8W DC-DC Converter P8Z-Series ● ● ● ● ● ● ● 8W Output power 2:1 Wide input voltage range International safety standard approval Five-sided continuous shield High efficiency up to 85% Standard 1.25" x 0.8" x 0.4" package Fixed switching frequency Model selection guide Typ Input nominal Input current voltage full-load [VDC] [mA] Single Output P8Z12S33 9...18 724 P8Z12S05 9...18 801 P8Z12S12 9...18 833 P8Z12S15 9...18 843 P8Z24S33 18...36 362 P8Z24S05 18...36 396 P8Z24S12 18...36 416 P8Z24S15 18...36 416 P8Z48S33 36...75 181 P8Z48S05 36...75 198 P8Z48S12 36...75 208 P8Z48S15 36...75 208 Dual Output P8Z12D05 9...18 843 P8Z12D12 9...18 833 P8Z12D15 9...18 834 P8Z24D05 18...36 427 P8Z24D12 18...36 422 P8Z24D15 18...36 411 P8Z48D05 36...75 211 P8Z48D12 36...75 206 P8Z48D15 36...75 206 Output voltage [VDC] Output current [mA] Efficiency typ. [%] Capacitor load max. [uF] 3.3 5 12 15 3.3 5 12 15 3.3 5 12 15 2000 1500 666 533 2000 1500 666 533 2000 1500 666 533 80 82 84 83 80 83 84 84 80 83 84 84 3300 1600 350 240 3300 1600 350 240 3300 1600 350 240 ±5 ±12 ±15 ±5 ±12 ±15 ±5 ±12 ±15 ±800 ±333 ±267 ±800 ±333 ±267 ±800 ±333 ±267 83 84 84 82 83 85 83 85 85 2 x 1000 2 x 160 2 x 100 2 x 1000 2 x 160 2 x 100 2 x 1000 2 x 160 2 x 100 Page 1 of 2 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 8W DC-DC Converter P8Z-Series Specifications Input Voltage range Filter Isolation: Rated voltage Leakage current Resistance Capacitance Output Cross regulation (dual) Ripple and noise (at 20 MHz BW) Short ciruit protection Remote control input DC-DC ON DC-DC OFF Remote off input current General Specification Efficiency Switching frequency Environmental Operating temperatur (ambient) Storage temperature Max. case temperature Thermal impedance Humidity Physical Dimensions Weight Potting material Case material 9-18, 18-36, 36-75 VDC Pi type 1600 VDC 1 mA 109 Ω 300 pF, typ. ± 5% Single: 50mVp-p continuous automatic recovery Over load protection 150% @ nominal input Line voltage regulation ± 0,2% Load voltage regulation single: ± 0,5% dual: ±1% @ 10% to 100 % load Temperature coefficient ± 0.02% / °C Open or 3.5 V…12 V Short or 0 V…1.2 V 2.5 mA See table 300 kHz, typ. -40 °C to +85 °C with derating (see table) -55 °C to +105 °C 100°C 20 °C / Watt 5% to 95% RH 31.8x20.3x10.2 mm 16 g Epoxy (UL94-V0) Nickel-coated copper Dimensions 31.8 0.5 x 0.25 14 PHI-CON P8Z12S05 16 20.3 22 23 bottom view 11 0.5 9 15.2 3 2 1 2.54 10.2 3.8 Pin connections Pin Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 5.05 f 1 2 3 9 11 14 16 22 23 Standard Single Dual CTRL input CTRL input - Input - Input - Input - Input NC Common NC - Output + Output + Output - Output Common + Input + Input + Input + Input Page 2 of 2 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected]