AC centrifugal fans
Technical information
Product line
Bearings
The renowned ebm-papst AC fans are used when DC voltage is not
AC fans with sleeve bearings are powered by Class E insulated motors.
available. The AC range of fans is based on experience gained from
Fans with ball bearings are equipped with Class B, E, or F insulated
decades of development know-how, millions of units in series production,
motors.
and the innovation competence of a world-wide technology pioneer.
Degree of protection
In this catalog, we offer you the broad spectrum of our AC fans. In addition
All ebm-papst fans conform to the requirements of IP 20. Fans
to complete systems, you will also find fans without external housing.
conforming to IP 54 / IP 68 and special degrees of protection are also
They offer economic benefits whenever the air duct design can be
available on request.
integrated in the respective device.
AC voltage
Variety of sizes
The line of AC fans for Euro voltage according to IEC 60038
AC fans are available in a variety of sizes with either air exhaust or air
(230 V ± 10 %) is also available in 115 V.
intake over struts. Silent running models with sleeve bearings. Electrical
connection with plug connection or external exposed connection wires are
Frequencies
available.
AC fans can be operated at frequencies of 50 or 60 Hz. In this case, their
technical data changes accordingly.
2016-01
Shaded-pole or capacitor motors
Fan drives by shaded-pole or capacitor motors, most of which incorporate
Capacitor
the world-famous ebm-papst external rotor principle. The fan blades are
Fans driven by capacitor external motors provide particularly high
directly attached to the external rotor of the external rotor motor. This
operating efficiency. Generally, the required motor run capacitor is already
construction combining high performance with profitability.
integrated in the fan housing.
Flat built AC fans
Overloading
ebm-papst also has AC fans with a particularly flat construction and an
Almost all AC fans are protected against overloading (e. g. due to locked
internal rotor motor. Their advantage: quick start to full speed. A plastic
rotor) – either impedance protected (marked "Impedance protected" or
impeller and the smaller and lighter internal rotor motor result in lower
"Z. P.") or equipped with a thermal switch (marked "Thermally protected"
rotational inertia.
or "Th. P."). The model designation of these fans ends with "S".
232
Information
DC axial fans
Centrifugal fans for AC operation
Page
Air flow
10
m3/h
mm
20
30
40
50
60
70 80 90 100
200
300
400
500 600 700 800 900 1000
2000
3000
c 121 x 37
RL 90
40...42
234
135 x 38
RG 90
47...54
235
180 x 40
RG 125
86...94
236
220 x 56
RG 160
202...223
237
Ø
138 x 40
RER 125
104...115
238
Ø
176 x 54
RER 160
234...274
239
c
c
c
DC centrifugal fans
Series
Dimensions
Overview of air performance
DC fans - specials
Subject to change
n
y pro
ACmaxx / EC fans
tectio
Salt
Page
spra
IP 68
•
•
•
•
•
•
–
•
•
•
•
•
•
234
Centrifugal fans
c 121 x 37
Series
OPTIONAL
yes
/
–
RG 90
yes
/
–
RG 125
yes
–
RG 160
yes
–
Ø 138 x 40
RER 125
yes
–
Ø 176 x 54
RER 160
yes
–
c 135 x 38
c 180 x 40
c 220 x 56
RL 90
•
•
•
•
•
•
P.
–
–
–
–
–
235
236
237
AC axial fans
mm
238
239
Subject to change
Ball bearings
AC centrifugal fans
Sleeve bearings
Accessories
– not yet available
233
2016-01
• available
Representatives
n
ectio
prot
= 54
IP >
nal
ture
d sig
Mois
Spee
SINT
Ball EC sleev
bear
ings e bearin
gs/
VDE
Dim
, UL,
ensio
ns
CSA
Overview of technically feasible designs
Max.
42 m /h
AC centrifugal fans
3
 121 x 37 mm
–
Scroll housing: GRP1) (PBT)
Impeller: GRP1) (PA)
Housing base: Sheet steel
Direction of air flow: Centrifugal: discharge through
window in housing
Direction of rotation: Clockwise, looking towards rotor
Connection:
Via 2 single wires; housing base
with flat plugs 6.3 x 0.8 mm for
ground conductor
Highlights:
Forward-curved impeller
Weight:
680 g
– Material:
–
–
–
–
–
Possible special versions:
(See page 12)
- Moisture protection
- Salt spray protection
- Degree of protection: IP 54
Nominal voltage
Frequency
Sound power level
Sintec sleeve bearings
Ball bearings
Power consumption
Nominal speed
Temperature range
Service life L10
at 40 °C
cfm
VAC
Hz
Bel(A)
/
Watts
rpm-1
°C
Hours
RL 90-18/50
40
23.5
230
50
5.6
20.0
2 450
-10...+50
37 500 / 30 000
RL 90-18/56
40
23.5
230
50
5.6
20.0
2 450
-30...+70
37 500 / 20 000
RL 90-18/00
42
24.7
115
60
6.0
19.5
2 550
-10...+60
37 500 / 25 000
RL 90-18/06
42
24.7
115
60
6.0
19.5
2 550
-30...+85
37 500 / 15 000
Nominal data
Type
Hours
Subject to change
Fan type
2016-01
Air performance measured according to:
ISO 5801.
Installation category A, without contact
protection.
Noise: Total sound power level LWA ISO
103002measured on a hemisphere with a
radius of 2 m;
Sound pressure level LpA measured at 1 m
distance from fan axis.
The values given are applicable only under
the specified measuring conditions and may
differ depending on the installation conditions.
described measurement set-up and may vary
depending on the installation situation.
For detailed information see
http://www.ebmpapst.com/general conditions
234
Connection wires
RL 90-18/50
RL 90-18/00
AWG 18, TR 32
RL 90-18/56
RL 90-18/06
AWG 22
Tin-plated
Curve
Air flow
m3/h
Series RL 90
at T max
Air flow
1) Fiberglass-reinforced plastic
¿
¿
¡
¡
54 m /h
Information
Max.
AC centrifugal fans
3
 135 x 38 mm
– Possible special versions:
Scroll housing: GRP1) (PBT)
(See page 12)
Impeller: GRP1) (PA)
- Moisture protection
Housing base: Sheet steel
- Salt spray protection
Direction of air flow: Centrifugal: discharge through
- Degree of protection: IP 54
window in housing
Direction of rotation: Clockwise,
looking towards rotor
Connection:
To 2 single wires AWG 22.
Highlights:
Forward-curved impeller
Weight:
560 g
–
–
–
–
DC centrifugal fans
–
DC axial fans
– Material:
Sound power level
Sintec sleeve bearings
Ball bearings
Power consumption
Nominal speed
Temperature range
Service life L10
at 40 °C
Hz
Bel(A)
/
Watts
rpm-1
°C
Hours
RG 90-18/50
54
32
230
50
5.8
22.0
2 200
-30...+60
35 000 / 22 500
RG 90-18/56
54
32
230
50
5.8
22.0
2 200
-30...+60
35 000 / 22 500
RG 90-18/00
47
28
115
60
6.2
22.0
1 900
-30...+65
35 000 / 20 000
RG 90-18/06
47
28
115
60
6.2
22.0
1 900
-30...+65
35 000 / 20 000
Hours
DC fans - specials
Frequency
VAC
¿
¿
¡
¡
Finger guards
from p. 242
Tin-p
la
ted
235
2016-01
Air performance measured according to: ISO 5801.
Installation category A, without contact protection.
Noise: Total sound power level LWA ISO 103002
measured on a hemisphere with a radius of 2 m.
Sound pressure level LpA measured at 1 m distance
from fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
Accessories
AC centrifugal fans
AC axial fans
Subject to change
Representatives
Type
ACmaxx / EC fans
Nominal voltage
cfm
Nominal data
Curve
Air flow
m3/h
Series RG 90
at T max
Air flow
1) Fiberglass-reinforced plastic
Max.
94 m /h
AC centrifugal fans
3
 180 x 40 mm
– Possible special versions:
(See page 12)
- Moisture protection
- Salt spray protection
- Degree of protection: IP 54
Scroll housing: GRP1) (PBT)
Impeller: GRP1) (PA)
Housing base: Sheet steel
Direction of air flow: Centrifugal: discharge through
window in housing
Direction of rotation: Clockwise,
looking towards rotor
Connection:
To 2 single wires AWG 22.
Highlights:
Backward-curved impeller
Weight:
850 g
– Material:
–
–
–
–
–
Temperature range
Service life L10
at 40 °C
20.0
2 550
-30...+70
37 500 / 20 000
6.0
19.0
2 750
-30...+80
40 000 / 15 000
cfm
VAC
Hz
Bel(A)
RG 125-19/56
86
51
230
50
RG 125-19/06
94
55
115
60
Type
Subject to change
2016-01
Air performance measured according to: ISO 5801.
Installation category A, without contact protection.
Noise: Total sound power level LWA ISO 103002
measured on a hemisphere with a radius of 2 m.
Sound pressure level LpA measured at 1 m distance
from fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
236
Finger guards
from p. 242
Tin-p
la
ted
Hours
Curve
Nominal speed
5.8
m3/h
Nominal data
at T max
Power consumption
Hours
Sound power level
°C
Frequency
rpm-1
Nominal voltage
Watts
Air flow
/
Air flow
Series RG 125
Sintec sleeve bearings
Ball bearings
1) Fiberglass-reinforced plastic
¿
¡
223 m /h
Information
Max.
AC centrifugal fans
3
 220 x 56 mm
– Possible special versions:
Scroll housing: GRP1) (PBT)
(See page 12)
Impeller: GRP1) (PA)
- Moisture protection
Housing base: Sheet steel
Direction of air flow: Centrifugal: discharge through
window in housing
Direction of rotation: Counterclockwise,
looking towards rotor
Connection:
To 2 single wires AWG 18.
Highlights:
Backward-curved impeller
Weight:
1.7 kg
–
–
–
–
DC centrifugal fans
–
DC axial fans
– Material:
Service life L10
at 40 °C
2 750
-30...+70
30 000 / 15 000
6.9
50.0
3 050
-30...+80
27 500 / 12 500
cfm
VAC
Hz
Bel(A)
RG 160-28/56S
202
119
230
50
RG 160-28/06S
223
131
115
60
Hours
DC fans - specials
Temperature range
47.0
m3/h
Curve
Nominal speed
6.6
Type
Nominal data
at T max
Power consumption
Hours
Sound power level
°C
Frequency
rpm-1
Nominal voltage
Watts
Air flow
/
Air flow
Series RG 160
Sintec sleeve bearings
Ball bearings
1) Fiberglass-reinforced plastic
¿
¡
ted
237
Representatives
Finger guards
from p. 242
Tin-p
la
2016-01
Air performance measured according to: ISO 5801.
Installation category A, without contact protection.
Noise: Total sound power level LWA ISO 103002
measured on a hemisphere with a radius of 2 m.
Sound pressure level LpA measured at 1 m distance
from fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
Accessories
AC centrifugal fans
AC axial fans
ACmaxx / EC fans
Subject to change
Max.
115 m /h
AC centrifugal fans
3
Ø 138 x 40 mm
Scroll housing: GRP1) (PBT)
Impeller: GRP1) (PA)
with sheet steel reinforced
Direction of air flow: centrifugal
Direction of rotation: Clockwise,
looking towards rotor
Connection:
To 2 single wires AWG 22.
Highlights:
Backward-curved impeller
Weight:
500 g
– Material:
–
–
–
–
–
– Possible special versions:
(See page 12)
- Moisture protection
- Salt spray protection
- Degree of protection: IP 54
Temperature range
Service life L10
at 40 °C
19.0
2 600
-30...+60
37 500 / 22 500
6.5
18.0
2 850
-30...+70
40 000 / 20 000
m3/h
cfm
VAC
Hz
Bel(A)
RER 125-19/56
104
61
230
50
RER 125-19/06
115
68
115
60
Hours
Curve
Nominal speed
6.2
Type
Nominal data
at T max
Power consumption
Hours
Sound power level
°C
Frequency
rpm-1
Nominal voltage
Watts
Air flow
/
Air flow
Series RER 125
Sintec sleeve bearings
Ball bearings
1) Fiberglass-reinforced plastic
¿
¡
Subject to change
The air flow and sound level of the centrifugal
fans without external housing depend on their
individual installation conditions. The stated
air flow and noise levels have been measured
under the following conditions:
Centrifugal fan mounted on a base plate
220 x 220 mm.
Cover plate 220 x 220 mm with an air inlet of
Ø 86 mm, concentric to the impeller.
2016-01
Air performance measured according to: ISO 5801.
Installation category A, with ebm-papst inlet ring without
contact protection.
Noise: Total sound power level LWA ISO 103002
measured on a hemisphere with a distance of 2 m.
Sound pressure level LpA measured at 1 m distance
from fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
238
Finger guards
from p. 242
Inlet rings
from p. 252
Tin-plated
274 m /h
Information
Max.
AC centrifugal fans
3
Ø 176 x 54 mm
–
–
–
DC axial fans
–
–
– Possible special versions:
(See page 12)
- Moisture protection
DC centrifugal fans
Scroll housing: GRP1) (PBT)
Impeller: GRP1) (PA)
with sheet steel reinforced
Direction of air flow: centrifugal
Direction of rotation: Counterclockwise,
looking towards rotor
Connection:
To 2 single wires AWG 18.
Highlights:
Backward-curved impeller
Weight:
1.0 kg
– Material:
Service life L10
at 40 °C
2 800
-30...+60
30 000 / 20 000
6.8
46.0
3 250
-30...+70
30 000 / 15 000
cfm
VAC
Hz
Bel(A)
RER 160-28/56S
234
138
230
50
RER 160-28/06S
274
161
115
60
Hours
DC fans - specials
Temperature range
45.0
m3/h
Curve
Nominal speed
6.6
Type
Nominal data
at T max
Power consumption
Hours
Sound power level
°C
Frequency
rpm-1
Nominal voltage
Watts
Air flow
/
Air flow
Series RER 160
Sintec sleeve bearings
Ball bearings
1) Fiberglass-reinforced plastic
¿
¡
ACmaxx / EC fans
Subject to change
AC axial fans
The air flow and sound level of the centrifugal
fans without external housing depend on their
individual installation conditions. The stated
air flow and noise levels have been measured
under the following conditions:
AC centrifugal fans
Centrifugal fan mounted on a base plate
260 x 260 mm.
Cover plate 260 x 260 mm with an air inlet of
Ø 100 mm, concentric to the impeller.
Finger guards
from p. 242
Inlet rings
from p. 252
239
2016-01
Air performance measured according to: ISO 5801.
Installation category A, with ebm-papst inlet ring without
contact protection.
Noise: Total sound power level LWA ISO 103002
measured on a hemisphere with a distance of 2 m.
Sound pressure level LpA measured at 1 m distance
from fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
Representatives
Accessories
Tin-plated
2016-01
240