X96012 ® Universal Sensor Conditioner with Dual Look Up Table Memory and DACs Data Sheet March 10, 2005 FEATURES • Two Programmable Current Generators —±3.2 mA max. —8-bit (256 Step) Resolution —Internally Programmable full scale Current Outputs —External Resistor Pin to set full scale Current Outputs • Integrated 8-bit A/D Converter • Internal Voltage Reference with Output/Input • Temperature Compensation —Internal or External Sensor —-40°C to +100°C Range —2.2°C / step resolution —EEPROM Look-up Tables • Hot Pluggable • 2176-bit EEPROM —17 Pages —16 Bytes per Page • Write Protection Circuitry —Intersil BlockLock™ —Logic Controlled Protection —2-wire Bus with 3 Slave Address Bits • 3V to 5.5V, Single Supply Operation • Package —14-Lead TSSOP APPLICATIONS • PIN Diode Bias Control • RF PA Bias Control • Temperature Compensated Process Control • Laser Diode Bias Control • • • • • • • • FN8216.0 Fan Control Motor Control Sensor Signal Conditioning Data Aquisition Applications Gain vs. Temperature Control High Power Audio Open Loop Temperature Compensation Close Loop Current, Voltage, Pressure, Temperature, Speed, Position Programmable Voltage sources, electronic loads, output amplifiers, or function generator DESCRIPTION The X96012 is a highly integrated bias controller which incorporates two digitally controlled Programmable Current Generators, temperature compensation with dedicated look-up tables, and supplementary EEPROM array. All functions of the device are controlled via a 2wire digital serial interface. Two temperature compensated Programmable Current Generators, vary the output current with temperature according to the contents of the associated nonvolatile look-up table. The look-up table may be programmed with arbitrary data by the user, via the 2wire serial port, and either an internal or external temperature sensor may be used to control the output current response. The integrated General Purpose EEPROM is included for product data storage. BLOCK DIAGRAM Voltage Reference VRef R2 Mux Look-up Table 2 Mux DAC 2 I2 Mux Look-up Table 1 Mux DAC 1 I1 ADC VSense Temperature Sensor SDA SCL WP A2, A1, A0 1 Control & Status 2-Wire Interface R1 General Purpose Memory CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures. 1-888-INTERSIL or 1-888-352-6832 | Intersil (and design) is a registered trademark of Intersil Americas Inc. Copyright Intersil Americas Inc. 2005. All Rights Reserved All other trademarks mentioned are the property of their respective owners. X96012 PIN CONFIGURATION A0 A1 A2 Vcc WP SCL SDA 1 2 3 4 5 6 7 14 13 12 11 10 9 8 I2 VRef VSense Vss R2 R1 I1 TSSOP 14L ORDERING INFORMATION Part Number Temperature Range Package X96012V14I I = -40 to 100°C 14-Lead TSSOP 2 FN8216.0 March 10, 2005 X96012 PIN ASSIGNMENTS TSSOP Pin Pin Name Pin Description 1 A0 Device Address Select Pin 0. This pin determines the LSB of the device address required to communicate using the 2-wire interface. The A0 pin has an on-chip pull-down resistor. 2 A1 Device Address Select Pin 1. This pin determines the intermediate bit of the device address required to communicate using the 2-wire interface. The A1 pin has an on-chip pull-down resistor. 3 A2 Device Address Select Pin 2. This pin determines the MSB of the device address required to communicate using the 2-wire interface. The A2 pin has an on-chip pull-down resistor. 4 Vcc Supply Voltage. 5 WP Write Protect Control Pin. This pin is a CMOS compatible input. When LOW, Write Protection is enabled preventing any “Write” operation. When HIGH, various areas of the memory can be protected using the Block Lock bits BL1 and BL0. The WP pin has an on-chip pull-down resistor, which enables the Write Protection when this pin is left floating. 6 SCL Serial Clock. This is a TTL compatible input pin. This input is the 2-wire interface clock controlling data input and output at the SDA pin. 7 SDA Serial Data. This pin is the 2-wire interface data into or out of the device. It is TTL compatible when used as an input, and it is Open Drain when used as an output. This pin requires an external pull up resistor. 8 I1 Current Generator 1 Output. This pin sinks or sources current. The magnitude and direction of the current is fully programmable and adaptive. The resolution is 8 bits. 9 R1 Current Programming Resistor 1. A resistor between this pin and Vss can set the maximum output current available at pin I1. If no resistor is used, the maximum current must be selected using control register bits. 10 R2 Current Programming Resistor 2. A resistor between this pin and Vss can set the maximum output current available at pin I2. If no resistor is used, the maximum current must be selected using control register bits. 11 Vss Ground. 12 VSense Sensor Voltage Input. This voltage input may be used to drive the input of the on-chip A/D converter. 13 VRef Reference Voltage Input or Output. This pin can be configured as either an Input or an Output. As an Input, the voltage at this pin is provided by an external source. As an Output, the voltage at this pin is a buffered output voltage of the on-chip bandgap reference circuit. In both cases, the voltage at this pin is the reference for the A/D converter and the two D/A converters. 14 I2 Current Generator 2 Output. This pin sinks or sources current. The magnitude and direction of the current is fully programmable and adaptive. The resolution is 8 bits. 3 FN8216.0 March 10, 2005 X96012 ABSOLUTE MAXIMUM RATINGS COMMENT All voltages are referred to Vss. Temperature under bias ................... -65°C to +100°C Storage temperature ........................ -65°C to +150°C Voltage on every pin except Vcc ................ -1.0V to +7V Voltage on Vcc Pin .............................................0 to 5.5V D.C. Output Current at pin SDA ...................... 0 to 5 mA D.C. Output Current at pins R1, R2, VRef and VSense.................................... -0.50 to 1 mA D.C. Output Current at pins I1 and I2 ....... -3.5 to +3.5mA Lead temperature (soldering, 10 seconds) ........ 300°C Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only; functional operation of the device (at these or any other conditions above those listed in the operational sections of this specification) is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. RECOMMENDED OPERATING CONDITIONS Parameter Min. -40 0 3 -0.3 Temperature Temperature while writing to memory Voltage on Vcc Pin Voltage on any other Pin Max. +100 +70 5.5 Vcc + 0.3 Units °C °C V V . ELECTRICAL CHARACTERISTICS (Conditions are as follows, unless otherwise specified) All typical values are for 25°C ambient temperature and 5 V at pin Vcc. Maximum and minimum specifications are over the recommended operating conditions. All voltages are referred to the voltage at pin Vss. All bits in control registers are “0”. 255Ω, 0.1%, resistor connected between R1 and Vss, and another between R2 and Vss. 400kHz TTL input at SCL. SDA pulled to Vcc through an external 2kΩ resistor. 2-wire interface in “standby” (see notes 1 and 2 on page 5). WP, A0, A1, and A2 floating. VRef pin unloaded Symbol Parameter Min Typ Max Unit Test Conditions / Notes Iccstby Standby current into Vcc pin 2 mA R1 and R2 floating, VRef unloaded. Iccfull Full operation current into Vcc pin 15 mA 2-wire interface reading from memory, I1 and I2 both connected to Vss, DAC input bytes: FFh, VRef unloaded. Iccwrite Nonvolatile Write current into Vcc pin mA Average from START condition until tWP after the STOP condition WP: Vcc, R1 and R2 floating, VRef unloaded. IPLDN On-chip pull down current at WP, A0, A1, and A2 20 µA V(WP), V(A0), V(A1), and V(A2) from 0V to Vcc VILTTL SCL and SDA, input Low voltage 0.8 V VIHTTL SCL and SDA, input High voltage 2.0 IINTTL SCL and SDA input current -1 10 µA Pin voltage between 0 and Vcc, and SDA as an input. VOLSDA SDA output Low voltage 0 0.4 V I(SDA) = 2 mA IOHSDA SDA output High current 0 100 µA V(SDA) = Vcc VILCMOS WP, A0, A1, and A2 input Low voltage 0 0.2 x Vcc V VIHCMOS WP, A0, A1, and A2 input High voltage 0.8 x Vcc Vcc V 4 4 0 1 V FN8216.0 March 10, 2005 X96012 ELECTRICAL CHARACTERISTICS (CONTINUED) (Conditions are as follows, unless otherwise specified) All typical values are for 25°C ambient temperature and 5 V at pin Vcc. Maximum and minimum specifications are over the recommended operating conditions. All voltages are referred to the voltage at pin Vss. All bits in control registers are “0”. 255Ω, 0.1%, resistor connected between R1 and Vss, and another between R2 and Vss. 400kHz TTL input at SCL. SDA pulled to Vcc through an external 2kΩ resistor. 2-wire interface in “standby” (see notes 1 and 2 on page 5). WP, A0, A1, and A2 floating. VRef pin unloaded Symbol Parameter Min Typ Max Unit Test Conditions / Notes VRefout Output Voltage at VRef at 25°C 1.205 1.21 1.215 V -20 µA ≤ I(VRef) ≤ 20 µA RVref VRef pin input resistance 20 40 kΩ VRM bit = “1”, 25°C TCOref Temperature coefficient of VRef output voltage -100 +100 ppm/° C VRef Range Voltage range when VRef is an input 1 1.3 V See note 3. TSenseRange Temperature sensor range -40 100 °C See note 4. IR Current from pin R1 or R2 to Vss 0 3200 µA VPOR Power-on reset threshold voltage 1.5 2.8 V VccRamp Vcc Ramp Rate 0.2 50 mV / µs VADCOK ADC enable minimum voltage 2.6 2.8 V See note 4 and 5. See Figure 11. Notes: 1. The device goes into Standby: 200 ns after any STOP, except those that initiate a nonvolatile write cycle. It goes into Standby tWC after a STOP that initiates a nonvolatile write cycle. It also goes into Standby 9 clock cycles after any START that is not followed by the correct Slave Address Byte. 2. tWC is the time from a valid STOP condition at the end of a write sequence to the end of the self-timed internal nonvolatile write cycle. It is the minimum cycle time to be allowed for any nonvolatile write by the user, unless Acknowledge Polling is used. 3. For this range of V(VRef) the full scale sink mode current at I1 and I2 follows V(VRef) with a linearity error smaller than 1%. 4. These parameters are periodically sampled and not 100% tested. 5. TCOref = [Max V(VREF) - Min V(VREF)] x 106/(1.21V x 140°C) 5 FN8216.0 March 10, 2005 X96012 D/A CONVERTER CHARACTERISTICS (See pg. 4 for Standard Conditions) Symbol Parameter Min Typ Max Unit I1 or I2 full scale current, with external resistor setting 1.56 1.58 1.6 mA See note 1, 5 3.2 mA See note 1, 4, 6 IFS01 I1 or I2 full scale current, with internal low current setting option 0.3 0.4 0.5 mA IFS10 I1 or I2 full scale current, with internal middle current setting option 0.64 0.85 1.06 mA IFS11 I1 or I2 full scale current, with internal high current setting option 1 1.3 1.6 mA DAC input Byte = FFh, Source or sink mode, V(I1) and V(I2) are Vcc - 1.2V in source mode and 1.2V in sink mode. See notes 2 and 3. OffsetDAC I1 or I2 D/A converter offset error 1 1 LSB FSErrorDAC I1 or I2 D/A converter full scale error -2 2 LSB DNLDAC I1 or I2 D/A converter Differential Nonlinearity -0.5 0.5 LSB INLDAC I1 or I2 D/A converter Integral Nonlinearity with respect to a straight line through 0 and the full scale value -1 1 LSB VISink I1 or I2 Sink Voltage Compliance 1.2 Vcc V See note 5 2.5 Vcc V See note 4, 6 VISource I1 or I2 Source Voltage Compliance 0 Vcc-1.2 V See note 5 0 Vcc-2.5 V See note 4, 6 DAC input byte changing from 00h to FFh and vice versa, V(I1) and V(I2) are Vcc - 1.2V in source mode and 1.2V in sink mode. See note 4. IFS00 IOVER I1 or I2 overshoot on D/A Converter data byte transition 0 µA IUNDER I1 or I2 undershoot on D/A Converter data byte transition 0 µA trDAC I1 or I2 rise time on D/A Converter data byte transition; 10% to 90% 30 µs TCOI1I2 Temperataure coefficient of output current I1 or I2 when using internal resistor setting 5 ±200 ppm/ °C Test Conditions / Notes See Figure 8. Bits I1FSO[1:0] ¦ 002 or Bits I2FSO[1:0] ¦ 002, VRMbit = “1” Notes: 1. DAC input Byte = FFh, Source or sink mode. 2 V(VRef) 2. LSB is defined as divided by the resistance between R1 or R2 to Vss. x 3 255 3. OffsetDAC: The Offset of a DAC is defined as the deviation between the measured and ideal output, when the DAC input is 01h. It is expressed in LSB. FSErrorDAC: The Full Scale Error of a DAC is defined as the deviation between the measured and ideal output, when the input is FFh. It is expressed in LSB. The OffsetDAC is subtracted from the measured value before calculating FSErrorDAC. DNLDAC: The Differential Non-Linearity of a DAC is defined as the deviation between the measured and ideal incremental change in the output of the DAC, when the input changes by one code step. It is expressed in LSB. The measured values are adjusted for Offset and Full Scale Error before calculating DNLDAC. INLDAC: The Integral Non-Linearity of a DAC is defined as the deviation between the measured and ideal transfer curves, after adjusting the measured transfer curve for Offset and Full Scale Error. It is expressed in LSB. [ ] 4. These parameters are periodically sampled and not 100% tested. 5. V(I1) and V(I2) are VCC - 1.2V in source mode and 1.2V in sink mode. In this range the current at I1 or I2 varies < 1%. 6. The maximum current, sink or source, can be set with an external resistor to 3.2 mA with a minimum VCC = 4.5V. The compliance voltage changes to 2.5V from the sourcing rail, and the current variation is < 1%. 6 FN8216.0 March 10, 2005 X96012 A/D CONVERTER CHARACTERISTICS (See pg. 4 for Standard Conditions). Symbol Parameter Min Typ Max Unit Test Conditions / Notes 9 ms Proportional to A/D converter input voltage. This value is maximum at full scale input of A/D converter. ADCfiltOff = “1” kΩ VSense as an input, ADCIN bit = “1” ADCTIME A/D converter conversion time RINADC VSense pin input resistance 100 CINADC VSense pin input capacitance 1 7 pF VSense as an input, ADCIN bit = “1”, Frequency = 1 MHz See note 3. VINADC VSense input signal range 0 V(VRef) V This is the A/D Converter Dynamic Range. ADCIN bit = “1” The ADC is monotonic OffsetADC A/D converter offset error ±1 LSB FSErrorADC A/D converter full scale error ±1 LSB DNLADC A/D Converter Differential Nonlinearity ±0.5 LSB INLADC A/D converter Integral Nonlinearity ±1 LSB TempStepADC Temperature step causing one step increment of ADC output Out25ADC ADC output at 25°C 0.52 0.55 0.58 °C See notes 1 and 2 See note 3 011101012 Notes: 1. “LSB” is defined as V(VRef)/255, “Full Scale” is defined as V(VRef). 0.5 x V(VRef) 2. OffsetADC: For an ideal converter, the first transition of its transfer curve occurs at above zero. Offset error is the 255 amount of deviation between the measured first transition point and the ideal point. 254.5 x V(VRef) FSErrorADC: For an ideal converter, the last transition of its transfer curve occurs at . Full Scale Error is the 255 amount of deviation between the measured last transition point and the ideal point, after subtracting the Offset from the measured curve. DNLADC: DNL is defined as the difference between the ideal and the measured code transitions for successive A/D code outputs expressed in LSBs. The measured transfer curve is adjusted for Offset and Fullscale errors before calculating DNL. INLADC: The deviation of the measured transfer function of an A/D converter from the ideal transfer function. The INL error is also defined as the sum of the DNL errors starting from code 00h to the code where the INL measurement is desired. The measured transfer curve is adjusted for Offset and Fullscale errors before calculating INL. 3. These parameters are periodically sampled and not 100% tested. [ ] [ 7 ] FN8216.0 March 10, 2005 X96012 2-WIRE INTERFACE A.C. CHARACTERISTICS Symbol Max Units Test Conditions / Notes 400 kHz Pulse width Suppression Time at inputs 50 ns See “2-Wire Interface Test Conditions” (below), tAA(4) SCL Low to SDA Data Out Valid 900 ns tBUF(4) Time the bus free before start of new transmission tLOW Clock Low Time fSCL tIN Parameter Min SCL Clock Frequency (4) Typ 1(3) 1300 ns 1.3 1200(3) µs 0.6 1200(3) µs tHIGH Clock High Time tSU:STA Start Condition Setup Time 600 ns tHD:STA Start Condition Hold Time 600 ns tSU:DAT Data In Setup Time 100 ns tHD:DAT Data In Hold Time 0 µs tSU:STO Stop Condition Setup Time 600 ns tDH Data Output Hold Time 50 ns tR (4) tF(4) tSU:WP(4) SDA and SCL Rise Time 20 +0.1Cb(1) 300 ns SDA and SCL Fall Time 20 +0.1Cb(1) 300 ns WP Setup Time 600 ns tHD:WP WP Hold Time 600 ns Cb(4) Capacitive load for each bus line (4) See Figure 1, Figure 2 and Figure 3. 400 pF 2-WIRE INTERFACE TEST CONDITIONS Input Pulse Levels 10 % to 90 % of Vcc Input Rise and Fall Times, between 10% and 90% 10 ns Input and Output Timing Threshold Level 1.4V External Load at pin SDA 2.3kΩ to Vcc and 100 pF to Vss NONVOLATILE WRITE CYCLE TIMING Symbol tWC (2) Parameter Nonvolatile Write Cycle Time Min Typ Max Units Test Conditions / Notes 5 10 ms See Figure 3 Notes: 1. Cb = total capacitance of one bus line (SDA or SCL) in pF. 2. tWC is the time from a valid STOP condition at the end of a write sequence to the end of the self-timed internal nonvolatile write cycle. It is the minimum cycle time to be allowed for any nonvolatile write by the user, unless Acknowledge Polling is used. 3. The minimum frequency requirement applies between a START and a STOP condition. 4. These parameters are periodically sampled and not 100% tested. 8 FN8216.0 March 10, 2005 X96012 TIMING DIAGRAMS Figure 1. Bus Timing tHIGH tF SCL tLOW tR tSU:DAT tSU:STA tHD:DAT tHD:STA SDA IN tSU:STO tAA tDH tBUF SDA OUT Figure 2. WP Pin Timing STOP START SCL Clk 1 SDA IN tSU:WP tHD:WP WP Figure 3. Non-Volatile Write Cycle Timing SCL SDA 8th bit of last byte ACK tWC Stop Condition 9 Start Condition FN8216.0 March 10, 2005 X96012 INTERSIL SENSOR CONDITIONER PRODUCT FAMILY Features/Functions Internal Temperature Sensor External Sensor Input Internal Voltage Reference VREF Input / Ouput General Purpose EEPROM Look Up Table Organization # of DACs FSO Current DAC Setting Resistors Device Title X96010 Sensor Conditioner with Dual Look-Up Table Memory and DACs No Yes Yes Yes No Dual Bank Dual Ext X96011 Temperature Sensor with Look-Up Table Memory and DAC Yes No Yes No No Single Bank Single Int X96012 Universal Sensor Conditioner with Dual Look-Up Table Memory and DACs Yes Yes Yes Yes Yes Dual Bank Dual Ext / Int FSO = Full Scale Output, Ext = External, Int = Internal DEVICE DESCRIPTION The X96012 combines two Programmable Current Generators, and integrated EEPROM with Block Lock™ protection, in one package. The combination of the X96012 functionality and Intersil’s QFN package lowers system cost, increases reliability, and reduces board space requirements. Two on-chip Programmable Current Generators may be independently programmed to either sink or source current. The maximum current generated is determined by using an externally connected programming resistor, or by selecting one of three predefined values. Both current generators have a maximum output of ±3.2 mA, and may be controlled to an absolute resolution of 0.39% (256 steps/8 bit). The contents of the selected LUT row (8-bit wide) drives the input of an 8-bit D/A converter, which generates the output current. All control and setup parameters of the X96012, including the look-up tables, are programmable via the 2-wire serial port. The general purpose memory portion of the device is a CMOS serial EEPROM array with Intersil’s Block LockTM protection. The EEPROM array is internally organized as 272 x 8 bits with 16-Byte pages, and utilizes Intersil’s proprietary Direct WriteTM cells, providing a minimum endurance of 100,000 Page Write cycles and a minimum data retention of 100 years. Both current generators may be driven using an onboard temperature sensor, an external sensor, or Control Registers. The internal temperature sensor operates over a very broad temperature range (-40°C to +100°C). The sensor output (internal or external) drives an 8-bit A/D converter. The six MSBs of the ADC output select one of 64 bytes from each nonvolatile look-up table (LUT). 10 FN8216.0 March 10, 2005 X96012 PRINCIPLES OF OPERATION CONTROL AND STATUS REGISTERS The Control and Status Registers provide the user with a mechanism for changing and reading the value of various parameters of the X96012. The X96012 contains seven Control, one Status, and several Reserved registers, each being one Byte wide (See Figure 4). The Control registers 0 through 6 are located at memory addresses 80h through 86h respectively. The Status register is at memory address 87h, and the Reserved registers at memory address 88h through 8Fh. All bits in Control register 6 always power-up to the logic state “0”. All bits in Control registers 0 through 5 power-up to the logic state value kept in their corresponding nonvolatile memory cells. The nonvolatile bits of a register retain their stored values even when the X96012 is powered down, then powered back up. The nonvolatile bits in Control 0 through Control 5 registers are all preprogrammed to the logic state “0” at the factory. Bits indicated as “Reserved” are ignored when read, and must be written as “0”, if any Write operation is performed to their registers. A detailed description of the function of each of the Control and Status register bits follows: Notice that if the Write Protect (WP) input pin of the X96012 is active (LOW), then any write operation to the memory is inhibited, irrespective of the Block Lock bit settings. VRM: VOLTAGE REFERENCE PIN MODE (NON-VOLATILE) The VRM bit configures the Voltage Reference pin (VRef) as either an input or an output. When the VRM bit is set to “0” (default), the voltage at pin VRef is an output from the X96012’s internal voltage reference. When the VRM bit is set to “1”, the voltage reference for the VRef pin is external. See Figure 5. ADCIN: A/D CONVERTER INPUT SELECT (NON-VOLATILE) The ADCIN bit selects the input of the on-chip A/D converter. When the ADCIN bit is set to “0” (default), the output of the on-chip temperature sensor is the input to the A/D converter. When the ADCIN bit is set to “1”, the input to the A/D converter is the voltage at the VSense pin. See Figure 7. ADCFILTOFF: ADC FILTERING CONTROL (NONVOLATILE) When this bit is“1”, the status register at 87h is updated after every conversion of the ADC. When this bit is “0” (default), the status register is updated after four consecutive conversions with the same result, on the 6 MSBs. Control Register 0 This register is accessed by performing a Read or Write operation to address 80h of memory. BL1, BL0: BLOCK LOCK PROTECTION BITS (NONVOLATILE) BL1 BL0 These two bits are used to inhibit any write operation to certain addresses within the memory array. The protected region of memory is determined by the values of the two bits as shown in the table below: Protected Addresses (Size) Partition of array locked 0 0 None (Default) None (Default) 0 1 00h to 7Fh (128 bytes) GPM 1 0 00h to 7Fh and 90h to CFh (192 bytes) GPM, LUT1 1 1 00h to 7Fh and 90h to 10Fh (256 bytes) GPM, LUT1, LUT2 NV1234: CONTROL REGISTERS 1, 2, 3, AND 4 VOLATILITY MODE SELECTION BIT (NON-VOLATILE) When the NV1234 bit is set to “0” (default), bytes written to Control registers 1, 2, 3, and 4 are stored in volatile cells, and their content is lost when the X96012 is powered down. When the NV1234 bit is set to “1”, bytes written to Control registers 1, 2, 3, and 4 are stored in both volatile and nonvolatile cells, and their value doesn’t change when the X96012 is powered down and powered back up. See “Writing to Control Registers” on page 24. I1DS: CURRENT GENERATOR 1 DIRECTION SELECT BIT (NON-VOLATILE) The I1DS bit sets the polarity of Current Generator 1, DAC1. When this bit is set to “0” (default), the Current Generator 1 of the X96012 is configured as a Current Source. Current Generator 1 is configured as a Current Sink when the I1DS bit is set to “1”. See Figure 8. If the user attempts to perform a write operation to a protected region of memory, the operation is aborted without changing any data in the array. 11 FN8216.0 March 10, 2005 X96012 Figure 4. Control and Status Register Format Byte Address 80h Non-Volatile MSB LSB 7 6 5 4 I2DS I1DS NV1234 ADCfiltOff Control 1, 2, 3, 4 Volatility 0: Volatile 1: Nonvolatile ADC filtering 0: On 1: Off I1 and I2 Direction 0: Source 1: Sink 3 2 ADCIN VRM ADC Input 0: Internal 1: External Voltage Reference Mode 0: Internal 1: External 1 0 BL1 BL0 Register Name Control 0 Block Lock 00: None Locked 01: GPM Locked 10: GPM, LUT1, Locked 11: GPM, LUT1, LUT2 Locked Direct Access to LUT1 81h Volatile or Non-Volatile Reserved Reserved L1DA5 L1DA4 L1DA3 L1DA2 L1DA1 L1DA0 Control 1 L2DA5 L2DA4 L2DA3 L2DA2 L2DA1 L2DA0 Control 2 D1DA5 D1DA4 D1DA3 D1DA2 D1DA1 D1DA0 Control 3 Control 4 Direct Access to LUT2 82h Volatile or Non-Volatile Reserved Reserved Direct Access to DAC1 83h Volatile or Non-Volatile D1DA7 D1DA6 Direct Access to DAC2 84h Volatile or Non-Volatile D2DA7 D2DA6 D2DA5 D2DA4 D2DA3 D2DA2 D2DA1 D2DA0 85h Non-Volatile D2DAS L2DAS D1DAS L1DAS I2FSO1 I2FSO0 I1FSO1 I1FSO0 Direct Access to DAC2 0: Disabled 1: Enabled Direct Access to LUT2 0: Disabled 1: Enabled Direct Access to DAC1 0: Disabled 1: Enabled Direct Access to LUT1 0: Disabled 1: Enabled WEL Reserved Reserved Reserved 86h Volatile R2 Selection 00: External 01: Low Internal 10: Middle Internal 11: High Internal R1 Selection 00: External 01: Low Internal 10: Middle Internal 11: High Internal Reserved Reserved Reserved Reserved AD3 AD2 AD1 AD0 Control 5 Control 6 Write Enable Latch 0: Write Disabled 1: Write Enabled ADC Output 87h Volatile AD7 AD6 AD5 AD4 Status Registers in byte addresses 88h through 8Fh are reserved. 12 FN8216.0 March 10, 2005 X96012 I2DS: CURRENT GENERATOR 2 DIRECTION SELECT BIT (NON-VOLATILE) The I2DS bit sets the polarity of Current Generator 2, DAC2. When this bit is set to “0” (default), the Current Generator 2 of the X96012 is configured as a Current Source. Current Generator 2 is configured as a Current Sink when the I2DS bit is set to “1”. See Figure 8. D1DA7 - D1DA0: D/A 1 DIRECT ACCESS BITS When bit D1DAS (bit 5 in Control register 5) is set to “1”, the input to the D/A converter 1 is the content of bits D1DA7 - D1DA0, and it is not a row of LUT1. When bit D1DAS is set to “0” (default) these eight bits are ignored by the X96012. See Figure 9. Control Register 4 Control Register 1 This register is accessed by performing a Read or Write operation to address 81h of memory. This byte’s volatility is determined by bit NV1234 in Control register 0. This register is accessed by performing a Read or Write operation to address 84h of memory. This byte’s volatility is determined by bit NV1234 in Control register 0. D2DA7 - D2DA0: D/A 2 DIRECT ACCESS BITS L1DA5 - L1DA0: LUT1 DIRECT ACCESS BITS When bit L1DAS (bit 4 in Control register 5) is set to “1”, LUT1 is addressed by these six bits, and it is not addressed by the output of the on-chip A/D converter. When bit L1DAS is set to “0”, these six bits are ignored by the X96012. See Figure 10. A value between 00h (0010) and 3Fh (6310) may be written to these register bits, to select the corresponding row in LUT1. The written value is added to the base address of LUT1 (90h). Control Register 2 This register is accessed by performing a read or write operation to address 82h of memory. This byte’s volatility is determined by bit NV1234 in Control register 0. L2DA5 - L2DA0: LUT2 DIRECT ACCESS BITS When bit L2DAS (bit 6 in Control register 5) is set to “1”, LUT2 is addressed by these six bits, and it is not addressed by the output of the on-chip A/D converter. When bit L2DAS is set to “0”, these six bits are ignored by the X96012. See Figure 10. A value between 00h (0010) and 3Fh (6310) may be written to these register bits, to select the corresponding row in LUT2. The written value is added to the base address of LUT2 (D0h). Control Register 3 When bit D2DAS (bit 7 in Control register 5) is set to “1”, the input to the D/A converter 1 is the content of bits D2DA - D2DA0, and it is not a row of LUT2. When bit D2DAS is set to “0” (default) these eight bits are ignored by the X96012. (See Figure 9). Control Register 5 This register is accessed by performing a Read or Write operation to address 85h of memory. I1FSO1 - I1FSO0: CURRENT GENERATOR 1 FULL SCALE OUTPUT SET BITS (NON-VOLATILE) These two bits are used to set the full scale output current at the Current Generator 1 pin, I1. If both bits are set to “0” (default), an external resistor connected between pin R1 and Vss, determines the full scale output current available at pin I1. The other three options are indicated in the table below. The direction of this current is set by bit I1DS in Control register 0. See Figure 8. I1FSO1 0 0 1 1 I1FSO0 0 1 0 1 I1 Full Scale Output Current Set externally via pin R1 (Default) ±0.4mA* ±0.85 mA* ±1.3 mA* *No external resistor should be connected in these cases between R1 and VSS. This register is accessed by performing a Read or Write operation to address 83h of memory. This byte’s volatility is determined by bit NV1234 in Control register 0. 13 FN8216.0 March 10, 2005 X96012 I2FSO1 - I2FSO0: CURRENT GENERATOR 2 FULL SCALE OUTPUT CURRENT SET BITS (NON-VOLATILE) D2DAS: D/A 2 DIRECT ACCESS SELECT BIT (NONVOLATILE) These two bits are used to set the full scale output current at the Current Generator 2 pin, I2. If both bits are set to “0” (default), an external resistor connected between pin R2 and Vss, determines the full scale output current available at pin I2. The other three options are indicated in the table below. The direction of this current is set by bit I2DS in Control Register 0. When bit D2DAS is set to “0” (default), the input to the D/A converter 2 is a row of LUT2. When bit D2DAS is set to “1”, that input is the content of the Control register 4. I2FSO1 I2FSO2 I2 Full Scale Output Current 0 0 Set externally via pin R2 (Default) 0 1 ±0.4 mA* 1 0 ±0.85 mA* 1 1 ±1.3 mA* *No external resistor should be connected in these cases between R2 and VSS. L1DAS: LUT1 DIRECT ACCESS SELECT BIT (NONVOLATILE) When bit L1DAS is set to “0” (default), LUT1 is addressed by the output of the on-chip A/D converter. When bit L1DAS is set to “1”, LUT1 is addressed by bits L1DA5 - L1DA0. D1DAS: D/A 1 DIRECT ACCESS SELECT BIT (NONVOLATILE) When bit D1DAS is set to “0” (default), the input to the D/A converter 1 is a row of LUT1. When bit D1DAS is set to “1”, that input is the content of the Control register 3. L2DAS: LUT2 DIRECT ACCESS SELECT BIT (NONVOLATILE) When bit L2DAS is set to “0” (default), LUT2 is addressed by the output of the on-chip A/D converter. When bit L2DAS is set to “1”, LUT2 is addressed by bits L2DA5 - L2DA0. 14 Control Register 6 This register is accessed by performing a Read or Write operation to address 86h of memory. WEL: WRITE ENABLE LATCH (VOLATILE) The WEL bit controls the Write Enable status of the entire X96012 device. This bit must be set to “1” before any other Write operation (volatile or nonvolatile). Otherwise, any proceeding Write operation to memory is aborted and no ACK is issued after a Data Byte. The WEL bit is a volatile latch that powers up in the “0” state (disabled). The WEL bit is enabled by writing 100000002 to Control register 6. Once enabled, the WEL bit remains set to “1” until the X96012 is powered down, and then up again, or until it is reset to “0” by writing 000000002 to Control register 6. A Write operation that modifies the value of the WEL bit will not cause a change in other bits of Control register 6. Status Register - ADC Output This register is accessed by performing a Read operation to address 87h of memory. AD7 - AD0: A/D CONVERTER OUTPUT BITS (READ ONLY) These eight bits are the binary output of the on-chip A/D converter. The output is 000000002 for minimum input and 111111112 for full scale input. The six MSBs select a row of the LUTs. FN8216.0 March 10, 2005 X96012 these output bits are used to select a row in the lookup tables associated with the X96012’s Current Generators. When bit ADCfiltOff is “0” (default), bits AD[7:0] are updated each time the ADC performs four consecutive conversions with the same exact result at the 6 MSBs. When bit ADCfiltOff is “1”, these bits are updated after every ADC conversion. VOLTAGE REFERENCE The voltage reference to the A/D and D/A converters on the X96012, may be driven from the on-chip voltage reference, or from an external source via the VRef pin. Bit VRM in Control Register 0 selects between the two options (See Figure 5). The default value of VRM is “0”, which selects the internal reference. When the internal reference is selected, it’s output voltage is also an output at pin VRef with a nominal value of 1.21 V. If an external voltage reference is preferred, the VRM bit of the Control Register 0 must be set to “1”. A block diagram of the A/D converter is shown in Figure 6. The voltage reference input (see “VOLTAGE REFERENCE” for details), sets the maximum amplitude of the ramp generator output. The A/D converter input signal (see “A/D Converter Input Select” below for details) is compared to the ramp generator output. The control and encode logic produces a binary encoded output, with a minimum value of 00h (010), and a full scale output value of FFh (25510). Figure 5. Voltage Reference Structure The A/D converter input voltage range (VINADC) is from 0 V to V(VRef). VRM: bit 2 in Control register 0. A/D Converter Input Select On-chip Voltage Reference VRef Pin The input signal to the A/D converter on the X96012, may be the output of the on-chip temperature sensor, or an external source via the VSense pin. Bit ADCIN in Control register 0 selects between the two options (See Figure 7). It’s default value is “0”, which selects the internal temperature sensor. A/D Converter and D/A Converters reference If an external source is intended as the input to the A/D converter, the ADCIN bit of the Control register 0 must be set to “1”. A/D CONVERTER The X96012 contains a general purpose, on-chip, 8-bit Analog to Digital (A/D) converter whose output is available at the Status Register as bits AD[7:0]. By default Figure 6. A/D Converter Block Diagram Comparator A/D Converter Input Control and Encode Logic From VRef Ramp Generator Conversion Reset 8 A/D Converter Output (To LUTs and Status Register) Clock 15 FN8216.0 March 10, 2005 X96012 Figure 7. A/D Converter Input Select Structure A/D Converter Range ADCIN: bit 3 in Control register 0. VSense Pin To A/D Converter Input On-chip Temperature Sensor LOOK-UP TABLES The X96012 memory array contains two 64-byte lookup tables. One is associated to pin I1’s output current generator and the other to pin I2’s output current generator, through their corresponding D/A converters. The output of each look-up table is the byte contained in the selected row. By default these bytes are the inputs to the D/A converters driving pins I1 and I2. The byte address of the selected row is obtained by adding the look-up table base address (90h for LUT1, and D0h for LUT2) and the appropriate row selection bits. See Figure 9. VRef The table below summarizes the voltage range restrictions on the VSense and VRef pins in different configurations : By default the look-up table selection bits are the 6 MSBs of the A/D converter output. Alternatively, the A/D converter can be bypassed and the six row selection bits are the six LSBs of Control Registers 1 and 2, for the LUT1 and LUT2 respectively. The selection between these options is illustrated in Figure 10, and described in “I2DS: Current Generator 2 Direction Select Bit (Non-volatile)” on page 13, and “Control Register 2” on page 13. VSense and VRef ranges CURRENT GENERATOR BLOCK From Figure 6 we can see that the operating range of the A/D converter input depends on the voltage reference. And from Figure 7 we see that the internal temperature Sensor output also varies with the voltage reference (VRef). VRef A/D Converter Input Ranges Internal Internal Temp. Sensor Not Applicable Internal VSense Pin 0 ≤ V(VSense) ≤ V(VRef) External VSense Pin 0 ≤ V(VRef) ≤ 1.3 V 0 ≤ V(VSense) ≤ V(VRef) External Internal Temp. Sensor All voltages referred to Vss. 16 Not a Valid Case The Current Generator pins I1 and I2 are outputs of two independent current mode D/A converters. D/A Converter Operation The Block Diagram for each of the D/A converters is shown in Figure 8. The input byte of the D/A converter selects a voltage on the non-inverting input of an operational amplifier. The output of the amplifier drives the gate of a FET, whose source is connected to ground via resistor R1 or R2. This node is also fed back to the inverting input of the amplifier. The drain of the FET is connected to the output current pin (I1 or I2) via a “polarity select” circuit block. FN8216.0 March 10, 2005 X96012 Figure 8. D/A Converter Block Diagram Vcc Polarity Select Circuit I1DS or I2DS: bits 6 or 7 in Control register 0. VRef DAC1 or DAC2 Input byte Voltage Divider I1 or I2 Pin + - R1 or R2 Pin 11 00 R1_Middle_Current or R2_Middle_Current R1_High_Current or R2_High_Current 10 Vss 01 R1_Low_Current or R2_Low_Current I1FSO[1:0] or I2FSO[1:0] bits 1 and 0, or 3 and 2 in Control register 5 Vss R1_External or R2_External Optional external resistor Vss Vss Figure 9. Look-up Table (LUT) Operation D2DA[7:0] : Control register 4 6 8 D0h A D D E R 8 … LUT2 Row Selection bits LUT2 10Fh 8 D1 D0 Out 8 DAC 2 Input Byte Select D0h D2DAS: Bit 7 of Control register 5 D1DA[7:0] : Control register 3 6 8 90h A D D E R 8 … LUT1 Row Selection bits LUT1 CFh 8 8 D1 D0 Out DAC 1 Input Byte Select 90h D1DAS: Bit 5 of Control register 5 17 FN8216.0 March 10, 2005 X96012 By examining the block diagram in Figure 8, we see that the maximum current through pin I1 is set by fixing values for V(VRef) and R1. The output current can then be varied by changing the data byte at the D/A converter input. Bits I1DS and I2DS in Control Register 0 select the direction of the currents through pins I1 and I2 independently (See “I1DS: Current Generator 1 Direction Select Bit (Non-volatile)” on page 11 and “Control and Status Register Format” on page 12). In general, the magnitude of the current at the D/A converter output pins (I1, I2) may be calculated by: D/A Converter Output Current Response Ix = (V(VRef) / (384 • Rx)) • N where x = 1,2 and N is the decimal representation of the input byte to the corresponding D/A converter. The value for the resistor Rx (x = 1,2) determines the full scale output current that the D/A converter may sink or source. The full scale output current has a maximum value of ±3.2 mA, which is obtained using a resistance of 255Ω for Rx. This resistance may be connected externally to pin Rx of the X96012, or may be selected from one of three internal values. Bits I1FSO1 and I1FSO0 select the full scale output current setting for I1 as described in “I1FSO1 - I1FSO0: Current Generator 1 Full Scale Output Set Bits (Non-volatile)” on page 13. Bits I2FSO1 and I2FSO0 select the maximum current setting for I2. When an internal resistor is selected for R1 or R2, then no resistor should be connected externally at the corresponding pin. When the D/A converter input data byte changes by an arbitrary number of bits, the output current changes from an intial current level (Ix) to some final level (Ix + ∆Ix). The transition is monotonic and glitchless. D/A Converter Control The data byte inputs of the D/A converters can be controlled in three ways: – 1) With the A/D converter and through the look-up tables (default), – 2) Bypassing the A/D converter and directly accessing the look-up tables, – 3) Bypassing both the A/D converter and look-up tables, and directly setting the D/A converter input byte. Figure 10. Look-Up Table Addressing L2DA[5:0]: Control Register 2 Voltage Reference D1 Out D0 LUT2 Row Selection bits Select 6 ADC Voltage Input L2DAS: bit 6 in Control register 5 8 AD[7:0] Status Register L1DA[5:0]: 6 Control Register 1 D1 Out D0 Select LUT1 Row Selection bits L1DAS: bit 4 in Control register 5 18 FN8216.0 March 10, 2005 X96012 The options are summarized in the following tables: D/A Converter 1 Access Summary L1DAS D1DAS Control Source 0 0 A/D converter through LUT1 (Default) 1 0 Bits L1DA5 - L1DA0 through LUT1 X 1 Bits D1DA7 - D1DA0 “X” = Don’t Care Condition (May be either “1” or “0”) D/A Converter 2 Access Summary L2DAS D2DAS Control Source 0 0 A/D converter through LUT2 (Default) 1 0 Bits L2DA5–L2DA0 through LUT2 X 1 Bits D2DA7–D2DA0 “X” = Don’t Care Condition (May be either “1” or “0”) The A/D converter is shared between the two current generators but the look-up tables, D/A converters, control bits, and selection bits can be set completely independently. Bits D1DAS and D2DAS are used to bypass the A/D converter and look-up tables, allowing direct access to the inputs of the D/A converters with the bytes in control registers 3 and 4 respectively. See Figure 9, and the descriptions of the control bits. Bits I1DS and I2DS in Control Register 0 select the direction of the currents through pins I1 and I2 independently See Figure 8, and the descriptions of the control bits. 19 POWER-ON RESET When power is applied to the Vcc pin of the X96012, the device undergoes a strict sequence of events before the current outputs of the D/A converters are enabled. When the voltage at Vcc becomes larger than the power-on reset threshold voltage (VPOR), the device recalls all control bits from non-volatile memory into volatile registers. Next, the analog circuits are powered up. When the voltage at Vcc becomes larger than a second voltage threshold (VADCOK), the ADC is enabled. In the default case, after the ADC performs four consecutive conversions with the same exact result, the ADC output is used to select a byte from each look-up table. Those bytes become the input of the DACs. During all the previous sequence the input of both DACs are 00h. If bit ADCfiltOff is “1”, only one ADC conversion is necessary. Bits D1DAS, D2DAS, L1DAS, and L2DAS, also modify the way the two DACs are accessed the first time after power-up, as described in “Control Register 5” on page 13. The X96012 is a hot pluggable device. Voltage distrubances on the Vcc pin are handled by the power-on reset circuit, allowing proper operation during hot plugin applications. SERIAL INTERFACE Serial Interface Conventions The device supports a bidirectional bus oriented protocol. The protocol defines any device that sends data onto the bus as a transmitter, and the receiving device as the receiver. The device controlling the transfer is called the master and the device being controlled is called the slave. The master always initiates data transfers, and provides the clock for both transmit and receive operations. The X96012 operates as a slave in all applications. FN8216.0 March 10, 2005 X96012 Figure 11. D/A Converter Power-on Reset Response Voltage Vcc VADCOK 0V Time Current Ix ADC TIME Ix x 10% Serial Clock and Data Data states on the SDA line can change only while SCL is LOW. SDA state changes while SCL is HIGH are reserved for indicating START and STOP conditions. See Figure 13. On power-up of the X96012, the SDA pin is in the input mode. Serial Start Condition All commands are preceded by the START condition, which is a HIGH to LOW transition of SDA while SCL is HIGH. The device continuously monitors the SDA and SCL lines for the START condition and does not respond to any command until this condition has been met. See Figure 12. Serial Stop Condition All communications must be terminated by a STOP condition, which is a LOW to HIGH transition of SDA while SCL is HIGH. The STOP condition is also used to place the device into the Standby power mode after a read sequence. A STOP condition can only be issued after the transmitting device has released the bus. See Figure 12. Time The device responds with an ACK after recognition of a START condition followed by a valid Slave Address byte. A valid Slave Address byte must contain the Device Type Identifier 1010, and the Device Address bits matching the logic state of pins A2, A1, and A0. See Figure 16. If a write operation is selected, the device responds with an ACK after the receipt of each subsequent eight-bit word. In the read mode, the device transmits eight bits of data, releases the SDA line, and then monitors the line for an ACK. The device continues transmitting data if an ACK is detected. The device terminates further data transmissions if an ACK is not detected. The master must then issue a STOP condition to place the device into a known state. The X96012 acknowledges all incoming data and address bytes except: 1) The “Slave Address Byte” when the “Device Identifier” or “Device Address” are wrong; 2) All “Data Bytes” when the “WEL” bit is “0”, with the exception of a “Data Byte” addresses to location 86h; 3) “Data Bytes” following a “Data Byte” addressed to locations 80h, 85h, or 86h. Serial Acknowledge An ACK (Acknowledge), is a software convention used to indicate a successful data transfer. The transmitting device, either master or slave, releases the bus after transmitting eight bits. During the ninth clock cycle, the receiver pulls the SDA line LOW to acknowledge the reception of the eight bits of data. See Figure 14. 20 FN8216.0 March 10, 2005 X96012 Figure 12>. Valid Start and Stop Conditions SCL SDA STOP START Figure 13>. Valid Data Changes on the SDA Bus SCL SDA Data Stable Data Change Data Stable Figure 14. Acknowledge Response From Receiver SCL from Master 1 8 9 SDA Output from Transmitter SDA Output from Receiver START 21 ACK FN8216.0 March 10, 2005 X96012 X96012 Memory Map Addressing Protocol Overview The X96012 contains a 2176 bit array of mixed volatile and nonvolatile memory. This array is split up into four distinct parts, namely: (Refer to figure 15.) All Serial Interface operations must begin with a START, followed by a Slave Address Byte. The Slave address selects the X96012, and specifies if a Read or Write operation is to be performed. – General Purpose Memory (GPM) – Look-up Table 1 (LUT1) – Look-up Table 2 (LUT2) – Control and Status Registers The GPM is all nonvolatile EEPROM, located at memory addresses 00h to 7Fh. Even though the 2176 bit memory consists of four differing functions, it is physically realized as one contiguous array, organized as 17 pages of 16 bytes each. Figure 15. X96012 Memory Map Address Size 10Fh Look-up Table 2 FFh It should be noted that the Write Enable Latch (WEL) bit must first be set in order to perform a Write operation to any other bit. (See “WEL: Write Enable Latch (Volatile)” on page 14.) Also, all communication to the X96012 over the 2-wire serial bus is conducted by sending the MSB of each byte of data first. 64 Bytes (LUT2) The X96012 2-wire protocol provides one address byte, therefore, only 256 bytes can be addressed directly. The next few sections explain how to access the different areas for reading and writing. D0h CFh Look-up Table 1 64 Bytes Figure 16. Slave Address (SA) Format (LUT1) 90h SA7 8Fh Control & Status SA4 SA3 SA2 SA1 0 AS2 AS1 AS0 SA0 16 Bytes 1 Registers 80h 7Fh SA6 SA5 General Purpose 128 Bytes Memory (GPM) 0 1 Device Type Identifier Device Address R/W Read or Write 00h 7 0 The Control and Status registers of the X96012 are used in the test and setup of the device in a system. These registers are realized as a combination of both volatile and nonvolatile memory. These registers reside in the memory locations 80h through 8Fh. The reserved bits within registers 80h through 86h, must be written as “0” if writing to them, and should be ignored when reading. The reserved registers, from 88h through 8Fh, must not be written, and their content should be ignored. Slave Address Bit(s) Description SA7 - SA4 Device Type Identifier SA3 - SA1 Device Address SA0 Read or Write Operation Select Both look-up tables LUT1 and LUT2 are realized as nonvolatile EEPROM, and extend from memory locations 90h - CFh and D0h - 10Fh respectively. These look-up tables are dedicated to storing data solely for the purpose of setting the outputs of Current Generators I1 and I2 respectively. All bits in both look-up tables are preprogrammed to “0” at the factory. 22 FN8216.0 March 10, 2005 X96012 Slave Address Byte Nonvolatile Write Acknowledge Polling Following a START condition, the master must output a Slave Address Byte (Refer to figure 16.). This byte includes three parts: After a nonvolatile write command sequence is correctly issued (including the final STOP condition), the X96012 initiates an internal high voltage write cycle. This cycle typically requires 5 ms. During this time, any Read or Write command is ignored by the X96012. Write Acknowledge Polling is used to determine whether a high voltage write cycle is completed. – The four MSBs (SA7 - SA4) are the Device Type Identifier, which must always be set to 1010 in order to select the X96012. – The next three bits (SA3 - SA1) are the Device Address bits (AS2 - AS0). To access any part of the X96012’s memory, the value of bits AS2, AS1, and AS0 must correspond to the logic levels at pins A2, A1, and A0 respectively. – The LSB (SA0) is the R/W bit. This bit defines the operation to be performed on the device being addressed. When the R/W bit is “1”, then a Read operation is selected. A “0” selects a Write operation (Refer to figure 16.) Figure 17. Acknowledge Polling Sequence Issue START ACK returned? Issue STOP NO YES High Voltage complete. Continue command sequence. YES Continue normal Read or Write command sequence PROCEED 23 Byte Write Operation In order to perform a Byte Write operation to the memory array, the Write Enable Latch (WEL) bit of the Control 6 Register must first be set to “1”. (See “WEL: Write Enable Latch (Volatile)” on page 14.) Byte load completed by issuing STOP. Enter ACK Polling Issue Slave Address Byte (Read or Write) During acknowledge polling, the master first issues a START condition followed by a Slave Address Byte. The Slave Address Byte contains the X96012’s Device Type Identifier and Device Address. The LSB of the Slave Address (R/W) can be set to either 1 or 0 in this case. If the device is busy within the high voltage cycle, then no ACK is returned. If the high voltage cycle is completed, an ACK is returned and the master can then proceed with a new Read or Write operation. (Refer to figure 17.). NO Issue STOP For any Byte Write operation, the X96012 requires the Slave Address Byte, an Address Byte, and a Data Byte (See Figure 18). After each of them, the X96012 responds with an ACK. The master then terminates the transfer by generating a STOP condition. At this time, if all data bits are volatile, the X96012 is ready for the next read or write operation. If some bits are nonvolatile, the X96012 begins the internal write cycle to the nonvolatile memory. During the internal nonvolatile write cycle, the X96012 does not respond to any requests from the master. The SDA output is at high impedance. A Byte Write operation can access bytes at locations 00h through FEh directly, when setting the Address Byte to 00h through FEh respectively. Setting the Address Byte to FFh accesses the byte at location 100h. The other sixteen bytes, at locations FFh and 101h through 10Fh can only be accessed using Page Write operations. The byte at location FFh can only be written using a “Page Write” operation. Writing to Control bytes which are located at byte addresses 80h through 8Fh is a special case described in the section “Writing to Control Registers” . FN8216.0 March 10, 2005 X96012 Figure 18. Byte Write Sequence Write S t a r t Signals from the Master Signal at SDA 10 10 S t o p Data Byte Address Byte Slave Address 0 Signals from the Slave A C K A C K Page Write Operation The 2176-bit memory array is physically realized as one contiguous array, organized as 17 pages of 16 bytes each. A “Page Write” operation can be performed to any of the GPM or LUT pages. In order to perform a Page Write operation to the memory array, the Write Enable Latch (WEL) bit in Control register 6 must first be set (See “WEL: Write Enable Latch (Volatile)” on page 14.) A Page Write operation is initiated in the same manner as the byte write operation; but instead of terminating the write cycle after the first data byte is transferred, the master can transmit up to 16 bytes (See Figure 19). After the receipt of each byte, the X96012 responds with an ACK, and the internal byte address counter is incremented by one. The page address remains constant. When the counter reaches the end of the page, it “rolls over” and goes back to the first byte of the same page. For example, if the master writes 12 bytes to a 16-byte page starting at location 11 (decimal), the first 5 bytes are written to locations 11 through 15, while the last 7 bytes are written to locations 0 through 6 within that page. Afterwards, the address counter would point to location 7. If the master supplies more than 16 bytes of data, then new data overwrites the previous data, one byte at a time (See Figure 20). A C K The master terminates the loading of Data Bytes by issuing a STOP condition, which initiates the nonvolatile write cycle. As with the Byte Write operation, all inputs are disabled until completion of the internal write cycle. A Page Write operation cannot be performed on the page at locations 80h through 8Fh. Next section describes the special cases within that page. A Page Write operation starting with byte address FFh, accesses the page between locations 100h and 10Fh. The first data byte of such operation is written to location 100h. Writing to Control Registers The byte at location 80h, 85h, and 86h are written using Byte Write operations. They cannot be written using a Page Write operation. Control bytes 1 through 4, at locations 81h through 84h respectively, are written during a single operation (See Figure 21). The sequence must be: a START, followed by a Slave Address byte, with the R/W bit equal to “0”, followed by 81h as the Address Byte, and then followed by exactly four Data Bytes, and a STOP condition. The first data byte is written to location 81h, the second to 82h, the third to 83h, and the last one to 84h. Figure 19. Page Write Operation Write S t a r t Signals from the Master 2 < n < 16 Address Byte Slave Address Data Byte (1) S t o p Data Byte (n) Signal at SDA 10 1 0 Signals from the Slave 0 A C K 24 A C K A C K A C K FN8216.0 March 10, 2005 X96012 Figure 20. Example: Writing 12 bytes to a 16-byte page starting at location 11. 5 bytes 5 bytes 7 bytes Address=6 Address=0 Address=11 Address=7 Address Pointer Ends Up Here The four registers Control 1 through 4, have a nonvolatile and a volatile cell for each bit. At power-up, the content of the nonvolatile cells is automatically recalled and written to the volatile cells. The content of the volatile cells controls the X96012’s functionality. If bit NV1234 in the Control 0 register is set to “1”, a Write operation to these registers writes to both the volatile and nonvolatile cells. If bit NV1234 in the Control 0 register is set to “0”, a Write operation to these registers only writes to the volatile cells. In both cases the newly written values effectively control the X96012, but in the second case, those values are lost when the part is powered down. If bit NV1234 is set to “0”, a Byte Write operation to Control registers 0 or 5 causes the value in the nonvolatile cells of Control registers 1 through 4 to be recalled into their corresponding volatile cells, as during power-up. This doesn’t happen when the WP pin is LOW, because Write Protection is enabled. It is generally recommended to configure Control registers 0 and 5 before writing to Control registers 1 through 4. Address=15 When reading any of the control registers 1, 2, 3, or 4, the Data Bytes are always the content of the corresponding nonvolatile cells, even if bit NV1234 is "0" (See “Control and Status Register Format”). Read Operation A Read operation consist of a three byte instruction followed by one or more Data Bytes (See Figure 22). The master initiates the operation issuing the following sequence: a START, the Slave Address byte with the R/W bit set to “0”, an Address Byte, a second START, and a second Slave Address byte with the R/W bit set to “1”. After each of the three bytes, the X96012 responds with an ACK. Then the X96012 transmits Data Bytes as long as the master responds with an ACK during the SCL cycle following the eigth bit of each byte. The master terminates the read operation (issuing a STOP condition) following the last bit of the last Data Byte (See Figure 22). Figure 21. Writing to Control Registers 1, 2, 3, and 4 Four Data Bytes Signals from the Master S t a r t Write Slave Address Address Byte = 81h Data Byte for Control 1 S t o p Data Byte for Control 4 Signal at SDA 10 10 Signals from the Slave 10 0 0 0 0 01 0 A C K 25 A C K A C K A C K FN8216.0 March 10, 2005 X96012 Figure 22. Read Sequence Signals from the Master S t a r t Signal at SDA Slave Address with R/W=0 10 1 0 S t a r t Address Byte 10 10 0 A C K Signals from the Slave A C K The Data Bytes are from the memory location indicated by an internal pointer. This pointer initial value is determined by the Address Byte in the Read operation instruction, and increments by one during transmission of each Data Byte. After reaching the memory location 10Fh the pointer “rolls over” to 00h, and the device continues to output data for each ACK received. A Read operation internal pointer can start at any memory location from 00h through FEh, when the Address Byte is 00h through FEh respectively. But it starts at location 100h if the Address Byte is FFh. When reading any of the control registers 1, 2, 3, or 4, the Data Bytes are always the content of the corresponding nonvolatile cells, even if bit NV1234 is "0" (See “Control and Status Register Format”). 26 Slave Address with R/W=1 A C K S t o p A C K 1 A C K First Read Data Byte Last Read Data Byte Data Protection There are four levels of data protection designed into the X96012: 1- Any Write to the device first requires setting of the WEL bit in Control 6 register; 2- The Block Lock can prevent Writes to certain regions of memory; 3- The Write Protection pin disables any writing to the X96012; 4- The proper clock count, data bit sequence, and STOP condition is required in order to start a nonvolatile write cycle, otherwise the X96012 ignores the Write operation. WP: Write Protection Pin When the Write Protection (WP) pin is active (LOW), any Write operations to the X96012 is disabled, except the writing of the WEL bit. FN8216.0 March 10, 2005 X96012 PACKAGING INFORMATION 14-Lead Plastic, TSSOP, Package Code V14 .025 (.65) BSC .169 (4.3) .252 (6.4) BSC .177 (4.5) .193 (4.9) .200 (5.1) .041 (1.05) .0075 (.19) .0118 (.30) .002 (.05) .006 (.15) .010 (.25) Gage Plane 0° - 8° Seating Plane .019 (.50) .029 (.75) Detail A (20X) .031 (.80) .041 (1.05) See Detail “A” NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS) All Intersil U.S. products are manufactured, assembled and tested utilizing ISO9000 quality systems. Intersil Corporation’s quality certifications can be viewed at www.intersil.com/design/quality Intersil products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design, software and/or specifications at any time without notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate and reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Intersil or its subsidiaries. For information regarding Intersil Corporation and its products, see www.intersil.com 27 FN8216.0 March 10, 2005