8W DC-DC Converter P8Z-Series
●
●
●
●
●
●
●
8W Output power
2:1 Wide input voltage range
International safety standard approval
Five-sided continuous shield
High efficiency up to 85%
Standard 1.25" x 0.8" x 0.4" package
Fixed switching frequency
Model selection guide
Typ
Input nominal Input current
voltage
full-load
[VDC]
[mA]
Single Output
P8Z12S33
9...18
724
P8Z12S05
9...18
801
P8Z12S12
9...18
833
P8Z12S15
9...18
843
P8Z24S33
18...36
362
P8Z24S05
18...36
396
P8Z24S12
18...36
416
P8Z24S15
18...36
416
P8Z48S33
36...75
181
P8Z48S05
36...75
198
P8Z48S12
36...75
208
P8Z48S15
36...75
208
Dual Output
P8Z12D05
9...18
843
P8Z12D12
9...18
833
P8Z12D15
9...18
834
P8Z24D05
18...36
427
P8Z24D12
18...36
422
P8Z24D15
18...36
411
P8Z48D05
36...75
211
P8Z48D12
36...75
206
P8Z48D15
36...75
206
Output
voltage
[VDC]
Output
current
[mA]
Efficiency
typ.
[%]
Capacitor
load max.
[uF]
3.3
5
12
15
3.3
5
12
15
3.3
5
12
15
2000
1500
666
533
2000
1500
666
533
2000
1500
666
533
80
82
84
83
80
83
84
84
80
83
84
84
3300
1600
350
240
3300
1600
350
240
3300
1600
350
240
±5
±12
±15
±5
±12
±15
±5
±12
±15
±800
±333
±267
±800
±333
±267
±800
±333
±267
83
84
84
82
83
85
83
85
85
2 x 1000
2 x 160
2 x 100
2 x 1000
2 x 160
2 x 100
2 x 1000
2 x 160
2 x 100
Page 1 of 2
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
8W DC-DC Converter P8Z-Series
Specifications
Input
Voltage range
Filter
Isolation:
Rated voltage
Leakage current
Resistance
Capacitance
Output
Cross regulation (dual)
Ripple and noise
(at 20 MHz BW)
Short ciruit protection
Remote control input
DC-DC ON
DC-DC OFF
Remote off input
current
General Specification
Efficiency
Switching frequency
Environmental
Operating temperatur
(ambient)
Storage temperature
Max. case temperature
Thermal impedance
Humidity
Physical
Dimensions
Weight
Potting material
Case material
9-18, 18-36, 36-75 VDC
Pi type
1600 VDC
1 mA
109 Ω
300 pF, typ.
± 5%
Single: 50mVp-p
continuous
automatic recovery
Over load protection
150% @ nominal input
Line voltage regulation ± 0,2%
Load voltage regulation single: ± 0,5%
dual: ±1%
@ 10% to 100 % load
Temperature coefficient ± 0.02% / °C
Open or 3.5 V…12 V
Short or 0 V…1.2 V
2.5 mA
See table
300 kHz, typ.
-40 °C to +85 °C with
derating (see table)
-55 °C to +105 °C
100°C
20 °C / Watt
5% to 95% RH
31.8x20.3x10.2 mm
16 g
Epoxy (UL94-V0)
Nickel-coated copper
Dimensions
31.8
0.5 x 0.25
14
PHI-CON
P8Z12S05
16
20.3
22 23
bottom view
11
0.5
9
15.2
3 2 1
2.54
10.2
3.8
Pin connections
Pin
Life Support Policy: HY-LINE does not authorize the use of
any of its products for use in life support devices or
systems without the express written approval of an officer
of the Company. Life support systems are devices which
support or sustain life, and whose failure to perform, when
properly used in accordance with instructions for use
provided in the labeling, can be reasonably expected to
result in significant injury to the user. Rev: 5.05 f
1
2
3
9
11
14
16
22
23
Standard
Single
Dual
CTRL input
CTRL input
- Input
- Input
- Input
- Input
NC
Common
NC
- Output
+ Output
+ Output
- Output
Common
+ Input
+ Input
+ Input
+ Input
Page 2 of 2
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]