DC-AC INVERTER UNIT PS-M06D05S5-NJ5R-003(S) (6,5 W DUAL OUTPUTS) (PRELIMINARY INFORMATION) DESCRIPTION : This low profile DC/AC inverter is developed for dual lamps. Optimized for the AUO: B104SN02 and G104SN02 APPLICABLE LCD: 6.4 to 12 inches type double lamps Lamp voltage 540 Vrms Lamp current 6 mArms Lamp Start Up Voltage 1.300 Vrms (Vin : 5 Vdc) FEATURES : Remote ON/OFF Ext. PWM dimming function RoHS compliant (S) TEMPERATURE & HUMIDITY : Operating Temperature Range Storage Temperature Range Humidity DIMENSIONS : LxWxH 105 x 22,5 x 10mm 13 ± 0.5 PS-MXXDXX-NJX 29/01/2004 MADE IN GERMANY CN1 CN1-1 CN2 5 ± 0.5 105 ± 0.5 82 ± 0.3 (2) 15 ± 0.3 22,5 ± 0.5 0°C ~ +60°C -20°C ~ +85°C 95 %RH max CAUTION HIGH VOLTAGE CN2-1 CN1-5 10.0MAX CN2-4 3 2 - Ø2.5 ± 0.2 (for M2 screws) 2 (2) 1 Unit : mm Weight :20 (g) typ. High Voltage generation area 60mm Note: Please use plastic screw in case of a non-insulating mounting base! Components No. 1 2 3 Part Description PCB Connector CN1 Connector CN2 Input side CN1: Pin No. Symbols Vin CN 1-1 GND CN 1-2 CN 1-3 Ext. PWM N.C. CN 1-4 CN 1-5 Vrm t Qty. 1 1 1 Material UL94V-0 (FR-4 or CEM-3) S5B-PH-SM3 SM03(4.0)B-BHS Note t=1m m JST or equal JST or equal Output side CN2: Pin No. CN 2-1 CN 2-2+3 Ratings 5 Vdc Symbols Vlow Vhigh Ratings 540 Vrm s (6 m Arm s ) 0 Vdc 0 / 5 Vdc (L activ) 0 / 5 Vdc (H activ) Power Systems – The Power Solution Web: Email: www.Power-Systems.de [email protected] All specifications are subject to change without notice. Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Page (1) Version 1.4.1, 20th May 2014 DC-AC INVERTER UNIT PS-M06D05S5-NJ5R-003(S) (6,5 W DUAL OUTPUTS) (PRELIMINARY INFORMATION) ELECTRICAL CHARACTERISTICS : Parameters Symbols Output Current Output Current Input Current Frequency Open Circuit Voltage Iout1+2 Iout1+2 Iin F Vopen Dimming Function Ext PWM Note 1 : Note 2: Note 3: Conditions Vrmt Vin (V) Tu (°C) (V) 5±1.2 5±0.25 0 ~ +60 5±0.6 5±0.25 0 ~ +60 5±1.2 5±0.25 0 ~ +60 5±1.2 5±0.25 0 ~ +60 4.7 5±0.25 0 ~ +60 0/5 Specification Unit Min. Typ. Max. 5.5 5.0 TBD 1.200 6.0 6.0 0.7 50 1.300 6.5 7.0 1.2 TBD - m Arm s m Arm s Adc kHz Vrm s 5.5 6.0 6.5 m Arm s 5±0.25 0 ~ +60 Note Dut y Circle variable Please keep a minimum of 2mm clearance in all directions between inverter high voltage areas and any conductors. Remote ON/OFF (CN1-5) has priority and can not be used in combination with External PWM Dimming (CN1-3). When 'Ext.PWM' (CN1-3) is used 'Vrmt' (CN1-5) should not be connected. The external PWM-frequency should be within the range of 100 ~ 500Hz. For other frequencies please request. The optimum frequency is normally 250 Hz and this minimizes the interference of the vertical sync frequency. TEST CIRCUIT : F Vin 5V A Iin 1000:1 PROBE F Vopen V ~ CN1-1 SW3 V SW 1 Operation of unit a Operation b Non operation CN2-1 CN1-2 SW4 CN1-3 T1 CN2-2 RL2 RL1 Ext. PWM* 0/5V CL2 A NC Vrmt 2.5 Vdc ~ Vin SW5 a V b CL1 A ~ Iout ~ Iout1 2 CN1-4 CN2-3 SW1 CN1-5 *) Only active when Vrmt is 0 Vdc or floating EXTERNAL PWM-DIMMING ( Remote ON / OFF Detailed Circuit Diagram ): Power Systems – The Power Solution Web: Email: www.Power-Systems.de [email protected] All specifications are subject to change without notice. Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Page (2) Version 1.4.1, 20th May 2014