MA-COM MAAM

MAAM-009450
Broadband CATV 3-Way Active Splitter with default loop-through Switch
50 - 1100 MHz
Functional Schematic, Default On, Power Off
Features
•
•
•
•
•
•
•
Rev. V3
Always ON loop-thru path
3-Way Splitter
3.0 dB Gain
+15 dBmV /Channel Input
3.8 dB Noise Figure
Lead-Free 3 mm 12-Lead PQFN Package
RoHS* Compliant and 260°C Reflow Compatible
Description
The MAAM-009450 CATV 3-way active splitter with
the default loop-through path is a GaAs MMIC which
exhibits low noise figure and distortion in a lead-free
3mm 12-lead PQFN plastic package. The design
features 75 Ω inputs and outputs.
Functional Schematic, Power On
The MAAM-009450 is ideally suited for multi-tuner
set top boxes, home gateways, and other broadband
internet based applications.
The MAAM-009450 is fabricated using MACOM’s
E/D pHEMT process to realize default loop-through
operation, low noise and low distortion. The process
features full passivation for robust performance and
reliability.
Pin Configuration3
Ordering Information 1,2
Part Number
Package
MAAM-009450-TR1000
1000 piece reel
MAAM-009450-TR3000
3000 piece reel
MAAM-009450-001SMB
Sample Test Board
Pin No.
Pin Name
Description
1
2
3
VC
IN
OUT3
Voltage Control
RF Input
Loop thru Output
4
5
6
S1
ALT
N/C
Switch In
Alternate Output
No Connection
7
8
9
OUT2
N/C
OUT1
10
FB/VDD
11
AIN
RF Output 2
No Connection
RF Output 1
Amplifier Feedback /
Drain Voltage
Amplifier Input
12
13
S2
Paddle
Switch Output
RF and DC Ground
1. Reference Application Note M513 for reel size information.
2. All sample boards include 5 loose parts.
3. The exposed pad centered on the package bottom must be
connected to RF and DC ground.
1
* Restrictions on Hazardous Substances, European Union Directive 2002/95/EC.
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macomtech.com for additional data sheets and product information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
MAAM-009450
Broadband CATV 3-Way Active Splitter with default loop-through Switch
50 - 1100 MHz
Rev. V3
Electrical Specifications: Freq. = 1000 MHz, TA = 25°C, Z0 = 75 Ω4
Parameter
Test Conditions
VDD
VC
Units
Min.
Typ.
Max.
Gain
IN to Out1, Out2 or Out3
5
3.3
dB
2.0
3.0
5.5
Insertion Loss
IN to Out3
0
0
dB
-
0.75
1.0
Noise Figure
IN to Out1, Out2 or Out3
5
3.3
dB
-
3.8
-
Gain Flatness
IN to Out1, Out2 or Out3
5
3.3
dB
-
1.0
-
Input Return Loss
Input
5
3.3
dB
-
12.5
-
Input Return Loss
Input
0
0
dB
-
12.5
-
Output Return Loss
Output
5
3.3
dB
-
10
-
Output Return Loss
Output
0
0
dB
-
10
-
Out to Out Isolation
Out1 to Out2 or Out3
5
3.3
dB
-
23
-
Out to Out Isolation
Out1 to Out2 or Out3
0
0
dB
-
35
-
5
3.3
dBc
-
-65
-
5
3.3
dBc
-
-65
-
CTB
CSO
132 Ch, +15 dBmV/Channel
at the Input
132 Ch, +15 dBmV/Channel
at the Input
Reverse Isolation
Out1 to In, Out2 to In
5
3.3
dB
-
31
-
Reverse Isolation
Out3 to In
5
3.3
dB
-
23
-
Reverse Isolation
Out1 to In, Out2 to In
0
0
dB
-
45
-
5
3.3/0
dBm
-
42
-
5
3.3/0
dBm
-
20
-
OIP2
OIP3
500 MHz, 2-tone,
6 MHz spacing, -10 dBm Pout
500 MHz, 2-tone,
6 MHz spacing, -10 dBm Pout
P1dB
500 MHz
5
3.3
dBm
-
7
-
P1dB
500 MHz
5
0
dBm
-
25
-
IDD
5
3.3
mA
-
100
130
IC
5
3.3
µA
-
205
250
4. The unpowered state is the same as Vcontrol = 0 V
2
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macomtech.com for additional data sheets and product information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
MAAM-009450
Broadband CATV 3-Way Active Splitter with default loop-through Switch
50 - 1100 MHz
Absolute Maximum Ratings5,6,7
Rev. V3
Truth Table9
VDD
VCONTROL
IN - OUT1 IN - OUT2 IN - OUT3
Max Input Power
+5 dBm
1
1
On
On
On
VDD
+10.0 V
0
0
Off
Off
On
VCONTROL
+8.5 V
Operating Temperature
Junction Temperature
8
Storage Temperature
9. Logic “1” for VDD = +5 volts and VCONTROL = +3.3 volts typical.
-40°C to +85°C
+150°C
-65°C to +150°C
5. Exceeding any one or combination of these limits may cause
permanent damage to this device.
6. M/A-COM does not recommend sustained operation near
these survivability limits.
7. These operating conditions will ensure MTTF > 1 x 106 hours.
8. Junction Temperature (TJ) = TA + Өjc * (V * I)
Typical thermal resistance (Өjc) = 73 °C/W.
a) For TA = 25°C,
TJ = 72 °C @ 5.0 V, 130 mA
b) For TA = 85°C,
TJ = 129 °C @ 5.0 V, 120 mA
Handling Procedures
Please observe the following precautions to avoid
damage:
Static Sensitivity
Gallium Arsenide Integrated Circuits are sensitive
to electrostatic discharge (ESD) and can be
damaged by static electricity. Proper ESD control
techniques should be used when handling these
devices. An external protection circuit using an
inexpensive anti-parallel diode pair can be used to
protect the IC.
Please reference application note AN3028 on
http://www.macomtech.com for further detail.
Schematics Including Off-Chip Components10
Power On Condition
Power Off, Default on Condition
10. The exposed pad centered on the package bottom must be connected to ground for RF, DC and thermal considerations.
3
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macomtech.com for additional data sheets and product information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
MAAM-009450
Broadband CATV 3-Way Active Splitter with default loop-through Switch
50 - 1100 MHz
Recommended PCB
PCB Land Pattern
Block Diagram RF Signal Flow
Off-Chip Component Values
Rev. V3
Component
Value
Package
C1 - C10
0.01 µF
0402
C11
1.0 pF
0402
1 µH
1210
L2 - L5
7.5 nH
0402
R1, R2
300 Ω
0402
R3, R4
180 Ω
0402
R5
250 Ω
0402
R6, R7
22 kΩ
0402
L1
11
11. L1 supplied from EPCOS, part number B82422A1102K100
4
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macomtech.com for additional data sheets and product information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
MAAM-009450
Broadband CATV 3-Way Active Splitter with default loop-through Switch
50 - 1100 MHz
Typical Performance Curves
Gain
Gain
Input Return Loss (power on)
Input Return Loss (power off)
Output Return Loss (power on)
Output Return Loss (power off)
5
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macomtech.com for additional data sheets and product information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Rev. V3
MAAM-009450
Broadband CATV 3-Way Active Splitter with default loop-through Switch
50 - 1100 MHz
Typical Performance Curves
Insertion Loss to 1 GHz (power off)
Insertion Loss to 3 GHz (power off)
Reverse Isolation to 3 GHz (power on)
Reverse Isolation to 3 GHz (power off)
Noise Figure
6
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macomtech.com for additional data sheets and product information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Rev. V3
MAAM-009450
Broadband CATV 3-Way Active Splitter with default loop-through Switch
50 - 1100 MHz
Rev. V3
Typical Performance Curves
Out to Out Isolation to 1 GHz (power on)
Out to Out Isolation to 3 GHz (power on)
out1-out3
out1-out2
out2-out3
out1-out3
out1-out2
out2-out3
Out to Out Isolation to 3 GHz (power off)
Out to Out Isolation to 1 GHz (power off)
out1-out2
out1-out2
out2-out3
out1-out3
out1-out3
out2-out3
7
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macomtech.com for additional data sheets and product information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
MAAM-009450
Broadband CATV 3-Way Active Splitter with default loop-through Switch
50 - 1100 MHz
Lead-Free 3 mm 12-Lead PQFN†
†
Reference Application Note S2083 for lead-free solder reflow recommendations.
Meets JEDEC moisture sensitivity level 1 requirements.
Plating is 100% matte tin plating over copper.
8
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macomtech.com for additional data sheets and product information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Rev. V3