Energy-saving fans with ESM, ACi and iQ/iQ2-motor The engineer’s choice version 2012-10 The new generation of energy-saving fans Energy savings have become an important topic in almost every aspect of life. Our extended energy saving fan series, based on the energy saving motor (ESM) and the iQ-motor, offers high efficiency throughout a long service life and a significant decrease in energy consumption along with it. This is precisely what is required for refrigeration systems, such as in refrigerated and freezer cases or for condensing units. Comprehensive series The series of these energy saving fans includes the compact fan series of ACi 4400 as well as based on the energy saving motor (ESM), axial fans and centrifugal modules as well as the iQ-motor as an energy saving variant of the Q-motor. Axial fans are available in sizes of 130, 172, 200, 230, 250 and 300 mm plus the compact fan ACi 4400 with the dimensions 119 x 119 x 38 mm. With their new rotors and wall rings, which have been optimised according to aerodynamic criteria, the fans now work even more quietly and require no varnish, a particularly environmentally friendly feature. Energy saving centrifugal modules are available in sizes of 190 and 220 mm. These are especially appealing due to their compact and aerodynamically optimised design, which allows customers to install them quickly and hassle-free. The K1G200 energy saving centrifugal module in a diagonal impeller design rounds out the ESM series. It particularly distinguishes itself due to noise-optimised and air flow-optimised performance in the medium pressure range. ebm-papst sets the benchmark here, too. The existing series was expanded with additional versions and functions to meet new market demands. Among other things, this includes a 24 VDC design with an integrated 0-10 VDC open loop speed control and a speed monitoring output. A 0-10 VDC open loop speed control is now possible even for the existing line-fed designs by using an ESM+ plug-in module. This series is supplemented by the energy saving iQ-motor based on ebm-papst's GreenTech EC technology. The iQ2 series further expands the offering with additional functions. Due to its dimensions and mounting options, which are identical to the Q-motor already established on the market, customers are given the possibility of a 1:1 replacement without extensive renovations. The iQ-motor can be readily installed with normal axial impellers with a 154 to 254 mm diameter. Maximum efficiency Our fans and motors achieve a maximum motor efficiency of over 70% and thus only need 1/3 to 1/6 of the power of an otherwise normal shaded-pole motor. Higher efficiency also means lower intrinsic heating during operation at the same time, which dissipates less heat into the surrounding area. This means that less cooling power must be generated, thus resulting in additional energy savings. 2 Table of contents The new generation of energy-saving fans 2 Green Tech: The Green Company 4 Energy-saving axial fans 6 Energy-saving centrifugal modules 32 ESM/ACi accessories 40 ESM electrical connections 46 iQ/iQ2-motor 48 iQ/iQ2-motor accessories 58 Technical parameters & scope 62 ebm-papst representatives & subsidiaries 66 3 Sustainability is at the centre of our thoughts and actions. Out of conviction! Eco-friendliness and sustainability have always been at the core of our thoughts and actions. For decades, we have worked according to the simple but strict creed of our co-founder Gerhard Sturm: “Each new product we develop has to be better than the last one in terms of economy and ecology.” GreenTech is the ultimate expression of our corporate philosophy. GreenTech is pro-active development. GreenTech is acknowledged and certified. Even in the design phase, the materials and processes we use are optimi- Every step in our chain of production meets the stringent standards of sed for the greatest possible eco-friendliness, energy balance and – environmental specialists and the public. The 2008 Environmental Prize wherever possible – recyclability. We continually improve the material of Baden-Wuerttemberg, the Green Award 2009, the Energy Efficiency and performance of our products, as well as the flow and noise charac- Award 2009 of the dena – to give just a few examples – testify to this. teristics. At the same time, we significantly reduce energy consumption. The environmental advantage gained in the performance of the products Close co-operation with universities and scientific institutes and the pro- developed from our GreenTech philosophy can also be measured in the fessorship we endow in the area of power engineering and regenerative fulfilment of the most stringent energy and environmental standards. energies allows us to profit from the latest research findings in these In many instances, our products are already well below the thresholds fields – and at the same time ensure highly qualified young academics. energy legislation will impose a few years from now – several times over. GreenTech is eco-friendly production. Our customers profit from this every day. GreenTech also stands for maximum energy efficiency in our production The heart of GreenTech is future-oriented EC technology from ebm- processes. There, the intelligent use of industrial waste heat and ground- papst. The EC technology at the core of our most efficient motors and water cooling, photovoltaics and, of course, our own cooling and venti - fans allows efficiency of up to 90%, saves energy at a very high level, lation technology are of the utmost importance. Our most modern plant, significantly extends service life and makes our products maintenance- for instance, consumes 91% less energy than currently specified and free. These values pay off not only for the environment, but every cent al- required. In this way, our products contribute to protecting the environ- so pays off for the user! All ebm-papst products – even those for which ment, from their origin to their recyclable packaging. GreenTech EC technology does not (yet) make sense from an application viewpoint – feature the greatest possible connection of economy and ecology. 5 Series: The existing series of energy saving axial fans was expanded by adding the ACi 4400 series and a compact fan with size 130. In addition, the ESM series is now available as a 24 VDC version with an integrated 0-10 VDC open loop speed control output and a speed monitoring signal. These control options have also become possible for line-fed designs via an additional ESM+ plug-in module. System: Not just our existing shaded-pole motors were replaced by high-efficiency GreenTech EC motors for our fans, but a complete new system was developed as a whole consisting of an EC motor, impeller and wall ring. Optimum efficiency for the best possible noise behaviour was only able to be achieved by having all of the components perfectly harmonised together. Energy efficiency: The energy saving motors achieve a maximum efficiency of over 70%. So they only need 1/3 to 1/6 the power of an otherwise normal shaded-pole motor. But higher efficiency also means lower intrinsic heating during operation at the same time, which dissipates less heat into the surrounding area. This results in further energy savings, since less cooling capacity needs to be put in place from the beginning. Easy installation: Effort needed by the customer for installation and logistics is reduced to a minimum due to the complete system. In addition to the fan itself, only screws are needed for mounting. Further savings result from the pluggable connection line. For example, this allows installation time to be drastically reduced due to a pre-installed cable harness. The number of variants can be substantially reduced by subsequent programming as well by having different air performance levels customised accordingly – even at a later point in time. An earth wire can be omitted due to a design in protection class 2. Robust design (ESM): Ten years of field experience with more than 3 million energy saving motors shows that the system is robust, maintenance-free and durable. Depending on environmental conditions, the service life usually exceeds 60,000 hours. The stator, which is hermetically sealed with a coat of plastic, is optimally protected from ambient influences. And the electronics are protected from humidity with a sealed off cover, so that IP 54 protection requirements are fulfilled. Shock loads of more than 50g have no effect on the fan due to the stable design. Certifications: ACi 4400: UL (507), VDE (EN 60950), CSA ESM: All of the approvals required in the refrigerated case industry are present or in progress. VDE: EN 60335-1, -2-24, -2-80, -2-89 UL 1004-1, 1004-3, UL 60730 and GOST 6 The new energy-saving axial fans ACI 4400 8 ESM Size 130, 172 10 ESM Size 200, 230, 250 14 ESM Size 300 28 7 Energy-saving axial fans Series ACi 4400 119 x 119 x 38 mm Input power Current draw Sound pressure level VAC Hz rpm W mA dB(A) Mass Speed/rpm Type Perm. amb. temp. Frequency Nominal data – Bearings: Maintenance-free ball bearings – Motor protection: Via electronics – Moisture protection: Motor and circuit board are coated – Electrical connection: Plug-in connection lateral – Protection class: II – Product conforming to standard: CE – Approvals: UL (507), VDE (EN 60950), CSA Sound power level Nominal voltage range VAC Curve Nominal voltage – Material: Housing: Plastic PBT fibreglass-reinforced Blade: Plastic PA, fibreglass-reinforced – Number of blades: 5 – Direction of air flow: "V", exhaust over struts – Direction of rotation: Clockwise, seen on rotor – Insulation class: "E" – Mounting position: Any – Condensate discharges: None – Mode of operation: Con. operation (S1) Bel(A) °C kg ACi 4420 ML A 1~ 230 195...265 50/60 1850 1,4 17 25 4,1 -20..+75 0,25 ACi 4420 H B 1~ 230 195...265 50/60 3000 3,3 35 39 5,1 -20..+75 0,25 ACi 4420 HH C 1~ 230 195...265 50/60 3350 4,4 41 42 5,3 -20..+75 0,25 ACi 4410 HH D 1~ 115 85...132 50/60 3350 4,4 82 42 5,3 -20..+75 0,25 subject to alterations Air performance measured in H2O Pa Curves as per: ISO 5801, and without protection against D C accidental contact 60 0,2 50 I mA 1 1850 1,4 17 A 2 1850 1,5 18 A 3 1850 1,6 19 A 4 1850 1,7 19 B 1 3000 3,3 35 only valid under the measur- B 2 3000 3,9 39 ment conditions listed and B 3 3000 3,9 44 may vary depending on the B 4 3000 4,7 46 C 1 3350 4,4 41 C 2 3350 5,1 48 C 3 3350 5,7 53 C 4 3350 5,9 55 D 1 3350 4,4 82 D 2 3350 5,1 96 D 3 3350 5,7 106 D 4 3350 5,9 110 The acoustic values given are B Pe W A Installation category A, 70 n rpm installation situation. 40 With any deviation to the standard setup, the specific values 4 have to be checked and re- 30 viewed once installed or fitted! 4 0,1 3 A For detailed information 3 20 see Compact fans catalogue 2 2 4 10 version 2011, p. 8-16 3 2 pfs qV 8 20 0 25 1 60 40 50 75 100 1 125 1 100 80 150 175 cfm m3/h – Electr. connection: L ACi 4400 N 119 ±0.3 104.8 ±0.2 A-A 38 ±0.5 A 6± R 0.3 3 .3 ±0 . 15 0. Ø4 A 6± 0. 3 ±0 .1 5 R 0.3 Ø4 .3 "B" ❮ "V" "A" Plug connection on both sides possible. 9 Accessories p. 44 ff. Energy-saving axial fans Ø 130 – Material: Wall ring: Plastic PP, fibreglassreinforced; Blade:Plastic PA, fibreglass-reinforced – Number of blades: 7 – Direction of air flow: "V", exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Con. operation (S1) Nominal voltage Frequency Speed/rpm(1) Max. input power(1) Max. current draw(1) Max. back pressure Perm. amb. temp. Mass VAC Hz rpm W A Pa °C kg 1~ 115 50/60 3200 24 0,38 90 -30..+60 0,75 1~ 230 50/60 3200 24 0,19 90 -30..+70 0,75 Curve Nominal data Type Motor W1G130-AA49 -01 M1G 055-AI A W1G130-AA25 -01 M1G 055-AI B subject to alterations – Bearings: Maintenance-free ball bearings – Motor protection: Via electronics and TOP – Electrical connection: Plug-in connection on motor side – Protection class: II – Product conforming to standard: CE; EN 60335-1 – Approvals: VDE, UL, CSA, GOST are applied for – Speed: Using the programming unit, 2 speeds between nmin and nmax can be programmed. (1) Nominal data in operating point with maximum load and 115 or 230 VAC Pa in H2O Curves A B 90 Air performance measured as per: ISO 5801, in ebm-papst full nozzle and without protection against 80 accidental contact 60 7 3200 23 0,38 63 2 3200 24 0,38 61 A 3 3200 24 0,38 60 A 4 3200 24 0,38 63 5 2800 16 0,26 60 A 6 2800 16 0,26 58 LWA as per ISO 13347, A 7 2800 16 0,26 57 LpA measured at 1 m distance A 8 2800 16 0,26 60 B 1 3200 23 0,19 63 B 2 3200 24 0,19 61 B 3 3200 24 0,19 60 B 4 3200 24 0,19 63 B 5 2800 16 0,13 60 B 6 2800 16 0,13 58 dard setup, the specific values B 7 2800 16 0,13 57 have to be checked and re- B 8 2800 16 0,13 60 only valid under the measurment conditions listed and 40 may vary depending on the installation situation. 30 0,1 2 With any deviation to the stan- 6 20 viewed once installed or fitted! 10 For detailed information 5 pfs qV 40 50 80 100 n max. = 3200 min-1 10 1 A A The acoustic values given are 0 160 120 150 200 n = 2800 min-1 250 LWA dB(A) to fan axis 0,2 50 3 I A Suction-side noise levels: 0,3 8 70 Pe W A Installation category A, 4 n rpm 200 300 n min. = 1100 min-1 see page 62 ff. 1 350 cfm m3/h – Electr. connection: L1 black Mains supply voltage Energy-saving motor / fan (ESM) blue N Speed selection L1 or N brown S S off on (L1 or N) Speed selection n1 n2 Ø151±0.5 A-A 0. 1 Ø4 Ø5 .2 ± 10 5 1. 58 -1 62 A Ø4 .2 ±0 Ø 5 .1 Ø1 Ø1 7 2± + 0. -0 0.1 5 .3 5 10 1. 55±0.3 40±5 6 450 +20 ❮ "V" A Connection lead (total length 450 mm) is fitted ex works and can be detached. 11 Handheld Programmer p. 41 Energy-saving axial fans Ø 172 – Material: Wall ring: Plastic PP Blade: Plastic PA, fibreglass-reinforced – Number of blades: 5 – Direction of air flow: "V", exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Con. operation (S1) Nominal voltage Frequency Speed/rpm(1) Max. input power(1) Max. current draw(1) Max. back pressure Perm. amb. temp. Mass VAC Hz rpm W A Pa °C kg 1~ 115 50/60 2500 21 0,30 60 -30..+50 0,95 1~ 230 50/60 2500 22 0,18 60 -30..+50 0,95 Curve Nominal data Type Motor W1G172-EC95 -01 M1G 055-BD A W1G172-EC91 -01 M1G 055-BD B subject to alterations – Bearings: Maintenance-free ball bearings – Motor protection: Via electronics and TOP – Electrical connection: Plug-in connection on motor side – Protection class: II – Product conforming to standard: CE – Approvals: VDE, UL, CSA, GOST – Speed: Using the programming unit, 2 speeds between nmin and nmax can be programmed. (1) Nominal data in operating point with maximum load and 115 or 230 VAC Pa in H2O Curves A B Air performance measured as per: ISO 5801, 0,24 60 4 and without protection against 40 0,16 50 0,20 accidental contact 1 2500 20 0,28 62 A 2 2500 21 0,30 63 A 3 2500 21 0,30 63 A 4 2500 21 0,30 63 5 1700 9 0,14 54 A 6 1700 10 0,16 53 LWA as per ISO 13347, A 7 1700 10 0,16 53 LpA measured at 1 m distance A 8 1700 10 0,16 54 B 1 2500 21 0,17 62 B 2 2500 22 0,18 63 B 3 2500 22 0,18 63 B 4 2500 22 0,18 63 B 5 1700 9 0,07 54 B 6 1700 10 0,08 53 dard setup, the specific values B 7 1700 10 0,08 53 have to be checked and re- B 8 1700 10 0,08 54 to fan axis 3 0,12 only valid under the measurment conditions listed and 8 0,04 10 0,08 installation situation. 2 7 With any deviation to the stan- viewed once installed or fitted! 6 For detailed information pfs 0 qV 50 100 n max. = 2500 min-1 12 100 5 200 150 200 300 n = 1700 min-1 see page 62 ff. 1 250 400 LWA dB(A) A may vary depending on the 20 I A Suction-side noise levels: The acoustic values given are 30 Pe W A Installation category A, in ebm-papst full nozzle n rpm 300 500 n min. = 900 min-1 cfm m3/h – Electr. connection: L1 black Mains supply voltage Energy-saving motor / fan (ESM) blue N Speed selection L1 or N brown S S off on (L1 or N) Speed selection n1 n2 78.5 4x Ø4.3 Ø222 Ø208 6 4 40±5 450+20 Ø172 Ø19 2 35 ❮ "V" Connection lead (total length 450 mm) is fitted ex works and can be detached Other lengths available as accessory. 13 Accessories p. 40 ff. Energy-saving axial fans Ø 200 – Material: Wall ring: Plastic PP epylen Blade: Plastic PA, fibreglass-reinforced Number of blades: 5 Direction of air flow: "V", exhaust over struts Direction of rotation: Counter-clockwise, seen on rotor Type of protection: IP 54 Insulation class: "B" Mounting position: Any Condensate discharges: None – Mode of operation: Con. operation (S1) – Bearings: Maintenance-free ball bearings – Motor protection: Via electronics and TOP – Electrical connection: Plug-in connection on motor side – Protection class: II – Product conforming to standard: CE – Approvals: VDE, UL, CSA, GOST – Speed: Using the programming unit, 2 speeds between nmin and nmax can be programmed. A B – – – Frequency Speed/rpm(1) Max. input power(1) Max. current draw(1) Max. back pressure Perm. amb. temp. Mass VAC Hz rpm W A Pa °C kg 1~ 115 50/60 1300 8,0 0,11 23 -30..+50 1,0 1~ 230 50/60 1300 8,0 0,07 23 -30..+50 1,0 Curve Nominal voltage – – – – Nominal data Type Motor W1G200-EC91 -27 M1G 055-BD A W1G200-EC87 -25 M1G 055-BD B subject to alterations (1) Nominal data in operating point with maximum load and 115 or 230 VAC Pa in H2O Curves A B Air performance measured as per: ISO 5801, 0,10 25 and without protection against accidental contact 0,08 3 1 1300 7 0,09 50 A 2 1300 8 0,10 49 A 3 1300 8 0,10 48 A 4 1300 8 0,11 51 A 5 900 3 0,05 41 A 6 900 4 0,05 41 LWA as per ISO 13347, A 7 900 4 0,05 40 LpA measured at 1 m distance A 8 900 4 0,05 41 B 1 1300 7 0,06 50 B 2 1300 8 0,07 49 B 3 1300 8 0,07 48 B 4 1300 8 0,07 51 B 5 900 3 0,03 41 B 6 900 4 0,04 41 dard setup, the specific values B 7 900 4 0,04 40 have to be checked and re- B 8 900 4 0,04 41 The acoustic values given are only valid under the measurment conditions listed and may vary depending on the 8 0,04 10 installation situation. 2 0,02 7 5 With any deviation to the stan- 6 viewed once installed or fitted! For detailed information 5 pfs 0 qV 50 100 n max. = 1300 min-1 14 100 150 200 n = 900 min-1 see page 62 ff. 1 200 300 LWA dB(A) to fan axis 0,06 15 I A Suction-side noise levels: 4 20 Pe W A Installation category A, in ebm-papst full nozzle n rpm 250 400 n min. = 500 min-1 cfm m3/h – Electr. connection: L1 black Mains supply voltage Energy-saving motor / fan (ESM) blue N Speed selection L1 or N brown S S off on (L1 or N) Speed selection n1 n2 78.5 4x Ø4.3 Ø250 Ø236 6 4 40±5 450+20 Ø200 Ø22 0 40 ❮ "V" Connection lead (total length 450 mm) is fitted ex works and can be detached Other lengths available as accessory. 15 Accessories p. 40 ff. Energy-saving axial fans Ø 200 – Material: Wall ring: Plastic PP Blade: Plastic PA, fibreglass-reinforced – Number of blades: 5 – Direction of air flow: "V", exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Con. operation (S1) Nominal voltage Frequency Speed/rpm(1) Max. input power(1) Max. current draw(1) Max. back pressure Perm. amb. temp. Mass VAC Hz rpm W A Pa °C kg 1~ 115 50/60 2100 31 0,46 55 -30..+50 1,0 1~ 230 50/60 2100 31 0,24 55 -30..+50 1,0 Curve Nominal data Type Motor W1G200-EC95 -47 M1G 055-BD A W1G200-EC91 -45 M1G 055-BD B subject to alterations – Bearings: Maintenance-free ball bearings – Motor protection: Via electronics and TOP – Electrical connection: Plug-in connection on motor side – Protection class: II – Product conforming to standard: CE – Approvals: VDE, UL, CSA, GOST – Speed: Using the programming unit, 2 speeds between nmin and nmax can be programmed. (1) Nominal data in operating point with maximum load and 115 or 230 VAC Pa in H2O Curves A B Air performance measured as per: ISO 5801, 0,24 in ebm-papst full nozzle and without protection against accidental contact 40 0,16 50 0,20 4 1 2100 28 0,42 62 A 2 2100 30 0,45 61 A 3 2100 31 0,46 60 A 4 2100 31 0,46 62 5 1500 14 0,22 54 A 6 1500 15 0,22 54 LWA as per ISO 13347, A 7 1500 16 0,26 53 LpA measured at 1 m distance A 8 1500 16 0,26 55 B 1 2100 29 0,22 62 B 2 2100 30 0,23 61 B 3 2100 31 0,24 60 B 4 2100 31 0,24 62 B 5 1500 14 0,11 54 B 6 1500 16 0,12 54 dard setup, the specific values B 7 1500 16 0,13 53 have to be checked and re- B 8 1500 16 0,13 55 to fan axis 3 0,12 only valid under the measurment conditions listed and 8 installation situation. 0,08 7 2 0,04 With any deviation to the stan- 10 6 viewed once installed or fitted! For detailed information pfs 0 qV 50 100 100 n max. = 2100 min-1 16 150 200 200 300 250 400 n = 1500 min-1 5 300 500 see page 62 ff. 1 350 600 n min. = 800 min-1 LWA dB(A) A may vary depending on the 20 I A Suction-side noise levels: The acoustic values given are 30 Pe W A Installation category A, 60 n rpm 400 700 cfm m3/h – Electr. connection: L1 black Mains supply voltage Energy-saving motor / fan (ESM) blue N Speed selection L1 or N brown S S off on (L1 or N) Speed selection n1 n2 78.5 4x Ø4.3 Ø250 Ø236 6 4 40±5 450+20 Ø200 Ø22 0 40 ❮ "V" Connection lead (total length 450 mm) is fitted ex works and can be detached Other lengths available as accessory. 17 Accessories p. 40 ff. Energy-saving axial fans Ø 200 – Material: Wall ring: epylen Blade: Plastic PA, fibreglass-reinforced – Number of blades: 5 – Direction of air flow: "V", exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Con. operation (S1) Nominal voltage Nominal voltage range Speed/rpm(1) Input power(1) current draw(1) Max. back pressure Perm. amb. temp. Mass VDC VDC rpm W A Pa °C kg A 24 16-28 1550 11 0,50 30 -30..+50 1,0 B 24 16-28 2130 29 1,50 55 -30..+50 1,0 Curve Nominal data Type Motor W1G200-EF41 -01 M1G 055-BD W1G200-EF01 -01 M1G 055-BD subject to alterations – Bearings: Maintenance-free ball bearings – Motor protection: Via electronics and TOP – Electrical connection: Plug-in connection on motor side – Protection class: II – Approvals: VDE, UL, CSA, GOST are applied for – Technical features: Control input 0-10 VDC / PWM, Tach output (1) Nominal data running at free air. 70 in H2O Air performance measured as per: ISO 5801, in ebm-papst full nozzle and without protection against 0,24 60 accidental contact 4 0,20 50 B 53 A 3 1510 11 0,51 52 A 4 1515 11 0,51 55 1,50 62 30 1,56 62 LWA as per ISO 13347, B 3 2050 31 1,61 61 LpA measured at 1 m distance B 4 2050 31 1,62 59 0,16 0,12 0,08 With any deviation to the stan- 2 3 0,04 viewed once installed or fitted! 2 For detailed information 200 100 0 pfs 54 0,50 29 may vary depending on the A 1 18 0,50 11 2085 have to be checked and re- qV 11 1530 2130 dard setup, the specific values 10 1550 2 2 installation situation. 20 1 A 1 ment conditions listed and 4 100 200 300 300 400 500 see page 62 ff. 1 400 600 700 500 cfm 800 m3/h LWA dB(A) B only valid under the measur- 30 I A B The acoustic values given are 3 Pe W Suction-side noise levels: to fan axis 40 n rpm A Installation category A, 0,28 Pa Curves – Electr. connection: 1 4 UN +24 VDC UB PWM/0-10 VDC RE>100K Tacho 3 680 R Tacho 47 V GND 2 GND1 Reverse-polarity protection 78.5 4x Ø4.3 Ø250 Ø236 6 4 40±5 450+20 Ø200 Ø22 0 40 ❮ "V" Connection lead (total length 450 mm) is fitted ex works and can be detached Other lengths available as accessory. 19 Accessories p. 41 Electr. connection p. 46 Energy-saving axial fans Ø 200 – Material: Wall ring: epylen Blade: Plastic PA, fibreglass-reinforced – Number of blades: 5 – Direction of air flow: "V", exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Con. operation (S1) Nominal voltage Frequency Speed/rpm(1) Max. input power(1) Max. current draw(1) Max. back pressure Perm. amb. temp. Mass VAC Hz rpm W A Pa °C kg 1~ 230 50/60 1300 8 0,07 23 -30..+50 1,0 1~ 230 50/60 2100 31 0,24 55 -30..+50 1,0 Curve Nominal data Type Motor W1G200-EC87 -A2 M1G 055-BD A W1G200-EC91 -A4 M1G 055-BD B subject to alterations – Bearings: Maintenance-free ball bearings – Motor protection: Via electronics and TOP – Electrical connection: Plug-in connection on motor side – Protection class: II – Product conforming to standard: CE; EN 60335-1 – Approvals: VDE, UL, CSA, GOST are applied for – Technical features: Control input 0-10 VDC / PWM, Output 10 VDC max. 1.1 mA, Tach output (1) Nominal data in operating point with maximum load and 115 or 230 VAC Air performance measured in H2O Pa Curves as per: ISO 5801, 4 0,20 50 and without protection against accidental contact 0,16 3 0,12 0,08 0,04 pfs 20 500 4 1300 8,0 0,07 48 62 B 3 2100 31 0,24 60 LpA measured at 1 m distance B 4 2100 31 0,24 59 see page 62 ff. 1 300 400 48 A LWA as per ISO 13347, For detailed information 300 0,07 62 have to be checked and re- 1 200 8,0 0,24 viewed once installed or fitted! 100 1300 0,23 dard setup, the specific values qV 3 30 installation situation. 2 200 49 A 29 With any deviation to the stan- 100 50 0,07 2100 3 0 0,06 8,0 2100 may vary depending on the 2 A 7,0 1300 2 ment conditions listed and 10 1300 2 1 only valid under the measur- 20 1 A B The acoustic values given are 4 400 600 700 cfm m3/h LWA dB(A) B to fan axis 30 I A Suction-side noise levels: B 40 Pe W A Installation category A, in ebm-papst full nozzle n rpm – Electr. connection: CON10 L AC1 1 N 2 1.25A P AC2 N CON50 +10V 1 Imax=1.1mA 3 10V/PWM 47k 47k 100μF GND 4 2 Tacho 1 680R ZMM47 2 105.5 78.5 Ø4.3(4x) Ø200 Ø236 Ø250 Ø22 0 40 4 40 ±5 6 6 40 ±5 1000 +20 450 +20 ❮ "V" 21 Accessories p. 40 ff. Electr. connection p. 47 Energy-saving axial fans Ø 200 – Material: Blade: Plastic PA, fibreglass-reinforced Guard grille: epylen – Number of blades: 5 – Direction of air flow: "A", intake over guard grille – Direction of rotation: Counter-clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Con. operation (S1) Nominal voltage Frequency Speed/rpm(1) Max. input power(1) Max. current draw(1) Max. back pressure Perm. amb. temp. Mass VAC Hz rpm W A Pa °C kg 1~ 115 50/60 2000 31 0,43 45 -30..+50 0,95 1~ 230 50/60 2000 34 0,26 45 -30..+50 0,95 Curve Nominal data Type Motor S1G 200-CA95 -02 M1G 055-BD A S1G 200-CA91 -02 M1G 055-BD B subject to alterations – Bearings: Maintenance-free ball bearings – Motor protection: Via electronics and TOP – Electrical connection: Plug-in connection on motor side – Protection class: II – Product conforming to standard: CE – Approvals: VDE, UL, CSA, GOST – Speed: Using the programming unit, 2 speeds between nmin and nmax can be programmed. (1) Nominal data in operating point with maximum load and 115 or 230 VAC Air performance measured in H2O Pa Curves A B as per: ISO 5801, 0,20 50 and with protection against accidental contact 0,16 I A LWA dB(A) 1 2000 30 0,43 64 A 2 2000 30 0,43 64 A 3 2000 30 0,43 63 A 4 2000 31 0,43 64 A 5 1500 17 0,28 59 Suction-side noise levels: A 6 1500 18 0,28 58 LWA as per ISO 13347, A 7 1500 19 0,28 58 LpA measured at 1 m distance A 8 1500 20 0,28 59 B 1 2000 32 0,24 64 B 2 2000 33 0,25 64 B 3 2000 33 0,25 63 B 4 2000 34 0,26 64 B 5 1500 18 0,16 59 B 6 1500 19 0,16 58 dard setup, the specific values B 7 1500 19 0,16 58 have to be checked and re- B 8 1500 20 0,16 59 4 40 Pe W A Installation category A, in ebm-papst short nozzle n rpm 30 0,12 to fan axis The acoustic values given are 3 only valid under the measur8 ment conditions listed and 20 0,08 may vary depending on the installation situation. 7 With any deviation to the stan- 10 0,04 2 6 viewed once installed or fitted! For detailed information 5 pfs 0 qV 50 100 100 n max. = 2000 min-1 22 150 200 200 300 250 400 n = 1500 min-1 300 500 see page 62 ff. 1 350 600 n min. = 800 min-1 400 700 cfm m3/h – Electr. connection: L1 black Mains supply voltage Energy-saving motor / fan (ESM) blue N Speed selection L1 or N S off on (L1 or N) Speed selection n1 n2 38.5 3 4x Ø6.5 6 "A" ❯ 380 ±20 40±5 37.5 Ø260 Ø278 Ø200 40 brown S Connection lead (total length 450 mm) is fitted ex works and can be detached Other lengths available as accessory. 23 Accessories p. 40 ff. Energy-saving axial fans Ø 230 – Material: Wall ring: Plastic PP Blade: Plastic PA, fibreglass-reinforced – Number of blades: 5 – Direction of air flow: "V", exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Con. operation (S1) Nominal voltage Frequency Speed/rpm(1) Max. input power(1) Max. current draw(1) Max. back pressure Perm. amb. temp. Mass VAC Hz rpm W A Pa °C kg 1~ 115 50/60 1500 23 0,35 36 -30..+50 1,05 1~ 230 50/60 1500 26 0,20 36 -30..+50 1,05 Curve Nominal data Type Motor W1G230-EB97 -01 M1G 055-BD A W1G230-EB89 -01 M1G 055-BD B subject to alterations – Bearings: Maintenance-free ball bearings – Motor protection: Via electronics and TOP – Electrical connection: Plug-in connection on motor side – Protection class: II – Product conforming to standard: CE – Approvals: VDE, UL, CSA, GOST – Speed: Using the programming unit, 2 speeds between nmin and nmax can be programmed. (1) Nominal data in operating point with maximum load and 115 or 230 VAC Pa in H2O Curves Air performance measured A as per: ISO 5801, B 0,16 40 and without protection against accidental contact 30 0,12 4 3 1 1500 23 0,35 58 A 2 1500 23 0,35 58 A 3 1500 23 0,35 58 A 4 1500 23 0,35 57 5 1000 9 0,15 48 A 6 1000 10 0,16 48 LWA as per ISO 13347, A 7 1000 10 0,16 48 LpA measured at 1 m distance A 8 1000 10 0,16 48 B 1 1500 24 0,19 58 B 2 1500 25 0,19 58 B 3 1500 25 0,19 58 B 4 1500 26 0,20 57 B 5 1000 10 0,09 48 B 6 1000 11 0,09 48 dard setup, the specific values B 7 1000 11 0,10 48 have to be checked and re- B 8 1000 11 0,10 48 to fan axis 0,08 ment conditions listed and may vary depending on the installation situation. 8 2 7 0,04 With any deviation to the stan- viewed once installed or fitted! 6 For detailed information 5 pfs 0 qV 100 200 n max. = 1500 min-1 24 200 300 400 n = 1000 min-1 1 400 600 LWA dB(A) A only valid under the measur- 10 I A Suction-side noise levels: The acoustic values given are 20 Pe W A Installation category A, in ebm-papst full nozzle n rpm 500 800 n min. = 700 min-1 cfm m3/h see page 62 ff. – Electr. connection: L1 black Mains supply voltage Energy-saving motor / fan (ESM) blue N Speed selection L1 or N brown S S off on (L1 or N) Speed selection n1 n2 78.5 4x Ø4.3 Ø280 Ø266 6 4 40±5 450+20 Ø230 Ø25 0 50 ❮ "V" Connection lead (total length 450 mm) is fitted ex works and can be detached Other lengths available as accessory. 25 Accessories p. 40 ff. Energy-saving axial fans Ø 250 M1G 055-BI B subject to alterations Mass W1G250-BB17 -01 Perm. amb. temp. A Max. back pressure M1G 055-BI Max. current draw(1) W1G250-BB21 -01 Max. input power(1) Motor Speed/rpm(1) Type Frequency Nominal data – Bearings: Maintenance-free ball bearings – Motor protection: Via electronics and TOP – Electrical connection: Plug-in connection on motor side – Protection class: II – Product conforming to standard: CE – Approvals: VDE, UL, CSA, GOST – Speed: Using the programming unit, 2 speeds between nmin and nmax can be programmed. Nominal voltage Curve – Material: Wall ring: Plastic PP Blade: Plastic PA, fibreglass-reinforced – Number of blades: 5 – Direction of air flow: "V", exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Con. operation (S1) VAC Hz rpm W A Pa °C kg 1~ 115 50/60 1700 32 0,47 40 -30..+50 1,55 1~ 230 50/60 1700 32 0,24 40 -30..+50 1,55 (1) Nominal data in operating point with maximum load and 115 or 230 VAC Pa in H2O Curves A B Air performance measured as per: ISO 5801, 30 0,16 4 accidental contact 0,12 40 and with protection against 3 1 1700 30 0,44 62 A 2 1700 31 0,45 63 A 3 1700 32 0,47 64 A 4 1700 32 0,47 65 A 5 1200 14 0,22 53 A 6 1200 15 0,24 54 LWA as per ISO 13347, A 7 1200 16 0,25 55 LpA measured at 1 m distance A 8 1200 17 0,26 57 B 1 1700 30 0,24 62 B 2 1700 31 0,24 63 B 3 1700 32 0,24 64 B 4 1700 32 0,24 65 B 5 1200 14 0,12 53 B 6 1200 15 0,13 54 dard setup, the specific values B 7 1200 16 0,14 55 have to be checked and re- B 8 1200 17 0,14 57 only valid under the measur- 0,08 ment conditions listed and may vary depending on the installation situation. 7 2 0,04 With any deviation to the stan- 6 viewed once installed or fitted! For detailed information 5 pfs 0 qV 100 200 n max. = 1700 min-1 26 200 300 400 1 400 600 n = 1200 min-1 500 800 n min. = 900 min-1 LWA dB(A) to fan axis 8 10 I A Suction-side noise levels: The acoustic values given are 20 Pe W A Installation category A, in ebm-papst full nozzle n rpm cfm 1000 m3/h see page 62 ff. – Electr. connection: L1 black Mains supply voltage Energy-saving motor / fan (ESM) blue N Speed selection L1 or N brown S S off on (L1 or N) Speed selection n1 n2 92 80 296 4x90˚ 4 Ø280 Ø250 4xØ7 45˚ 95 Ø2 315 Ø 40±5 6 ❮ "V" 340 ±20 27 Accessories p. 40 ff. Energy-saving axial fans Ø 300 – Material: Wall ring: Plastic PP Blade: Plastic PA, fibreglass-reinforced – Number of blades: 5 – Direction of air flow: "V", exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Con. operation (S1) Nominal voltage Frequency Speed/rpm(1) Max. input power(1) Max. current draw(1) Max. back pressure Perm. amb. temp. Mass VAC Hz rpm W A Pa °C kg 1~ 115 50/60 1300 35 0,50 35 -30..+50 1,75 1~ 230 50/60 1300 35 0,27 35 -30..+50 1,75 Curve Nominal data Type Motor W1G300-BB23 -01 M1G 055-BI A W1G300 -BB19 -01 M1G 055-BI B subject to alterations – Bearings: Maintenance-free ball bearings – Motor protection: Via electronics and TOP – Electrical connection: Plug-in connection on motor side – Protection class: II – Product conforming to standard: CE – Approvals: VDE, UL, CSA, GOST – Speed: Using the programming unit, 2 speeds between nmin and nmax can be programmed. (1) Nominal data in operating point with maximum load and 115 or 230 VAC Pa in H2O Curves A B as per: ISO 5801, 4 in ebm-papst full nozzle and with protection against accidental contact 25 0,10 3 I A LWA dB(A) 1 1300 28 0,41 58 A 2 1300 31 0,46 58 A 3 1300 32 0,47 57 A 4 1300 35 0,50 58 A 5 900 12 0,24 50 Suction-side noise levels: A 6 900 14 0,25 49 LWA as per ISO 13347, A 7 900 15 0,26 49 LpA measured at 1 m distance A 8 900 16 0,27 50 B 1 1300 32 0,25 58 B 2 1300 34 0,27 58 B 3 1300 34 0,27 57 B 4 1300 35 0,27 58 B 5 900 13 0,12 50 B 6 900 14 0,13 49 dard setup, the specific values B 7 900 15 0,14 49 have to be checked and re- B 8 900 16 0,15 50 0,12 30 Pe W A Installation category A, 0,14 35 Air performance measured n rpm 20 0,08 to fan axis The acoustic values given are only valid under the measurment conditions listed and 0,06 8 15 may vary depending on the 2 installation situation. 10 0,04 7 With any deviation to the stan- 6 viewed once installed or fitted! 0,02 5 For detailed information 5 pfs 0 qV 100 200 200 n max. = 1300 min-1 28 300 400 400 600 500 800 n = 900 min-1 see page 62 ff. 1 600 1000 700 1200 n min. = 700 min-1 800 cfm m3/h – Electr. connection: L1 black Mains supply voltage Energy-saving motor / fan (ESM) blue N Speed selection L1 or N brown S S off on (L1 or N) Speed selection n1 n2 92 80 4 45˚ Ø350 Ø300 4xØ6.3 360 4x90˚ 80 Ø3 397 Ø 40±5 6 ❮ "V" 290 ±20 29 Accessories p. 40 ff. Energy-saving axial fans Ø 300 – Material: Blade: Plastic PA, fibreglass-reinforced Guard grille: epylen – Number of blades: 5 – Direction of air flow: "A", intake over guard grille – Direction of rotation: Counter-clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Con. operation (S1) Nominal voltage Frequency Speed/rpm(1) Max. input power(1) Max. current draw(1) Max. back pressure Perm. amb. temp. Mass VAC Hz rpm W A Pa °C kg 1~ 115 50/60 1250 35 0,56 35 -30..+50 1,4 1~ 230 50/60 1250 35 0,27 35 -30..+50 1,4 Curve Nominal data Type Motor S1G 300-CA23 -02 M1G 055-BI A S1G 300-CA19 -02 M1G 055-BI B subject to alterations – Bearings: Maintenance-free ball bearings – Motor protection: Via electronics and TOP – Electrical connection: Plug-in connection on motor side – Protection class: II – Product conforming to standard: CE – Approvals: VDE, UL, CSA, GOST – Speed: Using the programming unit, 2 speeds between nmin and nmax can be programmed. (1) Nominal data in operating point with maximum load and 115 or 230 VAC Air performance measured in H2O Pa Curves A B as per: ISO 5801, 0,16 40 and with protection against accidental contact 30 0,12 4 1 1250 31 0,45 64 A 2 1250 32 0,47 62 A 3 1250 32 0,48 62 A 4 1250 35 0,56 63 A 5 900 13 0,24 55 A 6 900 14 0,26 54 LWA as per ISO 13347, A 7 900 16 0,30 53 LpA measured at 1 m distance A 8 900 17 0,32 54 B 1 1250 27 0,21 64 B 2 1250 30 0,23 62 B 3 1250 32 0,24 62 B 4 1250 35 0,27 63 B 5 900 13 0,12 55 B 6 900 14 0,13 54 dard setup, the specific values B 7 900 16 0,15 53 have to be checked and re- B 8 900 17 0,16 54 The acoustic values given are 0,08 ment conditions listed and may vary depending on the 8 installation situation. 2 With any deviation to the stan- 0,04 7 6 viewed once installed or fitted! For detailed information pfs 0 qV 100 200 n max. = 1250 min-1 30 LWA dB(A) Suction-side noise levels: only valid under the measur- 10 I A to fan axis 3 20 Pe W A Installation category A, in ebm-papst short nozzle n rpm 200 300 400 5 500 400 600 n = 900 min-1 800 see page 62 ff. 1 600 1000 n min. = 700 min-1 700 cfm 1200 m3/h – Electr. connection: L1 black Mains supply voltage Energy-saving motor / fan (ESM) blue N Speed selection L1 or N 43 3 S off on (L1 or N) Speed selection n1 n2 4x Ø6.5 40±5 6 "A" ❯ 330 ±20 38 Ø360 Ø377 Ø300 45 brown S Connection lead (total length 450 mm) is fitted ex works and can be detached Other lengths available as accessory. 31 Accessories p. 40 ff. The perfect combination! For the new energy saving centrifugal modules, we have combined a backward curved centrifugal impeller already established on the market with new compact modules. The result is a highly compact unit with an integrated inlet nozzle and motor suspension directly connected to the mounting plate. The mounting plate, inlet nozzle and motor suspension consist of a robust and durable plastic. This has the advantage that no compromises have to be made in the aero-acoustic design. The energy saving centrifugal modules are available with impellers with a 190 and 220 mm diameter. They are extremely compact and easy to install. Intricate adjustments to the impeller for the nozzle are not necessary. An inlet side guard grille is available for installation as an accessory. The new diagonal K1G200 with an energy saving motor rounds out the series. The diagonal impeller design particularly distinguishes itself through its noise-optimised and air flow-optimised performance in the medium pressure range and sets new benchmarks in the process. Take advantage of the benefits offered by a completely pre-installed functional unit: – Compact design – Optimised, tested and guaranteed functional unit – Plug-and-play characteristic – Easy installation – Energy saving motor (ESM) – Optional guard grille – Simple logistics Maximum efficiency The energy saving motors achieve a maximum efficiency of over 70%. So they only need 1/3 to 1/6 the power of an otherwise normal shaded-pole motor. But higher efficiency also means lower intrinsic heating during operation at the same time, which dissipates less heat into the surrounding area. This means that less cooling power must be generated from the outset, thus resulting in additional energy savings. 32 The new energy-saving centrifugal modules Size 190, backward curved 34 Size 220, backward curved 36 Size 200, diagonal 38 33 EC centrifugal module backward curved, Ø 190 – Material: Housing: Plastic PA, fibreglass-reinforced Impeller: Plastic PA, fibreglass-reinforced Rotor: Galvanised – Number of blades: 7 – Direction of rotation: clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None, open rotor – Mode of operation: Con. operation (S1) Frequency Speed/rpm(1) Max. input power(1) Max. current draw(1) Type Motor K1G 190 M1G 055-BD A K1G 190 M1G 055-BD B subject to alterations Perm. amb. temp. Nominal voltage VAC Hz rpm W A °C 1~ 115 50/60 2000 30 0,45 -30..+50 1~ 230 50/60 2000 30 0,24 -30..+50 Curve Nominal data – Bearings: Maintenance-free ball bearings – Motor protection: Via electronics and TOP – Electrical connection: Plug-in connection on motor side – Protection class: II – Product conforming to standard: CE – Approvals: VDE, UL, CSA, GOST are applied for – Speed: Using the programming unit, 2 speeds between nmin and nmax can be programmed. (1) Nominal data in operating point with maximum load and 115 or 230 VAC Air performance measured in H2O Pa Curves A B as per: ISO 5801, 0,7 without protection against accidental contact 0,6 4 0,4 3 100 8 1 2000 21 0,34 62 2 2000 25 0,38 60 A 3 2000 30 0,45 59 A 4 2000 26 0,39 60 5 1600 13 0,19 57 A 6 1600 15 0,25 55 LpA measured at 1 m distance A 7 1600 17 0,27 53 to fan axis A 8 1600 15 0,26 55 The acoustic values given are B 1 2000 21 0,16 62 only valid under the measur- B 2 2000 25 0,19 60 B 3 2000 30 0,24 59 B 4 2000 26 0,20 60 B 5 1600 13 0,10 57 B 6 1600 15 0,11 55 have to be checked and re- B 7 1600 17 0,13 53 viewed once installed or fitted! B 8 1600 15 0,12 55 may vary depending on the 0,3 installation situation. 7 60 With any deviation to the stan- 2 0,2 dard setup, the specific values 40 6 0,1 20 A ment conditions listed and 80 For detailed information see page 62 ff. 5 pfs 0 qV 50 100 n max. = 2000 min-1 34 100 150 200 n = 1600 min-1 1 200 300 250 400 n min. = 700 min-1 cfm m3/h LWA dB(A) LWA as per ISO 13347, Suction-side noise levels: 0,5 120 I A A 160 140 Pe W A Installation category A, 180 n rpm – Electr. connection: L1 black Mains supply voltage Energy-saving motor / fan (ESM) blue N Speed selection L1 or N brown S off on (L1 or N) n1 n2 Mass of centrifugal module with support bracket S Speed selection Centrifugal module with support bracket kg K1G 190-AD50 -02 1,3 K1G 190-AD73 -02 1,3 109 94 16.5° 4xØ4.3 5° 4 6 4 40±5 450+20 Ø190 Ø266 Ø280 Ø256+1 8x Connection lead (total length 450 mm) is fitted ex works and can be detached Other lengths available as accessory. 35 Accessories p. 40 ff. EC centrifugal module backward curved, Ø 220 – Material: Housing: Plastic PA, fibreglass-reinforced Impeller: Plastic PA, fibreglass-reinforced Rotor: Galvanised – Number of blades: 11 – Direction of rotation: clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None, open rotor – Mode of operation: Con. operation (S1) Frequency Speed/rpm(1) Max. input power(1) Max. current draw(1) Type Motor K1G 220 M1G 055-BD A K1G 220 M1G 055-BD B subject to alterations Perm. amb. temp. Nominal voltage VAC Hz rpm W A °C 1~ 115 50/60 1600 32 0,50 -30..+50 1~ 230 50/60 1600 33 0,25 -30..+50 Curve Nominal data – Bearings: Maintenance-free ball bearings – Motor protection: Via electronics and TOP – Electrical connection: Plug-in connection on motor side – Protection class: II – Product conforming to standard: CE – Approvals: VDE, UL, CSA, GOST are applied for – Speed: Using the programming unit, 2 speeds between nmin and nmax can be programmed. (1) Nominal data in operating point with maximum load and 115 or 230 VAC Air performance measured in H2O Pa Curves A B without protection against accidental contact 80 0,40 100 3 1 1600 18 0,25 59 A 2 1600 26 0,37 57 A 3 1600 32 0,50 55 A 4 1600 30 0,44 56 5 1200 7 0,10 52 A 6 1200 11 0,15 50 LpA measured at 1 m distance A 7 1200 13 0,18 48 to fan axis A 8 1200 12 0,18 50 The acoustic values given are B 1 1600 18 0,14 59 only valid under the measur- B 2 1600 25 0,21 57 B 3 1600 33 0,25 55 B 4 1600 30 0,25 56 B 5 1200 7 0,06 52 B 6 1200 10 0,08 50 have to be checked and re- B 7 1200 13 0,11 48 viewed once installed or fitted! B 8 1200 12 0,10 50 0,24 may vary depending on the 60 installation situation. 7 2 0,16 With any deviation to the stan- 40 dard setup, the specific values 20 0,08 6 For detailed information see page 62 ff. 5 pfs 0 qV 50 100 n max. = 1600 min-1 36 100 150 200 200 300 n = 1200 min-1 250 400 1 300 500 n min. = 600 min-1 cfm m3/h LWA dB(A) A ment conditions listed and 8 I A LWA as per ISO 13347, Suction-side noise levels: 0,32 120 0,48 4 Pe W A Installation category A, 0,56 140 as per: ISO 5801, n rpm – Electr. connection: L1 black Mains supply voltage Energy-saving motor / fan (ESM) blue N Speed selection L1 or N brown S off on (L1 or N) n1 n2 Mass of centrifugal module with support bracket S Speed selection Centrifugal module with support bracket kg K1G 220-AF90 -02 1,4 K1G 220-AF92 -02 1,4 113 105 ° 4x90 28.5° 4 40±5 6 450+20 Ø220 Ø 295 Ø 310 Ø281+1 4x Ø4.3 Connection lead (total length 450 mm) is fitted ex works and can be detached Other lengths available as accessory. 37 Accessories p. 40 ff. EC centrifugal module diagonal, Ø 200 K1G 200 M1G 055-BD B subject to alterations Perm. amb. temp. A Max. back pressure M1G 055-BD Max. current draw(1) K1G 200 Max. input power(1) Motor Speed/rpm(1) Type Frequency Nominal data – Bearings: Maintenance-free ball bearings – Motor protection: Via electronics and TOP – Electrical connection: Plug-in connection on motor side – Protection class: II – Product conforming to standard: CE – Approvals: VDE, UL, CSA, GOST are applied for – Speed: Using the programming unit, 2 speeds between nmin and nmax can be programmed. Nominal voltage Curve – Material: Housing: Plastic PA, fibreglass-reinforced Blades: Plastic PA, fibreglass-reinforced – Number of blades: 7 – Direction of rotation: clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None, open rotor – Mode of operation: Con. operation (S1) VAC Hz rpm W A PA °C 1~ 115 50/60 2000 31 0,50 120 -30..+50 1~ 230 50/60 2000 35 0,30 120 -30..+50 (1) Nominal data in operating point with maximum load and 115 or 230 VAC in H2O Air performance measured A B as per: ISO 5801, 120 without protection against 4 accidental contact 0,4 80 1 2000 27 0,38 63 2 2000 29 0,42 62 A 3 2000 31 0,50 62 A 4 2000 30 0,43 62 5 1500 14 0,22 57 A 6 1500 16 0,24 56 LpA measured at 1 m distance A 7 1500 17 0,26 55 to fan axis A 8 1500 16 0,25 55 The acoustic values given are B 1 2000 31 0,24 63 only valid under the measur- B 2 2000 33 0,26 62 B 3 2000 35 0,30 62 B 4 2000 35 0,27 62 B 5 1500 16 0,13 57 B 6 1500 19 0,14 56 have to be checked and re- B 7 1500 20 0,18 55 viewed once installed or fitted! B 8 1500 18 0,14 55 0,3 may vary depending on the 0,2 installation situation. 7 40 With any deviation to the stan- 2 0,1 dard setup, the specific values 6 20 For detailed information see page 62 ff. pfs 0 qV 50 100 n max. = 2000 min-1 38 100 150 200 5 250 200 300 n = 1500 min-1 400 1 300 500 n min. = 700 min-1 cfm m3/h LWA dB(A) A ment conditions listed and 60 I A A 3 8 Pe W LWA as per ISO 13347, Suction-side noise levels: 100 n rpm A Installation category A, 0,5 Pa Curves – Electr. connection: L1 black Mains supply voltage Energy-saving motor / fan (ESM) blue N Speed selection L1 or N brown S off on (L1 or N) n1 n2 Mass of centrifugal module with support bracket S Speed selection Centrifugal module with support bracket kg K1G 200-AA95 -02 1,2 K1G 200-AA73 -02 1,2 4xØ5 6 450+20 40±5 4 78.5 Ø236 Ø250 Ø220 4xØ4.3 Connection lead (total length 450 mm) is fitted ex works and can be detached Other lengths available as accessory. 39 Accessories p. 40 ff. Connection leads (ESM) a – Design: Cable conforms to UL standards, sealed plug. Custom-built connection leads on request. 10 40 31,5 22,5 27,5 6 9,3 Jacketed cable, internal line (UL Style 2464/1061) 3 x AWG20 (approx. 0.5 mm2) Brass lead tips Connection lines for energy-saving motors 115/230 VAC Part no. a 10637-4-1040 450 10640-4-1040 600 10638-4-1040 1500 10639-4-1040 2000 subject to alterations Guard grilles (ESM) a b Guard grille (sucking side) for energy-saving centrifugal modules Part no. Size a b 19051-2-2929 190 133,0 9,0 22051-2-2929 220 166,0 8,7 subject to alterations 40 – Material: Plastic PA, fibreglass-reinforced Connection leads (ESM) a – Design: Cable conforms to UL standards, sealed plug. Custom-built connection leads on request. 10 40 31,5 22,5 27,5 6 9,3 Jacketed cable, internal line (UL Style 2464/1061) 4 x AWG20 (approx. 0.5 mm2) Brass lead tips Connection lines for energy-saving motors 24 VDC Part no. a 10710-4-1040 450 10711-4-1040 1500 subject to alterations Handheld Programmer – Easy speed programming – Battery operated – User-friendly navigation menu – Protective boot with kickstand For Energy Saving Motor (ESM) based products Part no. CBC 000-AF08-01 subject to alterations Makes quick work of programming the two ESM selectable operating speeds. Eliminates the need for a personal computer, software, power adapter and 2nd cable. Good for production line or field service use. Automatic shut-off function for an extended battery life. Mini-USB connector for uploading software upgrades. Batteries, programming cable and operating manual included. 41 Pressure sensor for pressure-controlled speed control Setting range cut-off Factory setting cut-off Test pressure Max. operating pressure Max. medium temperature Perm. amb. temp. Mass Part no. Max. power input Nominal data Nominal voltage – Material: Housing made of PA Pressure connection made of brass – Type of protection: IP 65 according to EN 60529 / IEC 529 – Suitable for commonly used refrigerants ( A R134A; B R407C, R404A, R507) – Easy installation via pressure connection with 7/16”-20 UNF female thread with Schrader valve opener – Power supply via10 VDC – 0-10 VDC control output signal for pressure-dependent speed control of the fan – Delivered in individual packaging VDC mA bar bar bar bar °C °C g 40100-4-7380 A 10 1 4 to12.5 7.8 30 27 70 -20 to +65 125 40101-4-7380 B 10 1 10 to 21 15.5 36 32 70 -20 to +65 125 subject to alterations Connecting cable with plug (1.5 m) not included in scope of delivery. Part No.: 24010-4-1040 1 4 2 70 (55) 54 1 = Signal 0-10 V 2 = 10 V 4 = GND 15 – Electr. connection: Connection Pressure sensor 20 fan L 39 N 48 AC1 2AT P AC2 N PE PE1 2 Control voltage 0-10 VDC +10V Imax=1.1mA 1 10V/PWM 47k 47k 1μF 4 Hysteresis GND Tacho Proportional band 1 bar ZMM47 Cut-off 42 3 1 4 2 680R Condensation pressure, bar Connection lead (Pressure sensor) 45.5±0.5 – Design: Single packed in plastic bag. 1500 ±20 70 ±10 31 ±0.5 28.3 ±0.5 6 Jacketed cable, internal line (UL Style 2464), 4 x AWG18 Brass lead tips Connection line for pressure sensor Part no. 24010-4-1040 a 1500 subject to alterations 43 Guard grilles (ACi) – Guard grille acc. to DIN EN ISO 13857 (previously EN 294), made of galvanised or nickelplated and passivated steel wire for device fans. – Additional guard grilles that do not conform to DIN EN ISO 13857 are available on request. – Our guard grilles are specially designed for use with ebm-papst fans. Their design ensures maximum safety with minimum effect on the operating noise level. Note that when using guard grilles from other manufacturers, compliance with safety-related distances will not always be present. LZ30 Fan size 119 x 119 Guard grilles LZ30 Intake side ACi 4400 LZ30 Outlet side 153,5 ±1 ACi 4400 115 ±1 Fan series 3±0,25 4,3+0,2 Connector cables (ACi) 5+1 – Connector cable with injection-moulded plug in various lengths. – Strand ends with core-crimping sleeve, core-end sleeve or tin-plated. L1 (mm) Leads Plug Leads end Lead colour Receptacle for tabs 610 0,5 mm2 0,5 mm2 straight C black/black 2,8 x 0,5 AC straight A black/black 2,8 x 0,5 AC 0,5 mm2 0,5 mm2 straight B black/black 2,8 x 0,5 AC straight A black/black 2,8 x 0,5 AC 0,5 mm2 0,5 mm2 straight C black/black 2,8 x 0,5 AC straight B black/black 2,8 x 0,5 AC 0,82 mm2 straight C black/black 2,8 x 0,5 AC LZ120 LZ120-4 2 000 LZ120-16 800 LZ120-18 4 000 LZ126 1 000 LZ127 1 600 LZ130-1 610 Leads end A Tin-plated Leads end B Core end sleeve 6 44 10+5 –2 Application Leads end C »Ø1,5 Core crimp sleeve »Ø1,5 Plug model 6 Fan filter guard drilles (ACi) – Filter guard grille consisting of 3 parts: outer grille barrier, inner fastening plate and replaceable filter mat. – Grille barrier made of moulded polycarbonate (PC), with matted surface. – Fast and easy exchange of filter mat via a quick release on the grille barrier. – Fastening plate made of wire netting, with black powder coating. – Filter mat can be replaced while the fan is running, protection provided by welded wire netting. – Filter mat made of white, synthetically bonded fibres. Protection filter Fan size FF119 119 x 119 mm A B C 162 136 18,5 D 104,5 Replacement filter* RF 119 * Replacement filters only in packs of 5. FF 119 Fan size: 119 x 119 mm Filter capacity A fan filter guard filters out up to 75% of dust particles up to a size of 5-10 microns and withstands temperatures of up to 100°C. Flame retardant in accordance with DIN 53438, grade F1. For installed, clean filters, an air flow reduction of 20 – 30% can be assumed. 45 Electrical connections W1G 200 - EF41 - 01 / W1G 200 - EF01 - 01 Customer circuit Full speed Connection Speed setting with fixed resistance Speed setting 1 4 Fan / Motor UN +24 VDC 1 UB 1 4.7K 1-10V 4 2 10V -> n = max 1V -> n = min < 1V -> n = 0 Safe start up at Unom -30% from 40% PWM PWM/0-10 VDC 4 4 RE>100K 10K 2 Tacho 3 680 R 47 V Speed setting via PWM 1-10kHz GND Setting of values via ebm temperature controller GND1 2 Reverse-polarity protection 1 P 1 33K 4 OUT 4 N 12V T 2 2 100% PWM -> n = max 10% PWM -> n = min < 10% PWM -> n = 0 Safe start-up at Unom -30% from 40% PWM Line No. Connection Colour Assignment / function 1 1 Un +24 VDC red Power supply 24 VDC, residual ripple 3.5 %, see type plate for voltage range 1 2 GND blue Reference ground 1 3 Tacho white Tacho output: Open Collector, 1 pulse per revolution, Isink max = 10 mA 1 4 PWM / 0-10 VDC yellow 46 Tacho Control input PWM or 0-10 V, RE > 100K Electrical connections W1G 200 - EC87 - A2 / W1G 200 - EC91 - A4 Customer circuit Connection Fan / Motor CON10 max. speed Adjustable speed L 1 50.1 1.25A 50.3 AC1 P AC2 N N 1-10V 2 50.3 50.4 10V -> n = max 1V -> n = min < 1V -> n = 0 CON50 +10V 1 Imax=1.1mA 10V/PWM 3 47k Speed setting via PWM 1-10kHz Speed setting via potentiometer 47k 100μF GND 4 15V Tacho 50.1 1 2 680R 2 Imax=10mA ZMM47 50.3 50.3 10K 12V 50.4 50.4 100% PWM -> n = max 10% PWM -> n = min < 10% PWM -> n = 0 Line No. Connection Colour Assignment / function CON10 1 L black Power supply 230 VAC, 50 - 60 Hz, see type plate for voltage range CON10 2 N blue Neutral conductor CON50 1 10V/max.1.1mA red Voltage output 10V / 1.1mA, electrically isolated CON50 2 Tacho white Tacho output: Open Collector, 1 pulse per revolution, electrically isolated CON50 3 0-10V PWM yellow Control input 0 - 10 V or PWM, electrically isolated CON50 4 GND blue GND - Connection for control interface 47 The smart way to save energy Classic shaded-pole motors (Q motors) have reached the end of their usefulness. The new iQ motors are just as compact, but they are significantly more intelligent, energy-saving and environmentally friendly. Thanks to ebm-papst GreenTech EC technology, the efficiency has been increased by some 70 %. This means that the switch pays off extremely quickly. And that’s not all: With the additional functions of the latest iQ² generation, you can increase the efficiency even more with intelligent control options. Exchange your old motor for 70 % more efficiency From the outside, the iQ and iQ² motors are barely distinguishable from conventional shaded-pole motors. Thus the identical dimensions enable easy replacement without structural modifications or other obstacles. Axial impellers with diameters from 154 to 300 mm can be installed on the iQ motor as usual. The same applies to the mounting flange, the wall ring and the guard grille. Thus the efficiency of many applications can be increased drastically without any development effort. One design – thousands of applications Just one design is compatible with the entire range of impellers, from 154 to 300 mm. This makes logistics easier and keeps your development effort low. Moreover, the smallest size, the iQ 3608, is the most compact version of an EC motor in the area of refrigeration technology. With an axial installation depth of only 74 mm, it guarantees the bit of air that is so badly needed in tight spaces. Energy-saving and quiet – throughout its long service What all variants have in common is their low-noise performance and very long service life. A critical role is played by a particularly low-friction bearing system with ball bearings. This enables the iQ motors to continue to deliver their enormous savings potential for a very long time. All advantages at a glance – High efficiency of up to 70 % – Constant speed, even in the event of voltage fluctuations – High running smoothness due to low-friction bearing system – Intelligent electronics with n-control, overload and locked-rotor protection – Conventional AC technology can be replaced easily – Identical accessories and dimensions to Q motor – Long service life due to maintenance-free ball bearings – One solution replaces multiple sizes of comparable AC motors – Available in 24 V, 115 V and 230 V 48 The new generation of iQ motors Quadratic. Practical. Intelligent. Savings potential 51 Technical data 52 Air performance curves 56 49 The smart square: The new additional functions of the iQ² The new iQ² motors can do everything the “normal” iQ motors can do – and more, which makes applications such as those in refrigeration technology more efficient. Additional functions enable different operating modes, like one that is customised to your needs or automated reverse operation. Simply select the motor variant that best suits your application. iQ² safety class II. iQ² reverse on start. iQ² reverse on demand. iQ² two speeds. The iQ² safety class II features a The iQ² reverse on start runs back- With the iQ² reverse on demand, The special performance feature of special design with plastic housing wards automatically for a pre-pro- you determine the time and the iQ² two speeds is its two factory- parts. This makes extra steps such grammed time at each start-up. duration of the reverse operation. programmed speed steps. For ex- as installing the protective earth This is an important function for For example, you can use the ample, if you want your application conductor (protection class II) cooling units, as it allows accumu- defrost cycle of the evaporator to run in different daytime and unnecessary – and saves you a lot lated dust to be blown from the heat to eliminate dust from the heat nighttime modes to save additional of money. exchanger of the condenser – for exchanger of the condenser. energy, it is the right choice. long-lasting high cooling capacity. General overview of data: iQ and iQ² Material: Die-cast aluminium housing Protection class: I, for iQ² plastic housing II on request Direction of air flow: Sucking or blowing Approvals: UL, TÜV in accordance with DIN EN Direction of rotation: (depending on axial impeller used) 60335-2-24, DIN EN 60335-2-89, Counterclockwise, seen on shaft end DIN EN 60075-15, in progress for iQ² System of protection: IP54 Insulation class: "H" Mounting position: Any Mode of operation: Continuous operation (S1) Bearings: Maintenance-free ball bearings and M4 screw is used to secure the Motor protection: Via electronics impeller on the motor shaft Electrical connection: Mains cable 50 Mounting attachment parts: Guard grille and wall ring are attached to the projecting thread ends on the A side Axial impeller attachment: A plastic adapter with catching peg iQ – Intelligence that pays A quick example calculation: A typical supermarket operates 200 AC fans with 200 mm blades (blade angle 28°) in its refrigeration units. If the shaded-pole motors were to be replaced by iQ or iQ² motors, the energy consumption would be reduced by 39 megawatt hours. That is an annual saving of more than 5.000 euros* and a good 23 tonnes of CO2. Reduction in Annual reduction Annual reduction Annual reduction power input: in energy consumption: in energy costs: in emissions: 70 % 39 MWh ≈ 5.000 euro total 23 tonnes CO2 *Assumptions: electricity price 0.13 euros per kWh, continuous operation 24 hours a day, 365 days a year If you look at the figures for the iQ-motor over a prolonged period, its considerable energy-savings potential becomes especially obvious. 350 Electricity price: 0.13 euro per kWh 300 Consumption [MWh] Number of motors: 200 250 Savings potential Continuous operation (24 h/365 d) 200 ≈138 t CO2 Axial blades: 200 mm /28° blade angle 150 ≈30.600 euro CO2 emissions factor: 0.596 kg per kWh 100 (Federal Environment Agency, Dessau, May 2008) iQ 3612 AC-shaded-pole motor (comparable) 50 0 0 1 2 3 4 5 6 Service life [years] iQ motor in energy-saving calculator: How much energy and money could an iQ motor save in your company? By what amount could you decrease CO2 emissions in the process? You can get a good idea of this with the ebmpapst energy savings calculator at www.greentech.info. Go for your energy cost calculation there and the numbers will speak for themselves! 51 iQ/iQ2 3608 Hybrid Standard, ROS, ROD, 2 Speeds Hybrid iQ/iQ2 3612 24 V Standard, ROS, ROD, 2 Speeds Hybrid iQ/iQ2 3620 24 V Perm. amb. temp. Mass Standard, ROS, ROD, 2 Speeds Output power Features Speed/rpm Type Frequency Nominal data Nominal voltage Technical data V Hz rpm W °C kg 220-240 50/60 1300 5 -40..+50 0,5 115* 50/60 1550 5 -40..+50 0,5 220-240 50/60 1300 5 -40..+50 0,4 115* 50/60 1550 5 -40..+50 0,4 220-240 50/60 1300 15 -40..+50 0,6 115* 50/60 1550 15 -40..+50 0,6 220-240 50/60 1300 15 -40..+50 0,5 115* 50/60 1550 15 -40..+50 0,5 24 -- 24 -- 1300 400-1300 11 -40..+50 0,6 11 -40..+50 0,6 220-240 50/60 1300 20 -40..+50 0,8 115* 50/60 1550 20 -40..+50 0,8 220-240 50/60 1300 20 -40..+50 0,7 115* 50/60 1550 20 -40..+50 0,7 24 -- 15,5 -40..+50 0,8 24 -- 15,5 -40..+50 0,8 1300 400-1300 Dimensions a b 74 43,5 30,5 82 43,5 30,5 90 51,5 38,5 *With 2 Speeds: upper speed subject to alterations A-side 83 67 Ø41 a c 15 4x) ( M4 11,5 480 / 1000 / 1500 51 Ø3,6 Ø25,4 Standard version M4 26 b B-side Standard direction of rotation 52 A-side c Multi function version (only iQ 3612) A-side B-side 82 83 67 Ø41 18 48,9 M4 (3x) 30,5 Depth of screw max. 5 mm M4 51 48 Ø3,6 Ø25,4 3x 12 0° 13 15 1500 11,5 ) (4x 4 M 26 Ø41 Ø71,4 M4 B-side A-side 43,4 Standard direction of rotation 24 V version; 400 - 1300 rpm; 0-10 V interface Speed vs. control voltage: 1200 1000 Speed [rpm] 800 600 400 200 0 0 1 2 3 4 5 6 7 8 9 Control voltage [V] 53 Axial impeller p. 58 Mounting bracket p. 59 Guard grille p. 60 Basket guard grille p. 60 Wall ring p. 61 iQ/iQ2-motor – combination with axial impellers Axial impeller blade angle Input power running at full throttle Input power running at free air Air flow running at free air at n=1300 rpm iQ/iQ2 3608 mm ° W W m3/h 154 22 3,0 2,0 170 154 28 3,8 2,8 190 154 34 4,1 3,3 220 172 22 4,6 2,6 230 172 28 6,1 3,8 270 172 34 7,8 5,0 310 200 22 9,2 4,5 360 Curves Motor Axial impeller diameter Power input and air flow A B C iQ/iQ2 3612 200 28 9,2 5,5 410 mm ° W W m3/h 172 28 4,2 2,9 270 172 34 5,7 3,8 310 200 22 5,1 3,4 360 200 28 8,3 5,3 410 200 34 12,1 7,3 470 230 22 9,6 6,0 520 230 28 19,0 13,1 710 230 34 20,5 16,9 750 254 22 21,2 11,3 710 19,3 21,2 980 W W m3/h 16,1 8,3 520 21,2 11,9 710 25,0 13,9 750 26,5 12,3 710 27,4 23,1 980 25,7 28,4 1010 23,7 24,3 1380 B iQ/iQ2 3620 subject to alterations 254 * 28 mm ° 230 22 230 28 230 34 254 22 254 28 254 * 34 300 * 22 D E F E G H * Depending on back pressure, full nominal speed of 1300 min-1 is not reached to some part. Depending on mounting situation and version, a speed of approx. 1200 min-1 (+/- 100 min-1) is reached. Due to the intelligent electronics, however, safe (permanent) operation is still guaranteed. Power ratings (220 - 240 V design): Power input and air flow at 230 V / 50 Hz and a constant speed of 1300 min-1. 54 Axial impeller p. 58 Mounting bracket p. 59 Guard grille p. 60 Basket guard grille p. 60 Wall ring p. 61 55 iQ/iQ2-motor Air performance curves measured in wall ring, at a constant speed of 1,300 rpm. A Pa iQ/iQ2 3608 / 3612, Ø 172 Pa iQ/iQ2 3608, Ø 154 B 90 50 80 70 40 60 50 30 40 20 30 20 10 pfs pfs 10 50 22° 100 28° 150 200 250 qV m3/h 34° 50 100 22° 200 250 300 m3/h 34° iQ/iQ2 3612, Ø 200 Pa iQ/iQ2 3608, Ø 200 150 28° C Pa qV D 70 50 60 50 40 40 30 30 20 20 10 pfs pfs 10 qV 50 22° 56 100 28° 150 200 250 300 350 m3/h qV 100 22° 200 28° 300 34° 400 m3/h E Pa iQ/iQ2 3612, Ø 254 Pa iQ/iQ2 3612 / 3620, Ø 230 F 100 80 70 80 60 50 60 40 40 30 20 20 pfs pfs 10 100 200 22° 28° 300 400 500 600 700 qV m3/h 200 22° 34° 600 800 m3/h iQ/iQ2 3620, Ø 300 Pa iQ/iQ2 3620, Ø 254 400 28° G Pa qV 100 80 80 60 60 40 40 20 20 pfs pfs 100 H qV 200 22° 400 28° 34° 600 800 m3/h qV 200 400 600 800 1000 1200 m3/h 22° 57 Axial impellers b b ❮ "V" "A" ❯ – Material: Sheet aluminium a c 6,6 ❮ Direction of rotation c 4 x Ø 4.0 with pitch circle for holes Ø 25.4 mm Axial impellers Part no. for dir. of air flow "V" Part no. for dir. of air flow "A" Blade angle α 27453.34001 27453.34201 27453.34002 27453.34202 27453.34003 a b c 22° ± 1°30’ 154,0 27,5 14,0 28° ± 1°30’ 154,0 32,0 16,0 27453.34203 34° ± 1°30’ 154,0 37,0 18,0 27453.34004 27453.34204 22° ± 1°30’ 172,0 31,0 14,5 27453.34005 27453.34205 28° ± 1°30’ 172,0 36,0 17,0 27453.34006 27453.34206 34° ± 1°30’ 172,0 42,0 21,0 27453.34007 27453.34207 22° ± 1°30’ 200,0 32,0 15,5 27453.34008 27453.34208 28° ± 1°30’ 200,0 37,5 18,0 27453.34009 27453.34209 34° ± 1°30’ 200,0 45,0 22,0 27453.34010 27453.34210 22° ± 1°30’ 230,0 35,0 17,5 27453.34011 27453.34211 28° ± 1°30’ 230,0 43,0 21,5 27453.34012 27453.34212 34° ± 1°30’ 230,0 50,0 24,0 27453.34013 27453.34213 22° ± 1°30’ 254,0 37,0 19,0 27453.34014 27453.34214 28° ± 1°30’ 254,0 45,0 23,5 27453.34015 27453.34215 34° ± 1°30’ 254,0 52,0 26,0 27453.34016 27453.34216 22° ± 1°30’ 300,0 43,0 21,5 27453.34017 27453.34217 28° ± 1°30’ 300,0 53,5 26,5 27453.34018 27453.34218 34° ± 1°30’ 300,0 61,0 30,0 subject to alterations 58 Mounting bracket b b 2,5 18 18 26 18 18 40 16 25 25 4,3 14 8 4,3 14 4,2 24 c d 8,2 c d – Material: Sheet steel, galvanized and blue chromated 10 9° 6,2 2,5 8,2 Vers. 3 a Vers. 2 a Vers. 1 5 16,2 Mounting bracket - foot measure 18 mm (multi-function design) Part no. Size Vers. a b c d 27452.71002 172 1 56,0 51,0 78,0 100,0 27452.71005 200 1 67,0 51,0 78,0 100,0 27452.71003 230 1 74,5 51,0 78,0 100,0 27452.71004 254 2 85,5 27452.71001 300 3 112,0 51,0 — 78,0 100,0 150,0 172,0 subject to alterations 51 51 51 1,5 4,3 13 31,8 50,3 8,2 8 21 40 8,2 26 24 8,2 78 100 26 7 78 100 26 14 2,5 2,5 2,5 78 100 – Material: Sheet steel, galvanized and blue chromated a Vers. 3 a Vers. 2 a Vers. 1 4,3 14 14 4,3 Mounting bracket - foot measure 26 mm (standard design or multi-function design) Part no. Size Vers. a 27452.71201 154 1 39,0 27452.71202 172 1 52,0 200 1 72,0 230 1 72,0 27452.71204 254 1 84,0 27452.71205 254 2 84,0 27452.71206 300 2 109,0 27452.71207 300 3 109,0 27452.71203 subject to alterations 59 Guard grille – Material: Steel, galvanized and blue chromated b Øa 94,5 2,7 c 5 Guard grille Part no. Size Max. blade angle α at "V" Max. blade angle α at "A" 27452.70002 154 34° 27452.70003 172 34° 27452.70004 200 27452.70005 27452.70006 27452.70007 a b c 34° 170,0 190,0 11,5 34° 188,0 208,0 11,5 34° 28° 214,0 236,0 11,5 230 28° 28° 246,0 266,0 17,5 254 28° 28° 270,0 290,0 17,5 300 — 22° 324,0 344,0 17,5 subject to alterations 2,7 – Material: Steel, galvanized and blue chromated Øa Øb 94,5 c 92 5 Basket guard grille Part no. Size Max. blade angle α at "V" Max. blade angle α at "A" 27452.70201 172 34° 27452.70202 200 34° 27452.70203 230 27452.70204 254 27452.70205 300 subject to alterations 60 a b c 34° 188,0 208,0 37,5 28° 212,0 236,0 37,5 28° 28° 246,0 266,0 40,0 28° 28° 270,0 290,0 40,0 — 22° 324,0 344,0 46,8 Wall rings d Øa 67 67 – Material: Sheet steel, coated in grey plastic ❮ "V" R3 ,5 b 4,3 2 4,3 1 48 c Wall rings, direction of air flow "V" Part no. (sheet steel) Part no. (plastic) Size Max. blade angle α 27452.70501 27452.70802 154 27452.70502 27452.70803 172 27452.70503 27452.70804 27452.70504 27452.70505 27452.70506 27452.70806 a b c d d (plastic) 34° 164,0 190,0 200,0 24,0 26,0 34° 182,0 208,0 223,0 24,0 26,0 200 34° 210,0 236,0 246,0 24,0 26,0 --- 230 28° 240,0 266,0 276,0 24,0 --- 27452.70805 254 28° 264,0 290,0 300,0 24,0 26,0 300 22° 308,0 344,0 356,0 24,0 26,0 subject to alterations 36 – Material: Sheet steel, coated in grey plastic ,5 R4 67 67 1 d b 2 "A" ❯ Øa 4,3 4,3 c Wall rings, direction of air flow "A" Part no. (sheet steel) Part no. (plastic) Size Max. blade angle α a b c d d (plastic) 27452.70701 --- 154 34° 162,0 190,0 200,0 24,0 --- 27452.70702 --- 172 34° 180,0 208,0 223,0 24,0 --- 27452.70703 --- 200 28° 208,0 236,0 246,0 24,0 --- 27452.70704 --- 230 28° 238,0 266,0 276,0 24,0 --- 27452.70705 27452.70807 254 28° 262,0 290,0 300,0 24,0 26,0 27452.70706 --- 300 22° 308,0 344,0 356,0 24,0 --- subject to alterations 61 Technical parameters & scope High standards for all ebm-papst products Here at ebm-papst, we constantly strive to further improve our products in order to be able to offer you the best possible product for your application. Careful monitoring of the market ensures that technical innovations are reflected in the improvements of our products. Based on the technical parameters listed below and the ambience you want our product to operate in, we here at ebm-papst can always work out the best solution for your specific application. General performance parameters Service life Any deviations from the technical data and parameters described here The service life of ebm-papst products depends on two major factors: are listed on the product-specific data sheet. – The service life of the insulation system Type of protection The service life of the insulation system mainly depends on voltage level, The type of protection is specified in the product-specific data sheets. temperature and ambient conditions, such as humidity and condensation. – The service life of the bearing system The service life of the bearing system depends mainly on the thermal load Insulation class on the bearing. The insulation class is specified in the product-specific data sheets. The majority of our products use maintenance-free ball bearings for any mounting position possible. As an option, sleeve bearings can be Mounting position used, which is indicated on the product-specific data sheet wherever The mounting position is specified in the product-specific data sheets. applicable. The service life L10 of the ball bearings can be taken as approx. 40,000 Condensate discharge holes operating hours at an ambient temperature of 40 °C, yet this estimate Information on the condensate discharge holes is provided in the can vary according to the actual ambient conditions. product-specific data sheets. We will gladly provide you with a lifetime calculation taking into account your specific operating conditions. Mode of operation The mode of operation is specified in the product-specific data sheets. Motor protection / thermal protection Information on motor protection and thermal protection is provided in the Protection class product-specific data sheets. The protection class is specified in the product-specific data sheets. Depending on motor type and field of application, the following protective features are realised: – Thermal overload protection (TOP), either in-circuit or external – PTC with electronic diagnostics – Impedance protection – Thermal overload protection (TOP) with electronic diagnostics – Current limitation via electronics If an external TOP is connected, the customer has to make sure to connect a conventional trigger device for switching it off. Products without fitted TOP and without protection against improper use, a motor protection complying with the valid standards has to be installed. 62 Left: Endurance test room Middle: Shock test Right: Chamber test rig Mechanical strain / performance parameters Legal and normative directives All ebm-papst products are subjected to comprehensive tests complying The products described in this catalogue are designed, developed and with the normative specifications. In addition to this, the tests also reflect produced in keeping with the standards in place for the relevant product the vast experience and expertise of ebm-papst. and, if known, the conditions governing the relevant fields of application. Vibration test Standards Vibration tests are carried out in compliance with Information on standards is provided in the product-specific data sheets. – Vibration test in operation according to DIN IEC 68, parts 2-6 – Vibration test at standstill according to DIN IEC 68, parts 2-6 EMC Information on EMC standards is provided in the product-specific data Shock load sheets. Shock load tests are carried out in compliance with Complying with the EMC standards has to be established on the final – Shock load according to DIN IEC 68, parts 2-27 appliance, as different mounting situations can result in changed EMC properties. Balancing quality Testing the balancing quality is carried out in compliance with Leakage current – Residual imbalance according to DIN ISO 1940 Information on the leakage current is provided in the product-specific – Standard balancing quality level G 6.3 data sheets. Should you require a higher balancing quality level for your specific Measuring is according to IEC 60990. application, please let us know and specify this when ordering your product. Approvals In case you require a specific approval for your ebm-papst product Chemo-physical strain / performance parameters (VDE, UL, GOST, CCC, CSA, etc.) please let us know. Should you have questions about chemo-physical strain, please direct Most of our products can be supplied with the relevant approval. them to your ebm-papst contact. Information on existing approvals is provided in the product-specific data sheets. Fields of application, industries and applications Our products are used in various industries and applications: Air performance measurements Ventilation, air-conditioning and refrigeration technology, clean room All air performance measurements are carried out on suction side and on technology, automotive and rail technology, medical and laboratory tech- chamber test beds conforming to the specifications as per ISO 5801 and nology, electronics, computer and office technology, telecommunications, DIN 24163. The fans under test are installed in the measuring chamber at household appliances, heating, machines and plants, drive engineering. free air intake and exhaust (installation category A) and are operated at Our products are not designed for use in the aviation and aerospace nominal voltage, with AC also at nominal frequency, and without any industry! additional components such as guard grilles. As required by the standard, the air performance curves correspond to an air density of 1.2 kg/m3. 63 Room for precision noise measuring Measurement conditions for air and noise measurement ebm-papst products are measured under the following conditions: – Axial and diagonal fans in direction of rotation “V” in full nozzle and without guard grille – Backward curved centrifugal fans, free-running and with inlet nozzle – Forward curved single and dual inlet centrifugal fans with housing Noise measurements All noise measurements are carried out in low-reflective test rooms with reverberant floor. Thus the ebm-papst acoustic test chambers meet the requirements of precision class 1 according to DIN EN ISO 3745. For noise measurement, the fans being tested are placed in a reverberant wall and operated at nominal voltage (for AC, also at nominal frequency) without additional attachments such as the guard grille. Sound pressure level and sound level All acoustic values are established according to ISO 13347, DIN 45635 and ISO 3744/3745 to accuracy class 2 and given in A-rated form. When the sound pressure level (Lp) is measured, the microphone is on the intake side of the fan being tested, usually at a distance of 1 m on the fan axis. To measure the sound power level (Lw), 10 microphones are distributed over an enveloping surface on the intake side of the fan being tested (see graphic). The sound power level measured can be roughly calculated 1,5d from the sound pressure level by adding 7 dB. D Measuring configuration as per ISO 13347-3 respectively DIN 45635-38: 10 measuring points d≥D h = 1,5d ... 4,5d h 3d Measurement area S = 6d2 + 7d (h + 1,5d) 2d 64 pressure level of a fan is approximately 75 dB(A). The level increase measured from the diagram is 9 dB. Thus the overall sound level of the installation can be expected to be 84 dB(A). 15 10 9 Example: 8 A3G800 axial fans are on a condenser. According to the data sheet, the sound 5 the noise values specified in the data sheet. This is shown in the diagram opposite. 0 The noise characteristics of multiple identical fans can be determined in advance based on [dB] [dB(A)] Adding 2 noise sources with the same level results in a level increase of approx. 3 dB. Increase in sound pressure / sound power level Combined level of multiple same-level sound sources 1 2 3 4 5 6 7 8 9 10 15 20 25 ating point and an axial fan A3G710 with 71 dB(A) in a ventilation unit. The level difference is 4 dB. The level increase can now be read in the diagram as approx. 1.5 dB. This means that the overall sound level of the unit can be expected to be 76.5 dB(A). 3 2 1,5 Example: There is an axial fan A3G800 with a sound pressure level of 75 dB(A) at the oper- 1 levels given in the data sheet. This is shown in the diagram opposite. 0 The acoustic performance of two different fans can be predetermined based on the sound Increase in sound pressure / sound power level Combined level of two different-level sound sources [dB] [dB(A)] Number of sources of sound with identical level 0 4 8 12 16 20 Sound power level is independent of distance to the sound source. In contrast to this, sound -10 pressure level decreases the further away the noise source is. The adjacent diagram shows 0 [dB] [dB(A)] Distance laws 24 [dB] [dB(A)] Difference in level with two sources of sound the decrease in level under far sound field conditions. Far sound field conditions apply when- decreases by 6 dB. In the near field of the fan, other correlations apply and the decrease in levels can be considerably smaller. The following example only applies to far sound field conditions and can vary strongly depending on the installation effects: With an axial fan A3G300, a sound pressure level of 65 dB(A) was measured at a distance of 1 m. According to the adjacent diagram, at a distance of 20 m we would get a reduction by -20 -26 -30 vant literature on this complex topic. Per doubling of distance, the level in the far sound field -40 wavelength to be considered. For more information on far sound field, please consult the rele- Decrease in sound pressure level ever the distance between microphone and fan is big when compared to fan diameter and 1 Distance 2 5 10 20 50 100 [m] 26 dB, i.e. a sound pressure level of 39 dB(A). 65 fan agent compact fan agent ebm-papst in Germany motor specialist motor agent Germany ebm-papst Mulfingen GmbH & Co. KG ebm-papst St. Georgen GmbH & Co. KG ebm-papst Landshut GmbH Bachmühle 2 D-74673 Mulfingen Phone +49 7938 81-0 Fax +49 7938 81-110 [email protected] Hermann-Papst-Straße 1 D-78112 St. Georgen Phone +49 7724 81-0 Fax +49 7724 81-1309 [email protected] Hofmark-Aich-Straße 25 D-84030 Landshut Phone +49 871 707-0 Fax +49 871 707-465 [email protected] www.ebmpapst.com www.ebmpapst.com www.ebmpapst.com 66 Berlin Dipl.-Ing. (TH) Jens Duchow Händelstraße 7 D-16341 Panketal Phone +49 30 944149-62 Fax +49 30 944149-63 [email protected] Heilbronn / Heidelberg Dipl.-Ing. Mark Gartner Gehrweg 12 D-74199 Unterheinriet Phone +49 7130 404569-1 Fax +49 7130 404569-2 [email protected] Bielefeld Dipl.-Ing. (FH) Wolf-Jürgen Weber Niehausweg 13 D-33739 Bielefeld Phone +49 5206 91732-31 Fax +49 5206 91732-35 [email protected] Kassel Dipl.-Ing. (FH) Ralph Brück Hoherainstraße 3 b D-35075 Gladenbach Phone +49 6462 4071-10 Fax +49 6462 4071-11 [email protected] Dortmund Dipl.-Ing. (FH) Hans-Joachim Pundt Auf den Steinern 3 D-59519 Möhnesee-Völlinghausen Phone +49 2925 800-407 Fax +49 2925 800-408 [email protected] Koblenz Winfried Schaefer Hinter der Kirch 10 D-56767 Uersfeld Phone +49 2657 16-96 Fax +49 2657 16-76 [email protected] Frankfurt Dipl.-Ing. Christian Kleffmann Dr.-Hermann-Krause-Straße 23 D-63452 Hanau Phone +49 6181 1898-12 Fax +49 6181 1898-13 [email protected] Munich Dipl.-Wirt.-Ing. (FH) Jens Peter Landsbergerstraße 14 D-86932 Pürgen Phone +49 8196 99877-54 Fax +49 8196 99877-55 [email protected] Halle Dipl.-Ing. (TU) Michael Hanning Lercheneck 4 D-06198 Salzatal / OT Lieskau Phone +49 345 55124-56 Fax +49 345 55124-57 [email protected] Nuremberg Dipl.-Wirt.-Ing. (FH) Axel Resch Dr.-August-Koch-Str. 1 D-91639 Wolframs-Eschenbach Phone +49 9875 9783-170 Fax +49 9875 9783-171 [email protected] Hamburg Ingenieurbüro Breuell GmbH Ing. Dirk Kahl Elektroingenieur Grützmühlenweg 48 D-22339 Hamburg Phone +49 40 538092-19 Fax +49 40 538092-84 [email protected] Offenburg Dipl.-Ing. (FH) Ralf Braun Hubeneck 21 D-77704 Oberkirch Phone +49 7802 9822-52 Fax +49 7802 9822-53 [email protected] Stuttgart Dipl.-Ing. (FH) Rudi Weinmann Hindenburgstraße 100/1 D-73207 Plochingen Phone +49 7153 9289-80 Fax +49 7153 9289-81 [email protected] Ulm M.Sc. Reinhard Sommerreißer Am Silbermannpark 10 D-86161 Augsburg Phone +49 821 6610-7023 Fax +49 821 6610-7024 [email protected] Distributors Frankfurt R.E.D. Handelsgesellschaft mbH Gutenbergstraße 3 D-63110 Rodgau - Jügesheim Phone +49 6106 841-0 Fax +49 6106 841-111 [email protected] www.red-elektromechanik.de Hamburg Breuell + Hilgenfeldt GmbH Grützmühlenweg 48 D-22339 Hamburg Phone +49 40 538092-20 Fax +49 40 538092-84 [email protected] Munich A. Schweiger GmbH Ohmstraße 1 D-82054 Sauerlach Phone +49 8104 897-0 Fax +49 8104 897-90 [email protected] www.schweiger-gmbh.com (1 to 5 pieces) North Breuell + Hilgenfeldt GmbH Grützmühlenweg 48 D-22339 Hamburg Phone +49 40 538092-20 Fax +49 40 538092-84 [email protected] South HDS Ventilatoren Vertriebs GmbH Glaswiesenstraße 1 D-74677 Dörzbach Phone +49 7937 80355-20 Fax +49 7937 80355-25 [email protected] www.hds-gmbh.net ebm-papst in Europe Europe Austria ebm-papst Motoren & Ventilatoren GmbH Straubingstraße 17 A-4030 Linz Phone +43 732 321150-0 Fax +43 732 321150-20 [email protected] www.ebmpapst.at Belarus ebm-papst Bel AgmbH P.O. Box 117 BY-220138 Minsk Phone +375 17 3851556 Fax +375 17 3851556 [email protected] www.ebmpapst.by Belgium ebm-papst Benelux B.V. Sales office Belgium-Luxemburg Romeinsestraat 6/0101 Research Park Haasrode B-3001 Heverlee-Leuven Phone +32 16 396-200 Fax +32 16 396-220 [email protected] www.ebmpapst.be Bulgaria ebm-papst Romania S.R.L. Str. Tarnavei No. 20 RO-500327 Brasov Phone +40 268 331859 Fax +40 268 312805 [email protected] Croatia ebm-papst Industries Kft. Ezred u. 2. H-1044 Budapest Phone +36 1 8722-190 Fax +36 1 8722-194 [email protected] Czech Republic / Slovakia ebm-papst CZ s.r.o. Kaštanová 34a CZ-620 00 Brno Phone +420 544 502-411 Fax +420 547 232-622 [email protected] www.ebmpapst.cz Denmark ebm-papst Denmark ApS Vallensbækvej 21 DK-2605 Brøndby Phone +45 43 631111 Fax +45 43 630505 [email protected] www.ebmpapst.dk Estonia ebm-papst Oy, Eesti Filiaal Kesk tee 13 Aaviku küla, Jüri Tehnopark EST-75301 Rae Vald, Harjumaa Phone +372 65569-78 Fax +372 65569-79 www.ebmpapst.ee Finland ebm-papst Oy Puistotie 1 FIN-02760 Espoo Phone +358 9 887022-0 Fax +358 9 887022-13 [email protected] www.ebmpapst.fi France ebm-papst sarl ZI Nord - rue A. Mohler BP 62 F-67212 Obernai Cedex Phone +33 820 326266 Fax +33 3 88673883 [email protected] www.ebmpapst.fr Greece Helcoma Th. Rotas & Co OE Davaki 65 GR-17672 Kallithea-Attiki Phone +30 210 9513-705 Fax +30 210 9513-490 [email protected] www.helcoma.gr Hungary ebm-papst Industries Kft. Ezred u. 2. H-1044 Budapest Phone +36 1 8722-190 Fax +36 1 8722-194 [email protected] Iceland RJ Engineers Stangarhyl 1a IS-110 Reykjavik Phone +354 567 8030 Fax +354 567 8015 [email protected] www.rj.is Ireland ebm-papst UK Ltd. Chelmsford Business Park GB-Chelmsford Essex CM2 5EZ Phone +44 1245 468555 Fax +44 1245 466336 [email protected] www.ebmpapst.co.uk AuBren Limited Portlaoise Business & Technology Park Mountrath Road IRL-Portlaoise, Co. Laois Phone +353 57 8664343 Fax +353 57 8664346 [email protected] www.aubren.com Italy ebm-papst Srl Via Cornaggia 108 I-22076 Mozzate (Co) Phone +39 0331 836201 Fax +39 0331 821510 [email protected] www.ebmpapst.it Macedonia ebm-papst Industries Kft. Ezred u. 2. H-1044 Budapest Phone +36 1 8722-190 Fax +36 1 8722-194 [email protected] 67 fan agent compact fan agent ebm-papst in Europe motor specialist motor agent Netherlands ebm-papst Benelux B.V. Engelseweg 127 NL-5705 AC Helmond Phone +31 492 502-900 Fax +31 492 502-950 [email protected] www.ebmpapst.nl Russia ebm-papst Ural GmbH Posadskaja-Strasse, 23(E), 3 RU-620102 Ekaterinburg Phone +7 343 2338000 Fax +7 343 2337788 [email protected] www.ebmpapst.ur.ru Switzerland ebm-papst AG Rütisbergstrasse 1 CH-8156 Oberhasli Phone +41 44 73220-70 Fax +41 44 73220-77 [email protected] www.ebmpapst.ch Norway ebm-papst AS P.B. 173 Holmlia N-1203 Oslo Phone +47 22 763340 Fax +47 22 619173 [email protected] www.ebmpapst.no ebm-papst Rus GmbH proezd 4529, vladenie 5, stroenie 1 RU-141000 Mytistschi, Oblast Moskau Phone +7 495 9807524 Fax +7 495 5140924 [email protected] www.ebmpapst.ru Turkey Akantel Elektronik San. Tic. LTD. Sti. Atatürk Organize Sanayi Bölgesi 10007 SK. No.:6 TR-35620 Cigli-Izmir Phone +90 232 3282090 Fax +90 232 3280270 [email protected] www.ebmpapst.com.tr Poland ebm-papst Polska Sp. z o.o. ul. Annopol 4A PL-03236 Warszawa Phone +48 22 6757819 Fax +48 22 6769587 [email protected] www.ebmpapst.pl Portugal ebm-papst (Portugal), Lda. Centro Empresarial de Alverca Rua de Adarse, Vale D’Ervas Corpo D / Fracção 3 P-2615-178 Alverca do Ribatejo Phone +351 218 394 880 Fax +351 218 394 759 [email protected] www.ebmpapst.pt Romania ebm-papst Romania S.R.L. Str. Tarnavei Nr. 20 RO-500327 Brasov Phone +40 268 331859 Fax +40 268 312805 [email protected] 68 Serbia & Montenegro ebm-papst Industries Kft. Ezred u. 2. H-1044 Budapest Phone +36 1 8722-190 Fax +36 1 8722-194 [email protected] Spain ebm-papst Ibérica S.L. Avda. del Sistema Solar, 29 E-28830 San Fernando de Henares (Madrid) Phone +34 91 6780894 Fax +34 91 6781530 [email protected] www.ebmpapst.es Sweden ebm-papst AB Äggelundavägen 2 S-17562 Järfälla Phone +46 10 4544400 Fax +46 8 362306 [email protected] www.ebmpapst.se Ukraine ebm-papst Ukraine LLC Lepse Boulevard, 4, Building 21 UA-03067 Kiev Phone +38 044 2063091 Fax +38 044 2063091 [email protected] www.ebmpapst.ua United Kingdom ebm-papst UK Ltd. Chelmsford Business Park GB-Chelmsford Essex CM2 5EZ Phone +44 1245 468555 Fax +44 1245 466336 [email protected] www.ebmpapst.co.uk ebm-papst Automotive & Drives (UK) Ltd. The Smithy Fidlers Lane GB-East Ilsley, Berkshire RG20 7LG Phone +44 1635 2811-11 Fax +44 1635 2811-61 A&[email protected] www.ebmpapst-ad.com ebm-papst in America and Africa America Argentina ebm-papst de Argentina S.A. Hernandarias 148 Lomas del Mirador Pcia. de Buenos Aires (1752) Phone +54 11 46576135 Fax +54 11 46572092 [email protected] www.ebmpapst.com.ar Brazil ebm-papst Motores Ventiladores Ltda. Av. José Giorgi, 301 Galpões B6+B7 Condominio Logical Center BR-06707-100 Cotia - São Paulo Phone +55 11 4613-8700 Fax +55 11 4777-1456 [email protected] www.ebmpapst.com.br USA ebm-papst Inc. P.O. Box 4009 100 Hyde Road USA-Farmington, CT 06034 Phone +1 860 674-1515 Fax +1 860 674-8536 [email protected] www.ebmpapst.us ebm-papst Automotive & Drives, Inc. 3200 Greenfield, Suite 255 USA-Dearborn, MI 48120 Phone +1 313 406-8080 Fax +1 313 406-8081 [email protected] www.ebmpapst-automotive.us Africa South Africa ebm-papst South Africa (Pty) Ltd. P.O. Box 3124 1119 Yacht Avenue ZA-2040 Honeydew Phone +27 11 794-3434 Fax +27 11 794-5020 [email protected] www.ebmpapst.co.za Canada ebm-papst Canada Inc. 1800 Ironstone Manor, Unit 2 CDN-Pickering, Ontario, L1W3J9 Phone +1 905 420-3533 Fax +1 905 420-3772 [email protected] www.ebmpapst.ca Mexico ebm Industrial S. de R.L. de C.V. Paseo de Tamarindos 400-A-5to Piso Col. Bosques de las Lomas MEX-Mexico 05120, D.F. Phone +52 55 3300-5144 Fax +52 55 3300-5243 [email protected] www.ebmpapst.com.mx 69 fan agent compact fan agent ebm-papst in Asia and Australia motor specialist motor agent Asia China ebm-papst Ventilator (Shanghai) Co., Ltd. No. 418, Huajing Road WaiGaoQiao Free Trade Zone No. 2001, Yang Gao (N) Road VRC-200131 Shanghai, P.R. of China Phone +86 21 5046-0183 Fax +86 21 5046-1119 [email protected] www.ebmpapst.com.cn Hong Kong ebm-papst Hong Kong Ltd. Unit No. 13,9 / F Technology Park, 18 On Lai Street Siu Lek Yuen, Shatin N.T. Hong Kong - P.R. of China Phone +852 2145-8678 Fax +852 2145-7678 [email protected] India ebm-papst India Pvt. Ltd. 26/3, G.N.T. Road, Erukkencherry IND-Chennai-600118 Phone +91 44 25372556 Fax +91 44 25371149 [email protected] www.ebmpapst.in Indonesia ebm-papst Indonesia Representative Office German Centre, 4th Floor, Suite 4470 Jl. Kapt. Subijono Dj. Bumi Serpong Damai RI-15321 Tangerang Phone +62 21 5376250 Fax +62 21 5388305 [email protected] Israel Polak Bros. Import Agencies Ltd. 9 Hamefalsim Street IL-Kiryat Arie, Petach-Tikva 49514 Phone +972 3 9100300 Fax +972 3 5796679 [email protected] www.polak.co.il 70 Japan ebm-papst Industries Japan K.K. 12th Floor, Benex S-3 Bldg. 3-20-8 Shinyokohama, Kohoku-ku J-222-0033 Yokohama Phone +81 45 47057-51 Fax +81 45 47057-52 [email protected] www.ebmpapst.jp Thailand ebm-papst Thailand Co., Ltd. 99/9 Moo 2, Central Chaengwattana Tower 14th Floor, Room 1402 Chaengwattana Road Bangtarad, Pakkret THA-11120 Nonthaburi Phone +66 2 8353785-7 Fax +66 2 8353788 [email protected] Korea ebm-papst Korea Co. Ltd. 6F, Trutec Bldg. B 6-2, Digital Media City (DMC) Sangam-Dong, Mapo-Gu ROK-Seoul 121-270 Phone +82 2 366213-24 Fax +82 2 366213-26 [email protected] www.ebmpapst.co.kr United Arab Emirates ebm-papst Middle East FZE PO Box 17755 Jebel Ali Free Zone / FZS1 / AP05 UAE-Dubai Phone +971 4 88608-26 Fax +971 4 88608-27 [email protected] www.ebmpapst.ae Malaysia ebm-papst Malaysia Representative Office Unit 12-2, Jalan USJ Sentral 3 Persiaran Subang, Selangor Darul Ehsan MAL-47600 Subang Jaya Phone +60 3 8024-1680 Fax +60 3 8024-8718 [email protected] Singapore ebm-papst SEA Pte. Ltd. No. 23 Ubi Road 4 #06-00 Olympia Industrial Building SGP-Singapore 408620 Phone +65 65513789 Fax +65 68428439 [email protected] Taiwan ETECO Engineering & Trading Corp. 10F-I, No. 92, Teh-Wei Str. RC-Tsow-Inn District, Kaohsiung Phone +886 7 557-4268 Fax +886 7 557-2788 [email protected] www.ebmpapst.com.tw Vietnam ebm-papst Vietnam Representative Office Room #102, 25 Nguyen Van Thu Street District 1 VN-Ho Chi Minh City Phone +84 8 39104099 Fax +84 8 39103970 [email protected] Australia Australia ebm-papst A&NZ Pty Ltd. 10 Oxford Road AUS-Laverton North, Victoria, 3026 Phone +61 3 9360-6400 Fax +61 3 9360-6464 [email protected] www.ebmpapst.com.au New Zealand ebm-papst A&NZ Pty Ltd. 102 Henderson Valley Road NZ-Henderson, Auckland 1230 Phone +64 9 837-1884 Fax +64 9 837-1899 [email protected] www.ebmpapst.com.au 71 37804-7-8811 · 2012-10 · KD-3’ Printed in Germany ebm-papst ebm-papst ebm-papst Mulfingen GmbH & Co. KG St. Georgen GmbH & Co. KG Landshut GmbH Bachmühle 2 Hermann-Papst-Straße 1 Hofmark-Aich-Straße 25 D-74673 Mulfingen D-78112 St. Georgen D-84030 Landshut Phone +49 7938 81-0 Phone +49 7724 81-0 Phone +49 871 707-0 Fax +49 7938 81-110 Fax +49 7724 81-1309 Fax +49 871 707-465 [email protected] [email protected] [email protected] www.ebmpapst.com