DPFX-100-TR DATA SHEET Two (2) fibers Detachable DisplayPort Extender, DPFX-100-TR Contents Description Features Applications Technical Specifications Operating Conditions Drawing of Module Drawing of Cable Connection HDMI Pin Description Reliability Test Laser Safety Information OPTICIS HQ Opticis Co., Ltd. # 16Fl, Kins Tower Jeongja 331, 8 Sungnam-daero, Bundang-gu Sungnam-si, Gyunggi-do, 463-782 South Korea Te l: +82 (31) 719-8033 Fax: +82 (31) 719-8032 www.opticis.com [email protected] Copyright © 2014, All rights reserved by Opticis Nov. 6, 2014 DPFX-100-TR Description New optical DisplayPort DPFX extender, DPFX-100-TR consists of transmitter module and receiver module, each of which has Two (2) LC fibers connection and is designed compact enough to be fitted into various installation environments. It enables to transmit WQXGA (2560x1600) at 60Hz and 4K at 30Hz signal up to 200m (656feet), avoiding any tricks like scaling or data compression for lessening a burden of data transmission. It provides total data throughput 10.8Gbps (2.7Gbps per lane). The pure fiber connection by two (2) LC fibers connector between transmitter and receiver, gives clean, secure and easy installation with perfect electrical isolation, but without electrical hazard and interference. The DPFX-100-TR can be operated by USB power without external DC power adapter by plugging the supplied USB to DC plug cables to each module. In shipping group, two (2) short DP cables are also included so as to be mated to various types of DP connectors. The shipping items are shown as follows; 1) One (1) Transmitter (Tx) and One (1) Receiver (Rx) 2) Two (2) DC +5V 1A power adapters 3) Two (2) DP cables (0.5m) 4) Two (2) USB to DC plug cables 4) User’s Manual ※ Other options – contact with sales office Copyright © 2014, All rights reserved by Opticis Nov. 6, 2014 DPFX-100-TR Features Supports DisplayPort 1.1a standards Extends WQXGA (2560x1600) at 60Hz and 4K at 30Hz Transmits DP data up to 200m (656feet) over two (2) LC multi-mode fibers (50/125um). Offers total data rate 10.8Gbps (2.7Gbps per lane) Supports auxiliary channel Compact design allows direct connect to the DP display Has DP receptacle and provides intermediate cable for flexible installation Operated by USB power or DC power supplier Data security with negligible EMI emission. Includes two (2) +5V, 1A DC power adapters / two (2) USB to DC plug cables for the transmitter and receiver Certification: CE / FCC, UL IT, Laser Safety class 1 Applications Medical imaging Military Control room Simulator Copyright © 2014, All rights reserved by Opticis Nov. 6, 2014 DPFX-100-TR Technical Specifications Parameter Laser Diodes in Tx Module Components Electrical Optical Mechanical Connect Specifications Photo Diodes in Rx Module Input and Output Signals Data Transfer Rate (Graphic Data) Total Jitter at the end of Rx output Skew inter-channels Link Power Budget Module dimension (WDH) Optical Connector Electric Connector Type from Systems and to Displays Recommended Fiber Multi-mode VCSEL (Vertical Cavity Surface Emitting Laser) PIN-PD ANSI 8B/10 Level (complying with DP1.1a) Max. 2.7Gbps Max. 0.49UI Max. 6ns Min 9.4dB 35 x 72 x 16mm Duplex LC connectors 20pin DP Receptacle Connector 50/125 um Multi-mode Glass Fiber Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only. Functional operation of the device is not implied at these of any other conditions in excess of those given in the operational sections of the datasheet. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability. Parameter Symbol Min Max Unit Supply Adapter Voltage VCC - 6.5 V Operating Temperature TOP 0 50 Operating Relative Humidity RHOP 10 85 Storage Temperature Tstg -30 70 Storage Relative Humidity RHstg 10 95 1) 2) ° C %RH ° C %RH Note 1), 2) Under the conditions of No drops of dew Copyright © 2014, All rights reserved by Opticis Nov. 6, 2014 DPFX-100-TR Operating Conditions Transmitter module: DPFX-100-T Parameter Power Supply DATA ANSI 8b/10b Supply Voltage Supply Current Power Dissipation Power Supply (Note1) Data Output Load Symbol Minimum Typical Maximum Units Vcc ITCC PTX PSR 4.5 230 1.04 5.0 280 1.40 5.5 330 1.82 V mA W Rejection RLD Transmitter Differential Input Voltage Swing (Peak-to-Peak) Optical Link (Note3) Output Optical Power Wavelength Spectral width in RMS Relative Intensity of (Note2) Extinction Ratio VID Po Noise Rising/Falling Time Jitter in p-p value (Note3) 0.4 50 mVp-p 50 Ω 1.6 850 RIN VID V 1 990 3 dBm nm nm -20 Ext dB/Hz 4 dB Trise/Tfall Tjitter 260 260 ps ps Note1. Tested with a 50mVp-p sinusoidal signal in the frequency range from 500 Hz to 500 MHz on the V CC supply with the recommended power supply filter in place. Typically less than a 0.25 dB change in sensitivity is experienced. Note2. Measure in 1GHz of frequency bandwidth Note3. Use PPG (Pulse Pattern Generator) source with jitter 50ps Receiver module: DPFX-100-R Parameter Power Supply DATA ANSI 8b/10b Supply Voltage Supply Current Power Dissipation Power Supply (Note4) Data Input Load Symbol Rejection Vcc IRCC PRX PSR Minimum Typical Maximum Units 4.5 330 1.49 5.0 380 1.90 5.5 430 2.37 V mA W RLD Receiver Data Output Voltage Swing (Peak-to-Peak) Optical Link (Note9) Receiving Optical Power Receiving Wavelength Signal_Detect Good Signal_Detect Fail Link Power Budget Total Jitter (note 5) VODp-p Po SDg SDf Pbgt TRjitter -11 850 50 mVp-p 50 Ω 600 mVp-p 1 990 -15 -23 9.45 0.49 dBm nm dBm dBm dB UI Note4. Tested with a 50mVp-p sinusoidal signal in the frequency range from 500 Hz to 500 MHz on the V CC supply with the recommended power supply filter in place. Typically less than a 0.25 dB change in sensitivity is experienced. Note5. It is measured as total jitters including Tx and Rx modules under maximum extension, 200 meters with 2.7Gbps. Recommended specifications of fiber-optic cable Parameters Conditions Fiber Type Modal Bandwidth Fiber Cable Attenuation Extension Distance No. of Ferrules Skew Insertion Attenuation Total Optical Attenuation = 850nm = 850nm Duplex LC In 330 ft (100 meter) extension Copyright © 2014, All rights reserved by Opticis Specifications 50m Multi-mode Graded Index Glass Fiber Min. 500 MHz km Max. 2.5dB/km 10 – 1650ft (500 meters) 2 ferrule Max. 0.4ns Max. 0.5dB Max. 1.5dB Nov. 6, 2014 DPFX-100-TR Drawing of Module Note: The transmitter, DPFX-100-T and the receiver, DPFX-100-R have the same mechanical dimensions Drawing of Cable Connection Copyright © 2014, All rights reserved by Opticis Nov. 6, 2014 DPFX-100-TR DisplayPort Pin Description TX Module Pin Symbol 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 ML_Lane0(p) GND ML_Lane0(n) ML_Lane1(p) GND ML_Lane1(n) ML_Lane2(p) GND ML_Lane2(n) ML_Lane3(p) GND ML_Lane3(n) CONFIG1 CONFIG2 AUX CH(p) GND AUX CH(n) Hot Plug Detect Return DP_PWR Mating Row Contact Location Top Bottom Top Bottom Top Bottom Top Bottom Top Bottom Top Bottom Top Bottom Top Bottom Top Bottom Top Bottom Functional Description Displayport Data Lane0 Positive Ground Displayport Data Lane0 Negative Displayport Data Lane1 Positive Ground Displayport Data Lane1 Negative Displayport Data Lane2 Positive Ground Displayport Data Lane2 Negative Displayport Data Lane3 Positive Ground Displayport Data Lane3 Negative Cable Adaptor Detect None Displayport Aux Channel Positive Ground Displayport Aux Channel Negative HPD is used to detect a sink device by the source device None None RX Module Pin Symbol 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 ML_Lane3(n) GND ML_Lane3(p) ML_Lane2(n) GND ML_Lane2(p) ML_Lane1(n) GND ML_Lane1(p) ML_Lane0(n) GND ML_Lane0(p) CONFIG1 CONFIG2 AUX CH(p) GND AUX CH(n) Hot Plug Detect Return DP_PWR Mating Row Contact Location Top Bottom Top Bottom Top Bottom Top Bottom Top Bottom Top Bottom Top Bottom Top Bottom Top Bottom Top Bottom Functional Description Displayport Data Lane3 Negative Ground Displayport Data Lane3 Positive Displayport Data Lane2 Negative Ground Displayport Data Lane2 Positive Displayport Data Lane1 Negative Ground Displayport Data Lane1 Positive Displayport Data Lane0 Negative Ground Displayport Data Lane0 Positive Cable Adaptor Detect None Displayport Aux Channel Positive Ground Displayport Aux Channel Negative HPD is used to detect a sink device by the source device None Power for Connector (3.3V 500mA) Copyright © 2014, All rights reserved by Opticis Nov. 6, 2014 DPFX-100-TR Copyright © 2014, All rights reserved by Opticis Nov. 6, 2014