product details OT 6/100-120/10 CE Product description: EAN/ Product: Quantity: OT 6/100-120/10 CE 4008321128911 Folding carton box (FS) contains 1 Piece (PCE) Applications Dimmable (for maintenance) Yes 1) Short-circuit protection automatic reversible Overload protection automatic reversible IP code IP65 Overtemperature protection automatic reversible General Description Design / version ECG standard Standards acc. to UL 1310 | acc. to UL 48 | acc. to UL879A | FCC 47 part 15 class B | acc. to ANSI C62.41 Class B | acc. to IEC 1000-4-2 | acc. to IEC 1000-4-5 Logistical Data Product weight 73 g Technical - Electrical Data DC voltage 176...264 V Max. no. of ECGs on circuit breaker 10A 35 TH full width at half maximum 170 µs 2) Max. no. of ECGs on circuit breaker 16A 56 Lamp wattage 6W Power factor λ 0.6 Mains current max. 0.09 A Device power loss ...1.2 W 3) Output voltage 10.5±0.5 V Nominal voltage 100-120 V Nominal wattage + Power loss (caluculate 0 Mains frequency 50-60 Hz Technical - Geometries Length 51 mm Max. cable length - system in meters 10 m Mounting hole spacing, length 25 mm Width 50 mm Mounting hole spacing, width 41 mm Height 22 mm Technical - Temperatures Max. operating temp. at the Tc point 70 °C Max. casing temp. in case of fault 110 °C Storage temperature -40...85 °C Relative humidity 5...85 % 4) Ambient temperature range -20...+50 °C 11.02.2010 Subject to change without notice. Errors and omission excepted. © 2009 OSRAM GmbH Page 1 from 4 product details OT 6/100-120/10 CE Packaging units EAN Packaging type and content Dimensions in h x w x l Gross weight Volume 4008321128911 Folding carton box contains 1 Piece 71,000 mm x 36,000 mm x 72,000 mm 0,000 g (0,000 g) 0,184 Cubic dec. 4008321129123 Shipping carton box contains 20 Piece 156,000 mm x 80,000 mm x 381,000 mm 1.866,000 g (0,000 g) 4,755 Cubic dec. 1) with OPTOTRONIC dimmers 2) at 240 VAC 3) maximum at 230 VAC, Pout=maximum, Ta=25°C, steady state 4) max. 56 d/y at 85% 11.02.2010 Subject to change without notice. Errors and omission excepted. © 2009 OSRAM GmbH Page 2 from 4 Geometry product details OT 6/100-120/10 CE Wiring diagram 11.02.2010 Subject to change without notice. Errors and omission excepted. © 2009 OSRAM GmbH Page 3 from 4 Installations notes product details OT 6/100-120/10 CE Mounting position in distribution box Instruction sheet Please consult the instruction sheet for further important information on dimming characteristic, wire stripping and wiring limitations in system installations. The instruction sheet is available upon request. The luminaire manufacturer is responsible for providing the required clearances and creepage distances and also for the protection against electrical shock, especially for the line and load wires. 11.02.2010 Subject to change without notice. Errors and omission excepted. © 2009 OSRAM GmbH Page 4 from 4