Click Here to download this file: /data/power/oky2-t60-w12.pdf

OKY2-T/60-W12 Series
Programmable Output 60-Amp SMT PoL
PRODUCT OVERVIEW
Typical unit
FEATURES
 4.5-14Vdc input voltage range
 Programmable output voltage from 0.7-2.0Vdc
 Up to 60 Amps of output current
 Drives 20,000μF tantalum capacitive loads
 Industry Standard surface mount package
 1.3 x 0.9 x 0.38 inches (33.0 x 22.9 x 9.6 mm)
 High efficiency of 87.5%, (typical)
 Outstanding thermal derating performance
 Over temperature and over current protection
 Over voltage and under voltage protection
 On/Off control (Positive or Negative logic)
 Power Good signal
 Sequence/Tracking function
 Parallel operation up to 3 modules
 Optional SYNC/CLKOUT function
 RoHS-6 hazardous substance compliance
The OKY2-T/60-W12 series are
miniature non-isolated Point-of-Load (PoL)
DC-DC power converters for embedded
applications. The tiny form factor measures
only 1.3 x 0.9 x 0.38 inches (33.0 x 22.9 x
9.6 mm). Applications include powering
CPU’s, datacom/telecom systems,
Distributed Bus Architectures (DBA),
programmable logic and mixed voltage
systems.
The converters have a wide input voltage
range of 4.5 to 14Vdc and a maximum
output current of 60 Amps. Based on a fixed
frequency synchronous buck converter
switching topology, this high power
conversion efficient PoL module features
programmable output voltage, On/Off control,
Power Good signal, sequence/tracking,
parallel operation and optional SYNC/CLKOUT
function.
These converters also include under
voltage lock out (UVLO), output short circuit
protection, over-current, over-temperature,
over-voltage and under-voltage protection.
These units are designed to meet all
standard UL/EN/IEC 60950-1 safety and FCC
EMI/RFI emissions certifications and RoHS-6
hazardous substance compliance.
+Vin
+Vout
• Switching
F1
On/Off
Control
External
DC
Power
Source
Open=On
Closed=Off
(Positive On/Off)
• Filters
+Sense
• Current Sense
-Sense
Controller
-Trim
Reference and
Error Amplifier
+Trim
Common
CLKOUT
Sequence/ Tracking
SYNC
Power Good
Figure 1. Connection Diagram
Typical topology is shown. Murata Power Solutions recommends an external fuse.
www.murata-ps.com/support
MDC_OKY2-T/60-W12.A01 Page 1 of 15
OKY2-T/60-W12 Series
Programmable Output 60-Amp SMT PoL
PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE 


Output
Model Number
Vout
Iout
Power R/N (mVp-p) Regulation (max.)
(Vdc)
(Amps,max)
(Watts)
Max.
Line (%) Load (%)
Input
Vin nom
(Vdc)
Range
(Vdc)
Iin, no load Iin, full load
(Amps)
(mA)
Efficiency
(%)
On/Off
SYNC
Logic
OKY2-T/60-W12PA-C
0.7-2.0
60
120
50
±0.25
±0.25
12
4.5-14
160
11.6
87.5
Pos.
Yes
OKY2-T/60-W12P-C
0.7-2.0
60
120
50
±0.25
±0.25
12
4.5-14
160
11.6
87.5
Pos.
No
OKY2-T/60-W12NA-C
0.7-2.0
60
120
50
±0.25
±0.25
12
4.5-14
160
11.6
87.5
Neg.
Yes
OKY2-T/60-W12N-C
0.7-2.0
60
120
50
±0.25
±0.25
12
4.5-14
160
11.6
87.5
Neg.
No
1.
2.
Please refer to the Part Number Structure for additional ordering information and options.
All specifications are at nominal line voltage, Vout=nominal (2.0V) and full load, +25°C unless
otherwise noted. Output capacitors are 100 uF*1 ceramic and 470uF*10 tantalum (Panasonic
3.
Package
inches (mm)
1.30x0.9x0.38
(33.0x22.9x9.6)
1.30x0.9x0.38
(33.0x22.9x9.6)
1.30x0.9x0.38
(33.0x22.9x9.6)
1.30x0.9x0.38
(33.0x22.9x9.6)
POSCAP). Input cap is 22 uF*3 ceramic and 560uF*1 electrolytic (Panasonic OS- CON). See
detailed specifications. I/O caps are necessary for our test equipment.
Use adequate ground plane and copper thickness adjacent to the converter.
PART NUMBER STRUCTURE
OKY2 - T / 60 - W12 N A - C
RoHS Hazardous Materials compliance
C = RoHS-6 (does not claim EU RoHS exemption 7b–lead in solder)
Okami Series
Non-isolated PoL
Y = Surface mount package
2 = Sequence/Tracking
A = SYNC/CLKOUT (optional)
T = Trimmable Output
Voltage Range: (0.7-2.0Vdc)
On/Off Control Logic
N = Negative
P = Positive
Maximum Rated Output
Current in Amps
Input Voltage Range:
W12 = 4.5-14Vdc (12Vdc nominal)
Product Marking
Because of the small size of these products, the product marking
contains a character-reduced code to indicate the model number and
manufacturing date code. Not all items on the marking are always
used. Please note that the marking differs from the product
photograph. Here is the layout of the Marking.
Codes
Layout
①
②③
④⑤⑥⑦
①
Product Code
Y21160
Y21160
Y20160
Y20160
Rev Code
2
1
2
1
The manufacturing date code is four characters:
Rev code
②③④⑤⑥⑦
Model Number
OKY2-T/60-W12PA-C
OKY2-T/60-W12P-C
OKY2-T/60-W12NA-C
OKY2-T/60-W12N-C
Product code
⑧⑨⑩⑪ Manufacturing date code
⑧⑨⑩⑪
The marking contains three rows of information:
First character - Manufacturing information
Second character - Last digit of manufacturing year, example 2011
Third character - Month code (1 through 9 and O through D)
Fourth character - Day code (1 through 9 = 1 to 9, 10=O and
11 through 31 = A through Z)
First and second row – Rev code and product code
Third row - Manufacturing date code
www.murata-ps.com/support
MDC_OKY2-T/60-W12.A01 Page 2 of 15
OKY2-T/60-W12 Series
Programmable Output 60-Amp SMT PoL
FUNCTIONAL SPECIFICATIONS
ABSOLUTE MAXIMUM RATINGS
Conditions
Input Voltage, Continuous
ON/OFF Pin
SEQ Pin
SYNC Pin
SHARE/PGOOD/CLKOUT/±Trim Pins
Minimum
Typical/Nominal
Maximum
Units
Vdc
Power on, referred to -Vin
Vdc
Power on, referred to -Vin
V
Power on, referred to -Vin
V
Power on, referred to -Vin
Source ONLY
Current-limited, no damage, short-circuit
Output Current
0
60
A
protected
Storage Temperature Range
Vin = Zero (no power)
-55
125
°C
Absolute maximums are stress ratings. Exposure of devices to greater than any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those
listed in the Performance/Functional Specifications Table is not implied or recommended.
INPUT
Operating Voltage Range
Start-up threshold
Undervoltage shutdown
Overvoltage shutdown
Internal Filter Type
Input current
Full Load Conditions
Low Line
No Load Current
Shut-Down Mode Input Current
Tracking/Sequencing
Operating Voltage Range
Slew Rate (Power-Up)
Slew Rate (Power-Down)
Tracking accuracy, rising input
Tracking accuracy, falling input
-0.3
-0.3
-0.3
-0.3
14
14
3
6
Conditions
4.5
Rising input voltage
Note 15
Vin = nominal
Vin = minimum
Iout = minimum, unit = ON
12
4.3
4.0
Vo*120%
Capacitive
14
11.6
30
160
1
Vdc
Vdc
Vdc
Vdc
A
A
mA
mA
3
2
1
V
V/ms
V/ms
Vout = ±100mV of Sequence In (TYP)
Vout = ±200mV of Sequence In (TYP)
GENERAL and SAFETY
Efficiency
Safety
Calculated MTBF (Note 4a)
Calculated MTBF (Note 4b)
Vin =5V, Vout = 2V, full load
Vin=5V,Vout=2V,Io=50A
Certified to UL-60950-1, CSA-C22.2 No. 60950-1,
IEC/EN60950-1, 2nd edition(pending)
Per Telcordia SR-332 Issue 2, Method 1, Class 3,
Ground Benign, Tambient =+25°C
Per Telcordia SR-332 Issue 3, Method 1, Class 3,
Ground Benign, Tambient =+25°C
87.5
90
%
322,334
Hours
1,643,147
Hours
310
4.5
4.5
kHz
mS
mS
DYNAMIC CHARACTERISTICS
Fixed Switching Frequency
Startup Time
Startup Time
Dynamic Load Response
Dynamic Load Peak Deviation
Vout=nominal (Vin On to 90% of Vo)
Vout=nominal (Remote On to 90% of Vo)
2.5
(25-75% load step, di/dt)
same as above
±3.0%
A/μSec
Voset
FEATURES
Remote On/Off Control (Note 5)
“N” suffix:
Negative Logic, ON state
ON = Open pin or -0.3V to +0.6V. max.
Negative Logic, OFF state
OFF = +3.0Vmin. to +Vin max.
Control Current
Open collector/drain
“P” suffix:
Positive Logic, ON state
ON = +3.0Vmin. to +Vin max.
Positive Logic, OFF state
OFF =Open or -0.3V to +0.6V.max.
Control Current
Open collector/drain
Power-Good Output (Pulled up to 5.4Vreg(TYP) internally)
PGood TRUE (HI)
PGood FALSE (LO)
-0.3
3.0
0.6
Vin max
3.3
Vdc
Vdc
mA
3.0
-0.3
Vin max
0.6
3.3
V
V
mA
1.0
Vin max or to 5.8
V
V
kHz
(Vset –13%) < Vout < (Vset +13%)
Out of above range
OPTIONS (OKY2-T/60-W12NA-C & OKY2-T/60-W12PA-C only)
SYNC
Input Voltage Range
Input Frequency Range
Input Wave Form(Note 18)
CLKOUT
Output voltage range
Waveform
Duty cycle
Signal Low
Signal High
-0.3
3.0
280 to 340
Square Plus Waveform (Duty cycle 20-80%)
-0.3
Vin max or to 5.8
Square Plus Waveform
50
V
%
www.murata-ps.com/support
MDC_OKY2-T/60-W12.A01 Page 3 of 15
OKY2-T/60-W12 Series
Programmable Output 60-Amp SMT PoL
FUNCTIONAL SPECIFICATIONS (CONT.)
OUTPUT
Total Output Power
Voltage
Output Voltage Range
Minimum Loading
Accuracy (50% load, untrimmed)
Overvoltage Protection
Undervoltage Protection
Current
Output Current Range
Current Limit Inception
Short Circuit
Short Circuit Duration
(remove short for recovery)
Short circuit protection method
See Derating
0
Note 13
0.7
Ripple and Noise (20MHz bandwidth)
Maximum Capacitive Loading (Note 14)
Parallel and SYNC operation
Maximum parallel units (with SYNC)
Maximum parallel units (w/o SYNC)
Load Share Accuracy
External input frequency range (Note 18)
W
2
Vdc
None
±2.0% of Vnominal
>113%Vset(Hiccup),>120%Vset(Latch)
<87%Vset(Hiccup)
Note 16
0
98% of Vnom., after warmup
Vdc
Vdc
Vdc
60
100
Output shorted to ground, no damage
A
A
Continuous
Current limiting
Prebias Start-up
Regulation
Line Regulation
120
Converter will start up if the external output voltage is less than Vnominal.
Vin = min. to max.,Vout = nom., Iout = nom.
±0.25
% of Vout
50
mV pk-pk
Note 8
4800
Cap-ESR>0.01 Ohms
20000
μF
3
2
90
Io=Iomax
280
340
Units
Units
%
kHz
MECHANICAL
Outline Dimensions
(Please refer to outline drawing)
Weight
LxWxH
1.30x0.9x0.38
33.0x22.9x9.6
0.39
11.5
Inches
mm
Ounces
Grams
ENVIRONMENTAL
Operating Ambient Temperature Range
Storage Temperature
Thermal Protection/Shutdown
Relative Humidity
RoHS rating
With Derating (Note 9)
Vin = Zero (no power)
Measured in center
85
125
-40
-55
135
To 85%/+85°C, non-condensing
RoHS-6
°C
°C
°C
Specification Notes
(1)
Specifications are typical at +25°C, Vin=nominal (+12V.), Vout=nominal (+2V), full load,
external caps and natural convection unless otherwise indicated. Extended tests at full power
must supply substantial forced airflow. All models are tested and specified with external 100
uF*1 ceramic and 470uF*10 tantalum output capacitors and a 22 uF*3 ceramic and 560uF*1
electrolytic external input capacitor. All capacitors are low ESR types. These capacitors are
necessary to accommodate our test equipment and may not be required to achieve specified
performance in your applications. However, Murata recommends installation of these
capacitors. All models are stable and regulate within spec under no-load conditions.
(2) Input Back Ripple Current is tested and specified over a 5 Hz to 20 MHz bandwidth. Input
filtering is Cin=2 x 100 uF ceramic, Cbus=1000 uF electrolytic, Lbus=1 uH.
(3) Note that Maximum Power Derating curves indicate an average current at nominal input
voltage. At higher temperatures and/or lower airflow, the DC/DC converter will tolerate brief
full current outputs if the total RMS current over time does not exceed the Derating curve.
(4a) Mean Time Before Failure is calculated using the Telcordia (Belcore) Issue 2, Method 1, Case
3, Ground Benign conditions, Tpcboard = +25°C, full output load, natural air convection.
(4b) Mean Time Before Failure is calculated using the Telcordia (Belcore) Issue 3, Method 1, Case
3, Ground Benign conditions, Tpcboard = +25°C, full output load, natural air convection.
(5) The On/Off Control Input should use either a switch or an open collector/open drain transistor
referenced to Input Common. A logic gate may also be used by applying appropriate external
voltages which do not exceed +Vin
(6) Short circuit shutdown begins when the output voltage degrades approximately 2% from the
selected setting.
(7) “Hiccup” overcurrent operation repeatedly attempts to restart the converter with a brief, fullcurrent output. If the overcurrent condition still exists, the restart current will be removed and
then tried again. This short current pulse prevents overheating and damaging the converter.
Once the fault is removed, the converter immediately recovers normal operation.
(8)
(9)
(10)
(11)
(12)
(13)
(14)
(15)
(16)
(17)
(18)
Output noise may be further reduced by adding an external filter. At zero output current, the
output may contain low frequency components which exceed the ripple specification. The output
may be operated indefinitely with no load.
All models are fully operational and meet published specifications, including “cold start” at 40°C.
Regulation specifications describe the deviation as the line input voltage or output load current is
varied from a nominal midpoint value to either extreme.
Other input or output voltage ranges will be reviewed under scheduled quantity special order.
Maximum PC board temperature is measured with the sensor in the center of the converter.
Do not exceed maximum power specifications when adjusting the output trim.
The maximum output capacitive loads depend on the Equivalent Series Resistance (ESR) of the
external output capacitor and, to a lesser extent, the distance and series impedance to the load.
Larger caps will reduce output noise but may change the transient response. Newer ceramic
caps with very low ESR may require lower capacitor values to avoid instability. Thoroughly test
your capacitors in the application. Please refer to the Output Capacitive Load Application Note.
Do not allow the input voltage to degrade lower than the input under voltage shutdown voltage at
all times. Otherwise, you risk having the converter turn off. The under voltage shutdown is not
latching and will attempt to recover when the input is brought back into normal operating range.
The outputs are not intended to sink appreciable reverse current.
“Hiccup” over current operation repeatedly attempts to restart the converter with a brief, fullcurrent output If the over current condition still exists the restart current will be removed and
then try again. This short current pulse prevents overheating and damaging the converter. Once
the fault is removed, the converter immediately recovers normal operation.
The switching frequency will lock to an external frequency (square pulse waveform), typically the
CLKOUT signal from another converter or external clock. The internal oscillator synchronizes
with the leading edge of the input signal.
www.murata-ps.com/support
MDC_OKY2-T/60-W12.A01 Page 4 of 15
OKY2-T/60-W12 Series
Programmable Output 60-Amp SMT PoL
PERFORMANCE DATA AND OSCILLOGRAMS
Efficiency vs. Line Voltage and Load Current @ +25°C. (Vout = 0.7V)
Maximum Current Temperature Derating at Sea Level (Vin=12V, Vout=0.7V)
70
100
60
Output current [A]
95
Efficiency [%]
90
85
80
Vin=4.5V
Vin=12V
Vin=14V
75
70
65
0
10
20
30
40
50
60
Load Current [Amps]
50
0.2m/s(40LFM)
40
0.5m/s(100LFM)
30
1m/s(200LFM)
1.5m/s(300LFM)
20
2m/s(400LFM)
10
0
25
35
45
55
65
Ta [degC]
75
85
95
On/Off Enable Delay (Vin=12V, Vout=0.7V, Iout=60A, Cload=4800uF)
Trace1=Enable, Trace2=Vout
Output Ripple and Noise
(Vin=12V, Vout=0.7V, Iout=60A, Cload=4800uF, ScopeBW=20MHz)
Step Load Transient Response (Vin=12V, Vout=0.7V, Cload=4800uF,
Iout=15A to 45A) Trace 2=Vout, 50 mV/div, Trace 4=Iout, 20A/div.
Step Load Transient Response (Vin=12V, Vout=0.7V, Cload=4800uF,
Iout=45A to 15A) Trace 2=Vout, 50 mV/div, Trace 4=Iout, 20A/div.
www.murata-ps.com/support
MDC_OKY2-T/60-W12.A01 Page 5 of 15
OKY2-T/60-W12 Series
Programmable Output 60-Amp SMT PoL
PERFORMANCE DATA AND OSCILLOGRAMS
Efficiency vs. Line Voltage and Load Current @ +25°C. (Vout = 1.2V)
Maximum Current Temperature Derating at Sea Level (Vin=12V, Vout=1.2V)
70
100
60
Output current [A]
95
Efficiency [%]
90
85
80
Vin=4.5V
Vin=12V
Vin=14V
75
70
65
0
10
20
30
40
50
60
Load Current [Amps]
50
0.2m/s(40LFM)
40
0.5m/s(100LFM)
30
1m/s(200LFM)
1.5m/s(300LFM)
20
2m/s(400LFM)
10
0
25
35
45
55
65
Ta [degC]
75
85
95
On/Off Enable Delay (Vin=12V, Vout=1.2V, Iout=60A, Cload=4800uF)
Trace1=Enable, Trace2=Vout
Output Ripple and Noise
(Vin=12V, Vout=1.2V, Iout=60A, Cload=4800uF, ScopeBW=20MHz)
Step Load Transient Response (Vin=12V, Vout=1.2V, Cload=4800uF,
Iout=15A to 45A) Trace 2=Vout, 50 mV/div, Trace 4=Iout, 20A/div.
Step Load Transient Response (Vin=12V, Vout=1.2V, Cload=4800uF,
Iout=45A to 15A) Trace 2=Vout, 50 mV/div, Trace 4=Iout, 20A/div.
www.murata-ps.com/support
MDC_OKY2-T/60-W12.A01 Page 6 of 15
OKY2-T/60-W12 Series
Programmable Output 60-Amp SMT PoL
PERFORMANCE DATA AND OSCILLOGRAMS
Efficiency vs. Line Voltage and Load Current @ +25°C. (Vout = 2.0V)
Maximum Current Temperature Derating at Sea Level (Vin=12V, Vout=2.0V)
70
100
60
Output current [A]
95
Efficiency [%]
90
85
Vin=4.5V
Vin=12V
Vin=14V
80
75
50
0.2m/s(40LFM)
40
0.5m/s(100LFM)
30
1m/s(200LFM)
1.5m/s(300LFM)
20
2m/s(400LFM)
70
10
65
0
10
20
30
40
50
60
0
Load Current [Amps]
25
35
45
55
65
Ta [degC]
75
85
95
On/Off Enable Delay (Vin=12V, Vout=2.0V, Iout=60A, Cload=4800uF)
Trace1=Enable, Trace2=Vout
Output Ripple and Noise
(Vin=12V, Vout=2.0V, Iout=60A, Cload=4800uF, ScopeBW=20MHz)
Step Load Transient Response (Vin=12V, Vout=2.0V, Cload=4800uF,
Iout=15A to 45A) Trace 2=Vout, 50 mV/div, Trace 4=Iout, 20A/div.
Step Load Transient Response (Vin=12V, Vout=2.0V, Cload=4800uF,
Iout=45A to 15A) Trace 2=Vout, 50 mV/div, Trace 4=Iout, 20A/div.
www.murata-ps.com/support
MDC_OKY2-T/60-W12.A01 Page 7 of 15
OKY2-T/60-W12 Series
Programmable Output 60-Amp SMT PoL
MECHANICAL SPECIFICATIONS
INPUT/OUTPUT CONNECTIONS
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Function
Vin
GND
Vout
Vout
GND
Vin
SEQ
PGOOD
ON/OFF
VSVS+
+Trim
-Trim
SHARE
CLKOUT*
SYNC*
* CLKOUT and SYNC pins are optional
(include A suffix). Please see the Part
Number Structure on Page 2.
Dimensions are in mm (inches) shown for ref. only.
Tolerances (unless otherwise specified):
.XX ± 0.02 (0.5)
.XXX ± 0.010 (0.25)
Angles ± 2˚
www.murata-ps.com/support
MDC_OKY2-T/60-W12.A01 Page 8 of 15
OKY2-T/60-W12 Series
Programmable Output 60-Amp SMT PoL
TAPE AND REEL INFORMATION
www.murata-ps.com/support
MDC_OKY2-T/60-W12.A01 Page 9 of 15
OKY2-T/60-W12 Series
Programmable Output 60-Amp SMT PoL
TAPE SPECIFICATIONS
Dimensions are in mm (inches) shown for ref. only.
Tolerances (unless otherwise specified):
.XX ± 0.02 (0.5)
.XXX ± 0.010 (0.25)
Angles ± 2˚
www.murata-ps.com/support
MDC_OKY2-T/60-W12.A01 Page 10 of 15
OKY2-T/60-W12 Series
Programmable Output 60-Amp SMT PoL
TECHNICAL NOTES
Input Fusing
Certain applications and/or safety agencies may require fuses at the inputs
of power conversion components. Fuses should also be used when there is
the possibility of sustained input voltage reversal which is not current
limited. For greatest safety, we recommend a fast blow fuse installed in
the ungrounded input supply line.
The installer must observe all relevant safety standards and regulations.
For safety agency approvals, install the converter in compliance with the
end-user safety standard.
Input Under-Voltage Shutdown and Start-Up Threshold
Under normal start-up conditions, converters will not begin to regulate
properly until the ramping-up input voltage exceeds and remains at the
Start-Up Threshold Voltage (see Specifications). Once operating,
converters will not turn off until the input voltage drops below the UnderVoltage Shutdown Limit. Subsequent restart will not occur until the input
voltage rises again above the Start-Up Threshold. This built-in hysteresis
prevents any unstable on/off operation at a single input voltage.
Users should be aware however of input sources near the Under-Voltage
Shutdown whose voltage decays as input current is consumed (such as
capacitor inputs), the converter shuts off and then restarts as the external
capacitor recharges. Such situations could oscillate. To prevent this, make
sure the operating input voltage is well above the UV Shutdown voltage AT
ALL TIMES.
Start-Up Time
Assuming that the output current is set at the rated maximum, the Vin to
Vout Start-Up Time (see Specifications) is the time interval between the
point when the ramping input voltage crosses the Start-Up Threshold and
the fully loaded regulated output voltage enters and remains within its
specified accuracy band. Actual measured times will vary with input
source impedance, external input capacitance, input voltage slew rate and
final value of the input voltage as it appears at the converter.
These converters include a soft start circuit to moderate the duty cycle of
its PWM controller at power up, thereby limiting the input inrush current.
The On/Off Remote Control interval from On command to Vout regulated
assumes that the converter already has its input voltage stabilized above
the Start-Up Threshold before the On command. The interval is measured
from the On command until the output enters and remains within its
specified accuracy band. The specification assumes that the output is fully
loaded at maximum rated current. Similar conditions apply to the On to
Vout regulated specification such as external load capacitance and soft
start circuitry.
Recommended Input Filtering
The user must assure that the input source has low AC impedance to
provide dynamic stability and that the input supply has little or no inductive
content, including long distributed wiring to a remote power supply. The
converter will operate with no additional external capacitance if these
conditions are met.
For best performance, we recommend installing a low-ESR capacitor
immediately adjacent to the converter’s input terminals. The capacitor
should be a ceramic type such as the Murata GRM32 series and a
electrolytic type such as Panasonic OS-CON series. Initial suggested
capacitor values are 22 uF*3 ceramic type and 560uF*1 electrolytic type,
rated at twice the expected maximum input voltage. Make sure that the
input terminals do not go below the under voltage shutdown voltage at all
times. More input bulk capacitance may be added in parallel (either
electrolytic or tantalum) if needed.
Recommended Output Filtering
The converter will achieve its rated output ripple and noise with additional
external capacitor. The user may install more external output capacitance
to reduce the ripple even further or for improved dynamic response. Again,
use low-ESR ceramic (Murata GRM32 series) and tantalum capacitors
such as Panasonic POSCAP. Initial values of 100 uF*1 ceramic type and
470uF*10 tantalum type may be tried, either single or multiple capacitors
in parallel. Mount these close to the converter. Measure the output ripple
under your load conditions.
Use only as much capacitance as required to achieve your ripple and noise
objectives. Excessive capacitance can make step load recovery sluggish or
possibly introduce instability. Do not exceed the maximum rated output
capacitance listed in the specifications.
Input Ripple Current and Output Noise
All models in this converter series are tested and specified for input
reflected ripple current and output noise using designated external
input/output components, circuits and layout as shown in the figures
below.
In the figure below, the two copper strips simulate real-world printed
circuit impedances between the power supply and its load. In order to
minimize circuit errors and standardize tests between units, scope
measurements should be made using BNC connectors or the probe ground
should not exceed one half inch and soldered directly to the test circuit.
Measuring Output Ripple and Noise (PARD)
Minimum Output Loading Requirements
All models regulate within specification and are stable under no load to full
load conditions. Operation under no load might however slightly increase
output ripple and noise.
Thermal Shutdown
To prevent many over temperature problems and damage, these
converters include thermal shutdown circuitry. If environmental conditions
cause the temperature of the DC/DC’s to rise above the Operating
Temperature Range
up to the shutdown temperature, an on-board electronic temperature
sensor will power down the unit. When the temperature decreases below
the turn-on threshold, the converter will automatically restart.
CAUTION: If you operate too close to the thermal limits, the converter may
shut down suddenly without warning. Be sure to thoroughly you’re your
application to avoid unplanned thermal shutdown.
www.murata-ps.com/support
MDC_OKY2-T/60-W12.A01 Page 11 of 15
OKY2-T/60-W12 Series
Programmable Output 60-Amp SMT PoL
Temperature Derating Curves
The graphs in this data sheet illustrate typical operation under a variety of
conditions. The derating curves show the maximum continuous ambient
air temperature and decreasing maximum output current which is
acceptable under increasing forced airflow measured in Linear Feet per
Minute (“LFM”). Note that these are AVERAGE measurements. The
converter will accept brief increases in current or reduced airflow as long
as the average is not exceeded.
Note that the temperatures are of the ambient airflow, not the converter
itself which is obviously running at higher temperature than the outside air.
Also note that very low flow rates (below about 25 LFM) are similar to
“natural convection,” that is, not using fan-forced airflow. Murata makes
Characterization measurements in a closed cycle wind tunnel with
calibrated airflow. We use both thermocouples and an infrared camera
system to observe thermal performance.
CAUTION: These graphs are all collected at slightly above Sea Level
altitude. Be sure to reduce the derating for higher density altitude.
Output Current Limiting
Current limiting inception is defined as the point at which full power falls
below the rated tolerance. See the Performance/Functional Specifications.
Note particularly that the output current may briefly rise above its rated
value in normal operation as long as the average output power is not
exceeded. This enhances reliability and continued operation of your
application. If the output current is too high, the converter will enter the
short circuit condition.
Output Short Circuit Condition
When a converter is in current-limit mode, the output voltage will drop as
the output current demand increases. If the output voltage drops too low
(approximately 98% of nominal output voltage for most models), the
magnetically coupled voltage used to develop primary side voltages will
also drop, thereby shutting down the PWM controller. Following a time-out
period, the PWM will restart, causing the output voltage to begin ramping
up to its appropriate value. If the short-circuit condition persists, another
shutdown cycle will initiate. This rapid on/off cycling is called “hiccup
mode”. The hiccup cycling reduces the average output current, thereby
preventing excessive internal temperatures and/or component damage. A
short circuit can be tolerated indefinitely.
The “hiccup” system differs from older latching short circuit systems
because you do not have to power down the converter to make it restart.
The system will automatically restore operation as soon as the short circuit
condition is removed.
Output Over Voltage Protection
OV protection is active upon converter (ON).An OV condition
(>120%*Voset) would latch off permanently. The ON/OFF pin and PGOOD
pin are also latched low at this OV event. The latch condition can be reset
only by recycling Vin.
There is another non-latch OV protection (>113%*Voset). At the condition
the output over 113% OV, the converter will operate “sink” mode only until
the output drops below 87%*Voset. After the output drops below 87%, the
converter will operate “sink-source” mode (normal operation) again.
Output Under Voltage Protection
The under voltage protection is NOT enabled until the end of soft-start
condition. In a UV event, if the output drops below 87%*Voset due to some
reason for example OV, OC, OT and dynamic load response, the converter
will operate almost “source” mode only until UV condition is removed. (The
converter could operate sink mode in a very short time of switching cycles,
to avoid high negative voltage ringing until the UV condition removed.)
Output Voltage Sequencing
The OKY2 modules include a sequencing feature that enables users to
implement various types of output voltage sequencing in their applications.
This is accomplished via an additional sequencing pin. When not using the
sequencing feature, either tie the sequence pin to Vin or leave it
unconnected. When an analog voltage is applied to the sequence pin, the
output voltage tracks this voltage until the output reaches the set-point
voltage. The final value of the sequence voltage must be set higher than
the setpoint voltage of the module. The output voltage follows the voltage
on the sequence pin on a one-to-one volt basis. By connecting multiple
modules together, multiple modules can track their output voltages to the
voltage applied on the sequence pin. For proper voltage sequencing, fi rst,
input voltage is applied to the module. The On/Off pin of the module is left
unconnected (or tied to GND for negative logic modules or tied to Vin for
positive logic modules) so that the module is ON by default. After applying
input voltage to the module, a minimum 10msec delay is required before
applying voltage on the sequence pin. During this time, a voltage of 100mV
(± 20 mV) is maintained on the sequence pin. This delay gives the module
enough time to complete its internal power-up soft-start cycle. During the
delay time, the sequence pin should be held close to ground (nominally
100mV ± 20 mV). This is required to keep the internal op-amp out of
saturation thus preventing output overshoot during the start of the
sequencing ramp.
Remote On/Off Control
The remote On/Off Control can be ordered with either polarity. Please refer
to the Connection Diagram on page 1 for On/Off connections.
Positive logic models are enabled when the On/Off pin is left open or is
pulled high to +Vin with respect to -Vin. An internal bias current causes
the open pin to rise to +Vin. Positive-polarity devices are disabled when
the On/Off is grounded or brought to within a low voltage (see
Specifications) with respect to -Vin.
Negative logic devices are on (enabled) when the On/Off is open or brought
to within a low voltage (see Specifications) with respect to -Vin. The device
is off (disabled) when the On/Off is pulled high with respect to -Vin (see
specifications).
Dynamic control of the On/Off function should be able to sink appropriate
signal current when brought low and withstand appropriate voltage when
brought high. Be aware too that there is a finite time in milliseconds (see
Specifications) between the time of On/Off Control activation and stable,
regulated output. This time will vary slightly with output load type and
current and input conditions.
Output Capacitive Load
These converters do not require external capacitance added to achieve
rated specifications. Users should only consider adding capacitance to
reduce switching noise and/or to handle spike current load steps. Install
only enough capacitance to achieve noise objectives. Excess external
capacitance may cause regulation problems, degraded transient response
and possible oscillation or instability.
Synchronization (OKY2-T/60-W12NA-C & OKY2-T/60-W12PA-C only)
These converters can be synchronized using an external signal. Details of
the SYNC signal are provided in the Performance and Functional Specifi
cations table. If the synchronization function is not being used, leave the
SYNC pin floating. When synchronization function is used, output ripple
may increase on some operating conditions. Please check the proper
operation of this device with the peripheral circuits on your system.
www.murata-ps.com/support
MDC_OKY2-T/60-W12.A01 Page 12 of 15
OKY2-T/60-W12 Series
Programmable Output 60-Amp SMT PoL
CLKOUT (OKY2-T/60-W12NA-C & OKY2-T/60-W12PA-C only)
Square wave with switching frequency is appeared CLKOUT pin. It is
possible to synchronize other converters by connecting CLKOUT pin to
SYNC pin of other converter. Details of the CLKOUT signal are provided in
the Performance and Functional Specifications table. If the CLKOUT
function is not being used, leave the CLKOUT pin floating.
Soldering Guidelines
Murata recommends the specifications below when installing these
converters. These specifications vary depending on the solder type.
Exceeding these specifications may cause damage to the product. Your
production environment may differ therefore please thoroughly review
these guidelines with your process engineers.
Reflow Solder Operations for surface-mount products (SMT)
For Sn/Ag/Cu based solders:
Preheat Temperature
Less than 1°C per second
Time over Liquidus
45 to 75 seconds
Maximum Peak Temperature 260°C
Cooling Rate
Less than 3°C per second
For Sn/Pb based solders:
Preheat Temperature
Less than 1°C per second
Time over Liquidus
60 to 75 seconds
Maximum Peak Temperature 235°C
Cooling Rate
Less than 3°C per second
Output Voltage Adjustment
The output voltage may be adjusted over a limited range by connecting an
external trim resistor (Rtrim) between the +Trim pin and –Trim pin. The
Rtrim resistor must be a 1/10 Watt precision metal film type,±0.5%
accuracy or better with low temperature coefficient, ±100 ppm/°C. or
better. Mount the resistor close to the converter with very short leads or
use a surface mount trim resistor.
In the table below, the calculated resistance is given. Do not exceed the
specified limits of the output voltage or the converter’s maximum power
rating when applying these resistors. Also, avoid high noise at the -Trim
input. However, to prevent instability, you should never connect any
capacitors to –Trim pin.
Output Voltage
Calculated Rtrim (kΩ)
2.0 V.
10.80
1.8 V.
12.70
1.5 V.
17.50
1.2 V.
28.00
1.0 V.
46.60
0.70 V.
(open)
Resistor Trim Equation, OKY2-T/60-W12 models
(kΩ) =
Vout
0.7
Recommended Lead-free Solder Reflow Profile
www.murata-ps.com/support
MDC_OKY2-T/60-W12.A01 Page 13 of 15
OKY2-T/60-W12 Series
Programmable Output 60-Amp SMT PoL
PARALLEL OPERATION
NOTES:

The OKY2-T/60-W12N-C and OKY2-T/60-W12P-C can operate in parallel (up to 2 converters) without the SYNC function, by connecting each
ISHARE, SEQ and ON/OFF terminals.

The OKY2-T/60-W12NA-C and OKY2-T/60-W12PA-C can operate in parallel (up to 3 converters) with the SYNC function, by connecting each
ISHARE, SEQ, ON/OFF, SYNC and CLKOUT terminals.
(1)
(2)
(3)
(4)
(5)
(6)
When using parallel operation, the temperature of some parts may increase in one of the products because there are some differences in the
operating conditions between the first and second module. For this reason, please check the temperature of the products in your application.
When using parallel operation, please set no more than 80% of the sum of individual products because the current of each product may not be equal.
It is necessary to install Cin and Cout for each module.
To avoid OC, OV and UV protection malfunction, please set same values of Vout of each module and place each modules isometric alignment
for Vin and Load. And it is recommended that the load may be started after PGOOD signal “High” because of same reason.
Parallel operation can be available among same parts N.O. only.
There is no redundancy function.
Below is the recommended schematic diagram for parallel operation without the SYNC function:
(OKY2-T/60-W12N-C and OKY2-T/60-W12P-C only)
NOTE: Please shield well from any noise, especially SHARE, SEQ, VS+, VS- and ON/OFF lines to avoid any unexpected interference during operation.
www.murata-ps.com/support
MDC_OKY2-T/60-W12.A01 Page 14 of 15
OKY2-T/60-W12 Series
Programmable Output 60-Amp SMT PoL
Below is the recommended schematic diagram for parallel operation with the SYNC function:
(OKY2-T/60-W12NA-C and OKY2-T/60-W12PA-C only)
(1)
(2)
Please shield well from any noise, especially SHARE, SEQ, VS+, VS- and ON/OFF lines, to avoid any unexpected interference during operation.
Be careful for drawing of SYNC-CLKOUT line, because CLKOUT lines have large amplitude of square wave form.
SYNC 1st Module VS- GND Cin for 1st Module
Cout for 1st Module
Vin Vout
ON/OFF VS+ SEQ +Trim
PGOOD Share CLKOUT -Trim Rtrim SYNC 2nd Module Cin for 2nd Module
GND Vin RL R1 Vout
ON/OFF SEQ Vin VS- Cout for 2nd Module
VS+ +Trim
PGOOD Rtrim Share CLKOUT -Trim
3rd Module Share SYNC +Trim
Rtrim PGOOD -Trim
SEQ VS+ ON/OFF Vout
Vin Cin for 3rd Module
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
GND Cout for 3rd Module
CLKOUT VS- This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2016 Murata Power Solutions, Inc.
www.murata-ps.com/support
MDC_OKY2-T/60-W12.A01 Page 15 of 15