25 Representatives Accessories AC centrifugal fans AC axial fans ACmaxx / EC fans DC fans - specials DC centrifugal fans DC axial fan overview DC axial fan / DC diagonal fan 2016-01 DC axial fans DC axial fans 27 31 Information DC axial fans Technical information Product line Voltage range ebm-papst offers you the widest full product line of DC axial and diagonal Many of our DC fans can be operated on voltages that are up to 50% fans from 25 mm to 280 mm in size. Every single type of fan can be lower and 25% higher than their nominal voltage (see voltage range in optimally integrated in the respective device concept. The highly the technical tables). This allows the air performance to be adapted to the economical brushless motor technology of these fans provides a unique cooling requirements and the noise to be reduced, even if the fan does variety of intelligent innovations at prices that would have been not have a control input. unthinkable a few years ago. Closed-loop speed control and monitoring Electronic protection against reverse polarity Closed-loop speed control and function monitoring are becoming ebm-papst DC fans have electronically commutated drives with electronic increasingly important in many applications. ebm-papst offers many fans protection against reverse polarity. The electronics are integrated in the in the standard design with a control input and open-collector speed fan’s impeller hub to save space. signal. Product life expectancy S-Force A distinctive feature of DC fan technology is the amazing product life The new S-Force fans with their extremely high blower capacity of up to expectancy. The outstanding efficiency of the brushless drive results in 1100 m3/h and pressure increase of up to 1400 pascals are capable of lower heat stress for the bearings, which significantly increases the dealing with the extreme heat load. If needed, these fans can produce up service life of the fan. to 100% more output under full load, and they work with a much broader delivery bandwidth than current models. This makes them ideal for Degree of protection equipment and systems with a high density of components. Thanks to DC fans with sleeve and ball bearings are powered by class E insulated intelligent motor features, they can be adapted individually for any motors. All ebm-papst fans conform to the requirements of degree of application. S-Force fans are available in standard dimensions. The air protection IP 20. Fans conforming to IP 54 / IP 68 and special degrees of flow rate is amazing! protection are also available. S-Panther S-Panther power delivered quietly. Wherever there is need for power and reduced noise, fans from the S-Panther range are the right solution. A strong pressure saddle curve at optimum air flow provides 2016-01 the power of a real big cat, an S-Panther. 26 2.3...4.6 6...9 10...13.5 24...38 11...20 19...33 21...67 40...58 21...56 16...41 70...82 28...44 32...117 33...79 20...58 32...80 132...222 61...102 44...84 56...133 130...280 145...270 94...170 91 200...225 95...204 65...170 Information Page 30 40 50 60 70 80 90 100 200 300 400 500 600 700 800 900 1000 2000 2500 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 NEW DC centrifugal fans 250 400 F 400 420 J 500 F 600 F 620 630 600 N 600 N VARIOFAN 600 J 700 F 8450 8400 N 8400 N VARIOFAN 8300 8200 J 3400 N 3400 N VARIOFAN 3300 N 3200 J 3250 J 4400 F 4400 F 4400 FN 4300 4300 VARIOFAN 20 DC fans - specials 25 x 8 40 x 10 c 40 x 20 c 40 x 28 c 50 x 15 c 60 x 15 c 60 x 25 c 60 x 25 c 60 x 25 c 60 x 25 c 60 x 32 c 70 x 15 c 80 x 25 c 80 x 25 c 80 x 25 c 80 x 32 c 80 x 38 c 92 x 25 c 92 x 25 c 92 x 32 c 92 x 38 c 92 x 38 c 119 x 25 Ø 127 c 119 x 25 c 119 x 32 c 119 x 32 c 10 ACmaxx / EC fans m3/h mm c Air flow Series Dimension Overview of air performance DC axial fans Axial fans for DC operation Subject to change 50 60 70 80 90 100 200 300 400 500 600 700 800 900 1000 2000 2500 AC axial fans 40 AC centrifugal fans 30 Accessories 20 27 Representatives 10 2016-01 m3/h Axial fans for DC operation m3/h mm c 119 x 38 119 x 38 c 119 x 38 c 119 x 38 c 119 x 38 c 127 x 38 c 127 x 38 c 135 x 38 c 140 x 51 c 140 x 51 Ø 150 x 38 Ø 150 x 55 172 x 150 x 51 172 x 150 x 51 172 x 160 x 51 172 x 160 x 51 172 x 160 x 51 Ø 172 x 51 Ø 172 x 51 Ø 172 x 51 Ø 172 x 51 Ø 172 x 51 220x200x51 c 225 x 80 c 225 x 89 Ø 250 Ø 300 c 4400 4100 N 4100 NHH..NH6 4100 NH7..NH8 DV 4100 5200 N DV 5200 5100 N 5300 5300 TD 7100 N 7200 N 6400 6400 TD DV 6400 DV 6400 TD 6300 TD 6300 N 6300 NTD 6300 6300 TD DV 6300 TD 2200 FTD K1G 200 K3G 200 W1G 250 *1G 300 Page Air flow Series Dimension Overview of air performance 10 20 30 40 50 60 70 80 90 100 200 300 400 500 600 700 800 900 1000 2000 2500 100...285 160...237 260...440 500...570 280 187...340 270...320 260 340 410...670 308...360 360 350...480 90...900 530 100...680 710...930 540...685 970...1030 395...545 600...930 630...1100 790...1220 1020...1245 725...1650 2070 2320...2345 58/59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 84 86 88 Subject to change 2016-01 m3/h 28 10 20 30 40 50 60 70 80 90 100 200 300 400 500 600 700 800 900 1000 2000 2500 Information Axial fans for DC operation ation f rot • – – – – – – • – – – – 31 c 40 x 10 400 F yes • • – – – – – – • – – – – 32 c 40 x 20 400 yes • • – – – • – – • – – – – 33 c 40 x 28 420 J yes • • – • – • – – • – – • – 34 c 50 x 15 500 F yes • • – – – • – – • – – – – 35 c 60 x 15 600 F yes • • – – – • – – • – – – – 36 c 60 x 25 620 yes • • • • • • • – • – – – – 37 c 60 x 25 630 yes • • • • – • • – • • • • – 38 c 60 x 25 600 N yes / • • – – – – – – • • • – – 39 c 60 x 25 600 N VARIOFAN yes / • • – • • – – – • – – – – 40 c 60 x 32 600 J yes • • – • – • • – • – – – – 41 c 70 x 15 700 F yes • • – – – – • – – – – 42 c 80 x 25 8450 yes / • • • • • • • – • – – – – 43 c 80 x 25 8400 N yes / • • • • • • • – • • • – – 44 c 80 x 25 8400 N VARIOFAN yes • • – • • – – • – – – – 45 c 80 x 32 8300 yes • • • • • • • – • • • • – 46 c 80 x 38 8200 J yes • • • • • • • – • • – – – 47 c 92 x 25 3400 N yes • • • • • • • – • • • – – 48 c 92 x 25 3400 N VARIOFAN yes • • – • • – – • – – – – 49 c 92 x 38 3300 N yes • • – • • • • – • • • • – 50 c 92 x 38 3200 J yes • • • • • • • – • • • – – 51 c 92 x 38 3250 J yes • • – • • • • – • • • • – 52 c 119 x 25 53 NEW Ø 172 OPTIONAL / – – – – – P. 4400 F yes • • • • • • • – • – – – – 4400 F yes • • • • • • • – • – – – • 54 yes • • • • • • • – • – – – – 55 • • • • • • • – • • • • – 56 • • • • • • • – • – – – – 57 c 119 x 25 4400 FN c 119 x 32 4300 yes c 119 x 32 4300 VARIOFAN yes / / DC centrifugal fans yes Please consult your customer support representative about the feasibility of your special variant. DC fans - specials 250 ACmaxx / EC fans Series c 25 x 8 AC axial fans mm Please note that these special versions are not possible for all voltages and speeds, and not in all combinations. The special versions are designed for specific customers and projects. As a rule, they are not available off the shelf and are based on minimum quantities. Subject to change Accessories AC centrifugal fans Sleeve bearings Ball bearings 29 2016-01 – not yet available • Available Representatives Axial fans DC axial fans Salt spra y pro Reve tectio rsible n direc Page tion o VDE , UL, o/N oG Alarm o alarm with spee d lim Exte rnal it temp Inter eratu nal t re se emp nso eratu PWM re se r con nsor Analo trol inpu t g co ntro l inp Mult ut i-op tions cont rol in Mois put ture prot IP > e c tion = 54 IP 68 CSA n ensio Dim SINT EC s leeve beari ngs Spee / ball d sig beari nal ngs G Overview of technically feasible designs Axial fans for DC operation ation f rot Salt spra y pro Reve tectio rsible n direc Page tion o VDE , UL, o/N oG Alarm o alarm with spee d lim Exte rnal it temp Inter eratu nal t r e emp sens eratu PWM o re se r con nsor Analo trol inpu t g co ntro l inp Mult ut i-op tions cont rol in Mois put ture prot IP > e c t ion = 54 IP 68 CSA n ensio Dim SINT EC s leeve beari ngs Spee / ball d sig beari nal ngs G Overview of technically feasible designs Axial fans mm Series c 119 x 38 4400 ja OPTIONAL c 119 x 38 4100 N ja c 119 x 38 4100 NH..NH6 ja c 119 x 38 4100 NH7..NH8 c 119 x 38 DV 4100 c 127 x 38 c 127 x 38 c 135 x 38 c 140 x 51 c 140 x 51 • • • • • • – • • – – – 58/59 • • • • • • • – • • • • – 60 • • • • • • • – • • • • – 61 ja • • • • • • • – • – – • – 62 ja • • • • • • • – • • • • – 63 5200 N ja • • • • • • • – • • • • – 64 DV 5200 ja • • • • • • • – • • – • – 65 5100 N ja • • • • • • • – • • – • – 66 5300 ja • • • • • • • – • • – • – 67 5300 TD ja • • • • • • • • • • – • – 68 Ø 150 x 38 7100 N ja • • • • • • • – • • • • – 69 Ø 150 x 55 7200 N ja • • • • • • • – • • • • – 70 172 x 150 x 51 6400 ja • • • • • • • – • • – • – 71 172 x 150 x 51 6400 TD ja • • • • • • • – • • – • • 72 172 x 150 x 51 DV 6400 ja • • • • • • • – • • – • – 73 172 x 150 x 51 DV 6400 TD ja • • • • • • • – • • – • • 74 172 x 160 x 51 6300 TD ja • • • • • • • • • • – • – 75 / Ø 172 x 51 6300 N ja • • • • • • • • • • • • – 76 Ø 172 x 51 6300 NTD ja • • • • • • • • • • – • – 77 Ø 172 x 51 6300 ja • • • • • • • – • • – • – 78 Ø 172 x 51 6300 TD ja • • • • • • • • • • – • – 79 Ø 172 x 51 DV 6300 TD ja • • • • • • • • • • – • – 80 Ø 200 x 51 2200 FTD ja • • • • • • • • • • – • – 81 c 225 x 80 K1G 200 ja • • • • – • • • • – – • – 82 c 225 x 89 K3G 200 ja • • • • – • • • • – – • – 84 Subject to alterations 2016-01 – not yet available • Available 30 P. • Sleeve bearings Ball bearings Please note that these special versions are not possible for all voltages and speeds, and not in all combinations. The special versions are designed for specific customers and projects. As a rule, they are not available off the shelf and are based on minimum quantities. Please consult your customer support representative about the feasibility of your special variant. Information 4.6 m /h DC axial fans 3 25 x 8 mm – – DC centrifugal fans – – DC axial fans – Possible special versions: (See chapter DC fans - specials) - Speed signal - Moisture protection Housing: GRP1) (PBT) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Counterclockwise, looking towards rotor Connection: Via single wires AWG 28, TR 64 Weight: 5g – Material: cfm VDC VDC 255 M 2.3 1.2 5 4.5...5.5 5 <3 0.2 6 500 -10...+70 45 000 / 17 500 47 500 255 N 3.5 1.9 5 4.5...5.5 16 <3 0.4 9 600 -10...+70 40 000 / 15 000 42 500 255 H 4.6 2.6 5 4.5...5.5 23 4.4 0.6 12 000 -10...+55 35 000 / 15 000* 37 500 252 N 3.4 1.9 12 10...14 15 <3 0.5 9 000 -10...+70 40 000 / 15 000 42 500 252 H 4.6 2.6 12 10...14 23 4.4 0.7 12 000 -10...+55 35 000 / 15 000* 37 500 dB(A) Bel(A) Hours Hours DC fans - specials m3/h ¿ ¡ ¬ ¡ ¬ ACmaxx / EC fans Type Nominal data Curve Life expectancy L10IPC (40 °C) see page 17 Service life L10 (60 °C) ebm-papst standard Service life L10 (20 °C) ebm-papst standard Temperature range Power consumption Nominal speed Sintec sleeve bearings Ball bearings Sound power level °C Voltage range rpm-1 Nominal voltage Watts Air flow / Air flow Series 250 Sound pressure level 1) Fiberglass-reinforced plastic Subject to change Finger guards from p. 242 Tin-p la ted 31 2016-01 Air performance measured as per: ISO 5801. Installation category A, without accidental contact. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Accessories AC centrifugal fans AC axial fans * at 55 °C Representatives Max. Max. 9 m /h DC axial fans 3 40 x 10 mm Housing: GRP1) (PBT) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Counterclockwise, looking towards rotor Connection: Via single wires AWG 28, TR 64 Highlights: Some models are suitable for use at high ambient temperatures Weight: 17 g – Material: – – – – – – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - Moisture protection Hours 5 400 -20...+70 45 000 / 17 500 47 500 6 000 -20...+70 45 000 / 17 500 47 500 0.5 4 300 -20...+70 45 000 / 17 500 47 500 0.7 5 400 -20...+70 45 000 / 17 500 47 500 4.6 0.8 6 000 -20...+70 45 000 / 17 500 47 500 22.1 4.4 0.8 5 400 -20...+70 45 000 / 17 500 47 500 26.0 4.4 0.9 6 000 -20...+70 45 000 / 17 500 47 500 Air flow Nominal voltage Voltage range m3/h cfm VDC VDC 405 F 8 4.7 5 4.5...5.5 22.1 4.4 0.7 405 FH 9 5.3 5 4.5...5.5 26.0 4.6 0.9 412 FM 6 3.5 12 10...14 17.0 3.8 412 F 8 4.7 12 10...14 22.1 4.4 412 FH 9 5.3 12 10...14 26.0 414 F 8 4.7 24 20...28 414 FH 9 5.3 24 21.6...26.4 dB(A) Bel(A) Hours Model with temperature range up to +85 °C. 412 FM-074 6 3.5 12 10...14 17.0 3.8 0.4 4 300 -20...+85 45 000 / 17 500 47 500 412 F-130 8 4.7 12 10...14 22.1 4.4 0.6 5 400 -20...+85 45 000 / 17 500 47 500 412 FH-132 9 5.3 12 10...14 26.0 4.6 0.8 6 000 -20...+85 45 000 / 17 500 47 500 Subject to change 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 32 Finger guards from p. 242 Tin-p la ted Curve Life expectancy L10IPC (40 °C) see page 17 Service life L10 (60 °C) ebm-papst standard °C Type Nominal data Service life L10 (20 °C) ebm-papst standard rpm-1 Sound power level Temperature range Power consumption Watts Nominal speed Sintec sleeve bearings Ball bearings / Air flow Series 400 F Sound pressure level 1) Fiberglass-reinforced plastic ¡ ¬ ¿ ¡ ¬ ¡ ¬ ¿ ¡ ¬ Information 13.5 m /h DC axial fans 3 40 x 20 mm – – – – – – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - PWM control input - Moisture protection DC axial fans Housing: GRP1) (PBT) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Counterclockwise, looking towards rotor Connection: Via single wires AWG 28, TR 64 Highlights: Some models are suitable for use at high ambient temperatures Weight: 27 g – Material: DC centrifugal fans Max. -20...+70 50 000 / 20 000 52 500 0.8 6 000 -20...+70 50 000 / 20 000 52 500 4.7 1.6 8 100 -20...+60 45 000 / 17 500 47 500 Air flow Nominal voltage Voltage range VDC VDC 405 10.0 5.9 5 4.5...5.5 18 3.8 0.9 412 10.0 5.9 12 10...14 18 3.8 412 H 13.5 7.9 12 10...14 29 dB(A) Bel(A) Hours ¿ ¿ ¡ 414 10.0 5.9 24 20...28 18 3.8 1.0 6 000 -20...+70 50 000 / 20 000 52 500 414 H 13.5 7.9 24 20...26.5 29 4.7 1.7 8 100 -20...+60 45 000 / 17 500 47 500 ¿ ¡ 12 10...14 18 3.8 0.8 6 000 -20...+85 50 000 / 20 000 52 500 ¿ Model with temperature range up to +85 °C. 412-099 10.0 5.9 DC fans - specials 6 000 cfm ACmaxx / EC fans Hours m3/h Curve Life expectancy L10IPC (40 °C) see page 17 Service life L10 (60 °C) ebm-papst standard °C Type Nominal data Service life L10 (20 °C) ebm-papst standard rpm-1 Sound power level Temperature range Power consumption Watts Nominal speed Sintec sleeve bearings Ball bearings / Air flow Series 400 Sound pressure level 1) Fiberglass-reinforced plastic ted 33 Representatives Finger guards from p. 242 Tin-p la 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Accessories AC centrifugal fans AC axial fans Subject to change Max. 38 m /h DC axial fans 3 40 x 28 mm Housing: GRP1) (PBT) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Counterclockwise, looking towards rotor Connection: Via single wires AWG 28, UL 1061 Weight: 45 g – Material: – – – – – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - External temperature sensor - PWM control input - Moisture protection - Salt spray protection m3/h cfm VDC VDC 422 JM 24 14.2 12 8...13.8 42 5.5 2.4 11 400 -20...+70 75 000 / 37 500 127 500 422 JN 31 18.3 12 8...13.8 48 6.0 4.1 14 250 -20...+70 67 500 / 35 000 115 000 422 JH 38 22.4 12 8...13.8 54 6.6 6.9 17 250 -20...+70 60 000 / 30 000 102 500 424 JM 24 14.2 24 16...28 42 5.5 2.7 11 400 -20...+70 75 000 / 37 500 127 500 424 JN 31 18.3 24 16...28 48 6.0 4.3 14 250 -20...+70 67 500 / 35 000 115 000 424 JH 38 22.4 24 16...26.4 54 6.6 6.9 17 250 -20...+65 60 000 / 32 500 102 500 Nominal data Type dB(A) Bel(A) Hours Hours Curve Life expectancy L10IPC (40 °C) see page 17 Service life L10 (Tmax) ebm-papst standard Service life L10 (40 °C) ebm-papst standard Temperature range Power consumption Nominal speed Sintec sleeve bearings Ball bearings Sound power level °C Voltage range rpm-1 Nominal voltage Watts Air flow / Air flow Series 420 J Sound pressure level 1) Fiberglass-reinforced plastic ¿ ¡ ¬ ¿ ¡ ¬ Subject to change Tin-plated 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 34 Finger guards from p. 242 Ø 42,5 ± 0,3 Information 20 m /h DC axial fans 3 50 x 15 mm – – – DC axial fans – – – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - PWM control input - Moisture protection DC centrifugal fans Housing: GRP1) (PBT) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Counterclockwise, looking towards rotor Connection: Via single wires AWG 28, TR 64 Highlights: Some models are suitable for use at high ambient temperatures Weight: 27 g – Material: 52 500 0.9 5 000 -20...+70 50 000 / 20 000 52 500 VDC 512 F 20 11.8 12 10.8...13.2 30 4.5 0.8 514 F 20 11.8 24 21.6...26.4 30 4.5 Hours Model with temperature range up to +85 °C. 512 FL-547 11 6.5 12 10.2...13.8 18 3.7 0.4 3 000 -20...+85 50 000 / 20 000 52 500 512 F-532 20 11.8 12 10.8...13.2 30 4.5 0.9 5 000 -20...+85 50 000 / 20 000 52 500 DC fans - specials 50 000 / 20 000 VDC ¡ ¡ ¿ ¡ ACmaxx / EC fans -20...+70 cfm Curve Life expectancy L10IPC (40 °C) see page 17 5 000 m3/h dB(A) Bel(A) Service life L10 (60 °C) ebm-papst standard Hours Type Nominal data Service life L10 (20 °C) ebm-papst standard Temperature range Power consumption °C Voltage range rpm-1 Nominal voltage Nominal speed Sintec sleeve bearings Ball bearings Watts Air flow Sound power level / Air flow Series 500 F Sound pressure level 1) Fiberglass-reinforced plastic AC centrifugal fans AC axial fans Subject to change ted Accessories Tin-p la Finger guards from p. 242 35 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Representatives Max. Max. 33 m /h DC axial fans 3 60 x 15 mm Housing: GRP1) (PBT) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Counterclockwise, looking towards rotor Connection: Via single wires AWG 28, TR 64 Highlights: Some models are suitable for use at high ambient temperatures Weight: 30 g – Material: – – – – – – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - PWM control input - Moisture protection Hours 4 000 -20...+50 50 000 / 20 000 52 500 0.4 2 650 -20...+70 50 000 / 20 000 52 500 4.4 1.0 3 900 -20...+70 50 000 / 20 000 52 500 4.8 1.5 4 500 -20...+60 45 000 / 17 500 47 500 27 4.4 1.1 3 900 -20...+70 50 000 / 20 000 52 500 16...28 31 4.8 1.4 4 500 -20...+60 45 000 / 17 500 47 500 Air flow Nominal voltage Voltage range m3/h cfm VDC VDC 605 F 29 17.1 5 4.5...5.2 27 4.4 1.1 612 FL 19 11.2 12 11.5...13.2 16 3.6 612 F 29 17.1 12 10.8...13.2 27 612 FH 33 19.4 12 10.0...13.2 31 614 F 29 17.1 24 21.6...26.4 614 F/39 H-691 33 19.4 24 dB(A) Bel(A) Hours Model with temperature range up to +80 / 85 °C. 612 FL-680 19 11.2 12 11.5...14 16 3.6 0.5 2 650 -20...+85 50 000 / 20 000 52 500 612 F-637 29 17.1 12 10.8...12.6 27 4.4 1.0 3 900 -20...+80 50 000 / 20 000 52 500 Subject to change Tin-p la 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 36 Finger guards from p. 242 ted Curve Life expectancy L10IPC (40 °C) see page 17 Service life L10 (60 °C) ebm-papst standard °C Type Nominal data Service life L10 (20 °C) ebm-papst standard rpm-1 Sound power level Temperature range Power consumption Watts Nominal speed Sintec sleeve bearings Ball bearings / Air flow Series 600 F Sound pressure level 1) Fiberglass-reinforced plastic ¡ ¿ ¡ ¬ ¡ ¬ ¿ ¡ Information 67 m /h DC axial fans 3 60 x 25 mm – – – DC axial fans – – – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - Alarm with speed limit - External temperature sensor - Internal temperature sensor - PWM control input - Analog control input - Moisture protection DC centrifugal fans Housing: GRP1) (PBT) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Clockwise, looking towards rotor Connection: Via single wires AWG 22, TR 64 Highlights: Very low-noise motor Weight: 85 g – Material: Hours Hours 622 L 21 12.4 12 8...15 20 3.7 0.5 3 200 -20...+85 80 000 / 20 000 135 000 622 M 30 17.7 12 8...15 29 4.3 1.0 4 550 -20...+75 77 500 / 30 000 130 000 622 N 40 23.5 12 8...15 35 4.7 1.9 6 100 -20...+70 72 500 / 35 000 122 500 622 H 46 27.1 12 8...15 39 5.1 2.3 6 850 -20...+70 70 000 / 35 000 117 500 622 HH 56 33.0 12 8...15 43 5.6 3.5 8 200 -20...+70 65 000 / 32 500 110 000 622/2 H3P 67 39.4 12 8...13.2 48 5.9 5.5 9 700 -20...+60 52 500 / 32 500 87 500 624 L 21 12.4 24 18...28 20 3.7 1.0 3 200 -20...+70 80 000 / 40 000 135 000 624 M 30 17.7 24 12...28 29 4.3 1.5 4 550 -20...+70 77 500 / 37 500 130 000 624 N 40 23.5 24 12...28 35 4.7 2.2 6 100 -20...+70 72 500 / 35 000 122 500 624 H 46 27.1 24 18...28 39 5.1 2.4 6 850 -20...+70 70 000 / 35 000 117 500 624 HH 56 33.0 24 18...28 43 5.6 3.6 8 200 -20...+70 65 000 / 32 500 110 000 624/2 H3P 67 39.4 24 18...28 48 5.9 5.6 9 700 -20...+60 52 500 / 32 500 87 500 628 HH 56 33.0 48 36...60 43 5.6 4.2 8 200 -20...+70 65 000 / 32 500 110 000 DC fans - specials °C ¿ ¡ ¬ √ ƒ ≈ ACmaxx / EC fans rpm-1 ¿ ¡ ¬ √ ƒ ≈ AC axial fans Watts Curve Power consumption / Life expectancy L10IPC (40 °C) see page 17 Sintec sleeve bearings Ball bearings Bel(A) Service life L10 (Tmax) ebm-papst standard Sound power level dB(A) Air flow m3/hcfm VDC Service life L10 (40 °C) ebm-papst standard Sound pressure level Type Air flow Nominal data Temperature range Voltage range VDC Series 620 Nominal speed Nominal voltage 1) Fiberglass-reinforced plastic ƒ AC centrifugal fans Subject to change ted Accessories Tin-p la Finger guards from p. 242 37 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Representatives Max. Max. 58 m /h DC axial fans 3 60 x 25 mm – Possible special versions: Housing: GRP1) (PBT) (See chapter DC fans - specials) Impeller: GRP1) (PA) - Speed signal Direction of air flow: Exhaust over struts - Go / NoGo alarm Direction of rotation: Clockwise, - Alarm with speed limit looking towards rotor - External temperature sensor Connection: Via single wires AWG 22, - PWM control input TR 64 - Analog control input Highlights: Developed for applications with - Moisture protection demanding environmental - Salt spray protection requirements - Degree of protection: IP 54 / IP 68 Weight: 70 g – Material: – – – – – 5 900 -20...+70 85 000 / 42 500 142 500 6 300 -20...+70 85 000 / 42 500 142 500 1.6 5 900 -20...+70 85 000 / 42 500 142 500 3.2 8 500 -20...+70 75 000 / 37 500 127 500 6.1 3.2 8 500 -20...+70 75 000 / 37 500 127 500 5.4 1.8 6 300 -20...+70 85 000 / 42 500 142 500 Air flow Nominal voltage Voltage range VDC 632 NU 40 23.5 12 6...15 33 5.2 1.8 632/2 HPU 44 25.9 12 10.8...13.2 35 5.4 1.5 634 NU 40 23.5 24 12...30 34 5.1 634 HHU 58 34.1 24 18...28 44 6.1 634/2 HHPU 58 34.1 24 18...28 44 638/2 HPU 44 25.9 48 40...60 35 dB(A) Bel(A) Subject to change Tin-p la 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Finger guards from p. 242 ted Curve Hours VDC 38 Life expectancy L10IPC (40 °C) see page 17 Hours cfm Type Service life L10 (Tmax) ebm-papst standard °C m3/h Nominal data Service life L10 (40 °C) ebm-papst standard rpm-1 Sound power level Temperature range Power consumption Watts Nominal speed Sintec sleeve bearings Ball bearings / Air flow Series 630 Sound pressure level 1) Fiberglass-reinforced plastic ¿ ¡ ¿ ¬ ¬ ¡ Information DC axial fans 3 60 x 25 mm – – – – – – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - Moisture protection - Degree of protection: IP 54 / IP 68 DC centrifugal fans Housing: GRP1) (PBT) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Clockwise, looking towards rotor Connection: Via single wires AWG 22, TR 64 Highlights: Some models are suitable for use at high ambient temperatures up to 85 °C. Weight: 66 g – Material: 612 NGLE 21 12.4 12 8...15 16 3.6 0.6 2 500 -20...+85 80 000 / 27 500 135 000 612 NLE 21 12.4 12 8...15 16 3.6 0.4 2 500 -20...+85 80 000 / 27 500 135 000 612 NGMLE 25 14.7 12 8...15 19 3.9 0.7 3 000 -20...+80 80 000 / 32 500 135 000 612 NMLE 25 14.7 12 8...15 19 3.9 0.4 3 000 -20...+85 80 000 / 27 500 135 000 612 NGME 35 20.6 12 8...15 28 4.6 1.2 4 100 -20...+75 80 000 / 35 000 135 000 612 NME 35 20.6 12 8...15 28 4.6 0.8 4 100 -20...+75 80 000 / 35 000 135 000 612 NN 42 24.7 12 8...15 35 5.0 1.5 5 100 -20...+70 70 000 / 35 000 117 500 612 NH 43 25.3 12 8...15 37 5.3 1.8 5 600 -20...+70 70 000 / 35 000 117 500 612 NHH-118 56 33.0 12 8...15 41 5.7 2.9 6 800 -20...+70 60 000 / 30 000 102 500 614 NGL 21 12.4 24 18...28 16 3.6 1.0 2 500 -20...+70 80 000 / 40 000 135 000 614 NL 21 12.4 24 18...28 16 3.6 0.8 2 500 -20...+70 80 000 / 40 000 135 000 614 NGML 25 14.7 24 18...28 19 3.9 1.2 3 000 -20...+70 80 000 / 40 000 135 000 614 NML 25 14.7 24 18...28 19 3.9 1.0 3 000 -20...+70 80 000 / 40 000 135 000 614 NGM 35 20.6 24 18...28 28 4.6 1.7 4 100 -20...+70 80 000 / 40 000 135 000 614 NM 35 20.6 24 18...28 28 4.6 1.3 4 100 -20...+70 80 000 / 40 000 135 000 614 NN 42 24.7 24 18...28 35 5.0 1.8 5 100 -20...+70 70 000 / 35 000 117 500 614 NH 43 25.3 24 18...26 37 5.3 2.1 5 600 -20...+70 70 000 / 35 000 117 500 614 NHH 56 33.0 24 18...26 41 5.7 2.9 6 850 -20...+70 60 000 / 30 000 102 500 614 NHH-119 56 33.0 24 18...28 41 5.7 2.9 6 850 -20...+70 60 000 / 30 000 102 500 618 NM 35 20.6 48 36...56 28 4.6 1.9 4 100 -20...+70 80 000 / 40 000 135 000 618 NN 42 24.7 48 36...56 35 5.0 2.1 5 100 -20...+65 70 000 / 40 000 117 500 Tin-p la Hours Hours ¿ ¿ ¡ ¡ ¬ ¬ √ ƒ ≈ ¿ ¿ ¡ ¡ ¬ ¬ √ ƒ ≈ ≈ ¬ √ ted Accessories dB(A) Bel(A) DC fans - specials VDC ACmaxx / EC fans VDC AC axial fans cfm Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Finger guards from p. 242 39 2016-01 Type AC centrifugal fans m3/h Nominal data Curve Life expectancy L10IPC (40 °C) see page 17 Service life L10 (Tmax) ebm-papst standard Service life L10 (40 °C) ebm-papst standard Temperature range Power consumption Nominal speed Sintec sleeve bearings Ball bearings Sound power level °C Voltage range rpm-1 Nominal voltage Watts Air flow / Air flow Sound pressure level 1) Fiberglass-reinforced plastic Series 600 N DC axial fans 56 m /h Representatives Max. Max. 41 m /h DC axial fans 3 60 x 25 mm Housing: GRP1) (PBT) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Clockwise, looking towards rotor Connection: Via single wires AWG 22, TR 64 Highlights: Automatic speed adjustment with temperature sensor Weight: 66 g – Material: – – – – – – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - External temperature sensor - Internal temperature sensor - Moisture protection 30°C 612 NMI 55°C 30°C 612 NGNI 55°C 30°C 612 NNI 55°C 30°C 612 NGNV 55°C 18 10.6 35 20.6 16 9.4 35 20.6 23 13.5 41 24.1 23 13.5 41 24.1 23 13.5 41 24.1 12 8...12.6 12 8...12.6 12 8...12.6 12 8...12.6 12 8...12.6 dB(A) Bel(A) rpm-1 °C Hours Hours -20...+65 80 000 / 45 000 135 000 -20...+65 80 000 / 45 000 135 000 -20...+65 70 000 / 40 000 117 500 -20...+65 70 000 / 40 000 117 500 -20...+65 70 000 / 40 000 117 500 14 3.5 1.3 2 150 28 4.6 1.7 4 100 16 3.6 1.0 2 400 28 4.6 1.4 4 100 18 3.8 1.7 2 900 35 5.0 2.4 5 100 18 3.8 1.2 2 900 35 5.0 1.5 5 100 18 3.8 1.7 2 900 35 5.0 2.4 5 100 Curve Life expectancy L10IPC (40 °C) see page 17 Watts Service life L10 (Tmax) ebm-papst standard / Service life L10 (40 °C) ebm-papst standard Power consumption VDC Sintec sleeve bearings Ball bearings VDC Sound power level Voltage range cfm Temperature range 612 NGMI 55°C m3/h Nominal speed 30°C Nominal voltage Type Air flow Nominal data Air flow Series 600 N VARIOFAN Sound pressure level 1) Fiberglass-reinforced plastic ¿ ¡ ¬ √ ƒ ≈ ƒ ≈ ƒ ≈ Subject to change Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on half-sphere of 2 m; Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/ general conditions V types I types Tin-p la 2016-01 The temperature sensor for controlling the motor speed is not included in the scope of delivery. For the temperature sensor LZ 370, see accessories. 40 Finger guards from p. 242 The temperature sensor (NTC resistor) for controlling the motor speed is positioned in the fan hub directly in the air flow. ted Information 82 m /h DC axial fans 3 60 x 32 mm – – DC axial fans – – – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - Alarm with speed limit - External temperature sensor - PWM control input - Analog control input - Moisture protection DC centrifugal fans Housing: GRP1) (PBT) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Clockwise, looking towards rotor Connection: Via single wires AWG 24, TR 64 Weight: 100 g – Material: -20...+70 57 500 / 27 500 97 500 7.7 11 700 -20...+70 57 500 / 27 500 97 500 6.4 7.7 11 700 -20...+70 57 500 / 27 500 97 500 ¿ ¡ Nominal voltage Voltage range 612 JH 70 41.1 12 7...13.6 53 6.4 7.7 614 JH 70 41.1 24 14...26.4 53 6.4 618 JH 70 41.1 48 36...56 53 dB(A) Bel(A) Hours Fan types with streamer and integrated guard grille. 614 J/2 HHP 82 48.3 24 18...30 62 7.6 14.6 15 000 -20...+75 65 000 / 25 000 110 000 618 J/2 HHP 82 48.3 48 38...58 62 7.6 14.6 15 000 -20...+75 65 000 / 25 000 110 000 DC fans - specials Air flow VDC Curve 11 700 VDC ¿ ¿ ACmaxx / EC fans Life expectancy L10IPC (40 °C) see page 17 Hours cfm Type Service life L10 (Tmax) ebm-papst standard °C m3/h Nominal data Service life L10 (40 °C) ebm-papst standard rpm-1 Sound power level Temperature range Power consumption Watts Nominal speed Sintec sleeve bearings Ball bearings / Air flow Series 600 J Sound pressure level 1) Fiberglass-reinforced plastic ¡ Subject to change AC centrifugal fans AC axial fans Rear view of types 614 J/2HHP and 618 J/2HHP ted Accessories Tin-p la Finger guards from p. 242 41 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Representatives Max. Max. 44 m /h DC axial fans 3 70 x 15 mm Housing: GRP1) (PBT) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Counterclockwise, looking towards rotor Connection: Via single wires AWG 24 to AWG 28, TR 64 Weight: 53 g – Material: – – – – – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - Moisture protection -20...+70 60 000 / 30 000 102 500 4 300 -20...+70 60 000 / 30 000 102 500 1.7 5 300 -20...+70 60 000 / 30 000 102 500 1.5 5 300 -20...+70 60 000 / 30 000 102 500 VDC 712 F/2L-005* 28 16.5 12 8...13.8 25 4.7 0.6 712 F/2M-006* 36 21.2 12 8...13.8 32 5.0 1.1 712 F 44 25.9 12 8...13.8 38 5.3 714 F 44 25.9 24 18...28 5.3 38 Subject to change *Version with 3-pin Molex plug housing Molex Contacts 22-01-2035 08-50-0113 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 42 Finger guards from p. 242 Tin-p la ted Curve 3 300 VDC dB(A) Bel(A) Life expectancy L10IPC (40 °C) see page 17 Hours cfm Type Service life L10 (Tmax) ebm-papst standard Hours m3/h Nominal data Service life L10 (40 °C) ebm-papst standard Temperature range Power consumption °C Voltage range rpm-1 Nominal voltage Nominal speed Sintec sleeve bearings Ball bearings Watts Air flow Sound power level / Air flow Series 700 F Sound pressure level 1) Fiberglass-reinforced plastic ¿ ¡ ¬ ¬ Information 117 m /h DC axial fans 3 80 x 25 mm – – – DC axial fans – – – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - Alarm with speed limit - External temperature sensor - Internal temperature sensor - PWM control input - Analog control input - Moisture protection DC centrifugal fans Housing: GRP1) (PBT) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Counterclockwise, looking towards rotor Connection: Via single wires AWG 24, TR 64 Highlights: Very low-noise motor Weight: 105 g – Material: 135 000 80 000 / 35 000 135 000 1.8 3 600 -20...70 70 000 / 35 000 117 500 32 18.8 12 8...15 14 3.3 0.4 8452 GM 58 34.1 12 8...15 32 4.7 1.3 8452 GN 68 40.0 12 8...15 36 5.0 Models with 25 kHz PWM control and speed signal to 4-wire specification (see page 179). ¿ ¡ ¬ 8452/2 GHP 75 44.1 12 10.8...13.2 38 5.3 2.5 4 000 -20...70 70 000 / 35 000 117 500 8452/2 GHHP 83 48.8 12 10.8...13.2 42 5.5 3.5 4 400 -20...60 65 000 / 40 000 110 000 √ ƒ ≈ Models with 1-30 kHz PWM control and speed signal. 8452/2 H4P 117 68.8 12 8...15 50 6.4 6.8 6 200 -20...70 60 000 / 30 000 102 500 8454/2 H4P 117 68.8 24 20.0...26.4 50 6.4 6.8 6 200 -20...70 60 000 / 30 000 102 500 DC fans - specials 80 000 / 35 000 -20...75 8452 GL ACmaxx / EC fans -20...75 3 100 VDC Curve 1 700 VDC dB(A) Bel(A) Life expectancy L10IPC (40 °C) see page 17 Hours cfm Type Service life L10 (Tmax) ebm-papst standard Hours m3/h Nominal data Service life L10 (40 °C) ebm-papst standard Temperature range Power consumption °C Voltage range rpm-1 Nominal voltage Nominal speed Sintec sleeve bearings Ball bearings Watts Air flow Sound power level / Air flow Series 8450 Sound pressure level 1) Fiberglass-reinforced plastic ≈ AC centrifugal fans AC axial fans Subject to change ted Accessories Tin-p la Finger guards from p. 242 43 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Representatives Max. Max. 79 m /h DC axial fans 3 80 x 25 mm Housing: GRP1) (PBT) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Counterclockwise, looking towards rotor Connection: Via single wires AWG 24, TR 64 Highlights: Some models are suitable for use at high ambient temperatures up to 85 °C. Weight: 95 g – Material: – – – – – – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - Alarm with speed limit - External temperature sensor - Internal temperature sensor - PWM control input - Analog control input - Moisture protection - Degree of protection: IP 54 / IP 68 cfm VDC VDC 8412 NGLE 33 19.4 12 8...15 12 3.5 0.5 1 500 -20...+85 80 000 / 27 500 135 000 8412 NLE 33 19.4 12 8...15 17 3.7 0.3 1 500 -20...+85 80 000 / 27 500 135 000 8412 NGMLE 45 26.5 12 8...15 19 3.9 0.9 2 050 -20...+80 80 000 / 32 500 135 000 8412 NMLE 45 26.5 12 8...15 21 4.0 0.6 2 050 -20...+85 80 000 / 27 500 135 000 8412 NGME 58 34.1 12 8...15 26 4.3 1.4 2 600 -20...+75 80 000 / 35 000 135 000 8412 NME 58 34.1 12 8...15 27 4.4 1.0 2 600 -20...+75 80 000 / 35 000 135 000 8412 NG 69 40.6 12 8...15 32 4.7 2.0 3 100 -20...+70 70 000 / 35 000 117 500 8412 N 69 40.6 12 8...15 32 4.7 1.7 3 100 -20...+70 70 000 / 35 000 117 500 8412 NH 79 46.5 12 8...13.2 37 5.0 2.1 3 600 -20...+70 70 000 / 35 000 117 500 8412 NH-217 79 46.5 12 8...15 37 5.0 2.5 3 600 -20...+70 70 000 / 35 000 117 500 8414 NGL 33 19.4 24 18...28 12 3.5 0.9 1 500 -20...+70 80 000 / 40 000 135 000 8414 NL 33 19.4 24 18...28 17 3.7 0.8 1 500 -20...+70 80 000 / 40 000 135 000 8414 NGML 45 26.5 24 18...28 19 3.9 1.2 2 050 -20...+70 80 000 / 40 000 135 000 8414 NML 45 26.5 24 18...28 21 4.0 1.1 2 050 -20...+70 80 000 / 40 000 135 000 8414 NGM 58 34.1 24 18...28 26 4.3 1.4 2 600 -20...+70 80 000 / 40 000 135 000 8414 NM 58 34.1 24 18...28 27 4.4 1.4 2 600 -20...+70 80 000 / 40 000 135 000 8414 NG 69 40.6 24 18...28 32 4.7 2.2 3 100 -20...+70 70 000 / 35 000 117 500 8414 N 69 40.6 24 18...28 32 4.7 1.8 3 100 -20...+70 70 000 / 35 000 117 500 8414 NH 79 46.5 24 18...26 37 5.0 2.4 3 600 -20...+70 70 000 / 35 000 117 500 8414 NH-221 79 46.5 24 18...28 37 5.0 2.2 3 600 -20...+70 70 000 / 35 000 117 500 8418 N 69 40.6 48 36...56 32 4.7 2.0 3 100 -20...+70 70 000 / 35 000 117 500 Type dB(A) Bel(A) Tin-p la Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 44 Finger guards from p. 242 ted Hours Hours Curve Life expectancy L10IPC (40 °C) see page 17 Service life L10 (Tmax) ebm-papst standard m3/h Nominal data 2016-01 Service life L10 (40 °C) ebm-papst standard Temperature range Power consumption Nominal speed Sintec sleeve bearings Ball bearings Sound power level °C Voltage range rpm-1 Nominal voltage Watts Air flow / Air flow Series 8400 N Sound pressure level 1) Fiberglass-reinforced plastic ¿ ¿ ¡ ¡ ¬ ¬ √ √ ƒ ƒ ¿ ¿ ¡ ¡ ¬ ¬ √ √ ƒ ƒ √ Information 58 m /h DC axial fans 3 80 x 25 mm – – – – – – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - External temperature sensor - Internal temperature sensor - Moisture protection DC axial fans Housing: GRP1) (PBT) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Counterclockwise, looking towards rotor Connection: Via single wires AWG 24, TR 64 Highlights: Automatic speed adjustment with temperature sensor Weight: 95 g – Material: DC centrifugal fans Max. 15.9 26.6 35 20.6 58 34.1 12 8...14 12 8...14 °C Hours Hours -20...+65 80 000 / 45 000 135 000 -20...+65 80 000 / 45 000 135 000 -20...+65 80 000 / 45 000 135 000 < 10 <3 0.9 900 12 3.5 1.1 1 500 < 10 3.0 1.1 1 200 19 3.9 1.5 2 050 < 13 3.5 1.4 1 600 26 4.3 2.0 2 600 Curve Life expectancy L10IPC (40 °C) see page 17 Service life L10 (Tmax) ebm-papst standard Power consumption Service life L10 (40 °C) ebm-papst standard Sintec sleeve bearings Ball bearings rpm-1 DC fans - specials 10...14 Sound power level Voltage range 27 45 12 Watts ¿ ¡ ¬ √ ACmaxx / EC fans 8412 NGMI 11.8 19.4 / ƒ ≈ AC axial fans Subject to change AC centrifugal fans 50°C 20 33 dB(A) Bel(A) Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on half-sphere of 2 m; Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions V types I types Tin-p la ted Accessories 30°C 8412 NGMLV VDC The temperature sensor for controlling the motor speed is not included in the scope of delivery. For the temperature sensor LZ 370, see accessories. Finger guards from p. 242 The temperature sensor (NTC resistor) for controlling the motor speed is positioned in the fan hub directly in the air flow. 45 Representatives 50°C VDC 2016-01 30°C 8412 NGLV cfm Temperature range 50°C m3/h Nominal speed 30°C Nominal voltage Type Air flow Nominal data Air flow Series 8400 N VARIOFAN Sound pressure level 1) Fiberglass-reinforced plastic Max. 80 m /h DC axial fans 3 80 x 32 mm Housing: GRP1) (PBT) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Clockwise, looking towards rotor Connection: Via single wires AWG 22, TR 64 Weight: 170 g – Material: – – – – – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - Alarm with speed limit - External temperature sensor - Internal temperature sensor - PWM control input - Analog control input - Moisture protection - Salt spray protection - Degree of protection: IP 54 / IP 68 dB(A) Bel(A) °C Hours Hours 8312 L 32 18.8 12 6...15 24 4.0 1.2 2 000 -20...+75 80 000 / 32 500 135 000 8312 M 48 28.3 12 6...15 34 5.0 2.2 3 000 -20...+75 70 000 / 27 500 117 500 8312 54 31.8 12 6...15 36 5.2 2.6 3 300 -20...+75 70 000 / 27 500 117 500 8312 HL 67 39.4 12 6...15 43 5.8 4.0 4 200 -20...+75 62 500 / 25 000 105 000 8312 H 80 47.1 12 6...12.6 48 6.2 6.4 5 000 -20...+60 55 000 / 35 000 92 500 8314 L 32 18.8 24 12...31.5 24 4.0 1.0 2 000 -20...+75 80 000 / 32 500 135 000 8314 M 48 28.3 24 12...31.5 34 5.0 2.3 3 000 -20...+75 70 000 / 27 500 117 500 8314 54 31.8 24 12...31.5 36 5.2 2.7 3 300 -20...+75 70 000 / 27 500 117 500 8314 HL 67 39.4 24 12...31.5 43 5.8 4.3 4 200 -20...+75 62 500 / 25 000 105 000 8314 H 80 47.1 24 12...28 48 6.2 6.0 5 000 -20...+75 55 000 / 20 000 92 500 8318 54 31.8 48 36...60 36 5.2 3.0 3 300 -20...+75 70 000 / 27 500 117 500 8318 HL 67 39.4 48 36...60 43 5.8 4.2 4 200 -20...+75 62 500 / 25 000 105 000 8318 H 80 47.1 48 36...60 48 6.2 6.2 5 000 -20...+65 55 000 / 30 000 92 500 Rotor protrusion max. 0.4 mm. Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 46 Finger guards from p. 242 Tin-p la ted Curve rpm-1 Subject to change 2016-01 Life expectancy L10IPC (40 °C) see page 17 Service life L10 (Tmax) ebm-papst standard Watts Service life L10 (40 °C) ebm-papst standard / Temperature range VDC Nominal speed VDC Power consumption cfm Sintec sleeve bearings Ball bearings Voltage range m3/h Sound power level Nominal voltage Type Air flow Nominal data Air flow Series 8300 Sound pressure level 1) Fiberglass-reinforced plastic ¿ ¡ ¬ √ ƒ ¿ ¡ ¬ √ ƒ ¬ √ ƒ Information 222 m /h DC axial fans 3 80 x 38 mm – – – – – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - Alarm with speed limit - External temperature sensor - Internal temperature sensor - PWM control input - Analog control input - Moisture protection - Degree of protection:IP 54 DC axial fans Housing: GRP1) (PBT) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Counterclockwise, looking towards rotor Connection: Via single wires AWG 24 (H3 and H4: AWG 22), TR 64 Weight: 160 g (H3 and H4: 200 g) – Material: DC centrifugal fans Max. Hours 8212 JN 132 78 12 7...13.8 55 6.6 10 8 400 -20...+70 62 500 / 32 500 105 000 8212 JH3 190 112 12 6...13.8 66 7.3 26* 12 000 -20...+70 55 000 / 27 500 92 500 8212 JH4 222 131 12 6...13.8 71 7.8 39* 14 000 -20...+70 50 000 / 25 000 85 000 8214 JN 132 78 24 18...26.4 55 6.6 11 8 400 -20...+70 62 500 / 32 500 105 000 8214 JH3 190 112 24 12...27.6 66 7.3 26* 12 000 -20...+70 55 000 / 27 500 92 500 8214 JH4 222 131 24 12...27.6 71 7.8 38* 14 000 -20...+70 50 000 / 25 000 85 000 8218 JN 132 78 48 36...53 55 6.6 11 8 400 -20...+70 62 500 / 32 500 105 000 8218 JH3 190 112 48 36...53 66 7.3 25* 12 000 -20...+70 55 000 / 27 500 92 500 8218 JH4 222 131 48 20...58 71 7.8 36* 14 000 -20...+70 50 000 / 25 000 85 000 DC fans - specials Hours Curve °C Life expectancy L10IPC (40 °C) see page 17 rpm-1 Service life L10 (Tmax) ebm-papst standard Watts Service life L10 (40 °C) ebm-papst standard / ¿ ¡ ¬ ¿ ¡ ¬ ACmaxx / EC fans dB(A) Bel(A) Temperature range VDC Nominal speed VDC Power consumption cfm Sintec sleeve bearings Ball bearings Voltage range m3/h Sound power level Nominal voltage Type Air flow Nominal data Air flow Series 8200 J Sound pressure level 1) Fiberglass-reinforced plastic ¿ ¡ ¬ Subject to change ted 47 Representatives Finger guards from p. 242 Tin-p la 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Accessories AC centrifugal fans AC axial fans 8200 JH3 and JH4 also available as standard with PWM control input and speed signal. Speed control range from 2000 rpm-1 up to maximum nominal speed. Standstill at 0% PWM, maximum speed if control cable is interrupted. * Power consumption at free air flow. These values can be significantly higher in the operating point. Max. 102 m /h DC axial fans 3 92 x 25 mm Housing: GRP1) (PBT) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Counterclockwise, looking towards rotor Connection: Via single wires AWG 24, TR 64 Weight: 100 g – Material: – – – – – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - Alarm with speed limit - External temperature sensor - Internal temperature sensor - PWM control input - Analog control input - Moisture protection - Degree of protection: IP 54 / IP 68 -20...+80 -20...+85 -20...+75 -20...+75 -20...+70 -20...+70 -20...+70 -20...+70 -20...+60 -20...+60 -20...+70 80 000 / 22 500 80 000 / 17 500 75 000 / 27 500 75 000 / 27 500 70 000 / 35 000 70 000 / 35 000 70 000 / 35 000 70 000 / 35 000 70 000 / 45 000 70 000 / 45 000 70 000 / 35 000 135 000 135 000 127 500 127 500 117 500 117 500 117 500 117 500 117 500 117 500 117 500 1.4 1.1 1.7 1.4 2.5 2.1 3.0 2.3 3.2 3.2 3.1 3.2 1 950 1 950 2 300 2 300 2 700 2 700 3 000 3 000 3 250 3 250 3 250 3 250 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 80 000 / 40 000 80 000 / 40 000 75 000 / 37 500 75 000 / 37 500 70 000 / 35 000 70 000 / 35 000 70 000 / 35 000 70 000 / 35 000 70 000 / 35 000 70 000 / 35 000 70 000 / 35 000 70 000 / 35 000 135 000 135 000 127 500 127 500 117 500 117 500 117 500 117 500 117 500 117 500 117 500 117 500 2.4 2 700 -20...+70 70 000 / 35 000 117 500 VDC VDC 3412 NGLE 3412 NLE 3412 NGME 3412 NME 3412 NG 3412 N 3412 NGH 3412 NH 3412 NGHH 3412 NHH 3412 NHH-379 61 61 72 72 84 84 94 94 102 102 102 35.9 35.9 42.4 42.4 49.4 49.4 55.3 55.3 60.0 60.0 60.0 12 12 12 12 12 12 12 12 12 12 12 8...15 8...15 8...15 8...15 8...15 8...15 8...15 8...15 8...13.2 8...13.2 8...15 23 23 28 28 32 32 36 36 39 39 39 4.0 4.0 4.3 4.3 4.7 4.7 5.0 5.0 5.1 5.1 5.1 1.1 0.8 1.6 1.1 1.9 1.7 2.3 2.1 3.2 2.9 2.7 3414 NGL 3414 NL 3414 NGM 3414 NM 3414 NG 3414 N 3414 NGH 3414 NH 3414 NGHH 3414 NGHH-389 3414 NHH 3414 NHH-386 61 61 72 72 84 84 94 94 102 102 102 102 35.9 35.9 42.4 42.4 49.4 49.4 55.3 55.3 60.0 60.0 60.0 60.0 24 24 24 24 24 24 24 24 24 24 24 24 18...28 18...28 18...28 18...28 18...28 18...28 18...26 18...26 18...26 18...28 18...26 18...28 23 23 28 28 32 32 36 36 39 39 39 39 4.0 4.0 4.3 4.3 4.7 4.7 5.0 5.0 5.1 5.1 5.1 5.1 84 49.4 48 36...56 32 4.7 Other 48 VDC models on request. Tin-p la 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 48 Finger guards from p. 242 ted Curve 1 950 1 950 2 300 2 300 2 700 2 700 3 000 3 000 3 250 3 250 3 250 cfm 3418 N Life expectancy L10IPC (40 °C) see page 17 Hours m3/h dB(A) Bel(A) Service life L10 (Tmax) ebm-papst standard Hours Type Nominal data Service life L10 (40 °C) ebm-papst standard Temperature range Power consumption °C Voltage range rpm-1 Nominal voltage Nominal speed Sintec sleeve bearings Ball bearings Watts Air flow Sound power level / Air flow Series 3400 N Sound pressure level 1) Fiberglass-reinforced plastic ¿ ¿ ¡ ¡ ¬ ¬ √ √ ƒ ƒ ƒ ¿ ¿ ¡ ¡ ¬ ¬ √ √ ƒ ƒ ƒ ƒ ¬ Information 84 m /h DC axial fans 3 92 x 25 mm – – – DC axial fans – – – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - External temperature sensor - Internal temperature sensor - Moisture protection DC centrifugal fans Housing: GRP1) (PBT) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Counterclockwise, looking towards rotor Connection: Via single wires AWG 24, TR 64 Highlights: Automatic speed adjustment with temperature sensor Weight: 100 g – Material: 25.9 42.4 50 29.4 84 49.4 rpm-1 °C Hours Hours -20...+65 75 000 / 42 500 127 500 -20...+65 75 000 / 42 500 127 500 14 3.5 1.5 1 400 28 4.3 2.0 2 300 16 3.7 1.6 1 600 32 4.7 2.5 2 700 Curve Life expectancy L10IPC (40 °C) see page 17 Service life L10 (Tmax) ebm-papst standard Watts Service life L10 (40 °C) ebm-papst standard 8...12.6 Power consumption 12 Sintec sleeve bearings Ball bearings 8...14 Sound power level 12 / DC fans - specials 44 72 dB(A) Bel(A) ¿ ¡ ¬ √ ACmaxx / EC fans 3412 NGV VDC AC axial fans Subject to change AC centrifugal fans The temperature sensor for controlling the motor speed is not included in the scope of delivery. For the temperature sensor LZ 370, see accessories. ted Accessories Tin-p la Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Finger guards from p. 242 49 2016-01 50°C VDC Temperature range 30°C 3412 NGMV cfm Nominal speed 50°C Voltage range 30°C m3/h Nominal voltage Type Air flow Nominal data Air flow Series 3400 N VARIOFAN Sound pressure level 1) Fiberglass-reinforced plastic Representatives Max. Max. DC axial fans 133 m /h 3 92 x 32 mm Housing: GRP1) (PBT) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Clockwise, looking towards rotor Connection: Via single wires AWG 24 UL 1061, TR 64 Weight: 190 g – Material: – – – – – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - External temperature sensor - Internal temperature sensor - PWM control input - Analog control input - Moisture protection - Salt spray protection - Degree of protection: IP 54 / IP 68 dB(A) Bel(A) rpm-1 °C Hours Hours 3312 NL 56 33 12 6...15 24 4.1 0.8 1 850 -20...+75 80 000 / 35 000 135 000 3312 NM 68 40 12 6...15 29 4.5 1.3 2 250 -20...+75 70 000 / 30 000 117 500 3312 NN 80 47 12 6...15 35 4.7 1.8 2 650 -20...+75 70 000 / 30 000 117 500 3312 NH 93 54 12 6...15 38 5.1 2.8 3 050 -20...+75 65 000 / 27 500 110 000 3312 NHH 107 63 12 6...15 42 5.4 3.4 3 450 -20...+75 57 500 / 25 000 97 500 3312 NH3 133 78 12 6...14 50 6.0 6.7 4 350 -20...+70 50 000 / 25 000 85 000 3314 NN 80 47 24 18...28 35 4.7 1.8 2 650 -20...+75 70 000 / 30 000 117 500 3314 NH 93 54 24 18...28 38 5.1 2.6 3 050 -20...+75 65 000 / 27 500 110 000 3314 NHH 107 63 24 18...28 42 5.4 3.5 3 450 -20...+75 57 500 / 25 000 97 500 3314 NH3 133 78 24 18...28 50 6.0 6.7 4 350 -20...+75 50 000 / 22 500 85 000 3318 NN 80 47 48 36...60 35 4.7 1.8 2 650 -20...+75 70 000 / 30 000 117 500 3318 NH 93 54 48 36...60 38 5.1 3.5 3 050 -20...+75 65 000 / 27 500 110 000 3318 NH3 133 78 48 36...58 50 6.0 6.5 4 350 -20...+75 50 000 / 22 500 85 000 Curve Life expectancy L10IPC (40 °C) see page 17 Service life L10 (Tmax) ebm-papst standard Watts Service life L10 (40 °C) ebm-papst standard / Temperature range VDC Nominal speed VDC Power consumption cfm Sintec sleeve bearings Ball bearings Voltage range m3/h Sound power level Nominal voltage Type Air flow Nominal data Air flow Series 3300 N Sound pressure level 1) Fiberglass-reinforced plastic ¿ ¡ ¬ √ ƒ ≈ ¬ √ ƒ ≈ ¬ √ ≈ Subject to change Tin-plated 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 50 Finger guards from p. 242 Ø 100,1 ± 0,3 Information 92 x 38 mm Housing: GRP1) (PBT) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Clockwise, looking towards rotor Connection: Via single wires AWG 24 (H3 and H4: AWG 22), TR 64 Weight: 240 g (H3 and H4: 280 g) – Material: – – – – – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - Alarm with speed limit - External temperature sensor - Internal temperature sensor - PWM control input - Analog control input - Moisture protection - Degree of protection: IP 54 / IP 68 VDC VDC 3212 JN 130 76.5 12 7...13.8 51 6.1 7.5 6 000 -20 ...+70 70 000 / 35 000 117 500 3212 JH 146 86.0 12 7...15 55 6.4 9.0 6 800 -20 ...+70 70 000 / 35 000 117 500 3212 JH3 237 139.5 12 6...13.8 69 7.8 31.0* 11 000 -20 ...+70 65 000 / 32 500 110 000 3212 JH4 280 164.8 12 6...13.8 73 8.2 50.0* 13 000 -20 ...+70 60 000 / 30 000 110 000 3214 JN 130 76.5 24 11...28 51 6.1 6.5 6 000 -20 ...+70 70 000 / 35 000 117 500 3214 JH 146 86.0 24 12...30 55 6.4 9.0 6 800 -20 ...+70 70 000 / 35 000 117 500 3214 JH3 237 139.5 24 12...27.6 69 7.8 30.0* 11 000 -20 ...+70 65 000 / 32 500 110 000 3214 JH4 280 164.8 24 12...27.6 73 8.2 50.0* 13 000 -20 ...+70 60 000 / 30 000 110 000 3218 JN 130 76.5 48 36...56 51 6.1 7.0 6 000 -20 ...+70 70 000 / 35 000 117 500 3218 JH 146 86.0 48 36...53 55 6.4 9.5 6 800 -20 ...+70 70 000 / 35 000 117 500 3218 JH3 237 139.5 48 20...58.0 69 7.8 29.0* 11 000 -20 ...+70 65 000 / 32 500 110 000 3218 JH4 280 164.8 48 20...58.0 73 8.2 50.0* 13 000 -20 ...+70 60 000 / 30 000 110 000 dB(A) Bel(A) Hours Hours DC fans - specials cfm ¿ ¡ ¬ √ ¿ ¡ ¬ √ ACmaxx / EC fans m3/h ¿ ¡ ¬ √ AC axial fans Type Nominal data Curve Life expectancy L10IPC (40 °C) see page 17 Service life L10 (Tmax) ebm-papst standard Service life L10 (40 °C) ebm-papst standard Temperature range Power consumption* Nominal speed Sintec sleeve bearings Ball bearings Sound power level °C Voltage range rpm-1 Nominal voltage Watts Air flow / Air flow Series 3200 J Sound pressure level 1) Fiberglass-reinforced plastic DC axial fans DC axial fans 3 DC centrifugal fans 280 m /h Subject to change AC centrifugal fans 3200 JH3 and JH4 also available as standard with PWM control input and speed signal. Speed control range from 2000 rpm-1 up to maximum nominal speed. Standstill at 0% PWM, maximum speed if control cable is interrupted. * Power consumption at free air flow. These values can be significantly higher in the operating point. ted Accessories Tin-p la Finger guards from p. 242 51 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Representatives Max. Max. 270 m /h DC axial fans 3 92 x 38 mm Housing: GRP1) (PBT) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Clockwise, looking towards rotor Connection: Via single wires AWG 22, TR 64 Weight: 240 g – Material: – – – – – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - External temperature sensor - Internal temperature sensor - PWM control input - Analog control input - Moisture protection - Salt spray protection - Degree of protection: IP 54 / IP 68 m3/h cfm VDC VDC 3252 J/2 H3P 270 158 12 7...13.2 64 7.6 35.0 7 450 -20...+70 85 000 / 42 500 142 500 3254 J/2 H3P 270 158 24 14...26.4 64 7.6 35.0 7 450 -20...+70 85 000 / 42 500 142 500 3258 J/2 HP** 145 85 48 36...56.0 46 5.8 7.0 4 100 -20...+70 100 000 / 50 000 170 000 3258 J/2 HHP 235 138 48 36...56.0 59 7.0 24.3 6 650 -20...+70 90 000 / 45 000 152 500 3258 J/2 H3P 270 158 48 36...56.0 64 7.6 33.6 7 450 -20...+70 85 000 / 42 500 142 500 dB(A) Bel(A) Subject to change ** On request * Power consumption at free air flow. These values can be significantly higher in the operating point. 3 2 Tin-p la 1 cfm 52 Finger guards from p. 242 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parametersmust be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions ted Hours Hours Curve Temperature range Life expectancy L10IPC (40 °C) see page 17 Nominal speed Service life L10 (Tmax) ebm-papst standard Power consumption* Type Nominal data 2016-01 Service life L10 (40 °C) ebm-papst standard Sintec sleeve bearings Ball bearings Sound power level °C Voltage range rpm-1 Nominal voltage Watts Air flow / Air flow Series 3250 J Sound pressure level 1) Fiberglass-reinforced plastic ¬ ¬ ¿ ¡ ¬ Information 170 m /h DC axial fans 3 119 x 25 mm – – – DC axial fans – – – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - Alarm with speed limit - External temperature sensor - Internal temperature sensor - PWM control input - Analog control input - Moisture protection DC centrifugal fans Housing: GRP1) (PBT) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Counterclockwise, looking towards rotor Connection: Via single wires AWG 24, TR 64 Highlights: Ball bearings and sleeve bearings available Weight: 175 g – Material: Hours Hours 94 55 12 7...14 26 3.9 1.3 1 600 -20...+75 80 000 / 32 500 135 000 4412 FGML 114 67 12 7...12.6 32 4.3 2.0 1 950 -20...+75 75 000 / 30 000 127 500 4412 FML 114 67 12 7...12.6 32 4.3 2.0 1 950 -20...+75 75 000 / 30 000 127 500 4412 FGM 140 82 12 7...12.6 38 4.8 3.2 2 400 -20...+75 70 000 / 27 500 117 500 4412 FM 140 82 12 7...12.6 38 4.8 3.2 2 400 -20...+75 70 000 / 27 500 117 500 4412 FG 170 100 12 8...12.6 43 5.3 5.3 2 900 -20...+60 60 000 / 37 500 102 500 4412 F 170 100 12 8...12.6 43 5.3 5.3 2 900 -20...+60 60 000 / 37 500 102 500 4414 FL 94 55 24 18...28 26 3.9 1.2 1 600 -20...+75 80 000 / 32 500 135 000 4414 FM 140 82 24 12...28 38 4.8 3.1 2 400 -20...+75 70 000 / 27 500 117 500 4414 FG 170 100 24 12...28 43 5.3 5.0 2 900 -20...+60 60 000 / 37 500 102 500 4414 F 170 100 24 12...28 43 5.3 5.0 2 900 -20...+60 60 000 / 37 500 102 500 4418 FG 170 100 48 28...53 43 5.3 5.4 2 900 -20...+60 60 000 / 37 500 102 500 4418 F 170 100 48 28...53 43 5.3 5.4 2 900 -20...+60 60 000 / 37 500 102 500 DC fans - specials °C ¿ ¡ ¡ ¬ ¬ √ √ ACmaxx / EC fans rpm-1 Curve Life expectancy L10IPC (40 °C) see page 17 Service life L10 (Tmax) ebm-papst standard Watts Service life L10 (40 °C) ebm-papst standard / Temperature range dB(A) Bel(A) Nominal speed VDC Power consumption VDC Sintec sleeve bearings Ball bearings cfm Sound power level Voltage range m3/h ¿ ¬ √ √ √ √ AC axial fans 4412 FGL Nominal voltage Type Air flow Nominal data Air flow Series 4400 F Sound pressure level 1) Fiberglass-reinforced plastic Subject to change Finger guards from p. 242 Accessories Tin-p la ted 53 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions AC centrifugal fans Available as an option: Fan housing with molded-in spacers Representatives Max. Max. 170 m /h DC axial fans 3 Ø 127 mm – Possible special versions: Housing: GRP1) (PBT) (See chapter DC fans - specials) Impeller: GRP1) (PA) - Speed signal Direction of air flow: Exhaust over struts - Go / NoGo alarm Direction of rotation: Counterclockwise, - External temperature sensor looking towards rotor - Internal temperature sensor Connection: Via single wires AWG 24, TR 64 - PWM control input Highlights: Ball bearings and sleeve - Analog control input bearings available - Moisture protection Optional: - Reversible direction of rotation - Reversible direction of - Symmetrical impeller rotation - Symmetrical impeller Weight: 170 g – Material: – – – – – 80 000 / 32 500 135 000 -20...+75 75 000 / 30 000 127 500 3.2 2 400 -20...+75 75 000 / 27 500 117 500 5.3 2 900 -20...+60 60 000 / 37 500 102 500 VDC VDC NEW 4412 FGML* 91 54 12 7...15 26 3.9 1.2 114 67 12 7...12.6 32 4.3 2.0 NEW 4412 FG* 140 82 12 7...12.6 38 4.8 170 100 12 8...12.6 43 5.3 NEW 4412 FGM* Curve -20...+75 1 950 cfm NEW 4412 FGL-573 Life expectancy L10IPC (40 °C) see page 17 1 600 m3/h dB(A) Bel(A) Service life L10 (Tmax) ebm-papst standard Hours Type Nominal data Service life L10 (40 °C) ebm-papst standard Temperature range Power consumption °C Voltage range rpm-1 Nominal voltage Nominal speed Sintec sleeve bearings Ball bearings Watts Air flow Sound power level / Air flow Series 4400 F Sound pressure level 1) Fiberglass-reinforced plastic Hours ¿ ¬ ¬ √ Subject to change Other voltage versions (24 VDC, 48 VDC), speed variations and ball bearing designs are available as additional variants. * On request n rpm-1 Ped W LwA dB(A) 1515 1516 1547 1567 1 1 1 1 44 38 40 39 1856 1848 1882 1929 2 2 2 2 50 44 44 46 Ped W LwA dB(A) 2225 2235 2304 2369 4 4 4 4 51 50 51 52 2670 2685 2783 2869 6 6 6 6 59 59 56 57 4 0,2 200 150 n rpm-1 ,5 27 Ø1 0,15 3 100 0,1 2 0,05 1 50 0 20 2016-01 20 54 40 40 60 60 80 Finger guards from p. 242 100 80 120 140 cfm Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parametersmust be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Tin-plated ±0 Information 225 m /h DC axial fans 3 119 x 25 mm – – DC axial fans – – – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - Alarm with speed limit - External temperature sensor - Internal temperature sensor - PWM control input - Analog control input - Moisture protection DC centrifugal fans Housing: GRP1) (PBT) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Counterclockwise, looking towards rotor Connection: Via single wires AWG 22, TR 64 Weight: 240 g – Material: 5 400 -20...+70 60 000 / 30 000 102 500 8.3 4 850 -20...+70 60 000 / 30 000 102 500 6.7 12 5 400 -20...+70 60 000 / 30 000 102 500 6.7 12 5 400 -20...+70 60 000 / 30 000 102 500 Air flow Nominal voltage Voltage range VDC VDC 4412 FNH 225 132 12 9...13.2 55 6.7 12 4414 FNN 200 118 24 14...28 52 6.5 4414 FNH 225 132 24 18...26.4 55 4418 FNH 225 132 48 36...53 55 dB(A) Bel(A) DC fans - specials Hours cfm ¡ ¿ ¡ ¡ ACmaxx / EC fans Hours m3/h Curve Life expectancy L10IPC (40 °C) see page 17 Service life L10 (Tmax) ebm-papst standard °C Type Nominal data Service life L10 (40 °C) ebm-papst standard rpm-1 Sound power level Temperature range Power consumption Watts Nominal speed Sintec sleeve bearings Ball bearings / Air flow Series 4400 FN Sound pressure level 1) Fiberglass-reinforced plastic AC centrifugal fans AC axial fans Subject to change ted Accessories Tin-p la Finger guards from p. 242 55 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Representatives Max. Max. 204 m /h DC axial fans 3 119 x 32 mm Housing: GRP1) (PBT) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Clockwise, looking towards rotor Connection: Via single wires AWG 22, TR 64 Highlights: Ball bearings and sleeve bearings available Weight: 220 g – Material: – – – – – – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - Alarm with speed limit - External temperature sensor - Internal temperature sensor - PWM control input - Analog control input - Moisture protection - Salt spray protection - Degree of protection: IP 54 / IP 68 dB(A) Bel(A) Hours 4312 GL 95 56 12 6...15 30 4.3 1.2 1 550 -20...+75 80 000 / 35 000 135 000 4312 L 95 56 12 6...15 30 4.3 1.2 1 550 -20...+75 80 000 / 35 000 135 000 4312 GM 140 82 12 6...15 39 5.3 3.1 2 300 -20...+75 70 000 / 30 000 117 500 4312 M 140 82 12 6...15 39 5.3 3.1 2 300 -20...+75 70 000 / 30 000 117 500 4312 G 170 100 12 6...15 45 5.8 5.0 2 800 -20...+70 62 500 / 30 000 105 000 4312 170 100 12 6...15 45 5.8 5.0 2 800 -20...+70 62 500 / 30 000 105 000 4312-179 204 120 12 6...13.2 51 6.4 9.4 3 400 -20...+65 47 500 / 27 500 80 000 4314 L 95 56 24 12...28 30 4.3 1.2 1 550 -20...+75 80 000 / 35 000 135 000 4314 M 140 82 24 12...28 39 5.3 2.8 2 300 -20...+75 70 000 / 30 000 117 500 4314 G 170 100 24 12...28 45 5.8 4.7 2 800 -20...+75 62 500 / 27 500 105 000 4314 170 100 24 12...28 45 5.8 5.0 2 800 -20...+75 62 500 / 27 500 105 000 4314-147 180 106 24 12...28 47 6.1 4.7 3 000 -20...+75 57 500 / 25 000 80 000 4314-180 204 120 24 12...26 51 6.4 8.5 3 400 -20...+70 45 000 / 22 500 75 000 4318 M 140 82 48 36...56 39 5.3 3.6 2 300 -20...+75 70 000 / 30 000 117 500 4318 170 100 48 36...53 45 5.8 5.1 2 800 -20...+75 62 500 / 27 500 105 000 Subject to change Rotor protrusion max. 0.4 mm. Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 2016-01 Hours 56 Finger guards from p. 242 Tin-p la ted Curve °C Life expectancy L10IPC (40 °C) see page 17 rpm-1 Service life L10 (Tmax) ebm-papst standard Watts Service life L10 (40 °C) ebm-papst standard / Temperature range VDC Nominal speed VDC Power consumption cfm Sintec sleeve bearings Ball bearings Voltage range m3/h Sound power level Nominal voltage Type Air flow Nominal data Air flow Series 4300 Sound pressure level 1) Fiberglass-reinforced plastic ¿ ¿ ¡ ¡ ¬ ¬ ƒ ¿ ¡ ¬ ¬ √ ƒ ¡ ¬ Information 170 m /h DC axial fans 3 119 x 32 mm – – – DC axial fans – – – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - Alarm with speed limit - External temperature sensor - Internal temperature sensor - PWM control input - Analog control input - Moisture protection DC centrifugal fans Housing: GRP1) (PBT) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Clockwise, looking towards rotor Connection: Via single wires AWG 22, TR 64 Highlights: Speed automatically adjusted to cooling requirement Weight: 220 g – Material: 85 50 170 100 85 50 170 100 12 8...15 12 8...13.2 24 18...32 rpm-1 °C Hours Hours -20...+65 70 000 / 40 000 117 500 -20...+65 65 000 / 35 000 110 000 -20...+65 65 000 / 35 000 110 000 25 3.9 1.1 1 100 39 5.3 3.3 2 300 29 4.2 1.7 1 400 45 5.8 5.0 2 800 29 4.2 1.6 1 400 45 5.8 4.8 2 800 Curve Life expectancy L10IPC (40 °C) see page 17 Service life L10 (Tmax) ebm-papst standard Power consumption Watts Service life L10 (40 °C) ebm-papst standard Sintec sleeve bearings Ball bearings / DC fans - specials 38 81 dB(A) Bel(A) ¿ ¡ ¬ √ ACmaxx / EC fans 65 138 Sound power level Voltage range VDC ¬ √ AC axial fans Subject to change AC centrifugal fans The temperature sensor for controlling the motor speed is not included in the scope of delivery. For the temperature sensor LZ 370, see accessories. Rotor protrusion max. 0.4 mm. Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Finger guards from p. 242 Accessories 50°C 4314 T VDC Tin-p la ted 57 2016-01 30°C 4312 T cfm Temperature range 25°C 50°C 4312 MT m3/h Nominal speed 25°C 50°C Nominal voltage Type Air flow Nominal data Air flow Series 4300 VARIOFAN Sound pressure level 1) Fiberglass-reinforced plastic Representatives Max. Max. 205 m /h DC axial fans 3 119 x 38 mm Housing: GRP1) (PBT) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Clockwise, looking towards rotor Connection: Via single wires AWG 24, TR 64 Weight: 270 g – Material: – – – – – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - Alarm with speed limit - External temperature sensor - Internal temperature sensor - PWM control input - Analog control input - Moisture protection - Degree of protection: IP 54 m3/h cfm VDC VDC 4412 L 150 88 12 7...14 37 5.0 2.2 2 700 -20...+80 67 500 / 22 500 115 000 4412 ML 168 99 12 7...15 40 5.1 3.0 3 000 -20...+80 67 500 / 22 500 115 000 4412 M 184 108 12 7...14 42 5.3 3.8 3 300 -20...+75 65 000 / 25 000 110 000 4412 N 205 121 12 7...14 46 5.6 5.3 3 650 -20...+70 62 500 / 30 000 105 000 4414 L3 100 59 24 12...28 26 4.0 1.0 1 800 -20...+80 75 500 / 22 500 127 500 4414 LL 124 73 24 12...28 33 4.5 1.6 2 250 -20...+80 70 000 / 22 500 117 500 4414 L 150 88 24 18...28 37 5.0 2.4 2 700 -20...+80 67 500 / 22 500 115 000 4414 ML 168 99 24 12...28 40 5.1 3.2 3 000 -20...+80 67 500 / 22 500 115 000 4414 M 184 108 24 18...28 42 5.3 4.1 3 300 -20...+75 65 000 / 25 000 110 000 4414 N 205 121 24 18...28 46 5.6 5.4 3 650 -20...+70 62 500 / 30 000 105 000 4418 L 150 88 48 36...60 37 5.0 2.5 2 700 -20...+75 67 500 / 27 500 115 000 4418 ML 168 99 48 36...60 40 5.1 3.2 3 000 -20...+75 67 500 / 27 500 115 000 4418 M 184 108 48 36...60 42 5.3 4.2 3 300 -20...+70 65 000 / 32 500 110 000 4418 N 205 121 48 36...60 46 5.6 5.4 3 650 -20...+70 62 500 / 30 000 105 000 dB(A) Bel(A) Subject to change Further variants can be found on page 59. Tin-p la Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 58 Finger guards from p. 242 ted Hours Hours Curve Life expectancy L10IPC (40 °C) see page 17 Service life L10 (Tmax) ebm-papst standard Type Nominal data 2016-01 Service life L10 (40 °C) ebm-papst standard Temperature range Power consumption Nominal speed Sintec sleeve bearings Ball bearings Sound power level °C Voltage range rpm-1 Nominal voltage Watts Air flow / Air flow Series 4400 Sound pressure level 1) Fiberglass-reinforced plastic ¬ √ ƒ ≈ ¿ ¡ ¬ √ ƒ ≈ ¬ √ ƒ ≈ Information 285 m /h DC axial fans 3 119 x 38 mm – – DC axial fans – – – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - Alarm with speed limit - External temperature sensor - Internal temperature sensor - PWM control input - Analog control input - Moisture protection - Degree of protection: IP 54 DC centrifugal fans Housing: GRP1) (PBT) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Clockwise, looking towards rotor Connection: Via single wires AWG 24, TR 64 Weight: 270 g – Material: -20...+70 57 500 / 27 500 97 500 -20...+70 50 000 / 25 000 85 000 4 300 -20...+70 57 500 / 27 500 97 500 5 000 -20...+70 50 000 / 25 000 85 000 12.0 5 000 -20...+70 50 000 / 25 000 85 000 6.0 8.6 4 300 -20...+70 57 500 / 27 500 97 500 6.4 13.0 5 000 -20...+70 50 000 / 25 000 85 000 Air flow Nominal voltage Voltage range VDC VDC 4412 H 240 141 12 7...14 50 6.0 8.6 4412/2 HHP 285 168 12 7...14.5 55 6.4 13.0 4414 H 240 141 24 18...28 50 6.0 8.6 4414 HH 285 165 24 16...28 55 6.4 14.0 4414/2 HHP 285 168 24 18...28 55 6.4 4418 H 240 141 48 36...60 50 4418/2 HHP 285 168 48 36...60 55 dB(A) Bel(A) Hours DC fans - specials 4 300 5 000 cfm ¿ ¡ ¿ ¡ ¡ ACmaxx / EC fans Hours m3/h Curve Life expectancy L10IPC (40 °C) see page 17 Service life L10 (Tmax) ebm-papst standard °C Type Nominal data Service life L10 (40 °C) ebm-papst standard rpm-1 Sound power level Temperature range Power consumption Watts Nominal speed Sintec sleeve bearings Ball bearings / Air flow Series 4400 Sound pressure level 1) Fiberglass-reinforced plastic ¿ ¡ AC centrifugal fans AC axial fans Subject to change ted Accessories Tin-p la Finger guards from p. 242 59 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Representatives Max. Max. 237 m /h DC axial fans 3 119 x 38 mm – Possible special versions: Housing: Die-cast aluminum (See chapter DC fans - specials) Impeller: GRP1) (PA) - Speed signal Direction of air flow: Intake over struts - Go / NoGo alarm Direction of rotation: Clockwise, - Alarm with speed limit looking towards rotor - External temperature sensor Connection: On flat connectors, 2.8 x 0.5 mm - Internal temperature sensor Also available with wires as - PWM control input an option - Analog control input Highlights: Housing with grounding lug for - Moisture protection screw M4 x 8 (Torx) - Salt spray protection Weight: 390 g - Degree of protection: IP 54 / IP 68 – Material: – – – – – dB(A) Bel(A) Hours Hours 160 94 12 6...15 44 5.3 3.7 2 800 -20...+75 85 000 / 37 500 142 500 4182 NX 180 106 12 6...15 49 5.7 4.9 3 200 -30...+75 85 000 / 37 500 142 500 4182 NXH 237 140 12 7...14 57 6.5 11.0 4 400 -30...+55 70 000 / 50 000 117 500 4184 NGX 160 94 24 12...31.5 44 5.3 3.3 2 800 -20...+75 85 000 / 37 500 142 500 4184 NXM 160 94 24 12...31.5 44 5.3 3.2 2 800 -30...+75 85 000 / 37 500 142 500 4184 NX 180 106 24 12...31.5 49 5.7 4.9 3 200 -30...+70 85 000 / 42 500 142 500 4184 NXH 237 140 24 12...28 57 6.5 11.0 4 400 -30...+70 70 000 / 35 000 117 500 4188 NGX 160 94 48 36...60 44 5.3 3.6 2 800 -20...+75 85 000 / 37 500 142 500 4188 NXM 160 94 48 36...60 44 5.3 3.5 2 800 -30...+75 85 000 / 37 500 142 500 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 60 Finger guards from p. 242 Cables P. 255 Curve Life expectancy L10IPC (40 °C) see page 17 °C 4182 NGX Subject to change 2016-01 rpm-1 Service life L10 (Tmax) ebm-papst standard Watts Service life L10 (40 °C) ebm-papst standard / Temperature range VDC Nominal speed VDC Power consumption cfm Sintec sleeve bearings Ball bearings Voltage range m3/h Sound power level Nominal voltage Type Air flow Nominal data Air flow Series 4100 N Sound pressure level 1) Fiberglass-reinforced plastic ¿ ¡ ¬ ¿ ¿ ¡ ¬ ¿ ¿ 440 m /h Information Max. DC axial fans 3 119 x 38 mm – Possible special versions: Housing: Die-cast aluminum (See chapter DC fans - specials) Impeller: GRP1) (PA) - Speed signal Direction of air flow: Intake over struts - Go / NoGo alarm Direction of rotation: Clockwise, - Alarm with speed limit looking towards rotor - External temperature sensor Connection: Via single wires - Internal temperature sensor AWG 22 UL 1007, - PWM control input TR 64 - Analog control input Highlights: Housing with grounding lug for - Moisture protection screw M4 x 8 (Torx) - Salt spray protection Weight: 390 g - Degree of protection:IP 54 / IP 68 – – – 5 000 -20...+65 70 000 / 55 000 117 500 6 000 -20...+65 65 000 / 37 500 110 000 32.0 6 800 -20...+65 62 500 / 35 000 105 000 6.8 12.4 5 000 -20...+65 70 000 / 52 500 117 500 7.2 19.5 6 000 -20...+65 65 000 / 37 500 110 000 Air flow Nominal voltage Voltage range VDC 4112 NHH 260 153 12 9...15 60 6.8 13.3 4112 NH3 310 182 12 9...15 65 7.2 21.6 4112 NH4 355 209 12 9...14 67 7.4 4114 NHH 260 153 24 16...30 60 4114 NH3 310 182 24 16...30 65 4114 NH4 355 209 24 16...30 67 7.4 30.0 6 800 -20...+65 62 500 / 35 000 105 000 4114 NH5 390 230 24 16...30 70 7.6 45.0* 7 500 -20...+65 62 500 / 35 000 105 000 4114 NH6 440 259 24 16...30 73 8.1 65.0* 8 400 -20...+65 60 000 / 32 500 102 500 4118 NHH 260 153 48 36...60 60 6.8 12.0 5 000 -20...+65 70 000 / 52 500 117 500 4118 NH3 310 182 48 36...60 65 7.2 20.0 6 000 -20...+65 65 000 / 37 500 110 000 4118 NH4 355 209 48 36...60 67 7.4 28.0 6 800 -20...+65 62 500 / 35 000 105 000 4118 NH5 390 230 48 36...60 70 7.6 45.0* 7 500 -20...+65 62 500 / 35 000 105 000 4118 NH6 440 259 48 36...60 73 8.1 62.0* 8 400 -20...+65 60 000 / 32 500 102 500 ¿ ¡ ¬ ¿ ¡ ¬ √ ƒ ¿ ¡ ¬ √ ƒ * Power consumption at free air flow. These values can be significantly higher in the operating point. 4114 NH5 55 4114 NH6 95 4118 NH5 55 4118 NH6 95 Tin-p la ted Accessories optimum operating range (W) Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Finger guards from p. 242 61 Representatives Fan type AC centrifugal fans * Power consumption – in operation 2016-01 Subject to change dB(A) Bel(A) DC fans - specials Hours VDC ACmaxx / EC fans Hours cfm Type AC axial fans °C m3/h Nominal data Curve Life expectancy L10IPC (40 °C) see page 17 Service life L10 (Tmax) ebm-papst standard Service life L10 (40 °C) ebm-papst standard rpm-1 Sound power level Temperature range Power consumption* Watts Nominal speed Sintec sleeve bearings Ball bearings / Air flow Series 4100 N High Performance Sound pressure level 1) Fiberglass-reinforced plastic DC centrifugal fans – – DC axial fans – Material: Max. 570 m /h DC axial fans 3 119 x 38 mm – Possible special versions: Housing: Die-cast aluminum (See chapter DC fans - specials) Impeller: GRP1) (PA) - Speed signal Direction of air flow: Intake over struts - Go / NoGo alarm Direction of rotation: Clockwise, looking - Alarm with speed limit towards rotor - External temperature sensor Connection: Via single wires AWG 18, 20 or - Internal temperature sensor AWG 22, TR 64, speed signal - PWM control input (standard) and control input AWG 22 - Analog control input Highlights: Highly efficient and smoothly - Moisture protection operating 3-phase fan drive - Salt spray protection Housing with grounding lug for screw M4 x 8 (Torx) Weight: 425 g – Material: – – – – – m3/h cfm VDC VDC 4114 N/2 H7P 500 294 24 16...30 76 8.5 90 9 500 -20...+75 57 500 / 25 000 97 500 4114 N/2 H8P 570 336 24 16...30 78 8.9 120 11 000 -20...+75 55 000 / 22 500 92 500 4118 N/2 H7P 500 294 48 36...60* 76 8.5 90 9 500 -20...+75 57 500 / 25 000 97 500 4118 N/2 H8P 570 336 48 36...60* 78 8.9 120 11 000 -20...+75 55 000 / 22 500 92 500 Subject to change * 36...72 VDC on request. dB(A) Bel(A) Speed control range from 500 rpm-1 up to maximum nominal speed. Standstill at 0% PWM, maximum speed if control cable is interrupted. To attain the specified service life, an external capacitor must be wired between the plus and minus strands. Please note the wiring suggestion on page 16. ** Power consumption at free air flow, these values can be significantly higher in the operating point. ** Power consumption - in operation Fan type optimum operating range (W) 4114 NH7P 100 4114 NH8P 160 4118 NH7P 100 4118 NH8P 160 Tin-p la Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 62 Finger guards from p. 242 ted Hours Hours Curve Life expectancy L10IPC (40 °C) see page 17 Service life L10 (Tmax) ebm-papst standard Type Nominal data 2016-01 Service life L10 (40 °C) ebm-papst standard Temperature range Power consumption** Nominal speed Sintec sleeve bearings Ball bearings Sound power level °C Voltage range rpm-1 Nominal voltage Watts Air flow / Air flow Series 4100 N High Performance Sound pressure level 1) Fiberglass-reinforced plastic ¿ ¡ ¿ ¡ 280 m /h Information Max. DC diagonal fan 3 119 x 38 mm – Possible special versions: Housing: GRP1) (PBT) (See chapter DC fans - specials) Available in die-cast aluminum - Speed signal Impeller: GRP1) (PA) - Go / NoGo alarm Direction of air flow: Exhaust over struts - Alarm with speed limit Direction of rotation: Counterclockwise, - External temperature sensor looking towards rotor - Internal temperature sensor Connection: Via single wires AWG 22, - PWM control input TR 64 - Analog control input Highlights: Housing with grounding lug for - Moisture protection screw M4 x 8 (Torx) - Salt spray protection Weight: 375 g (with metal housing: 455 g) - Degree of protection: IP 54 / IP 68 – – – -20...+65 70 000 / 40 000 117 500 20.5 6 000 -20...+65 70 000 / 40 000 117 500 20.0 6 000 -20...+65 70 000 / 40 000 117 500 VDC VDC DV 4112 N 280 165 12 9...15 61 6.9 21.0 DV 4114 N 280 165 24 16...30 61 6.9 DV 4118 N 280 165 48 36...60 61 6.9 DC fans - specials 6 000 cfm Curve Life expectancy L10IPC (40 °C) see page 17 Hours m3/h dB(A) Bel(A) Service life L10 (Tmax) ebm-papst standard Hours Type ¿ ¿ ¿ ACmaxx / EC fans Subject to change Finger guards from p. 242 Tin-p la ted 63 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Accessories AC centrifugal fans AC axial fans * Power consumption at free air flow. These values can be significantly higher in the operating point. Representatives Nominal data Service life L10 (40 °C) ebm-papst standard Temperature range Power consumption* °C Voltage range rpm-1 Nominal voltage Nominal speed Sintec sleeve bearings Ball bearings Watts Air flow Sound power level / Air flow Series DV 4100 Sound pressure level 1) Fiberglass-reinforced plastic DC centrifugal fans – – DC axial fans – Material: Max. 340 m /h DC axial fans 3 127 x 38 mm Housing: GRP1) (PBT) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Counterclockwise, looking towards rotor Connection: Via single wires AWG 22, TR 64 Weight: 310 g – Material: – – – – – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - Alarm with speed limit - External temperature sensor - Internal temperature sensor - PWM control input - Analog control input - Moisture protection - Salt spray protection - Degree of protection: IP 54 / IP 68 Type m3/h cfm VDC VDC 5212 NM 187 110 12 7...14.5 43 5.3 4.1 2 750 5212 NN 216 127 12 7...14 46 5.6 6.2 3 150 5212 NH 252 148 12 7...14 51 6.0 9.8 3 650 -20...+70 45 000 / 22 500 75 000 5212 NHH* 340 200 12 9...15 58 6.6 19.0 4 900 -20...+65 45 000 / 25 000 75 000 5214 NM 187 110 24 12...28 43 5.3 4.6 2 750 -20...+75 62 500 / 27 500 105 000 5214 NN 216 127 24 12...28 46 5.6 6.0 3 150 -20...+75 57 500 / 25 000 97 500 5214 NH 252 148 24 12...28 51 6.0 9.8 3 650 -20...+70 45 000 / 22 500 75 000 5214 NHH* 340 200 24 16...30 58 6.6 17.5 4 900 -20...+65 45 000 / 25 000 75 000 5218 NM 187 110 48 36...56 43 5.3 4.5 2 750 -20...+75 62 500 / 27 500 105 000 5218 NN 216 127 48 36...56 46 5.6 6.2 3 150 -20...+70 57 500 / 32 500 97 500 5218 NH 252 148 48 36...56 51 6.0 9.6 3 650 -20...+55 45 000 / 32 500 75 000 5218 NHH* 340 200 48 36...60 58 6.6 18.0 4 900 -20...+65 45 000 / 25 000 75 000 Nominal data Subject to change dB(A) Bel(A) Hours Hours -20...+75 62 500 / 27 500 105 000 -20...+70 57 500 / 25 000 97 500 Curve Life expectancy L10IPC (40 °C) see page 17 Service life L10 (Tmax) ebm-papst standard Service life L10 (40 °C) ebm-papst standard Temperature range Power consumption** Nominal speed Sintec sleeve bearings Ball bearings Sound power level °C Voltage range rpm-1 Nominal voltage Watts Air flow / Air flow Series 5200 N Sound pressure level 1) Fiberglass-reinforced plastic ¿ ¡ ¬ √ ¿ ¡ ¬ √ ¿ ¡ ¬ √ ** Power consumption at free air flow, these values can be significantly higher in the operating point. *NHH models: fan housing with molded-in spacers. Tin-p la 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axi. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parametersmust be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 64 Finger guards from p. 242 ted 320 m /h Information Max. DC diagonal fan 3 127 x 38 mm – Possible special versions: Housing: GRP1) (PBT) (See chapter DC fans - specials) Available in Die-cast aluminum - Speed signal Metal flange - Go / NoGo alarm Impeller: GRP1) (PA) - Alarm with speed limit Direction of air flow: Exhaust over struts - External temperature sensor Direction of rotation: Counterclockwise, - Internal temperature sensor looking towards rotor - PWM control input Connection: Via single wires AWG 22, - Analog control input TR 64 - Moisture protection Highlights: Housing with grounding lug for - Salt spray protection screw M4 x 8 (Torx) - Degree of protection: IP 54 Weight: 415 g (with metal housing: 490 g) – – – DC centrifugal fans – – DC axial fans – Material: -20...+65 70 000 / 40 000 117 500 20.4 5 000 -20...+65 70 000 / 40 000 117 500 18.5 5 000 -20...+65 70 000 / 40 000 117500 ¿ 38.5 6 000 -20...+65 62 500 / 35 000 105 000 ¡ VDC DV 5212 N 270 159 12 9...15 56 6.4 21.0 DV 5214 N 270 159 24 16...30 56 6.4 DV 5218 N 270 159 48 36...60 56 6.4 Standard model comes with speed signal and PWM control input. Other versions by request. 320 188 24 16...30 62 7.2 ¿ ¿ Subject to change AC centrifugal fans AC axial fans Speed control range from 1000 rpm-1 up to maximum nominal speed. Standstill at 0% PWM, maximum speed if control cable is interrupted. * Power consumption at free air flow. These values can be significantly higher in the operating point. ted Accessories Tin-p la Finger guards from p. 242 65 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Representatives DV 5214/2 HP DC fans - specials VDC Curve 5 000 cfm ACmaxx / EC fans Life expectancy L10IPC (40 °C) see page 17 Hours m3/h dB(A) Bel(A) Service life L10 (Tmax) ebm-papst standard Hours Type Nominal data Service life L10 (40 °C) ebm-papst standard Temperature range Power consumption* °C Voltage range rpm-1 Nominal voltage Nominal speed Sintec sleeve bearings Ball bearings Watts Air flow Sound power level / Air flow Series DV 5200 Sound pressure level 1) Fiberglass-reinforced plastic 260 m /h DC axial fans 3 135 x 38 mm -25...+72 80 000 / 37 500 135 000 9.5 2 900 -25...+72 80 000 / 37 500 135 000 9.5 2 900 -25...+72 80 000 / 37 500 135 000 cfm VDC VDC 5112 N 260 153 12 6...15 48 6.1 9.5 5114 N 260 153 24 12...30 48 6.1 5118 N 260 153 48 24...60 48 6.1 Subject to change * Power consumption at free air flow. These values can be significantly higher in the operating point. 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 66 Finger guards from p. 242 Tin-p la ted Curve 2 900 m3/h dB(A) Bel(A) Life expectancy L10IPC (40 °C) see page 17 Hours Voltage range Hours Nominal voltage °C Air flow rpm-1 Type Nominal data Service life L10 (40 °C) ebm-papst standard Watts Temperature range / Air flow Series 5100 N Sound pressure level – – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - Alarm with speed limit - External temperature sensor - Internal temperature sensor - PWM control input - Analog control input - Moisture protection - Salt spray protection - Degree of protection: IP 54 Nominal speed – Power consumption* – Sintec sleeve bearings Ball bearings – – Housing: Die-cast aluminum Impeller: painted sheet steel Direction of air flow: Exhaust over struts Direction of rotation: Counterclockwise, looking towards rotor Connection: Via single wires AWG 22, TR 64 Highlights: Housing with grounding lug for screw M4 x 8 (Torx) 48 V design incl. screws. Weight: 650 g Sound power level – Material: Service life L10 (Tmax) ebm-papst standard Max. ¿ ¿ ¿ 340 m /h Information Max. DC axial fans 3 140 x 51 mm – Possible special versions: Housing: Die-cast aluminum (See chapter DC fans - specials) Impeller: GRP1) (PA) - Speed signal Direction of air flow: Intake over struts - Go / NoGo alarm Direction of rotation: Counterclockwise, - Alarm with speed limit looking towards rotor - External temperature sensor Connection: Via single wires AWG 22, - Internal temperature sensor TR 64 - PWM control input Highlights: Housing with grounding lug for - Analog control input screw M4 x 8 (Torx) - Moisture protection Weight: 900 g - Salt spray protection - Degree of protection: IP 54 – – – DC centrifugal fans – – DC axial fans – Material: 340 200 24 16...28 64 7.2 28.4 5318/2 HP 340 200 48 36...72 64 7.2 27 rpm-1 °C Hours Hours 5 000 -20...+65 77 500 / 40 000 130 000 5 000 -20...+65 77 500 / 40 000 130 000 DC fans - specials 5314/2 HP dB(A) Bel(A) Curve VDC Life expectancy L10IPC (40 °C) see page 17 VDC Service life L10 (Tmax) ebm-papst standard cfm Service life L10 (40 °C) ebm-papst standard m3/h Temperature range Power consumption* Type Nominal data Nominal speed Sintec sleeve bearings Ball bearings Voltage range Sound power level Nominal voltage Watts Air flow / Air flow Series 5300 Sound pressure level 1) Fiberglass-reinforced plastic ¿ ¿ Subject to change AC centrifugal fans AC axial fans ACmaxx / EC fans Speed control range from 700 rpm-1 up to maximum nominal speed. Standstill at 0% PWM, maximum speed if control cable is interrupted. * Power consumption at free air flow. These values can be significantly higher in the operating point. Accessories ted Finger guards from p. 242 67 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Representatives Tin-p la Max. 670 m /h DC axial fans 3 140 x 51 mm – Possible special versions: Housing: Die-cast aluminum (See chapter DC fans - specials) Impeller: GRP1) (PA) - Speed signal Direction of air flow: Intake over struts - Go / NoGo alarm Direction of rotation: Counterclockwise, - Alarm with speed limit looking towards rotor - External temperature sensor Connection: Via single wires AWG 20 and - Internal temperature sensor AWG 22, TR 64 - PWM control input Highlights: 3-phase fan drive with - Analog control input very smooth operation - Multi-option control input Housing with grounding lug for - Moisture protection screw M4 x 8 (Torx) - Salt spray protection Weight: 900 g - Degree of protection: IP 54 – Material: – – – – – 6 000 -20...+70 70 000 / 35 000 117 500 42 6 000 -20...+70 70 000 / 35 000 117 500 8.1 67 7 000 -20...+70 62 500 / 30 000 105 000 70 7.7 42 6 000 -20...+70 70 000 / 35 000 117 500 75 8.1 66 7 000 -20...+70 62 500 / 30 000 105 000 79 8.8 149 9 200 -20...+65 57 500 / 32 500 97 500 Air flow Nominal voltage Voltage range VDC 5312/2 TDHP 410 241 12 8...16 70 7.7 43 5314/2 TDHP 410 241 24 16...36 70 7.7 5314/2 TDHHP 490 288 24 16...36 75 5318/2 TDHP 410 241 48 36...72 5318/2 TDHHP 490 288 48 36...72 5318/2 TDH4P 670 394 48 36...72 dB(A) Bel(A) Subject to change Speed control range from 1000 rpm-1 up to maximum nominal speed. Standstill at 0% PWM, maximum speed if control cable is interrupted. * Power consumption at free air flow. These values can be significantly higher in the operating point. Tin-p la 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Finger guards from p. 242 ted Curve Hours VDC 68 Life expectancy L10IPC (40 °C) see page 17 Hours cfm Type Service life L10 (Tmax) ebm-papst standard °C m3/h Nominal data Service life L10 (40 °C) ebm-papst standard rpm-1 Sound power level Temperature range Power consumption* Watts Nominal speed Sintec sleeve bearings Ball bearings / Air flow Series 5300 TD Sound pressure level 1) Fiberglass-reinforced plastic ¿ ¿ ¡ ¿ ¡ ¬ 360 m /h Information Max. DC axial fans 3 Ø 150 x 38 mm Housing: Die-cast aluminum – Possible special versions: (See chapter DC fans - specials) Impeller: painted sheet steel - Speed signal Direction of air flow: Exhaust over struts - Go / NoGo alarm Direction of rotation: Counterclockwise, - Alarm with speed limit looking towards rotor - External temperature sensor Connection: Via single wires AWG 22, - Internal temperature sensor TR 64 - PWM control input Highlights: Housing with grounding lug for - Analog control input screw M4 x 8 (Torx) - Moisture protection Weight: 620 g - Salt spray protection - Degree of protection:IP 54 / IP 68 2 850 -25...+72 80 000 / 37 500 135 000 12.0 2 850 -25...+72 80 000 / 37 500 135 000 6.7 19.0 3 350 -25...+72 75 000 / 35 000 127 500 6.2 12.0 2 850 -25...+72 80 000 / 37 500 135 000 Air flow Nominal voltage Voltage range VDC 7112 N 308 181 12 6...15 53 6.2 12.0 7114 N 308 181 24 12...30 53 6.2 7114 NH 360 212 24 12...26.5 58 7118 N 308 181 48 24...60 53 dB(A) Bel(A) DC axial fans DC centrifugal fans Hours VDC DC fans - specials Hours cfm ¿ ¿ ¡ ¿ ACmaxx / EC fans °C m3/h Curve Life expectancy L10IPC (40 °C) see page 17 Service life L10 (Tmax) ebm-papst standard rpm-1 Type Subject to change AC centrifugal fans AC axial fans * Power consumption at free air flow. These values can be significantly higher in the operating point. Finger guards from p. 242 Tin-p la ted 69 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Accessories Wire fastened with cable tie. Strand fastened using cable tie; cable tie protrudes 1 mm. Representatives Nominal data Service life L10 (40 °C) ebm-papst standard Watts Temperature range / Air flow Series 7100 N Sound pressure level – Nominal speed – Power consumption* – Sound power level – – Sintec sleeve bearings Ball bearings – Material: Max. 360 m /h DC axial fans 3 Ø 150 x 55 mm – Material: – – – – – Housing: Die-cast aluminum Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Counterclockwise, looking towards rotor Connection: Via single wires AWG 22, TR 64 Highlights: Housing with grounding lug for screw M4 x 8 (Torx) Weight: 725 g – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - Alarm with speed limit - External temperature sensor - Internal temperature sensor - PWM control input - Analog control input - Moisture protection - Salt spray protection - Degree of protection: IP 54 / IP 68 -25...+72 80 000 / 37 500 135 000 12.0 3 050 -25...+72 80 000 / 37 500 135 000 12.0 3 050 -25...+72 80 000 / 37 500 135 000 VDC VDC 7212 N 360 212 12 6...15 53 6.2 12.0 7214 N 360 212 24 12...30 53 6.2 7218 N 360 212 48 24...60 53 6.2 Subject to change * Power consumption at free air flow. These values can be significantly higher in the operating point. 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Finger guards from p. 242 Tin-p la ted Curve 3 050 cfm 70 Life expectancy L10IPC (40 °C) see page 17 Hours m3/h dB(A) Bel(A) Service life L10 (Tmax) ebm-papst standard Hours Type Nominal data Service life L10 (40 °C) ebm-papst standard Temperature range Power consumption* °C Voltage range rpm-1 Nominal voltage Nominal speed Sintec sleeve bearings Ball bearings Watts Air flow Sound power level / Air flow Series 7200 N Sound pressure level 1) Fiberglass-reinforced plastic ¿ ¿ ¿ 480 m /h Information Max. DC axial fans 3 172 x 150 x 51 mm – Possible special versions: Housing: Die-cast aluminum (See chapter DC fans - specials) Impeller: GRP1) (PA) - Speed signal Direction of air flow: Exhaust over struts - Go / NoGo alarm Direction of rotation: Counterclockwise, - Alarm with speed limit looking towards rotor - External temperature sensor Connection: on flat plugs 3 x 0.5 mm - Internal temperature sensor Highlights: Housing with grounding lug for - PWM control input screw M4 x 8 (Torx) - Analog control input Weight: 760 g - Moisture protection - Salt spray protection - Degree of protection: IP 54 – – – DC centrifugal fans – – DC axial fans – Material: -20...+72 80 000 / 37 500 135 000 12 2 850 -20...+72 80 000 / 37 500 135 000 6.4 17 3 400 -20...+72 75 000 / 35 000 127 500 7.1 26 4 000 -20...+55** 70 000 / 50 000 117 500 57 6.4 17 3 400 -20...+72 75 000 / 35 000 127 500 63 7.1 26 4 000 -20...+55** 70 000 / 50 000 117 500 Air flow Nominal voltage Voltage range VDC 6412 M 350 206 12 8...15 52 6.0 12 6424 M 350 206 24 12...32 52 6.0 6424 410 241 24 12...28 57 6424 H 480 283 24 12...28 63 6448 410 241 48 28...60 6448 H* 480 283 48 28...60 dB(A) Bel(A) DC fans - specials 2 850 VDC ¿ ¿ ¡ ¬ ACmaxx / EC fans Hours cfm Curve Life expectancy L10IPC (40 °C) see page 17 Hours m3/h ¡ ¬ Finger guards from p. 242 Cables P. 255 7.5 d eep 71 Representatives Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Accessories AC centrifugal fans AC axial fans * Strand 310 mm. ** 72 °C versions on request *** Power consumption at free air flow, these values can be significantly higher in the operating point. 2016-01 Subject to change Service life L10 (Tmax) ebm-papst standard °C Type Nominal data Service life L10 (40 °C) ebm-papst standard rpm-1 Sound power level Temperature range Power consumption*** Watts Nominal speed Sintec sleeve bearings Ball bearings / Air flow Series 6400 Sound pressure level 1) Fiberglass-reinforced plastic Max. 900 m /h DC axial fans 3 172 x 150 x 51 mm – Possible special versions: Housing: Die-cast aluminum (See chapter DC fans - specials) Impeller: GRP1) (PA) - Speed signal Direction of air flow: Exhaust over struts - Go / NoGo alarm Direction of rotation: Counterclockwise, - Alarm with speed limit looking towards rotor - External temperature sensor Connection: Via single wires AWG 18, 20 or - Internal temperature sensor AWG 22, TR 64, speed signal - PWM control input and control input AWG 22 - Analog control input Highlights: Highly efficient and smoothly - Moisture protection operating 3-phase fan drive - Salt spray protection Housing with grounding lug - Degree of protection: IP 54 for screw M4 x 8 (Torx) - Reversible direction of rotation Weight: 760 g – Material: – – – – – Min 6448 TD... Max Min 6448 TDHH... Max Subject to change 90 53 600 353 90 53 600 353 90 53 900 530 24 16...28 48 40...55* 48 36...72 dB(A) Bel(A) rpm-1 °C Hours Hours -20...+60 70 000 / 45 000 117 500 -20...+60 70 000 / 45 000 117 500 -20...+60 70 000 / 45 000 117 500 18 — 2 800 65 7.4 50 5 100 18 — 2 800 65 7.4 50 5 100 18 — 2 800 78 8.6 163 7500 Curve Life expectancy L10IPC (40 °C) see page 17 Watts Service life L10 (Tmax) ebm-papst standard / Service life L10 (40 °C) ebm-papst standard Power consumption** VDC Sintec sleeve bearings Ball bearings VDC Sound power level Voltage range cfm Temperature range 6424 TD... m3/h Nominal speed Min Max Nominal voltage Type Air flow Nominal data Air flow Series 6400 TD Sound pressure level 1) Fiberglass-reinforced plastic ¿ ¡ ¿ ¡ ¿ ¬ * Variants with an extended voltage range available on request. Models 6424 TD..., 6448 TD... and 6448 TDHH... are available in customer-specific, custom-developed variants only. The figures indicated are technically feasible benchmark values. The fans can be specially adapted to your application with signal outputs and control inputs. For details of the technical possibilities, refer to the chapters on the sensor signal, alarm signal and control inputs beginning on page 165. ** Power consumption at free air flow, these values can be significantly higher in the operating point. Tin-plate 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 72 Finger guards from p. 242 (7.5 deep) d Information Max. DC diagonal fan 530 m /h 3 172 x 160 x 51 mm – Possible special versions: Housing: Die-cast aluminum (See chapter DC fans - specials) Impeller: GRP1) (PA) - Speed signal Direction of air flow: Exhaust over struts - Go / NoGo alarm Direction of rotation: Counterclockwise, - Alarm with speed limit looking towards rotor - External temperature sensor Connection: Via single wires AWG 22, - Internal temperature sensor TR 64 - PWM control input Highlights: Housing with grounding lug for - Analog control input screw M4 x 8 (Torx) - Moisture protection Weight: 820 g - Salt spray protection - Degree of protection: IP 54 – – – DC centrifugal fans – – DC axial fans – Material: 530 312 24 16...28 65 7.3 40 DV 6448 530 312 48 28...60 65 7.3 40 rpm-1 °C Hours Hours 4 300 -20...+75 90 000 / 35 000 152 500 4 300 -20...+75 90 000 / 35 000 152 500 DC fans - specials DV 6424 dB(A) Bel(A) Curve VDC Life expectancy L10IPC (40 °C) see page 17 VDC Service life L10 (Tmax) ebm-papst standard cfm Service life L10 (40 °C) ebm-papst standard m3/h Temperature range Power consumption Type Nominal data Nominal speed Sintec sleeve bearings Ball bearings Voltage range Sound power level Nominal voltage Watts Air flow / Air flow Series DV 6400 Sound pressure level 1) Fiberglass-reinforced plastic ¿ ¿ Finger guards from p. 242 Accessories (7.5 deep ) 73 Representatives Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions ted 2016-01 Tin-p la AC centrifugal fans AC axial fans ACmaxx / EC fans Subject to change Max. 680 m /h DC diagonal fan 3 172 x 160 x 51 mm – Possible special versions: Housing: Die-cast aluminum (See chapter DC fans - specials) Impeller: GRP1) (PA) - Speed signal Direction of air flow: Exhaust over struts - Go / NoGo alarm Direction of rotation: Counterclockwise, - Alarm with speed limit looking towards rotor - External temperature sensor Connection: Via single wires AWG 22, - Internal temperature sensor TR 64 - PWM control input Highlights: 3-phase fan drive with very - Analog control input smooth operation and high effi- Moisture protection ciency. Housing with grounding - Salt spray protection lug for screw M4 x 8 (Torx) - Degree of protection: IP 54 Weight: 820 g - Reversible direction of rotation – Material: – – – – – 24 16...28 Min 100 59 680 400 24 16...28 48 40...55 DV 6424 TD... Max Min DV 6448 TD... Max 100 59 680 400 rpm-1 °C Hours Hours -20...+60 65 000 / 40 000 110 000 -20...+60 65 000 / 40 000 110 000 -20...+60 65 000 / 40 000 110 000 71 7.9 91 5 500 29 — 2 800 71 7.9 91 5 500 29 — 2 800 71 7.9 86 5 500 Curve 400 Watts Life expectancy L10IPC (40 °C) see page 17 680 / Service life L10 (Tmax) ebm-papst standard DV 6424 TD dB(A) Bel(A) Service life L10 (40 °C) ebm-papst standard VDC Temperature range VDC Nominal speed Voltage range cfm Power consumption* Nominal voltage m3/h Sintec sleeve bearings Ball bearings Air flow Type Nominal data Sound power level Air flow Series DV 6400 TD TURBOFAN Sound pressure level 1) Fiberglass-reinforced plastic ¡ ¿ ¡ ¿ ¡ Subject to change Models DV 6424 TD... and DV 6448 TD... are available in customer-specific, custom-developed variants only. The figures indicated are technically feasible benchmark values. The fans can be specially adapted to your application with signal outputs and control inputs. For details of the technical possibilities, refer to the chapters on the sensor signal, alarm signal and control inputs beginning on page 165. * Power consumption at free air flow. These values can be significantly higher in the operating point. Tin-p la 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 74 Finger guards from p. 242 ted (7.5 deep ) 930 m /h Information Max. DC axial fans 3 172 x 160 x 51 mm – Possible special versions: Housing: Die-cast aluminum (See chapter DC fans - specials) Impeller: GRP1) (PA) - Speed signal Direction of air flow: Exhaust over struts - Go / NoGo alarm Direction of rotation: Counterclockwise, - Alarm with speed limit looking towards rotor - External temperature sensor Connection: Via single wires AWG 18, 20 or - Internal temperature sensor AWG 22, TR 64, speed signal - PWM control input (standard) and control input AWG 22 - Analog control input Highlights: Highly efficient and smoothly - Multi-option control input operating 3-phase fan drive - Moisture protection Housing with grounding lug for - Salt spray protection screw M4 x 8 (Torx) - Degree of protection: IP 54 Weight: 910 g – – – DC centrifugal fans – – DC axial fans – Material: 710 418 24 16...36 69 7.9 67 6318/2 TDH4P-007 930 546 48 36...72 75 8.4 150 °C Hours Hours 7 000 -20...+75 62 500 / 25 000 105 000 9 200 -20...+75 52 500 / 20 000 87 500 ¿ ¡ AC centrifugal fans AC axial fans ACmaxx / EC fans Speed control range from 1000 rpm-1 up to maximum nominal speed. Standstill at 0% PWM, maximum speed if control cable is interrupted. * Power consumption at free air flow. These values can be significantly higher in the operating point. Finger guards from p. 242 Accessories Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions ted 7.6 d eep 75 Representatives Tin-p la 2016-01 Subject to change rpm-1 DC fans - specials 6314/2 TDHHP-015 dB(A) Bel(A) Curve VDC Life expectancy L10IPC (40 °C) see page 17 VDC Service life L10 (Tmax) ebm-papst standard cfm Service life L10 (40 °C) ebm-papst standard m3/h Temperature range Power consumption* Type Nominal data Nominal speed Sintec sleeve bearings Ball bearings Voltage range Sound power level Nominal voltage Watts Air flow / Air flow Series 6300 TD Sound pressure level 1) Fiberglass-reinforced plastic Max. 685 m /h DC axial fans 3 Ø 172 x 51 mm – Possible special versions: Housing: Die-cast aluminum (See chapter DC fans - specials) Impeller: GRP1) (PA) - Speed signal Direction of air flow: Exhaust over struts - Go / NoGo alarm Direction of rotation: Counterclockwise, - Alarm with speed limit looking towards rotor - External temperature sensor Connection: (+) and GND AWG 20, UL 1007, - Internal temperature sensor TR 64; speed signal and alarm - PWM control input (standard) signal: AWG 22, UL 1007, TR 64 - Analog control input Highlights: Highly efficient and smoothly - Multi-option control input operating 3-phase fan drive - Moisture protection Housing with grounding lug for - Salt spray protection screw M4 x 8 (Torx) - Degree of protection: IP 54 / IP 68 Weight: 850 g – Material: – – – – – 24 16…32 - 403 48 36…60 - Subject to change °C Hours Hours 6.9 30 4000 -20…+70 80 000 / 40 000 135 000 7.5 53 5000 -20…+70 77 500 / 40 000 130 000 Speed control range from 1000 rpm-1 up to maximum nominal speed. Standstill at 0% PWM, maximum speed if control cable is interrupted. Tin-plated 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 76 Finger guards from p. 242 Ø 162+0,15 -0,3 Ø 166 Curve 318 685 rpm-1 Life expectancy L10IPC (40 °C) see page 17 540 6318 N/2 H3P Watts Service life L10 (Tmax) ebm-papst standard 6314 N/2 HHP / dB(A) Bel(A) Service life L10 (40 °C) ebm-papst standard VDC Temperature range VDC Nominal speed Voltage range cfm Power consumption Nominal voltage m3/h Sintec sleeve bearings Ball bearings Air flow Type Nominal data Sound power level Air flow Series 6300 N Sound pressure level 1) Fiberglass-reinforced plastic ¿ ¡ 1030 m /h Information Max. DC axial fans 3 Ø 172 x 51 mm – Possible special versions: Housing: Die-cast aluminum (See chapter DC fans - specials) Impeller: GRP1) (PA) - Speed signal Direction of air flow: Exhaust over struts - Go / NoGo alarm Direction of rotation: Counterclockwise, - Alarm with speed limit looking towards rotor - External temperature sensor Connection: AWG 18, 20 UL 1007, TR 64, - Internal temperature sensor speed and alarm signals: - PWM control input (standard) AWG 22, UL 1007, TR 64 - Analog control input Highlights: Highly efficient and smoothly - Multi-option control input operating 3-phase fan drive - Moisture protection Housing with grounding lugfor - Salt spray protection screw M4 x 8 (Torx) - Degree of protection: IP 54 Weight: 850 g – – – DC centrifugal fans – – DC axial fans – Material: cfm VDC VDC 6314 N/2 TDHHP 970 571 24 16…36 - 8.3 135 7200 -20…+70 62,500 / 32,500 105,000 6318 N/2 TDH3P 1030 606 48 36…72 83 8.4 152 7500 -20…+70 60,000 / 30,000 102,500 Hours Hours ¿ ¡ AC centrifugal fans AC axial fans ACmaxx / EC fans Speed control range from 1000 rpm-1 up to maximum nominal speed. Standstill at 0% PWM, maximum speed if control cable is interrupted. * Power consumption at free air flow. These values can be significantly higher in the operating point. Finger guards from p. 242 Accessories Ø 162+0,15 -0,3 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Ø 166 77 Representatives Subject to change dB(A) Bel(A) 2016-01 Type DC fans - specials m3/h Nominal data Curve Life expectancy L10IPC (40 °C) see page 17 Service life L10 (Tmax) ebm-papst standard Service life L10 (40 °C) ebm-papst standard Temperature range Power consumption* Nominal speed Sintec sleeve bearings Ball bearings Sound power level °C Voltage range rpm-1 Nominal voltage Watts Air flow / Air flow Series 6300 NTD Sound pressure level 1) Fiberglass-reinforced plastic Max. 545 m /h DC axial fans 3 Ø 172 x 51 mm – Material: – – – – – Housing: Die-cast aluminum Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Counterclockwise, looking towards rotor Connection: Via single wires AWG 22, TR 64 Highlights: Housing with grounding lug for screw M4 x 8 (Torx) Weight: 825 g – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - Alarm with speed limit - External temperature sensor - Internal temperature sensor - PWM control input (standard) - Analog control input - Moisture protection - Salt spray protection - Degree of protection: IP 54 -20...+75 82 500 / 32 500 140 000 4 400 -20...+70 80 000 / 40 000 135 000 31 5 000 -20...+65 77 500 / 42 500 130 000 32 5 000 -20...+65 77 500 / 42 500 130 000 VDC VDC 6314/2 MP 395 232 24 16...30 51 6.0 14 6314/2 NP 470 276 24 16...30 56 6.5 23 6314/2 HP 545 320 24 16...30 58 6.9 6318/2 HP 545 320 48 36...72 58 6.9 Subject to change Speed control range from 700 rpm-1 up to maximum nominal speed. Standstill at 0% PWM, maximum speed if control cable is interrupted. * Power consumption at free air flow. These values can be significantly higher in the operating point. 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LwA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Finger guards from p. 242 Tin-p la ted 7.6 d eep Curve 3 700 cfm 78 Life expectancy L10IPC (40 °C) see page 17 Hours m3/h dB(A) Bel(A) Service life L10 (Tmax) ebm-papst standard Hours Type Nominal data Service life L10 (40 °C) ebm-papst standard Temperature range Power consumption* °C Voltage range rpm-1 Nominal voltage Nominal speed Sintec sleeve bearings Ball bearings Watts Air flow Sound power level / Air flow Series 6300 Sound pressure level 1) Fiberglass-reinforced plastic ¿ ¡ ¬ ¬ 930 m /h Information Max. DC axial fans 3 Ø 172 x 51 mm – Possible special versions: Housing: Die-cast aluminum (See chapter DC fans - specials) Impeller: GRP1) (PA) - Speed signal Direction of air flow: Exhaust over struts - Go / NoGo alarm Direction of rotation: Counterclockwise, - Alarm with speed limit looking towards rotor - External temperature sensor Connection: Via single wires AWG 18, 20 or - Internal temperature sensor AWG 22, TR 64, speed signal - PWM control input (standard) and control input AWG 22 - Analog control input Highlights: Highly efficient and smoothly - Multi-option control input operating 3-phase fan drive - Moisture protection Housing with grounding lug for - Salt spray protection screw M4 x 8 (Torx) - Degree of protection: IP 54 Weight: 910 g – – – DC centrifugal fans – – DC axial fans – Material: Hours 7.3 40 5 500 -20...+70 75 000 / 37 500 127 500 60 7.3 42 5 500 -20...+65 75 000 / 42 500 127 500 16...36 60 7.3 40 5 500 -20...+75 75 000 / 30 000 127 500 16...36 69 7.9 67 7 000 -20...+75 62 500 / 25 000 105 000 16...36 75 8.4 150 9 200 -20...+75 52 500 / 20 000 87 500 Air flow Nominal voltage Voltage range cfm VDC VDC 6312/2 TDHP 600 353 12 8...16 60 6314/2 TDHP-298 600 353 24 16...30 6314/2 TDHP 600 353 24 6314/2 TDHHP 710 418 24 6314/2 TDH4P 930 545 24 6318/2 TDHP-299 600 353 48 36...60 60 7.3 42 5 500 -20...+65 75 000 / 42 500 127 500 6318/2 TDHP 600 353 48 36...72 60 7.3 40 5 500 -20...+75 75 000 / 30 000 127 500 6318/2 TDHHP 710 418 48 36...72 69 7.9 67 7 000 -20...+75 62 500 / 25 000 105 000 6318/2 TDH4P 930 545 48 36...72 75 8.4 150 9 200 -20...+75 52 500 / 20 000 87 500 dB(A) Bel(A) / DC fans - specials Hours m3/h ¡ ¿ ¡ ¬ ƒ ACmaxx / EC fans °C Type Nominal data Curve Life expectancy L10IPC (40 °C) see page 17 Service life L10 (Tmax) ebm-papst standard Temperature range Service life L10 (40 °C) ebm-papst standard Nominal speed Power consumption* Sintec sleeve bearings Ball bearings rpm-1 Sound power level Watts Air flow Series 6300 TD Sound pressure level 1) Fiberglass-reinforced plastic ¿ ¡ ¬ √ Subject to change AC centrifugal fans AC axial fans Speed control range from 1000 rpm-1 up to maximum nominal speed. Standstill at 0% PWM, maximum speed if control cable is interrupted. * Power consumption at free air flow. These values can be significantly higher in the operating point. 6318/2 TDHHP 115 6318/2 TDH4P 270 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LwA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Finger guards from p. 242 Tin-p la ted 7.6 d eep 79 Representatives optimum operating range (W) 2016-01 Fan type Accessories * Power consumption – in operation Max. DC diagonal fan 1100 m /h 3 Ø 172 x 51 mm – Possible special versions: Housing: Die-cast aluminum (See chapter DC fans - specials) Impeller: GRP1) (PA) - Speed signal Direction of air flow: Exhaust over struts - Go / NoGo alarm Direction of rotation: Counterclockwise, - Alarm with speed limit looking towards rotor - External temperature sensor Connection: (+) and GND: AWG 18, UL 1007, - Internal temperature sensor TR 64; speed and alarm signal: - PWM control input (standard) AWG 22, UL 1007, TR 64 - Analog control input Highlights: Highly efficient and smoothly - Multi-option control input operating 3-phase fan drive - Moisture protection Housing with grounding lugfor - Salt spray protection screw M4 x 8 (Torx) - Degree of protection: IP 54 Weight: 1050 g – Material: – – – – – Life expectancy L10IPC (40 °C) see page 17 Service life L10 (Tmax) ebm-papst standard Temperature range Service life L10 (40 °C) ebm-papst standard Nominal speed Power consumption Sintec sleeve bearings Ball bearings Sound power level m3/h cfm VDC VDC DV 6318/2 TDHP* 630 371 48 36…72 68 7.6 75 4000 -20…+65 70 000 / 40 000 117 500 DV 6318/2 TDHHP* 770 453 48 36…72 73 8.0 135 4900 -20…+65 60 000 / 32 500 102 500 DV 6318/2 TDH4P 1050 617 48 36…72 77 8.7 300 6500 -20…+65 50 000 / 27 500 85 000 DV 6318/2 TDH5P** 1100 647 48 36…72 79 8.9 360 6800 -20…+65 40 000 / 22 500 67 500 Nominal data dB(A) Bel(A) / Watts Hours Curve Type Air flow Voltage range °C Nominal voltage rpm-1 Air flow Series DV 6300 TD Sound pressure level 1) Fiberglass-reinforced plastic Hours ¿ ¡ ¬ √ Subject to change Speed control range from 1000 rpm-1 up to maximum nominal speed. Standstill at 0% PWM, maximum speed if control cable is interrupted. The fan has an acceleration of up to 30% that produces a smoother curve. * On request ** Rotor protrusion a = 3 mm n rpm-1 Ped W LwA dB(A) L10 (40 °C) L10 (65 °C) L10IPC (40 °C) 4000 3835 3815 3930 4240 65,5 64,5 64,5 65 66 79 78 76 76 79 70 000 72 500 75 000 77 500 77 500 40 000 40 000 42 500 42 500 42 500 117 500 122 500 127 500 130 000 130 000 4900 4690 4670 4870 5190 120 119 119 120 121 83 82 80 81 85 60 000 67 500 72 500 75 000 75 000 32 500 37 500 40 000 42 500 42 500 102 500 115 000 122 500 127 500 127 500 n rpm-1 Ped W LwA dB(A) L10 (40 °C) L10 (65 °C) L10IPC (40 °C) 6500 6230 6200 6450 6900 280 275 280 281 283 90 89 88 88 92,5 50 000 62 500 70 000 72 500 72 500 27 500 35 000 40 000 40 000 40 000 85 000 105 000 117 500 122 500 122 500 6950 6720 6630 6850 7300 345 345 345 345 345 92 91 89,5 89 94 40 000 57 500 62 500 67 500 72 500 22 500 32 500 35 000 37 500 40 000 67 500 97 500 105 000 115 000 122 500 Tin-plated 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 80 Finger guards from p. 242 9.0 deep Information Max. DC axial fans 1220 m /h 3 220 x 200 x 51 mm – Possible special versions: Housing: Die-cast aluminum (See chapter DC fans - specials) Impeller: GRP1) (PA) - Speed signal Direction of air flow: Exhaust over struts - Go / NoGo alarm Direction of rotation: Counterclockwise, - Alarm with speed limit looking towards rotor - External temperature sensor Connection: Via single wires AWG 18, 20 or - Internal temperature sensor AWG 22, TR 64, speed signal - PWM control input and control input AWG 22 - Analog control input Highlights: Highly efficient and smoothly - Multi-option control input operating 3-phase fan drive - Moisture protection Housing with grounding lug - Salt spray protection for screw M4 x 8 (Torx) - Degree of protection: IP 54 Weight: 1000 g – – – DC centrifugal fans – – DC axial fans – Material: cfm VDC VDC 2214 F/2 TDHO 790 465 24 16...30 62 7.1 35 4250 -20...+75 90 000 / 42 500 152 500 2214 F/2 TDHHO 940 553 24 16...36 66 7.4 48 5000 -20...+70 85 000 / 42 500 142 500 2218 F/2 TDHO 790 465 48 36...57 62 7.1 35 4250 -20...+75 90 000 / 42 500 152 500 2218 F/2 TDHHO 940 553 48 36...72 66 7.4 48 5000 -20...+70 85 000 / 42 500 142 500 2218 F/2 TDH4P 1220 718 48 36...72 72 8.2 103 6500 -20...+65 70 000 / 40 000 117 500 dB(A) Bel(A) Hours Hours DC fans - specials m3/h ¿ ¡ ¿ ¡ ¬ ACmaxx / EC fans Type Subject to change Finger guards from p. 242 Tin-p la ted 7.6 d eep 81 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Accessories AC centrifugal fans AC axial fans Speed control range from 1000 rpm-1 up to maximum nominal speed. Standstill at 0% PWM, Type O: standstill if control wire is interrupted; Type P: maximum speed if control wire is interrupted. * Power consumption at free air flow. These values can be significantly higher in the operating point. Representatives Nominal data Curve Life expectancy L10IPC (40 °C) see page 17 Service life L10 (Tmax) ebm-papst standard Service life L10 (40 °C) ebm-papst standard Temperature range Power consumption* Nominal speed Sintec sleeve bearings Ball bearings Sound power level °C Voltage range rpm-1 Nominal voltage Watts Air flow / Air flow Series 2200 FTD Sound pressure level 1) Fiberglass-reinforced plastic Max. 1245 m /h DC diagonal module 3 225 x 80 mm – Material: Housing and support bracket: Fiberglass-reinforced plastic (PA6) Impeller: Fiberglass-reinforced plastic (PA6) Rotor: Painted black Number of blades: 7 Direction of air flow: "V" Direction of rotation: Clockwise, looking towards rotor A C IP 44, B D IP 20, depending on installation and position Degree of protection: Insulation class: "B" Installation position: Any Condensation drainage holes: A C none, B D seen on rotor Mode of operation: Continuous operation (S1) Bearings: Maintenance-free ball bearings Power consumption Input current Sound power level Admissible amb. temp. Weight VDC m3/h rpm-1 W A dB(A) °C kg A 24 16...28 1020 3 400 95 4.7 76 -25...+60 1.8 p. 262 / J5) M1G 074-BF B 24 16...28 1045 3 500 110 5.4 77 -25...+70 1.7 p. 262 / J5) K1G 200-AD49-04 M1G 074-BF C 48 36...57 1095 3 650 120 3.4 77 -25...+60 1.8 p. 262 / J5) K1G 200-AD37-02 M1G 074-BF D 48 36...57 1245 4 140 183 5.6 81 -25...+70 1.7 p. 262 / J5) Nominal voltage Curve Type Motor K1G 200-AD65-04 M1G 074-BF K1G 200-AD31-02 Technical features and connection diagram Nominal speed VDC Nominal data Nominal voltage range Air flow – – – – – – – – – n rpm-1 in wg Curves: Pa Subject to change 1 3400 95 4.70 76 2 3410 116 5.61 74 A 3 3410 119 5.75 74 A 4 3410 117 5.62 76 B B 1 3500 110 5.40 77 A B 2 3510 127 6.24 75 B 3 3510 129 6.31 75 B 4 3510 125 6.15 76 C 1 3650 120 3.40 77 C 2 3645 141 3.90 75 C 3 3640 145 3.99 76 C 4 3645 141 3.88 80 D 1 4140 183 5.60 81 D 2 4080 212 6.46 79 D 3 4060 213 6.52 79 D 4 4105 211 6.43 80 2 1.5 C 1 300 0.5 200 100 Pfs 0 qv 100 200 200 300 400 400 600 500 800 600 1000 700 1200 cfm m³/h Air performance measured according to: ISO 5801. Installation category A, without contact protection. Suction-side noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 2016-01 L WA dB(A) A 400 82 I A A D 500 Ped W Information DC centrifugal fans DC fans - specials ACmaxx / EC fans Ø276 ±0.5 225 Ø4.6 (4x) 80 ±1 AC axial fans Ø288 6 4x90° AC centrifugal fans 45° 0+ 20 .5 67 Ø2 35 0 ±1 Accessories 85 6 "V" Cable assignment: Red = UN Yellow = 0-10 VDC White = tach output Blue = GND Connection diagrams P. 262 83 Representatives AWG 20 cable, 4x crimped splices 2016-01 – – – – See connection diagram p. 262 Immunity to interference according to EN 61000-6-2 (industrial environment) Interference emission according to EN 55022 (Class B) Cable exit: Lateral Protection class: I (with customer connection to grounding conductor) Conformity with standard(s): EN 60335-1 A C UL 1004-1, CSA C22.2 no. 77 Approvals B D EAC, UL 1004-1, CSA C22.2 no. 77 DC axial fans – Technical features: – EMC: Max. 1650 m /h DC diagonal module 3 225 x 89 mm – Material: Power consumption Input current Sound power level Admissible amb. temp. Weight VDC m3/h rpm-1 W A dB(A) °C kg A 24 16...28 1240 4120 170 7.0 80 -25...+60 2.3 p. 262 / J5) M3G 074-CF B 24 16...28 1445 4830 275 11.5 84 -25...+60 2.3 p. 262 / J5) K3G 200-BD64-04 M3G 074-CF C 48 36...57 1475 4875 275 5.8 85 -25...+60 2.3 p. 262 / J5) K3G 200-BDA8-02 M3G 074-CF D 48 36...57 1650 5470 400 8.4 88 -25...+60 2.3 p. 262 / J5) Nominal voltage Curve Type Motor K3G 200-BD46-04 M3G 074-CF K3G 200-BD44-02 Technical features and connection diagram Nominal speed VDC Nominal data Nominal voltage range Air flow – – – – – – – – – Housing and support bracket: Plastic (PA) Impeller: Plastic (PA) Rotor: Painted black Number of blades: 7 Direction of air flow: "V" Direction of rotation: Clockwise, looking towards rotor A C IP 44, B D IP 20, depending on installation and position Degree of protection: Insulation class: "B" Installation position: Any Condensation drainage holes: A C none, B D seen on rotor Mode of operation: Continuous operation (S1) Bearings: Maintenance-free ball bearings Pa Curves: in wg Subject to change n rpm-1 Ped W I A L WA dB(A) D 3 800 B C 600 2 A 1 4120 170 7.00* 80 A 2 4025 180 7.52* 77 A 3 4005 187 7.80* 76 A 4 4045 187 7.78* 78 B 1 4830 275 11.50* 84 B 2 4720 294 12.24* 81 B 3 4685 299 12.48* 80 B 4 4715 295 12.30* 83 C 1 4875 275 5.80* 85 C 2 4795 300 6.27* 81 C 3 4755 307 6.41* 80 C 4 4780 304 6.35* 82 D 1 5470 400 8.40* 88 D 2 5365 426 8.89* 85 D 3 5310 438 9.17* 83 D 4 5355 431 9.01* 87 1 400 A 200 * Current measured at nominal voltage. Pfs 0 qv 200 400 400 600 800 800 1200 1000 cfm 1600 m³/h 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Suction-side noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 84 Information See connection diagram p. 262 Immunity to interference according to EN 61000-6-2 (industrial environment) Interference emission according to EN 55022 (Class B, household environment) – Cable exit: Lateral – Conformity with standard(s): EN 60335-1 – Approvals: (24 V) EAC (48 V) EAC, CCC ACmaxx / EC fans DC fans - specials DC centrifugal fans DC axial fans – Technical features: – EMC (48 V): 225 ±0.5 Ø4.6 ±0.2 (4x) 219 ±0.5 83 ±1 Ø2 76 ± AC axial fans 6 45° 45° 0.5 Mounting dimensions Ø 27 AC centrifugal fans 6 ±0.5 Ø2 69 ±0 "V" Accessories 500 +20 85 ±10 8 .5 Cable assignment: Red = UN Yellow = 0-10 VDC White = tach output Blue = GND 85 Representatives Connection diagrams P. 262 2016-01 PVC AWG 16 cable 4x crimped ferrules Max. 2070 m /h DC axial fans 3 Ø 250 mm – Material: Power consumption Input current Max. back-pressure Admissible amb. temp. Motor VDC m3/h rpm-1 W A Pa °C W1G250-HJ87 -02 M1G 074-BF A 24 16-28 2070 3090 120 7.00 150 -25...+60 p. 258 / E) W1G250-HJ63 -02 M1G 074-BF B 48 36-57 2070 3090 120 3.40 150 -25...+60 p. 258 / E) Nominal voltage Technical features and connection diagram Nominal speed Type Nominal voltage range VDC Curve Nominal data Number of blades: Direction of air flow: Direction of rotation: Insulation class: Installation position: Any Condensation drainage holes: On rotor side Mode of operation: Continuous operation (S1) Bearings: Maintenance-free ball bearings Air flow – – – – – – – – Fan housing: Die-cast aluminum Blades: Plastic (PP) Rotor: Thick-film passivated 7 "V" Counterclockwise, looking towards rotor "B" Pa Curves: in H2O Subject to change 160 0,6 A 0,5 0,4 0,3 0,2 2 0,1 40 pfs 20 0 200 400 400 600 800 800 1200 1000 1600 1 1200 cfm 2000 m3/h 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Suction-side noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 86 L WA dB(A) A 1 3090 120 6.80 74 A 2 2950 124 7.10 73 A 3 2820 127 7.43 73 A 4 2730 130 7.80 78 B 1 3090 120 3.40 74 B 2 2950 124 3.55 73 B 3 2820 127 3.74 73 B 4 2730 130 3.90 78 3 60 qV I A 4 120 80 Ped W B 140 100 n rpm-1 Information See connection diagram p. 258 Interference emission acc. to EN 55022 (Class B) Immunity to interference acc. to EN 61000-6-2 (industrial environment) – Electrical hookup: Via terminal strip – Protection class: I – Conformity with standard(s): EN 60950-1 ACmaxx / EC fans DC fans - specials DC centrifugal fans DC axial fans – Technical features: – EMC: Accessories AC centrifugal fans AC axial fans For self-tapping M6 screws Connection diagrams P. 258 (1) Control input (2) Speed monitoring 87 Representatives Finger guards from p. 245 "V" 2016-01 For self-tapping M5 screws Max. DC axial fans – HyBlade® 2345 m /h 3 Ø 300 mm – Material: Power consumption Input current Max. back-pressure Admissible amb. temp. Motor VDC m3/h rpm-1 W A Pa °C *1G 300 M1G 074-CF A 24 16-28 2320 1830 80 3.80 100 -25..+60 p. 262 / J5) *1G 300 M1G 074-CF B 48 36-57 2345 1830 80 1.90 100 -25..+60 p. 262 / J5) Technical features and connection diagram Nominal speed Type Nominal voltage range Nominal data Nominal voltage VDC Curve Air flow – – – – – – – – – Finger guard: Steel, phosphated and coated in black plastic Fan housing: Sheet steel, pre-galvanized and coated in black plastic Blades: Plastic (PP) Rotor: Painted black Number of blades: 5 Direction of air flow: "V" Direction of rotation: Counterclockwise, looking towards rotor Degree of protection: IP 42 Insulation class: "B" Installation position: Any Condensation drainage holes: None Mode of operation: Continuous operation (S1) Bearings: Maintenance-free ball bearings Pa Curves: in H2O Subject to change n rpm-1 Ped W I A L WA dB(A) 100 0,4 110 A 90 B 4 4 A 1 1810 80 3.80 67 A 2 1730 86 4.03 67 A 3 1690 87 4.10 66 A 4 1635 89 4.21 70 B 1 1870 87 2.00 68 B 2 1805 90 2.10 67 B 3 1765 91 2.13 67 B 4 1695 92 2.19 69 0,3 80 3 70 60 0,2 50 3 2 40 30 0,1 2 20 pfs 10 0 qV 200 200 400 400 600 600 800 800 1000 1200 1000 1200 1400 1600 1800 2000 2200 1 cfm m3/h 2016-01 Air performance measured according to: ISO 5801, installation category A, in ebm-papst full nozzle without contact protection. Suction-side noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 88 Information With finger guard for short nozzle kg "V" A1G 300-AC19 -54 1.8 W1G 300-DC19 -54 3.8 S1G 300-AC19 -54 2.8 "V" A1G 300-AC33 -54 1.8 W1G 300-DC33 -54 3.8 S1G 300-AC33 -54 3.1 DC axial fans AC axial fans 45° Ø300 ±1 31 AC centrifugal fans Ø58±0.15 85±10 6 450 +20 Ø92 "V" Ø380 15° Ø9 (6x) 57.5 ±3 M4 (4x) 90° 75 80 11 DC centrifugal fans Max. clearance for screw 6 mm A1G 300 79±5 ACmaxx / EC fans "V" kg DC fans - specials Weight with finger guard for short nozzle "V" With full round nozzle PVC AWG 20 cable, 4x crimped splices 25±3 (6 60 ° W1G 300 Connection diagrams P. 262 Accessories 4.3 29±5 S1G 300 89 2016-01 Ø326 Ø397 Ø300 ±1 Ø329.6 Ø360 x) 4.5 57.2 Representatives kg Weight with full round nozzle "V" without attachments Weight without attachments See connection diagram p. 262 Interference emission acc. to EN 55022 (Class B) Immunity to interference acc. to EN 61000-6-2 (industrial environment) – Cable exit: Lateral – Conformity with standard(s): EN 60950-1, UL 1004-1, CSA C22.2 no. 100 – Approvals: GOST, UL Airflow direction – Technical features: – EMC: 2016-01 90