DWDM 40km SFP+ Transceivers TPD1XGJERxx Pb Product Description The TPD1XGJERxx is an enhanced small form factor pluggable (SFP+) fiber optic transceiver with digital diagnostics monitoring functionality (DDM). Supporting Ethernet and Fiber Channel standards with dense wavelength division multiplexing (DWDM) wavelength makes it ideally suited for high capacity data-com and storage area network applications. DDM functionality (alarm and warning features) is integrated into the design via an I2C serial interface per the Multi-Source Agreement (MSA) SFF-8472, Rev. 10.4. Each transceiver utilizes an electro absorption modulator integrated laser (EML) with an operating wavelength with 100GHz (0.8nm) spacing per the ITU-grid. The transceiver supports data rates ranging from 11.3Gbps down to 8Gbps. It provides an excellent solution for data transmission at DWDM wavelength over up to 40km single mode fiber. The low power consumption and excellent EMI performance enable system design with high port density. The product is RoHS compliant and is designed and tested in accordance with industry safety standards. The transceiver is Class I Laser product per U.S. FDA/CDRH and international IEC-60825 standards. The TPD1XGJERxx transceiver connects to standard 20-pad SFP+ connectors for hot plug capability. This allows the system designer to make configuration changes or maintenance by simply plugging in different transceivers without removing the power supply from the host system. The transmitter and receiver DATA interfaces are internally AC-coupled. LV-TTL Transmitter Disable control input and Loss of Signal (LOS) output interfaces are also provided. The transceiver has bail-type latch, which offers an easy and convenient way to release the modules. The transceiver operates from a single +3.3V power supply over an operating case temperature range of -5°C to +70°C (Commercial), or -5°C to +85°C (Extended) or -40°C to +85°C (Industrial). Features Temperature-stablized DWDM EML transmitter Multi-rate for Ethernet & Fiber Channel Transmission distance up to 40km (SM Fiber) Low power consumption Wide case operating temperature range Compliant to SFP+ Electrical MSA SFF-8431 Compliant to SFP+ Mechanical MSA SFF-8432 Compliant to 10GBASE-E specifications Digital Diagnostics Monitoring (DDM) through Serial Interface comply with SFF-8472, Rev. 10.4 RoHS 6/6 Compliant Laser Class 1 IEC/CDRH compliant Absolute Maximum Ratings Parameter Storage Temperature Range Symbol Minimum Maximum Units TST - 40 + 85 °C -5 + 70 -5 + 85 - 40 + 85 RH 0 85 % VCC - 0.5 + 3.6 V “Commercial” Operating Case Temperature 1 “Extended” TOP “Industrial” Operating Relative Humidity Supply Voltage Range 2 °C Measured on top side of SFP+ module at the front center vent hole of the cage. 2 Non condensing 1 S0217. Rev.02 (web) 2014-02-24 TPD1XGJERxx Transmitter Performance Characteristics Parameter (Over Operating Case Temperature. VCC = 3.13 to 3.47V) Symbol Minimum Typical Maximum Units Data Rate B 8.0 - 11.3 Gb/s Center Wavelength 1 λC Spectral Width (-20dB) Average Optical Output Power 2 Optical Modulation Amplitude See Ordering Information Table nm Δλ 20 - - 1.0 nm PAvg 0 - +4 dBm POMA 0 - - dBm ER 4.5 - - dB Extinction Ratio RIN21OMA - - - 128 dB/Hz Side Mode Suppression Ratio SMSR 30 - - dB Optical Return Loss Tolerance - - - - 21 dB TDP - - 3 dB Relative Intensity Noise in OMA Transmitter and Dispersion Penalty @ 10.3125Gb/s Compliant with IEEE 802.3ae Optical Output Eye 1 2 BOL : ±0.05nm from ITU grid; EOL: ±0.1nm from ITU grid. Average power figures are informative only, per IEEE 802.3ae. Receiver Performance Characteristics Parameter Data Rate Wavelength of Operation Receiver Sensitivity OMA @ 10.3125Gb/s 1 Stressed Receiver Sensitivity in OMA (@ 10.3125Gb/s) 2 Maximum Input Optical Power (10 -12 BER) (Over Operating Case Temperature. VCC = 3.13 to 3.47V) Symbol Minimum Typical Maximum Units B 8.0 - 11.3 Gb/s λ 1530 - 1565 nm Pmin - - - 14.1 dBm - - - - 11.3 dBm Pmax -1 - - dBm Receiver Reflectance - - - - 26 dB LOS Hysteresis - 0.5 - - dB Increasing Light Input Plos+ - - - 16 Decreasing Light Input Plos- - 30 - - LOS Thresholds 1 2 dBm Specified with BER <1x10-12 and PRBS 2 31-1. Comply with IEEE 802.3ae Note: The specified characteristics are met within the recommended range of operation. Unless otherwise noted typical data are quoted at nominal voltage and +25°C ambient temperature. Laser Safety: All transceivers are Class 1 Laser products per FDA/CDRH and IEC-60825 standards. They must be operated under specified operating conditions. Oplink Communications, Inc. This product complies with 21 CFR 1040.10 and 1040.11 Meets Class 1 Laser Safety Requirements Oplink Communications, Inc 2 S0217. Rev.02 (web) 2014-02-24 TPD1XGJERxx Transmitter Electrical Characteristics Parameter Differential Input Impedance Differential Input Voltage Swing Input HIGH Voltage (TX Disable) 1 (Over Operating Case Temperature. VCC = 3.13 to 3.47V) Symbol Minimum Typical Maximum Units Zd - 100 - Ω VPP-DIFF 180 - 700 mV VIH 2.0 - VCC V 1 VIL 0 - 0.8 V Output HIGH Voltage (TX Fault) 2 VOH 2.0 - VCC + 0.3 V Output LOW Voltage (TX Fault) VOL 0 - 0.8 V Input LOW Voltage (TX Disable) 1 2 2 There is an internal 4.7kΩ to 10kΩ pull-up resistor to VccT. Open collector compatible, 4.7kΩ to 10kΩ pull-up resistor to Vcc (Host Supply Voltage). Receiver Electrical Interface (Over Operating Case Temperature. VCC = 3.13 to 3.47V) Parameter Differential Output Impedance Differential Output Swing Symbol Minimum Typical Maximum Units Zd - 100 - Ω VPP-DIFF 300 - 850 mV tRH, tFH 28 - - ps Output HIGH Voltage (LOS) 1 VOH VCC - 1.3 - VCC + 0.3 V Output LOW Voltage (LOS) 1 VOL 0 - 0.8 V Output Rise and Fall time (20% to 80%) 1 Open collector compatible, 4.7kΩ to 10kΩ pull-up resistor to Vcc (Host Supply Voltage). Electrical Power Supply Characteristics (Over Operating Case Temperature. VCC = 3.13 to 3.47V) Parameter Symbol Minimum Typical Maximum Units Power Supply Voltage VCC 3.13 3.30 3.47 V DC Common Mode Voltage VCM 0 - 3.6 V Supply Current I VCC - 310 - mA Power Consumption PW - 1.0 - W Note: The specified characteristics are met within the recommended range of operation. Unless otherwise noted typical data are quoted at nominal voltage and +25°C ambient temperature. Connector Pin-out TOWARD HOST Oplink Communications, Inc 11 VEER 12 RD- 13 RD+ 14 VEER 15 VCCR 16 VCCT 17 VEET 18 TD+ 19 TD- 20 VEET VEER 10 RS1 9 RX_LOS 8 RS0 7 MOD-ABS 6 SCL 5 SDA 4 TX_DISABLE 3 TX_FAULT 2 VEET 1 3 TOWARD BEZEL S0217. Rev.02 (web) 2014-02-24 TPD1XGJERxx Module Pin Description Pin Logic Symbol Description 1 - VeeT 2 LVTTL-O TX_Fault 3 LVTTL-I TX_Disable 4 LVTTL-I/O SDA 2-Wire Serial Interface Data Line 5 LVTTL-I/O SCL 2-Wire Serial Interface Clock 6 - MOD-ABS 7 LVTTL-I RS0 8 LVTTL-O RX_LOS 9 LVTTL-I RS1 No function implemented 10 - VeeR Module Receiver Ground 11 - VeeR Module Receiver Ground 12 CML-O RD- Receiver Inverted Data Output 13 CML-O RD+ Receiver Data Output 14 - VeeR Module Receiver Ground 15 - VccR Module Receiver 3.3V Supply 16 - VccT Module Transmitter 3.3V Supply 17 - VeeT Module Transmitter Ground 18 CML-I TD+ Transmitter Non-Inverted Data Input 19 CML-I TD- Transmitter Inverted Data Input 20 - VeeT Module Transmitter Ground Module Transmitter Ground Module Transmitter Fault Transmitter Disable; Turns off transmitter laser output Module Definition, Grounded in the module No function implemented Receiver Loss of Signal Indication Application Notes Electrical Interface: All signal interfaces are compliant with the SFP+ MSA specification. The high speed DATA interface is differential AC-coupled internally and can be directly connected to a 3.3V SERDES IC. All low speed control and sense output signals are open collector TTL compatible and should be pulled up with a 4.7kΩ - 10kΩ resistor on the host board. 2-wrie serial interface. Upon power up, the 2-wrie interface appears as NC (no connection), and MOD_ABS is TTL LOW. When the host system detects this condition, it activates the serial protocol (standard two-wire I2C serial interface) and generates the serial clock signal (SCL). The positive edge clocks data into the EEPROM segments of the device that are not write protected, and the negative edge clocks data from the device. The serial data signal (SDA) is for serial data transfer. The host uses SDA in conjunction with SCL to mark the start and end of serial protocol activation. The supported monitoring functions are temperature, voltage, bias current, transmitter power, average receiver signal, all alarms and warnings, and software monitoring of TX Fault/LOS. The device is internally calibrated. Loss of Signal (LOS): The Loss of Signal circuit monitors the level of the incoming optical signal and generates logic HIGH when an insufficient photocurrent is produced. TX_Fault: The output indicates LOW when the transmitter is operating normally and HIGH with a laser fault including laser end-of-life. TX Fault is an open collector/drain output and should be pulled up with a 4.7kΩ - 10kΩ resistor on the host board. The data transfer protocol and the details of the mandatory and vendor specific data structures are defined in the SFP MSA, and SFF-8472, Rev. 10.4. TX_Disable: When the TX Disable pin is at logic HIGH, the transmitter optical output is disabled. The laser is also disabled if this line is left floating, as it is pulled high inside the transceiver. Power Supply and Grounding: The power supply line should be well-filtered. All power supply bypass capacitors should be as close to the transceiver module as possible. Serial Identification and Monitoring: The module definition of SFP is indicated by the MOD_ABS pin and the Oplink Communications, Inc 4 S0217. Rev.02 (web) 2014-02-24 TPD1XGJERxx Interfacing the Transceivers Communication is via a serial 2-wire serial interface. As described in the document SFF-8472 (REV. 10.4) there are two distinct address spaces: Base Address A0(hex) Byte Address Base Address A2(hex) Byte Address Content Content 0 – 95 Serial Transceiver ID as defined in SFP MSA 0 - 55 Alarm & Warnings thresholds & limits 96 – 127 OPLINK Specific 56 - 95 External calibration constants (not used) 128 – 255 Reserved 96 – 119 Values from real time diagnostic monitoring 120 – 127 Not used 128 – 247 Customer specific, writable area 248 - 255 Not used Application Schematics Recommended electrical connections to transceiver are shown below. TD+ 50Ω line 4.7µH +3.3V 0.1µF + 22µF 0.1µF VccR TDRD+ 50Ω line RD- 50Ω line 4.7µH +3.3V 0.1µF + 22µF 0.1µF VccT 50Ω line ASIC/ SerDes SFP+ +3.3V R SCL, SDA, MOD_ABS TX_Fault +3.3V R +3.3V R RX_LOS VeeT, VeeR R: 4.7kΩ to 10kΩ ESD & Electromagnetic Compatibility Requirements Standard Status Electro Static Discharge to the Electrical Pins (ESD) EIA/JESD22-A114-B MIL-STD 883C Method 3015.7 Exceeds requirements Class 1B (>1000V) Immunity to ESD (housing, receptacle) IEN 61000-4-2 Exceeds requirements Discharges ranging from 2kV to 15kV without damages to the transceiver Electromagnetic Emission (EMI) FCC Part 15, Class B EN 55022 Class B CISPR 22 Exceeds requirements Class B Oplink Communications, Inc 5 S0217. Rev.02 (web) 2014-02-24 TPD1XGJERxx Package Outline Dimensions in [inches] mm Millimeters are the primary units. Tolerances are in accordance with SFF-8432 Rev.5 Ordering Information Model Name Operating Temperature Center Wavelength (nm) ITU Frequency (THz) Wavelength Reference Distance TPD1XGJERC00061G - 5°C to +70°C Commercial 1528.77 196.1 61 40km TPD1XGJERC00060G - 5°C to +70°C Commercial 1529.55 196.0 60 40km TPD1XGJERC00059G - 5°C to +70°C Commercial 1530.33 195.9 59 40km TPD1XGJERC00058G - 5°C to +70°C Commercial 1531.12 195.8 58 40km TPD1XGJERC00057G - 5°C to +70°C Commercial 1531.90 195.7 57 40km TPD1XGJERC00056G - 5°C to +70°C Commercial 1532.68 195.6 56 40km TPD1XGJERC00055G - 5°C to +70°C Commercial 1533.47 195.5 55 40km TPD1XGJERC00054G - 5°C to +70°C Commercial 1534.25 195.4 54 40km TPD1XGJERC00053G - 5°C to +70°C Commercial 1535.04 195.3 53 40km TPD1XGJERC00052G - 5°C to +70°C Commercial 1535.82 195.2 52 40km TPD1XGJERC00051G - 5°C to +70°C Commercial 1536.61 195.1 51 40km TPD1XGJERC00050G - 5°C to +70°C Commercial 1537.40 195.0 50 40km TPD1XGJERC00049G - 5°C to +70°C Commercial 1538.19 194.9 49 40km TPD1XGJERC00048G - 5°C to +70°C Commercial 1538.98 194.8 48 40km TPD1XGJERC00047G - 5°C to +70°C Commercial 1539.77 194.7 47 40km TPD1XGJERC00046G - 5°C to +70°C Commercial 1540.56 194.6 46 40km TPD1XGJERC00045G - 5°C to +70°C Commercial 1541.35 194.5 45 40km Oplink Communications, Inc 6 S0217. Rev.02 (web) 2014-02-24 TPD1XGJERxx Model Name Operating Temperature Center Wavelength (nm) ITU Frequency (THz) Wavelength Reference Distance TPD1XGJERC00044G - 5°C to +70°C Commercial 1542.14 194.4 44 40km TPD1XGJERC00043G - 5°C to +70°C Commercial 1542.94 194.3 43 40km TPD1XGJERC00042G - 5°C to +70°C Commercial 1543.73 194.2 42 40km TPD1XGJERC00041G - 5°C to +70°C Commercial 1544.53 194.1 41 40km TPD1XGJERC00040G - 5°C to +70°C Commercial 1545.32 194.0 40 40km TPD1XGJERC00039G - 5°C to +70°C Commercial 1546.12 193.9 39 40km TPD1XGJERC00038G - 5°C to +70°C Commercial 1546.92 193.8 38 40km TPD1XGJERC00037G - 5°C to +70°C Commercial 1547.72 193.7 37 40km TPD1XGJERC00036G - 5°C to +70°C Commercial 1548.51 193.6 36 40km TPD1XGJERC00035G - 5°C to +70°C Commercial 1549.32 193.5 35 40km TPD1XGJERC00034G - 5°C to +70°C Commercial 1550.12 193.4 34 40km TPD1XGJERC00033G - 5°C to +70°C Commercial 1550.92 193.3 33 40km TPD1XGJERC00032G - 5°C to +70°C Commercial 1551.72 193.2 32 40km TPD1XGJERC00031G - 5°C to +70°C Commercial 1552.52 193.1 31 40km TPD1XGJERC00030G - 5°C to +70°C Commercial 1553.33 193.0 30 40km TPD1XGJERC00029G - 5°C to +70°C Commercial 1554.13 192.9 29 40km TPD1XGJERC00028G - 5°C to +70°C Commercial 1554.94 192.8 28 40km TPD1XGJERC00027G - 5°C to +70°C Commercial 1555.75 192.7 27 40km TPD1XGJERC00026G - 5°C to +70°C Commercial 1556.55 192.6 26 40km TPD1XGJERC00025G - 5°C to +70°C Commercial 1557.36 192.5 25 40km TPD1XGJERC00024G - 5°C to +70°C Commercial 1558.17 192.4 24 40km TPD1XGJERC00023G - 5°C to +70°C Commercial 1558.98 192.3 23 40km TPD1XGJERC00022G - 5°C to +70°C Commercial 1559.79 192.2 22 40km TPD1XGJERC00021G - 5°C to +70°C Commercial 1560.61 192.1 21 40km TPD1XGJERC00020G - 5°C to +70°C Commercial 1561.42 192.0 20 40km TPD1XGJERC00019G - 5°C to +70°C Commercial 1562.23 191.9 19 40km TPD1XGJERC00018G - 5°C to +70°C Commercial 1563.05 191.8 18 40km TPD1XGJERC00017G - 5°C to +70°C Commercial 1563.86 191.7 17 40km Center Wavelength (nm) ITU Frequency (THz) Wavelength Reference Distance Model Name Operating Temperature TPD1XGJERE00061G - 5°C to +85°C Extended 1528.77 196.1 61 40km TPD1XGJERE00060G - 5°C to +85°C Extended 1529.55 196.0 60 40km TPD1XGJERE00059G - 5°C to +85°C Extended 1530.33 195.9 59 40km TPD1XGJERE00058G - 5°C to +85°C Extended 1531.12 195.8 58 40km TPD1XGJERE00057G - 5°C to +85°C Extended 1531.90 195.7 57 40km TPD1XGJERE00056G - 5°C to +85°C Extended 1532.68 195.6 56 40km TPD1XGJERE00055G - 5°C to +85°C Extended 1533.47 195.5 55 40km TPD1XGJERE00054G - 5°C to +85°C Extended 1534.25 195.4 54 40km TPD1XGJERE00053G - 5°C to +85°C Extended 1535.04 195.3 53 40km TPD1XGJERE00052G - 5°C to +85°C Extended 1535.82 195.2 52 40km TPD1XGJERE00051G - 5°C to +85°C Extended 1536.61 195.1 51 40km TPD1XGJERE00050G - 5°C to +85°C Extended 1537.40 195.0 50 40km Oplink Communications, Inc 7 S0217. Rev.02 (web) 2014-02-24 TPD1XGJERxx Model Name Operating Temperature Center Wavelength (nm) ITU Frequency (THz) Wavelength Reference Distance TPD1XGJERE00049G - 5°C to +85°C Extended 1538.19 194.9 49 40km TPD1XGJERE00048G - 5°C to +85°C Extended 1538.98 194.8 48 40km TPD1XGJERE00047G - 5°C to +85°C Extended 1539.77 194.7 47 40km TPD1XGJERE00046G - 5°C to +85°C Extended 1540.56 194.6 46 40km TPD1XGJERE00045G - 5°C to +85°C Extended 1541.35 194.5 45 40km TPD1XGJERE00044G - 5°C to +85°C Extended 1542.14 194.4 44 40km TPD1XGJERE00043G - 5°C to +85°C Extended 1542.94 194.3 43 40km TPD1XGJERE00042G - 5°C to +85°C Extended 1543.73 194.2 42 40km TPD1XGJERE00041G - 5°C to +85°C Extended 1544.53 194.1 41 40km TPD1XGJERE00040G - 5°C to +85°C Extended 1545.32 194.0 40 40km TPD1XGJERE00039G - 5°C to +85°C Extended 1546.12 193.9 39 40km TPD1XGJERE00038G - 5°C to +85°C Extended 1546.92 193.8 38 40km TPD1XGJERE00037G - 5°C to +85°C Extended 1547.72 193.7 37 40km TPD1XGJERE00036G - 5°C to +85°C Extended 1548.51 193.6 36 40km TPD1XGJERE00035G - 5°C to +85°C Extended 1549.32 193.5 35 40km TPD1XGJERE00034G - 5°C to +85°C Extended 1550.12 193.4 34 40km TPD1XGJERE00033G - 5°C to +85°C Extended 1550.92 193.3 33 40km TPD1XGJERE00032G - 5°C to +85°C Extended 1551.72 193.2 32 40km TPD1XGJERE00031G - 5°C to +85°C Extended 1552.52 193.1 31 40km TPD1XGJERE00030G - 5°C to +85°C Extended 1553.33 193.0 30 40km TPD1XGJERE00029G - 5°C to +85°C Extended 1554.13 192.9 29 40km TPD1XGJERE00028G - 5°C to +85°C Extended 1554.94 192.8 28 40km TPD1XGJERE00027G - 5°C to +85°C Extended 1555.75 192.7 27 40km TPD1XGJERE00026G - 5°C to +85°C Extended 1556.55 192.6 26 40km TPD1XGJERE00025G - 5°C to +85°C Extended 1557.36 192.5 25 40km TPD1XGJERE00024G - 5°C to +85°C Extended 1558.17 192.4 24 40km TPD1XGJERE00023G - 5°C to +85°C Extended 1558.98 192.3 23 40km TPD1XGJERE00022G - 5°C to +85°C Extended 1559.79 192.2 22 40km TPD1XGJERE00021G - 5°C to +85°C Extended 1560.61 192.1 21 40km TPD1XGJERE00020G - 5°C to +85°C Extended 1561.42 192.0 20 40km TPD1XGJERE00019G - 5°C to +85°C Extended 1562.23 191.9 19 40km TPD1XGJERE00018G - 5°C to +85°C Extended 1563.05 191.8 18 40km TPD1XGJERE00017G - 5°C to +85°C Extended 1563.86 191.7 17 40km Center Wavelength (nm) ITU Frequency (THz) Wavelength Reference Distance Model Name Operating Temperature TPD1XGJERI00061G -40°C to +85°C Industrial 1528.77 196.1 61 40km TPD1XGJERI00060G -40°C to +85°C Industrial 1529.55 196.0 60 40km TPD1XGJERI00059G -40°C to +85°C Industrial 1530.33 195.9 59 40km TPD1XGJERI00058G -40°C to +85°C Industrial 1531.12 195.8 58 40km TPD1XGJERI00057G -40°C to +85°C Industrial 1531.90 195.7 57 40km TPD1XGJERI00056G -40°C to +85°C Industrial 1532.68 195.6 56 40km TPD1XGJERI00055G -40°C to +85°C Industrial 1533.47 195.5 55 40km Oplink Communications, Inc 8 S0217. Rev.02 (web) 2014-02-24 TPD1XGJERxx 46335 Landing Pkwy Fremont, CA 94538 Tel: (510) 933-7200 Fax: (510) 933-7300 Email: [email protected] • www.oplink.com Model Name Operating Temperature Center Wavelength (nm) ITU Frequency (THz) Wavelength Reference Distance TPD1XGJERI00054G -40°C to +85°C Industrial 1534.25 195.4 54 40km TPD1XGJERI00053G -40°C to +85°C Industrial 1535.04 195.3 53 40km TPD1XGJERI00052G -40°C to +85°C Industrial 1535.82 195.2 52 40km TPD1XGJERI00051G -40°C to +85°C Industrial 1536.61 195.1 51 40km TPD1XGJERI00050G -40°C to +85°C Industrial 1537.40 195.0 50 40km TPD1XGJERI00049G -40°C to +85°C Industrial 1538.19 194.9 49 40km TPD1XGJERI00048G -40°C to +85°C Industrial 1538.98 194.8 48 40km TPD1XGJERI00047G -40°C to +85°C Industrial 1539.77 194.7 47 40km TPD1XGJERI00046G -40°C to +85°C Industrial 1540.56 194.6 46 40km TPD1XGJERI00045G -40°C to +85°C Industrial 1541.35 194.5 45 40km TPD1XGJERI00044G -40°C to +85°C Industrial 1542.14 194.4 44 40km TPD1XGJERI00043G -40°C to +85°C Industrial 1542.94 194.3 43 40km TPD1XGJERI00042G -40°C to +85°C Industrial 1543.73 194.2 42 40km TPD1XGJERI00041G -40°C to +85°C Industrial 1544.53 194.1 41 40km TPD1XGJERI00040G -40°C to +85°C Industrial 1545.32 194.0 40 40km TPD1XGJERI00039G -40°C to +85°C Industrial 1546.12 193.9 39 40km TPD1XGJERI00038G -40°C to +85°C Industrial 1546.92 193.8 38 40km TPD1XGJERI00037G -40°C to +85°C Industrial 1547.72 193.7 37 40km TPD1XGJERI00036G -40°C to +85°C Industrial 1548.51 193.6 36 40km TPD1XGJERI00035G -40°C to +85°C Industrial 1549.32 193.5 35 40km TPD1XGJERI00034G -40°C to +85°C Industrial 1550.12 193.4 34 40km TPD1XGJERI00033G -40°C to +85°C Industrial 1550.92 193.3 33 40km TPD1XGJERI00032G -40°C to +85°C Industrial 1551.72 193.2 32 40km TPD1XGJERI00031G -40°C to +85°C Industrial 1552.52 193.1 31 40km TPD1XGJERI00030G -40°C to +85°C Industrial 1553.33 193.0 30 40km TPD1XGJERI00029G -40°C to +85°C Industrial 1554.13 192.9 29 40km TPD1XGJERI00028G -40°C to +85°C Industrial 1554.94 192.8 28 40km TPD1XGJERI00027G -40°C to +85°C Industrial 1555.75 192.7 27 40km TPD1XGJERI00026G -40°C to +85°C Industrial 1556.55 192.6 26 40km TPD1XGJERI00025G -40°C to +85°C Industrial 1557.36 192.5 25 40km TPD1XGJERI00024G -40°C to +85°C Industrial 1558.17 192.4 24 40km TPD1XGJERI00023G -40°C to +85°C Industrial 1558.98 192.3 23 40km TPD1XGJERI00022G -40°C to +85°C Industrial 1559.79 192.2 22 40km TPD1XGJERI00021G -40°C to +85°C Industrial 1560.61 192.1 21 40km TPD1XGJERI00020G -40°C to +85°C Industrial 1561.42 192.0 20 40km TPD1XGJERI00019G -40°C to +85°C Industrial 1562.23 191.9 19 40km TPD1XGJERI00018G -40°C to +85°C Industrial 1563.05 191.8 18 40km TPD1XGJERI00017G -40°C to +85°C Industrial 1563.86 191.7 17 40km Oplink Communications, Inc. reserves the right to make changes in equipment design or specifications without notice. Information supplied by Oplink Communications, Inc. is believed to be accurate and reliable. However, no responsibility is assumed by Oplink Communications, Inc. for its use nor for any infringements of third parties, which may result from its use. No license is granted by implication or otherwise under any patent right of Oplink Communications, Inc. © 2014, Oplink Communications, Inc. 9 S0217. Rev.02 (web) 2014-02-24