Maintenance-Free Rechargeable Sealed Lead-Acid Battery HR15-12 (60W/Cell 15Min Rate) For High Rate Discharge The battery is constructed by plates, separators, safety valves and container Since the electrolyte is held by a glass-mat separator and plates ,the battery can use in any direction and position without leakage. PERFORMANCE SPECIFICATIONS Nominal Voltage(V).........................................................................................................................12 volts(6cells in series) Nominal Capacity(AH) 10 Hour rate F.V.(1.75V/cell) (1.3A to 10.50volts) ..............................................................................................13.0A.H. 15 Min rate F.V.(1.30V/cell) (360W to 7.80volts) ...............................................................................................7.50A.H. Approximate Weight .....................................................................................................................................4200g(9.25lbs.) Terminal Standard................................................................................................................................................................Type T2 Optional..................................................................................................................................................................Type T1 Internal Resistance (Fully Charged Battery)..............................................................................................................<12m Maximum Discharge Current For 5 sec.(A)...................................................................................................................180A Maximum Charge Current(A)..........................................................................................................................................3.9A Ambient Temperature Charge..........................................................................................................................................0OC(32OF)~40OC(104OF) Discharge...................................................................................................................................-20OC(-4OF)~50OC(122OF) storage.......................................................................................................................................-20OC(-4OF)~40OC(104OF) Vibration test: Frequency: 16.7HZ Amplitude: 4mm vibrate the battery horizontally or vertically for 60 minutes. The battery have no abnormality. Case.................................................................................................................................................................................ABS Dimension(mm/inch) Length 1.5mm.....................................................................................................................................151/5.94 Width 1.5mm.......................................................................................................................................98/3.86 Container Height 1.5mm........................................................................................................................................94/3.70 Total Height 2mm...........................................................................................................................................98/3.86 Application..................................................................................................................... ..UPS, Fishing Lights, Power Pack. HR15-12 Battery discharge characteristics(25 O C/77 O F) Battery Charging Characteristics (Typical example of the charge characteristic for the standby use) 11.0 2.21A 1.30A 3.25A 10.0 7.8A 9.0 0.21 15.0 120 0.18 14.0 0.15 13.0 100 80 60 40 0.12 0.09 0.06 20 0.03 0 0 Charge voltage(V) Charge volume(%) Terminal voltage(V) 12.0 140 Charge current(CA) 13.0 Charge voltage C ha rg e vo lu m e 1 Discharge 100 %(0.1CA x 10h) 50 %(0.1CA x 5h) 2 Constant voltage charging Charge voltage:2.275V/cell Charge current:0.1CA O O 3 Temperature 20 C(68 F) 12.0 11.0 10.0 8.0 Charge current 65A 52A 39A 26A 7.0 1 2 3 5 10 20 13A 30 60 3 2 10 5 0 0 10 5 20 15 25 Charge time (hr) 20 Hr Min DISCHARGE TIME Effect of Temperature on Long Term Float Life 10 Charging Procedure Charging method Constant For standby voltage & power Source Constant current charging For (with current cycle service restrication) Charging Voltage o at 20 C (V/cell) 2.25~2.30 2.40~2.50 Temperature compensation coefficient of charging voltage (mV/ o C/cell) Charging time 0.1CA, 20 o C (h) Max. charging current (CA) 100% discharge -3 24 0.3 -4 0.3 16 6 5 Life expectancy(year) Application 8 50% discharge 20 Charging voltage : 2.275V/cell 4 3 2 1 10 0.5 20 68 *Temperature compensation of charging voltage is not needed,when using the batteries within5 o C to 35 o C range. 30 86 40 104 o 50 122 C F o Battery temperature OUTER DIMENSIONS TERMINAL TYPE mm(inch) mm(inch) 6.35(0.25) Terminal T2 2 (3.86 0.08) 3.4(0.13) 7.85(0.31) 98 1.5(3.86 0.06) 94 1.5(3.70 0.06) 151 1.5(5.95 0.06) 0.8(0.03) 3.2(0.13) 6.35(0.25) 0.8(0.03) 4.75(0.187) Discharge time Terminal T1 98 Constant power discharge characteristics at 25OC/77 OF Final Voltage 5Min 10Min 15Min 20Min 30Min 40Min 50Min 60Min Battery output power(W) 10.80V 615.0 420.0 304.1 259.5 197.3 150.0 125.3 110.3 10.20V 735.0 468.8 330.8 274.9 205.5 155.6 129.4 112.9 9.60V 787.5 493.1 345.8 285.0 210.0 159.4 132.0 114.8 9.00V 810.0 502.5 353.3 289.5 212.6 161.3 133.5 115.9 8.40V 825.0 509.3 357.4 292.1 214.1 162.4 134.6 116.6 7.80V 832.5 513.8 360.0 294.0 215.3 163.1 135.4 117.0 TERMINAL POSITION UL R MH19884 B.B. BATTERY CO., LTD. Web Site: http://www.bb-battery.com USA : B&B BATTERY (USA) INC. 6415 RANDOLPH ST. COMMERCE, CA, 90040 U.S.A. TEL: 1-323-278-1900 . 1-800-278-8599 FAX: 1-323-278-1268 CHINA FACTORY: CHENG DONG TRIAL AREA, HUANG GANG, RAOPING GUANG DONG, CHINA, 515700 TEL: 86-768-7601001-2 FAX: 86-768-7601469 UK: JAPAN: B & B BATTERY (UK) CO., LTD. TEL: 44-161-339-9458 FAX: 44-161-343-7030 B & B BATTERY(JAPAN) CO., LTD. TEL: 81-426-256-537 FAX: 81-426-256-537 HONG KONG: TAIWAN: NATIONAL TRADING LTD. B & B BATTERY CO., LTD. TEL: 852-2301-3800 FAX: 852-2739-1182 TEL: 886-6-5898081~3 FAX: 886-6-5898087 QUALITY ASSURED FIRM NATIONAL ACCREDITATION OF CERTIFICATION BODIES I S O 1 4 0 0 1 UKAS ENVIRONMENTAL MANAGEMENT Reg. No. 059-C