IndustrialNet Category 6A RJ45 Field Terminable Plugs: PN591E

IndustrialNet Category 6A RJ45 Field Terminable Plugs
1
S/FTP
min. 50mm
U/FTP
SF/UTP
min. 100mm (min. 4 inch)
min. 50mm
(min. 2 inch)
(min. 2 inch)
50
Fold back braid.
Score and remove foil
Fold back braid and
remove all foils
U/UTP
min. 50mm
(min. 2 inch)
Trim pair separator
if applicable
T568B
(cable end 1)
(cable end 1)
5mm
(0.2 inch)
(0.2 inch)
Presort pairs. Remove pair screen
to 5mm (0.2 inch) max.
(min. 2 inch)
Trim pair separator
if applicable
Remove all foils
Note: for T568A,
green and orange
pairs will not match
the wire manager
T568A
5mm
min. 50mm
Presort pairs. Remove pair screen
to 5mm (0.2 inch) max.
(cable end 2)
(cable end 2)
Wrap drain wire
S/FTP, U/FTP and SF/UTP
Wire manager WHITE for Ø1.0 - 1.6 mm
(0.039 - 0.063 inch) CONDUCTOR INSULATION DIA.
15
3
2
Wire manager GREY for Ø0.85 - 1.0 mm
(0.033 - 0.039) inch
CONDUCTOR INSULATION DIA.
4
5
Cut all wires
protruding
0.5mm (0.02 inch) max.
5
Smooth wires before inserting into the wire manager
mm 0
6
Center Tool jaws on top and bottom
wire managers during crimping.
Press down evenly with parallel
jaw pliers (required tool, Knipex P.N.:
86 03 250)
untwist and insert pairs into the wire manager
7
8
Wire manager can be brought to end
position by means of screen cover
9
1
2
Remove assembly aid
Adjustable cable strain relief.
Color code
T568
2
approx.
18mm
(0.7 inch)
3
1
Insert the wire manager
Press down evenly with parallel
jaw pliers (required tool, Knipex P.N.:
86 03 250) to snap housing parts
together
Technical Support • Phone: 866-405-6654 • Email: [email protected] • www.panduit.com
4
RJ45
PIN No.
70
Part Number: ISPS688FA for Ø1.0 - 1.6 mm / 0.039 - 0.063 inch CONDUCTOR INSULATION DIA.
Part Number: ISPS688FAS for Ø0.85 - 1.0 mm / 0.033 - 0.039 inch CONDUCTOR INSULATION DIA.
A
B
W-G
W-O
G
O
2
W-O
W-G
3
1
BL
BL
4
W - BL
W - BL
5
O
G
6
W - BR
W - BR
7
BR
BR
8
PN591E