Product datasheet OT 15/220…240/12 P CV Power supplies 12 V Areas of application _ Suitable for indoor and outdoor installations _ Ideal for mounting in very tight spaces __ Product benefits _ Versatile scope of application due to output power range of up to 120 W _ Very high efficiency and reliability _ High IP protection (up to IP67) _ High surge protection: up to 3 kV (L-N) / 6 kV (L/N-PE) May 25, 2016, 17:02:53 OT 15/220…240/12 P © 2016, OSRAM GmbH. All rights reserved. Page 1 of 4 Product datasheet Technical data Electrical data Nominal voltage 220…240 V Mains frequency 50…60 Hz Input voltage AC 198…264 V 1) Power factor λ > 0.5 ECG efficiency 80 % 3) Device power loss 3.0 W Inrush current 20 A 4) Max. ECG no. on circuit breaker 10 A (B) 32 Max. ECG no. on circuit breaker 16 A (B) 51 Max. ECG no. on circuit breaker 25 A (B) - Surge capability (L-N) 4 kV Nominal output voltage 12.5 V 5) Nominal output power 15 W 6) Galvanic isolation SELV equivalent Galvanic isolation primary/secondary 3.75 kV 7) 2) 1) V __ / Permitted voltage range AC 2) Full load at 230 V 3) At full load and 230 V 4) t width 5) ±0.5 V = 170 µs (measured at 50 % I ) peak 6) Partial load 0…15 W 7) SELV-equivalent Dimensions & weight Length 237.0 mm Width 20.0 mm Height 22.0 mm May 25, 2016, 17:02:53 OT 15/220…240/12 P © 2016, OSRAM GmbH. All rights reserved. Page 2 of 4 Product datasheet Mounting hole spacing, length 228.0 mm Product weight 170.00 g Cable cross-section, input side 1.0 mm² 1) Cable cross-section, output side 1.0 mm² 1) Wire preparation length, input side 10 mm Wire preparation length, output side 10 mm Cable/wire length, input side 300 mm Cable/wire length, output side 300 mm 1) Flexible Colors & materials Casing material Plastic Temperatures & operating conditions Ambient temperature range -25…+55 °C Maximum temperature at tc test point 80 °C Max.housing temperature in case of fault 110 °C Permitted rel. humidity during operation 5…85 % Lifespan __ ECG lifetime 50000 h 1) 1) At T = 70°C / 10% failure rate a Additional product data Encapsulated No Capabilities 1) Dimmable No Dimming interface Not dimmable Overheating protection Automatic reversible Overload protection Automatic reversible Short-circuit protection Automatic reversible No-load proof Yes Max. cable length to lamp/LED module 10 m Suitable for fixtures with prot. class II 1) With OPTOTRONIC dimmers Certificates & standards Approval marks – approval May 25, 2016, 17:02:53 OT 15/220…240/12 P CE / ENEC 18 / CB / C-Tick © 2016, OSRAM GmbH. All rights reserved. Page 3 of 4 Product datasheet Standards Acc. to IEC 61347-1/Acc. to IEC 61347-2-13/Acc. to IEC 62384/Acc. to CISPR 15/Acc. to EN 61000-32/Acc. to EN 61547 Protection class II Type of protection IP66 Logistical data Temperature range at storage -40…85 °C Download Data File Product Datasheet Datasheet_OT 15220-24012 P Certificates CB-Certificate OT15 220 240 12P Installation/Operation notice Instruction Sheet_OT 15220-24012 P Logistical Data __ Product code Product description Packaging unit (Pieces/Unit) Dimensions (length x width x height) Volume Gross weight 4052899905559 OT 15/220…240/12 P Shipping carton box 50 356 mm x 309 mm x 209 mm 22.99 dm³ 11035.00 g The mentioned product code describes the smallest quantity unit which can be ordered. One shipping unit can contain one or more single products. When placing an order, for the quantity please enter single or multiples of a shipping unit. Disclaimer Subject to change without notice. Errors and omission excepted. Always make sure to use the most recent release. May 25, 2016, 17:02:53 OT 15/220…240/12 P © 2016, OSRAM GmbH. All rights reserved. Page 4 of 4