231 Representatives Accessories AC centrifugal fans AC axial fans ACmaxx / EC fans DC fans - specials DC centrifugal fans AC centrifugal fan overview AC centrifugal fans 2016-01 DC axial fans AC centrifugal fans 233 234 Information AC centrifugal fans Technical information Product line Bearings The renowned ebm-papst AC fans are used when DC voltage is not AC fans with sleeve bearings are powered by Class E insulated motors. available. The AC range of fans is based on experience gained from Fans with ball bearings are equipped with Class B, E, or F insulated decades of development know-how, millions of units in series production, motors. and the innovation competence of a world-wide technology pioneer. Degree of protection In this catalog, we offer you the broad spectrum of our AC fans. In addition All ebm-papst fans conform to the requirements of IP 20. Fans to complete systems, you will also find fans without external housing. conforming to IP 54 / IP 68 and special degrees of protection are also They offer economic benefits whenever the air duct design can be available on request. integrated in the respective device. AC voltage Variety of sizes The line of AC fans for Euro voltage according to IEC 60038 AC fans are available in a variety of sizes with either air exhaust or air (230 V ± 10 %) is also available in 115 V. intake over struts. Silent running models with sleeve bearings. Electrical connection with plug connection or external exposed connection wires are Frequencies available. AC fans can be operated at frequencies of 50 or 60 Hz. In this case, their technical data changes accordingly. 2016-01 Shaded-pole or capacitor motors Fan drives by shaded-pole or capacitor motors, most of which incorporate Capacitor the world-famous ebm-papst external rotor principle. The fan blades are Fans driven by capacitor external motors provide particularly high directly attached to the external rotor of the external rotor motor. This operating efficiency. Generally, the required motor run capacitor is already construction combining high performance with profitability. integrated in the fan housing. Flat built AC fans Overloading ebm-papst also has AC fans with a particularly flat construction and an Almost all AC fans are protected against overloading (e. g. due to locked internal rotor motor. Their advantage: quick start to full speed. A plastic rotor) – either impedance protected (marked "Impedance protected" or impeller and the smaller and lighter internal rotor motor result in lower "Z. P.") or equipped with a thermal switch (marked "Thermally protected" rotational inertia. or "Th. P."). The model designation of these fans ends with "S". 232 Information DC axial fans Centrifugal fans for AC operation Page Air flow 10 m3/h mm 20 30 40 50 60 70 80 90 100 200 300 400 500 600 700 800 900 1000 2000 3000 c 121 x 37 RL 90 40...42 234 135 x 38 RG 90 47...54 235 180 x 40 RG 125 86...94 236 220 x 56 RG 160 202...223 237 Ø 138 x 40 RER 125 104...115 238 Ø 176 x 54 RER 160 234...274 239 c c c DC centrifugal fans Series Dimensions Overview of air performance DC fans - specials Subject to change n y pro ACmaxx / EC fans tectio Salt Page spra IP 68 • • • • • • – • • • • • • 234 Centrifugal fans c 121 x 37 Series OPTIONAL yes / – RG 90 yes / – RG 125 yes – RG 160 yes – Ø 138 x 40 RER 125 yes – Ø 176 x 54 RER 160 yes – c 135 x 38 c 180 x 40 c 220 x 56 RL 90 • • • • • • P. – – – – – 235 236 237 AC axial fans mm 238 239 Subject to change Ball bearings AC centrifugal fans Sleeve bearings Accessories – not yet available 233 2016-01 • available Representatives n ectio prot = 54 IP > nal ture d sig Mois Spee SINT Ball EC sleev bear ings e bearin gs/ VDE Dim , UL, ensio ns CSA Overview of technically feasible designs Max. 42 m /h AC centrifugal fans 3 121 x 37 mm – Scroll housing: GRP1) (PBT) Impeller: GRP1) (PA) Housing base: Sheet steel Direction of air flow: Centrifugal: discharge through window in housing Direction of rotation: Clockwise, looking towards rotor Connection: Via 2 single wires; housing base with flat plugs 6.3 x 0.8 mm for ground conductor Highlights: Forward-curved impeller Weight: 680 g – Material: – – – – – Possible special versions: (See page 12) - Moisture protection - Salt spray protection - Degree of protection: IP 54 Nominal voltage Frequency Sound power level Sintec sleeve bearings Ball bearings Power consumption Nominal speed Temperature range Service life L10 at 40 °C cfm VAC Hz Bel(A) / Watts rpm-1 °C Hours RL 90-18/50 40 23.5 230 50 5.6 20.0 2 450 -10...+50 37 500 / 30 000 RL 90-18/56 40 23.5 230 50 5.6 20.0 2 450 -30...+70 37 500 / 20 000 RL 90-18/00 42 24.7 115 60 6.0 19.5 2 550 -10...+60 37 500 / 25 000 RL 90-18/06 42 24.7 115 60 6.0 19.5 2 550 -30...+85 37 500 / 15 000 Nominal data Type Hours Subject to change Fan type 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002measured on a hemisphere with a radius of 2 m; Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. described measurement set-up and may vary depending on the installation situation. For detailed information see http://www.ebmpapst.com/general conditions 234 Connection wires RL 90-18/50 RL 90-18/00 AWG 18, TR 32 RL 90-18/56 RL 90-18/06 AWG 22 Tin-plated Curve Air flow m3/h Series RL 90 at T max Air flow 1) Fiberglass-reinforced plastic ¿ ¿ ¡ ¡ 54 m /h Information Max. AC centrifugal fans 3 135 x 38 mm – Possible special versions: Scroll housing: GRP1) (PBT) (See page 12) Impeller: GRP1) (PA) - Moisture protection Housing base: Sheet steel - Salt spray protection Direction of air flow: Centrifugal: discharge through - Degree of protection: IP 54 window in housing Direction of rotation: Clockwise, looking towards rotor Connection: To 2 single wires AWG 22. Highlights: Forward-curved impeller Weight: 560 g – – – – DC centrifugal fans – DC axial fans – Material: Sound power level Sintec sleeve bearings Ball bearings Power consumption Nominal speed Temperature range Service life L10 at 40 °C Hz Bel(A) / Watts rpm-1 °C Hours RG 90-18/50 54 32 230 50 5.8 22.0 2 200 -30...+60 35 000 / 22 500 RG 90-18/56 54 32 230 50 5.8 22.0 2 200 -30...+60 35 000 / 22 500 RG 90-18/00 47 28 115 60 6.2 22.0 1 900 -30...+65 35 000 / 20 000 RG 90-18/06 47 28 115 60 6.2 22.0 1 900 -30...+65 35 000 / 20 000 Hours DC fans - specials Frequency VAC ¿ ¿ ¡ ¡ Finger guards from p. 242 Tin-p la ted 235 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Accessories AC centrifugal fans AC axial fans Subject to change Representatives Type ACmaxx / EC fans Nominal voltage cfm Nominal data Curve Air flow m3/h Series RG 90 at T max Air flow 1) Fiberglass-reinforced plastic Max. 94 m /h AC centrifugal fans 3 180 x 40 mm – Possible special versions: (See page 12) - Moisture protection - Salt spray protection - Degree of protection: IP 54 Scroll housing: GRP1) (PBT) Impeller: GRP1) (PA) Housing base: Sheet steel Direction of air flow: Centrifugal: discharge through window in housing Direction of rotation: Clockwise, looking towards rotor Connection: To 2 single wires AWG 22. Highlights: Backward-curved impeller Weight: 850 g – Material: – – – – – Temperature range Service life L10 at 40 °C 20.0 2 550 -30...+70 37 500 / 20 000 6.0 19.0 2 750 -30...+80 40 000 / 15 000 cfm VAC Hz Bel(A) RG 125-19/56 86 51 230 50 RG 125-19/06 94 55 115 60 Type Subject to change 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 236 Finger guards from p. 242 Tin-p la ted Hours Curve Nominal speed 5.8 m3/h Nominal data at T max Power consumption Hours Sound power level °C Frequency rpm-1 Nominal voltage Watts Air flow / Air flow Series RG 125 Sintec sleeve bearings Ball bearings 1) Fiberglass-reinforced plastic ¿ ¡ 223 m /h Information Max. AC centrifugal fans 3 220 x 56 mm – Possible special versions: Scroll housing: GRP1) (PBT) (See page 12) Impeller: GRP1) (PA) - Moisture protection Housing base: Sheet steel Direction of air flow: Centrifugal: discharge through window in housing Direction of rotation: Counterclockwise, looking towards rotor Connection: To 2 single wires AWG 18. Highlights: Backward-curved impeller Weight: 1.7 kg – – – – DC centrifugal fans – DC axial fans – Material: Service life L10 at 40 °C 2 750 -30...+70 30 000 / 15 000 6.9 50.0 3 050 -30...+80 27 500 / 12 500 cfm VAC Hz Bel(A) RG 160-28/56S 202 119 230 50 RG 160-28/06S 223 131 115 60 Hours DC fans - specials Temperature range 47.0 m3/h Curve Nominal speed 6.6 Type Nominal data at T max Power consumption Hours Sound power level °C Frequency rpm-1 Nominal voltage Watts Air flow / Air flow Series RG 160 Sintec sleeve bearings Ball bearings 1) Fiberglass-reinforced plastic ¿ ¡ ted 237 Representatives Finger guards from p. 242 Tin-p la 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Accessories AC centrifugal fans AC axial fans ACmaxx / EC fans Subject to change Max. 115 m /h AC centrifugal fans 3 Ø 138 x 40 mm Scroll housing: GRP1) (PBT) Impeller: GRP1) (PA) with sheet steel reinforced Direction of air flow: centrifugal Direction of rotation: Clockwise, looking towards rotor Connection: To 2 single wires AWG 22. Highlights: Backward-curved impeller Weight: 500 g – Material: – – – – – – Possible special versions: (See page 12) - Moisture protection - Salt spray protection - Degree of protection: IP 54 Temperature range Service life L10 at 40 °C 19.0 2 600 -30...+60 37 500 / 22 500 6.5 18.0 2 850 -30...+70 40 000 / 20 000 m3/h cfm VAC Hz Bel(A) RER 125-19/56 104 61 230 50 RER 125-19/06 115 68 115 60 Hours Curve Nominal speed 6.2 Type Nominal data at T max Power consumption Hours Sound power level °C Frequency rpm-1 Nominal voltage Watts Air flow / Air flow Series RER 125 Sintec sleeve bearings Ball bearings 1) Fiberglass-reinforced plastic ¿ ¡ Subject to change The air flow and sound level of the centrifugal fans without external housing depend on their individual installation conditions. The stated air flow and noise levels have been measured under the following conditions: Centrifugal fan mounted on a base plate 220 x 220 mm. Cover plate 220 x 220 mm with an air inlet of Ø 86 mm, concentric to the impeller. 2016-01 Air performance measured according to: ISO 5801. Installation category A, with ebm-papst inlet ring without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a distance of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 238 Finger guards from p. 242 Inlet rings from p. 252 Tin-plated 274 m /h Information Max. AC centrifugal fans 3 Ø 176 x 54 mm – – – DC axial fans – – – Possible special versions: (See page 12) - Moisture protection DC centrifugal fans Scroll housing: GRP1) (PBT) Impeller: GRP1) (PA) with sheet steel reinforced Direction of air flow: centrifugal Direction of rotation: Counterclockwise, looking towards rotor Connection: To 2 single wires AWG 18. Highlights: Backward-curved impeller Weight: 1.0 kg – Material: Service life L10 at 40 °C 2 800 -30...+60 30 000 / 20 000 6.8 46.0 3 250 -30...+70 30 000 / 15 000 cfm VAC Hz Bel(A) RER 160-28/56S 234 138 230 50 RER 160-28/06S 274 161 115 60 Hours DC fans - specials Temperature range 45.0 m3/h Curve Nominal speed 6.6 Type Nominal data at T max Power consumption Hours Sound power level °C Frequency rpm-1 Nominal voltage Watts Air flow / Air flow Series RER 160 Sintec sleeve bearings Ball bearings 1) Fiberglass-reinforced plastic ¿ ¡ ACmaxx / EC fans Subject to change AC axial fans The air flow and sound level of the centrifugal fans without external housing depend on their individual installation conditions. The stated air flow and noise levels have been measured under the following conditions: AC centrifugal fans Centrifugal fan mounted on a base plate 260 x 260 mm. Cover plate 260 x 260 mm with an air inlet of Ø 100 mm, concentric to the impeller. Finger guards from p. 242 Inlet rings from p. 252 239 2016-01 Air performance measured according to: ISO 5801. Installation category A, with ebm-papst inlet ring without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a distance of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Representatives Accessories Tin-plated 2016-01 240