Product datasheet OT 80/220…240/24 P CV Power supplies 24 V Areas of application _ Suitable for indoor and outdoor SELV installations _ Outdoor applications only in suitable installations _ Suitable for use in tight, flat luminaires or installation in suspended ceilings __ Product benefits _ Versatile scope of application due to output power range of up to 240 W _ Very high efficiency and reliability _ Constant luminous flux for very low and high temperatures due to Smart Power Supply June 8, 2016, 11:15:11 OT 80/220…240/24 P © 2016, OSRAM GmbH. All rights reserved. Page 1 of 5 Product datasheet Technical data Electrical data __ Nominal voltage 220…240 V Mains frequency 50…60 Hz Input voltage AC 198…264 V 1) Total harmonic distortion < 20 % Power factor λ 0.90/0.95 ECG efficiency 87 % 3) Device power loss 12 W 4) Protective conductor current <2.0 mA Inrush current 35 A 5) Max. ECG no. on circuit breaker 10 A (B) 7 Max. ECG no. on circuit breaker 16 A (B) 10 Max. ECG no. on circuit breaker 25 A (B) - Surge capability (L-N) 3 kV Nominal output voltage 24 V 6) U-OUT (working voltage) 24 V Nominal output power 80 W 7) Galvanic isolation SELV equivalent Galvanic isolation primary/secondary 3.75 kV 8) 2) 1) Permitted voltage range 2) Minimum/Full load at 230 V/Half load at 230 V 3) At full load and 230 V 4) Maximum 5) Maximum / At 360 µs 6) +1.0/-0.5 V 7) Partial load 0…80 W 8) SELV-equivalent June 8, 2016, 11:15:11 OT 80/220…240/24 P © 2016, OSRAM GmbH. All rights reserved. Page 2 of 5 Product datasheet Dimensions & weight __ Length 250.0 mm Width 50.0 mm Height 34.0 mm Mounting hole spacing, length 241.0 mm Product weight 850.00 g Cable cross-section, input side 1.0 mm² 1) Cable cross-section, output side 1.5 mm² 1) Wire preparation length, input side 10…11 mm Wire preparation length, output side 10…11 mm Cable/wire length, input side 300 mm Cable/wire length, output side 300 mm 1) Flexible Colors & materials Casing material Metal Temperatures & operating conditions Ambient temperature range -25…+55 °C Maximum temperature at tc test point 80 °C 1) Max.housing temperature in case of fault 100 °C Permitted rel. humidity during operation 5…85 % 1) Maximum at the Tc-point Lifespan ECG lifetime 1) At T case 50000 h 1) = 70°C at T point / 10% failure rate c Additional product data June 8, 2016, 11:15:11 OT 80/220…240/24 P © 2016, OSRAM GmbH. All rights reserved. Page 3 of 5 Product datasheet Encapsulated No Capabilities 1) Dimmable No Overheating protection Automatic reversible Overload protection Automatic reversible Short-circuit protection Automatic reversible No-load proof Yes Max. cable length to lamp/LED module 10 m Suitable for fixtures with prot. class II Type of connection, output side Push terminal 1) With OPTOTRONIC dimmers Certificates & standards __ Approval marks – approval CE / CB / C-Tick Standards Acc. to IEC 61347-1/Acc. to IEC 61347-2-13/Acc. to IEC 62384/Acc. to CISPR 15/Acc. to IEC 61000-32/Acc. to IEC 61000-3-3/Acc. to IEC 61547 Protection class II Type of protection IP67 Logistical data Temperature range at storage -40…85 °C Download Data File Brochures 24V OPTOTRONIC outdoor drivers (GB) Brochures Poster OPTOTRONIC LED drivers Certificates ENEC certificate OT 80 220-240 24 DIM P Declarations of conformity Declaration of conformity - OT 80220-24024 P - OT 120220-24024 P - OT 240 Installation/Operation notice Instruction Sheet OT 80220-24024 P Logistical Data June 8, 2016, 11:15:11 OT 80/220…240/24 P © 2016, OSRAM GmbH. All rights reserved. Page 4 of 5 Product datasheet Product code Product description Packaging unit (Pieces/Unit) Dimensions (length x width x height) Volume Gross weight 4008321981684 OT 80/220…240/24 P Shipping carton box 10 499 mm x 140 mm x 393 mm 27.45 dm³ 10650.00 g The mentioned product code describes the smallest quantity unit which can be ordered. One shipping unit can contain one or more single products. When placing an order, for the quantity please enter single or multiples of a shipping unit. Disclaimer Subject to change without notice. Errors and omission excepted. Always make sure to use the most recent release. __ June 8, 2016, 11:15:11 OT 80/220…240/24 P © 2016, OSRAM GmbH. All rights reserved. Page 5 of 5