5000 en

DATA LOGGER LR5000 Series
Data Loggers
Complete Line of Easy-to-Use Compact Loggers with Expanded Memory
The new HIOKI compact data logger series easily records temperature, voltage,
current, and instrumentation signals over long periods. Carried over from its
highly reputed predecessor, this series includes features and functions such as
7 times the recording capacity of former models, data import during recording,
continuous measurement even during battery replacement, and intuitive PC software. Flexible and easy-to-use at single and multiple locations, the new HIOKI
compact data logger series is ideal for any application that requires simple set-up
but long-term, reliable recording capabilities.
2
Meet a Wide Variety of Data Logging Applications
Temperature Logger /Humidity Logger
Manage the temperature and humidity in offices and
factories. Visually monitor the data to save on airconditioning and heating costs.
Instrumentation Logger / Voltage Logger
Record fluid flow such as for water, gas and
oil. Measure flow meter output signals to
monitor flow trends.
Clamp Logger
Manage the current consumption of plant
and building equipment. Visually monitor
power costs to efficiently conduct energyand cost-saving activities.
Use as a Voltage Logger to record pyranometer output for
evaluating insulation.
Use as a Clamp Logger and leakage sensor to record and
monitor leakage trends.
pyranometer
Voltage logger has a Preheat function
Use as a Temperature Logger to record warehouse temperatures for
visually monitoring temperature changes of products and goods.
Use as an Instrumentation Logger to record pressure sensor output
and monitor fluctuations in air or oil pressure.
3
Easy operation in just
steps !
Install a Data Logger, set an interval, and start measuring.
Easy to start recording
Unlimited installation capabilities
STEP
Set up
&Record
Wall-mounted Holder
(sold separately)
Not usable with LR5051
Set your recording interval.
(from one second to 60 minutes)
Download data
using infrared
communication.
STEP
Transfer data
from Data Logger
to PC
!
Kickstand
(included, except
for Model LR5051)
Grab the Data Logger from the worksite and connect to a PC.
Communication Adapter
LR5091
Retrieving the
Data Logger
Transfer data from Data Logger to
PC using a USB connection
Using the Data Collector's internal memory, import data from up to 16 Data
Loggers installed on site.*
Download data
u s i n g i n f r a re d
communication.
Requires optional
Communication
Adapter
Importing to
a Data Collector
or
Data Collector
Magnetic Strap
(sold separately)
Hold the REC button
for two seconds to
start recording.
Front
Back
Data Collector
LR5092-20
Retrieving
the Data Collector
Transfer data from Data Logger to
PC using a USB connection
*
Data for up to 16 channels can be stored. Combine up to 16 single-channel Data Loggers (Models LR5011, LR5031,
LR5041, LR5042, and LR5043), or up to eight 2-channel Data Loggers (Models LR5001, and LR5051).
Using an optional SD Memory Card, the amount of data that can be imported
is practically limitless.
Top surface of LR5092-20
SD Card slot
or
USB Connector
Importing to an
SD Memory Card
Transfer data from SD Memory Card
within Data Collector to PC using USB
View data graphically and easily print using the bundled software.
STEP
View graphs
and manage
data
Transfer data directly
from SD Memory Card
4
Advanced Features and Functions
Install Almost Anywhere
Recording capacity up to 7 times previous models
Easily mount the light-weight, pocket-sized loggers in tight
spaces.
Large internal memory stores 60,000 data points per
channel. Long-term recording capability exceeds that of
previous models.
Interval
times
1s
2s
5s
10s
15s
20s
30s
1m
2m
5m
10m
15m
20m
30m
60m
Actual size
Easy-to-see dual display
Instantaneous value
Statistical value
16h
9h
11h
22h
10h
21h
20h
16h
8h
8h
16h
8h
20h
17h
14h
11h
5h
10h
20h
2h
4h
6h
8h
12h
1d
3d
6d
10d
13d
20d
41d
83d
208d
416d
625d
833d
1250d
2500d
40m
20m
20m
40m
20m
8h
1d
2d
3d
5d
10d
20d
52d
104d
156d
208d
312d
625d
20m
50m
40m
30m
20m
The maximum recording time depends on battery
life. The battery may need to be replaced during
long-term recording.
Temperature and humidity or current channels can be
displayed. View maximum and minimum values while
measuring.
Moist environments
Record without missing fluctuations
IP54 splash-proof rating withstands
operation in extremely humid
environments like kitchens and pipe
rooms. (Except Model LR5051)
With usual (instantaneous value) recording at long intervals,
detailed fluctuations occurring within the intervals are
missed. However, with the statistical value recording
mode, detailed fluctuations are captured even when they
occur during long recording intervals. In STAT mode,
measurement is taken every second, and the maximum,
minimum, average, and instantaneous values within the
specified interval are recorded.
Data interval(2sec to 60min)
Transfer data even during recording
1sec
Continue to record even when transferring data.
Data interval(2sec to 60min)
Maximum
data
Maximum
data
Transfer data
from Data Logger
to PC!
Average
data
Instant
data
In the middle of
Recording ...
Input signal
(Temperature,
Voltage, etc.)
Batteries last up to 2 years
Energy-efficient design provides up to two years of battery
life (For the LR5011 only. Actual battery life depends on
model type and settings).
Average
data
Instant
data
Minimum
data
Minimum
data
Record 4 data
for interval
Time
Record 4 data
for interval
Never worry about a dead battery
The worry-free backup function preserves measurement
data even after the battery dies.
Replace batteries while recording
Never worry about operating errors
Recording continues for about 30 seconds
even with the battery removed.
Worry-free backup preserves recorded data even if a new
measurement is started by mistake.
Note. With the LR5001,
re c o rd i n g i s i n t e r r u p t e d
during battery replacement
if the battery is very
weak. After batteries are
replaced, recording resumes
automatically. Previously
recorded data is not lost
during battery replacement.
!
5
Bundled Software Ensures Smooth and Easy Data Analysis
Import data to a PC and create graphs
Use the LR5000 Utility program to import Data Logger data
to a PC to make graphs and analyze data further. Easily
print results using your PC.
Show specific values using the cursor function
Use the A/B cursors to select any location on a graph and
display its value. The PC software can also calculate maximum,
minimum, and average values between A and B cursors.
Simple file aggregation and management
Transferred data can be combined with data previously
transferred (from the same Data Logger unit) into one file on
the PC.
Past data
New data
Saving 1 file
Display data from former Data Logger models
The PC application also supports data collected from the HIOKI
36XX Series Data Loggers.
Print function
Configurating
Data Logger
Graph display
LR5000 Utility Specifications
•Import/export Data Logger settings (LR5091 or
LR5092-20 required)
•Settings sent to each LR5000 logger are also saved
to the PC.
•Graphically display data for up to 16 channels
•Select colors and display/hide any channel and graph
•Copy graph images to clipboard
•Display statistical data (maximum, minimum and average)
•Scaling function
•Print graphs
•Print statistical data.
•Scaling
•Power calculation
•Energy cost calculation
Data processing •Operating ratio calculation
•Integration
•Dew point temperature
•Calculate between channels
•OS:Windows XP (SP2 or later)
Windows Vista (SP1 or later) / Windows 7
•CPU : 1GHz or more
Operating
•Memory : 512MB or more
environment
•Interface : USB
•Free space in hard disk:30MB or more
6
Communication Adapter and Data Collector Specifications
(Product guaranteed for one year)
Physical
appearance
Model
Communication Adapter LR5091
Features
Data Collector LR5092-20
•Collect recorded data from the Data Logger to internal memory or SD card
•View collected data in a graph
•Transfer data from a Data logger to a PC
•Transfer Data Logger configurations or clock settings from internal
•Transfer Data Logger configurations or clock settings from a PC memory or SD card to the Data Logger
•Transfer data from a Data Logger to a PC
to the Data Logger
•Transfer Data Logger configurations or clock settings from a PC to
the Data Logger
Interface with
Data Logger
Interface with PC
Clock functions
Display
-
Display items
-
Infrared optical communications
Internal memory
capacity of data
Removable
storage media
Operating environment
Power supply
USB2.0, Full Speed, Series Mini B Receptacle
Auto calender, auto leap year
Dot-matrix LCD (128 × 64 dots)
Data Logger configurations (Interval, Start/Stop method, Recording
mode, Scaling, Alarm, Power-saving mode, Clock, Range)
Collected data (Record list , Maximum data, Minimum data, Average, Graph, Value)
60,000 data elements ×16ch (instantaneous value mode)
15,000 data elements ×16ch (statistical value mode)
SD Card (SDHC, Max 32GB)
Save data and configurations
Indoors
DC3V (LR6 (AA) Alkaline battery 1.5V×2) or DC5V (USB bus power)
Maximum rated power 1VA
Approx. 12 hours or 500 times of data collection
-
DC5V (USB bus power) Maximum rated power 0.5VA
-
Battery life
Operating temperature
and humidity
0˚C(32˚F) to 40˚C(104˚F) , 80%rh or less (non-condensating)
Dimensions & Mass
Approx. 83mm(3.27 in)W×61mm(2.40in)H×19mm(0.75in)D
43g(1.5oz)
91mm(3.58in)W×141mm(5.55in)H×31mm(1.22in)D
215g(7.6oz) (excluding batteries)
Accessories
USB cable (1m)×1,
CD (Application software "LR5000 Utility") × 1
Instruction manual ×1, Operation manual×1,
LR6 (AA) Alkaline battery 1.5V×2, USB cable(1m)×1,
CD (Application software "LR5000 Utility") × 1
LR5092-20 Option
SD Memory Card (2GB) Z4001
LR5000 Series Common specifications
(Product and accuracy guaranteed for one year)
Recording
interval
1/ 2/ 5/ 10/ 15/ 20/ 30 seconds
1/ 2/ 5/ 10/ 15/ 20/ 30/ 60 minutes
Display items
Recording
methods
One time recording
Stop recording when the memory capacity is full.
Endless recording
Continue recording even when the memory capacity is full.
(old data is overwritten.)
Recording
start / stop
Instantaneous recording
Instantaneous values are recorded at every
Recording modes recording interval.
Statistical value recording
(instantaneous value
Measure at one second intervals, and record the
mode/statistical
instantaneous, maximum,
value mode)
minimum, and average values within every recording
interval.
Storage capacity
Instantaneous value mode 60,000 data sets per channel
Statistical value mode 15,000 data sets per channel
LR5000 Series common options
Magnetic Strap
Z5004
Wall-mounted Holder
LR9901
Not compatible with Model LR5051
Data backup
Measured value, Interval configration, Date, Time,
Alarm, Remaining battery power, Number of data,
Maximum data, Minimum data
Recording start
Manual start
Timer start
Recording stop
Manual stop
Timer stop
When the memory capacity is full (One time recording)
Data from the last recording session is always backed up.
Back up recorded data and configuration when battery is dead.
Interface
Infrared optical communications with LR5091, LR5092-20
Power supply
During battery replacement, recording and clock operations are
preserved for about 30 seconds. (Recording operation continues if
the battery is replaced within about 30 seconds.)
Note. With the LR5001, recording is interrupted during battery replacement if the
battery is very weak. After batteries are replaced, recording resumes automatically.
Previously recorded data is not lost during battery replacement.
7
Product Specifications
See page 6 for Common specifications
(Product and accuracy guaranteed for one year)
Physical
appearance
*Sensor is sold separately.
Model
Humidity Logger LR5001
Temperature measurement with external temperature sensor. Select the
sensor according to the measurement object
Temperature 1ch and Humidity 1ch
Temperature 1ch
±15%rh
Accuracy
-40.0˚C to 180˚C
*Depends on measurement range of sensor.
(LR5011+Sensor)
180
±5.0˚C
120
±2.0˚C
70
±1.0˚C
35
±0.5˚C
0
±1.0˚C
-40
Temperature : ˚C
Temperature : -40˚C to 85˚C
Humidity : 0% to 100%rh
Temperature
Humidity (LR5001+Sensor)
100
(LR5001 + Sensor)
90
*±10%rh ±10%rh ±8%rh ±10%rh
85
70
±2.0˚C
*±8%rh ±8%rh ±6%rh ±8%rh
70
50
±1.0˚C
*±6%rh ±6%rh ±5%rh ±6%rh
35
*
±0.5˚C
10
0
±1.0˚C
0
-40 0
10
20
30
50 85
-40
Temperature : ˚C
Measurement
items
Measurement
range
Temperature and humidity are recorded simultaneously using
supplied or optional temperature and humidity sensors.
Relative humidity : %rh
Features
Temperature Logger LR5011
Temperature : ˚C
* Values provided for reference only.
Waterproof and
dustproof performance
Operating temperature
and humidity
Dimensions &
Mass
Power supply
IP54 (splash-proof construction)
-20˚C(-4˚F) to 70˚C(158˚F) , 80%rh or less (non-condensating)
Approx. 79mm(3.11in)W×57mm(2.24in)H×28mm(1.10in)D
105g(3.7oz)
LR6 (AA) Alkaline battery 1.5V×1
Kickstand
Humidity sensor LR9504×1, Kickstand
Accessories
LR6 (AA) Alkaline battery 1.5V×1, Instruction manual ×1, Operation manual×1
Case 1 : Approx. 3 months Case 2: Approx. 20 days
Case 1 : Approx. 2 years Case 2: Approx. 2 months
Battery life
Case 1 : 1min. recording interval, power-saving mode, Instantaneous recording, environmental temp.20˚C Case 2 :1sec. recording interval, power-saving mode, Instantaneous recording, environmental temp.20˚C
Analysis of measurement data on a PC requires the optional LR5091 Communication Adapter or LR5092-20 Data Collector. See page 6 for details.
(Reference) When the recording interval is set to 10 minutes, the LR5001 Temperature and Humidity Logger can measure for about one year between battery replacements.
LR5001 Options
Humidity Sensor
■ Humidity Sensor
30mm
1m (LR9501)
5m (LR9502)
10m (LR9503)
40mm
(LR9504)
LR5011 Options
■ Molded plastic type
diameter:6mm
: LR9501 (1m)
LR9502 (5m)
LR9503 (10m)
LR9504 (40mm, bundled accessory)
●Temperature range : -40.0˚C to 85.0˚C
●Humidity range
: 0.0%rh to 100.0%rh
●Response time
: Approximately 300 seconds
(Temperature and humidity; 90% response time)
●Models (length)
(Thickness : 8mm)
13mm
Te m p e r a t u r e S e n s o r
28mm
■ Lug type
Outer diameter:7mm
Inner diameter:3.2mm
1m (LR9601)
5m (LR9602)
10m (LR9603)
1m (LR9611)
5m (LR9612)
10m (LR9613)
45mm (LR9604)
●Models (length)
●Temperature range
●Response time
●Material
: LR9601 (1m)
LR9602 (5m)
LR9603 (10m)
LR9604 (45mm)
: -40˚C to 180˚C
: Approx. 100 seconds (90% response time)
: Cable : Silicon
Sensor head : Silicon
■ Sheathed type
■ Needle type
25mm
180mm
diameter 4mm
●Models(length)
●Temperature range
●Response time
●Material
: LR9611 (1m)
LR9612 (5m)
LR9613 (10m)
●Temperature range : -30˚C to 180˚C
●Response time
: Approx. 45 seconds (90% response time)
●Material: Cable : Silicon Sensor head : Nickel-plated brass
●Models(length)
1m
:
:
:
:
LR9621(1m)
-40˚C to 120˚C
Approx. 90 seconds (90% response time)
Cable : Silicon
Sensor head : SUS304
diameter 1.3mm
●Models(length)
●Temperature range
●Response time
●Material
1m
:
:
:
:
LR9631(1m)
-40˚C to 120˚C
Approx. 20 seconds (90% response time)
Cable : Silicon
Sensor head : SUS304
Product Specifications
(Product and accuracy guaranteed for one year)
See page 6 for Common specifications
Physical
appearance
LR5042(5V)
Model
Instrumentation Logger LR5031
Features
For recording 4-20 mA instrumentation signals, etc.
Measurement items
For Instrumentation / 0 to 20mA DC, 1ch
Measurement
range
DC -30.00 to 30.00mA
Voltage Logger LR5041, LR5042, LR5043
For recording instrumentation signals and measuring analog outputs
from sensors and other devices
DC voltage 1ch
LR5041: -50.00mV to 50.00mV
LR5042: -5.000V to 5.000V
LR5043: -50.00V to 50.00V
±0.5%rdg. ±5dgt. (@23˚C±5˚C)
±0.5%rdg. ±5dgt. (@23˚C±5˚C)
Accuracy
Waterproof and
IP54 (splash-proof construction)
dustproof performance
Operating temperature
-20˚C(-4˚F) to 70˚C(158˚F) , 80%rh or less (non-condensating)
and humidity
Approx. 79mm(3.11in)W×57mm(2.24in)H×28mm(1.10in)D, 105g(3.7oz)
Dimensions & Mass
LR6 (AA) Alkaline battery 1.5V×1
Power supply
Connection Cable LR9801×1, Kickstand
Connection Cable LR9802×1, Kickstand
Accessories
LR6 (AA) Alkaline battery 1.5V×1, Instruction manual ×1, Operation manual×1
Case 1 : Approx. 2 years Case 2: Approx. 2 months
Battery life
Case 1 : 1min. recording interval, power-saving mode, Instantaneous recording, environmental temp.20˚C Case 2 : 1 sec. recording interval, power-saving mode, Instantaneous recording, environmental temp.20˚C
Preheat function (When using preheat function, a separate external
Other
power supply is required.)
Analysis of measurement data on a PC requires the optional LR5091 Communication Adapter or LR5092-20 Data Collector. See page 6 for details.
LR5031 Option
LR5041,LR5042,LR5043 Option
4 wires
2 wires
1m
1m
Connection Cable LR9802 (Bundled accessory)
Connection Cable LR9801(Bundled accessory)
Product Specifications (Product and accuracy guaranteed for one year)
See page 6 for Common specifications
*Sensor is sold separately..
Features
Measurement items
Measurement
range
Cord length : Approx. 3m
Cord length : Approx. 3m
CAT III
II 600V
CAT III
II 600V
Connection cord 9219 is
required (sold separately)
Physical
appearance
Physical
appearance
Model
LR5051 Options
Clamp Logger LR5051
Recording load current of 50Hz/60Hz
Recording leak current
AC Current (2 channels)
When Using 9669
When Using CT6500
When Using 9695-02
When Using 9675
When Using 9657-10
:
1000A range
:
50.00A / 500.0A range
:
5.000A / 50.00A range
: 500.0mA / 5.000A range
: 500.0mA / 5.000A range
±0.5%rdg. ±5dgt. +Clamp sensor accuracy
Accuracy
Waterproof and
Not waterproof
dustproof performance
Operating temperature -0˚C(32˚F) to 50˚C(122˚F) , 80%rh or less (non-condensating)
and humidity
Dimensions & Mass Approx. 79mm(3.11in)W×70mm(2.76in)H×37mm(1.46in)D, 165g(5.8oz)
LR6 (AA) Alkaline battery 1.5V × 2
Power supply
LR6 (AA) Alkaline battery 1.5V × 2
Accessories
Instruction manual ×1, Operation manual×1
Case 1 : Approx. 1 years Case 2: Approx. 1 months
Case 1 : 1min. recording interval, power-saving mode, Instantaneous
Battery life
recording, environmental temp.20˚C Case 2 : 1 sec. recording interval,
power-saving mode, Instantaneous recording, environmental temp.20˚C
Analysis of measurement data on a PC requires the optional LR5091
Communication Adapter or LR5092-20 Data Collector. See page 6 for details.
Model
Measurable
conductor diameter
Primary current rating
Accuracy (45Hz to 66Hz)
Maximum rated voltage to earth
Maximum allowable input (45 to 66 Hz)
Dimensions &
Mass
CAT III 300V
Clamp on Sensor 9669 Clamp on Sensor CT6500 Clamp on Sensor 9695-02
φ55 mm (2.17") or less, φ46 mm (1.81") φ15 mm (0.59") or
or less
less
80 (3.15") × 20 (0.79") mm busbar
1000A AC
500A AC
50A AC
±1.0%rdg. ±0.01%f.s. ±1.5%rdg. ±0.03%f.s.
±0.3%rdg. ±0.02%f.s.
600Vrms (insulated conductor) 600Vrms (insulated conductor)
300Vrms (insulated conductor)
1000A continuous 600A continuous
60A continuous
99.5 (3.92")W × 188 (7.40")H × 77 (3.03")W × 151 (5.94")H × 51 (2.01")W × 58 (2.28")H ×
42 (1.65")D mm, 590g (20.8 oz.) 42 (1.65")D mm, 360g (12.7 oz.) 19 (0.75")D mm, 50g (1.8 oz.)
length
: 3m(9.84ft)
Connection Cord 9219(For 9695-02 connection)
Cord length : Approx. 3m
Cord length : Approx. 3m
Physical
appearance
CAT III 300V
CAT III 300V
Clamp on Leak Sensor 9675 Clamp on Leak Sensor 9657-10
Model
φ30mm
φ40mm
Measurable conductor diameter
10A AC
10A AC
Primary current rating
±1.0%rdg.±0.005%f.s.
±1.0%rdg.±0.05%f.s.
Accuracy (45Hz to 66Hz)
Lag current
1mA(When 10A AC is input)
Maximum rated voltage to earth 300Vrms (insulated conductor)
10A continuous
Maximum allowable input (45 to 66 Hz)
60 (2.36")W × 113 (4.45")H ×
Dimensions &
Mass
24 (0.94")D mm, 160g (5.6 oz.)
5mA(When 100A AC is input)
300Vrms (insulated conductor)
30A continuous
74 (2.91")W × 145 (5.71")H ×
42 (1.65")D mm, 380g (13.4 oz.)
Note: Company names and Product names appearing in this catalog are trademarks or registered trademarks of various companies.
HIOKI (Shanghai) Sales & Trading Co., Ltd. :
HEAD OFFICE :
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL +81-268-28-0562 / FAX +81-268-28-0568
http://www.hioki.co.jp / E-mail: [email protected]
HIOKI USA CORPORATION :
6 Corporate Drive, Cranbury, NJ 08512 USA
TEL +1-609-409-9109 / FAX +1-609-409-9108
http://www.hiokiusa.com / E-mail: [email protected]
1608-1610 Shanghai Times Square Office, 93 Huai Hai Zhong Road,
Shanghai, P.R.China POSTCODE: 200021
TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360
http://www.hioki.cn / E-mail: [email protected]
Beijing Office : TEL +86-10-5867-4080/4081
Guangzhou Office : TEL +86-20-38392673/2676
DISTRIBUTED BY
HIOKI SINGAPORE PTE.LTD. :
33 UBI AVENUE 3, #03-02 VERTEX, SINGAPORE 408868
TEL +65-6634-7677 FAX +65-6634-7477
E-mail: [email protected]
HIOKI INDIA PRIVATE LIMITED :
Khandela House, 24 Gulmohar Colony Indore 452 018 (M.P.), India
TEL +91-731-4223901, 4223902 FAX +91-731-4223903
http://www.hioki.in / E-mail: [email protected]
All information correct as of Feb. 3, 2011. All specifications are subject to change without notice.
LR5000sE2-12B