rate selected and programmed into the enhanced acoustics registers. www.onsemi.com 52 ADT7473 Register Tables Table 53. ADT7473/ADT7473−1 REGISTERS Addr R/W Desc Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Lockable 0x21 R VCCP Reading 9 8 7 6 5 4 3 2 0x00 − 0x22 R VCC Reading 9 8 7 6 5 4 3 2 0x00 − 0x25 R Remote 1 Temp. 9 8 7 6 5 4 3 2 0x01 − 0x26 R Local Temp. 9 8 7 6 5 4 3 2 0x01 − 0x27 R Remote 2 Temp. 9 8 7 6 5 4 3 2 0x01 − 0x28 R TACH1 Low Byte 7 6 5 4 3 2 1 0 0x00 − 0x29 R TACH1 High Byte 15 14 13 12 11 10 9 8 0x00 − 0x2A R TACH2 Low Byte 7 6 5 4 3 2 1 0 0x00 − 0x2B R TACH2 High Byte 15 14 13 12 11 10 9 8 0x00 − 0x2C R TACH3 Low Byte 7 6 5 4 3 2 1 0 0x00 − 0x2D R TACH3 High Byte 15 14 13 12 11 10 9 8 0x00 − 0x2E R TACH4 Low Byte 7 6 5 4 3 2 1 0 0x00 − 0x2F R TACH4 High Byte 15 14 13 12 11 10 9 8 0x00 − 0x30 R/W PWM1 Current Duty Cycle 7 6 5 4 3 2 1 0 0x00/0 xFF − 0x31 R/W PWM2 Current Duty Cycle 7 6 5 4 3 2 1 0 0x00/0 xFF − 0x32 R/W PWM3 Current Duty Cycle 7 6 5 4 3 2 1 0 0x00/0 xFF − 0x33 R/W Remote 1 Operating Point 7 6 5 4 3 2 1 0 0xA4 Yes 0x34 R/W Local Temp Operating Point 7 6 5 4 3 2 1 0 0xA4 Yes 0x35 R/W Remote 2 Operating Point 7 6 5 4 3 2 1 0 0xA4 Yes 0x36 R/W Dynamic TMIN Control Reg. 1 R2T LT R1T PHTR2 PHTL PHTR1 VCCPLO CYR2 0x00 Yes 0x37 R/W Dynamic TMIN Control Reg. 2 CYR2 CYR2 CYL CYL CYL CYR1 CYR1 CYR1 0x00 Yes 0x38 R/W PWM1 Max Duty Cycle 7 6 5 4 3 2 1 0 0xFF − 0x39 R/W PWM2 Max Duty Cycle 7 6 5 4 3 2 1 0 0xFF − 0x3A R/W PWM3 Max Duty Cycle 7 6 5 4 3 2 1 0 0xFF − www.onsemi.com 53 ADT7473 Table 53. ADT7473/ADT7473−1 REGISTERS (continued) Addr R/W Desc Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Lockable 0x3D R Device ID Register 7 6 5 4 3 2 1 0 0x73 − 0x3E R Company ID Number 7 6 5 4 3 2 1 0 0x41 − 0x3F R Revision ID Register 7 6 5 4 3 2 1 0 0x68/0 x69 − 0x40 R/W Config. Register 1 ADT7473: RES ADT7473−1: Latch Reset TODIS FSPDIS Vx1 FSPD RDY LOCK STRT 0x01 Yes 0x41 R Interrupt Status Register 1 OOL R2T LT R1T RES VCC VCCP RES 0x00 − 0x42 R Interrupt Status Register 2 D2 D1 F4P FAN3 FAN2 FAN1 OVT ADT7473: RES ADT7473−1: THERM Limit Latch 0x00 − 0x46 R/W VCCP Low Limit 7 6 5 4 3 2 1 0 0x00 − 0x47 R/W VCCP High Limit 7 6 5 4 3 2 1 0 0xFF − 0x48 R/W VCC Low Limit 7 6 5 4 3 2 1 0 0x00 − 0x49 R/W VCC High Limit 7 6 5 4 3 2 1 0 0xFF − 0x4E R/W Remote 1 Temp. Low Limit 7 6 5 4 3 2 1 0 0x01 − 0x4F R/W Remote 1 Temp. High Limit 7 6 5 4 3 2 1 0 0xFF − 0x50 R/W Local Temp. Low Limit 7 6 5 4 3 2 1 0 0x01 − 0x51 R/W Local Temp. High Limit 7 6 5 4 3 2 1 0 0xFF − 0x52 R/W Remote 2 Temp. Low Limit 7 6 5 4 3 2 1 0 0x01 − 0x53 R/W Remote 2 Temp. High Limit 7 6 5 4 3 2 1 0 0xFF − 0x54 R/W TACH1 Minimum Low Byte 7 6 5 4 3 2 1 0 0xFF − 0x55 R/W TACH1 Minimum High Byte 15 14 13 12 11 10 9 8 0xFF − 0x56 R/W TACH2 Minimum Low Byte 7 6 5 4 3 2 1 0 0xFF − 0x57 R/W TACH2 Minimum High Byte 15 14 13 12 11 10 9 8 0xFF − 0x58 R/W TACH3 Minimum Low Byte 7 6 5 4 3 2 1 0 0xFF − 0x59 R/W TACH3 Minimum High Byte 15 14 13 12 11 10 9 8 0xFF − www.onsemi.com 54 ADT7473 Table 53. ADT7473/ADT7473−1 REGISTERS (continued) Addr R/W Desc Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Lockable 0x5A R/W TACH4 Minimum Low Byte 7 6 5 4 3 2 1 0 0xFF − 0x5B R/W TACH4 Minimum High Byte 15 14 13 12 11 10 9 8 0xFF − 0x5C R/W PWM1 Config. Register BHVR BHVR BHVR INV SLOW SPIN SPIN SPIN 0x82/0 x62 Yes 0x5D R/W PWM2 Config. Register BHVR BHVR BHVR INV SLOW SPIN SPIN SPIN 0x82/0 x62 Yes 0x5E R/W PWM3 Config. Register BHVR BHVR BHVR INV SLOW SPIN SPIN SPIN 0x82/0 x62 Yes 0x5F R/W Remote 1 TRANGE/ PWM 1 Frequency RANGE RANGE RANGE RANGE HF/LF Fan 1 FREQ FREQ FREQ 0xCC Yes 0x60 R/W Local TRANGE/ PWM 2 Frequency RANGE RANGE RANGE RANGE HF/LF Fan 2 FREQ FREQ FREQ 0xCC Yes 0x61 R/W Remote 2 TRANGE/ PWM 3 Frequency RANGE RANGE RANGE RANGE HF/LF Fan 3 FREQ FREQ FREQ 0xCC Yes 0x62 R/W Enhanced Acoustics Reg. 1 MIN3 MIN2 MIN1 SYNC EN1 ACOU ACOU ACOU 0x00 Yes 0x63 R/W Enhanced Acoustics Reg. 2 EN2 ACOU2 ACOU2 ACOU2 EN3 ACOU3 ACOU3 ACOU3 0x00 Yes 0x64 R/W PWM1 Min Duty Cycle 7 6 5 4 3 2 1 0 0x80 Yes 0x65 R/W PWM2 Min Duty Cycle 7 6 5 4 3 2 1 0 0x80 Yes 0x66 R/W PWM3 Min Duty Cycle 7 6 5 4 3 2 1 0 0x80 Yes 0x67 R/W Remote 1 Temp. TMIN 7 6 5 4 3 2 1 0 0x9A Yes 0x68 R/W Local Temp. TMIN 7 6 5 4 3 2 1 0 0x9A Yes 0x69 R/W Remote 2 Temp. TMIN 7 6 5 4 3 2 1 0 0x9A Yes 0x6A R/W Remote 1 THERM Temp. Limit 7 6 5 4 3 2 1 0 0xA4 Yes 0x6B R/W Local THERM Temp. Limit 7 6 5 4 3 2 1 0 0xA4 Yes 0x6C R/W Remote 2 THERM Temp. Limit 7 6 5 4 3 2 1 0 0xA4/0 xC8 Yes 0x6D R/W Remote 1 and Local Temp/TMIN Hysteresis HYSR1 HYSR1 HYSR1 HYSR1 HYSL HYSL HYSL HYSL 0x44 Yes 0x6E R/W Remote 2 Temp/TMIN Hysteresis HYSR2 HYSR2 HYSR2 HYRS2 RES RES RES RES 0x40 Yes 0x6F R/W XNOR Tree Test Enable RES RES RES RES RES RES RES XEN 0x00 Yes www.onsemi.com 55 ADT7473 Table 53. ADT7473/ADT7473−1 REGISTERS (continued) Addr R/W Desc Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Lockable 0x70 R/W Remote 1 Temp. Offset 7 6 5 4 3 2 1 0 0x00 Yes 0x71 R/W Local Temp. Offset 7 6 5 4 3 2 1 0 0x00 Yes 0x72 R/W Remote 2 Temp. Offset 7 6 5 4 3 2 1 0 0x00 Yes 0x73 R/W Config. Register 2 SHDN CONV ATTN AVG FAN3 Detect FAN2 Detect FAN1 Detect FAN Presence DT 0x00 Yes 0x74 R/W Interrupt Mask Register 1 OOL R2T LT R1T RES VCC VCCP RES 0x00 − 0x75 R/W Interrupt Mask Register 2 D2 D1 F4P FAN3 FAN2 FAN1 OVT RES 0x00 − 0x76 R Extended Resolution 1 RES RES VCC VCC VCCP VCCP RES RES 0x00 − 0x77 R Extended Resolution 2 TDM2 TDM2 LTMP LTMP TDM1 TDM1 RES RES 0x00 − 0x78 R/W Config. Register 3 DC4 DC3 DC2 DC1 FAST BOOST THERM ALERT Enable 0x00 Yes 0x79 R THERM Timer Status Register TMR TMR TMR TMR TMR TMR TMR ASRT/ TMRO 0x00 − 0x7A R/W THERM Timer Limit Register LIMT LIMT LIMT LIMT LIMT LIMT LIMT LIMT 0x00 − 0x7B R/W TACH Pulses per Revolution FAN4 FAN4 FAN3 FAN3 FAN2 FAN2 FAN1 FAN1 0X55 − 0x7C R/W Config. Register 5 R2 THERM Local THERM R1 THERM ADT7473: RES ADT7473−1: THERM HYSTR GPIOP GPIOD Temp Offset TWOS COMPL ADT 7473: 0x00 Yes 0x7D R/W Config. Register 4 RES RES BpAtt VCCP ADT7473: RES ADT7473−1: THERM_LATCH CONFIG Max/ Full on THERM THERM Disable PIN9 FUNC PIN9 FUNC 0x00 Yes 0x7E R Test Register 1 DO NOT WRITE TO THESE REGISTERS 0x00 Yes 0x7F R Test Register 2 DO NOT WRITE TO THESE REGISTERS 0x00 Yes 0x80 R Test Register 3 DO NOT WRITE TO THESE REGISTERS 0x10 Yes Table 54. VOLTAGE READING REGISTERS (POWER-ON DEFAULT = 0X00) (Note 1) Register Address R/W Description 0x21 Read-only Reflects the voltage measurement at the VCCP input on Pin 14 (8 MSB of reading). (Note 2) 0x22 Read-only Reflects the voltage measurement at the VCC input on Pin 3 (8 MSB of reading). (Note 3) 1. If the extended resolution bits of these readings are also being read, the extended resolution registers (Register 0x76 and Register 0x77) must be read first. Once the extended resolution registers have been read, the associated MSB reading registers are frozen until read. Both the extended resolution registers and the MSB registers are frozen. 2. If VCCPLO (Bit 1 of the Dynamic TMIN Control Register 1, 0x36) is set, VCCP can control the sleep state of the ADT7473/ADT7473−1. 3. VCC (Pin 3) is the supply voltage for the ADT7473/ADT7473−1. www.onsemi.com 56 ADT7473 Table 55. TEMPERATURE READING REGISTERS (POWER-ON DEFAULT = 0X01) (Note 1 and 2) Register Address R/W 0x25 Read-only Remote 1 Temperature Reading (8 MSB of Reading) (Note 3 and 4) Description 0x26 Read-only Local Temperature Reading (8 MSB of Reading) 0x27 Read-only Remote 2 Temperature Reading (8 MSB of Reading) (Note 3 and 4) 1. These temperature readings can be in twos complement or Offset 64 format; this interpretation is determined by Bit 0 of Configuration Register 5 (0x7C). 2. If the extended resolution bits of these readings are also being read, the extended resolution registers (Register 0x76 and Register 0x77) must be read first. Once the extended resolution registers have been read, all associated MSB reading registers are frozen until read. Both the extended resolution registers and the MSB registers are frozen. 3. In twos complement mode, a temperature reading of −128°C (0x80) indicates a diode fault (open or short) on that channel. 4. In Offset 64 mode, a temperature reading of −64°C (0x00) indicates a diode fault (open or short) on that channel. Table 56. FAN TACHOMETER READING REGISTERS (POWER-ON DEFAULT = 0X00) (Note 1) Register Address R/W Description 0x28 Read-only TACH1 Low Byte 0x29 Read-only TACH1 High Byte 0x2A Read-only TACH2 Low Byte 0x2B Read-only TACH2 High Byte 0x2C Read-only TACH3 Low Byte 0x2D Read-only TACH3 High Byte 0x2E Read-only TACH4 Low Byte 0x2F Read-only TACH4 High Byte 1. These registers count the number of 11.11 ms periods (based on an internal 90 kHz clock) that occur between a number of consecutive fan TACH pulses (default = 2). The number of TACH pulses used to count can be changed using the TACH pulses per revolution register (Register 0x7B). This allows the fan speed to be accurately measured. Because a valid fan tachometer reading requires that two bytes are read, the low byte must be read first. Both the low and high bytes are then frozen until read. At power-on, these registers contain 0x0000 until the first valid fan TACH measurement is read into these registers. This prevents false interrupts from occurring while the fans are spinning up. A count of 0xFFFF indicates a fan is one of the following: • Stalled or blocked (object jamming the fan). • Failed (internal circuitry destroyed). • Not populated. (The ADT7473/ADT7473−1 expects to see a fan connected to each TACH. If a fan is not connected to that TACH, its TACH minimum high and low bytes should be set to 0xFFFF.) • Alternate function, for example, TACH4 reconfigured as THERM pin. Table 57. CURRENT PWM DUTY CYCLE REGISTERS (ADT7473 POWER-ON DEFAULT = 0X00, ADT7473−1 POWER-ON DEFAULT = 0XFF) (Note 1) Register Address R/W 0x30 R/W PWM1 Current Duty Cycle (0% to 100% Duty Cycle = 0x00 to 0xFF) 0x31 R/W PWM2 Current Duty Cycle (0% to 100% Duty Cycle = 0x00 to 0xFF) 0x32 R/W PWM3 Current Duty Cycle (0% to 100% Duty Cycle = 0x00 to 0xFF) Description 1. These registers reflect the PWM duty cycle driving each fan at any given time. When in automatic fan speed control mode, the ADT7473/ADT7473−1 reports the PWM duty cycles back through these registers. The PWM duty cycle values vary according to temperature in automatic fan speed control mode. During fan startup, these registers report back 0x00. In software mode, the PWM duty cycle outputs can be set to any duty cycle value by writing to these registers. Table 58. OPERATING POINT REGISTERS (POWER-ON = 0XA4) (Note 1, 2 and 3) Register Address R/W (Note 3) Description 0x33 R/W Remote 1 Operating Point Register (Default = 100°C) 0x34 R/W Local Temperature Operating Point Register (Default = 100°C) 0x35 R/W Remote 2 Operating Point Register (Default = 100°C) 1. These registers set the target operating point for each temperature channel when the dynamic TMIN control feature is enabled. 2. The fans being controlled are adjusted to maintain temperature about an operating point. 3. These registers become read-only when the Configuration Register 1 Lock bit is set to 1. Any subsequent attempts to write to these registers fail. www.onsemi.com 57 ADT7473 Table 59. REGISTER 0X36 − DYNAMIC TMIN CONTROL REGISTER 1 (POWER-ON DEFAULT = 0X00) (Note 1) Bit No. Mnemonic R/W Description <0> CYR2 R/W MSB of 3-bit Remote 2 cycle value. The other two bits of the code reside in Dynamic TMIN Control Register 2 (Reg. 0x37). These three bits define the delay time between making subsequent TMIN adjustments in the control loop, in terms of the number of monitoring cycles. The system has associated thermal time constants that need to be found to optimize the response of fans and the control loop. <1> VCCPLO R/W VCCPLO = 1. When the power is supplied from 3.3 V STANDBY and the core voltage (VCCP) drops below its VCCP low limit value (Register 0x46), the following occurs: Status Bit 1 in Interrupt Status Register 1 is set. SMBALERT is generated, if enabled. PROCHOT monitoring is disabled. Dynamic TMIN control is disabled. The device is prevented from entering shutdown. Everything is re-enabled once VCCP increases above the VCCP low limit. <2> PHTR1 R/W PHTR1 = 1 copies the Remote 1 current temperature to the Remote 1 operating point register if THERM is asserted. The operating point contains the temperature at which THERM is asserted, allowing the system to run as quietly as possible without affecting system performance. PHTR1 = 0 ignores any THERM assertions on the THERM pin. The Remote 1 operating point register reflects its programmed value. <3> PHTL R/W PHTL = 1 copies the local channel’s current temperature to the local operating point register if THERM is asserted. The operating point contains the temperature at which THERM is asserted. This allows the system to run as quietly as possible without affecting system performance. PHTL = 0 ignores any THERM assertions on the THERM pin. The local temperature operating point register reflects its programmed value. <4> PHTR2 R/W PHTR2 = 1 copies the Remote 2 current temperature to the Remote 2 operating point register if THERM is asserted. The operating point contains the temperature at which THERM is asserted, allowing the system to run as quietly as possible without affecting system performance. PHTR2 = 0 ignores any THERM assertions on the THERM pin. The Remote 2 operating point register reflects its programmed value. <5> R1T R/W R1T = 1 enables dynamic TMIN control on the Remote 1 temperature channel. The chosen TMIN value is dynamically adjusted based on the current temperature, operating point, and high and low limits for this zone. R1T = 0 disables dynamic TMIN control. The TMIN value chosen is not adjusted, and the channel behaves as described in the Fan Speed Control section. <6> LT R/W LT = 1 enables dynamic TMIN control on the local temperature channel. The chosen TMIN value is dynamically adjusted based on the current temperature, operating point, and high and low limits for this zone. LT = 0 disables dynamic TMIN control. The TMIN value chosen is not adjusted, and the channel behaves as described in the Fan Speed Control section. <7> R2T R/W R2T = 1 enables dynamic TMIN control on the Remote 2 temperature channel. The chosen TMIN value is dynamically adjusted based on the current temperature, operating point, and high and low limits for this zone. R2T = 0 disables dynamic TMIN control. The TMIN value chosen is not adjusted and the channel behaves as described in the Fan Speed Control section. 1. This register becomes read-only when the Configuration Register 1 Lock bit is set to 1. Any subsequent attempts to write to this register fail. www.onsemi.com 58 ADT7473 Table 60. REGISTER 0X37 − DYNAMIC TMIN CONTROL REGISTER 2 (POWER-ON DEFAULT = 0X00) (Note 1) Bit No. Mnemonic R/W Description <2:0> CYR1 R/W 3-bit Remote 1 cycle value. These three bits define the delay time between making subsequent TMIN adjustments in the control loop for the Remote 1 channel, in terms of number of monitoring cycles. The system has associated thermal time constants that need to be found to optimize the response of fans and the control loop. Bits Decrease Cycle Increase Cycle 000 001 010 011 100 101 110 111 <5:3> CYL R/W CYR2 R/W 16 cycles (2 sec) 32 cycles (4 sec) 64 cycles (8 sec) 128 cycles (16 sec) 256 cycles (32 sec) 512 cycles (64 sec) 1024 cycles (128 sec) 2048 cycles (256 sec) 3-bit Local temperature cycle value. These three bits define the delay time between making subsequent TMIN adjustments in the control loop for the local temperature channel, in terms of number of monitoring cycles. The system has associated thermal time constants that need to be found to optimize the response of fans and the control loop. Bits Decrease Cycle Increase Cycle 000 001 010 011 100 101 110 111 <7:6> 8 cycles (1 sec) 16 cycles (2 sec) 32 cycles (4 sec) 64 cycles (8 sec) 128 cycles (16 sec) 256 cycles (32 sec) 512 cycles (64 sec) 1024 cycles (128 sec) 8 cycles (1 sec) 16 cycles (2 sec) 32 cycles (4 sec) 64 cycles (8 sec) 128 cycles (16 sec) 256 cycles (32 sec) 512 cycles (64 sec) 1024 cycles (128 sec) 16 cycles (2 sec) 32 cycles (4 sec) 64 cycles (8 sec) 128 cycles (16 sec) 256 cycles (32 sec) 512 cycles (64 sec) 1024 cycles (128 sec) 2048 cycles (256 sec) 2 LSBs of 3-bit Remote 2 cycle value. The MSB of the 3-bit code resides in Dynamic TMIN Control Register 1 (Register 0x36). These three bits define the delay time between making subsequent TMIN adjustments in the control loop for the Remote 2 channel, in terms of number of monitoring cycles. The system has associated thermal time constants that need to be found to optimize the response of fans and the control loop. Bits 000 001 010 011 100 101 110 111 Decrease Cycle 8 cycles (1 sec) 16 cycles (2 sec) 32 cycles (4 sec) 64 cycles (8 sec) 128 cycles (16 sec) 256 cycles (32 sec) 512 cycles (64 sec) 1024 cycles (128 sec) Increase Cycle 16 cycles (2 sec) 32 cycles (4 sec) 64 cycles (8 sec) 128 cycles (16 sec) 256 cycles (32 sec) 512 cycles (64 sec) 1024 cycles (128 sec) 2048 cycles (256 sec) 1. This register becomes read-only when the Configuration Register 1 Lock bit is set to 1. Any subsequent attempts to write to this register fail. Table 61. MAXIMUM PWM DUTY CYCLE REGISTERS (POWER-ON DEFAULT = 0XFF) (Note 1, 2, and 3) Description Register Address R/W (Note 2) 0x38 R/W Maximum Duty Cycle for PWM1 Output, Default = 100% (0xFF) 0x39 R/W Maximum Duty Cycle for PWM2 Output, Default = 100% (0xFF) 0x3A R/W Maximum Duty Cycle for PWM3 Output, Default = 100% (0xFF) 1. These registers set the maximum PWM duty cycle of the PWM output. 2. These registers become read-only when the Configuration Register 1 Lock bit is set to 1. Any subsequent attempts to write to this register fail. 3. If Bit 3 of Configuration Register 4 (0x7D) is set, then on a THERM overtemperature event, fans go to their maximum programmed PWM value as programmed here. If Bit 3 of Configuration Register 4 (0x7D) is 0, then on a THERM overtemperature event, fans go to 100% PWM. www.onsemi.com 59 ADT7473 Table 62. REGISTER 0X40 − CONFIGURATION REGISTER 1 (POWER-ON DEFAULT = 0X01) Bit No. Mnemonic R/W <0> STRT R/W Description <1> LOCK Write Once Logic 1 locks all limit values to their current settings. Once this bit is set, all lockable registers become read-only and cannot be modified until the ADT7473/ADT7473−1 is powered down and powered up again. This prevents rogue programs, such as viruses, from modifying critical system limit settings. (This is a lockable bit.) <2> RDY Read-only This bit is set to 1 by the ADT7473/ADT7473−1 to indicate only that the device is fully powered up and ready to begin system monitoring. <3> FSPD R/W When set to 1, this bit runs all fans at maximum speed as programmed in the maximum PWM duty cycle registers (0x30, 0x38, 0x39 and 0x3A ). Power-on default = 0. This bit is not locked at any time. <4> Vx1 R/W BIOS should set this bit to a 1 when the ADT7473/ADT7473−1 is configured to measure current from an ADI ADOPTt VRM controller and to measure the CPU’s core voltage. This bit allows monitoring software to display CPU watts usage. (This is a lockable bit.) <5> FSPDIS R/W Logic 1 disables fan spin-up for two TACH pulses. Instead, the PWM outputs go high for the entire fan spin-up timeout selected. <6> TODIS R/W When this bit is set to 1, the SMBus timeout feature is enabled. This allows the ADT7473/ADT7473−1 to be used with SMBus controllers that cannot handle SMBus timeouts. (This is a lockable bit.) <7> RES Latch Reset − Logic 1 enables monitoring and PWM control outputs based on the limit settings programmed. Logic 0 disables monitoring and PWM control based on the default powerup limit settings. This bit is not locked when Bit 1 (LOCK bit) has been written. This bit remains writable after lock bit is set. Reserved on the ADT7473. On the ADT7473−1, resets latch conditions when set to 1. Table 63. REGISTER 0X41 − INTERRUPT STATUS REGISTER 1 (POWER-ON DEFAULT = 0X00) Bit No. Mnemonic R/W Description <1> VCCP Read-only VCCP = 1 indicates the VCCP high or low limit has been exceeded. This bit is cleared on a read of the status register only if the error condition has subsided. <2> VCC Read-only VCC = 1 indicates the VCC high or low limit has been exceeded. This bit is cleared on a read of the status register only if the error condition has subsided. <4> R1T Read-only R1T = 1 indicates the Remote 1 low or high temperature has been exceeded. This bit is cleared on a read of the status register only if the error condition has subsided. <5> LT Read-only LT = 1 indicates the local low or high temperature has been exceeded. This bit is cleared on a read of the status register only if the error condition has subsided. <6> R2T Read-only R2T = 1 indicates the Remote 2 low or high temperature has been exceeded. This bit is cleared on a read of the status register only if the error condition has subsided. <7> OOL Read-only OOL = 1 indicates an out-of-limit event has been latched in Interrupt Status Register 2 (0x42). This bit is a logical OR of all status bits in Interrupt Status Register 2. Software can test this bit in isolation to determine whether any of the voltage, temperature, or fan speed readings represented by Interrupt Status Register 2 are out-of-limit, which saves the need to read Interrupt Status Register 2 every interrupt or polling cycle. www.onsemi.com 60 ADT7473 Table 64. REGISTER 0X42 − INTERRUPT STATUS REGISTER 2 (POWER-ON DEFAULT = 0X00) Bit No. Mnemonic R/W <0> RES THERM Limit Latch Read-only Reserved on the ADT7473 On the ADT7473−1, THERM Limit Latch = 1 indicates Remote Channel 2 latch. This is a THERM limit condition. <1> OVT Read-only OVT = 1 indicates one of the THERM overtemperature limits is exceeded. This bit is cleared on a read of the status register when the temperature drops below THERM – THYST. <2> FAN1 Read-only FAN1 = 1 indicates Fan 1 has dropped below minimum speed or has stalled. This bit is not set when the PWM1 output is off. <3> FAN2 Read-only FAN2 = 1 indicates Fan 2 has dropped below minimum speed or has stalled. This bit is not set when the PWM2 output is off. <4> FAN3 Read-only FAN3 = 1 indicates Fan 3 has dropped below minimum speed or has stalled. This bit is not set when the PWM3 output is off. <5> F4P Read-only F4P = 1 indicates Fan 4 has dropped below minimum speed or has stalled. This bit is not set when the PWM3 output is off. When Pin 9 is programmed as a GPIO output, writing to this bit determines the logic output of the GPIO. If Pin 9 is configured as the THERM timer input for THERM monitoring, then this bit is set when the THERM assertion time exceeds the limit programmed in the THERM timer limit register (Reg. 0x7A). R/W Read-only Description <6> D1 Read-only D1 = 1 indicates either an open or short circuit on the Thermal Diode 1 inputs. <7> D2 Read-only D2 = 1 indicates either an open or short circuit on the Thermal Diode 2 inputs. Table 65. VOLTAGE LIMIT REGISTERS (Note 1) Register Address R/W 0x46 R/W VCCP Low Limit Description (Note 2) Power-On Default 0x00 0x47 R/W VCCP High Limit 0xFF 0x48 R/W VCC Low Limit 0x00 0x49 R/W VCC High Limit 0xFF 1. Setting the Configuration Register 1 Lock bit has no effect on these registers. 2. High limits: an interrupt is generated when a value exceeds its high limit (> comparison). Low limits: an interrupt is generated when a value is equal to or below its low limit (≤ comparison). Table 66. TEMPERATURE LIMIT REGISTERS (Note 1) Register Address R/W 0x4E R/W Remote 1 Temperature Low Limit Description (Note 2) Power-On Default 0x01 0x4F R/W Remote 1 Temperature High Limit 0xFF 0x50 R/W Local Temperature Low Limit 0x01 0x51 R/W Local Temperature High Limit 0xFF 0x52 R/W Remote 2 Temperature Low Limit 0x01 0x53 R/W Remote 2 Temperature High Limit 0xFF 1. Exceeding any of these temperature limits by 1°C causes the appropriate status bit to be set in the interrupt status register. Setting the Configuration Register 1 Lock bit has no effect on these registers. 2. High limits: an interrupt is generated when a value exceeds its high limit (> comparison). Low limits: an interrupt is generated when a value is equal to or below its low limit (≤ comparison). www.onsemi.com 61 ADT7473 Table 67. FAN TACHOMETER LIMIT REGISTERS (Note 1) Register Address R/W 0x54 R/W TACH1 Minimum Low Byte Description Power-On Default 0xFF 0x55 R/W TACH1 Minimum High Byte/Single-channel ADC Channel Select 0xFF 0x56 R/W TACH2 Minimum Low Byte 0xFF 0x57 R/W TACH2 Minimum High Byte 0xFF 0x58 R/W TACH3 Minimum Low Byte 0xFF 0x59 R/W TACH3 Minimum High Byte 0xFF 0x5A R/W TACH4 Minimum Low Byte 0xFF 0x5B R/W TACH4 Minimum High Byte 0xFF 1. Exceeding any of the TACH limit registers by 1 indicates that the fan is running slowly or has stalled. The appropriate status bit is set in Interrupt Status Register 2 to indicate the fan failure. Setting the Configuration Register 1 Lock bit has no effect on these registers. Table 68. REGISTER 0X55 − TACH1 MINIMUM HIGH BYTE (POWER-ON DEFAULT = 0XFF) Bit No. Mnemonic R/W Description <4:0> Reserved Read-only These bits are reserved when Bit 6 of Configuration Register 2 (0x73) is set (single-channel ADC mode). Otherwise, these bits represent Bits <4:0> of the TACH1 minimum high byte. <7:5> SCADC R/W When Bit 6 of Configuration Register 2 (0x73) is set (single-channel ADC mode), these bits are used to select the only channel from which the ADC makes measurements. Otherwise, these bits represent Bits <7:5> of the TACH1 minimum high byte. Table 69. PWM CONFIGURATION REGISTERS Register Address R/W (Note 1) Description Power-On Default 0x5C R/W PWM1 Configuration ADT7473: 0x82 ADT7473−1: 0x62 0x5D R/W PWM2 Configuration ADT7473: 0x82 ADT7473−1: 0x62 0x5E R/W PWM3 Configuration ADT7473: 0x82 ADT7473−1: 0x62 1. These registers become read-only when the Configuration Register 1 Lock bit is set. Any further attempts to write to these registers have no effect. www.onsemi.com 62 ADT7473 Table 70. REGISTER 0X5C, REGISTER 0X5D, AND REGISTER 0X5E − CONFIGURATION REGISTERS (ADT7473 POWER-ON DEFAULT = 0X82, ADT7473−1 POWER-ON DEFAULT = 0X62) Bit No. Mnemonic R/W <2:0> SPIN R/W Description These bits control the startup timeout for PWMx. The PWM output stays high until two valid TACH rising edges are seen from the fan. If there is not a valid TACH signal during the fan TACH measurement directly after the fan startup timeout period, then the TACH measurement reads 0xFFFF and Interrupt Status Register 2 reflects the fan fault. If the TACH minimum high and low bytes contain 0xFFFF or 0x0000, then the Interrupt Status Register 2 bit is not set, even if the fan has not started. Bit Code Startup Time 000 001 010 011 100 101 110 111 No Startup Timeout 100 ms 250 ms (Default) 400 ms 667 ms 1 sec 2 sec 4 sec <3> SLOW R/W SLOW = 1 makes the ramp rates for acoustic enhancement four times longer. <4> INV R/W This bit inverts the PWM output. The default is 0, which corresponds to a logic high output for 100% duty cycle. Setting this bit to 1 inverts the PWM output, so 100% duty cycle corresponds to a logic low output. <7:5> BHVR R/W These bits assign each fan to a particular temperature sensor for localized cooling. 000 = Remote 1 temperature controls PWMx (automatic fan control mode). 001 = Local temperature controls PWMx (automatic fan control mode). 010 = Remote 2 temperature controls PWMx (automatic fan control mode). 011 = PWMx runs full speed (default for ADT7473−1). 100 = PWMx disabled (default for ADT7473). 101 = Fastest speed calculated by local and Remote 2 temperature controls PWMx. 110 = Fastest speed calculated by all three temperature channel controls PWMx. 111 = Manual mode. PWM duty cycle registers (Register 0x30 to Register 0x32) become writable. Table 71. TEMPERATURE TRANGE/PWM FREQUENCY REGISTERS Register Address R/W (Note 1) Description Power-On Default 0x5F R/W Remote 1 TRANGE/PWM1 Frequency 0xCC 0x60 R/W Local Temperature TRANGE/PWM2 Frequency 0xCC 0x61 R/W Remote 2 TRANGE/PWM3 Frequency 0xCC 1. These registers become read-only when the Configuration Register 1 Lock bit is set. Any further attempts to write to these registers have no effect. www.onsemi.com 63 ADT7473 Table 72. REGISTER 0X5F, REGISTER 0X60, AND REGISTER 0X61 − TEMP TRANGE/PWM FREQUENCY REGISTERS, (POWER-ON DEFAULT = 0XCC) Bit No. Mnemonic R/W <2:0> FREQ R/W Description These bits control the PWMx frequency. Bit Code Frequency 000 001 010 011 100 101 110 111 11.0 Hz 14.7 Hz 22.1 Hz 29.4 Hz 35.3 Hz (Default) 44.1 Hz 58.8 Hz 88.2 Hz <3> HF/LF R/W HF/LF = 1, high frequency PWM output for 4-wire fans. Once enabled, 3-wire fan-specific settings have no effect. 0x5F, HF/LF = 1, Enables High Frequency Mode for Fan 1 0x60, HF/LF = 1, Enables High Frequency Mode for Fan 2 0x61, HF/LF = 1, Enables High Frequency Mode for Fan 3 <7:4> RANGE R/W These bits determine the PWM duty cycle vs. the temperature slope for automatic fan control. Bit Code Temperature 0000 0001 0010 0011 0100 0101 0110 0111 1000 1001 1010 1011 1100 1101 1110 1111 2°C 2.5°C 3.33°C 4°C 5°C 6.67°C 8°C 10°C 13.33°C 16°C 20°C 26.67°C 32°C (Default) 40°C 53.33°C 80°C www.onsemi.com 64 ADT7473 Table 73. REGISTER 0X62 − ENHANCED ACOUSTICS REGISTER 1 (POWER-ON DEFAULT = 0X00) Bit No. Mnemonic R/W (Note 1) Description <2:0> ACOU R/W These bits select the ramp rate applied to the PWM1 output. Instead of PWM1 jumping instantaneously to its newly calculated speed, PWM1 ramps gradually at the rate determined by these bits. This feature enhances the acoustics of the fan being driven by the PWM1 output. Time Slot Increase Time for 33% to 100% 000 = 1 001 = 2 010 = 3 011 = 4 100 = 8 101 = 12 110 = 24 111 = 48 35 sec 17.6 sec 11.8 sec 7.0 sec 4.4 sec 3.0 sec 1.6 sec 0.8 sec <3> EN1 R/W When this bit is 1, acoustic enhancement is enabled on PWM1 output. <4> SYNC R/W SYNC = 1 synchronizes fan speed measurements on TACH2, TACH3, and TACH4 to PWM3. This allows up to three fans to be driven from PWM3 output and their speeds to be measured. SYNC = 0 synchronizes only TACH3 and TACH4 to PWM3 output. <5> MIN1 R/W When the ADT7473/ADT7473−1 is in automatic fan control mode, this bit defines whether PWM1 is off (0% duty cycle) or at PWM1 minimum duty cycle when the controlling temperature is below its TMIN – hysteresis value. 0 = 0% duty cycle below TMIN − hysteresis. 1 = PWM1 minimum duty cycle below TMIN − hysteresis. <6> MIN2 R/W When the ADT7473/ADT7473−1 is in automatic fan speed control mode, this bit defines whether PWM2 is off (0% duty cycle) or at PWM2 minimum duty cycle when the controlling temperature is below its TMIN − hysteresis value. 0 = 0% duty cycle below TMIN − hysteresis. 1 = PWM 2 minimum duty cycle below TMIN − hysteresis. <7> MIN3 R/W When the ADT7473/ADT7473−1 is in automatic fan speed control mode, this bit defines whether PWM3 is off (0% duty cycle) or at PWM3 minimum duty cycle when the controlling temperature is below its TMIN − hysteresis value. 0 = 0% duty cycle below TMIN − hysteresis. 1 = PWM3 minimum duty cycle below TMIN − hysteresis. 1. This register becomes read-only when the Configuration Register 1 Lock bit is set to 1. Any further attempts to write to this register have no effect. www.onsemi.com 65 ADT7473 Table 74. Register 0x63 − Enhanced Acoustics Register 2 (Power-On Default = 0x00) Bit No. Mnemonic R/W (Note 1) <2:0> ACOU3 R/W Description These bits select the ramp rate applied to the PWM3 output. Instead of PWM3 jumping instantly to its newly calculated speed, PWM3 ramps gradually at the rate determined by these bits. This effect enhances the acoustics of the fan being driven by the PWM3 output. Time Slot Increase Time for 33% to 100% 000 = 1 001 = 2 010 = 3 011 = 4 100 = 8 101 = 12 110 = 24 111 = 48 35 sec 17.6 sec 11.8 sec 7.0 sec 4.4 sec 3.0 sec 1.6 sec 0.8 sec <3> EN3 R/W When this bit is 1, acoustic enhancement is enabled on PWM3 output. <6:4> ACOU2 R/W These bits select the ramp rate applied to the PWM2 output. Instead of PWM2 jumping instantly to its newly calculated speed, PWM2 ramps gradually at the rate determined by these bits. This effect enhances the acoustics of the fans being driven by the PWM2 output. Time Slot Increase Time for 33% to 100% 000 = 1 001 = 2 010 = 3 011 = 4 100 = 8 101 = 12 110 = 24 111 = 48 <7> EN2 R/W 35 sec 17.6 sec 11.8 sec 7.0 sec 4.4 sec 3.0 sec 1.6 sec 0.8 sec When this bit is 1, acoustic enhancement is enabled on PWM2 output. 1. This register becomes read-only when the Configuration Register 1 Lock bit is set to 1. Any further attempts to write to this register have no effect. Table 75. PWM MINIMUM DUTY CYCLE REGISTERS Register Address R/W (Note 1) Description Power-On Default 0x64 R/W PWM1 Minimum Duty Cycle 0x80 (50% Duty Cycle) 0x65 R/W PWM2 Minimum Duty Cycle 0x80 (50% Duty Cycle) 0x66 R/W PWM3 Minimum Duty Cycle 0x80 (50% Duty Cycle) 1. These registers become read-only when the Configuration Register 1 Lock bit is set. Any further attempts to write to these registers have no effect. Table 76. REGISTER 0X64, REGISTER 0X65, AND REGISTER 0X66 - PWM MINIMUM DUTY CYCLE REGISTERS (POWER-ON DEFAULT = 0X80, 50% DUTY CYCLE) Bit No. Mnemonic R/W Description <7:0> PWM Duty Cycle R/W These bits define the PWMMIN duty cycle for PWMx. 0x00 = 0% Duty Cycle (Fan Off) 0x40 = 25% Duty Cycle 0x80 = 50% Duty Cycle 0xFF = 100% Duty Cycle (Fan Full Speed) Table 77. TMIN REGISTERS (Note 1) Register Address R/W (Note 2) 0x67 R/W Remote 1 Temperature TMIN Description Power-On Default 0x9A (90°C) 0x68 R/W Local Temperature TMIN 0x9A (90°C) 0x69 R/W Remote 2 Temperature TMIN 0x9A (90°C) 1. These are the TMIN registers for each temperature channel. When the temperature measured exceeds TMIN, the appropriate fan runs at minimum speed and increases with temperature according to TRANGE. 2. These registers become read-only when the Configuration Register 1 Lock bit is set. Any further attempts to write to these registers have no effect. www.onsemi.com 66 ADT7473 Table 78. THERM LIMIT REGISTERS (Note 1) Register Address R/W (Note 2) 0x6A R/W Remote 1 THERM Limit Description Power-On Default 0xA4 (100°C) 0x6B R/W Local THERM Limit 0xA4 (100°C) 0x6C R/W Remote 2 THERM Limit ADT7473: 0xA4 (100°C) ADT7473−1: 0xC8 (136°C) 1. If any temperature measured exceeds its THERM limit, all PWM outputs drive their fans at 100% duty cycle. This is a fail-safe mechanism incorporated to cool the system in the event of a critical overtemperature. It also ensures some level of cooling in the event that software or hardware locks up. If set to 0x80, this feature is disabled. The PWM output remains at 100% until the temperature drops below THERM Limit − Hysteresis. If the THERM pin is programmed as an output, then exceeding these limits by 0.25°C can cause the THERM pin to assert low as an output. 2. These registers become read-only when the Configuration Register 1 Lock bit is set to 1. Any further attempts to write to these registers have no effect. Table 79. TEMPERATURE/TMIN HYSTERESIS REGISTERS (Note 1) Register Address Bit Name 0x6D R/W (Note 2) R/W Description Remote 1 and local temperature hysteresis. HYSL <3:0> Local temperature hysteresis. 0°C to 15°C of hysteresis can be applied to the local temperature AFC and dynamic TMIN control loops. HYSR1 <7:4> Remote 1 temperature hysteresis. 0°C to 15°C of hysteresis can be applied to the Remote 1 temperature AFC and dynamic TMIN control loops. 0x6E R/W HYSR2 <7:4> Remote 2 temperature hysteresis. Power-On Default 0x44 0x40 Local temperature hysteresis. 0°C to 15°C of hysteresis can be applied to the local temperature AFC and dynamic TMIN control loops. 1. Each 4 bit value controls the amount of temperature hysteresis applied to a particular temperature channel. Once the temperature for that channel falls below its TMIN value, the fan remains running at PWMMIN duty cycle until the temperature = TMIN – hysteresis. Up to 15°C of hysteresis can be assigned to any temperature channel. The hysteresis value chosen also applies to that temperature channel, if its THERM limit is exceeded. The PWM output being controlled goes to 100%, if the THERM limit is exceeded and remains at 100% until the temperature drops below THERM – hysteresis. For acoustic reasons, it is recommended that the hysteresis value not be programmed less than 4°C. Setting the hysteresis value lower than 4°C causes the fan to switch on and off regularly when the temperature is close to TMIN. 2. These registers become read-only when the Configuration Register 1 Lock bit is set to 1. Any further attempts to write to these registers have no effect. Table 80. XNOR TREE TEST REGISTER Register Address Bit Name 0x6F R/W (Note 1) R/W Description XNOR tree test enable register. XEN <0> If the XEN bit is set to 1, the device enters the XNOR tree test mode. Clearing the bit removes the device from the XNOR tree test mode. Res <7:1> Unused. Do not write to these bits. Power-On Default 0x00 1. These registers become read-only when the Configuration Register 1 Lock bit is set to 1. Any further attempts to write to these registers have no effect. Table 81. REMOTE 1 TEMPERATURE OFFSET REGISTER (0X70) Register Address R/W (Note 1) <7:0> R/W Description Allows a twos complement offset value to be automatically added to or subtracted from the Remote 1 temperature reading. This is to compensate for any inherent system offsets such as PCB trace resistance. LSB value = 0.5°C. Power-On Default 0x00 1. This register becomes read-only when the Configuration Register 1 Lock bit is set to 1. Any further attempts to write to this register have no effect. www.onsemi.com 67 ADT7473 Table 82. LOCAL TEMPERATURE OFFSET REGISTER (0X71) Register Address R/W (Note 1) Description Power-On Default <7:0> R/W Allows a twos complement offset value to be automatically added to or subtracted from the local temperature reading. LSB value = 0.5°C. 0x00 1. This register becomes read-only when the Configuration Register 1 Lock bit is set to 1. Any further attempts to write to this register have no effect. Table 83. REMOTE 2 TEMPERATURE OFFSET REGISTER (0X72) Register Address R/W (Note 1) <7:0> R/W Description Power-On Default Allows a twos complement offset value to be automatically added to or subtracted from the Remote 2 temperature reading. This is to compensate for any inherent system offsets such as PCB trace resistance. LSB value = 0.5°C. 0x00 1. This register becomes read-only when the Configuration Register 1 Lock bit is set to 1. Any further attempts to write to this register have no effect. Table 84. REGISTER 0X73 − CONFIGURATION REGISTER 2 (POWER-ON DEFAULT = 0X00) Bit No. Mnemonic R/W (Note 1) Description <0> FanPresDT R/W When FanPresenceDT = 1, the state of Bits <3:1> of Register 0x73 reflects the presence of a 4-wire fan on the appropriate TACH channel. <1> Fan1Detect Read-only Fan1 Detect = 1 indicates a 4-wire fan is connected to the PWM1 input. <2> Fan2Detect Read-only Fan1 Detect = 1 indicates a 4-wire fan is connected to the PWM2 input. <3> Fan3Detect Read-only Fan1 Detect = 1 indicates a 4-wire fan is connected to the PWM3 input. <4> AVG R/W AVG = 1, averaging on the temperature and voltage measurements is turned off. This allows measurements on each channel to be made much faster. <5> ATTN R/W ATTN = 1, the ADT7473/ADT7473−1 removes the attenuators from the VCCP input. The VCCP input can be used for other functions such as connecting up external sensors. <6> CONV R/W CONV = 1, the ADT7473/ADT7473−1 is put into a single-channel ADC conversion mode. In this mode, the ADT7473/ADT7473−1 can be made to read continuously from one input only, for example, Remote 1 temperature. The appropriate ADC channel is selected by writing to Bits <7:5> of TACH1 minimum high byte register (0x55). Bits <7:5>, Register 0x55 000 001 010 011 100 101 110 111 <7> Shutdown R/W Reserved VCCP VCC (3.3 V) Reserved Reserved Remote 1 Temperature Local Temperature Remote 2 Temperature SHDN = 1, ADT7473/ADT7473−1 goes into shutdown mode. All PWM outputs assert low or high, depending on the state of the INV bit, to switch off all fans. 1. This register becomes read-only when the Configuration Register 1Lock bit is set to 1. Any further attempts to write to this register have no effect. Table 85. REGISTER 0X74 − INTERRUPT MASK REGISTER 1 (POWER-ON DEFAULT = 0X00) Bit No. Mnemonic R/W <1> VCCP R/W VCCP = 1, masks SMBALERT for out-of-limit conditions on the VCCP channel. Description <2> VCC R/W VCC = 1, masks SMBALERT for out-of-limit conditions on the VCC channel. <4> R1T R/W R1T = 1, masks SMBALERT for out-of-limit conditions on the Remote 1 temperature channel. <5> LT R/W LT = 1, masks SMBALERT for out-of-limit conditions on the local temperature channel. <6> R2T R/W R2T = 1, masks SMBALERT for out-of-limit conditions on the Remote 2 temperature channel. <7> OOL R/W OOL = 0, then when one or more alerts are generated in Interrupt Status Register 2, assuming all the mask bits in the Interrupt Mask Register 2 (0x75) = 1, SMBALERT are still asserted. OOL = 1, then when one or more alerts are generated in Interrupt Status Register 2, assuming all the mask bits in the Interrupt Mask Register 2 (0x75) = 1, SMBALERT are not asserted. www.onsemi.com 68 ADT7473 Table 86. REGISTER 0X75 − INTERRUPT MASK REGISTER 2 (POWER-ON DEFAULT <7:0> = 0X00) Bit No. Mnemonic R/W <1> OVT R/W OVT = 1, masks SMBALERT for overtemperature THERM conditions. Description <2> FAN1 R/W FAN1 = 1, masks SMBALERT for a Fan 1 fault. <3> FAN2 R/W FAN2 = 1, masks SMBALERT for a Fan 2 fault. <4> FAN3 R/W FAN3 = 1, masks SMBALERT for a Fan 3 fault. <5> F4P R/W F4P = 1, masks SMBALERT for a Fan 4 fault. If the TACH4 pin is being used as the THERM input, this bit masks SMBALERT for a THERM timer event. <6> D1 R/W D1 = 1, masks SMBALERT for a diode open or short on a Remote 1 channel. <7> D2 R/W D2 = 1, masks SMBALERT for a diode open or short on a Remote 2 channel. Table 87. REGISTER 0X76 − EXTENDED RESOLUTION REGISTER 1 (POWER-ON DEFAULT = 0X00) (Note 1) Bit No. Mnemonic R/W <3:2> VCCP Read-only VCCP LSBs. Holds the 2 LSBs of the 10-bit VCCP measurement. Description <5:4> VCC Read-only VCC LSBs. Holds the 2 LSBs of the 10-bit VCC measurement. 1. If this register is read, this register and the registers holding the MSB of each reading are frozen until read. Table 88. REGISTER 0X77 − EXTENDED RESOLUTION REGISTER 2 (POWER-ON DEFAULT = 0X00) (Note 1) Bit No. Mnemonic R/W <3:2> TDM1 Read-only Remote 1 temperature LSBs. Holds the 2 LSBs of the 10-bit Remote 1 temperature measurement. Description <5:4> LTMP Read-only Local temperature LSBs. Holds the 2 LSBs of the 10-bit local temperature measurement. <7:6> TDM2 Read-only Remote 2 temperature LSBs. Holds the 2 LSBs of the 10-bit Remote 2 temperature measurement. 1. If this register is read, this register and the registers holding the MSB of each reading are frozen until read. Table 89. REGISTER 0X78 − CONFIGURATION REGISTER 3 (POWER-ON DEFAULT = 0X00) Bit No. Mnemonic R/W (Note 1) <0> ALERT Enable R/W ALERT = 0 (default), ADT7473 Pin 5 is configured as PWM2. ALERT = 1, Pin 5 for ADT7473 (PWM2/SMBALERT) is configured as an SMBALERT interrupt output to indicate out-of-limit error conditions. ALERT = 0 (default), ADT7473−1 Pin 5 is configured as. THERM_LATCH. ALERT = 1, Pin 5 for ADT7473−1 (THERM_LATCH/PWM2) is configured as PWM2. Description <1> THERM R/W THERM Enable = 1 enables THERM functionality on Pin 9. Also determined by Bit 0 and Bit 1 (PIN9FUNC) of Configuration Register 4. Direction is controlled by Bit 5, Bit 6, and Bit 7 of Configuration Register 5 (0x7C). When THERM is asserted, if the fans are running and the boost bit is set, the fans run at full speed. THERM can also be programmed so that a timer monitors the duration THERM has been asserted. <2> BOOST R/W When THERM is an input and BOOST = 1, assertion of THERM causes all fans to run at the maximum programmed duty cycle for fail-safe cooling. <3> FAST R/W FAST = 1, enables fast TACH measurements on all channels. This increases the TACH measurement rate from once per second to once every 250 ms (4x). <4> DC1 R/W DC1 = 1, enables TACH measurements to be continuously made on TACH1. Fans must be driven by dc. Setting this bit prevents pulse stretching because it is not required for dc-driven motors. <5> DC2 R/W DC2 = 1, enables TACH measurements to be continuously made on TACH2. Fans must be driven by dc. Setting this bit prevents pulse stretching because it is not required for dc-driven motors. <6> DC3 R/W DC3 = 1, enables TACH measurements to be continuously made on TACH3. Fans must be driven by dc. Setting this bit prevents pulse stretching because it is not required for dc-driven motors. <7> DC4 R/W DC4 = 1, enables TACH measurements to be continuously made on TACH4. Fans must be driven by dc. Setting this bit prevents pulse stretching because it is not required for dc-driven motors. www.onsemi.com 69 ADT7473 1. This register becomes read-only when the Configuration Register 1 Lock bit is set to 1. Any further attempts to write to this register have no effect. Table 90. REGISTER 0X79 − THERM TIMER STATUS REGISTER (POWER-ON DEFAULT = 0X00) Bit No. Mnemonic R/W Description <7:1> TMR R Times how long THERM input is asserted. These seven bits read 0 until the THERM assertion time exceeds 45.52 ms. <0> ASRT/ TMR0 R This bit is set high on the assertion of the THERM input and is cleared on read. If the THERM assertion time exceeds 45.52 ms, this bit is set and becomes the LSB of the 8-bit TMR reading. This allows THERM assertion times from 45.52 ms to 5.82 sec to be reported back with a resolution of 22.76 ms. Table 91. REGISTER 0X7A − THERM TIMER LIMIT REGISTER (POWER-ON DEFAULT = 0X00) Bit No. Mnemonic R/W Description <7:0> LIMT R/W Sets maximum THERM assertion length allowed before an interrupt is generated. This is an 8-bit limit with a resolution of 22.76 ms allowing THERM assertion limits of 45.52 ms to 5.82 seconds to be programmed. If the THERM assertion time exceeds this limit, Bit 5 (F4P) of Interrupt Status Register 2 (Reg. 0x42) is set. If the limit value is 0x00, an interrupt is generated immediately on the assertion of the THERM input. Table 92. REGISTER 0X7B − TACH PULSES PER REVOLUTION REGISTER (POWER-ON DEFAULT = 0X55) Bit No. Mnemonic R/W <1:0> FAN1 R/W Description Sets number of pulses to be counted when measuring Fan 1 speed. Can be used to determine fan pulses per revolution for unknown fan type. Bit Code Pulses Counted 00 01 10 11 <3:2> FAN2 R/W Sets number of pulses to be counted when measuring Fan 2 speed. Can be used to determine fan pulses per revolution for unknown fan type. Bit Code Pulses Counted 00 01 10 11 <5:4> FAN3 R/W FAN4 R/W 1 2 (Default) 3 4 Sets number of pulses to be counted when measuring Fan 3 speed. Can be used to determine fan pulses per revolution for unknown fan type. Bit Code Pulses Counted 00 01 10 11 <7:6> 1 2 (Default) 3 4 1 2 (Default) 3 4 Sets number of pulses to be counted when measuring Fan 4 speed. Can be used to determine fan pulses per revolution for unknown fan type. Bit Code Pulses Counted 00 01 10 11 1 2 (Default) 3 4 www.onsemi.com 70 ADT7473 Table 93. REGISTER 0X7C − CONFIGURATION REGISTER 5 (ADT7473POWER-ON DEFAULT = 0X00) Bit No. Mnemonic R/W (Note 1) <0> TWOS COMPL R/W Description <1> Temp Offset − TempOffset = 0 sets offset range to ±64°C at 0.5°C resolution. TempOffset = 1 sets offset range to ±128°C at 1°C resolution. <2> GPIOD − GPIO direction. When GPIO function is enabled, this determines whether the GPIO is an input (0) or an output (1). <3> GPIOP − GPIO polarity. When the GPIO function is enabled and is programmed as an output, this bit determines whether the GPIO is active low (0) or high (1). <4> RES THERM Hysteresis R/W Reserved on the ADT7473 On the ADT7473−1: 0 = THERM hysteresis disabled 1 = THERM hysteresis enabled <5> R1 THERM R/W R1 THERM = 1, THERM temperature limit functionality enabled for Remote 1 temperature channel; that is, THERM is bidirectional. R1 THERM = 0, THERM is a timer input only. THERM can also be disabled on any channel by: Writing −64°C to the appropriate THERM temperature limit in Offset 64 mode. Writing −128°C to the appropriate THERM temperature limit in twos complement mode. <6> Local THERM R/W Local THERM = 1, THERM temperature limit functionality enabled for the local temperature channel; that is, THERM is bidirectional. Local THERM = 0, THERM is a timer input only. THERM can also be disabled on any channel by: Writing −64°C to the appropriate THERM temperature limit in Offset 64 mode. Writing −128°C to the appropriate THERM temperature limit in twos complement mode. <7> R2 THERM R/W R2 THERM = 1, THERM temperature limit functionality enabled for Remote 2 temperature channel; that is, THERM is bidirectional. R2 THERM = 0, THERM is a timer input only. THERM can also be disabled on any channel by: Writing −64°C to the appropriate THERM temperature limit in Offset 64 mode. Writing −128°C to the appropriate THERM temperature limit in twos complement mode. Twos complement = 1, sets the temperature range to twos complement temperature range. Twos complement = 0, changes the temperature range to Offset 64. When this bit is changed, the ADT7473/ADT7473−1 interprets all relevant temperature register values as defined by this bit. 1. This register becomes read-only when the Configuration Register 1 Lock bit is set to 1. Any further attempts to write to this register have no effect. Table 94. REGISTER 0X7D − CONFIGURATION REGISTER 4 (POWER-ON DEFAULT = 0X00) Bit No. Mnemonic R/W (Note 1) <1:0> Pin9FUNC R/W These bits set the functionality of Pin 9. 00 = TACH4 (Default) 01 = THERM 11 = SMBALERT 10 = GPIO Description <2> THERM Disable R/W THERM Disable = 1, disables THERM overtemperature output features. <3> Max/Full on THERM R/W Max/Full on THERM = 0; when THERM temperature limit is exceeded, fans go to full speed. Max/Full on THERM = 1; when THERM temperature limit is exceeded, fans go to maximum programmed fan speed. Max/Full on THERM = 1; when THERM limit is exceeded, fans go to maximum speed as defined in Register 0x38, Register 0x39, Register 0x3A. <4> RES THERM Config <5> BpAttVCCP <6> RES Reserved <7> RES Reserved Unused on ADT7473. On the ADT7473−1: 0 = Remote Channel 2 (Default) 1 = Remote Channel 1 and Remote Channel 2 R/W Bypass VCCP attenuator. When set, the measurement scale for this channel changes from 0 V (0x00) to 2.2965 V (0xFF). 1. This register becomes read-only when the Configuration Register 1 Lock bit is set to 1. Any further attempts to write to this register have no effect. www.onsemi.com 71 ADT7473 Table 95. REGISTER 0X7E − MANUFACTURER’S TEST REGISTER 1 (POWER-ON DEFAULT = 0X00) Bit No. Mnemonic R/W <7:0> Reserved Read-only Description Manufacturer’s test register. These bits are reserved for manufacturer’s test purposes and should not be written to under normal operation. Table 96. REGISTER 0X7F − MANUFACTURER’S TEST REGISTER 2 (POWER-ON DEFAULT = 0X00) Bit No. Mnemonic R/W <7:0> Reserved Read-only Description Manufacturer’s test register. These bits are reserved for manufacturer’s test purposes and should not be written to under normal operation. Table 97. REGISTER 0X80 − MANUFACTURER’S TEST REGISTER 3 (POWER-ON DEFAULT = 0X10) Bit No. Mnemonic R/W <7:0> Reserved Read-only Description Manufacturer’s test register. These bits are reserved for manufacturer’s test purposes and should not be written to under normal operation. Table 98. ORDERING INFORMATION Package Type Package Option Shipping† ADT7473ARQZ−REEL 16-lead QSOP RQ−16 2,500 Tape & Reel ADT7473ARQZ−1RL 16-lead QSOP RQ−16 2,500 Tape & Reel Device Order Number* †For information on tape and reel specifications, including part orientation and tape sizes, please refer to our Tape and Reel Packaging Specifications Brochure, BRD8011/D. *These are Pb-Free packages. www.onsemi.com 72 ADT7473 PACKAGE DIMENSIONS QSOP16 CASE 492 ISSUE A 2X NOTES: 1. DIMENSIONING AND TOLERANCING PER ASME Y14.5M, 1994. 2. CONTROLLING DIMENSION: MILLIMETERS. 3. DIMENSION b DOES NOT INCLUDE DAMBAR PROTRUSION. 4. DIMENSION D DOES NOT INCLUDE MOLD FLASH, PROTRUSIONS, OR GATE BURRS. MOLD FLASH, PROTRUSIONS, OR GATE BURRS SHALL NOT EX CEED 0.005 PER SIDE. DIMENSION E1 DOES NOT INCLUDE INTERLEAD FLASH OR PROTRUSION. IN TERLEAD FLASH OR PROTRUSION SHALL NOT EX CEED 0.005 PER SIDE. D AND E1 ARE DETERMINED AT DATUM H. 5. DATUMS A AND B ARE DETERMINED AT DATUM H. 0.20 C D D 16 L2 D A 9 GAUGE PLANE SEATING PLANE E E1 C C L 2X DETAIL A 0.20 C D 2X 10 TIPS 1 8 0.25 C D 16X e B b 0.25 M C A-B D h x 45 _ A2 0.10 C 0.10 C 16X H A A1 C SEATING PLANE DETAIL A M DIM A A1 A2 b c D E E1 e h L L2 M INCHES MIN MAX 0.053 0.069 0.004 0.010 0.049 ---0.008 0.012 0.007 0.010 0.193 BSC 0.237 BSC 0.154 BSC 0.025 BSC 0.009 0.020 0.016 0.050 0.010 BSC 0_ 8_ MILLIMETERS MIN MAX 1.35 1.75 0.10 0.25 1.24 ---0.20 0.30 0.19 0.25 4.89 BSC 6.00 BSC 3.90 BSC 0.635 BSC 0.22 0.50 0.40 1.27 0.25 BSC 0_ 8_ SOLDERING FOOTPRINT 16X 16X 0.42 16 1.12 9 6.40 1 8 0.635 PITCH DIMENSIONS: MILLIMETERS *For additional information on our Pb-Free strategy and soldering details, please download the ON Semiconductor Soldering and Mounting Techniques Reference Manual, SOLDERRM/D. Pentium is a registered trademark of Intel Corporation. ON Semiconductor and the are registered trademarks of Semiconductor Components Industries, LLC (SCILLC) or its subsidiaries in the United States and/or other countries. SCILLC owns the rights to a number of patents, trademarks, copyrights, trade secrets, and other intellectual property. A listing of SCILLC’s product/patent coverage may be accessed at www.onsemi.com/site/pdf/Patent−Marking.pdf. SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does SCILLC assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential or incidental damages. “Typical” parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. SCILLC does not convey any license under its patent rights nor the rights of others. SCILLC products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or other applications intended to support or sustain life, or for any other application in which the failure of the SCILLC product could create a situation where personal injury or death may occur. Should Buyer purchase or use SCILLC products for any such unintended or unauthorized application, Buyer shall indemnify and hold SCILLC and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that SCILLC was negligent regarding the design or manufacture of the part. SCILLC is an Equal Opportunity/Affirmative Action Employer. This literature is subject to all applicable copyright laws and is not for resale in any manner. PUBLICATION ORDERING INFORMATION LITERATURE FULFILLMENT: Literature Distribution Center for ON Semiconductor P.O. Box 5163, Denver, Colorado 80217 USA Phone: 303−675−2175 or 800−344−3860 Toll Free USA/Canada Fax: 303−675−2176 or 800−344−3867 Toll Free USA/Canada Email: [email protected] N. American Technical Support: 800−282−9855 Toll Free USA/Canada Europe, Middle East and Africa Technical Support: Phone: 421 33 790 2910 Japan Customer Focus Center Phone: 81−3−5817−1050 www.onsemi.com 73 ON Semiconductor Website: www.onsemi.com Order Literature: http://www.onsemi.com/orderlit For additional information, please contact your local Sales Representative ADT7473/D