IndustrialNet Category 6A RJ45 Field Terminable Plugs 1 S/FTP min. 50mm U/FTP SF/UTP min. 100mm (min. 4 inch) min. 50mm (min. 2 inch) (min. 2 inch) 50 Fold back braid. Score and remove foil Fold back braid and remove all foils U/UTP min. 50mm (min. 2 inch) Trim pair separator if applicable T568B (cable end 1) (cable end 1) 5mm (0.2 inch) (0.2 inch) Presort pairs. Remove pair screen to 5mm (0.2 inch) max. (min. 2 inch) Trim pair separator if applicable Remove all foils Note: for T568A, green and orange pairs will not match the wire manager T568A 5mm min. 50mm Presort pairs. Remove pair screen to 5mm (0.2 inch) max. (cable end 2) (cable end 2) Wrap drain wire S/FTP, U/FTP and SF/UTP Wire manager WHITE for Ø1.0 - 1.6 mm (0.039 - 0.063 inch) CONDUCTOR INSULATION DIA. 15 3 2 Wire manager GREY for Ø0.85 - 1.0 mm (0.033 - 0.039) inch CONDUCTOR INSULATION DIA. 4 5 Cut all wires protruding 0.5mm (0.02 inch) max. 5 Smooth wires before inserting into the wire manager mm 0 6 Center Tool jaws on top and bottom wire managers during crimping. Press down evenly with parallel jaw pliers (required tool, Knipex P.N.: 86 03 250) untwist and insert pairs into the wire manager 7 8 Wire manager can be brought to end position by means of screen cover 9 1 2 Remove assembly aid Adjustable cable strain relief. Color code T568 2 approx. 18mm (0.7 inch) 3 1 Insert the wire manager Press down evenly with parallel jaw pliers (required tool, Knipex P.N.: 86 03 250) to snap housing parts together Technical Support • Phone: 866-405-6654 • Email: [email protected] • www.panduit.com 4 RJ45 PIN No. 70 Part Number: ISPS688FA for Ø1.0 - 1.6 mm / 0.039 - 0.063 inch CONDUCTOR INSULATION DIA. Part Number: ISPS688FAS for Ø0.85 - 1.0 mm / 0.033 - 0.039 inch CONDUCTOR INSULATION DIA. A B W-G W-O G O 2 W-O W-G 3 1 BL BL 4 W - BL W - BL 5 O G 6 W - BR W - BR 7 BR BR 8 PN591E