POWER-SYSTEMS PS-M07D12S4-NJ5R-137S

DC-AC INVERTER UNIT
PS-M07D12S4-NJ5R-137(S) (6,5 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
DESCRIPTION :
This low profile DC to AC Inverter is developed for dual lamps.
Optimized for Chi Mei: G104X1-L01
APPLICABLE LCD:
6.4 to 12 inches double lamp type
Lamp Voltage 460 Vrms
Lamp Current 7 mArms
Lamp Start Up Voltage 1.300 Vrms (Vin : 12 Vdc)
FEATURES :
Remote ON/OFF
Ext. PWM-Dimming Function
RoHS compliant (S)
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
LxWxH
105 x 22,5 x 10mm
CN2
CN1
15 ± 0.3
22,5 ± 0.5
5 ± 0.5
DIMENSIONS :
-10°C ~ +55°C
-20°C ~ +85°C
95 %RH max
10.0MAX
Unit : mm
Weight :20 (g) typ.
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
Part Description
PCB
Connector CN1
Qty.
1
1
Material
UL94V-0 (FR-4 or CEM-3)
S5B-PH-SM3
Note
t=1.6m m
JST or equal
3
Connector CN2
1
SM03(4.0)B-BHS
JST or equal
Input side CN1:
Pin No.
CN 1-1
CN 1-2
CN 1-3
CN 1-4
Symbols
Vin
GND
Ext. PWM
N.C.
CN 1-5
Vrm t
Output side CN2:
Ratings
12 Vdc
Pin No.
CN 2-1
CN 2-2
Symbols
VLOW
VHIGH1
Ratings
0Vdc
460Vrm s (7m Arm s )
0 ~ 5 Vdc (L activ)
CN 2-3
VHIGH2
460Vrm s (7m Arm s )
0 / 5 Vdc (H activ)
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 1.0, 1st June 2007
DC-AC INVERTER UNIT
PS-M07D12S4-NJ5R-137(S) (6,5 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
ELECTRICAL CHARACTERISTICS :
Parameters
Symbols
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
Note 1 :
Specification
Min.
Typ.
Max.
Tu (°C)
Iout
12±0.12
5±0.25
-10 ~ +55
Iout
Iin
F
Vopen
12±1.2
12±1.2
12±1.2
11,4
5±0.25
5±0.25
5±0.25
5±0.25
-10
-10
-10
-10
6.5
~ +55
6.0
~ +55
~ +55
45
~ +55 1.200
Unit
7.0
7.5
m Arm s
7.0
0.7
50
1.300
8.0
1.2
55
-
m Arm s
Adc
kHz
Vrm s
Note
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
Remote ON/OFF (CN1-5) has priority and can not be used in combination with External PWM Dimming
(CN1-3). When 'Ext.PWM' (CN1-3) is used 'Vrmt' (CN1-5) should not be connected.
The external PWM frequency should be in a range of 100 ~ 500 Hz. For other frequency please request.
The optimum is 250 Hz. Here you will normally not get a interference to the vertical sync. frequency.
Note 2:
Note 3:
F
TEST CIRCUIT :
Vin
12 V
Conditions
Vrmt (V)
Vin (V)
A
Iin
1000:1
PROBE
F
Vopen V
~
CN1-1
SW 1
SW3
V
Operation
b
Non operation
CN2-3
CN1-2
Operation of unit
a
SW4
CN1-3
T1
CN2-2
RL2
Ext. PWM*
0/5V
RL1
CL2
A
NC
Vrmt
2.5 Vdc ~ Vin
SW5
a
V
b
CL1
A
~
Iout ~
Iout1
2
CN1-4
CN2-1
SW1
CN1-5
*) Only active when Vrmt is 0 Vdc or floating
EXTERNAL PWM-DIMMING ( Remote ON / OFF Detailed Circuit Diagram ):
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)
Version 1.0, 1st June 2007