pdf

www.osram.com
Product Information
LED PARATHOM® PAR16 50 36°
Product Overview
Product
Wattage
CCT in K
lm
Beam
Angle
Base
LED PARATHOM® PAR16 50 36°
36
7,5
2700
385
36°
GU10
LED PARATHOM® PAR16 50 36°
36
7,5
3000
390
36°
GU10
LED PARATHOM® PAR16 50 36°
36
7,5
4000
400
36°
GU10
Benefits
Key Features
• 1 to 1 replacement to HAL PAR16
• Same light output as a 50W HAL, but -85% energy
• Long lifetime
• Dimmable
• LED PAR16 lamp as replacement for Halogen PAR16 50W
• voltage: 220 – 240V
• GU10 base
• beam angle 36°
36
• available in light color warm white 2700°K
2700 & 3000°K, as well as cool
white 4000°K
4000
• reduces energy consumption ~ 85%
• dimmable, working on most common dimmers down to 10%
• light-to-the-back
light
effect
• shock-proof
shock
and vibration-proof
• 25,000 hours lifetime
• UV and NIR radiation free
• mercury free
• 4 years Osram Guarantee1
1
See www.osram.com/guarantee
LED PARATHOM® PAR16 50 36°
BU LP PPM Led Lamps
For internal use only
1
www.osram.com
Product Information
LED PARATHOM® PAR16 50 36°
Ordering Guide
Product
Wattage
CCT
lm
Candela
Diameter Lenght
Weight
Beam
Angle
EAN10
EAN40
(ship.unit)
Ship.
unit
LED PARATHOM® PAR16
50 36°
7,5
2700
385
950
50 mm
58 mm
75 g
36°
4008321882097
4008321882103
10
LED PARATHOM® PAR16
50 36°
7,5
3000
390
950
50 mm
58 mm
75 g
36°
4008321882127
4008321882134
10
LED PARATHOM® PAR16
50 36°
7,5
4000
400
1000
50 mm
58 mm
75 g
36°
4008321882158
4008321882165
10
Common Characteristics3
Type
Average
lifetime4
Switching
cycles
Casing material
Starting time
Warm up time for
60% light
Power factor
LED PARATHOM® PAR16 50 36°
25,000 hrs
100,000
Metal
Metal/plastic
<0.5s
none
0.75
Nominal
current
Max. inrush
current
Tc temperature
max.5
CRI
Mercury max.
80
80°C
80
0.0 mg
(30s on, 30s off)
LED PARATHOM® PAR16 50 36°
42mA
Disposal information
• Lamps with WEEE sign can be returned at specific collection points.
• LED lamps have to be disposed as special waste.
3 Typical values. All the technical parameters apply to the entire lamp. In view of the complex manufacturing process for light emitting diodes, the typical values given
above for the technical LED parameters are merely statistical values that do not necessarily correspond to the actual technical
technic parameters of an individual product;
individual products may vary from the typical values.
4 The average lifetime of LED lamps is defined as the number of hours when the light output of 50% of a large group of identical
identica lamps goes below 70% of its initial
luminous flux (L70B50, IEC60969).The lifetime is estimated at room temperature (25°°C), free air burning, base up burning position and at rated voltage. To achieve a
full lifetime a good heat exchange for the electronic components is required.
5 The Tc is defined as the highest permissible temperature which may occur on the outer surface of the LED lamp (in the indicated
indicat position) under normal operating
conditions and at the rated voltage/current/power or the maximum of the rated voltage/current/power range (DIN EN 62031: 2009-01)
2009
LED PARATHOM® PAR16 50 36°
BU LP PPM Led Lamps
For internal use only
2
www.osram.com
Product Information
LED PARATHOM® PAR16 50 36°
Light distribution
2700/3000K, 36° beam angle
4000K, 36° beam angle
Application information
Application Notes
• hotels
• restaurant
• commercial areas
• residentials
• art galleries and museum
• office space
1.
2.
3.
4.
suitable for indoor application.
for outdoor applications and operation in damp
locations special approved fixture are required.
Input voltage: AC: 220-240V
Operating and storage temperature range between 20°C and 40°C
Lamp conformity
•
•
•
•
•
•
•
•
•
2004/108/EC Electromagnetic compatibility (EMC)
244/2009 Ecodesign requirements for non-directional
directional household lamps
IEC/ PAS 62612 Self ballasted LED-lamps
lamps for general lighting services – Performance requirements
2009/125/EC Ecodesign requirements for energy related products
2011/65/EC Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS)
(
1907/2006 Registration, Evaluation, Authorization and Restriction of Chemicals (REACH Regulation)
2002/96/EC Waste Electrical and Electronic Equipment Directive (WEEE)
EN 62471 Photobiological safety of lamps and lamp systems
IEC/TR 62471-2 Photobiological safety of lamps and lamp systems - Part 2: Guidance on manufacturing requirements
relating to non-laser optical radiation safety
• EN 55015 Limits and methods of measurement of radio disturbance
• EN 61000-3-2 Electromagnetic compatibility – Limits for harmonic current emission
• EN 61000-3-3 Electromagnetic compatibility – Limitation of voltage changes, voltage fluctuations, flicker in public low
voltage supply systems
• EN61547 Electromagnetic compatibility immunity requirements
• 1194/2012 Eco design requirement for directional lamps, light emitting diode lamps and related equipment (DIM II)
• IEC 62560 self-ballasted LED-lamps
lamps for general lighting services by voltage >50V – Safety specifications
• 874/2012/EU Energy labeling of electrical lamps and luminaires
LED PARATHOM® PAR16 50 36°
BU LP PPM Led Lamps
For internal use only
3
www.osram.com
Product Information
LED PARATHOM® PAR16 35 36°
Compatibility performance with dimmer 6
Legend
L / leading edge
T / trailing edge
Dim range
1 lamp
Dim range
2 lamps
Dim range
4 lamps
Dim range
6 lamps
Dim range
10 lamps
Supplier
Model
Type
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
Siemens
5TC8 284
T
4%
90%
2%
82%
2%
75%
2%
71%
2%
71%
Berker
Merfen
286110
5771
T
T
10%
9%
99%
93%
10%
9%
100%
100%
10%
8%
100%
87%
9%
8%
100%
87%
8%
7%
100%
81%
Gira
0307 00/I01
T
5%
99%
5%
100%
5%
100%
5%
100%
4%
100%
Busch
Peha
REV
6513U-102
433 HAB
13623
T
T
L
8%
6%
9%
99%
85%
98%
6%
7%
11%
100%
86%
100%
6%
6%
14%
100%
82%
100%
5%
7%
16%
100%
87%
100%
5%
6%
22%
99%
81%
99%
ELSO
174120
L
12%
100%
15%
100%
17%
100%
19%
100%
28%
100%
BUSCH
GIRA
2250U
030000
L
6%
100%
7%
100%
8%
100%
9%
100%
10%
99%
L
0%
99%
0%
100%
0%
100%
0%
100%
0%
100%
DUWI
14188
L
17%
100%
22%
100%
31%
100%
40%
100%
46%
100%
BUSCH
JUNG
2247U
225 NV DE
L
4%
100%
4%
100%
4%
100%
5%
100%
6%
100%
Duwi
14386
L
L
5%
14%
100%
100%
6%
19%
100%
100%
7%
28%
100%
100%
8%
38%
100%
100%
9%
51%
100%
100%
KOPP
80,33
L
14%
100%
17%
100%
22%
100%
30%
100%
42%
100%
L
16%
100%
21%
100%
29%
100%
42%
100%
46%
100%
L
11%
100%
12%
100%
15%
100%
17%
100%
28%
100%
L
0%
100%
0%
100%
0%
100%
0%
100%
0%
100%
T
9%
100%
8%
100%
7%
96%
7%
96%
7%
92%
T
10%
100%
10%
100%
0%
0%
0%
0%
9%
100%
6%
5%
6%
14%
7%
5%
6%
100%
100%
100%
100%
100%
100%
100%
5%
5%
6%
14%
8%
6%
7%
100%
100%
100%
100%
100%
100%
100%
6%
4%
6%
15%
9%
6%
6%
100%
100%
100%
100%
100%
100%
100%
6%
4%
5%
15%
8%
5%
7%
100%
100%
100%
100%
100%
100%
100%
5%
4%
5%
15%
8%
5%
6%
96%
100%
100%
100%
100%
100%
100%
9%
76%
7%
77%
6%
70%
6%
66%
5%
63%
Siemens
5TC8 256
Lichtregler
JUNG
T38S
244020300
Duwi
14485
JUNG
BUSCH
KOPP
254 UD IE 1
6591 U-101
80,78
BUSCH
Schneider
Lichtregler
GIRA
Merten
6519U
ATD315
T46S
030700/I02
SBD315RC
T
T
T
T
T
T
T
VADSBO
TD 350
T
Comment
Audible noise with
10 lamps
Audible noise with
4 lamps
Audible noise with
4 lamps
Audible noise with
4 lamps
No audible noise
only with 4 lamps
Audible noise with
10 lamps
Audible noise with
10 lamps
Audible noise with
10 lamps
6 Typical valuesThe
The test results reflect the measurement of the individual devices that were used in tests. OSRAM does not take over any responsibility,
resp
warranty or liability
that this results can also be achieved by using the devices under other conditions or when using successor models of the tested
test devices or different models of the same
manufacturer.
lamp types. OSRAM does not take over any responsibility, warranty
warrant or liability that this results can also be
The test results were achieved by using the above mentioned LED-lamp
achieved by using the devices under other conditions or when using other LED-lamp
lamp types.
LED PARATHOM® PAR16 50 36°
BU LP PPM Led Lamps
For internal use only
4