30W DC-DC Converter P30D-Series ● ● ● ● ● ● ● ● ● ● 4:1 wide input voltage range High efficiency up to 91% Over current protection Over voltage protection Over temperature protection Continuous short circuit protection Adjustable output voltage On/Off - remote control input Soft start Standard 2" x 1" x 0.4" package Model selection guide Typ Single output P30D243R3S P30D2405S P30D2405R1S P30D2412S P30D2415S P30D483R3S P30D4805S P30D4805R1S P30D4812S P30D4815S Dual output P30D2405D P30D2412D P30D2415D P30D4805D P30D4812D P30D4815D Triple output P30D243R3S12D P30D243R3S15D P30D2405S12D P30D2405S15D P30D483R3S12D P30D483R3S15D P30D4805S12D P30D4805S15D Input voltage range [VDC Input current nofullload load [mA] [mA] 9...36 9...36 9...36 9...36 9...36 18...75 18...75 18...75 18...75 18...75 60 100 90 30 30 50 60 60 30 30 9...36 9...36 9...36 18...75 18...75 18...75 9...36 9...36 9...36 9...36 18...75 18...75 18...75 18...75 Output voltage [VDC] Output current range [A] Cap. load max. [µF] Output auxiliary 1185 1420 1448 1436 1420 593 703 724 718 710 3.3 5 5.1 12 15 3.3 5 5.1 12 15 0…7.5 0…6.0 0…6.0 0…2.5 0…2.0 0…7.5 0…6.0 0…6.0 0…2.5 0…2.0 20000 14000 14000 2000 2000 20000 14000 14000 2000 2000 89 91 91 90 91 89 91 91 90 90 120 30 40 70 30 40 1437 1453 1437 710 718 718 ±5 ±12 ±15 ±5 ±12 ±15 0..±3.00 0..±1.25 0..±1.00 0..±3.00 0..±1.25 0..±1.00 2 x 3000 2 x 1300 2 x 1300 2 x 3000 2 x 1300 2 x 1300 90 89 89 91 90 90 80 90 100 110 50 50 60 60 1287 1279 1440 1430 636 640 712 707 3.3 3.3 5 5 3.3 3.3 5 5 0.5...5 0.5...5 0.4...4 0.4...4 0.5...5 0.5...5 0.4...4 0.4...4 15000 15000 8000 8000 15000 15000 8000 8000 [VDC] ±12 ±15 ±12 ±15 ±12 ±15 ±12 ±15 Output current range [mA] ±42..420 ±33..330 ±42..420 ±33..330 ±42..420 ±33..330 ±42..420 ±33..330 Cap. load max. [µF 2x 2x 2x 2x 2x 2x 2x 2x Efficiency typ. 220 220 220 220 220 220 220 220 [%] 89 89 89 90 89 89 91 90 Circuit diagram + INPUT 220 µF < 90 mΩ L 12 µH 33 µF <1Ω 1 Remote ON 3 Remote OFF 2 - INPUT 4 + OUTPUT R - Trim down DC/DC - Converter 6 1 µF max. CL see table P30DxxxxS 5 R - Trim up - OUTPUT 470 pF, 2 kV, 1206 Page 1 of 3 Deutschland: Inselkammerstrasse 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 30W DC-DC Converter P30D-Series Specifications Input Input Filter: Under voltage lockout Input surge voltage 100 ms max. Start up time Quiescent current @ remote "off" Remote control threshold Output Over voltage protection with Z-diode clamp Voltage accuracy Voltage adjustability Ripple and noise (at 20 MHz BW) Short circuit protection Line voltage regulation Load voltage regulation Cross regulation @ dual, triple Temperature coefficient Transient response recovery time Transien response deviation Over load protection Pi- type 24V Type: on @ 8.6V, off @ 7.9V 48V Type: on @ 17.8V, off @ 16V 24 V input : -0.7…50 VDC 48 V input : -0.7…100 VDC 30ms typ. @ R-load 5mA @ nominal Vin Off-state: 0…1.2V, On-state: 3…12V 3.3V-output-type 3.9V (±)5V, 5.1V-outp 6.2V (± 6.2V) (±)12V-output-type 15V (±15V) (±)15V-output-type 18V (±18V) Single, dual: ±1%, auxiliary: ± 5% ±10% (only for single output) Single, dual: 100mVp-p Triple: main 50mVp-p, aux 75mVp-p Hiccup, automatics recovery Single, dual: ± 0.5% Triple: main ± 1%, auxiliary: ± 5% single: ±0.5% @ 0…100% load dual: ±1%, max. @ blanced load auxiliary: ± 5% @ 0…100% load ±5% ± 0.02% / °C 250µs 3 % @ 25% load changes 150% typ. of full load Isolation Isolation voltage Resistance Capacitance General Switching frequency Standard in accordance with Radiated emissions Conducted emissions with ext. filter ESD Radiated immunity Fast transient Surge Conducted immunity PFMF MTBF (MIL-HDBK-217) Environmental Operating temperature Storage temperature Maximum case temp. Over temp. protection Humidity Physical Dimensions Weight Case material Potting material Soldering temperature Input to output 1600 VDC, 3sec. 9 10 Ω, min 1500 pF, max 330 kHz, typ. IEC 60950-1 EN60950-1 EN55022 level A EN55022 level A EN61000-4-2 pref. criteria A EN61000-4-3 pref. criteria A EN61000-4-4 pref. criteria A EN61000-4-5 pref. criteria A EN61000-4-6 pref. criteria A EN61000-4-8 pref. criteria A Single, dual: >435 khrs Triple: >320 khrs -40°C to +75°C (with derating 50%) -40 °C to +125 °C +105 °C +115 °C, typ. on case 95% rel. Humidity 50.8 x 25.4 x 10.2 mm 31 g Nickel-coated copper Epoxy ( UL94-V0) 260°C, 10s, 1.5mm from case Efficiency vs output load Page 2 of 3 Deutschland: Inselkammerstrasse 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 30W DC-DC Converter P30D-Series Dimensions Pin connections Pin 1 2 3 4 5 6 7 Single +Vin -Vin Remote Contr. + Vout - Vout Trim No pin Dual +Vin -Vin Remote Contr. + Vout Common - Vout No pin Triple +Vin -Vin Remote Contr. + Aux - Aux Common + Vout Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 01/12 f Page 3 of 3 Deutschland: Inselkammerstrasse 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected]